Nitrogen and phosphorus removal in pilot-scale anaerobic-anoxic oxidation ditch system 被引量:35
1
作者 PENG Yongzhen HOU Hongxun +2 位作者 WANG Shuying CUI Youwei Zhiguo Yuan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第4期398-403,共6页
To achieve high efficiency of nitrogen and phosphorus removal and to investigate the rule of simultaneous nitrification and denitrification phosphorus removal (SNDPR), a whole course of SNDPR damage and recovery was... To achieve high efficiency of nitrogen and phosphorus removal and to investigate the rule of simultaneous nitrification and denitrification phosphorus removal (SNDPR), a whole course of SNDPR damage and recovery was studied in a pilot-scale, anaerobicanoxic oxidation ditch (OD), where the volumes of anaerobic zone, anoxic zone, and ditches zone of the OD system were 7, 21, and 280 L, respectively. The reactor was fed with municipal wastewater with a flow rate of 336 L/d. The concept of simultaneous nitrification and denitrification (SND) rate (rSND) was put forward to quantify SND. The results indicate that: (1) high nitrogen and phosphorus removal efficiencies were achieved during the stable SND phase, total nitrogen (TN) and total phosphate (TP) removal rates were 80% and 85%, respectively; (2) when the system was aerated excessively, the stability of SND was damaged, and rSND dropped from 80% to 20% or less; (3) the natural logarithm of the ratio of NOx to NH4^+ in the effluent had a linear correlation to oxidation-reduction potential (ORP); (4) when NO3^- was less than 6 mg/L, high phosphorus removal efficiency could be achieved; (5) denitrifying phosphorus removal (DNPR) could take place in the anaerobic-anoxic OD system. The major innovation was that the SND rate was devised and quantified. 展开更多
关键词 oxidation ditch biological nitrogen removal biological phosphorus removal simultaneous nitrification and denitrification (SND) pilot scale municipal wastewater
在线阅读 下载PDF
Pilot-scale Study on Electro-catalytic Oxidation of High-salt Wastewater from Coal Chemical Industry
2
作者 ZHAOHaixia 《外文科技期刊数据库(文摘版)自然科学》 2022年第6期059-062,共4页
Industrial wastewater from modern industrial production often contains excessive organic hazardous substances or excessive salts, acids and bases, etc. Traditional methods cannot play an effective role in the treatmen... Industrial wastewater from modern industrial production often contains excessive organic hazardous substances or excessive salts, acids and bases, etc. Traditional methods cannot play an effective role in the treatment of such wastewater. Moreover, since such wastewater is also not suitable for the growth of microorganisms, the way of wastewater treatment by microorganisms is also greatly limited. For this kind of industrial waste water, apart from the degradation of organic matters, the separation of inorganic salts and waste water is also required to meet the sewage discharge standard. Based on this, the article focuses on the coal chemical high salt wastewater electro-catalytic oxidation pilot study. 展开更多
关键词 coal chemical industry high-salt wastewater electro-catalytic oxidation pilot-scale study
原文传递
An innovative integrated oxidation ditch with vertical circle(IODVC) for wastewater treatment 被引量:20
3
作者 XIAShi-bin LIUJun-xin 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2004年第3期367-370,共4页
