Active damped LCL-filter-based inverters have been widely used for grid-connected distributed generation(DG) systems. In weak grids, however, the phase-locked loop(PLL) dynamics may detrimentally affect the stability ...Active damped LCL-filter-based inverters have been widely used for grid-connected distributed generation(DG) systems. In weak grids, however, the phase-locked loop(PLL) dynamics may detrimentally affect the stability of grid-connected inverters due to interaction between the PLL and the controller. In order to solve the problem, the impact of PLL dynamics on small-signal stability is investigated for the active damped LCL-filtered grid-connected inverters with capacitor voltage feedback. The system closed-loop transfer function is established based on the Norton equivalent model by taking the PLL dynamics into account. Using an established model, the system stability boundary is identified from the viewpoint of PLL bandwidth and current regulator gain. The accuracy of the ranges of stability for the PLL bandwidth and current regulator gain is verified by both simulation and experimental results.展开更多
When the power grid suffers from grid faults that cause phase disturbances,the grid-connected converter becomes destabilized by the interaction between the phase-locked loop(PLL)and the control loop.In this paper,the ...When the power grid suffers from grid faults that cause phase disturbances,the grid-connected converter becomes destabilized by the interaction between the phase-locked loop(PLL)and the control loop.In this paper,the stability of the PLL affected by the control loop under transient grid faults is studied.First,the equivalent model of the PLL under the influence of the control loop is established.Then,different response processes of PLLs under the ground fault with various control parameters are qualitatively analyzed.Furthermore,a small-signal model is proposed to assess the stability of the PLL under different control loop parameters.The system poles can be calculated to show the physical origin of the instability.Finally,simulations of a three-phase 21-level modular multilevel converter(MMC)built in PSCAD and a down-scale experiment is performed to verify the parameter influence of the control loop on the PLL.展开更多
Frequency support capability for the grid-connected converter(GCC)is one of the basic safeguards for the stability of renewables-dominated power systems.In this paper,analogous to the motion equation of a synchronous ...Frequency support capability for the grid-connected converter(GCC)is one of the basic safeguards for the stability of renewables-dominated power systems.In this paper,analogous to the motion equation of a synchronous generator(SG),an inertial phase-locked loop(iPLL)is proposed for GCC to achieve fast frequency support.The iPLL introduces the inertial and damping loops into the classic PLL structure to emulate the natural frequency regulation characteristics of a SG.Compared with the existing methods,the iPLL has a faster frequency response and is simpler in design and implementation.Finally,the proposed iPLL method is validated by experiments.Index Terms-Frequency support,grid-connected converter,inertial phase-locked loop(iPLL),synchronous generation(SG).展开更多
基金supported by Science Foundation for Distinguished Young Scholars of Hebei Province(No.E2016203133)Hundred Excellent Innovation Talents Support Program of Hebei Province(No.SLRC2017059)
文摘Active damped LCL-filter-based inverters have been widely used for grid-connected distributed generation(DG) systems. In weak grids, however, the phase-locked loop(PLL) dynamics may detrimentally affect the stability of grid-connected inverters due to interaction between the PLL and the controller. In order to solve the problem, the impact of PLL dynamics on small-signal stability is investigated for the active damped LCL-filtered grid-connected inverters with capacitor voltage feedback. The system closed-loop transfer function is established based on the Norton equivalent model by taking the PLL dynamics into account. Using an established model, the system stability boundary is identified from the viewpoint of PLL bandwidth and current regulator gain. The accuracy of the ranges of stability for the PLL bandwidth and current regulator gain is verified by both simulation and experimental results.
基金This work was supported by the National Natural Science Foundation of China(51877159,51637007,U1866601).
文摘When the power grid suffers from grid faults that cause phase disturbances,the grid-connected converter becomes destabilized by the interaction between the phase-locked loop(PLL)and the control loop.In this paper,the stability of the PLL affected by the control loop under transient grid faults is studied.First,the equivalent model of the PLL under the influence of the control loop is established.Then,different response processes of PLLs under the ground fault with various control parameters are qualitatively analyzed.Furthermore,a small-signal model is proposed to assess the stability of the PLL under different control loop parameters.The system poles can be calculated to show the physical origin of the instability.Finally,simulations of a three-phase 21-level modular multilevel converter(MMC)built in PSCAD and a down-scale experiment is performed to verify the parameter influence of the control loop on the PLL.
基金supported in part by the National Natural Science Foundation of China under Grant 52277180in part by the Delta Power Electronics Science and Education Development Program of Delta Group under Grant DREG2021005。
文摘Frequency support capability for the grid-connected converter(GCC)is one of the basic safeguards for the stability of renewables-dominated power systems.In this paper,analogous to the motion equation of a synchronous generator(SG),an inertial phase-locked loop(iPLL)is proposed for GCC to achieve fast frequency support.The iPLL introduces the inertial and damping loops into the classic PLL structure to emulate the natural frequency regulation characteristics of a SG.Compared with the existing methods,the iPLL has a faster frequency response and is simpler in design and implementation.Finally,the proposed iPLL method is validated by experiments.Index Terms-Frequency support,grid-connected converter,inertial phase-locked loop(iPLL),synchronous generation(SG).