期刊文献+
共找到821篇文章
< 1 2 42 >
每页显示 20 50 100
Sparse-view phase-contrast and attenuation-based CT reconstruction utilizing model-driven deep learning
1
作者 Xia-Yu Tao Qi-Si Lin +3 位作者 Zhao Wu Yong Guan Yang-Chao Tian Gang Liu 《Nuclear Science and Techniques》 2025年第4期59-71,共13页
Grating-based X-ray phase-contrast imaging enhances the contrast of imaged objects,particularly soft tissues.However,the radiation dose in computed tomography(CT)is generally excessive owing to the complex collection ... Grating-based X-ray phase-contrast imaging enhances the contrast of imaged objects,particularly soft tissues.However,the radiation dose in computed tomography(CT)is generally excessive owing to the complex collection scheme.Sparse-view CT collection reduces the radiation dose,but with reduced resolution and reconstructed artifacts particularly in analytical reconstruction methods.Recently,deep learning has been employed in sparse-view CT reconstruction and achieved stateof-the-art results.Nevertheless,its low generalization performance and requirement for abundant training datasets have hindered the practical application of deep learning in phase-contrast CT.In this study,a CT model was used to generate a substantial number of simulated training datasets,thereby circumventing the need for experimental datasets.By training a network with simulated training datasets,the proposed method achieves high generalization performance in attenuationbased CT and phase-contrast CT,despite the lack of sufficient experimental datasets.In experiments utilizing only half of the CT data,our proposed method obtained an image quality comparable to that of the filtered back-projection algorithm with full-view projection.The proposed method simultaneously addresses two challenges in phase-contrast three-dimensional imaging,namely the lack of experimental datasets and the high exposure dose,through model-driven deep learning.This method significantly accelerates the practical application of phase-contrast CT. 展开更多
关键词 Sparse-view CT phase-contrast CT Attenuation-based CT Deep learning network Frequency loss function
在线阅读 下载PDF
Cerebral blood flow volume measurements of the carotid artery and ipsilateral branches using two-dimensional phase-contrast magnetic resonance angiography
2
作者 Gang Guo Yonggui Yang Weiqun Yang 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第30期2367-2371,共5页
The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC ... The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries. 展开更多
关键词 two-dimensional phase-contrast magnetic resonance angiography blood flow three-dimensional time-of-flight phase-contrast magnetic resonance angiography internal carotid artery common carotid artery external carotid artery velocity encoding
在线阅读 下载PDF
Visibility in differential phase-contrast imaging with partial coherence source 被引量:3
3
作者 刘鑫 郭金川 +1 位作者 彭翔 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第6期1632-1636,共5页
This paper gives theoretical analysis of visibility of fringes, which is influenced by distances, temporal and spatial coherence of source, in hard x-ray differential phase-contrast imaging with microfocus x-ray sourc... This paper gives theoretical analysis of visibility of fringes, which is influenced by distances, temporal and spatial coherence of source, in hard x-ray differential phase-contrast imaging with microfocus x-ray source. According to the character of longitudinal periodicity of the interferogram, the setup is insensitive to mechanical drift and vibrations. The effect of temporal coherence of x-ray source is investigated and its related bandwidth is derived. Based on the theory of partially coherent light, it shows that the requirement for the spatial coherence of x-ray source is not strict and can be met by the general microfocus x-ray tube for x-ray differential phase-contrast imaging. 展开更多
关键词 VISIBILITY differential phase-contrast interference fringes phase grating
原文传递
Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts 被引量:1
4
作者 冀东江 渠刚荣 +3 位作者 胡春红 刘宝东 简建波 郭晓坤 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第6期93-100,共8页
