A sapphire fibre thermal probe with Cr^3+ ion-doped end is developed by using the laser heated pedestal growth method. The fluorescence thermal probe offers advantages of compact structure, high performance and abili...A sapphire fibre thermal probe with Cr^3+ ion-doped end is developed by using the laser heated pedestal growth method. The fluorescence thermal probe offers advantages of compact structure, high performance and ability to withstand high temperature in a detection range from room temperature to 450℃. Based on the fast Fourier transform (FFT), the fluorescence lifetime is obtained from the tangent function of phase angle of the non-zeroth terms in the FFT result. This method has advantages such as quick calculation, high accuracy and immunity to the background noise. This FFT method is compared with other traditional fitting methods, indicating that the standard deviation of the FFT method is about half of that of the Prony method and about 1/6 of that of the log-fit method. And the FFT method is immune to the background noise involved in a signal. So, the FFT method is an excellent way of processing signals. In addition, a phase-lock amplifier can effectively suppress the noise.展开更多
Sensorless control of switched reluctance motors(SRMs) often requires a hybrid mode combining low-speed pulse injection methods and high-speed model-based estimation.However,pulse injection causes unwanted audible noi...Sensorless control of switched reluctance motors(SRMs) often requires a hybrid mode combining low-speed pulse injection methods and high-speed model-based estimation.However,pulse injection causes unwanted audible noises and torque ripples.This article proposes an enhanced model-based sensorless approach to extend downwards the speed range in which sensorless control can work without injection.An inertial phase-locked loop (IPLL) based on a stator flux observer is introduced for position estimation.Compared to the conventional phase-locked loop scheme,the IPLL offers a more robust disturbance rejection capability and thus reduces the flux model errors at lower speeds.Experimental results substantiate the feasibility of the extended low-speed operation using the model-based sensorless control approach.展开更多
Raman lasers are essential in atomic physics,and the development of portable devices has posed requirements for time-division multiplexing of Raman lasers.We demonstrate an innovative gigahertz frequency hopping appro...Raman lasers are essential in atomic physics,and the development of portable devices has posed requirements for time-division multiplexing of Raman lasers.We demonstrate an innovative gigahertz frequency hopping approach of a slave Raman laser within an optical phase-locked loop(OPLL),which finds practical application in an atomic gravimeter,where the OPLL frequently switches between near-resonance lasers and significantly detuned Raman lasers.The method merges the advantages of rapid and extensive frequency hopping with the OPLL’s inherent low phase noise,and exhibits a versatile range of applications in compact laser systems,promising advancements in portable instruments.展开更多
In this paper,a scheme of commonly-resonated extended interaction circuit system based on high order TMn,mode is proposed to lock the phases of two extended interaction oscillators(EIOs)for generating high power at G-...In this paper,a scheme of commonly-resonated extended interaction circuit system based on high order TMn,mode is proposed to lock the phases of two extended interaction oscillators(EIOs)for generating high power at G-band.Two separate EIOs are coupled through a specific single-gap coupling field supported by a designed gap waveguide with length Lg,which form the phase-locked EIOs based on the commonly-resonated system.As a whole system,the system has been focused on with mode analysis based on different single-gap coupling fields,mode hopping,which present the variation of phase difference between the two-beam-wave interactions when changing Lg.To demonstrate the effectiveness of the proposed circuit system in producing the phase locking,we conducted particle-in-cell(PIC)simulations to show that the interesting mode hopping occurs with the phase difference of O and r between the output signals from two output ports,corresponding to the excitation of the TMn mode with different n.Simulation results show that 1)the oscillator can deliver two times of the output power obtained from one single oscillator at 220 GHz,2)the two EIOs can still deliver output signals with phase difference of O and when the currents of the two beams are different or the fabrication errors of the two EIO cavities are taken into account.The proposed scheme is promising in extending to phase locking between multiple EIOs,and generating higher power at millimeter-wave and higher frequencies.展开更多
