A fast configuration method for external cooling system of power transformer considering energy loss
1
作者 Lujia Wang Mengzhi Sun +2 位作者 Zhenlu Cai Haitao Yang Xibo Wu 《iEnergy》 2025年第4期269-277,共9页
Radiator cooling configurations need to account for both efficient heat dissipation and energy conservation requirements.Rapid and rational determination of cooling system configurations constitutes a critical aspect ... Radiator cooling configurations need to account for both efficient heat dissipation and energy conservation requirements.Rapid and rational determination of cooling system configurations constitutes a critical aspect of transformer design,enhancing electrical power energy utilization efficiency.Computational fluid dynamics(CFD)is widely recognized as a well-established technique for simulating and optimizing heat dissipation systems.However,this approach is time-consuming because of pre-processing procedures,such as meshing.This paper proposes a fast iterative optimization model for calculating the outlet oil temperature and airflow distribution.Based on the analytical model results,this paper identifies the optimal energy-saving range for radiator cooling configurations,incorporating the cooperative effects of cooling efficiency,air pressure drop during heat transfer,and inlet–outlet temperature difference.The analytical model demonstrated errors in energy dissipation and temperature difference calculations within an acceptable range.The calculation time was reduced by more than 99%.Radiator configurations within the optimal range effectively minimize energy waste while meeting the target temperature difference and enhancing cooling efficiency.Finally,the PC2600-22/520 radiator was utilized to validate the accuracy of the analytical model and the rationality of the co-optimal intervals. 展开更多
关键词 Power transformer oil temperature difference RADIATOR thermal efficiency air pressure drop
在线阅读 下载PDF
Memory-Fused Dual-Stream Fault Diagnosis Network Based on Transformer Vibration Signals
2
作者 Mingxing Wu Chengzhen Li +5 位作者 Xinyan Feng Fei Chen Yingchun Feng Huihui Song Wenyu Wang Faye Zhang 《Structural Durability & Health Monitoring》 2025年第6期1473-1487,共15页
As a core component of power systems, the operational status of transformers directly affects grid stability. To address the problem of “domain shift” in cross-domain fault diagnosis, this paper proposes a memory-en... As a core component of power systems, the operational status of transformers directly affects grid stability. To address the problem of “domain shift” in cross-domain fault diagnosis, this paper proposes a memory-enhanced dual-stream network (MemFuse-DSN). The method reconstructs the feature space by selecting and enhancing multi-source domain samples based on similarity metrics. An adaptive weighted dual-stream architecture is designed, integrating gradient reversal and orthogonality constraints to achieve efficient feature alignment. In addition, a novel dual dynamic memory module is introduced: the task memory bank is used to store high-confidence class prototype information, and adopts an exponential moving average (EMA) strategy to ensure the smooth evolution of prototypes over time;the domain memory bank is periodically updated and clusters potential noisy features, dynamically tracking domain shift trends, thereby optimizing the decoupled feature learning process. Experimental validation was conducted on a ±110 kV transformer vibration testing platform using typical fault types including winding looseness, core looseness, and compound faults. The results show that the proposed method achieves a fault diagnosis accuracy of 99.2%, providing a highly generalizable solution for the intelligent operation and maintenance of power equipment. 展开更多
关键词 Power transformer partial domain multi-source domain intelligent fault diagnosis
在线阅读 下载PDF
SIMULATING METHOD OF MAGNETIZING INRUSH CURRENT OF POWER TRANSFORMERS USING CONCEPT OF INSTANTANEOUS POWER
3
作者 贺家李 段玉倩 《Transactions of Tianjin University》 EI CAS 1999年第1期1-6,共6页
In this paper,a new simulating method is presented,using only the normal magnetizing curve (B-H) of the transformer core material,its geometric dimensions,the no-load power loss data and the concept of instantaneous p... In this paper,a new simulating method is presented,using only the normal magnetizing curve (B-H) of the transformer core material,its geometric dimensions,the no-load power loss data and the concept of instantaneous power. At the end of this paper the simulating calculation using EMTP has been also performed for the same transformer. The comparison shows that the two sets of results are very close to each other,and proves the correctness of the new method. The new method presented in this paper is helpful to verify the correctness of the power transformer design,analyze the behavior of the transformer protection under switching and study the new transformer protection principles. 展开更多
