To ensure an uninterrupted power supply,mobile power sources(MPS)are widely deployed in power grids during emergencies.Comprising mobile emergency generators(MEGs)and mobile energy storage systems(MESS),MPS are capabl...To ensure an uninterrupted power supply,mobile power sources(MPS)are widely deployed in power grids during emergencies.Comprising mobile emergency generators(MEGs)and mobile energy storage systems(MESS),MPS are capable of supplying power to critical loads and serving as backup sources during grid contingencies,offering advantages such as flexibility and high resilience through electricity delivery via transportation networks.This paper proposes a design method for a 400 V–10 kV Dual-Winding Induction Generator(DWIG)intended for MEG applications,employing an improved particle swarmoptimization(PSO)algorithmbased on a back-propagation neural network(BPNN).A parameterized finite element(FE)model of the DWIG is established to derive constraints on its dimensional parameters,thereby simplifying the optimization space.Through sensitivity analysis between temperature rise and electromagnetic loss of the DWIG,the main factors influencing the machine’s temperature are identified,and electromagnetic loss is determined as the optimization objective.To obtain an accurate fitting function between electromagnetic loss and dimensional parameters,the BPNN is employed to predict the nonlinear relationship between the optimization objective and the parameters.The Latin hypercube sampling(LHS)method is used for random sampling in the FE model analysis for training,testing,and validation,which is then applied to compute the cost function in the PSO.Based on the relationships obtained by the BPNN,the PSO algorithm evaluates the fitness and cost functions to determine the optimal design point.The proposed optimization method is validated by comparing simulation results between the initial design and the optimized design.展开更多
Inertial response control(IRC)makes variable-speed wind turbine generators(WTGs)provide short-term frequency support during contingencies by releasing the kinetic energy stored in wind turbine rotors.When frequency su...Inertial response control(IRC)makes variable-speed wind turbine generators(WTGs)provide short-term frequency support during contingencies by releasing the kinetic energy stored in wind turbine rotors.When frequency support is terminated,the rotor speed should be restored to optimum for maximum power point tracking(MPPT).Existing IRCs utilize rotor speed recovery(RSR)strategies with a consistent power reference function.However,under real turbulent wind with alternate gusts and lulls,the consistent power reference function may fail to restore rotor speed or cause unexpected secondary frequency drop(SFD).In this regard,this paper proposes a novel adaptive RSR strategy that not only restores rotor speed via the aerodynamic power enhanced by wind gusts,but also stabilizes the turbine at wind lulls by tracking a suboptimal power curve.Experiments on a wind power-integrated power system testbed validate the proposed RSR strategy can successfully restore rotor speed while attenuating SFD under turbulent wind.展开更多
New renewable energy exploitation technologies in offshore structures are vital for future energy production systems.Offshore hybrid wind-wave power generation(HWWPG)systems face increased component failure rates beca...New renewable energy exploitation technologies in offshore structures are vital for future energy production systems.Offshore hybrid wind-wave power generation(HWWPG)systems face increased component failure rates because of harsh weather,significantly affecting the maintenance procedures and reliability.Different types of failure rates of the wind turbine(WT)and wave energy converter(WEC),e.g.,the degradation and failure rates during regular wind speed fluctuation,the degradation and failure rates during intense wind speed fluctuation are considered.By incorporating both WT and WEC,the HWWPG system is designed to enhance the overall amount of electrical energy produced by the system over a given period under varying weather conditions.The universal generating function technique is used to calculate the HWWPG system dependability measures in a structured and efficient manner.This research highlights that intense weather conditions increase the failure rates of both WT and WEC,resulting in higher maintenance costs and more frequent downtimes,thus impacting the HWWPG system’s reliability.Although the HWWPG system can meet the energy demands in the presence of high failure rates,the reliance of the hybrid system on both WT and WEC helps maintain a relatively stable demand satisfaction during periods of high energy demand despite adverse weather conditions.To confirm the added value and applicability of the developed model,a case study of an offshore hybrid platform is conducted.The findings underscore the system’s robustness in maintaining energy production under varied weather conditions,though higher failure rates and maintenance costs arise in intense scenarios.展开更多
A wind-turbine power system is often challenged by voltage instability,reactive power imbalance,and limited fault ride-through capability under grid disturbances.Doubly Fed Induction Generator based wind farms,owing t...A wind-turbine power system is often challenged by voltage instability,reactive power imbalance,and limited fault ride-through capability under grid disturbances.Doubly Fed Induction Generator based wind farms,owing to their partial coupling with the grid,are particularly vulnerable to voltage dips and excessive reactive power absorption during fault events.This study proposes an adaptive control strategy based on Model Reference Adaptive Control integrated with stator flux-oriented vector control to regulate active and reactive power of a DFIG-based wind farm connected to a standard IEEE 9-bus power system under fault conditions.The proposed control scheme is developed and validated using detailed MATLAB/Simulink modeling under normal operation,symmetrical three-phase fault conditions,and post-fault recovery scenarios.A three-phase-to-ground fault is applied at the wind farm interconnection bus for a duration of 150 ms to evaluate transient performance.Simulation results demonstrate that the adaptive controller ensures fast power tracking,effective reactive power support,and enhanced voltage recovery compared to a conventional proportional–integral controller.Quantitatively,the proposed method improves voltage recovery time by approximately 45%,reduces active power overshoot by 38%,and lowers total harmonic distortion by 52% following fault clearance.Furthermore,the adaptive controller maintains stable operation under variations in wind speed and machine parameters without requiring retuning,highlighting its robustness against system uncertainties.The results confirm that the proposed control strategy significantly enhances fault ride-through capability,power quality,and dynamic stability of grid-interfaced wind farms.These findings demonstrate the practical applicability of adaptive control techniques for improving the reliability and resilience of modern power systems with high wind energy penetration.展开更多
