In this paper,a novel power grid evolving model,which can well describe the evolving property of power grids,is presented. Based on the BA model,motivated by the fact that in real power grids,connectivity of node not ...In this paper,a novel power grid evolving model,which can well describe the evolving property of power grids,is presented. Based on the BA model,motivated by the fact that in real power grids,connectivity of node not only depends on its degree,but also is influenced by many uncertain factors,so we introduce the subconnection factor K for each node. Using the mean-field theory,we get the analytical expression of power-law degree distribution with the exponent γ∈ (3,∞ ). Finally,simulation results show that the new model can provide a satisfactory description for empirical characteristics of power network,and power network falls somewhere in between scale-free network and uncertain network.展开更多
The uniform mathematical model of distortion signals in power grid has been setup with the theory of Wiener-G Functional. Firstly,the Matlab simulation models were established. Secondly,the Wiener kernel of power load...The uniform mathematical model of distortion signals in power grid has been setup with the theory of Wiener-G Functional. Firstly,the Matlab simulation models were established. Secondly,the Wiener kernel of power load was found based on the Gaussian white noise as input. And then the uniform mathematical model of the power grid signal was established according to the homogeneous of the same order of Wiener functional series. Finally,taking three typical distortion sources which are semiconductor rectifier,electric locomotive and electric arc furnace in power grid as examples,we have validated the model through the Matlab simulation and analyzed the simulation errors. The results show that the uniform mathematical model of distortion signals in power grid can approximation the actual model by growing the items of the series under the condition of the enough storage space and computing speed.展开更多
For economical reasons, wind turbine systems must be located in favourable sites generating a higher pro- ductivity. These are often located in areas with weak electric grid infrastructures. The constraints related to...For economical reasons, wind turbine systems must be located in favourable sites generating a higher pro- ductivity. These are often located in areas with weak electric grid infrastructures. The constraints related to this type of grids limit the penetration levels of wind energy. These constraints are mainly related to power quality in the grid as well as the economical aspects of the project. In this study, we take into account the slow voltage variations and the flicker phenomenon. The models used are based on the development of a set of relations derived from engineering knowledge related to both technical and economical points of view. The maximal penetration level of a fixed speed wind turbine system is determined for a given grid. The power control has been investigated to improve wind turbine system integration. Obtained results show the necessity to adapt technological choices to the requirements of weaker grids. Penetration levels and wind turbine cost may be greatly improved using variable speed systems.展开更多
This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(...This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(ASEAN)Power Grid.This study focuses on modeling and evaluating the dynamic performance of the interconnected system,considering the high penetration of renewable sources.Power flow,small signal stability,and transient stability analyses were conducted to assess the ability of the proposed linked power system models to withstand small and large disturbances,utilizing the Power Systems Analysis Toolbox(PSAT)software in MATLAB.All components used in the model are documented in the PSAT library.Currently,there is a lack of publicly available studies regarding the implementation of this specific system.Additionally,the study investigates the behavior of a system with a high penetration of renewable energy sources.Based on the findings,this study concludes that a system is generally stable when interconnection is realized,given its appropriate location and dynamic component parameters.Furthermore,the critical eigenvalues of the system also exhibited improvement as the renewable energy sources were augmented.展开更多
In this paper power electronics used in PV power generation systems have been reviewed and modelled. PV systems need converters for maximum power point tracking, power conditioning, voltage step-up/down as necessary, ...In this paper power electronics used in PV power generation systems have been reviewed and modelled. PV systems need converters for maximum power point tracking, power conditioning, voltage step-up/down as necessary, and for storage charge-controlling. Inverters are needed for AC loads and for utility grid interfacing. The four basic DC-DC converters commonly used with PV systems have been reviewed and modelled. Different DC-AC inverter types and operational architectures have also been reviewed with the two-stage DC-AC inverter, with the point of common coupling (PCC) at the inverter input, suggested as the most cost-effective and efficient architecture for PV-based communal grids. This is because only one inverter is used for the entire system as opposed to an inverter for every module string, resulting in higher efficiencies, low cost, and low harmonic distortions when compared to systems with PCC at AC terminal. The aim of power conversion/inversion is to extract maximum power possible from the PV system and where necessary, to invert it at close to 100% as possible. Highlight: 1) DC-DC converters are necessary for power conditioning in PV systems;2) DC-AC inverters are necessary for AC loads and for utility grid interfacing;3) DC-AC inverters are also used to control the PV systems when grid connected;4) Best inverter configuration cost-effectively and efficiently allows easy system modifications.展开更多