关键词 power transformer magnetizing inrush current remnant flue
在线阅读 下载PDF
Application of fuzzy analytic hierarchy process and neural network in power transformer risk assessment 被引量:8
4
作者 李卫国 俞乾 罗日成 《Journal of Central South University》 SCIE EI CAS 2012年第4期982-987,共6页
In operation,risk arising from power transformer faults is of much uncertainty and complicacy.To timely and objectively control the risks,a transformer risk assessment method based on fuzzy analytic hierarchy process(... In operation,risk arising from power transformer faults is of much uncertainty and complicacy.To timely and objectively control the risks,a transformer risk assessment method based on fuzzy analytic hierarchy process(FAHP) and artificial neural network(ANN) from the perspective of accuracy and quickness is proposed.An analytic hierarchy process model for the transformer risk assessment is built by analysis of the risk factors affecting the transformer risk level and the weight relation of each risk factor in transformer risk calculation is analyzed by application of fuzzy consistency judgment matrix;with utilization of adaptive ability and nonlinear mapping ability of the ANN,the risk factors with large weights are used as input of neutral network,and thus intelligent quantitative assessment of transformer risk is realized.The simulation result shows that the proposed method increases the speed and accuracy of the risk assessment and can provide feasible decision basis for the transformer risk management and maintenance decisions. 展开更多
关键词 fuzzy analytic hierarchy process risk assessment power transformer artificial neutral network
在线阅读 下载PDF
Application of extension method to fault diagnosis of transformer 被引量:4
5
作者 邓宏贵 曹建 +1 位作者 罗安 夏向阳 《Journal of Central South University of Technology》 EI 2007年第1期88-93,共6页
A novel extension diagnosis method was proposed for enhancing the diagnosis ability of the conventional dissolved gas analysis. Based on the extension theory a matter-element model was established for qualitatively an... A novel extension diagnosis method was proposed for enhancing the diagnosis ability of the conventional dissolved gas analysis. Based on the extension theory a matter-element model was established for qualitatively and quantitatively describing the fault diagnosis problem of power transformers. The degree of relation based on the dependent functions was employed to determine the nature and the grade of the faults in a transformer system. And the proposed method was verified with the experimental data. The results show that accuracy rate of the diagnosis method exceeds 90% and two kinds of faults can be detected at the same time. 展开更多
关键词 power transformer fault diagnosis extension theory matter-element model dependent function
在线阅读 下载PDF
Characteristics of the propagation of partial discharge ultrasonic signals on a transformer wall based on Sagnac interference 被引量:3
6
作者 Jun JIANG Kai WANG +2 位作者 Xuerui WU Guoming MA Chaohai ZHANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第2期10-18,共9页
The acoustic emission(AE)method has been widely recognized for the detection of incipient insulation fault phenomenon(partial discharge,PD)in power transfomiers,nevertheless,the installation and placement of AE sensor... The acoustic emission(AE)method has been widely recognized for the detection of incipient insulation fault phenomenon(partial discharge,PD)in power transfomiers,nevertheless,the installation and placement of AE sensors should be taken into full consideration.In this manuscript,a three-dimensional multiphysics model was established and simulated to research the characteristics of the propagation in the transformer wall.Furthermore,a piezoelectric transducer was used to detect PD ultrasonic signals and verify the simulation results in the laboratory.To ensure the accuracy of the detection,an optical fiber sensor based on the Sagnac interference principle was designed and adopted.The variation of the amplitude of the ultrasonic signal with distance reveals the characteristics of the ultrasonic signal propagating in the transformer wall.The distribution of sound pressure on the upper and lower surfaces of the simulation model proved that ultrasonic waves propagate in the form of symmetrical Lamb waves in the transformer wall.Moreover,the amplitude of the AE attenuates due to absorption and refraction loss,and local fluctuations on account of acoustic interference.Thus,a stable signal detected by an AE sensor does not represent the absence of PD in a transfomier.To improve the reliability of AE detection,it is proposed in this manuscript that repeated movement of the AE sensor is necessary to obtain a suitable measurement position.Similarly,it is necessary to adjust the position of the AE sensor in order to locate the PD source well.In addition,this study is expected to provide a theoretical analysis and a fiber sensor to address the problem of sensor placement in AE detection. 展开更多