An optimized volt-ampere reactive(VAR)control framework is proposed for transmission-level power systems to simultaneously mitigate voltage deviations and active-power losses through coordinated control of large-scale...An optimized volt-ampere reactive(VAR)control framework is proposed for transmission-level power systems to simultaneously mitigate voltage deviations and active-power losses through coordinated control of large-scale wind/solar farms with shunt static var generators(SVGs).The model explicitly represents reactive-power regulation characteristics of doubly-fed wind turbines and PV inverters under real-time meteorological conditions,and quantifies SVG high-speed compensation capability,enabling seamless transition from localized VAR management to a globally coordinated strategy.An enhanced adaptive gain-sharing knowledge optimizer(AGSK-SD)integrates simulated annealing and diversity maintenance to autonomously tune voltage-control actions,renewable source reactive-power set-points,and SVG output.The algorithm adaptively modulates knowledge factors and ratios across search phases,performs SA-based fine-grained local exploitation,and periodically re-injects population diversity to prevent premature convergence.Comprehensive tests on IEEE 9-bus and 39-bus systems demonstrate AGSK-SD’s superiority over NSGA-II and MOPSO in hypervolume(HV),inverse generative distance(IGD),and spread metrics while maintaining acceptable computational burden.The method reduces network losses from 2.7191 to 2.15 MW(20.79%reduction)and from 15.1891 to 11.22 MW(26.16%reduction)in the 9-bus and 39-bus systems respectively.Simultaneously,the cumulative voltage-deviation index decreases from 0.0277 to 3.42×10^(−4) p.u.(98.77%reduction)in the 9-bus system,and from 0.0556 to 0.0107 p.u.(80.76%reduction)in the 39-bus system.These improvements demonstrate significant suppression of line losses and voltage fluctuations.Comparative analysis with traditional heuristic optimization algorithms confirms the superior performance of the proposed approach.展开更多
Due to randomness of wind generator's availability, power system planners have big concern on EEG (expected energy generation) and system reliability of power system with wind generators. This paper presents a meth...Due to randomness of wind generator's availability, power system planners have big concern on EEG (expected energy generation) and system reliability of power system with wind generators. This paper presents a methodology to evaluate the EEG as well as overall LOLP (loss of load probability), which is an index for system reliability of multi-area interconnected systems with wind generators, as well as conventional fossil fuel based generating units. The proposed model is also capable of tracking the energy export incorporating the multi-state probability model for wind generator which output varies with time and season.展开更多
In recent years, there has been introduction of alternative energy sources such as wind energy. However, wind speed is not constant and wind power output is proportional to the cube of the wind speed. In order to cont...In recent years, there has been introduction of alternative energy sources such as wind energy. However, wind speed is not constant and wind power output is proportional to the cube of the wind speed. In order to control the power output for wind power generators as accurately as possible, a method of wind speed estimation is required. In this paper, a technique considers that wind speed in the order of 1 - 30 seconds is investigated in confirming the validity of the Auto Regressive model (AR), Kalman Filter (KF) and Neural Network (NN) to forecast wind speed. This paper compares the simulation results of the forecast wind speed for the power output forecast of wind power generator by using AR, KF and NN.展开更多
Due to environmental conditions, the wind power generation is fluctuating in nature. This affects the electrical network interconnected with these systems. When the wind power generators are connected to the nonlinear...Due to environmental conditions, the wind power generation is fluctuating in nature. This affects the electrical network interconnected with these systems. When the wind power generators are connected to the nonlinear loads, there is distortion in the waveform. These distortions should be within limits according to national and international guidelines framed for power quality. This paper presents a mitigation technique with a shunt active filter, which reduces harmonic distortion to the permitted limit. Sine pulse width modulation (SPWM) control scheme is used to control shunt active filter. This technique eliminates harmonic distortion and maintains unity power factor. The simulation for proposed method is carried out using MATLAB/SIMULINK and results are validated.展开更多
Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding ...Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding of a synchronous generator,a gate recurrent unit-convolutional neural network(GRU-CNN)model whose structural parameters were determined by improved particle swarm optimization(IPSO)is proposed.The outputs of the model are the excitation current and reactive power.The total offset distance,which is the fusion of the offset distance of the excitation current and offset distance of the reactive power,was selected as the fault judgment criterion.The fusion weights of the excitation current and reactive power were determined using the anti-entropy weighting method.The fault-warning threshold and fault-warning ratio were set according to the normal total offset distance,and the fault warning time was set according to the actual situation.The fault-warning time and fault-warning ratio were used to avoid misdiagnosis.The proposed method was verified experimentally.展开更多