As space technology advances,thermal control systems must effectively collect and dissipate heat from distributed,multi-source environments.Loop heat pipe is a highly reliable two-phase heat transfer component,but it ...As space technology advances,thermal control systems must effectively collect and dissipate heat from distributed,multi-source environments.Loop heat pipe is a highly reliable two-phase heat transfer component,but it has several limitations when addressing multi-source heat dissipation.Inspired by the transport and heat dissipation system of plants,large trees achieve stable and efficient liquid supply under the influence of two driving forces:capillary force during transpiration in the leaves(pull)and root pressure generated by osmotic pressure in the roots(push).The root pressure provides an effective liquid supply with a driving force exceeding 2 MPa,far greater than the driving force in conventional capillary-pumped two-phase loops.Research has shown that osmotic heat pipes offer a powerful driving force,and combining osmotic pressure with capillary force has significant advantages.Therefore,this paper designs a multi-evaporator,dual-drive two-phase loop,using both osmotic pressure and capillary force to solve the multi-source heat dissipation challenge.First,a transmembrane water flux model for the osmotic pressure-driven device was established to predict the maximum heat transfer capacity of the dual-drive two-phase loop.Then,an experimental setup for a multi-evaporator“osmotic pressure+capillary force”dual-drive two-phase loop was constructed,capable of transferring at least 235 W of power under a reverse gravity condition of 20 m.The study also analyzed the effects of reverse gravity height,heat load distribution among the three evaporators,startup sequence,and varying branch resistances on the performance of the dual-drive two-phase loop.展开更多
With the development of space-based remote sensing and deep space exploration technology,higher standards for temperature stability and uniformity of payloads have been proposed to spacecraft thermal control systems.A...With the development of space-based remote sensing and deep space exploration technology,higher standards for temperature stability and uniformity of payloads have been proposed to spacecraft thermal control systems.As an efficient two-phase heat transfer device with active temperature control capabilities,the loop heat pipe(LHP)can be widely applied in spacecraft thermal control systems to achieve reliable temperature control under various operating modes and complex space thermal environments.This paper analyzes the fundamental theories of thermal switch-controlled,reservoir temperature-controlled,and bypass valve-controlled LHPs.The focus is on the theories and methods of achieving high-precision and high-reliability temperature control via active reservoir temperature control.Novel control techniques in recent years,such as non-condensable gas(NCG)control with a temperature stability of 0.01℃ ,are also briefly introduced as promising approaches to improve LHP performance.The on-orbit performance and characteristics of various LHP temperature control methods are provided and ranked in terms of control precision,energy consumption,complexity,and weight.Thermoelectric cooler(TEC)/electrical heater,as the foundation of reservoir temperature control,can achieve a temperature stability of in space applications under±0.2℃ a wide range of heat load.Microgravity model,control strategy,and operating mode conversion are three optimization directions that would hopefully further expand the application scenario of reservoir temperature control.Specific design principles and challenges for corresponding directions are summarized as guidance for researchers.展开更多
BACKGROUND In the treatment of rectal cancer,a temporary loop ileostomy(TLI)is created after low anterior resection to protect bowel function in the postoperative period.Dehydration and kidney failure are significant ...BACKGROUND In the treatment of rectal cancer,a temporary loop ileostomy(TLI)is created after low anterior resection to protect bowel function in the postoperative period.Dehydration and kidney failure are significant potential complications in loop ileostomies.Compared to late closure(3-6 months),early closure(10-14 days)of the TLI may facilitate faster patient recovery and shorter hospital stays.AIM To compare early and late closure of TLIs and demonstrate that early stoma closure can be performed without increasing morbidity.METHODS This study included patients who underwent TLI for rectal cancer,with data collected prospectively between June 2016 and October 2024 and analyzed retrospectively.Patients whose stomas were closed in the late period(3-6 months)between June 2016 and October 2022(group A)were compared with those who underwent early closure(10-14 days)between October 2022 and 2024(group B),with the primary outcome being complication rate and the secondary outcome being quality of life.RESULTS A total of 270 TLIs were created(70.9%).Of these,120(44.4%)were closed in the late period(group A),and 150(55.6%)were closed in the early period(group B).There was no statistically significant difference between group A and group B in terms of demographic and clinicopathological characteristics(P>0.05).Perioperative(anesthesia management,operative time,blood loss,surgical technique)and postoperative findings(anastomotic leak,infection)were similar between the two groups and were not statistically significant(P>0.05).There were no statistically significant differences in complication rates as the primary outcome between the two groups.Quality of life as a secondary outcome was significantly higher in the early closure group(P<0.05).CONCLUSION No statistically significant difference was found between early and late loop ileostomy closure in terms of perioperative and postoperative morbidity.Early closure accelerated patients’psychological and social recovery.展开更多