The oxidation ditch process is economic and efficient for wastewater treatment, but its application is limited in case where land is costly due to its large land area required. An innovative integrated oxidation ditch... The oxidation ditch process is economic and efficient for wastewater treatment, but its application is limited in case where land is costly due to its large land area required. An innovative integrated oxidation ditch with vertical circle(IODVC) system was developed to treat domestic and industrial wastewater aiming to save land area. The new system consists of a single channel divided into two ditches(the top one and the bottom one by a plate), a brush, and an innovative integral clarifier. Different from the horizontal circle of the conventional oxidation ditch, the flow of IODVC system recycles from the top zone to the bottom zone in the vertical circle as the brush is running, and then the IODVC saved land area required by about 50% compared with a conventional oxidation ditch with an intrachannel clarifier. The innovative integral clarifier is effective for separation of liquid and solids, and is preferably positioned at the opposite end of the brush in the ditch. It does not affect the hydrodynamic characteristics of the mixed liquor in the ditch, and the sludge can automatically return to the down ditch without any pump. In this study, experiments of domestic and dye wastewater treatment were carried out in bench scale and in full scale, respectively. Results clearly showed that the IODVC efficiently removed pollutants in the wastewaters, i.e., the average of COD removals for domestic and dye wastewater treatment were 95% and 90%, respectively, and that the IODVC process may provide a cost effective way for full scale dye wastewater treatment. 展开更多
关键词 integrated oxidation ditch vertical circle domestic wastewater dye wastewater treatment
在线阅读 下载PDF
Removal of airborne microorganisms emitted from a wastewater treatment oxidation ditch by adsorption on activated carbon 被引量:11
4
作者 Lin Li Min Gao Junxin Liu Xuesong Guo 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2011年第5期711-717,共7页
Bioaerosol emissions from wastewater and wastewater treatment processes are a significant subgroup of atmospheric aerosols. Most previous work has focused on the evaluation of their biological risks. In this study, ho... Bioaerosol emissions from wastewater and wastewater treatment processes are a significant subgroup of atmospheric aerosols. Most previous work has focused on the evaluation of their biological risks. In this study, however, the adsorption method was applied to reduce airborne microorganisms generated from a pilot scale wastewater treatment facility with oxidation ditch. Results showed adsorption on granule activated carbon (GAC) was an efficient method for the purification of airborne microorganisms. The GAC itself had a maximum adsorption capacity of 2217 CFU/g for airborne bacteria and 225 CFU/g for fungi with a flow rate of 1.50 m^3/hr. Over 85% of airborne bacteria and fungi emitted from the oxidation ditch were adsorbed within 80 hr of continuous operation mode. Most of them had a particle size of 0.65-4.7 μm. Those airborne microorganisms with small particle size were apt to be adsorbed. The SEM/EDAX, BET and Boehm's titration methods were applied to analyse the physicochemical characteristics of the GAC. Relationships between GAC surface characteristics and its adsorption performance demonstrated that porous structure, large surface area, and hydrophobicity rendered GAC an effective absorber of airborne microorganisms. Two regenerate methods, ultraviolet irradiation and high pressure vapor, were compared for the regeneration of used activated carbon. High pressure vapor was an effective technique as it totally destroyed the microorganisms adhered to the activated carbon. Microscopic observation was also carried out to investigate original and used adsorbents. 展开更多