The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, th...The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, the rotor speed is set at an optimal point for different wind speeds. As a result of which, the tip speed ratio reaches an optimal point, mechanical power coefficient is maximized, and wind turbine produces its maximum power and mechanical torque. Then, the maximum mechanical torque is tracked using electromechanical torque. In this technique, tracking error integral of maximum mechanical torque, the error, and the derivative of error are used as state variables. During changes in wind speed, sliding mode control is designed to absorb the maximum energy from the wind and minimize the response time of maximum power point tracking(MPPT). In this method, the actual control input signal is formed from a second order integral operation of the original sliding mode control input signal. The result of the second order integral in this model includes control signal integrity, full chattering attenuation, and prevention from large fluctuations in the power generator output. The simulation results, calculated by using MATLAB/m-file software, have shown the effectiveness of the proposed control strategy for wind energy systems based on the permanent magnet synchronous generator(PMSG).展开更多
This paper gives performance analysis of a three phase Permanent Magnet Synchronous Generator (PMSG) connected to a Vertical Axis Wind Turbine (VAWT). Low speed wind condition (less than 5 m/s) is taken in considerati...This paper gives performance analysis of a three phase Permanent Magnet Synchronous Generator (PMSG) connected to a Vertical Axis Wind Turbine (VAWT). Low speed wind condition (less than 5 m/s) is taken in consideration and the entire simulation is carried in Matlab/Simulink environment. The rated power for the generator is fixed at 1.5 KW and number of pole at 20. It is observed under low wind speed of6 m/s, a turbine having approximately1 mof radius and2.6 mof height develops 150 Nm mechanical torque that can generate power up to 1.5 KW. The generator is designed using modeling tool and is fabricated. The fabricated generator is tested in the laboratory with the simulation result for the error analysis. The range of error is about 5%-27% for the same output power value. The limitations and possible causes for error are presented and discussed.展开更多
An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of D...An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of DFIG, the modeling for electromagnetic calculation of DFIG was proposed. The electromagnetic calculation of DFIG was divided into three steps: the magnetic flux calculation, parameters derivation and performance checks. For each step, the detailed numeric calculation formulas were all derived. Combining the calculation formulas, the whole electromagnetic calculation procedure was established, which consisted of three iterative calculation loops, including magnetic saturation coefficient, electromotive force and total output power. All of the electromagnetic and performance data of DIFG can be calculated conveniently by the established calculation procedure, which can be used to evaluate the new designed machine. A 1.5 MW DFIG designed by the proposed procedure was built, for which the whole type tests including no-load test, load test and temperature rising test were carried out. The test results have shown that the DFIG satisfies technical requirements and the test data fit well with the calculation results which prove the correctness of the presented calculation method.展开更多
This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based.This controller uses the state space equations th...This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based.This controller uses the state space equations that consider the rotor current and voltage as state and control variables,to execute the predictive control action.Therefore,the model of the plant must be transformed into two discrete transference functions,by means of an auto-regressive moving average model,in order to attain a discrete and decoupled controller,which makes it possible to treat it as two independent single-input single-output systems instead of a magnetic coupled multiple-input multiple-output system.For achieving that,a direct power control strategy is used,based on the past and future rotor currents and voltages estimation.The algorithm evaluates the rotor current predictors for a defined prediction horizon and computes the new rotor voltages that must be injected to controlling the stator active and reactive powers.To evaluate the controller performance,some simulations were made using Matlab/Simulink.Experimental tests were carried out with a small-scale prototype assuming normal operating conditions with constant and variable wind speed profiles.Finally,some conclusions respect to the dynamic performance of this new controller are summarized.展开更多
In China, regions with abundant wind energy resources are generally located at the end of power grids. The power grid architecture in these regions is typically not sufficiently strong, and the energy structure is rel...In China, regions with abundant wind energy resources are generally located at the end of power grids. The power grid architecture in these regions is typically not sufficiently strong, and the energy structure is relatively simple. Thus, connecting large-capacity wind power units complicates the peak load regulation and stable operation of the power grids in these regions. Most wind turbines use power electronic converter technology, which affects the safety and stability of the power grid differently compared with conventional synchronous generators. Furthermore, fluctuations in wind power cause fluctuations in the output of wind farms, making it difficult to create and implement suitable power generation plans for wind farms. The generation technology and grid connection scheme for wind power and conventional thermal power generation differ considerably. Moreover, the active and reactive power control abilities of wind turbines are weaker than those of thermal power units, necessitating additional equipment to control wind turbines. Hence, to address the aforementioned issues with large-scale wind power generation, this study analyzes the differences between the grid connection and collection strategies for wind power bases and thermal power plants. Based on this analysis, the differences in the power control modes of wind power and thermal power are further investigated. Finally, the stability of different control modes is analyzed through simulation. The findings can be beneficial for the planning and development of large-scale wind power generation farms.展开更多