关键词 partial discharge power transformer ultrasonic detection optical fiber Sagnac interference
在线阅读 下载PDF
Influence analysis of local heat source on internal temperature distribution of power transformer 被引量:3
7
作者 BAO Yanyan FENG Tingna +3 位作者 ZHANG Guangdong LIU Kang MA Jianqiao ZHOU Xiaodong 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2021年第2期218-225,共8页
Oil immersed power transformer is the main electrical equipment in power system.Its operation reliability has an important impact on the safe operation of power system.In the process of production,installation and ope... Oil immersed power transformer is the main electrical equipment in power system.Its operation reliability has an important impact on the safe operation of power system.In the process of production,installation and operation,its insulation structure may be damaged,resulting in partial discharge and even breakdown inside the transformer.In this paper,S9-M-100/10 oil immersed distribution transformer is taken as the research object,and the distribution laws of electromagnetic field and temperature field in transformer under normal operation,inter turn short circuit and inter layer short circuit are simulated and analyzed.The simulation results show that under normal conditions,the temperatures at the oil gap between the transformer core and the high and low voltage windings and the middle position of the high-voltage winding are high.When there are inter turn and inter layer short circuit faults,the electromagnetic loss of the fault part of the transformer increases,and the temperature rises suddenly.The influence of the two faults on the internal temperature field of the transformer is different,and the influence of the inter turn short circuit fault on the temperature nearby is obvious.The analysis results can provide reference for the thermal fault interpretation and fault classification of transformer. 展开更多
关键词 oil immersed power transformer finite element method electromagnetic field short circuit fault temperature field
在线阅读 下载PDF
A Discrete State Event Driven Simulation based Losses Analysis for Multi-terminal Megawatt Power Electronic Transformer 被引量:9
8
作者 Jialin Zheng Zhengming Zhao +3 位作者 Bochen Shi Zhujun Yu Jiahe Ju Zhiqiang Fan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期275-284,共10页
At present,power electronic transformers(PETs)have been widely used in power systems.With the increase of PET capacity to the megawatt level.the problem of increased losses need to be taken seriously.As an important i... At present,power electronic transformers(PETs)have been widely used in power systems.With the increase of PET capacity to the megawatt level.the problem of increased losses need to be taken seriously.As an important indicator of power electronic device designing,losses have always been the focus of attention.At present,the losses are generally measured through experiments,but it takes a lot of time and is difficult to quantitatively analyze the internal distribution of PET losses.To solve the above problems,this article first qualitatively analyzes the losses of power electronic devices and proposes a loss calculation method based on pure simulation.This method uses the Discrete State Event Driven(DSED)modeling method to solve the problem of slow simulation speed of large-capacity power electronic devices and uses a loss calculation method that considers the operating conditions of the device to improve the calculation accuracy.For the PET prototype in this article,a losses model of the PET is established.The comparison of experimental and simulation results verifies the feasibility of the losses model.Then the losses composition of PET was analyzed to provide reference opinions for actual operation.It can help pre-analyze the losses distribution of PET,thereby providing a potential method for improving system efficiency. 展开更多
关键词 Power electronic transformer(PET) losses analysis efficiency losses branch model discrete-state event-driven
在线阅读 下载PDF
Structured Microgrids (SμGs) and Flexible Electronic Large Power Transformers (FeLPTs) 被引量:5
9
作者 Don Tan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期255-263,共9页
Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs prov... Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs provide the integration of renewable energy and storage to balance the energy demand and supply as needed for a given system design.FeLPT’s flexibility for processing,control,and re-configurability offers the capability for flexible transmission for effective flow control and enable SμGs connectivity while still keeping multiscale system level control.Early adaptors for combined heat and power have demonstrated significant economic benefits while reducing environmental foot prints.They bring tremendous benefits to utility companies also.With storage and active control capabilities,a 300-percent increase in bulk transmission and distribution lines are possible without having to increase capacity.SμGs and FeLPTs will also enable the utility industry to be better prepared for the emerging large increase in base load demand from electric transportation and data centers.This is a win-win-win situation for the consumer,the utilities(grid operators),and the environment.SμGs and FeLPTs provide value in power substation,energy surety,reliability,resiliency,and security.It is also shown that the initial cost associated with SμG and FeLPTs deployment can be easily offset with reduced operating cost,which in turn reduces the total life-cycle cost by 33%to 67%. 展开更多
关键词 Terms-Structured microgrids flexible electronic large power transformers energy systems renewable integration grid modernization active control life-cycle cost
在线阅读 下载PDF
Power Transformer Fault Diagnosis Using Random Forest and Optimized Kernel Extreme Learning Machine 被引量:2
10
作者 Tusongjiang Kari Zhiyang He +3 位作者 Aisikaer Rouzi Ziwei Zhang Xiaojing Ma Lin Du 《Intelligent Automation & Soft Computing》 SCIE 2023年第7期691-705,共15页
Power transformer is one of the most crucial devices in power grid.It is significant to determine incipient faults of power transformers fast and accurately.Input features play critical roles in fault diagnosis accura... Power transformer is one of the most crucial devices in power grid.It is significant to determine incipient faults of power transformers fast and accurately.Input features play critical roles in fault diagnosis accuracy.In order to further improve the fault diagnosis performance of power trans-formers,a random forest feature selection method coupled with optimized kernel extreme learning machine is presented in this study.Firstly,the random forest feature selection approach is adopted to rank 42 related input features derived from gas concentration,gas ratio and energy-weighted dissolved gas analysis.Afterwards,a kernel extreme learning machine tuned by the Aquila optimization algorithm is implemented to adjust crucial parameters and select the optimal feature subsets.The diagnosis accuracy is used to assess the fault diagnosis capability of concerned feature subsets.Finally,the optimal feature subsets are applied to establish fault diagnosis model.According to the experimental results based on two public datasets and comparison with 5 conventional approaches,it can be seen that the average accuracy of the pro-posed method is up to 94.5%,which is superior to that of other conventional approaches.Fault diagnosis performances verify that the optimum feature subset obtained by the presented method can dramatically improve power transformers fault diagnosis accuracy. 展开更多
关键词 Power transformer fault diagnosis kernel extreme learning machine aquila optimization random forest
在线阅读 下载PDF
Research on power electronic transformer applied in AC/DC hybrid distribution networks 被引量:15
11
作者 Yiqun Miao Jieying Song +6 位作者 Haijun Liu Zhengang Lu Shufan Chen Chun Ding Tianzhi Cao Linhai Cai Yuzhong Gong 《Global Energy Interconnection》 2018年第3期396-403,共8页
The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/D... The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation. 展开更多
关键词 AC/DC hybrid distribution network Power electronic transformer(PET) Clamping double sub-module(CDSM) Energy router
在线阅读 下载PDF
Fault Diagnosis of Power Transformer Based on Improved ACGAN Under Imbalanced Data 被引量:1
12
作者 Tusongjiang.Kari Lin Du +3 位作者 Aisikaer.Rouzi Xiaojing Ma Zhichao Liu Bo Li 《Computers, Materials & Continua》 SCIE EI 2023年第5期4573-4592,共20页
