期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Implementation of a double trigger condition system based on charge comparison and TOF measurement for the NEDA detector array
1
作者 J.M.Deltoro A.Goasduff +19 位作者 F.J.Egea V.González A.Gadea R.M.Pérez-Vidal I.Lazarus M.Kogimtzis L.McNicholl M.Palacz G.Jaworski J.J.Valiente-Dobón J.Nyberg S.Casans A.E.Navarro-Antón E.Sanchis A.Boujrad E.Clément T.Hüyük R.Illicachi O.Stezowski V.Modamio 《Nuclear Science and Techniques》 2025年第2期40-48,共9页
The NEutron Detector Array(NEDA)is designed to be coupled to gamma-ray spectrometers to enhance the sensitivity of the setup by enabling reaction channel selection through counting of the evaporated neutrons.This arti... The NEutron Detector Array(NEDA)is designed to be coupled to gamma-ray spectrometers to enhance the sensitivity of the setup by enabling reaction channel selection through counting of the evaporated neutrons.This article presents the implementation of a double trigger condition system for NEDA,which improves the acquisition of neutrons and reduces the number of gamma rays acquired.Two independent triggers are generated in the double trigger condition system:one based on charge comparison(CC)and the other on time-of-flight(TOF).These triggers can be combined using OR and AND logic,offering four distinct trigger modes.The developed firmware is added to the previous one in the Virtex 6 field programmable gate array(FPGA)present in the system,which also includes signal processing,baseline correction,and various trigger logic blocks.The performance of the trigger system is evaluated using data from the E703 experiment performed at GANIL.The four trigger modes are applied to the same data,and a subsequent offline analysis is performed.It is shown that most of the detected neutrons are preserved with the AND mode,and the total number of gamma rays is significantly reduced.Compared with the CC trigger mode,the OR trigger mode allows increasing the selection of neutrons.In addition,it is demonstrated that if the OR mode is selected,the online CC trigger threshold can be raised without losing neutrons. 展开更多
关键词 Neutron detector Neutron-gamma discrimination pulse shape analysis TIME-OF-FLIGHT Charge comparison
在线阅读 下载PDF
Identification of anomalous fast bulk events in a p-type point-contact germanium detector 被引量:6
2
作者 Ren-Ming-Jie Li Shu-Kui Liu +13 位作者 Shin-Ted Lin Li-Tao Yang Qian Yue Chang-Hao Fang Hai-Tao Jia Xi Jiang Qian-Yun Li Yu Liu Yu-Lu Yan Kang-Kang Zhao Lei Zhang Chang-Jian Tang Hao-Yang Xing Jing-Jun Zhu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第5期53-67,共15页
The ultralow detection threshold,ultralow intrinsic background,and excellent energy resolution of ptype point-contact germanium detectors are important for rare-event searches,in particular for the detection of direct... The ultralow detection threshold,ultralow intrinsic background,and excellent energy resolution of ptype point-contact germanium detectors are important for rare-event searches,in particular for the detection of direct dark matter interactions,coherent elastic neutrino-nucleus scattering,and neutrinoless double beta decay.Anomalous bulk events with an extremely fast rise time are observed in the CDEX-1B detector.We report a method of extracting fast bulk events from bulk events using a pulse shape simulation and reconstructed source experiment signature.Calibration data and the distribution of X-rays generated by intrinsic radioactivity verified that the fast bulk experienced a single hit near the passivation layer.The performance of this germanium detector indicates that it is capable of single-hit bulk spatial resolution and thus provides a background removal technique. 展开更多
关键词 p-type point-contact germanium detector Dark matter pulse shape analysis Anomalous fast bulk events
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部