The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The measurement result...The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The measurement result of neutron flux monitoring(NFM)is a significant feedback parameter related to the acquisition of radiation protection-related information and rapid fluctuations in neutron emission induced by plasma magnetohydrodynamic activity.Therefore,a wide range and high time resolution are required for the NFM system on EAST.To satisfy these requirements,a digital pulse signal acquisition and processing system with a wide dynamic range and fast response time was developed.The present study was conducted using a field-programmable gate array(FPGA)and peripheral component interconnect extension for instrument express(PXIe)platform.The digital dual measurement modes,which are composed of the pulse-counting mode and AC coupled square integral's Campbelling mode,were designed to expand the measurement range of the signal acquisition and processing system.The time resolution of the signal acquisition and processing system was improved from 10 to 1 ms owing to utilizing highspeed analog-to-digital converters(ADCs),a high-speed PXIe communication with a direct memory access(DMA)mode,and online data preprocessing technology of FPGA.The signal acquisition and processing system was tested experimentally in the EAST radiation field.The test results showed that the time resolution of NFM was improved to 1 ms,and the dynamic range of the neutron counts rate was expanded to more than 10^(6) counts per second.The Campbelling mode was calibrated using a multipoint average linear fitting method;subsequently,the fitting coefficient reached 0.9911.Therefore,the newly developed pulse signal acquisition and processing system ensures that the NFM system meets the requirements of high-parameter experiments conducted on EAST more effectively.展开更多
This thesis addresses the issues existing in traditional laser tracking displacement measurement technology in the field of ultraprecision metrology by designing a differential signal processing circuit for high-preci...This thesis addresses the issues existing in traditional laser tracking displacement measurement technology in the field of ultraprecision metrology by designing a differential signal processing circuit for high-precision laser interferometric displacement measurement.A stable power supply module is designed to provide low-noise voltage to the entire circuit.An analog circuit system is constructed,including key circuits such as photoelectric sensors,I-V amplification,zero adjustment,fully differential amplification,and amplitude modulation filtering.To acquire and process signals,the PMAC Acc24E3 data acquisition card is selected,which realizes phase demodulation through reversible square wave counting,inverts displacement information,and a visual interface for the host computer is designed.Experimental verification shows that the designed system achieves micrometer-level measurement accuracy within a range of 0-10mm,with a maximum measurement error of less than 1.2μm,a maximum measurement speed of 6m/s,and a resolution better than 0.158μm.展开更多
Human physiological(biological)systems function in such a way that their complexity requires mathematical analysis.The functioning of the brain,heart and other parts are so complex to be easily comprehended.Under cond...Human physiological(biological)systems function in such a way that their complexity requires mathematical analysis.The functioning of the brain,heart and other parts are so complex to be easily comprehended.Under conditions of rest or work,the temporal distances of successive heartbeats are subject to fluctuations,thereby forming the basis of Heart Rate Variability(HRV).In normal conditions,the human is persistently exposed to highly changing and dynamic situational demands.With these demands in mind,HRV can,therefore,be considered as the human organism’s ability to cope with and adapt to continuous situational requirements,both physiologically and emotionally.Fast Fourier Transform(FFT)is used in various physiological signal processing,such as heart rate variability.FFT allows a spectral analysis of HRV and is great help in HRV analysis and interpretation.展开更多
Cavity beam position monitor(BPM) is widely used in a precise electron beam position measurement. Based on high performance oscilloscope-embedded EPICS input/output controller,we developed an on-line cavity BPM signal...Cavity beam position monitor(BPM) is widely used in a precise electron beam position measurement. Based on high performance oscilloscope-embedded EPICS input/output controller,we developed an on-line cavity BPM signal processing system for fast data acquisition solution when designing a cavity BPM.Also,methods for extracting the position information from cavity pickup signals and calibration algorithm are included in this solution.展开更多
