期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Graph Based Two-Phase Procedure for Phasor Data Concentrator Planning in Wide Area Measurement System of Smart Grid
1
作者 Ma Hailong Duan Tong +2 位作者 Yi Peng Jiang Yiming Zhang Jin 《China Communications》 2025年第11期291-304,共14页
The phasor data concentrator placement(PDCP)in wide area measurement systems(WAMS)is an optimization problem in the communication network planning for power grid.Instead of using the traditional integer linear program... The phasor data concentrator placement(PDCP)in wide area measurement systems(WAMS)is an optimization problem in the communication network planning for power grid.Instead of using the traditional integer linear programming(ILP)based modeling and solution schemes that ignore the graph-related features of WAMS,in this work,the PDCP problem is solved through a heuristic graphbased two-phase procedure(TPP):topology partitioning,and phasor data concentrator(PDC)provisioning.Based on the existing minimum k-section algorithms in graph theory,the k-base topology partitioning algorithm is proposed.To improve the performance,the“center-node-last”pre-partitioning algorithm is proposed to give an initial partition before the k-base partitioning algorithm is applied.Then,the PDC provisioning algorithm is proposed to locate PDCs into the decomposed sub-graphs.The proposed TPP was evaluated on five different IEEE benchmark test power systems and the achieved overall communication performance compared to the ILP based schemes show the validity and efficiency of the proposed method. 展开更多
关键词 industrial Internet minimum k-section phasor data concentrator placement phasor measurement unit smart grid topology partitioning wide area measurement system
在线阅读 下载PDF
PMU based adaptive zone settings of distance relays for protection of multi-terminal transmission lines 被引量:5
2
作者 Balimidi Mallikarjuna Pudi Shanmukesh +2 位作者 Dwivedi Anmol Maddikara Jaya Bharata Reddy Dusmanta Kumar Mohanta 《Protection and Control of Modern Power Systems》 2018年第1期136-150,共15页
This paper proposes Phasor Measurement Unit(PMU)based adaptive zone settings of distance relays(PAZSD)methodology for protection of multi-terminal transmission lines(MTL).The PAZSD methodology employs current coeffici... This paper proposes Phasor Measurement Unit(PMU)based adaptive zone settings of distance relays(PAZSD)methodology for protection of multi-terminal transmission lines(MTL).The PAZSD methodology employs current coefficients to adjust the zone settings of the relays during infeed situation.These coefficients are calculated in phasor data concentrator(PDC)at system protection center(SPC)using the current phasors obtained from PMUs.The functioning of the distance relays during infeed condition with and without the proposed methodology has been illustrated through a four-bus model implemented in PSCAD/EMTDC environment.Further,the performance of the proposed methodology has been validated in real-time,on a laboratory prototype of Extra High Voltage multi-terminal transmission lines(EHV MTL).The phasors are estimated in PMUs using NI cRIO-9063 chassis embedded with data acquisition sensors in conjunction with LabVIEW software.The simulation and hardware results prove the efficacy of the proposed methodology in enhancing the performance and reliability of conventional distance protection system in real-time EHV MTLs. 展开更多
关键词 Extra high voltage(EHV) Multiterminal transmission line(MTL) phasor measurement unit(PMU) phasor data concentrator(PDC) Current coefficients
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部