The imbalance of dissolved gas analysis(DGA)data will lead to over-fitting,weak generalization and poor recognition performance for fault diagnosis models based on deep learning.To handle this problem,a novel transfor... The imbalance of dissolved gas analysis(DGA)data will lead to over-fitting,weak generalization and poor recognition performance for fault diagnosis models based on deep learning.To handle this problem,a novel transformer fault diagnosis method based on improved auxiliary classifier generative adversarial network(ACGAN)under imbalanced data is proposed in this paper,which meets both the requirements of balancing DGA data and supplying accurate diagnosis results.The generator combines one-dimensional convolutional neural networks(1D-CNN)and long short-term memories(LSTM),which can deeply extract the features from DGA samples and be greatly beneficial to ACGAN’s data balancing and fault diagnosis.The discriminator adopts multilayer perceptron networks(MLP),which prevents the discriminator from losing important features of DGA data when the network is too complex and the number of layers is too large.The experimental results suggest that the presented approach can effectively improve the adverse effects of DGA data imbalance on the deep learning models,enhance fault diagnosis performance and supply desirable diagnosis accuracy up to 99.46%.Furthermore,the comparison results indicate the fault diagnosis performance of the proposed approach is superior to that of other conventional methods.Therefore,the method presented in this study has excellent and reliable fault diagnosis performance for various unbalanced datasets.In addition,the proposed approach can also solve the problems of insufficient and imbalanced fault data in other practical application fields. 展开更多
关键词 Power transformer dissolved gas analysis imbalanced data auxiliary classifier generative adversarial network
在线阅读 下载PDF
Insulation System of Power Transformers Behavior Comparison of Mineral Oils and Natural Ester Dielectric Fluids 被引量:6
13
作者 R. Polansky P. Prosr V Mentlik J. Pihera P. Trnka 《Journal of Energy and Power Engineering》 2010年第12期51-56,共6页
Paper deals with a comparison of selected properties of several vegetable oil representatives along their accelerated thermal ageing at the temperature of 90 ℃. These properties are compared to two widely used and co... Paper deals with a comparison of selected properties of several vegetable oil representatives along their accelerated thermal ageing at the temperature of 90 ℃. These properties are compared to two widely used and commercially available mineral transformer oils. A combined insulating system (an oil-paper system) was created with the usage of mentioned oils for measurement purposes. Dissipation factor, capacity and volume resistance are characteristics measured along a thermal ageing of the oil-paper systems. Infrared spectroscopy was used as an additional method. After 1,000 hours of ageing, the dissipation factor of all systems based on vegetable oils did not exceed the value of 0.015. The volume resistance of systems containing mineral oils was approx, twice as high as the volume resistance of those with vegetable oils. The capacity on the other hand was slightly lower in the case of mineral oils application. An experiment also showed that the paper combined with the vegetable oil dries more quickly than in combination with the mineral oil. Infrared spectroscopy has not shown any expressive changes in the chemical structure of aU tested oils yet (up to 1,000 hours of ageing). 展开更多
关键词 Power transformer ECOSYSTEM biodegradable oils electrical properties.
在线阅读 下载PDF
Detection of Partial Discharge in Power Transformers Using Rogowski Coil and Multiresolution Analysis 被引量:1
14
作者 G.F.C. Veloso L.E. Borges da Silva +4 位作者 I. Noronha G. Lambert Torres J. Haddad R.R. Pereira Se UnAhn 《Journal of Energy and Power Engineering》 2010年第2期39-45,共7页
Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and e... Partial discharge detection in power transformers is discussed using a new approach that exploit the broad band of the Rogowski coils and the potential of two signal processing tools: discrete wavelet transform and empirical mode decomposition. Detecting and analyzing incipient activities of partial discharge can provide useful information to diagnostics and prognostics about transformer insulation. So, partial discharge signals embedded in the electric current at ground conductor are measured using the Rogowski coil. These signals are submitted to noise suppression and the partial discharges waveforms are extracted through different ways: using discrete wavelet transform and using empirical mode decomposition. The comparison of these two methods show that the extraction with discrete wavelet transform results in a faster and simpler algorithm than the empirical mode decomposition. But this one produces more precise waveforms due its adaptive characteristic. 展开更多
关键词 Discrete wavelet transform empirical mode decomposition partial discharge power transformer Rogowski coil.
