Design of a Control Device for Synthetic Making Test Based on Pre-Arcing Current Detection and Phase Control 被引量:1
1
作者 Zhengyang ZHOU Minfu LIAO Xingming FAN 《Journal of Electromagnetic Analysis and Applications》 2009年第4期279-283,共5页
The synthetic making test has been widely used in evaluating the break ability of high-voltage circuit breaker. However, the test research and application are still inadequate, especially in the condition of rated vol... The synthetic making test has been widely used in evaluating the break ability of high-voltage circuit breaker. However, the test research and application are still inadequate, especially in the condition of rated voltage. According to the realistic conditions of test stations in China, a control device based on pre-arcing current detection and phase control is proposed in this paper. A sample of the control device made up of DSP TMS320LF2407A is fabricated, in which the CPLD MAX7064 is used to transmit signals for EMC design. It can be applied in full voltage synthetic making test at a level of 126kV/63kA. The test results show that, it is accurate to control the making phase of the applied voltage, whether the closing is demanded at voltage peak or zero. 展开更多
关键词 SYNTHETIC MAKING Test Pre-Arcing current phase control
暂未订购
Feedback Control System for Antenna Phase Difference in the LHCD Experiments
2
作者 蒋敏 匡光力 +3 位作者 单家芳 林建安 孔军 HT-7 Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第6期3107-3110,共4页
It is well accepted that lower hybrid current drive (LHCD) is the most efficient method for non-inductive current drive in fusion devices and the effect of the current drive is dependent on not only microwave power ... It is well accepted that lower hybrid current drive (LHCD) is the most efficient method for non-inductive current drive in fusion devices and the effect of the current drive is dependent on not only microwave power but also its grill phase shift. This paper presents a new kind of feedback control system for antenna phase difference in LHCD experiments. In this highspeed control system, a lot of new technologies and methods are incorporated. The results of the experiments show a very good agreement with the system design. 展开更多