The wind energy generation,utilization and its grid penetration in electrical grid are increasing world-wide.The wind generated power is always fluctuating due to its time varying nature and causing stability problem....The wind energy generation,utilization and its grid penetration in electrical grid are increasing world-wide.The wind generated power is always fluctuating due to its time varying nature and causing stability problem.This weak interconnection of wind generating source in the electrical network affects the power quality and reliability.The localized energy storages shall compensate the fluctuating power and support to strengthen the wind generator in the power system.In this paper,it is proposed to control the voltage source inverter (VSI) in current control mode with energy storage,that is,batteries across the dc bus.The generated wind power can be extracted under varying wind speed and stored in the batteries.This energy storage maintains the stiff voltage across the dc bus of the voltage source inverter.The proposed scheme enhances the stability and reliability of the power system and maintains unity power factor.It can also be operated in stand-alone mode in the power system.The power exchange across the wind generation and the load under dynamic situation is feasible while maintaining the power quality norms at the common point of coupling.It strengthens the weak grid in the power system.This control strategy is evaluated on the test system under dynamic condition by using simulation.The results are verified by comparing the performance of controllers.展开更多
With the rapid increase of wind farms,the grid code needs to be improved to meet the requirement of wind farms and enhance grid stability.Doubly-fed induction generators are largely used in wind turbines,but they are ...With the rapid increase of wind farms,the grid code needs to be improved to meet the requirement of wind farms and enhance grid stability.Doubly-fed induction generators are largely used in wind turbines,but they are very sensitive to grid disturbances.The voltage swell can be caused by switching on capacitor banks or switching off large loads,which may result in the reversal of the power flow in the grid convertor;the current may flow from the grid into the DC link,which may step up DC voltage,and result in large faults of rotor currents and instantaneous power oscillation.The grid reactive compensation devices can not have the automatic swithing function after the low voltage fault,which will result in local reactive power surplus,so some wind power generators will retreat from the grid under high voltage protection.展开更多
According to the increasing requirement of the wind energy utilization and the dynamic stability in the variable speed variable pitch wind power generation system, a linear parameter varying (LPV) system model is es...According to the increasing requirement of the wind energy utilization and the dynamic stability in the variable speed variable pitch wind power generation system, a linear parameter varying (LPV) system model is established and a new adaptive robust guaranteed cost controller (AGCC) is proposed in this paper. First, the uncertain parameters of the system are estimated by using the adaptive method, then the estimated uncertain parameters and robust guaranteed cost control method are used to design a state feedback controller. The controller s feedback gain is obtained by solving a set of linear matrix inequality (LMI) constraints, such that the controller can meet a quadratic performance evaluation criterion. The simulation results show that we can realize the goal of maximum wind energy capture in low wind speed by the optimal torque control and constant power control in high wind speed by variable pitch control with good dynamic characteristics, robustness and the ability of suppressing disturbance.展开更多
Randomness and fluctuations in wind power output may cause changes in important parameters(e.g.,grid frequency and voltage),which in turn affect the stable operation of a power system.However,owing to external factors...Randomness and fluctuations in wind power output may cause changes in important parameters(e.g.,grid frequency and voltage),which in turn affect the stable operation of a power system.However,owing to external factors(such as weather),there are often various anomalies in wind power data,such as missing numerical values and unreasonable data.This significantly affects the accuracy of wind power generation predictions and operational decisions.Therefore,developing and applying reliable wind power interpolation methods is important for promoting the sustainable development of the wind power industry.In this study,the causes of abnormal data in wind power generation were first analyzed from a practical perspective.Second,an improved complete ensemble empirical mode decomposition with adaptive noise(ICEEMDAN)method with a generative adversarial interpolation network(GAIN)network was proposed to preprocess wind power generation and interpolate missing wind power generation sub-components.Finally,a complete wind power generation time series was reconstructed.Compared to traditional methods,the proposed ICEEMDAN-GAIN combination interpolation model has a higher interpolation accuracy and can effectively reduce the error impact caused by wind power generation sequence fluctuations.展开更多
基金funded by the Science and Technology Projects of State Grid Corporation of China(Project No.J2024136).