在线阅读 下载PDF
State of the Art and Future Trends of Unconventional PD-Measurement at Power Transformers 被引量:1
15
作者 Jurgen Fabian Martin Neuwersch +2 位作者 Christof Sumereder Michael Muhr Robert Schwarz 《Journal of Energy and Power Engineering》 2014年第6期1093-1098,共6页
This paper discusses the current state of the art of diagnostics at power transformers. A special focus is set on the UHF-PD-measurement (ultra-high-frequency partial discharge measurement) because at power transfor... This paper discusses the current state of the art of diagnostics at power transformers. A special focus is set on the UHF-PD-measurement (ultra-high-frequency partial discharge measurement) because at power transformers, this diagnostic method has become more important in recent years. The current state, basics and principles of operations, proceedings as well as advantages of PD-measurement methods are covered. Furthermore problems and proposed solutions are discussed. Bushings and tap changers are not discussed in detail. In many cases, one single diagnostic method does not have the ability to sufficiently evaluate a power transformer. Therefore, a variety of diagnostic methods came up over times, which are commonly used by now. To expand the evaluation opportunities of power transformers, science strives to develop new diagnostic methods as well as to improve the existing ones. Furthermore, environmentally friendly and hardly inflammable ester liquids are examined for the use at power transformers and PD-measurement at HVDC (high voltage direct current) converter transformers as well. Potential diagnostic options and respectively current developments and findings in the field of oil-paper-insulation systems are outlined conclusively. 展开更多
关键词 Power transformer unconventional PD-measurement UHF-PD-measurement environmentally friendly alternativeinsulating liquids HVDC converter transformer.
在线阅读 下载PDF
Power Transformer Fault Diagnosis Using Fuzzy Reasoning Spiking Neural P Systems 被引量:1
16
作者 Yousif Yahya Ai Qian Adel Yahya 《Journal of Intelligent Learning Systems and Applications》 2016年第4期77-91,共15页
This paper presents an intelligent technique to fault diagnosis of power transformers dissolved and free gas analysis (DGA). Fuzzy Reasoning Spiking neural P systems (FRSN P systems) as a membrane computing with distr... This paper presents an intelligent technique to fault diagnosis of power transformers dissolved and free gas analysis (DGA). Fuzzy Reasoning Spiking neural P systems (FRSN P systems) as a membrane computing with distributed parallel computing model is powerful and suitable graphical approach model in fuzzy diagnosis knowledge. In a sense this feature is required for establishing the power transformers faults identifications and capturing knowledge implicitly during the learning stage, using linguistic variables, membership functions with “low”, “medium”, and “high” descriptions for each gas signature, and inference rule base. Membership functions are used to translate judgments into numerical expression by fuzzy numbers. The performance method is analyzed in terms for four gas ratio (IEC 60599) signature as input data of FRSN P systems. Test case results evaluate that the proposals method for power transformer fault diagnosis can significantly improve the diagnosis accuracy power transformer. 展开更多
关键词 Dissolved Gas Analysis Fault Diagnosis Fuzzy Reasoning Power transformer Faults Spiking Neural P System
在线阅读 下载PDF
Dual-Timescale Control for Power Electronic Zigzag Transformer 被引量:1
17
作者 Chunpeng Zhang Zhengming Zhao 《CES Transactions on Electrical Machines and Systems》 2017年第3期315-321,共7页
Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response... Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response and high-accuracy voltage source converters.This paper models its primary circuit and addresses its basic operation mechanism.Then a dual-timescale control scheme is investigated to realize the coordinated regulation of both types of converter.A simulation case is established in PSCAD containing interconnected mid-voltage distribution networks.Simulations with poor-and well-matched control timescales are both carried out.And accordingly,the power flow controllability under these conditions is compared.When the shorter control timescale is no more than tenth of the longer one,the power electronic zigzag transformer will operate with satisfying performances. 展开更多
关键词 Power electronic transformer thyristor converter voltage source converter dual-timescale control flexible interconnection
在线阅读 下载PDF
Price prediction of power transformer materials based on CEEMD and GRU
18
作者 Yan Huang Yufeng Hu +2 位作者 Liangzheng Wu Shangyong Wen Zhengdong Wan 《Global Energy Interconnection》 EI CSCD 2024年第2期217-227,共11页