In-line phase-contrast computed tomography(IL-PC-CT) imaging is a new physical and biochemical imaging method.IL-PC-CT has advantages compared to absorption CT when imaging soft tissues. In practical applications, r... In-line phase-contrast computed tomography(IL-PC-CT) imaging is a new physical and biochemical imaging method.IL-PC-CT has advantages compared to absorption CT when imaging soft tissues. In practical applications, ring artifacts which will reduce the image quality are commonly encountered in IL-PC-CT, and numerous correction methods exist to either pre-process the sinogram or post-process the reconstructed image. In this study, we develop an IL-PC-CT reconstruction method based on anisotropic total variation(TV) minimization. Using this method, the ring artifacts are corrected during the reconstruction process. This method is compared with two methods: a sinogram preprocessing correction technique based on wavelet-FFT filter and a reconstruction method based on isotropic TV. The correction results show that the proposed method can reduce visible ring artifacts while preserving the liver section details for real liver section synchrotron data. 展开更多
关键词 SART anisotropic TV in-line phase-contrast
原文传递
Quantitative assessment of physiological cerebrospinal fluid flow in the cervical spinal canal with 3.0T phase-contrast cine MRI
5
作者 Hua Shang Huaijun +3 位作者 Liu Leka Yan Jianming Lei Caixia Cui Hui Li 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第18期1392-1397,共6页
A total of 50 healthy volunteers aged between 18 and 54 years underwent phase-contrast cine MR to assess cerebrospinal fluid flow characteristics in different regions of the vertebral canal. The results revealed that ... A total of 50 healthy volunteers aged between 18 and 54 years underwent phase-contrast cine MR to assess cerebrospinal fluid flow characteristics in different regions of the vertebral canal. The results revealed that the cerebrospinal fluid peak flow velocity and peak flow rate in the systolic phase were significantly greater than those in the diastolic phase at the same level in the subarachnoid space of the cervical spinal canal. The ventral peak flow velocity and peak flow rate were significantly greater than the post-lateral peak flow velocity and flow rate, while there were no differences between left and right post-lateral subarachnoid peak velocity and flow rate. Moreover, there were no significant differences in peak flow velocity and peak flow rate between the systolic and diastolic phases, ventral, right post-lateral or left post-lateral peak flow velocity and peak flow rate at the same level in the subarachnoid space of the cervical spinal canal among different age groups (18 24, 25 34, 35-44, ≥45 years). 展开更多
关键词 magnetic resonance imaging phase-contrast cerebrospinal fluid vertebral canal subarachnoidspace flow velocity neural regeneration
在线阅读 下载PDF
Optimal velocity encoding during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography
6
作者 Gang Guo Yonggui Yang Weiqun Yang 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第23期1796-1800,共5页
This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-con... This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-contrast magnetic resonance angiography slice was applied perpendicular to the internal carotid artery and the vertebral artery at C2 level. For each subject, the velocity encoding was set from 30 to 90 cm/s with an interval of 10 cm/s for a total of seven settings. Various velocity encodings greatly affected blood flow volume, maximal blood flow velocity and mean blood flow velocity in the internal carotid artery, but did not significantly affect vertebral arteries and jugular veins. When velocity encoding was 60-80 cm/s, the inflow blood volume was 655 _+ 118 mL/min, and the outflow volume was 506 _+ 186 mL/min. The ratio of outflow/inflow was steady at 0.78-0.83, and there was no aliasing in any of the images. These findings suggest that velocity encodings of 60 80 cm/s should be selected during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography. 展开更多
关键词 cerebral blood flow velocity encoding phase-contrast magnetic resonance imaging
在线阅读 下载PDF
Noise properties of multi-combination information in x-ray grating-based phase-contrast imaging
7
作者 Wali Faiz Ji Li +4 位作者 Kun Gao Zhao Wu Yao-Hu Lei Jian-Heng Huang Pei-Ping Zhu 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第1期329-335,共7页