文摘To ensure an uninterrupted power supply,mobile power sources(MPS)are widely deployed in power grids during emergencies.Comprising mobile emergency generators(MEGs)and mobile energy storage systems(MESS),MPS are capable of supplying power to critical loads and serving as backup sources during grid contingencies,offering advantages such as flexibility and high resilience through electricity delivery via transportation networks.This paper proposes a design method for a 400 V–10 kV Dual-Winding Induction Generator(DWIG)intended for MEG applications,employing an improved particle swarmoptimization(PSO)algorithmbased on a back-propagation neural network(BPNN).A parameterized finite element(FE)model of the DWIG is established to derive constraints on its dimensional parameters,thereby simplifying the optimization space.Through sensitivity analysis between temperature rise and electromagnetic loss of the DWIG,the main factors influencing the machine’s temperature are identified,and electromagnetic loss is determined as the optimization objective.To obtain an accurate fitting function between electromagnetic loss and dimensional parameters,the BPNN is employed to predict the nonlinear relationship between the optimization objective and the parameters.The Latin hypercube sampling(LHS)method is used for random sampling in the FE model analysis for training,testing,and validation,which is then applied to compute the cost function in the PSO.Based on the relationships obtained by the BPNN,the PSO algorithm evaluates the fitness and cost functions to determine the optimal design point.The proposed optimization method is validated by comparing simulation results between the initial design and the optimized design.
基金supported by National Natural Science Foundation of China(51977111)the Six Talent Peaks High-level Talent Project in Jiangsu Province(XNY-025)the Special Fund of Jiangsu Province for Transformation of Scientific and Technological Achievements(BA2019045).
文摘Inertial response control(IRC)makes variable-speed wind turbine generators(WTGs)provide short-term frequency support during contingencies by releasing the kinetic energy stored in wind turbine rotors.When frequency support is terminated,the rotor speed should be restored to optimum for maximum power point tracking(MPPT).Existing IRCs utilize rotor speed recovery(RSR)strategies with a consistent power reference function.However,under real turbulent wind with alternate gusts and lulls,the consistent power reference function may fail to restore rotor speed or cause unexpected secondary frequency drop(SFD).In this regard,this paper proposes a novel adaptive RSR strategy that not only restores rotor speed via the aerodynamic power enhanced by wind gusts,but also stabilizes the turbine at wind lulls by tracking a suboptimal power curve.Experiments on a wind power-integrated power system testbed validate the proposed RSR strategy can successfully restore rotor speed while attenuating SFD under turbulent wind.
文摘New renewable energy exploitation technologies in offshore structures are vital for future energy production systems.Offshore hybrid wind-wave power generation(HWWPG)systems face increased component failure rates because of harsh weather,significantly affecting the maintenance procedures and reliability.Different types of failure rates of the wind turbine(WT)and wave energy converter(WEC),e.g.,the degradation and failure rates during regular wind speed fluctuation,the degradation and failure rates during intense wind speed fluctuation are considered.By incorporating both WT and WEC,the HWWPG system is designed to enhance the overall amount of electrical energy produced by the system over a given period under varying weather conditions.The universal generating function technique is used to calculate the HWWPG system dependability measures in a structured and efficient manner.This research highlights that intense weather conditions increase the failure rates of both WT and WEC,resulting in higher maintenance costs and more frequent downtimes,thus impacting the HWWPG system’s reliability.Although the HWWPG system can meet the energy demands in the presence of high failure rates,the reliance of the hybrid system on both WT and WEC helps maintain a relatively stable demand satisfaction during periods of high energy demand despite adverse weather conditions.To confirm the added value and applicability of the developed model,a case study of an offshore hybrid platform is conducted.The findings underscore the system’s robustness in maintaining energy production under varied weather conditions,though higher failure rates and maintenance costs arise in intense scenarios.