关键词 activated carbon ADSORPTION airborne microorganisms oxidation ditch wastewater treatment facility
原文传递
Numerical simulation of a combined oxidation ditch flow using 3D k-ε turbulence model 被引量:8
5
作者 LUO Lin LI Wei-min +1 位作者 DENG Yong-sen WANG Tao 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第5期808-812,共5页
The standard three dimensional(3D) k-ε turbulence model was applied to simulate the flow field of a small scale combined oxidation ditch. The moving mesh approach was used to model the rotor of the ditch. Compariso... The standard three dimensional(3D) k-ε turbulence model was applied to simulate the flow field of a small scale combined oxidation ditch. The moving mesh approach was used to model the rotor of the ditch. Comparison of the computed and the measured data is acceptable. A vertical reverse flow zone in the ditch was found, and it played a very important role in the ditch flow behavior. The flow pattern in the ditch is discussed in detail, and approaches are suggested to improve the hydrodynamic performance in the ditch. 展开更多
关键词 oxidation ditch 3D simulation turbulence flow
在线阅读 下载PDF
Flow field and dissolved oxygen distributions in the outer channel of the Orbal oxidation ditch by monitor and CFD simulation 被引量:6
6
作者 Xuesong Guo Xin Zhou +1 位作者 Qiuwen Chen Junxin Liu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2013年第4期645-651,共7页
In the Orbal oxidation ditch, denitrification is primarily accomplished in the outer channel. However, the detailed characteristics of the flow field and dissolved oxygen (DO) distribution in the outer channel are n... In the Orbal oxidation ditch, denitrification is primarily accomplished in the outer channel. However, the detailed characteristics of the flow field and dissolved oxygen (DO) distribution in the outer channel are not well understood. Therefore, in this study, the flow velocity and DO concentration in the outer channel of an Orbal oxidation ditch system in a wastewater treatment plant in Beijing (China) were monitored under actual operation conditions. The flow field and DO concentration distributions were analyzed by computed fluid dynamic modeling. In situ monitoring and modeling both showed that the flow velocity was heterogeneous in the outer channel. As a result, the DO was also heterogeneously distributed in the outer channel, with concentration gradients occurring along the flow direction as well as in the cross-section. This heterogeneous DO distribution created many anoxic and aerobic zones, which may have facilitated simultaneous nitrificafion-denitrification in the channel. These findings may provide supporting information for rational optimization of the performance of the Orbal oxidation ditch. 展开更多
关键词 computed fluid dynamic dissolved oxygen distribution flow field Orbal oxidation ditch
原文传递
Enhanced biological nutrients removal using an integrated oxidation ditch with vertical circle from wastewater by adding an anaerobic column 被引量:4
7
作者 WANG Shu-mei LIU Jun-xin 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2005年第6期894-898,共5页