关键词 lower hybrid current drive (LHCD) feedback control system antenna phase difference
在线阅读 下载PDF
弱电网下跟网型变流器锁相环与电流环控制耦合研究
3
作者 周金鹏 陈国初 《上海电机学院学报》 2026年第1期12-18,共7页
为抑制弱电网环境下锁相环对跟网型变流器电流环的影响,本文提出一种基于锁相环小信号扰动的补偿策略。首先,建立锁相环影响的电流环系统小信号模型,分析得到锁相环对电流环控制的扰动因子;其次,通过补偿不同的扰动因子,分别构建并网逆... 为抑制弱电网环境下锁相环对跟网型变流器电流环的影响,本文提出一种基于锁相环小信号扰动的补偿策略。首先,建立锁相环影响的电流环系统小信号模型,分析得到锁相环对电流环控制的扰动因子;其次,通过补偿不同的扰动因子,分别构建并网逆变器的输出阻抗模型;最后,利用改进型奈奎斯特判据对比分析不同补偿策略下并网逆变器的稳定裕度。仿真实验结果显示,在不改变锁相环结构和控制参数的情况下,同时对调制电压与反馈电流两者扰动都进行补偿的策略,可有效提升弱电网下并网逆变器的鲁棒性。 展开更多
关键词 弱电网 跟网型变流器 锁相环 电流环
在线阅读 下载PDF
基于电机驱动系统的DAB变换器控制优化方法
4
作者 李东东 刘晨亮 +1 位作者 吉裕晖 孙震威 《微特电机》 2026年第1期61-68,共8页
针对微特电机驱动控制系统中,双有源桥(dual active bridge,DAB)变换器在高频调制过程中易产生较大电流应力,导致器件温升高、寿命衰减及负载扰动下系统稳定性下降等问题,本文提出一种改进型双移相优化调制策略。该方法基于双有源桥拓扑... 针对微特电机驱动控制系统中,双有源桥(dual active bridge,DAB)变换器在高频调制过程中易产生较大电流应力,导致器件温升高、寿命衰减及负载扰动下系统稳定性下降等问题,本文提出一种改进型双移相优化调制策略。该方法基于双有源桥拓扑,建立双移相调制下的功率传输模型与电流应力数学模型,采用拉格朗日乘数法求解最优移相比组合,并进一步推导多功率场景下的电流应力解析表达式;在控制器设计方面,引入电感电流内环补偿机制,提高系统对电机驱动过程中负载变化的动态响应能力。MATLAB/Simulink仿真结果表明,该方法在典型微特电机负载工况下能有效降低变换器的电流应力,缩短暂态响应时间,并改善输出电压纹波,对提升微特电机控制系统的稳态与暂态性能具有良好效果,为高效能电机驱动供电模块的优化设计提供理论依据。 展开更多
关键词 微特电机 双有源桥拓扑 最优移相比 电流内环控制 暂态响应优化
在线阅读 下载PDF
基于控保协同的适配全比例新能源电网突变量选相元件能力恢复策略
5
作者 张林 王洪彬 +3 位作者 陈迅 林湘宁 李正天 魏繁荣 《电力科学与技术学报》 北大核心 2026年第1期53-62,共10页
逆变电源在故障时采取负序抑制控制策略及低电压穿越控制策略,导致全比例新能源系统中储能场站侧正、负序电流分布系数严重不相等,引发相电流差突变量选相元件不正确选相。基于故障序分量网络,推导了相电流差突变量选相元件正确选相的... 逆变电源在故障时采取负序抑制控制策略及低电压穿越控制策略,导致全比例新能源系统中储能场站侧正、负序电流分布系数严重不相等,引发相电流差突变量选相元件不正确选相。基于故障序分量网络,推导了相电流差突变量选相元件正确选相的限制条件,提出一种基于故障分量调控的相电流差突变量选相元件性能恢复方案。该方案能消除由于正、负序电流分布系数不相等而引发的储能侧选相性能下降的问题。仿真结果表明,所提方案恢复了传统电流突变量选相元件在全比例新能源系统中储能侧的性能,使现有电流突变量选相方案仍能适应高渗透率甚至全比例新能源电网。 展开更多
关键词 孤岛系统 相电流差突变量选相 故障分量调控 控保协同 适应性分析
在线阅读 下载PDF
基于扩展移相的双有源桥DC-DC变换器电流应力优化与模型预测混合控制
6
作者 邹梓洋 张长征 +1 位作者 张杰 袁雷 《太阳能学报》 北大核心 2026年第1期386-394,共9页