Most synchrotron light storage rings are equipped with a higher harmonic cavity(HHC)and are currently predominantly used to increase beam life.With the enhancement of the beam current intensity,it is necessary to cons...Most synchrotron light storage rings are equipped with a higher harmonic cavity(HHC)and are currently predominantly used to increase beam life.With the enhancement of the beam current intensity,it is necessary to consider instability problems that may be caused by heavy beam loading effects.In this study,we incorporated a HHC into the small-signal Pedersen mathematical model and used system signal analysis to investigate the mode-zero Robinson instability driven by the passive superconducting harmonic cavity and active superconducting harmonic cavity fundamental modes.To further study and alleviate this instability,we introduced direct radio-frequency feedback,an automatic voltage control loop,and a phase-lock loop into the model,discussed the impact of the feedback loop parameter settings on the stability margin,and provided suggestions for parameter settings.展开更多
Vibration-induced bias deviation,which is generated by intensity fluctuations and additional phase differences,is one of the vital errors for fiber optic gyroscopes(FOGs)operating in vibration environment and has seve...Vibration-induced bias deviation,which is generated by intensity fluctuations and additional phase differences,is one of the vital errors for fiber optic gyroscopes(FOGs)operating in vibration environment and has severely restricted the applications of high-precision FOGs.The conventional methods for suppressing vibration-induced errors mostly concentrate on reinforcing the mechanical structure and optical path as well as the compensation under some specific operation parameters,which have very limited effects for high-precision FOGs maintaining performances under vibration.In this work,a technique of suppressing the vibration-induced bias deviation through removing the part related to the varying gain from the rotation-rate output is put forward.Particularly,the loop gain is extracted out by adding a gain-monitoring wave.By demodulating the loop gain and the rotation rate simultaneously under distinct frequencies and investigating their quantitative relationship,the vibrationinduced bias error is compensated without limiting the operating parameters or environments,like the applied modulation depth.The experimental results show that the proposed method has achieved the reduction of bias error from about 0.149°/h to0.014°/h during the random vibration with frequencies from20 Hz to 2000 Hz.This technique provides a feasible route for enhancing the performances of high-precision FOGs heading towards high environmental adaptability.展开更多
This paper presents a compact ultra-low-power phase-locked loop (PLL) based binary phase-shift keying(BPSK)demodulator. The loop-filter-less(LPF-less) PLL is proposed to make phase of PLL output carrier signal track t...This paper presents a compact ultra-low-power phase-locked loop (PLL) based binary phase-shift keying(BPSK)demodulator. The loop-filter-less(LPF-less) PLL is proposed to make phase of PLL output carrier signal track the phase of BPSK signal in real time. Thus, the maximum date rate can be significantly extended to the half of the carrier frequency(f_(carrier)) with a very compact size compared to prior PLL-based BPSK demodulators. Furthermore, eliminating all the static power in our LPF-less PLL, the energy efficiency is obviously improved. Fabricated in a 40-nm CMOS process, our prototype occupies 0.0012-mm^(2)core active area, and achieves the maximum data rate of 6.78 Mb/s (f_(carrier)/2) at f_(carrier)of 13.56 MHz. The power consumption and energy efficiency is 4.47 μW and 0.66 pJ/bit at 6.78-Mb/s data rate, respectively.展开更多
In-loop filters have been comprehensively explored during the development of video coding standards due to their remarkable noise-reduction capabilities.In the early stage of video coding,in-loop filters,such as the d...In-loop filters have been comprehensively explored during the development of video coding standards due to their remarkable noise-reduction capabilities.In the early stage of video coding,in-loop filters,such as the deblocking filter,sample adaptive offset,and adaptive loop filter,were performed separately for each component.Recently,cross-component filters have been studied to improve chroma fidelity by exploiting correlations between the luma and chroma channels.This paper introduces the cross-component filters used in the state-ofthe-art video coding standards,including the cross-component adaptive loop filter and cross-component sample adaptive offset.Crosscomponent filters aim to reduce compression artifacts based on the correlation between different components and provide more accurate pixel reconstruction values.We present their origin,development,and status in the current video coding standards.Finally,we conduct discussions on the further evolution of cross-component filters.展开更多
文摘A sapphire fibre thermal probe with Cr^3+ ion-doped end is developed by using the laser heated pedestal growth method. The fluorescence thermal probe offers advantages of compact structure, high performance and ability to withstand high temperature in a detection range from room temperature to 450℃. Based on the fast Fourier transform (FFT), the fluorescence lifetime is obtained from the tangent function of phase angle of the non-zeroth terms in the FFT result. This method has advantages such as quick calculation, high accuracy and immunity to the background noise. This FFT method is compared with other traditional fitting methods, indicating that the standard deviation of the FFT method is about half of that of the Prony method and about 1/6 of that of the log-fit method. And the FFT method is immune to the background noise involved in a signal. So, the FFT method is an excellent way of processing signals. In addition, a phase-lock amplifier can effectively suppress the noise.