Compared to conventional oxidation ditches, an integrated oxidation ditch with vertical circle (IODVC) has the characters of concise configuration, simple operation and maintenance, land saving and automatical sludg... Compared to conventional oxidation ditches, an integrated oxidation ditch with vertical circle (IODVC) has the characters of concise configuration, simple operation and maintenance, land saving and automatical sludge returning. By the utilization of vertical circulation, an aerobic zone and an anoxic zone can be unaffectedly formed in the IODVC. Therefore, COD and nitrogen can be efficiently removed. However, the removal efficiency of phosphorus was low in the IODVC. In the experiment described, a laboratory scale system to add an anaerobic column to the IODVC has been tested to investigate the removal of phosphorus from wastewater. The experimental results showed that the removal efficiency of TP with the anaerobic column was increased to 54.0% from 22.3% without the anaerobic column. After the acetic sodium was added into the influent as carbon sources, the mean TP removal efficency of 77. 5 % was obtained. At the same time, the mean removal efficiencies of COD, TN and NH3-N were 92.2%, 81.6% and 98.1%, respectively, at 12 h of HRT and 21-25 d of SRT. The optimal operational conditions in this study were as follows: recycle rate = 1.5-2.0, COD/TN 〉 6, COD/TP 〉 40, COD loading rate = 0.26-0.32 kgCOD/(kgSS· d), TN loading rate = 0. 028-0. 034 kgTN/( kgSS·d) and TP loading rate = 0.003-0.005 kgTP/(kgSS· d), respectively. 展开更多
关键词 integrative oxidation ditch with vertical circle wastewater treatment biological nutrient removal
在线阅读 下载PDF
Addition of anaerobic tanks to an oxidation ditch system to enhance removal of phosphorus from wastewater 被引量:3
8
作者 LiuJX GroeJW 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2002年第2期245-249,共5页
The oxidation ditch has been used for many years all over the world as an economic and efficient wastewater treatment technology. It can remove COD, nitrogen and a part of phosphorus efficiently. In the experiment des... The oxidation ditch has been used for many years all over the world as an economic and efficient wastewater treatment technology. It can remove COD, nitrogen and a part of phosphorus efficiently. In the experiment described, a pilot scale Pasveer oxidation ditch system has been tested to investigate the removal of phosphorus from wastewater. The experimental results showed that influent total phosphorus(TP) was removed for 35%-50%. After this, two anaerobic tanks with total volume of 11 m 3 were added to the system to release phosphorus. As a result, the TP removal efficiency increased by about 20%. At an anaerobic HRT of about 6 hours, a TP removal efficiency of 71% was achieved. 展开更多
关键词 phosphorus removal oxidation ditch wastewater treatment
在线阅读 下载PDF
Variation of biological and hydrological parameters and nitrogen removal optimization of modified Carrousel oxidation ditch process 被引量:6
9
作者 张智 李柏林 +2 位作者 相欣奕 张驰 柴华 《Journal of Central South University》 SCIE EI CAS 2012年第3期842-849,共8页
To enhance the nitrogen removal,a systemic monitoring of the biological and hydrological parameters of Carrousel oxidation ditch in Chongqing Jingkou Wastewater Treatment Plant was carried out to study the feasibility... To enhance the nitrogen removal,a systemic monitoring of the biological and hydrological parameters of Carrousel oxidation ditch in Chongqing Jingkou Wastewater Treatment Plant was carried out to study the feasibility of simultaneous nitrification and denitrification(SND).The variation and distribution of parameters such as flow velocity,concentration of dissolved oxygen(DO) and mixed liquor suspended solids(MLSS) in oxidation ditch were monitored and analyzed,which were major control factors for SND.The results showed that,the dimensional distribution of flow velocity,DO and MLSS were affected significantly by the operation condition of the aeration wheels.With all the four aeration wheels being in operation,DO and flow velocity were higher and the mixing of MLSS was sufficient.With three aeration wheels being in operation,the flow velocity in most of the bottom areas was enough to meet the basic requirements of no deposition,and the anaerobic region and aerobic region could exist simultaneously in one oxidation ditch,which was helpful to the process of SND.According to spatial distribution characteristics of the flow velocity,DO and soluble components under optimized condition,different functional zones of biochemical reaction in the Carrousel oxidation ditch system were defined,which might contribute to the optimization control and SND of Carrousel oxidation ditch. 展开更多
