High-performance flexible pressure sensors have garnered significant attention in fields such as wearable electronics and human-machine interfaces.However,the development of flexible pressure sensors that simultaneous...High-performance flexible pressure sensors have garnered significant attention in fields such as wearable electronics and human-machine interfaces.However,the development of flexible pressure sensors that simultaneously achieve high sensitivity,a wide detection range,and good mechanical stability remains a challenge.In this paper,we propose a flexible piezoresistive pressure sensor based on a Ti_(3)C_(2)Tx(MXene)/polyethylene oxide(PEO)composite nanofiber membrane(CNM).The sensor,utilizing MXene(0.4 wt%)/PEO(5 wt%),exhibits high sensitivity(44.34 kPa^(−1)at 0−50 kPa,12.99 kPa^(−1)at 50−500 kPa)and can reliably monitor physiological signals and other subtle cues.Moreover,the sensor features a wide detection range(0−500 kPa),fast response and recovery time(~150/45 ms),and excellent mechanical stability(over 10000 pressure cycles at maximum load).Through an MXene/PEO sensor array,we demonstrate its applications in human physiological signal monitoring,providing a reliable way to expand the application of MXene-based flexible pressure sensors.展开更多
基金support from Beijing Natural Science Foundation−Xiaomi Innovation Joint Fund(Grant No.L233009)the National Natural Science Foundation of China(NSFC Grant Nos.62422409,62174152 and 62374159)from the Youth Innovation Promotion Association of Chinese Academy of Sciences(Grant No.2020115).
文摘High-performance flexible pressure sensors have garnered significant attention in fields such as wearable electronics and human-machine interfaces.However,the development of flexible pressure sensors that simultaneously achieve high sensitivity,a wide detection range,and good mechanical stability remains a challenge.In this paper,we propose a flexible piezoresistive pressure sensor based on a Ti_(3)C_(2)Tx(MXene)/polyethylene oxide(PEO)composite nanofiber membrane(CNM).The sensor,utilizing MXene(0.4 wt%)/PEO(5 wt%),exhibits high sensitivity(44.34 kPa^(−1)at 0−50 kPa,12.99 kPa^(−1)at 50−500 kPa)and can reliably monitor physiological signals and other subtle cues.Moreover,the sensor features a wide detection range(0−500 kPa),fast response and recovery time(~150/45 ms),and excellent mechanical stability(over 10000 pressure cycles at maximum load).Through an MXene/PEO sensor array,we demonstrate its applications in human physiological signal monitoring,providing a reliable way to expand the application of MXene-based flexible pressure sensors.