The rapid growth of the Chinese economy has fueled the expansion of power grids.Power transformers are key equipment in power grid projects,and their price changes have a significant impact on cost control.However,the... The rapid growth of the Chinese economy has fueled the expansion of power grids.Power transformers are key equipment in power grid projects,and their price changes have a significant impact on cost control.However,the prices of power transformer materials manifest as nonsmooth and nonlinear sequences.Hence,estimating the acquisition costs of power grid projects is difficult,hindering the normal operation of power engineering construction.To more accurately predict the price of power transformer materials,this study proposes a method based on complementary ensemble empirical mode decomposition(CEEMD)and gated recurrent unit(GRU)network.First,the CEEMD decomposed the price series into multiple intrinsic mode functions(IMFs).Multiple IMFs were clustered to obtain several aggregated sequences based on the sample entropy of each IMF.Then,an empirical wavelet transform(EWT)was applied to the aggregation sequence with a large sample entropy,and the multiple subsequences obtained from the decomposition were predicted by the GRU model.The GRU model was used to directly predict the aggregation sequences with a small sample entropy.In this study,we used authentic historical pricing data for power transformer materials to validate the proposed approach.The empirical findings demonstrated the efficacy of our method across both datasets,with mean absolute percentage errors(MAPEs)of less than 1%and 3%.This approach holds a significant reference value for future research in the field of power transformer material price prediction. 展开更多
关键词 Power transformer material Price prediction Complementary ensemble empirical mode decomposition Gated recurrent unit Empirical wavelet transform
在线阅读 下载PDF
Breakdown Voltage Prediction by Utilizing the Behavior of Natural Ester for Transformer Applications
19
作者 P.Samuel Pakianathan R.V.Maheswari 《Intelligent Automation & Soft Computing》 SCIE 2023年第3期2717-2736,共20页
This research investigates the dielectric performance of Natural Ester(NE)using the Partial Differential Equation(PDE)tool and analyzes dielectric performance using fuzzy logic.NE nowadays is found to replace Mineral ... This research investigates the dielectric performance of Natural Ester(NE)using the Partial Differential Equation(PDE)tool and analyzes dielectric performance using fuzzy logic.NE nowadays is found to replace Mineral Oil(MO)due to its extensive dielectric properties.Here,the heat-tolerant Natural Esters Olive oil(NE1),Sunflower oil(NE2),and Ricebran oil(NE3)are subjected to High Voltage AC(HVAC)under different electrodes configurations.The break-down voltage and leakage current of NE1,NE2,and NE3 under Point-Point(P-P),Sphere-Sphere(S-S),Plane-Plane(PL-PL),and Rod-Rod(R-R)are measured,and survival probability is presented.The electricfield distribution is analyzed using the Partial Differential Equation(PDE)tool.NE shows better HVAC with stand capacity under all the electrodes configuration,especially in the S-S shape geometry.The exponential function is developed for the oils under different elec-trode geometry;NE shows a higher survival probability.Likewise,the most influ-ential dielectric properties such as breakdown voltage,kinematic viscosity,and water content are used to develop a Mamdani-based control system model that combines two variables to produce the surface model.The surface model indi-cates that the NE subjected for investigation is less susceptible to moisture effect and higher kinematic viscosity.Based on the surface models of PDE and fuzzy,it is concluded that NE possesses a high survival rate since its breakdown voltage does not react to changes in water content.Hence the application of NE in the transformer application is highly safe and possesses extended life. 展开更多
关键词 Power transformer fuzzy logic prediction partial differential equation natural ester exponential function
在线阅读 下载PDF
Unbalanced Load Simulation of Electronic Power Transformer in Distribution System
20
作者 Wang Dan Mao Chengxiong +3 位作者 Lu Jiming Fan Shu Cao Jiewei Wang Ben(Translated) 《Electricity》 2006年第1期38-43,共6页
A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads... A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads. The simple and appropriate control scheme was developed through analyzing the system requirements of the primary side and the load requirements of the secondary side. In the input section, a dual-loop control in synchronous rotating d-q coordinates was introduced, and in the output section, a dual-loop control based on instantaneous output voltage was used. Load characteristics of EPT were investigated by using Matlab/Simulink software. Simulation results showed that, with the proposed control scheme, the EPT has good performances and the sinusoidal input current and constant output voltage can be realized under both balanced and unbalanced loads. 展开更多
关键词 electronic power transformer distribution system unbalanced load