关键词 Carrousel oxidation ditch flow velocity dissolved oxygen (DO) mixed liquor suspended solid (MLSS) simultaneous nitrification and denitrification (SND)
在线阅读 下载PDF
Effect of Return Sludge Pre-concentration on Biological Phosphorus Removal in a Novel Oxidation Ditch 被引量:3
10
作者 刘巍 杨殿海 +4 位作者 徐立 贾川 卢文建 BOSIRE Omosa Isaiah 沈昌明 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第4期747-753,共7页
A pilot-scale,pre-anoxic-anaerobic oxidation ditch was used in this study to treat municipal wastewater with limited carbon source.A novel return activated sludge(RAS) pre-concentration tank was adopted for improv-ing... A pilot-scale,pre-anoxic-anaerobic oxidation ditch was used in this study to treat municipal wastewater with limited carbon source.A novel return activated sludge(RAS) pre-concentration tank was adopted for improv-ing the phosphorus removal efficiency and the effects of RAS pre-concentration ratio were studied.Under the opti-mal operational condition,the suspended total phosphorus(STP) and the total phosphorus(TP) removal efficiencies were around 58.9% and 63.9% respectively and the effluent-P was lower than 0.8 mg·L-1.The reason is that with the optimal RAS pre-concentration ratio,nitrate is completely removed with endogenous carbon source and the secondary phosphorus release is strictly restrained in the pre-anoxic tank.Therefore,the anaerobic phosphorus release and the carbon source uptake by phosphorus accumulation organisms(PAOs) in the sludge,which are ex-tremely important to the phosphorus removal process,can be fully satisfied.Furthermore,the oxidation-reduction potential is proved to be suitable for controlling the RAS pre-concentration ratio due to influent fluctuation and varied conditions.The novel modified system is also beneficial for PAO accumulation. 展开更多
关键词 denitrifying phosphorus removal NITRATE oxidation ditch phosphorus return activated sludge pre-concentration secondary phosphorus release
在线阅读 下载PDF
Evaluation on the performance of triple oxidation ditch system treating municipal wastewater
11
作者 Zhou Lu, Qian Yi National Key Joint Laboratory on Environmental Simulation and Water Pollution Control, Department of Environmental Engineering,Tsinghua University, Beijing 100084, China 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1997年第3期4-11,共8页
The oxidation ditch system in Handan WWTP is the biggest triple oxidation ditch system (T O.D.) treating municipal wastewater in China with a service population of 350000. The system can perform three functions, aer... The oxidation ditch system in Handan WWTP is the biggest triple oxidation ditch system (T O.D.) treating municipal wastewater in China with a service population of 350000. The system can perform three functions, aerobic, anoxic and precipitation process in different ditch by alternating the operation mode, and the simultaneous removal of nitrogen and organic substances can be attained. Statistic analysis of data from past five year operation in the WWTP was presented, and investigations on COD, nitrogen, phosphorus removal in system were carried out in the field. The optimum number of aerated brush to meet satisfied nitrification and denitrification was determined on basis of field experiment. The effluent is reused as cooling water for a electricity power plant, and excess sludge is utilized as fertilizer. The concept of an ecological WWTP is put forward by the example of Handan WWTP. 展开更多