基金supported in part by the National Natural Science Foundation of China 52307069in part by 2024 Tertiary Education Scientific Research Project of Guangzhou Municipal Education Bureau under Grant2024312176in part by the Project of Hetao Shenzhen-Hong Kong Science and Technology Innovation Cooperation Zone under Grant HZQB-KCZYB-2020083。
文摘Sensorless control of switched reluctance motors(SRMs) often requires a hybrid mode combining low-speed pulse injection methods and high-speed model-based estimation.However,pulse injection causes unwanted audible noises and torque ripples.This article proposes an enhanced model-based sensorless approach to extend downwards the speed range in which sensorless control can work without injection.An inertial phase-locked loop (IPLL) based on a stator flux observer is introduced for position estimation.Compared to the conventional phase-locked loop scheme,the IPLL offers a more robust disturbance rejection capability and thus reduces the flux model errors at lower speeds.Experimental results substantiate the feasibility of the extended low-speed operation using the model-based sensorless control approach.
基金Project supported by the National Key Research and Development Program of China(Grant Nos.2021YFA0718300 and 2021YFA1400900)the National Natural Science Foundation of China(Grant Nos.11920101004,11934002,and 92365208)+1 种基金Science and Technology Major Project of Shanxi(Grant No.202101030201022)Space Application System of China Manned Space Program.
文摘Raman lasers are essential in atomic physics,and the development of portable devices has posed requirements for time-division multiplexing of Raman lasers.We demonstrate an innovative gigahertz frequency hopping approach of a slave Raman laser within an optical phase-locked loop(OPLL),which finds practical application in an atomic gravimeter,where the OPLL frequently switches between near-resonance lasers and significantly detuned Raman lasers.The method merges the advantages of rapid and extensive frequency hopping with the OPLL’s inherent low phase noise,and exhibits a versatile range of applications in compact laser systems,promising advancements in portable instruments.
基金Supported in part by the National Natural Science Foundation of China(62401125)the Natural Science Foundation of Sichuan Province(2023NSFSC1376)the Fundamental Research Funds for the Central Universities(ZYGX2024J008)。
文摘In this paper,a scheme of commonly-resonated extended interaction circuit system based on high order TMn,mode is proposed to lock the phases of two extended interaction oscillators(EIOs)for generating high power at G-band.Two separate EIOs are coupled through a specific single-gap coupling field supported by a designed gap waveguide with length Lg,which form the phase-locked EIOs based on the commonly-resonated system.As a whole system,the system has been focused on with mode analysis based on different single-gap coupling fields,mode hopping,which present the variation of phase difference between the two-beam-wave interactions when changing Lg.To demonstrate the effectiveness of the proposed circuit system in producing the phase locking,we conducted particle-in-cell(PIC)simulations to show that the interesting mode hopping occurs with the phase difference of O and r between the output signals from two output ports,corresponding to the excitation of the TMn mode with different n.Simulation results show that 1)the oscillator can deliver two times of the output power obtained from one single oscillator at 220 GHz,2)the two EIOs can still deliver output signals with phase difference of O and when the currents of the two beams are different or the fabrication errors of the two EIO cavities are taken into account.The proposed scheme is promising in extending to phase locking between multiple EIOs,and generating higher power at millimeter-wave and higher frequencies.
