Pump valve pipeline vibration brings serious safety hazards to the operation of the equipment,for the pump valve system in the process of variable flow,variable speed,variable openings lead to excessive pipeline vibra...Pump valve pipeline vibration brings serious safety hazards to the operation of the equipment,for the pump valve system in the process of variable flow,variable speed,variable openings lead to excessive pipeline vibration.An active damping device(ADD)is used to the vibration of the pump valve pipeline system to apply the control force,to achieve the active control of the pipeline vibration.A pump-valve pipeline vibration test bench was built to compare the control effect of active damping device on pipeline vibration under different pump valve working conditions,and the results show that applying ADD control could effectively suppress the vibration of the pump valve pipeline and enhance the stability of the equipment during operation.At different pump operating rotation frequencies,the vibration amplitude of the pump valve pipeline in working frequency and its multiple frequencies are also effectively suppressed,with the maximum amplitude reduction of more than 60%.For the valve vibration caused by different operating openings,the vibration of the highest reduction of 68%,and the centrifugal pump drive shaft vi-bration reduced by up to 73%,which provides a new idea for vibration control of pump valve pipeline system.展开更多
Water hammer following the tripping of pumps can lead to overpressure and negative pressure. Reduction in overpressure and negative pressure may be necessary to avoid failure, to improve the efficiency of operation an...Water hammer following the tripping of pumps can lead to overpressure and negative pressure. Reduction in overpressure and negative pressure may be necessary to avoid failure, to improve the efficiency of operation and to avoid fatigue of system components. The field tests on the water hammer have been conducted on the pump rising pipeline system with an air chamber. The hydraulic transient was simulated using the method of characteristics. Minimizing the least squares problem representing the difference between the measured and predicted transient response in the system performs the calibration of the simulation program. Among the input variables used in the water hammer analysis, the polytropic exponent, the discharge coefficient and the wave speed were calibrated. The computer program developed in this study will be useful in designing the optimum parameters of an air chamber for the real pump pipeline system. The correct selection of air chamber size and the effect of the inner diameter of the orifice to minimize water hammer have been investigated by both field measurements and numerical modeling.展开更多
基金The Fundamental Research Funds for the Central Universities(JD2423)。
文摘Pump valve pipeline vibration brings serious safety hazards to the operation of the equipment,for the pump valve system in the process of variable flow,variable speed,variable openings lead to excessive pipeline vibration.An active damping device(ADD)is used to the vibration of the pump valve pipeline system to apply the control force,to achieve the active control of the pipeline vibration.A pump-valve pipeline vibration test bench was built to compare the control effect of active damping device on pipeline vibration under different pump valve working conditions,and the results show that applying ADD control could effectively suppress the vibration of the pump valve pipeline and enhance the stability of the equipment during operation.At different pump operating rotation frequencies,the vibration amplitude of the pump valve pipeline in working frequency and its multiple frequencies are also effectively suppressed,with the maximum amplitude reduction of more than 60%.For the valve vibration caused by different operating openings,the vibration of the highest reduction of 68%,and the centrifugal pump drive shaft vi-bration reduced by up to 73%,which provides a new idea for vibration control of pump valve pipeline system.
文摘Water hammer following the tripping of pumps can lead to overpressure and negative pressure. Reduction in overpressure and negative pressure may be necessary to avoid failure, to improve the efficiency of operation and to avoid fatigue of system components. The field tests on the water hammer have been conducted on the pump rising pipeline system with an air chamber. The hydraulic transient was simulated using the method of characteristics. Minimizing the least squares problem representing the difference between the measured and predicted transient response in the system performs the calibration of the simulation program. Among the input variables used in the water hammer analysis, the polytropic exponent, the discharge coefficient and the wave speed were calibrated. The computer program developed in this study will be useful in designing the optimum parameters of an air chamber for the real pump pipeline system. The correct selection of air chamber size and the effect of the inner diameter of the orifice to minimize water hammer have been investigated by both field measurements and numerical modeling.