An integrated monitoring system for running parameters of key mining equipmenton the basis of condition monitoring technology and modern communication networktechnology was developed.The system consists of a client co...An integrated monitoring system for running parameters of key mining equipmenton the basis of condition monitoring technology and modern communication networktechnology was developed.The system consists of a client computer with functions ofsignal acquisition and processing, and a host computer in the central control room.Thesignal acquisition module of the client computer can collect the running parameters fromvarious monitoring terminals in real-time.The DSP high-speed data processing system ofthe main control module can quickly achieve the numerical calculation for the collectedsignal.The signal modulation and signal demodulation are completed by the frequencyshift keying circuit and phase-locked loop frequency circuit, respectively.Finally, the signalis sent to the host computer for logic estimation and diagnostic analysis using the networkcommunication technology, which is helpful for technicians and managers to control therunning state of equipment.展开更多
Aiming at applications as a projectile-borne video reconnaissance system, the overall design and prototype in principle of a mortar video reconnaissance system bomb were developed. Mortar launched test results show th...Aiming at applications as a projectile-borne video reconnaissance system, the overall design and prototype in principle of a mortar video reconnaissance system bomb were developed. Mortar launched test results show that the initial integrated system was capable of transmitting images through tens of kilometers with the image resolution identifying effectively tactical targets such as roads, hills, caverns, trees and rivers. The projectile-borne video reconnaissance system is able to meet the needs of tactical target identification and battle damage assessment for tactical operations. The study will provide significant technological support for further independent development.展开更多
While the Ordos Basin is recognized for its substantial hydrocarbon exploration prospects,its rugged loess tableland terrain has rendered seismic exploration exceptionally challenging[1-3].Persistent obstacles such as...While the Ordos Basin is recognized for its substantial hydrocarbon exploration prospects,its rugged loess tableland terrain has rendered seismic exploration exceptionally challenging[1-3].Persistent obstacles such as complex 3D survey planning,low signal-tonoise ratio raw data,inadequate near-surface velocity modeling,and imaging inaccuracy have long hindered the advancement of seismic exploration across this region.Through a problem-solving approach rooted in geological target analysis,this research systematically investigates the behavioral patterns of nodal seismometer-based high-density seismic acquisition in loess plateau.Tailored advancements in waveform enhancement and depth velocity modelling methodologies have been engineered.Field validations confirm that the optimized workflow demonstrates marked improvements in amplitude preservation and imaging resolution,offering novel insights for future reservoir characterization endeavors.展开更多
基金supported by the Users with Excellence Program of the Hefei Science Center CAS (No. 2020HSC-UE012)
文摘The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The measurement result of neutron flux monitoring(NFM)is a significant feedback parameter related to the acquisition of radiation protection-related information and rapid fluctuations in neutron emission induced by plasma magnetohydrodynamic activity.Therefore,a wide range and high time resolution are required for the NFM system on EAST.To satisfy these requirements,a digital pulse signal acquisition and processing system with a wide dynamic range and fast response time was developed.The present study was conducted using a field-programmable gate array(FPGA)and peripheral component interconnect extension for instrument express(PXIe)platform.The digital dual measurement modes,which are composed of the pulse-counting mode and AC coupled square integral's Campbelling mode,were designed to expand the measurement range of the signal acquisition and processing system.The time resolution of the signal acquisition and processing system was improved from 10 to 1 ms owing to utilizing highspeed analog-to-digital converters(ADCs),a high-speed PXIe communication with a direct memory access(DMA)mode,and online data preprocessing technology of FPGA.The signal acquisition and processing system was tested experimentally in the EAST radiation field.The test results showed that the time resolution of NFM was improved to 1 ms,and the dynamic range of the neutron counts rate was expanded to more than 10^(6) counts per second.The Campbelling mode was calibrated using a multipoint average linear fitting method;subsequently,the fitting coefficient reached 0.9911.Therefore,the newly developed pulse signal acquisition and processing system ensures that the NFM system meets the requirements of high-parameter experiments conducted on EAST more effectively.