关键词 oxidation ditch NITRIFICATION denitrificaiton WASTEWATER ecological WWTP.
在线阅读 下载PDF
Numerical study on hydraulic performance of submerged propellers in oxidation ditch
12
作者 Wu Siyuan Zhou Daqing Zheng Yuan 《排灌机械工程学报》 EI 北大核心 2014年第12期1068-1073,1104,共7页
The submerged propeller is an efficient diving mix device,which is applicable for oxidation ditch treatment in industry,city and village wastewater-treatment plant. The impeller structure and reasonable rotating speed... The submerged propeller is an efficient diving mix device,which is applicable for oxidation ditch treatment in industry,city and village wastewater-treatment plant. The impeller structure and reasonable rotating speed are important factors that determine flow field distribution and energy conversion efficiency. So it is necessary to use modern design methods to develop new kinds of high efficiency submerged propellers,and research the flow field characteristics of submerged propellers. On the basis of the existing form drawing,three-dimensional model of submerged propellers and unstructured tetrahedral mesh were generated. Based on Navier- Stokes equations and standard k- ε turbulence model,the flow was simulated by using a simple algorithm. Through changing some design parameters of propellers,the corresponding numerical simulation results reveal that for the same impeller diameter and service area of submerged propellers,the power consumption could be reduced effectively by optimizing blade mounting angle,which can determine the best blade mounting angle and most suitable rotational speed under given conditions. The study can provide theoretical and project guidance for submerged propellers design. 展开更多
关键词 PROPELLERS hydrologic performance oxidation ditch BLADE MOUNTING angle ROTATIONAL speed numerical simulation
在线阅读 下载PDF
Cost-performance analysis of nutrient removal in a full-scale oxidation ditch process based on kinetic modeling
13
作者 Zheng Li Rong Qi +3 位作者 Bo Wang Zhe Zou Guohong Wei Min Yang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2013年第1期26-32,共7页
A full-scale oxidation ditch process for treating sewage was simulated with the ASM2d model and optimized for minimal cost with acceptable performance in terms of ammonium and phosphorus removal. A unified index was i... A full-scale oxidation ditch process for treating sewage was simulated with the ASM2d model and optimized for minimal cost with acceptable performance in terms of ammonium and phosphorus removal. A unified index was introduced by integrating operational costs (aeration energy and sludge production) with effluent violations for performance evaluation. Scenario analysis showed that, in comparison with the baseline (all of the 9 aerators activated), the strategy of activating 5 aerators could save aeration energy significantly with an ammonium violation below 10%. Sludge discharge scenario analysis showed that a sludge discharge flow of 250- 300 ma/day (solid retention time (SRT), 13-15 days) was appropriate for the enhancement of phosphorus removal without excessive sludge production. The proposed optimal control strategy was: activating 5 rotating disks operated with a mode of "111100100" ( "1" represents activation and "0" represents inactivation) for aeration and sludge discharge flow of 200 m3/day (SRT, 19 days). Compared with the baseline, this strategy could achieve ammonium violation below 10% and TP violation below 30% with substantial reduction of aeration energy cost (46%) and minimal increment of sludge production (〈 2%). This study provides a useful approach for the optimization of process operation and control. 展开更多