基金Science Foundation for Distinguished Young Scholars 2020-JCJQ-ZQ-042 Intelligent and Bionic Spacecraft Thermal Control Technology Inspired by Tree Sap Transport Principle.
文摘As space technology advances,thermal control systems must effectively collect and dissipate heat from distributed,multi-source environments.Loop heat pipe is a highly reliable two-phase heat transfer component,but it has several limitations when addressing multi-source heat dissipation.Inspired by the transport and heat dissipation system of plants,large trees achieve stable and efficient liquid supply under the influence of two driving forces:capillary force during transpiration in the leaves(pull)and root pressure generated by osmotic pressure in the roots(push).The root pressure provides an effective liquid supply with a driving force exceeding 2 MPa,far greater than the driving force in conventional capillary-pumped two-phase loops.Research has shown that osmotic heat pipes offer a powerful driving force,and combining osmotic pressure with capillary force has significant advantages.Therefore,this paper designs a multi-evaporator,dual-drive two-phase loop,using both osmotic pressure and capillary force to solve the multi-source heat dissipation challenge.First,a transmembrane water flux model for the osmotic pressure-driven device was established to predict the maximum heat transfer capacity of the dual-drive two-phase loop.Then,an experimental setup for a multi-evaporator“osmotic pressure+capillary force”dual-drive two-phase loop was constructed,capable of transferring at least 235 W of power under a reverse gravity condition of 20 m.The study also analyzed the effects of reverse gravity height,heat load distribution among the three evaporators,startup sequence,and varying branch resistances on the performance of the dual-drive two-phase loop.
基金funded by National Outstanding Youth Foundation of China,grant number 2020-JCJQ-ZQ-042.
文摘With the development of space-based remote sensing and deep space exploration technology,higher standards for temperature stability and uniformity of payloads have been proposed to spacecraft thermal control systems.As an efficient two-phase heat transfer device with active temperature control capabilities,the loop heat pipe(LHP)can be widely applied in spacecraft thermal control systems to achieve reliable temperature control under various operating modes and complex space thermal environments.This paper analyzes the fundamental theories of thermal switch-controlled,reservoir temperature-controlled,and bypass valve-controlled LHPs.The focus is on the theories and methods of achieving high-precision and high-reliability temperature control via active reservoir temperature control.Novel control techniques in recent years,such as non-condensable gas(NCG)control with a temperature stability of 0.01℃ ,are also briefly introduced as promising approaches to improve LHP performance.The on-orbit performance and characteristics of various LHP temperature control methods are provided and ranked in terms of control precision,energy consumption,complexity,and weight.Thermoelectric cooler(TEC)/electrical heater,as the foundation of reservoir temperature control,can achieve a temperature stability of in space applications under±0.2℃ a wide range of heat load.Microgravity model,control strategy,and operating mode conversion are three optimization directions that would hopefully further expand the application scenario of reservoir temperature control.Specific design principles and challenges for corresponding directions are summarized as guidance for researchers.
文摘BACKGROUND In the treatment of rectal cancer,a temporary loop ileostomy(TLI)is created after low anterior resection to protect bowel function in the postoperative period.Dehydration and kidney failure are significant potential complications in loop ileostomies.Compared to late closure(3-6 months),early closure(10-14 days)of the TLI may facilitate faster patient recovery and shorter hospital stays.AIM To compare early and late closure of TLIs and demonstrate that early stoma closure can be performed without increasing morbidity.METHODS This study included patients who underwent TLI for rectal cancer,with data collected prospectively between June 2016 and October 2024 and analyzed retrospectively.Patients whose stomas were closed in the late period(3-6 months)between June 2016 and October 2022(group A)were compared with those who underwent early closure(10-14 days)between October 2022 and 2024(group B),with the primary outcome being complication rate and the secondary outcome being quality of life.RESULTS A total of 270 TLIs were created(70.9%).Of these,120(44.4%)were closed in the late period(group A),and 150(55.6%)were closed in the early period(group B).There was no statistically significant difference between group A and group B in terms of demographic and clinicopathological characteristics(P>0.05).Perioperative(anesthesia management,operative time,blood loss,surgical technique)and postoperative findings(anastomotic leak,infection)were similar between the two groups and were not statistically significant(P>0.05).There were no statistically significant differences in complication rates as the primary outcome between the two groups.Quality of life as a secondary outcome was significantly higher in the early closure group(P<0.05).CONCLUSION No statistically significant difference was found between early and late loop ileostomy closure in terms of perioperative and postoperative morbidity.Early closure accelerated patients’psychological and social recovery.