文摘A wind-turbine power system is often challenged by voltage instability,reactive power imbalance,and limited fault ride-through capability under grid disturbances.Doubly Fed Induction Generator based wind farms,owing to their partial coupling with the grid,are particularly vulnerable to voltage dips and excessive reactive power absorption during fault events.This study proposes an adaptive control strategy based on Model Reference Adaptive Control integrated with stator flux-oriented vector control to regulate active and reactive power of a DFIG-based wind farm connected to a standard IEEE 9-bus power system under fault conditions.The proposed control scheme is developed and validated using detailed MATLAB/Simulink modeling under normal operation,symmetrical three-phase fault conditions,and post-fault recovery scenarios.A three-phase-to-ground fault is applied at the wind farm interconnection bus for a duration of 150 ms to evaluate transient performance.Simulation results demonstrate that the adaptive controller ensures fast power tracking,effective reactive power support,and enhanced voltage recovery compared to a conventional proportional–integral controller.Quantitatively,the proposed method improves voltage recovery time by approximately 45%,reduces active power overshoot by 38%,and lowers total harmonic distortion by 52% following fault clearance.Furthermore,the adaptive controller maintains stable operation under variations in wind speed and machine parameters without requiring retuning,highlighting its robustness against system uncertainties.The results confirm that the proposed control strategy significantly enhances fault ride-through capability,power quality,and dynamic stability of grid-interfaced wind farms.These findings demonstrate the practical applicability of adaptive control techniques for improving the reliability and resilience of modern power systems with high wind energy penetration.
基金supported by Yunnan Power Grid Co.,Ltd.Science and Technology Project:Research and application of key technologies for graphical-based power grid accident reconstruction and simulation(YNKJXM20240333).
文摘An optimized volt-ampere reactive(VAR)control framework is proposed for transmission-level power systems to simultaneously mitigate voltage deviations and active-power losses through coordinated control of large-scale wind/solar farms with shunt static var generators(SVGs).The model explicitly represents reactive-power regulation characteristics of doubly-fed wind turbines and PV inverters under real-time meteorological conditions,and quantifies SVG high-speed compensation capability,enabling seamless transition from localized VAR management to a globally coordinated strategy.An enhanced adaptive gain-sharing knowledge optimizer(AGSK-SD)integrates simulated annealing and diversity maintenance to autonomously tune voltage-control actions,renewable source reactive-power set-points,and SVG output.The algorithm adaptively modulates knowledge factors and ratios across search phases,performs SA-based fine-grained local exploitation,and periodically re-injects population diversity to prevent premature convergence.Comprehensive tests on IEEE 9-bus and 39-bus systems demonstrate AGSK-SD’s superiority over NSGA-II and MOPSO in hypervolume(HV),inverse generative distance(IGD),and spread metrics while maintaining acceptable computational burden.The method reduces network losses from 2.7191 to 2.15 MW(20.79%reduction)and from 15.1891 to 11.22 MW(26.16%reduction)in the 9-bus and 39-bus systems respectively.Simultaneously,the cumulative voltage-deviation index decreases from 0.0277 to 3.42×10^(−4) p.u.(98.77%reduction)in the 9-bus system,and from 0.0556 to 0.0107 p.u.(80.76%reduction)in the 39-bus system.These improvements demonstrate significant suppression of line losses and voltage fluctuations.Comparative analysis with traditional heuristic optimization algorithms confirms the superior performance of the proposed approach.
文摘Due to randomness of wind generator's availability, power system planners have big concern on EEG (expected energy generation) and system reliability of power system with wind generators. This paper presents a methodology to evaluate the EEG as well as overall LOLP (loss of load probability), which is an index for system reliability of multi-area interconnected systems with wind generators, as well as conventional fossil fuel based generating units. The proposed model is also capable of tracking the energy export incorporating the multi-state probability model for wind generator which output varies with time and season.
文摘In recent years, there has been introduction of alternative energy sources such as wind energy. However, wind speed is not constant and wind power output is proportional to the cube of the wind speed. In order to control the power output for wind power generators as accurately as possible, a method of wind speed estimation is required. In this paper, a technique considers that wind speed in the order of 1 - 30 seconds is investigated in confirming the validity of the Auto Regressive model (AR), Kalman Filter (KF) and Neural Network (NN) to forecast wind speed. This paper compares the simulation results of the forecast wind speed for the power output forecast of wind power generator by using AR, KF and NN.
文摘Due to environmental conditions, the wind power generation is fluctuating in nature. This affects the electrical network interconnected with these systems. When the wind power generators are connected to the nonlinear loads, there is distortion in the waveform. These distortions should be within limits according to national and international guidelines framed for power quality. This paper presents a mitigation technique with a shunt active filter, which reduces harmonic distortion to the permitted limit. Sine pulse width modulation (SPWM) control scheme is used to control shunt active filter. This technique eliminates harmonic distortion and maintains unity power factor. The simulation for proposed method is carried out using MATLAB/SIMULINK and results are validated.