为提升双有源桥DC-DC变换器在直流微电网发生扰动下的性能,该文针对双有源桥DC-DC变换器动态响应性能与应力优化问题展开研究,并提出一种新型混合控制策略。该策略融合了扩展移相调制和模型预测控制,旨在降低变换器电流应力,并通过优化... 为提升双有源桥DC-DC变换器在直流微电网发生扰动下的性能,该文针对双有源桥DC-DC变换器动态响应性能与应力优化问题展开研究,并提出一种新型混合控制策略。该策略融合了扩展移相调制和模型预测控制,旨在降低变换器电流应力,并通过优化控制提升动态响应与稳态精度。此外,鉴于模型预测控制对参数的敏感性,引入误差校正方法作为反馈校正环节,以消除因参数失配所引起的稳态误差,从而提高系统的控制精度与系统鲁棒性。仿真与实验均验证了所提控制策略的实用性与优越性。 展开更多
关键词 DC-DC变换器 模型预测控制 微电网 电流应力优化 扩展移相
原文传递
基于增量式全局优化的双三相PMSM模型预测电流控制
7
作者 谢凝子 肖岚 +1 位作者 伍群芳 王勤 《电力电子技术》 2026年第2期129-136,共8页
目前双三相永磁同步电机(PMSM)多矢量模型预测电流控制(MPCC)方法通常在选择最优矢量后进行占空比分配,导致合成电压矢量不一定是全局最优,而进行占空比分配后再选择最优矢量会导致计算负担大的问题。对此,本文提出了一种无差拍电压预... 目前双三相永磁同步电机(PMSM)多矢量模型预测电流控制(MPCC)方法通常在选择最优矢量后进行占空比分配,导致合成电压矢量不一定是全局最优,而进行占空比分配后再选择最优矢量会导致计算负担大的问题。对此,本文提出了一种无差拍电压预测下的全局优化多矢量控制方法,通过结合无差拍预测方法计算电压参考矢量并将占空比分配结果代入价值函数,从而提高预测精度并降低计算量。由于模型准确性影响模型预测精度,本文基于迭代思想利用相邻两个预测周期之差得到增量式预测方程,消除预测方程磁链项,提高了磁链鲁棒性。最后通过实验验证了所提方法与传统方法对比q轴电流脉动降低49.57%,d轴脉动降低7.7%,相电流总谐波畸变率(THD)降低49%,并且在磁链失配情况下q轴电流能准确跟踪给定值。 展开更多
关键词 双三相永磁同步电机 多矢量模型预测电流控制 无差拍 增量式
在线阅读 下载PDF
角接五相电机单相开路故障零序环流抑制方法
8
作者 周亚蒙 田兵 +1 位作者 谭强 王涛 《电力工程技术》 北大核心 2026年第2期60-69,共10页
角接五相电机在单相绕组开路故障下存在典型零序环流,会引起相电流畸变和转矩波动等问题。为此,文中提出一种近似线性化控制方法,并结合比例-积分(proportional-integral,PI)控制实现对交变零序环流的有效抑制。首先,基于现有的星接五... 角接五相电机在单相绕组开路故障下存在典型零序环流,会引起相电流畸变和转矩波动等问题。为此,文中提出一种近似线性化控制方法,并结合比例-积分(proportional-integral,PI)控制实现对交变零序环流的有效抑制。首先,基于现有的星接五相电机容错控制模型,通过增设绕组相电流和电压的变换矩阵,给出一种角接五相电机的容错解耦控制方案;然后,推导零序环流和零序电磁转矩的非线性数学模型,并依据位置角度细分方法将非线性零序模型近似线性化,结合多维度PI控制器实现零序环流抑制;最后,进行仿真验证。实验结果表明,零序环流在未抑制前呈现具有一定幅值且基频波动的交流特性,在实行抑制方法之后,零序环流近乎为0。相电流由抑制前的严重失衡和幅值过大状态转变为正常状态,转矩波动问题也明显改善。因此,在角接五相电机发生单相开路故障时,可以使用主动抑制零序环流的容错控制方法改善相电流畸变和转矩波动问题。 展开更多
关键词 角接五相电机 容错控制 零序环流 近似线性化 比例-积分(PI)控制 矢量控制
在线阅读 下载PDF
基于多调制模式的五相串绕组逆变器电路电流谐波抑制控制
9
作者 黄润东 刘森轶 刘春华 《中国电机工程学报》 北大核心 2026年第2期799-811,I0030,共14页
与传统三相永磁同步电机相比,多相永磁同步电机(permanent magnet synchronous motors,PMSMs)在相同工况下具有较低的电压等级,且容错能力更强。为进一步降低对母线电压的要求,提高母线电压利用率,该文采用串联绕组(series-end winding,... 与传统三相永磁同步电机相比,多相永磁同步电机(permanent magnet synchronous motors,PMSMs)在相同工况下具有较低的电压等级,且容错能力更强。为进一步降低对母线电压的要求,提高母线电压利用率,该文采用串联绕组(series-end winding,SW)逆变器电路代替星形连接绕组逆变器电路。