文摘This thesis addresses the issues existing in traditional laser tracking displacement measurement technology in the field of ultraprecision metrology by designing a differential signal processing circuit for high-precision laser interferometric displacement measurement.A stable power supply module is designed to provide low-noise voltage to the entire circuit.An analog circuit system is constructed,including key circuits such as photoelectric sensors,I-V amplification,zero adjustment,fully differential amplification,and amplitude modulation filtering.To acquire and process signals,the PMAC Acc24E3 data acquisition card is selected,which realizes phase demodulation through reversible square wave counting,inverts displacement information,and a visual interface for the host computer is designed.Experimental verification shows that the designed system achieves micrometer-level measurement accuracy within a range of 0-10mm,with a maximum measurement error of less than 1.2μm,a maximum measurement speed of 6m/s,and a resolution better than 0.158μm.
文摘Human physiological(biological)systems function in such a way that their complexity requires mathematical analysis.The functioning of the brain,heart and other parts are so complex to be easily comprehended.Under conditions of rest or work,the temporal distances of successive heartbeats are subject to fluctuations,thereby forming the basis of Heart Rate Variability(HRV).In normal conditions,the human is persistently exposed to highly changing and dynamic situational demands.With these demands in mind,HRV can,therefore,be considered as the human organism’s ability to cope with and adapt to continuous situational requirements,both physiologically and emotionally.Fast Fourier Transform(FFT)is used in various physiological signal processing,such as heart rate variability.FFT allows a spectral analysis of HRV and is great help in HRV analysis and interpretation.
基金Supported by National Natural Science Foundation(Grant No.11075198)
文摘Cavity beam position monitor(BPM) is widely used in a precise electron beam position measurement. Based on high performance oscilloscope-embedded EPICS input/output controller,we developed an on-line cavity BPM signal processing system for fast data acquisition solution when designing a cavity BPM.Also,methods for extracting the position information from cavity pickup signals and calibration algorithm are included in this solution.
基金Supported by the National Hi-tech Research and Development Program of China(2007AA04Z415)the Hunan Province and Xiangtan City Natural Science Joint Foundation(09JJ8005)the Torch Program Project of Hunan Province(2008SH044)
文摘An integrated monitoring system for running parameters of key mining equipmenton the basis of condition monitoring technology and modern communication networktechnology was developed.The system consists of a client computer with functions ofsignal acquisition and processing, and a host computer in the central control room.Thesignal acquisition module of the client computer can collect the running parameters fromvarious monitoring terminals in real-time.The DSP high-speed data processing system ofthe main control module can quickly achieve the numerical calculation for the collectedsignal.The signal modulation and signal demodulation are completed by the frequencyshift keying circuit and phase-locked loop frequency circuit, respectively.Finally, the signalis sent to the host computer for logic estimation and diagnostic analysis using the networkcommunication technology, which is helpful for technicians and managers to control therunning state of equipment.
文摘Aiming at applications as a projectile-borne video reconnaissance system, the overall design and prototype in principle of a mortar video reconnaissance system bomb were developed. Mortar launched test results show that the initial integrated system was capable of transmitting images through tens of kilometers with the image resolution identifying effectively tactical targets such as roads, hills, caverns, trees and rivers. The projectile-borne video reconnaissance system is able to meet the needs of tactical target identification and battle damage assessment for tactical operations. The study will provide significant technological support for further independent development.
文摘While the Ordos Basin is recognized for its substantial hydrocarbon exploration prospects,its rugged loess tableland terrain has rendered seismic exploration exceptionally challenging[1-3].Persistent obstacles such as complex 3D survey planning,low signal-tonoise ratio raw data,inadequate near-surface velocity modeling,and imaging inaccuracy have long hindered the advancement of seismic exploration across this region.Through a problem-solving approach rooted in geological target analysis,this research systematically investigates the behavioral patterns of nodal seismometer-based high-density seismic acquisition in loess plateau.Tailored advancements in waveform enhancement and depth velocity modelling methodologies have been engineered.Field validations confirm that the optimized workflow demonstrates marked improvements in amplitude preservation and imaging resolution,offering novel insights for future reservoir characterization endeavors.