This paper discusses a distributed decision procedure for determining the electricity price for a real-time electricity market in an energy management system. The price decision algorithm proposed in this paper derive...This paper discusses a distributed decision procedure for determining the electricity price for a real-time electricity market in an energy management system. The price decision algorithm proposed in this paper derives the optimal electricity price while considering the constraints of a linearized AC power grid model. The algorithm is based on the power demand-supply balance and voltage phase differences in a power grid. In order to determine the optimal price that maximizes the social welfare distributively and to improve the convergence speed of the algorithm, the proposed algorithm updates the price through the alternating decision making of market participants. In this paper, we show the convergence of the price derived from our proposed algorithm. Furthermore, numerical simulation results show that the proposed dynamic pricing methodology is effective and that there is an improvement in the convergence speed, as compared with the conventional method.展开更多
The construction of intercontinental power grid interconnection projects is key to realizing the vision of Global Energy Interconnection,which is to solve global energy problems in a clean and sustainable manner.These...The construction of intercontinental power grid interconnection projects is key to realizing the vision of Global Energy Interconnection,which is to solve global energy problems in a clean and sustainable manner.These projects may be influenced by a few factors that are neither technological nor economic,such as political,social,and international factors.This paper thus presents a multi-level model for recognizing which factor from a compiled list of 14 would impact a particular intercontinental interconnection project and for assessing the degree of the factor’s influence.In the first part of the model,the Analytic Hierarchy Process(AHP)method is used to recognize the project’s most significant impact factors.Using the recognition results,the second part of the model can assess the degree of the factor’s influence on the project based on ratings provided by experts.A comprehensive evaluation can thus be provided.As a case study,the proposed Saudi Arabia-Ethiopia power grid interconnection project connecting Asia and Africa was analyzed.Derived from a combination of multiple opinions from experts,evaluations from the model will be of direct benefit to decision-makers,investors,project implementers,and engineers,providing them with a deeper insight into the project.展开更多
电网系统运行大安全管理数据规模较大,传统方法难以准确且快速地挖掘出异常数据。因此,文章提出了基于大语言模型(Large Language Model, LLM)的电网系统运行大安全管理异常数据挖掘。该方法在清洗并脱敏处理原始电网系统运行大安全管...电网系统运行大安全管理数据规模较大,传统方法难以准确且快速地挖掘出异常数据。因此,文章提出了基于大语言模型(Large Language Model, LLM)的电网系统运行大安全管理异常数据挖掘。该方法在清洗并脱敏处理原始电网系统运行大安全管理数据后,形成结构化的电网系统运行大安全管理数据集。通过构建LLM,该方法将结构化数据集输入模型,经训练后输出异常数据挖掘结果。实验分析表明,该方法数据挖掘结果的相对平方根误差仅为0.47%,交叉熵损失收敛值低至2.2146,显著优于传统聚类与小波方法,可为电网安全运行提供高效、可靠的异常监测支持。展开更多
Detailed procedures for the modeling of synthesis load models (SLM) of actual power network are presented, then the classification indices based on 1oad characteristics and the principle of load classification are exp...Detailed procedures for the modeling of synthesis load models (SLM) of actual power network are presented, then the classification indices based on 1oad characteristics and the principle of load classification are expounded. Based on the results of general investigation of 220 kV and 330kV substations in China’s power grid, the load characteristics are classified, and detailed load characteristic investigation of selected different kinds of typical substations are carried out. By use of statistical synthesis, the SLM for typical substations, in which the distribution networks are taken into account, are built;and the modeling results are disseminated and applied to whole Chinese power grid. Besides, the load model parameters are evaluated and verified via post-disturbance simulation method. The effectiveness of the built SLM is validated by the fitting of some disturbance incidents.展开更多
基金supported by the National Key Technology Research and Development Program of the Ministry of Science and Technology of China(Grant No.2008BAA13B01)
文摘In this paper,a novel power grid evolving model,which can well describe the evolving property of power grids,is presented. Based on the BA model,motivated by the fact that in real power grids,connectivity of node not only depends on its degree,but also is influenced by many uncertain factors,so we introduce the subconnection factor K for each node. Using the mean-field theory,we get the analytical expression of power-law degree distribution with the exponent γ∈ (3,∞ ). Finally,simulation results show that the new model can provide a satisfactory description for empirical characteristics of power network,and power network falls somewhere in between scale-free network and uncertain network.
