期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Shape control on probability density function in stochastic systems 被引量:5
1
作者 Lingzhi Wang Fucai Qian Jun Liu 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2014年第1期144-149,共6页
A novel strategy of probability density function (PDF) shape control is proposed in stochastic systems. The control er is designed whose parameters are optimal y obtained through the improved particle swarm optimiza... A novel strategy of probability density function (PDF) shape control is proposed in stochastic systems. The control er is designed whose parameters are optimal y obtained through the improved particle swarm optimization algorithm. The parameters of the control er are viewed as the space position of a particle in particle swarm optimization algorithm and updated continual y until the control er makes the PDF of the state variable as close as possible to the expected PDF. The proposed PDF shape control technique is compared with the equivalent linearization technique through simulation experiments. The results show the superiority and the effectiveness of the proposed method. The control er is excellent in making the state PDF fol ow the expected PDF and has the very smal error between the state PDF and the expected PDF, solving the control problem of the PDF shape in stochastic systems effectively. 展开更多
关键词 stochastic systems probability density function (PDF) shape control improved particle swarm optimization.
在线阅读 下载PDF
Controlling the probability density of quantum systems
2
作者 Yifan Xing Jun Wu 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2011年第6期975-981,共7页
A new method to design a quantum controller which directly controls the probability density function(PDF) of quantum systems is proposed.Based on the quantum model from the PDF perspective,two specific control algor... A new method to design a quantum controller which directly controls the probability density function(PDF) of quantum systems is proposed.Based on the quantum model from the PDF perspective,two specific control algorithms are proposed with uniform and non-uniform fields,respectively.Then a detailed control algorithm with convergence analysis is given for the small error case.By appropriately estimating the selected Lyapunov function,more accurate control effect is achieved.The proposed scheme provides a constructive method to find appropriate parameters for controller design. 展开更多
关键词 quantum control probability density control stochastic distribution control.
在线阅读 下载PDF
State and Mode Feedback Control for Discrete-time Markovian Jump Linear Systems With Controllable MTPM 被引量:1
3
作者 Jin Zhu Qin Ding +1 位作者 Maksym Spiryagin Wanqing Xie 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第3期830-837,共8页
In this note, the state and mode feedback control problems for a class of discrete-time Markovian jump linear systems(MJLSs) with controllable mode transition probability matrix(MTPM) are investigated. In most achieve... In this note, the state and mode feedback control problems for a class of discrete-time Markovian jump linear systems(MJLSs) with controllable mode transition probability matrix(MTPM) are investigated. In most achievements, controller design of MJLSs pays more attention to state/output feedback control for stability, while the system cost in practice is out of consideration. In this paper, we propose a control mechanism consisting of two parts: finite-path-dependent state feedback controller design with which uniform stability of MJLSs can be ensured, and mode feedback control which aims to decrease system cost. Differing from the traditional state/output feedback controller design, the main novelty is that the proposed control mechanism not only guarantees system stability, but also decreases system cost effectively by adjusting the occurrence probability of system modes. The effectiveness of the proposed mechanism is illustrated via numerical examples. 展开更多
关键词 controllable mode transition probability matrix(MTPM) Markovian jump linear systems(MJLSs) STABILIZATION system cost
在线阅读 下载PDF
Impact of dose calculation algorithm on radiation therapy 被引量:1
4
作者 Wen-Zhou Chen Ying Xiao Jun Li 《World Journal of Radiology》 CAS 2014年第11期874-880,共7页
The quality of radiation therapy depends on the ability to maximize the tumor control probability while minimizing the normal tissue complication probability.Both of these two quantities are directly related to the ac... The quality of radiation therapy depends on the ability to maximize the tumor control probability while minimizing the normal tissue complication probability.Both of these two quantities are directly related to the accuracy of dose distributions calculated by treatment planning systems.The commonly used dose calculation algorithms in the treatment planning systems are reviewed in this work.The accuracy comparisons among these algorithms are illustrated by summarizing the highly cited research papers on this topic.Further,the correlation between the algorithms and tumor control probability/normal tissue complication probability values are manifested by several recent studies from different groups.All the cases demonstrate that dose calculation algorithms play a vital role in radiation therapy. 展开更多
关键词 Dose calculation ALGORITHM Radiation therapy Tumor control probability Normal tissue complication probability
暂未订购
Evaluation of the systematic set-up errors using electronic portal image device in the radiotherapy procedures
5
作者 Ehab M. Attalla Rizk Abd El Moneam +2 位作者 Aida R. Tolba Maha H.Mokhtar Medhat W. Ismail 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第9期439-442,共4页
Objective: The aim of this work was to quantify the extent of set-up errors to conduct a quality assurance (QA) aspect of treatment delivery, verification of the treatment field's position on different days using ... Objective: The aim of this work was to quantify the extent of set-up errors to conduct a quality assurance (QA) aspect of treatment delivery, verification of the treatment field's position on different days using electronic portal. Methods: This study was carried out on 12 patients, treated for pelvis tumor; and total of 240 images obtained by electronic portal image device (EPID) were analyzed. The EPIs acquire using EPID attached to the Siemens linear accelerator. The anatomy match- ing software (Theraview) was used and displacement in two dimensions were noted for each treatment field to study patient setup errors. Results: The percentages of mean deviations less than 5 mm in X direction were 65% & 92%, from 5-10 mm were 31% & 19% and more than 10 mm were 11% & 9% forNP and lateral direction respectively. The percentages of mean deviations less than 5 mm in Y direction were 65% & 63%, from 5-10 mm were 33% & 28% and more than 10 mm were 22% & 29%. The mean deviations in 2D-vector errors were 〈 5 mm in 47% and 46%, 5-10 mm in 36% and 37% and 〉 10 mm in 37% and 37% of images in the NP and lateral direction respectively. Conclusion: The results revealed that the ranges of set up errors are immobilization method to improve reproducibility. The observed variations were not within the limits.. 展开更多
关键词 electronic portal imaging device (EPID) setup errors tumor control probability
暂未订购
ROC Analysis in Radiotherapy:A TCP Model-Based Test
6
作者 Mairon M.Santos Ubiraci P.C.Neves 《Open Journal of Applied Sciences》 2013年第2期186-193,共8页
Several mathematical models have been proposed to describe the dynamics of irradiated cancer cells and to evaluate the tumour control probability (TCP). In this article, we propose a TCP model-based statistical test f... Several mathematical models have been proposed to describe the dynamics of irradiated cancer cells and to evaluate the tumour control probability (TCP). In this article, we propose a TCP model-based statistical test for predicting the outcome of a radiation treatment. We determine the foresight capability of prostate tumour erradication (cure) from Monte Carlo simulations of the Dawson-Hillen TCP model. We construct the receiver operating characteristic (ROC) curves of the test from the probability distributions of the fraction of remaining tumour cells for simulated experiments that evolve either to cure or non-cure. Simulations show that a similar procedure may be applicable to clinical data. Results suggest that the evaluation of tumour sizes after the treatment has started may be used for short-term prognosis. 展开更多
关键词 Prostate Cancer RADIOTHERAPY Tumour control probability Hypothesis Test ROC Curve Dawson-Hillen Model Monte Carlo Simulation
暂未订购
上一页 1 下一页 到第
使用帮助 返回顶部