Grating-based x-ray phase contrast imaging has attracted increasing interest in recent decades as multimodal and laboratory source usable method.Specific efforts have been focused on establishing a new extraction meth... Grating-based x-ray phase contrast imaging has attracted increasing interest in recent decades as multimodal and laboratory source usable method.Specific efforts have been focused on establishing a new extraction method to perform practical applications.In this work,noise properties of multi-combination information of newly established information extraction method,so-called angular signal radiography method,are investigated to provide guidelines for targeted and specific applications.The results show that how multi-combination of images can be used in targeted practical applications to obtain a high-quality image in terms of signal-to-noise ratio.Our conclusions can also hold true for upcoming targeted practical applications such as biomedical imaging,non-destructive imaging,and materials science. 展开更多
关键词 grating-based phase-contrast imaging signal-to-noise ratio REFRACTION SCATTERING
原文传递
Effects of Tube Voltage on Phase-Contrast Imaging for Different Microfocus X-Ray Tubes
8
作者 Jianbao Gui Zhanli Hu +1 位作者 Peter Z. Wu Hairong Zheng 《Engineering(科研)》 2013年第10期590-594,共5页
In the past decade, phase-contrast imaging (PCI) has become a hot research with an increased improvement of the image contrast with respect to conventional absorption radiography. In this paper, effects of tube voltag... In the past decade, phase-contrast imaging (PCI) has become a hot research with an increased improvement of the image contrast with respect to conventional absorption radiography. In this paper, effects of tube voltage (kVp) on propagation-based phase-contrast imaging have been investigated with two types of microfocus x-ray tubes, a conventional sealed x-ray tube with the focal spot size of 13 - 20 μm and an open x-ray tube with minimum focal spot size less than 2 μm. A cooled x-ray CCD detector with the pixel size of 24 μm was used to acquire digital images. Two thin plastic sheets with different thickness were used as radiography phantoms. Two different phenomena were observed for the two x-ray tubes. For the open tube, phase-contrast effect has a slight drop with the increasing of tube voltage, however, it is opposite for the sealed tube. A further investigation indicates that the variation of focal spot size causes the abnormal result for the sealed tube. It also shows that phase-contrast effect is more sensitive to focal spot size than tube voltage. 展开更多
关键词 phase-contrast Imaging EDGE Enhancement X-RAY TUBE VOLTAGE
暂未订购
Application of phase-contrast cine gnetic resonance imaging (MRI) in endoscopic aqueductoplasty
9
作者 郑佳平 《外科研究与新技术》 2011年第3期222-223,共2页
Objective To evaluate the application of phasecontrast cine magnetic resonance imaging (MRI) in endoscopic aqueductoplasty for patients with obstructive hydrocephalus. Methods The clinical diagnosis of hydrocephalus d... Objective To evaluate the application of phasecontrast cine magnetic resonance imaging (MRI) in endoscopic aqueductoplasty for patients with obstructive hydrocephalus. Methods The clinical diagnosis of hydrocephalus due to aqueduct obstruction in 23 patients was confirmed by phase contrast cine MRI examination. 展开更多
关键词 MRI in endoscopic aqueductoplasty Application of phase-contrast cine gnetic resonance imaging
暂未订购
In-line X-ray phase-contrast imaging of murine liver microvasculature ex vivo 被引量:5
10
作者 LI Beilei XU Min +5 位作者 WU Weizhong PENG Guanyun ZHANG Xi PENG Yifeng SHI Hongcheng CHEN Shaoliang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2012年第1期10-14,共5页
Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.V... Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.Visualizing murine liver microvasculature ex vivo with phase-contrast X-ray imaging was performed at Shanghai Synchrotron Radiation Facility.Barium sulfate and physiological saline were used as contrast agents for the blood vessels.Blood vessels of <Φ20μm could be detected by replacing resident blood with physiological saline or barium sulfate.An entire branch of the portal vein (from the main axial portal vein to the ninth generation of branching) could be captured in a single phase-contrast image.It is demonstrated that selective angiography based on phase contrast X-ray imaging,with a physiological material of low Z elements (such as saline) being the contrast agent,is a viable imaging strategy.Further efforts will be focused on using the technique to image tumor angiogenesis. 展开更多