然而,在SW逆变器电路中电机各相绕组首尾相连,引入零序回路,将导致各相绕组中存在零序电流(zero-sequence current,ZSC)。因此,该文提出一种基于多调制模式的五相PMSM串绕组逆变器电路谐波电流抑制方法。该方法基于模型预测控制,考虑在SW驱动下的所有电压矢量,选取最优的调制模式进行谐波电流抑制。在获得参考电压的过程中,根据电机模型进行延时补偿。由于五相SW逆变器电路产生的电压矢量较多,可根据最外围矢量分成12个扇区,每个扇区有7个矢量。因此,确定参考电压所在扇区后,需计算该扇区不同调制组合下的电机预测电流。根据代价函数得到最小谐波电流对应的调制模式。该控制策略在减小谐波电流的同时,减少了预测电流的计算次数。 展开更多
关键词 多调制模式 五相永磁同步电机 谐波电流抑制控制 串绕组逆变器
原文传递
双三相永磁电机的容错型多矢量预测电流控制
10
作者 周湛清 苏猛 《天津工业大学学报》 北大核心 2026年第1期47-55,共9页
为充分利用双三相永磁同步电机发生开路故障后谐波平面残存的控制自由度,并提升模型预测电流控制算法的稳态性能,提出了一种适用于双三相电机的容错型预测电流算法。通过分别在基波平面与谐波平面合成虚拟矢量,实现了基波平面与谐波平... 为充分利用双三相永磁同步电机发生开路故障后谐波平面残存的控制自由度,并提升模型预测电流控制算法的稳态性能,提出了一种适用于双三相电机的容错型预测电流算法。通过分别在基波平面与谐波平面合成虚拟矢量,实现了基波平面与谐波平面的解耦控制;借助占空比调制技术实现了谐波平面闭环控制,驱动电机运行在最大转矩或最小铜损运行模式下,优化了电机运行效率;针对有限集模型预测控制中基波电流控制自由度受限、稳态调节精度差等问题,通过多虚拟矢量输出模式,有效提升了电机稳态性能,并保证了模型预测控制优良的动态性能。实验结果表明:相比于现有改进策略,所提控制策略在最小铜损运行模式与最大转矩运行模式下的相电流总谐波失真分别降低约44.5%和25.7%;同时,2种运行模式下的q轴电流波动分别降低约31.7%和28.0%,转矩波动分别降低约31.4%和25.1%,有效改善了故障后电机的运行品质。 展开更多
关键词 双三相永磁同步电机 模型预测电流控制 开路故障 虚拟矢量 占空比调制
在线阅读 下载PDF
高压直流输电直流线路故障穿越重启策略 被引量:4
11
作者 卢东斌 黄志岭 +3 位作者 龚飞 李海英 卢宇 凌建 《高电压技术》 北大核心 2025年第2期828-839,I0023-I0026,共16页
高压直流输电系统在发生直流线路故障时,采用移相重启策略,通过控制整流器移相,快速抑制故障电流,经去游离时间后,解除移相,重启高压直流输电系统。但是,移相重启时,整流器和逆变器都不再消耗无功功率,换流站的交流滤波器将向交流系统... 高压直流输电系统在发生直流线路故障时,采用移相重启策略,通过控制整流器移相,快速抑制故障电流,经去游离时间后,解除移相,重启高压直流输电系统。但是,移相重启时,整流器和逆变器都不再消耗无功功率,换流站的交流滤波器将向交流系统提供盈余的无功功率,易导致交流系统过电压;对于对称单极拓扑结构,还将导致非故障线路不能传输有功功率,从而对交流系统产生很大的有功功率冲击。该文提出了直流线路故障穿越重启策略,在直流线路故障时,通过控制故障两端的整流器和逆变器的直流电流相等,在控制故障点电流为零的同时,直流电流穿越故障,继续维持无功功率消耗,避免交流系统产生过电压;对于对称单极拓扑结构,还可以利用故障极续流,继续输送部分有功功率。 展开更多
关键词 高压直流输电 直流线路故障 移相重启 电流控制 穿越重启 交流过电压 去游离时间 直流电弧
原文传递
Analysis of a novel phase-shifted soft switch converter
12
作者 蒋志宏 黄立培 张义 《China Welding》 EI CAS 2002年第1期67-71,共5页
In this paper, on the basis of the phase shifted controlled zero voltage switch (ZVS) full bridge converter with pulse width modulation (PWM), a novel zero voltage and zero current switch (ZVZCS) PWM converter u... In this paper, on the basis of the phase shifted controlled zero voltage switch (ZVS) full bridge converter with