文摘Synchronous generators are important components of power systems and are necessary to maintain its normal and stable operation.To perform the fault diagnosis of mild inter-turn short circuit in the excitation winding of a synchronous generator,a gate recurrent unit-convolutional neural network(GRU-CNN)model whose structural parameters were determined by improved particle swarm optimization(IPSO)is proposed.The outputs of the model are the excitation current and reactive power.The total offset distance,which is the fusion of the offset distance of the excitation current and offset distance of the reactive power,was selected as the fault judgment criterion.The fusion weights of the excitation current and reactive power were determined using the anti-entropy weighting method.The fault-warning threshold and fault-warning ratio were set according to the normal total offset distance,and the fault warning time was set according to the actual situation.The fault-warning time and fault-warning ratio were used to avoid misdiagnosis.The proposed method was verified experimentally.
文摘The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, the rotor speed is set at an optimal point for different wind speeds. As a result of which, the tip speed ratio reaches an optimal point, mechanical power coefficient is maximized, and wind turbine produces its maximum power and mechanical torque. Then, the maximum mechanical torque is tracked using electromechanical torque. In this technique, tracking error integral of maximum mechanical torque, the error, and the derivative of error are used as state variables. During changes in wind speed, sliding mode control is designed to absorb the maximum energy from the wind and minimize the response time of maximum power point tracking(MPPT). In this method, the actual control input signal is formed from a second order integral operation of the original sliding mode control input signal. The result of the second order integral in this model includes control signal integrity, full chattering attenuation, and prevention from large fluctuations in the power generator output. The simulation results, calculated by using MATLAB/m-file software, have shown the effectiveness of the proposed control strategy for wind energy systems based on the permanent magnet synchronous generator(PMSG).
文摘This paper gives performance analysis of a three phase Permanent Magnet Synchronous Generator (PMSG) connected to a Vertical Axis Wind Turbine (VAWT). Low speed wind condition (less than 5 m/s) is taken in consideration and the entire simulation is carried in Matlab/Simulink environment. The rated power for the generator is fixed at 1.5 KW and number of pole at 20. It is observed under low wind speed of6 m/s, a turbine having approximately1 mof radius and2.6 mof height develops 150 Nm mechanical torque that can generate power up to 1.5 KW. The generator is designed using modeling tool and is fabricated. The fabricated generator is tested in the laboratory with the simulation result for the error analysis. The range of error is about 5%-27% for the same output power value. The limitations and possible causes for error are presented and discussed.
基金Project(2011DFA62240) supported by the International Scientific and Technological Cooperation Projects,ChinaProject(019945-SES6) supported by the European Union(EU)6th Framework Program UP-WIND Project,Denmark
文摘An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of DFIG, the modeling for electromagnetic calculation of DFIG was proposed. The electromagnetic calculation of DFIG was divided into three steps: the magnetic flux calculation, parameters derivation and performance checks. For each step, the detailed numeric calculation formulas were all derived. Combining the calculation formulas, the whole electromagnetic calculation procedure was established, which consisted of three iterative calculation loops, including magnetic saturation coefficient, electromotive force and total output power. All of the electromagnetic and performance data of DIFG can be calculated conveniently by the established calculation procedure, which can be used to evaluate the new designed machine. A 1.5 MW DFIG designed by the proposed procedure was built, for which the whole type tests including no-load test, load test and temperature rising test were carried out. The test results have shown that the DFIG satisfies technical requirements and the test data fit well with the calculation results which prove the correctness of the presented calculation method.
文摘This paper presents a new Long-range generalized predictive controller in the synchronous reference frame for a wind energy system doubly-fed induction generator based.This controller uses the state space equations that consider the rotor current and voltage as state and control variables,to execute the predictive control action.Therefore,the model of the plant must be transformed into two discrete transference functions,by means of an auto-regressive moving average model,in order to attain a discrete and decoupled controller,which makes it possible to treat it as two independent single-input single-output systems instead of a magnetic coupled multiple-input multiple-output system.For achieving that,a direct power control strategy is used,based on the past and future rotor currents and voltages estimation.The algorithm evaluates the rotor current predictors for a defined prediction horizon and computes the new rotor voltages that must be injected to controlling the stator active and reactive powers.To evaluate the controller performance,some simulations were made using Matlab/Simulink.Experimental tests were carried out with a small-scale prototype assuming normal operating conditions with constant and variable wind speed profiles.Finally,some conclusions respect to the dynamic performance of this new controller are summarized.
基金This work was supported by National Key Research and Development Program of China(2018YFB0904000).