关键词 X射线成像 相衬成像 微血管 体外 小鼠 上海同步辐射装置 肿瘤血管生成 生理盐水
在线阅读 下载PDF
A new method of detecting interferogram in differential phase-contrast imaging system based on special structured x-ray scintillator screen 被引量:6
11
作者 刘鑫 郭金川 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期193-197,共5页
An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and ... An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and difficulty of fabrication by a state of the art technique. On the basis of phase grating diffraction, a detecting model of the scintillator screen was built for analysing the phase and absorption information of objects. According to the analysis, a new method of phase retrievals based on two-images and the optimal structure of screen were presented. 展开更多
关键词 differential phase contrast x-ray scintillator screen phase retrieval
原文传递
Computational Fluid Dynamics and Its Impact on Flow Measurements Using Phase-Contrast MR-Angiography
12
作者 Claus Kiefer Frauke Kellner-Weldon 《Open Journal of Medical Imaging》 2012年第1期23-28,共6页
Rationale and Objectives: Computational fluid dynamic (CFD) simulations are discussed with respect to their potential for quality assurance of flow quantification using commercial software for the evaluation of magnet... Rationale and Objectives: Computational fluid dynamic (CFD) simulations are discussed with respect to their potential for quality assurance of flow quantification using commercial software for the evaluation of magnetic resonance phase contrast angiography (PCA) data. Materials and Methods: Magnetic resonance phase contrast angiography data was evaluated with the Nova software. CFD simulations were performed on that part of the vessel system where the flow behavior was unexpected or non-reliable. The CFD simulations were performed with in-house written software. Results: The numerical CFD calculations demonstrated that under reasonable boundary conditions, defined by the PCA velocity values, the flow behavior within the critical parts of the vessel system can be correctly reproduced. Conclusion: CFD simulations are an important extension to commercial flow quantification tools with regard to quality assurance. 展开更多
关键词 CFD Flow PHASE CONTRAST ANGIOGRAPHY Quality ASSURANCE
暂未订购
Differential diagnosis of arachnoid cyst from subarachnoid space enlargement by phase-contrast cine MRI
13
作者 于群 孔祥泉 刘定西 《Chinese Medical Journal》 SCIE CAS CSCD 2003年第1期116-120,共5页
Objectives To reveal the relationship of brain motion and cerebrospinal fluid (CSF) flow by phase-contrast cine MRI, and to evaluate this technique in differentiating between arachnoid cysts and subarachnoid space en... Objectives To reveal the relationship of brain motion and cerebrospinal fluid (CSF) flow by phase-contrast cine MRI, and to evaluate this technique in differentiating between arachnoid cysts and subarachnoid space enlargement. Methods Using a phase-contrast cine MRI pulse sequence, we measured brain motion and CSF flow during the cardiac cycle in 10 healthy volunteers and 10 patients with MRI-suspected arachnoid cyst or subarachnoid space enlargement. CSF stroke volume curve was illustrated according to flow quantification, and time-signal intensity curve was traced. The two curves were compared. Results This study showed that brain motion was due to the volume difference between arterial and venous blood flow during a cardiac cycle, and thus drives CSF pulsation. Arachnoid cysts and subarachnoid space enlargement carried different curve patterns, demonstrating that phase-contrast MRI and flow quantification can be a useful and reliable technique for non-invasive evaluation of brain motion and CSF flow. Conclusion Arachnoid cysts can be successfully differentiated using phase-contrast cine MRI from subarachnoid space enlargement. 展开更多
关键词 arachnoid cyst subarachnoid space enlargement phase-contrast cine MRI DIAGNOSIS differentiate motion
原文传递
Enhanced quantitative X-ray phase-contrast images using Foucault differential filters
14
作者 Jaeho Choi Young-Sung Park 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第8期44-47,共4页