pulse width modulation (PWM), a novel zero voltage and zero current switch (ZVZCS) PWM converter using a simple auxiliary circuit was designed. The ZVZCS soft switch is achieved by the resonance among the resisting electromagnetic deflection capacitor, the capacitor of the simple auxiliary network and the leakage inductor of transformer. There are no dissipation devices of the saturation inductor and the auxiliary switch in the converter, meantime the capacitor of the auxiliary circuit is also used to clamp the voltage of the rectifier, and there is no additional clamped circuit. There is no big circulating current in the converter, all the active and passive devices work on the condition of the low current and voltage stress, and the proposed converter has wide load range and small duty loss. 展开更多
关键词 phase shifted control ZERO voltage and zero current switch
在线阅读 下载PDF
混合三电平双有源桥变换器超螺旋滑模自抗扰控制策略
13
作者 刘春喜 田迎澳 王涛 《电子测量与仪器学报》 北大核心 2025年第10期209-219,共11页
针对混合三电平双有源桥变换器电流应力大以及动态响应差的问题,对扩展移相调制进行改进,提出一种基于超螺旋滑模自抗扰控制器的最小电流应力控制策略。首先,通过重新定义内、外移相比改进扩展移相调制,以实现移相比与传输功率正相关,... 针对混合三电平双有源桥变换器电流应力大以及动态响应差的问题,对扩展移相调制进行改进,提出一种基于超螺旋滑模自抗扰控制器的最小电流应力控制策略。首先,通过重新定义内、外移相比改进扩展移相调制,以实现移相比与传输功率正相关,并降低移相比间的耦合度;其次,分析改进扩展移相调制在不同工作模式下的传输功率和电流应力的数学模型,并采用KKT条件法求解考虑软开关条件的最小电流应力移相比组合;然后,为简化计算,建立变换器的降阶模型,将超螺旋滑模控制算法与自抗扰技术相结合,以改善变换器的动态性能;最后,通过搭建实验样机进行验证,结果表明,超螺旋滑模自抗扰控制与传统自抗扰控制相比,负载电阻突减时所需的调节时间缩短了72.4%,电压波动减小了51.7%;输入电压突变时所需调节时间缩短了73.7%,电压波动减小了60%。同时有效减小了电流应力并实现了软开关,与单移相调制相比,低功率下效率提高了15%,高功率下效率提高了9%。 展开更多
关键词 超螺旋滑模控制 自抗扰控制 混合三电平双有源桥变换器 改进扩展移相调制 电流应力
原文传递
基于新型双重移相下双有源桥最小电流应力优化方法
14
作者 荆鹏辉 李斌 《电机与控制学报》 北大核心 2025年第9期127-137,共11页
针对双有源全桥变换器在双重移相控制方法下轻载区和半载区电流应力过大的问题,提出一种基于新型双重移相调制的分段式电流应力控制策略。首先,基于开关管的通断顺序重新定义内外移相比,通过合理的顺序组合避免了传统双重移相中电感电... 针对双有源全桥变换器在双重移相控制方法下轻载区和半载区电流应力过大的问题,提出一种基于新型双重移相调制的分段式电流应力控制策略。首先,基于开关管的通断顺序重新定义内外移相比,通过合理的顺序组合避免了传统双重移相中电感电流增速最快的开关状态。接着,分析变换器2种工作模式下电感电流应力与移相比、传输功率和电压转换比之间的数学关系,通过寻优求得最优移相比,根据不同模式下移相比的约束条件对传输功率区间进行分段式电流应力优化控制,设计直接功率控制的输出电压闭环控制方法。在给定传输功率条件下与传统双重移相控制策略进行对比分析,当变换器工作在非重载区且电压转换比较大时,该控制策略对抑制电流应力有显著优势。最后,搭建实验样机验证理论分析的正确性及可行性。 展开更多