基金Sponsored by the National Natural Science Foundation of China(Grant No.51277043)
文摘The uniform mathematical model of distortion signals in power grid has been setup with the theory of Wiener-G Functional. Firstly,the Matlab simulation models were established. Secondly,the Wiener kernel of power load was found based on the Gaussian white noise as input. And then the uniform mathematical model of the power grid signal was established according to the homogeneous of the same order of Wiener functional series. Finally,taking three typical distortion sources which are semiconductor rectifier,electric locomotive and electric arc furnace in power grid as examples,we have validated the model through the Matlab simulation and analyzed the simulation errors. The results show that the uniform mathematical model of distortion signals in power grid can approximation the actual model by growing the items of the series under the condition of the enough storage space and computing speed.
文摘For economical reasons, wind turbine systems must be located in favourable sites generating a higher pro- ductivity. These are often located in areas with weak electric grid infrastructures. The constraints related to this type of grids limit the penetration levels of wind energy. These constraints are mainly related to power quality in the grid as well as the economical aspects of the project. In this study, we take into account the slow voltage variations and the flicker phenomenon. The models used are based on the development of a set of relations derived from engineering knowledge related to both technical and economical points of view. The maximal penetration level of a fixed speed wind turbine system is determined for a given grid. The power control has been investigated to improve wind turbine system integration. Obtained results show the necessity to adapt technological choices to the requirements of weaker grids. Penetration levels and wind turbine cost may be greatly improved using variable speed systems.
文摘This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(ASEAN)Power Grid.This study focuses on modeling and evaluating the dynamic performance of the interconnected system,considering the high penetration of renewable sources.Power flow,small signal stability,and transient stability analyses were conducted to assess the ability of the proposed linked power system models to withstand small and large disturbances,utilizing the Power Systems Analysis Toolbox(PSAT)software in MATLAB.All components used in the model are documented in the PSAT library.Currently,there is a lack of publicly available studies regarding the implementation of this specific system.Additionally,the study investigates the behavior of a system with a high penetration of renewable energy sources.Based on the findings,this study concludes that a system is generally stable when interconnection is realized,given its appropriate location and dynamic component parameters.Furthermore,the critical eigenvalues of the system also exhibited improvement as the renewable energy sources were augmented.