Several X-ray phase visualization methods are being real- ized for imaging of phase objects, such as biological and polymeric specimens. Grating-based phase-contrast imaging using a source-grating-attached X-ray tube ... Several X-ray phase visualization methods are being real- ized for imaging of phase objects, such as biological and polymeric specimens. Grating-based phase-contrast imaging using a source-grating-attached X-ray tube that provides partially coherent X rays is one of the most successful methods in this field. 展开更多
关键词 real Enhanced quantitative X-ray phase-contrast images using Foucault differential filters FDF
原文传递
Phase-contrast Imaging Simulation Based on a Micro-CT System
15
作者 GUI Jian-bao ZOU Jing +4 位作者 RONG Jun-yan HU Zhan-li ZHANG Qi-yang ZHENG Hai-rong XIA Dan 《Chinese Journal of Biomedical Engineering(English Edition)》 CSCD 2016年第2期87-92,共6页
Propagation-based phase-contrast imaging was simulated based on paraxial Fresnel-Kirchoff diffraction integral and spherical wave illumination. Under a developed micro-CT system parameters, the effects of focal-spot s... Propagation-based phase-contrast imaging was simulated based on paraxial Fresnel-Kirchoff diffraction integral and spherical wave illumination. Under a developed micro-CT system parameters, the effects of focal-spot size and imaging geometry on phase-contrast imaging have been investigated using a 2-mm-thickness polystyrene edge phantom. An equivalent mono-energy was used to substitute the polychromatic spectrum of the micro-focus X-ray source. To consider effects of focal-spot size and detector resolution, the obtained phase-contrast image with an ideal point source was convolved with source intensity distribution and point spread function of detector. Simulations show reasonable influences of the two parameters which are in good agreement with experimental results. 展开更多
关键词 MICRO-CT phase-contrast imaging X-RAY micro-focus source SIMULATION
暂未订购
Quantitative Measurements of Red Blood Cell Indices Using Spectroscopic Differential Phase-Contrast Microscopy
16
作者 Taegyun Moon Andrew Heegeon Yang +5 位作者 Seungri Song Malith Ranathunga Yea-Jin Song Mi-Sook Yang Jaewoo Song Chulmin Joo 《Chemical & Biomedical Imaging》 2023年第8期750-759,共10页
Red blood cell(RBC)indices serve as clinically important parameters for diagnosing various blood-related diseases.Conventional hematology analyzers provide the highly accurate detection of RBC indices but require larg... Red blood cell(RBC)indices serve as clinically important parameters for diagnosing various blood-related diseases.Conventional hematology analyzers provide the highly accurate detection of RBC indices but require large blood volumes(>1 mL),and the results are bulk mean values averaged over a large number of RBCs.Moreover,they do not provide quantitative information related to the morphological and chemical alteration of RBCs at the single-cell level.Recently,quantitative phase imaging(QPI)methods have been introduced as viable detection platforms for RBC indices.However,coherent QPI methods are built on complex optical setups and suffer from coherent speckle noise,which limits their detection accuracy and precision.Here,we present spectroscopic differential phase-contrast(sDPC)microscopy as a platform for measuring RBC indices.sDPC is a computational microscope that produces color-dependent phase images with higher spatial resolution and reduced speckle noise compared to coherent QPIs.Using these spectroscopic phase images and computational algorithms,RBC indices can be extracted with high accuracy.We experimentally demonstrate that sDPC enables the high-accuracy measurement of the mean corpuscular hemoglobin concentration,mean corpuscular volume,mean corpuscular hemoglobin,red cell distribution width,hematocrit,hemoglobin concentration,and RBC count with errors smaller than 7%as compared to a clinical hematology analyzer based on flow cytometry(XN-2000;Sysmex,Kobe,Japan).We further validate the clinical utility of the sDPC method by measuring and comparing the RBC indices of the control and anemic groups against those obtained using the clinical hematology analyzer. 展开更多
关键词 red blood cell indices quantitative phase imaging image-based cytometry incoherent imaging differential phase-contrast microscopy
暂未订购
Optimization of the in-line X-ray phase-contrast imaging setup considering edge-contrast enhancement and spatial resolution 被引量:2