关键词 双有源全桥变换器 新型双重移相 电流应力 约束条件 优化控制
在线阅读 下载PDF
大功率宽输出电压双有源桥DC‑DC变换器最小电流应力优化策略
15
作者 赵阳 胡锴强 《武汉大学学报(工学版)》 北大核心 2025年第6期959-970,共12页
在设计和研发大功率宽输出电压范围的双有源桥(dual active bridge,DAB)变换器时,传统的电流应力优化策略往往只关注移相比优化,忽略了电感量变化对电流应力的影响,这可能导致在大功率应用中电流应力超出理论预期,从而降低开关管的可靠... 在设计和研发大功率宽输出电压范围的双有源桥(dual active bridge,DAB)变换器时,传统的电流应力优化策略往往只关注移相比优化,忽略了电感量变化对电流应力的影响,这可能导致在大功率应用中电流应力超出理论预期,从而降低开关管的可靠性。因此,在大功率应用场景下,为使变换器在全功率范围内获得最小电流应力,首先提出了考虑电感量随电流应力变化的动态关系,并基于此关系选择在恰当电感量下的优化三移相控制方法;其次,通过分析三移相控制并建立相应的数学模型,利用KKT(Karush-Kuhn-Tucker)条件寻求最优移相比组合,以实现电流应力优化;最后,搭建额定功率为100 kW的DAB变换器仿真模型及样机实验平台进行验证。实验结果表明,与传统三移相控制方法相比,所提方法在仿真和实验中都表现出较高的有效性,确保了变换器在整个运行过程中电流应力始终保持在理论预期范围内,保证了变换器在稳定运行时开关管的可靠性。 展开更多
关键词 双有源桥变换器 最优电感量 优化三移相控制 最小电流应力
原文传递
考虑不同优化指标的双有源桥变换器全局优化控制 被引量:1
16
作者 王祺 张泽轲 王春花 《电力系统保护与控制》 北大核心 2025年第5期113-122,共10页
双有源桥(dual-active-bridge,DAB)变换器在能量双向传输的场合扮演着关键的角色,其中单移相控制是其最典型的控制方式。然而,当DAB变换器的输入电压和输出电压不匹配时会产生较大的回流功率,同时会增大电流应力,轻载时无法实现全部开... 双有源桥(dual-active-bridge,DAB)变换器在能量双向传输的场合扮演着关键的角色,其中单移相控制是其最典型的控制方式。然而,当DAB变换器的输入电压和输出电压不匹配时会产生较大的回流功率,同时会增大电流应力,轻载时无法实现全部开关管的零电压开通(zero-voltage-switching,ZVS)。针对传统单移相控制在电压不匹配运行时效率降低的问题,提出一种基于双重移相(dual-phase-shift,DPS)控制的全功率范围内保证全部开关管实现ZVS的最小回流功率优化策略,以提高变换器在宽电压调节比下的效率。首先,综合考虑功率的传输特性、电压调节比以及最小回流功率、最小电流应力、全ZVS三者之间的耦合关系,研究全部开关管实现ZVS的功率范围。然后,根据给定的约束条件,通过分段优化的方法,得到全局最优解。最后,搭建实验平台验证所提优化策略在电压不匹配运行条件下可以使DAB变换器的全部开关管在全功率范围内均能实现ZVS,同时减小了回流功率。 展开更多
关键词 双有源桥变换器 回流功率 电流应力 软开关 双重移相控制
在线阅读 下载PDF
基于xy平面闭环电流控制的双三相永磁同步电机改进多矢量模型预测控制 被引量:1
17
作者 徐奇伟 易良武 +2 位作者 夏波 苗轶如 蔡华祥 《电工技术学报》 北大核心 2025年第14期4506-4521,共16页
双三相永磁同步电机(DTP-PMSM)多矢量模型预测电流控制(MPCC)可以解决单矢量MPCC存在的电流和转矩谐波问题。但是传统DTP-PMSM多矢量MPCC仍然具有计算负担重、易受非理想因素影响和xy平面电流谐波大的问题。为此,该文提出一种基于xy平... 双三相永磁同步电机(DTP-PMSM)多矢量模型预测电流控制(MPCC)可以解决单矢量MPCC存在的电流和转矩谐波问题。但是传统DTP-PMSM多矢量MPCC仍然具有计算负担重、易受非理想因素影响和xy平面电流谐波大的问题。为此,该文提出一种基于xy平面闭环电流控制的DTP-PMSM改进多矢量MPCC策略。首先采用广义比例积分观测器(GPIO)观测集总扰动并更新预测模型,提高αβ平面电流的控制性能。然后采用αβ平面最外层基本电压矢量合成xy平面的虚拟电压矢量,在不引入额外电压矢量的前提下,实现对xy平面电流的闭环控制,并推导得到脉冲信号的开关序列以及各矢量的作用时间。实验结果表明,所提方法不仅能够减少控制算法的计算时间,提升αβ平面电流的控制性能,还能抑制xy平面谐波电流。同时,该文所提出的xy平面闭环电流控制策略不影响αβ平面MPCC的性能。 展开更多