文摘In this paper power electronics used in PV power generation systems have been reviewed and modelled. PV systems need converters for maximum power point tracking, power conditioning, voltage step-up/down as necessary, and for storage charge-controlling. Inverters are needed for AC loads and for utility grid interfacing. The four basic DC-DC converters commonly used with PV systems have been reviewed and modelled. Different DC-AC inverter types and operational architectures have also been reviewed with the two-stage DC-AC inverter, with the point of common coupling (PCC) at the inverter input, suggested as the most cost-effective and efficient architecture for PV-based communal grids. This is because only one inverter is used for the entire system as opposed to an inverter for every module string, resulting in higher efficiencies, low cost, and low harmonic distortions when compared to systems with PCC at AC terminal. The aim of power conversion/inversion is to extract maximum power possible from the PV system and where necessary, to invert it at close to 100% as possible. Highlight: 1) DC-DC converters are necessary for power conditioning in PV systems;2) DC-AC inverters are necessary for AC loads and for utility grid interfacing;3) DC-AC inverters are also used to control the PV systems when grid connected;4) Best inverter configuration cost-effectively and efficiently allows easy system modifications.
基金supported by the Core Research for Evolutional Science and Technology,Japan Science and Technology Agency(JST-CREST)
文摘This paper discusses a distributed decision procedure for determining the electricity price for a real-time electricity market in an energy management system. The price decision algorithm proposed in this paper derives the optimal electricity price while considering the constraints of a linearized AC power grid model. The algorithm is based on the power demand-supply balance and voltage phase differences in a power grid. In order to determine the optimal price that maximizes the social welfare distributively and to improve the convergence speed of the algorithm, the proposed algorithm updates the price through the alternating decision making of market participants. In this paper, we show the convergence of the price derived from our proposed algorithm. Furthermore, numerical simulation results show that the proposed dynamic pricing methodology is effective and that there is an improvement in the convergence speed, as compared with the conventional method.
基金supported by the State Grid Science and Technology Project“Research on Method and Evaluation Principle for the Cross-Continent Power Transmission Planning Scheme”(SGTYHT/16-JS-198)。
文摘The construction of intercontinental power grid interconnection projects is key to realizing the vision of Global Energy Interconnection,which is to solve global energy problems in a clean and sustainable manner.These projects may be influenced by a few factors that are neither technological nor economic,such as political,social,and international factors.This paper thus presents a multi-level model for recognizing which factor from a compiled list of 14 would impact a particular intercontinental interconnection project and for assessing the degree of the factor’s influence.In the first part of the model,the Analytic Hierarchy Process(AHP)method is used to recognize the project’s most significant impact factors.Using the recognition results,the second part of the model can assess the degree of the factor’s influence on the project based on ratings provided by experts.A comprehensive evaluation can thus be provided.As a case study,the proposed Saudi Arabia-Ethiopia power grid interconnection project connecting Asia and Africa was analyzed.Derived from a combination of multiple opinions from experts,evaluations from the model will be of direct benefit to decision-makers,investors,project implementers,and engineers,providing them with a deeper insight into the project.
文摘电网系统运行大安全管理数据规模较大,传统方法难以准确且快速地挖掘出异常数据。因此,文章提出了基于大语言模型(Large Language Model, LLM)的电网系统运行大安全管理异常数据挖掘。该方法在清洗并脱敏处理原始电网系统运行大安全管理数据后,形成结构化的电网系统运行大安全管理数据集。通过构建LLM,该方法将结构化数据集输入模型,经训练后输出异常数据挖掘结果。实验分析表明,该方法数据挖掘结果的相对平方根误差仅为0.47%,交叉熵损失收敛值低至2.2146,显著优于传统聚类与小波方法,可为电网安全运行提供高效、可靠的异常监测支持。
文摘Detailed procedures for the modeling of synthesis load models (SLM) of actual power network are presented, then the classification indices based on 1oad characteristics and the principle of load classification are expounded. Based on the results of general investigation of 220 kV and 330kV substations in China’s power grid, the load characteristics are classified, and detailed load characteristic investigation of selected different kinds of typical substations are carried out. By use of statistical synthesis, the SLM for typical substations, in which the distribution networks are taken into account, are built;and the modeling results are disseminated and applied to whole Chinese power grid. Besides, the load model parameters are evaluated and verified via post-disturbance simulation method. The effectiveness of the built SLM is validated by the fitting of some disturbance incidents.