关键词 activated sludge model cost-performance analysis oxidation ditch nutrient removal
原文传递
Simulation of liquid-gas flow in full-scale Caroussel oxidation ditch with surface aeration
14
作者 李振亮 郭丽莎 +1 位作者 张代钧 许丹语 《Journal of Central South University》 SCIE EI CAS 2012年第6期1615-1621,共7页
A model for liquid-gas flow (MLGF), considering the flee movement of liquid surface, was built to simulate the wastewater velocity field and gas distribution in a full-scale Caroussel oxidation ditch with surface ae... A model for liquid-gas flow (MLGF), considering the flee movement of liquid surface, was built to simulate the wastewater velocity field and gas distribution in a full-scale Caroussel oxidation ditch with surface aeration. It was calibrated and validated by field measurement data, and the calibrated parameters and sections were selected based on both model analysis and numerical computation. The simulated velocities of MLGF were compared to that of a model for wastewater-sludge flow (MWSF). The results show that the free liquid surface considered in MLGF improves the simulated velocity results of upper layer and surface. Moreover, distribution of gas volume fraction (GVF) simulated by MLGF was compared to dissolved oxygen (DO) measured in the oxidation ditch. It is shown that DO distribution is affected by many factors besides GVF distribution. 展开更多
关键词 liquid-gas flow computational fluid dynamics technique oxidation ditch surface free movement gas volume fraction
在线阅读 下载PDF
Discussion on nitrogen and phosphorus removal process characteristics of improved oxidation ditch
15
作者 SHEN Lian-feng JIN Yue +1 位作者 ZHANG Jian-xin LI You 《Journal of Environmental Science and Engineering》 2008年第5期31-34,共4页
In order to enhance efficiency of the nitrogen and phosphorus removal of sewage treatment plant, Taking Wu Long kou sewage treatment plant project in Zhengzhou as an example, this article introduces the structure, the... In order to enhance efficiency of the nitrogen and phosphorus removal of sewage treatment plant, Taking Wu Long kou sewage treatment plant project in Zhengzhou as an example, this article introduces the structure, the working principle, the craft character, as well as the problems existed in the practical application of the improved oxidation ditch, and raises some corresponding processing countermeasures. Looked from the running situation of Wu Long kou sewage treatment plant, the improved oxidation ditch have certain advantages in city sewage treatment, such as high organic removing efficiency, good removing effect of nitrogen and phosphorus, low investing expenses and operating cost and so on. It is a craft that is worth promoting in urban sewage treatment. 展开更多
关键词 improved oxidation ditch urban sewage nitrogen and phosphorus removal
在线阅读 下载PDF
Flow characteristic and wastewater treatment performance of a pilot-scale airlift oxidation ditch 被引量:3
16
作者 Hongtao PANG Hanchang SHI Huiming SHI 《Frontiers of Environmental Science & Engineering》 SCIE EI CSCD 2009年第4期470-476,共7页