关键词 双三相永磁同步电机 模型预测电流控制 谐波电流抑制 多虚拟电压矢量优化
在线阅读 下载PDF
基于有功-无功联合控制的构网型变流器暂态稳定性提升方法 被引量:3
18
作者 夏向阳 赵晓悦 +3 位作者 梁军 罗文广 陈贵全 郑汉锋 《电力系统自动化》 北大核心 2025年第11期114-125,共12页
针对构网型变流器在电网对称故障下的暂态功角失稳和故障电流越限问题,提出了一种结合二阶滑模控制与电压自适应调节的联合控制方法。首先,在构网型变流器有功功率-频率环中引入改进型积分滑模面并构造李雅普诺夫函数,依据稳定性判据设... 针对构网型变流器在电网对称故障下的暂态功角失稳和故障电流越限问题,提出了一种结合二阶滑模控制与电压自适应调节的联合控制方法。首先,在构网型变流器有功功率-频率环中引入改进型积分滑模面并构造李雅普诺夫函数,依据稳定性判据设计输出功率控制律,在计及电网相位变化的同时严格限制故障期间变流器输出功角波动。其次,采用无功功率-电压环切换控制以提供稳定的无功功率,支撑并网点电压,同时确保故障电流维持在安全阈值之内。最后,仿真与实验结果表明:在电网电压严重跌落并伴随相位突变的情况下,所提策略仍能有效提升构网型变流器故障穿越能力及故障切除后的恢复速率,其精细化主动支撑特性也同样适用于高低压穿越的复杂工况。 展开更多
关键词 构网型变流器 暂态稳定性 二阶滑模控制 故障限流 电压跌落 相位突变
在线阅读 下载PDF
基于Prony算法的高直流分量短路故障电流相控开断研究 被引量:1
19
作者 马飞越 魏莹 +5 位作者 李龙启 王达奇 项彬 王东宇 杜慧鑫 刘志远 《电工电能新技术》 北大核心 2025年第4期91-99,共9页
快速地检测短路故障的起始时刻,准确估计出故障电流关键参数并预测出有效的短路电流过零点是实现短路故障电流相控开断的关键。目前,随着电网规模的不断扩大,发生短路故障时,电力系统等效非周期分量衰减常数不断增加,系统面临短路电流... 快速地检测短路故障的起始时刻,准确估计出故障电流关键参数并预测出有效的短路电流过零点是实现短路故障电流相控开断的关键。目前,随着电网规模的不断扩大,发生短路故障时,电力系统等效非周期分量衰减常数不断增加,系统面临短路电流非周期分量衰减常数超标的问题,部分电网已经超过150 ms,但是,针对高直流分量衰减时间常数的短路电流零点预测研究较少。基于此,本文选择Prony算法研究含高直流分量短路故障电流相控开断的零点预测方法。首先采用F_(0)假设检验检测短路故障的初始时刻,继而启动Prony算法预测短路电流零点,经延时时间后控制断路器在较短燃弧时间开断。结果表明Prony算法适用于高直流分量衰减时间常数下短路故障的零点预测,其参数计算误差和零点预测误差小,波形拟合度高。对不同基波起始相角和直流衰减时间常数短路电流仿真,Prony算法零点预测产生的误差在±0.5 ms以内,并通过录波验证了算法的可行性。在相同参数情况下,采样时间5 ms的Prony算法零点预测效果优于递推最小二乘算法。 展开更多
关键词 故障电流相控开断 PRONY算法 F_(0)假设检验 过零点预测 递推最小二乘算法
在线阅读 下载PDF
基于过谐振调频扩展移相控制的CLLC谐振变换器电流优化策略 被引量:3
20
作者 王翌琛 王丰 +1 位作者 卓放 于克凡 《电力系统自动化》 北大核心 2025年第3期178-188,共11页
电容-电感-电感-电容(CLLC)谐振变换器是一种运行效率高、软开关特性好,适用于直流电力系统的隔离型双向DC/DC变换器。然而,谐振变换器采用的传统调频控制仅包含一个控制变量,难以同时维持变换器输出电压稳定并兼顾谐振电流优化。为了提... 电容-电感-电感-电容(CLLC)谐振变换器是一种运行效率高、软开关特性好,适用于直流电力系统的隔离型双向DC/DC变换器。然而,谐振变换器采用的传统调频控制仅包含一个控制变量,难以同时维持变换器输出电压稳定并兼顾谐振电流优化。为了提升CLLC谐振变换器的整体运行效率,提出了一种基于粒子群优化算法的过谐振调频扩展移相控制方法。此控制方法在调频控制的基础上引入了2个移相型控制变量,增加了CLLC谐振变换器的控制自由度。同时,基于精准时域模型并使用粒子群优化算法,可以明确变换器采用过谐振调频扩展移相控制方法时的最优工作点,从而有效地提升变换器不同工况下的运行效率。最后,通过一台2kW级实验样机验证了所提电流优化方法的可行性。 展开更多
关键词 直流电力系统 谐振变换器 粒子群优化算法 过谐振调频扩展移相控制 谐振电流优化 时域模型
在线阅读 下载PDF