17
作者 贾全杰 陈雨 +1 位作者 黎刚 姜晓明 《Chinese Physics C》 SCIE CAS CSCD 2012年第3期267-274,共8页
Employing the approximation theory based on refraction and the definition of the total pointspread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different... Employing the approximation theory based on refraction and the definition of the total pointspread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different source-to-sample and sample-to-detector distances, which actually means different spatial resolutions of the imaging system. The experiments were carried out with the Beamline 4W1A imaging setup at the Beijing Synchrotron Radiation Facility for simple model and insect samples. The results show that to obtain clear phase-contrast images of biologic tissues for the X-ray in-line imaging setup, with determined parameters such as the size of the X-ray source, the pixel size of the detector and the fixed source-to-sample distance, there is a range of optimized sample-to-detector distances. The analysis method discussed in this article can be helpful in optimizing the setup of X-ray in-line phase-contrast imaging. 展开更多
关键词 X-ray phase contrast imaging edge-contrast enhancement spatial resolution
原文传递
An Improved Phase Retrieval Algorithm for X-ray In-line Phase-Contrast Imaging
18
作者 GUO Yun-feng ZHUANG Tian-ge SUN Jian-qi 《Chinese Journal of Biomedical Engineering(English Edition)》 CSCD 2016年第2期69-75,共7页
Phase contrast imaging technique has been improved promptly in recent years. Among these techniques in-line phase-contrast imaging is widely used. Various algorithms for in-line phase retrieval have been proposed so f... Phase contrast imaging technique has been improved promptly in recent years. Among these techniques in-line phase-contrast imaging is widely used. Various algorithms for in-line phase retrieval have been proposed so far such as TIE(transport of intensity equation), CTF(contrast transfer function), first born-approximations, GSF(Gerchberg-Saxton-Fienup), etc. Bronnikov's algorithm(BA) is a type of linear algorithm that is simple and efficient. But it can only be used without absorption situations. In this paper, an improved algorithm based on BA was presented. The approach adds Δφ(x,y) to the phase map φ_b(x,y) retrieved by BA to make the reconstructed phase map more precise. Further, the approach was evaluated on simulated images and confirmed to be accurate at higher absorption rates. 展开更多
关键词 IN-LINE phase contrast imaging phase retrieval improved algorithm
在线阅读 下载PDF
相位对比CT技术用于三维可视化急性肝损伤小鼠模型离体肝内脉管及坏死灶
19
作者 王子博 杜先勤 +3 位作者 辛晓红 赵新颜 胡春红 吕文娟 《中国医学影像技术》 北大核心 2025年第10期1648-1652,共5页
目的观察相位对比CT技术用于三维可视化急性肝损伤(ALI)小鼠模型离体肝内脉管及坏死灶的可行性。方法将6只清洁级雄性野生型C57BL/6小鼠随机均分为模型组与对照组,每组3只。对模型组饲喂过量对乙酰氨基酚以诱导ALI模型,对照组饲喂等量... 目的观察相位对比CT技术用于三维可视化急性肝损伤(ALI)小鼠模型离体肝内脉管及坏死灶的可行性。方法将6只清洁级雄性野生型C57BL/6小鼠随机均分为模型组与对照组,每组3只。对模型组饲喂过量对乙酰氨基酚以诱导ALI模型,对照组饲喂等量蒸馏水;24 h后处死小鼠并取出肝脏进行固定、脱水等处理。针对2组离体肝脏采集相位对比CT并重建断层及三维图像。观察相位对比CT显示肝脏轮廓及其内脉管、坏死灶效果,定量分析坏死灶最大直径及体积,并将CT与病理所见进行对照分析。结果相位对比CT原始投影及断层图像清晰显示离体肝脏轮廓及内部脉管系统。模型组肝内存在、而对照组未见坏死区域,且相位对比CT与病理所见精准对应。相位对比CT三维重建图清晰显示2组肝内门静脉及肝静脉系统。模型组肝脏见不连续点状坏死灶,主要分布于肝静脉周围,其中位最大径18.50μm、中位体积5870.11μm 3;对照组肝内未见坏死灶。结论相位对比CT技术可用于三维可视化ALI小鼠模型离体肝脏内部脉管及坏死灶。 展开更多
关键词 小鼠 肝疾病 坏死 相位对比CT
暂未订购
腹部双能CT虚拟平扫各期相的图像质量与辐射剂量的对比研究
20
作者 李妍 袁颖 张浩琦 《中国CT和MRI杂志》 2025年第11期151-154,共4页
目的探究在对腹部进行双能CT(Dual energy CT,DECT)虚拟平扫(virtual non-contrast,VNC)时各期相图像质量和辐射质量的对比。方法对21例患有腹部病变需要做增强CT检查的患者应用双能CT虚拟平扫技术,进行真实平扫(true non-contrast,TNC... 目的探究在对腹部进行双能CT(Dual energy CT,DECT)虚拟平扫(virtual non-contrast,VNC)时各期相图像质量和辐射质量的对比。方法对21例患有腹部病变需要做增强CT检查的患者应用双能CT虚拟平扫技术,进行真实平扫(true non-contrast,TNC)以及常规三期扫描。对获得的真实平扫图像以及动脉期、门脉期、延迟期的虚拟平扫图像进行对比研究,记录其四组图像肝门层面中的肝右叶、肝左叶、脾脏、下腔静脉、竖脊肌、皮下脂肪的CT值、SD值、信噪比(signal-to-noise ratio,SNR)及对比噪声比(contrast-to-noise ratio,CNR),并选择肝门层面测量整个扫描过程和平扫期对应的仪器自动生成的剂量长度乘积(Dose Length Product,DLP)、有效剂量(Effective Dose,ED)。分析以上图像数据、主观评分等有无统计学意义。结果四组图像的肝右叶、肝左叶CT值无统计学意义(P>0.05),脾脏、下腔静脉CT值有差异,有统计学意义(P<0.05)。四组图像的肝左叶SD值无显著差异(P>0.05),肝右叶、脾脏、下腔静脉的SD值有显著性差异(P<0.05)。四组图像中肝右叶、肝左叶、脾脏、下腔静脉的SNR值均无显著性差异(P>0.05),四组图像中肝右叶、肝左叶、脾脏的CNR值均无显著性差异(P>0.05),下腔静脉处的CNR值存在显著性差异(P<0.05)。两种扫描模式所产生的辐射剂量有显著性差异,有统计学意义(P<0.05)。结论运用双能CT虚拟平扫技术对腹部有病变的患者进行扫描检查之后,肝脏部位的真实平扫图像和三期虚拟平扫图像质量相似,此项技术对于肝脏的检查意义较大。双能CT虚拟平扫技术在降低辐射剂量总量这一方面也提供了很好的一个途径。总体而言,门脉期虚拟平扫图像更接近真实平扫图像所达到的效果。 展开更多
关键词 腹部 双能CT 虚拟平扫 期相对比
暂未订购
上一页 1 2 42 下一页 到第
使用帮助 返回顶部