A pilot-scale airlift oxidation ditch using bubble diffuser and baffle as aerator was operated in a wastewater treatment plant(WWTP)to investigate its flow characteristic and wastewater treatment performance.Compared ... A pilot-scale airlift oxidation ditch using bubble diffuser and baffle as aerator was operated in a wastewater treatment plant(WWTP)to investigate its flow characteristic and wastewater treatment performance.Compared with the conventional oxidation ditch process,effective depth and oxygen utilization efficiency of this new process was improved by underwater aeration.Furthermore,it had a reversed velocity distribution,which decreased from the bottom to the top on vertical section.Velocity measurement showed that a velocity over 0.2 m/s at the bottom was sufficient to prevent sludge settlement during long term operation.Application of these concepts would save land area and energy consumption by about 25%–50%and 55%,respectively.In this new system,organic biodegradation and nitrification could be well achieved.Denitrification could occur steadily in the straight part by adjusting the airflow rate.An average TN removal rate of 63%was achieved with dissolved oxygen(DO)concentrations between 0.6 mg/L and 1.5 mg/L.The main pollutants in the effluent could meet the strictest discharge standard(COD<50 mg/L,NH4_(+)^(–)N<5 mg/L,and TN<15 mg/L)in China now. 展开更多
关键词 airlift oxidation ditch flow characteristic wastewater treatment
原文传递
西北某城镇污水处理厂提标改造实例
17
作者 尹博涵 黄宁俊 +3 位作者 王社平 张日霞 王继斌 王怡 《工业用水与废水》 2025年第3期92-95,100,共5页
西北某城镇污水处理厂设计规模为10×10^(4)m^(3)/d,生物处理采用卡鲁塞尔氧化沟工艺,现状出水水质执行GB 18918—2002《城镇污水处理厂污染物排放标准》中的一级A标准,提标后要求达到地表水准Ⅳ类水质要求。针对实际运行进水水质... 西北某城镇污水处理厂设计规模为10×10^(4)m^(3)/d,生物处理采用卡鲁塞尔氧化沟工艺,现状出水水质执行GB 18918—2002《城镇污水处理厂污染物排放标准》中的一级A标准,提标后要求达到地表水准Ⅳ类水质要求。针对实际运行进水水质与原设计水质存在偏差、现状氧化沟停留时间较短、无有效化学除磷设施及现状纤维转盘滤池运行不稳定的问题,确定采用扩容一期氧化沟、新建高密度沉淀池和反硝化深床滤池的提标改造工艺方案。运行结果表明,提标改造后污水处理厂运行稳定,出水水质达到设计要求。 展开更多
关键词 城镇污水 污水处理厂 脱氮除磷 提标改造 氧化沟 高密度沉淀池 反硝化深床滤池
在线阅读 下载PDF
表面曝气型氧化沟中N_(2)O产排特征与关键影响因素
18
作者 高嘉 宗倪 +10 位作者 刘健 赵楠 李群 常菁 袁星 齐嵘 肖淑敏 苏高新 窦殿程 朱浩宾 杨敏 《中国给水排水》 北大核心 2025年第19期95-101,共7页
对北方某大型城市污水处理厂表面曝气型氧化沟工艺进行了为期1年的氧化亚氮(N_(2)O)排放通量监测。结果显示,曝气区的N_(2)O气相排放因子比非曝气区高2~3个数量级,而两个区域的液相排放因子则处于同一量级;无论是曝气区还是非曝气区,N_(... 对北方某大型城市污水处理厂表面曝气型氧化沟工艺进行了为期1年的氧化亚氮(N_(2)O)排放通量监测。结果显示,曝气区的N_(2)O气相排放因子比非曝气区高2~3个数量级,而两个区域的液相排放因子则处于同一量级;无论是曝气区还是非曝气区,N_(2)O主要是以液相形式存在;从总排放因子来看,两区域均呈现出冬春季低、夏秋季高的趋势。双同位素溯源结果显示,曝气区与非曝气区的N_(2)O均来源于不同过程的混合:在以反硝化过程为主的非曝气区中可以测得有41.71%的N_(2)O来源于硝化过程,而曝气区中反硝化过程的贡献率达到了41.69%。N_(2)O排放因子的波动与进水NH_(4)^(+)-N浓度和C/N呈现显著相关。非曝气区与曝气区的活性污泥结构并无显著不同,活性污泥存在着一个相对稳定的微生物菌群,优势菌属Acinetobacter、Intestinibacter、Trichococcus均具有较高的代谢多样性和生存灵活性。这些结果为未来城市污水生物处理过程中N_(2)O的产排控制策略构建指明了主要关键因子与潜在控制方向。 展开更多
关键词 表面曝气型氧化沟 氧化亚氮 排放因子 关键影响因素 同位素溯源
原文传递
武汉市推进高质量污水处理绿色低碳标杆厂的典型项目设计 被引量:1
19
作者 郝学凯 王弘宇 +2 位作者 王臻琳 王俊 吴伟 《山西建筑》 2025年第10期27-30,61,共5页
武汉市某生活污水处理厂扩建工程,处理规模由10万m^(3)/d扩建至15万m^(3)/d,近期出水标准执行国标一级A标准,预留远期扩建至20万m^(3)/d及提标至地表水准Ⅳ类标准的条件。设计采用多点进水前置厌氧改良氧化沟(底曝)工艺,经工艺改良后,... 武汉市某生活污水处理厂扩建工程,处理规模由10万m^(3)/d扩建至15万m^(3)/d,近期出水标准执行国标一级A标准,预留远期扩建至20万m^(3)/d及提标至地表水准Ⅳ类标准的条件。设计采用多点进水前置厌氧改良氧化沟(底曝)工艺,经工艺改良后,污水处理单位经营成本为0.74元/t,吨水电耗为0.325 (kW·h)/t,消减1 kg OCTP电耗为1.457 kW·h,其中核心能耗设备较一二期节约能耗40%。污泥脱水处理选用了“机械浓缩+污泥调理+板框压滤+污泥协同焚烧”的工艺路线,同步实现了污泥减量化、无害化、资源化。该项目大力推进了可再生能源规模化应用,安装光伏面积不低于屋顶面积的50%,可再生能源应用量达107 514 (kW·h)/a,建筑总运行能源自给率达34%。 展开更多
关键词 绿色低碳 污水处理 多点进水改良氧化沟
在线阅读 下载PDF
传统氧化沟工艺城镇污水厂全流程微塑料去除率变化特征
20
作者 魏静凯 王伟 +3 位作者 孟鑫 齐杰 王兵帅 孙广垠 《环境科学》 北大核心 2025年第6期3450-3460,共11页
城市污水处理厂(WWTPs)被认为是微塑料进入自然水体的主要来源,且在发展中国家对于微塑料的研究仍处于初级阶段.以中国典型北方城市邯郸为对象,对该市一污水处理厂一期工程和扩建工程中全流程微塑料形状和粒径的去除率变化特征进行相关... 城市污水处理厂(WWTPs)被认为是微塑料进入自然水体的主要来源,且在发展中国家对于微塑料的研究仍处于初级阶段.以中国典型北方城市邯郸为对象,对该市一污水处理厂一期工程和扩建工程中全流程微塑料形状和粒径的去除率变化特征进行相关研究.结果表明:①污水处理厂进水中形状上以纤维状微塑料为主,粒径上以小于0.5 mm的微塑料为主;②各级处理中,二级处理对微塑料的去除起关键作用;③夏季一期工程和扩建工程的去除率分别达到90.20%和84.75%,冬季一期工程和扩建工程去除率分别达到93.75%和82.50%.尽管有如此高的去除效率,但由于庞大的日处理能力,仍有大量微塑料排放到最终水域.研究旨在为污水处理厂提升微塑料去除率的运行管理提供理论指导. 展开更多
关键词 城镇污水处理 氧化沟 微塑料(MPs) 去除率 赋存特征
原文传递