DC line protection with high speed and strong robustness against high fault resistance is essential in highvoltage direct current(HVDC)grids.The conventional voltagederivative-based protections for DC lines exhibit th...DC line protection with high speed and strong robustness against high fault resistance is essential in highvoltage direct current(HVDC)grids.The conventional voltagederivative-based protections for DC lines exhibit the problem of low reliability on the occurrence of high-impedance faults.In this paper,fault traveling waves at the fault point and at the line side of the DC reactor are first analyzed using phasemodal transformation.Based on the theoretical analysis of the modal fault-component voltages at the line side of the DC reactor,a novel hybrid protection scheme utilizing the single-ended rate of change of voltage(ROCOV)and waveform similarity coefficient is proposed.It utilizes the hybrid ROCOV criterion and waveform similarity coefficient to identify the faulted line and the amplitudes of the 0-and 1-mode fault-component voltages to identify fault type,and the polarities of the 0-and 1-mode fault-component voltages to identify faulted pole.Simulations under various fault conditions verify that the proposed protection scheme can achieve fast and reliable identification of faulted line,fault type,and faulted pole in 1 ms,and effectively improve the reliability against high-impedance faults up to 1200.展开更多
基金supported by the National Key Research and Development Program of China under Grant 2016YFB0900900.
文摘DC line protection with high speed and strong robustness against high fault resistance is essential in highvoltage direct current(HVDC)grids.The conventional voltagederivative-based protections for DC lines exhibit the problem of low reliability on the occurrence of high-impedance faults.In this paper,fault traveling waves at the fault point and at the line side of the DC reactor are first analyzed using phasemodal transformation.Based on the theoretical analysis of the modal fault-component voltages at the line side of the DC reactor,a novel hybrid protection scheme utilizing the single-ended rate of change of voltage(ROCOV)and waveform similarity coefficient is proposed.It utilizes the hybrid ROCOV criterion and waveform similarity coefficient to identify the faulted line and the amplitudes of the 0-and 1-mode fault-component voltages to identify fault type,and the polarities of the 0-and 1-mode fault-component voltages to identify faulted pole.Simulations under various fault conditions verify that the proposed protection scheme can achieve fast and reliable identification of faulted line,fault type,and faulted pole in 1 ms,and effectively improve the reliability against high-impedance faults up to 1200.