文摘Most synchrotron light storage rings are equipped with a higher harmonic cavity(HHC)and are currently predominantly used to increase beam life.With the enhancement of the beam current intensity,it is necessary to consider instability problems that may be caused by heavy beam loading effects.In this study,we incorporated a HHC into the small-signal Pedersen mathematical model and used system signal analysis to investigate the mode-zero Robinson instability driven by the passive superconducting harmonic cavity and active superconducting harmonic cavity fundamental modes.To further study and alleviate this instability,we introduced direct radio-frequency feedback,an automatic voltage control loop,and a phase-lock loop into the model,discussed the impact of the feedback loop parameter settings on the stability margin,and provided suggestions for parameter settings.
基金Fundamental Research Funds for the Central Universities(YWF-23-L-1225)National Natural Science Foundation of China(62201025)Chinese Aeronautical Establishment(2022Z037051001)。
文摘Vibration-induced bias deviation,which is generated by intensity fluctuations and additional phase differences,is one of the vital errors for fiber optic gyroscopes(FOGs)operating in vibration environment and has severely restricted the applications of high-precision FOGs.The conventional methods for suppressing vibration-induced errors mostly concentrate on reinforcing the mechanical structure and optical path as well as the compensation under some specific operation parameters,which have very limited effects for high-precision FOGs maintaining performances under vibration.In this work,a technique of suppressing the vibration-induced bias deviation through removing the part related to the varying gain from the rotation-rate output is put forward.Particularly,the loop gain is extracted out by adding a gain-monitoring wave.By demodulating the loop gain and the rotation rate simultaneously under distinct frequencies and investigating their quantitative relationship,the vibrationinduced bias error is compensated without limiting the operating parameters or environments,like the applied modulation depth.The experimental results show that the proposed method has achieved the reduction of bias error from about 0.149°/h to0.014°/h during the random vibration with frequencies from20 Hz to 2000 Hz.This technique provides a feasible route for enhancing the performances of high-precision FOGs heading towards high environmental adaptability.
基金supported by the National Natural Science Foundation of China under grant 62222409 and 62174153by Key Research Program of Frontier Sciences, CAS, under grant ZDBS-LY-JSC008。
文摘This paper presents a compact ultra-low-power phase-locked loop (PLL) based binary phase-shift keying(BPSK)demodulator. The loop-filter-less(LPF-less) PLL is proposed to make phase of PLL output carrier signal track the phase of BPSK signal in real time. Thus, the maximum date rate can be significantly extended to the half of the carrier frequency(f_(carrier)) with a very compact size compared to prior PLL-based BPSK demodulators. Furthermore, eliminating all the static power in our LPF-less PLL, the energy efficiency is obviously improved. Fabricated in a 40-nm CMOS process, our prototype occupies 0.0012-mm^(2)core active area, and achieves the maximum data rate of 6.78 Mb/s (f_(carrier)/2) at f_(carrier)of 13.56 MHz. The power consumption and energy efficiency is 4.47 μW and 0.66 pJ/bit at 6.78-Mb/s data rate, respectively.
基金supported in part by National Science Foundation of China under Grant No.62031013PCL-CMCC Foundation for Science and Innovation under Grant No.2024ZY1C0040+1 种基金New Cornerstone Science Foundation for the Xplorer PrizeHigh performance Computing Platform of Peking University。
文摘In-loop filters have been comprehensively explored during the development of video coding standards due to their remarkable noise-reduction capabilities.In the early stage of video coding,in-loop filters,such as the deblocking filter,sample adaptive offset,and adaptive loop filter,were performed separately for each component.Recently,cross-component filters have been studied to improve chroma fidelity by exploiting correlations between the luma and chroma channels.This paper introduces the cross-component filters used in the state-ofthe-art video coding standards,including the cross-component adaptive loop filter and cross-component sample adaptive offset.Crosscomponent filters aim to reduce compression artifacts based on the correlation between different components and provide more accurate pixel reconstruction values.We present their origin,development,and status in the current video coding standards.Finally,we conduct discussions on the further evolution of cross-component filters.