Angle of Attack(AOA) is a crucial parameter which directly affects the aerodynamic forces of an aircraft.The measurement of AOA is required to ensure a safe flight within its designed flight envelop.This paper intends...Angle of Attack(AOA) is a crucial parameter which directly affects the aerodynamic forces of an aircraft.The measurement of AOA is required to ensure a safe flight within its designed flight envelop.This paper intends to summarise a comprehensive survey on the measurement techniques and estimation methods for AOA, specifically in Unmanned Aerial Vehicle(UAV) applications.In the case of UAVs, weight constraint plays a major role as far as sensor suites are concerned.This results in selecting a suitable estimation method to extract AOA using the available data from the autopilot.The most feasible and widely employed AOA measurement technique is by using the Multi-Hole Probes(MHPs).The MHP measures the AOA regarding the pressure variations between the ports.Due to the importance of MHP in AOA measurement, the calibration methods for the MHP are also included in this paper.This paper discusses the AOA measurement using virtual AOA sensors, their importance and the operation.展开更多
Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of th...Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of the needle tip and the ultrasound probe as two independent processes,lacking an integrated calibration mechanism,which often leads to cumulative errors and reduced spatial consistency.To address this challenge,we propose a joint calibration model that unifies the calibration of the surgical needle tip and the ultrasound probe within a single coordinate system.The method formulates the calibration process through a series of mathematical models and coordinate transformation models and employs a gradient descent based optimization to refine the parameters of these models.By establishing and iteratively optimizing a template coordinate system through modeling of constrained spherical motion,the proposed joint calibration model achieves submillimeter accuracy in needle tip localization.Building upon this,an N line based calibration model is developed to determine the spatial relationship between the probe and the ultrasound image plane,resulting in an average pixel deviation of only 1.2373 mm.Experimental results confirm that this unified modeling approach effectively overcomes the limitations of separate calibration schemes,significantly enhancing both precision and robustness,and providing a reliable computational model for surgical navigation systems that require high spatial accuracy without relying on ionizing radiation.展开更多
Purpose A new in-vacuum three-dimensional Hall probe magnetic measurement system is under fabrication for characterizing the magnetic performance of the Cryogenic Permanent Magnet Undulator(CPMU).In order to fit the s...Purpose A new in-vacuum three-dimensional Hall probe magnetic measurement system is under fabrication for characterizing the magnetic performance of the Cryogenic Permanent Magnet Undulator(CPMU).In order to fit the small gap(5 mm)of magnetic structure and vacuum environment,a small three-dimensional Hall probe has been manufactured.The angular and positional misalignment errors of the Hall sensors play an important role in the measurement accuracy of the CPMU.In order to minimize the misalignment errors,a method of calibrating angle error and relative assembly displacements of a three-dimensional Hall probe is carried out.Methods The angle error of Hall sensors will be calibrated by a standard dipole magnet and a five-dimensional Hall bench.The standard dipole magnet will generate a single direction and uniform magnetic field.And the fivedimensional Hall bench is used to rotate the Hall probe which is put in the center of magnet.Based on the relationship between angle and magnetic field strength,the angle error of each Hall sensor will be obtained.The relative position between the sensitive areas of the Hall sensors will be calibrated by a two-dimensional magnetic field undulator section.Based on Maxwell’s equations,through the calculation of measurement magnetic field strength,the relative assembly displacements of the three Hall sensors can be derived.Results The details of the calibration methods and the data processing of angle error and relative assembly displacements of a three-dimensional Hall probe are presented.The three-dimensional magnetic fields of a cryogenic permanent magnet undulator can be received accurately by correcting these angle errors and position errors of Hall sensors.Conclusions This paper illustrates the relative position and angle calibration procedures and the data processing of a three-dimensional Hall probe.Now the design of a smaller Hall probe is in process.The calibration of the angle errors and position errors will be carried out after the fabrication of the standard dipole magnet.展开更多
基金the financial support of the Aeronautical Research&Development Board(AR&DB)through the SIGMA Panel for sanctioning the project ID number ARDB/01/2021791/M/I。
文摘Angle of Attack(AOA) is a crucial parameter which directly affects the aerodynamic forces of an aircraft.The measurement of AOA is required to ensure a safe flight within its designed flight envelop.This paper intends to summarise a comprehensive survey on the measurement techniques and estimation methods for AOA, specifically in Unmanned Aerial Vehicle(UAV) applications.In the case of UAVs, weight constraint plays a major role as far as sensor suites are concerned.This results in selecting a suitable estimation method to extract AOA using the available data from the autopilot.The most feasible and widely employed AOA measurement technique is by using the Multi-Hole Probes(MHPs).The MHP measures the AOA regarding the pressure variations between the ports.Due to the importance of MHP in AOA measurement, the calibration methods for the MHP are also included in this paper.This paper discusses the AOA measurement using virtual AOA sensors, their importance and the operation.
基金Support by Sichuan Science and Technology Program[2023YFSY0026,2023YFH0004].
文摘Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of the needle tip and the ultrasound probe as two independent processes,lacking an integrated calibration mechanism,which often leads to cumulative errors and reduced spatial consistency.To address this challenge,we propose a joint calibration model that unifies the calibration of the surgical needle tip and the ultrasound probe within a single coordinate system.The method formulates the calibration process through a series of mathematical models and coordinate transformation models and employs a gradient descent based optimization to refine the parameters of these models.By establishing and iteratively optimizing a template coordinate system through modeling of constrained spherical motion,the proposed joint calibration model achieves submillimeter accuracy in needle tip localization.Building upon this,an N line based calibration model is developed to determine the spatial relationship between the probe and the ultrasound image plane,resulting in an average pixel deviation of only 1.2373 mm.Experimental results confirm that this unified modeling approach effectively overcomes the limitations of separate calibration schemes,significantly enhancing both precision and robustness,and providing a reliable computational model for surgical navigation systems that require high spatial accuracy without relying on ionizing radiation.
文摘Purpose A new in-vacuum three-dimensional Hall probe magnetic measurement system is under fabrication for characterizing the magnetic performance of the Cryogenic Permanent Magnet Undulator(CPMU).In order to fit the small gap(5 mm)of magnetic structure and vacuum environment,a small three-dimensional Hall probe has been manufactured.The angular and positional misalignment errors of the Hall sensors play an important role in the measurement accuracy of the CPMU.In order to minimize the misalignment errors,a method of calibrating angle error and relative assembly displacements of a three-dimensional Hall probe is carried out.Methods The angle error of Hall sensors will be calibrated by a standard dipole magnet and a five-dimensional Hall bench.The standard dipole magnet will generate a single direction and uniform magnetic field.And the fivedimensional Hall bench is used to rotate the Hall probe which is put in the center of magnet.Based on the relationship between angle and magnetic field strength,the angle error of each Hall sensor will be obtained.The relative position between the sensitive areas of the Hall sensors will be calibrated by a two-dimensional magnetic field undulator section.Based on Maxwell’s equations,through the calculation of measurement magnetic field strength,the relative assembly displacements of the three Hall sensors can be derived.Results The details of the calibration methods and the data processing of angle error and relative assembly displacements of a three-dimensional Hall probe are presented.The three-dimensional magnetic fields of a cryogenic permanent magnet undulator can be received accurately by correcting these angle errors and position errors of Hall sensors.Conclusions This paper illustrates the relative position and angle calibration procedures and the data processing of a three-dimensional Hall probe.Now the design of a smaller Hall probe is in process.The calibration of the angle errors and position errors will be carried out after the fabrication of the standard dipole magnet.