文摘In China, regions with abundant wind energy resources are generally located at the end of power grids. The power grid architecture in these regions is typically not sufficiently strong, and the energy structure is relatively simple. Thus, connecting large-capacity wind power units complicates the peak load regulation and stable operation of the power grids in these regions. Most wind turbines use power electronic converter technology, which affects the safety and stability of the power grid differently compared with conventional synchronous generators. Furthermore, fluctuations in wind power cause fluctuations in the output of wind farms, making it difficult to create and implement suitable power generation plans for wind farms. The generation technology and grid connection scheme for wind power and conventional thermal power generation differ considerably. Moreover, the active and reactive power control abilities of wind turbines are weaker than those of thermal power units, necessitating additional equipment to control wind turbines. Hence, to address the aforementioned issues with large-scale wind power generation, this study analyzes the differences between the grid connection and collection strategies for wind power bases and thermal power plants. Based on this analysis, the differences in the power control modes of wind power and thermal power are further investigated. Finally, the stability of different control modes is analyzed through simulation. The findings can be beneficial for the planning and development of large-scale wind power generation farms.
文摘The wind energy generation,utilization and its grid penetration in electrical grid are increasing world-wide.The wind generated power is always fluctuating due to its time varying nature and causing stability problem.This weak interconnection of wind generating source in the electrical network affects the power quality and reliability.The localized energy storages shall compensate the fluctuating power and support to strengthen the wind generator in the power system.In this paper,it is proposed to control the voltage source inverter (VSI) in current control mode with energy storage,that is,batteries across the dc bus.The generated wind power can be extracted under varying wind speed and stored in the batteries.This energy storage maintains the stiff voltage across the dc bus of the voltage source inverter.The proposed scheme enhances the stability and reliability of the power system and maintains unity power factor.It can also be operated in stand-alone mode in the power system.The power exchange across the wind generation and the load under dynamic situation is feasible while maintaining the power quality norms at the common point of coupling.It strengthens the weak grid in the power system.This control strategy is evaluated on the test system under dynamic condition by using simulation.The results are verified by comparing the performance of controllers.
文摘With the rapid increase of wind farms,the grid code needs to be improved to meet the requirement of wind farms and enhance grid stability.Doubly-fed induction generators are largely used in wind turbines,but they are very sensitive to grid disturbances.The voltage swell can be caused by switching on capacitor banks or switching off large loads,which may result in the reversal of the power flow in the grid convertor;the current may flow from the grid into the DC link,which may step up DC voltage,and result in large faults of rotor currents and instantaneous power oscillation.The grid reactive compensation devices can not have the automatic swithing function after the low voltage fault,which will result in local reactive power surplus,so some wind power generators will retreat from the grid under high voltage protection.
基金supported by Natural Science Foundation of Hebei Province(No. F2012203088)
文摘According to the increasing requirement of the wind energy utilization and the dynamic stability in the variable speed variable pitch wind power generation system, a linear parameter varying (LPV) system model is established and a new adaptive robust guaranteed cost controller (AGCC) is proposed in this paper. First, the uncertain parameters of the system are estimated by using the adaptive method, then the estimated uncertain parameters and robust guaranteed cost control method are used to design a state feedback controller. The controller s feedback gain is obtained by solving a set of linear matrix inequality (LMI) constraints, such that the controller can meet a quadratic performance evaluation criterion. The simulation results show that we can realize the goal of maximum wind energy capture in low wind speed by the optimal torque control and constant power control in high wind speed by variable pitch control with good dynamic characteristics, robustness and the ability of suppressing disturbance.
基金We gratefully acknowledge the support of National Natural Science Foundation of China(NSFC)(Grant No.51977133&Grant No.U2066209).
文摘Randomness and fluctuations in wind power output may cause changes in important parameters(e.g.,grid frequency and voltage),which in turn affect the stable operation of a power system.However,owing to external factors(such as weather),there are often various anomalies in wind power data,such as missing numerical values and unreasonable data.This significantly affects the accuracy of wind power generation predictions and operational decisions.Therefore,developing and applying reliable wind power interpolation methods is important for promoting the sustainable development of the wind power industry.In this study,the causes of abnormal data in wind power generation were first analyzed from a practical perspective.Second,an improved complete ensemble empirical mode decomposition with adaptive noise(ICEEMDAN)method with a generative adversarial interpolation network(GAIN)network was proposed to preprocess wind power generation and interpolate missing wind power generation sub-components.Finally,a complete wind power generation time series was reconstructed.Compared to traditional methods,the proposed ICEEMDAN-GAIN combination interpolation model has a higher interpolation accuracy and can effectively reduce the error impact caused by wind power generation sequence fluctuations.