Thermal expansion is a common phenomenon in both metals and alloys, which is important for metallic material applications in modern industry, especially in nuclear and aerospace industries. A lower thermal expansion c...Thermal expansion is a common phenomenon in both metals and alloys, which is important for metallic material applications in modern industry, especially in nuclear and aerospace industries. A lower thermal expansion coefficient may cause lower thermal stress and higher accuracy. A new Zr-based alloy is developed and presented.The XRD diffraction results demonstrate that only a close-packed hexagonal phase(α or α' phase) exists in the microstructure. The thermal expansion and mechanical properties are studied. According to the experimental results, the new Zr-based alloy presents a low thermal expansion coefficient and good mechanical properties.Also,its thermal expansion coefficient is stable through solution treatment.展开更多
We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the...We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the practicality from the experimental results. The reactor module employed was an aluminum plate-tube heat exchanger with corrugated fins, and the CaCl<sub>2</sub> powder was in the form of a packed bed. Heat storage operation and heat dissipation operation are performed at the same time and supplied to the heat demand destination. At this time, an environmental heat source can be used during the heat radiation operation, and the heat output can release more heat than the heat input during heat storage. The heat discharging and charging characteristics of the reactor module were evaluated experimentally. The coefficient of performance (COP) was calculated for the heat upgrading cycle, and the heat output in the system was determined. A COP of 1.42 and output of 650 W/L, based on the heat exchanger volume, were obtained using a 600 s change time for the heat pump.展开更多
Although a new-class of heat pumps based on mechanically flexible nanoporous materials holds great poten-tial for the utilization of sustainable refrigerants with a considerably high coefficient of performance(COP),re...Although a new-class of heat pumps based on mechanically flexible nanoporous materials holds great poten-tial for the utilization of sustainable refrigerants with a considerably high coefficient of performance(COP),reducing their system volume remains a challenge.In this study,we explored the potential of this innovative type of heat pump in terms of COP and system volume.To broaden the scope of material exploration,we devised a new thermodynamic heat pump system applicable to soft mesoporous materials,in addition to the conventional system that is suitable only for flexible microporous materials.Several key factors have been identified through the comparison of various nanoporous materials and refrigerants.Our systematic investigation reveals that the combination of mechanically softer nanoporous materials with ammonia refrigerants can achieve a high COP and a reduced system volume.展开更多
This paper studies the evaluation method of the performances of corporation that was set up by the Financial Ministry in 1999, and then analyzes the advantages and the problems of the method. Finally, this paper studi...This paper studies the evaluation method of the performances of corporation that was set up by the Financial Ministry in 1999, and then analyzes the advantages and the problems of the method. Finally, this paper studies the theoretical method of the evaluation of the performances of corporation.展开更多
In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis ...In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis and calculations on two combination ways by adding the compressor in the high-pressure area and in the low-pressure area are conducted respectively.The effects of several factors including the evaporation temperature Te heat-source temperature Th as well as the cooling water temperature Tw on the equivalent heat consumption in compression qCW heat consumption in absorption qG and the system coefficient of performance COP are analyzed under the two combination configurations.The results show that the effect of the equivalent heat consumption in compression on the COP is less than that of the heat consumption in absorption.Besides the compressor set in the high-pressure area uses more energy than that in the low-pressure area. Moreover the compressor in the low-pressure area is superior to that in the high-pressure area with respect to the COP. Under the given intermediate pressure there is an optimum heat-source temperature corresponding to the maximum COP of the AWA/CCR cycle.展开更多
Based on electron transport theory, the performance of kx and kr filtered thermoelectric refrigerators with two resonances are studied in this paper. The performance characteristic curves between the cooling rate and ...Based on electron transport theory, the performance of kx and kr filtered thermoelectric refrigerators with two resonances are studied in this paper. The performance characteristic curves between the cooling rate and the coefficient of performance are plotted by numerical calculation. It is shown that the maximum cooling rate of the thermoelectric refrigerator with two resonances increases but the maximum coefficient of performance decreases compared with those with one resonance. No matter which resonance mechanism is used (kx or kr filtered), the cooling rate and the performance coefficient of the kr filtered refrigerator are much better than those of the kx filtered one.展开更多
In this paper, the theoretical analysis and simulating calculation were conducted for a basic two-stage semiconductor thermoelectric module, which contains one thermocouple in the second stage and several thermocouple...In this paper, the theoretical analysis and simulating calculation were conducted for a basic two-stage semiconductor thermoelectric module, which contains one thermocouple in the second stage and several thermocouples in the first stage. The study focused on the configuration of the two-stage semiconductor thermoelectric cooler, especially investigating the influences of some parameters, such as the current I1 of the first stage, the area A1 of every thermocouple and the number n of thermocouples in the first stage, on the cooling performance of the module. The obtained results of analysis indicate that changing the current I1 of the first stage, the area A1 of thermocouples and the number n of thermocouples in the first stage can improve the cooling performance of the module. These results can be used to optimize the configuration of the two-stage semiconductor thermoelectric module and provide guides for the design and application of thermoelectric cooler.展开更多
In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1...In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400-2600 r/min), ambient air temperature(2.4-17.8 ℃) and condenser water inlet temperature(30-50℃). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance(COP) and system primary energy ratio(PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 ℃ to 17.8 ℃, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 ℃ to 50 ℃. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature.展开更多
Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe...Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.展开更多
In the present study,an attempt ismade to enhance the performance of heat pump by utilizing two types of nanofluids namely,copper and alumina nanofluids.These nanofluids were employed around the evaporator coil of the...In the present study,an attempt ismade to enhance the performance of heat pump by utilizing two types of nanofluids namely,copper and alumina nanofluids.These nanofluids were employed around the evaporator coil of the heat pump.The nanofluids were used to enhance the heat input to the system by means of providing an external jacket around the evaporator coil.Both the nanofluids were prepared in three volume fractions 1%,2%and 5%.Water was chosen as the base fluid.The performance of the heat pump was assessed by calculating the coefficient of performance of the system when it was operated with and without nanofluid jacket.A significant enhancement in the coefficient of performance was noticed when copper and alumina nanofluids were employed in the system.Also,the coefficient of performance was found to have a direct relationship with the tested volume fractions.For the highest volume fraction of 5%,the performance of the heat pump was found to enhance by 23%with alumina nanofluid,while for copper nanofluid,a very significant enhancement in performance by 72%was observed.Thus,utilizing of nanofluids in heat pumps can be very beneficial towards performance enhancement and the idea can also be extended to other thermal systems such as steam power plant,automobile radiator,industrial heat exchangers and refrigeration systems.展开更多
Cooling in industrial production and refrigeration of perishable and</span><span style="font-size:10.0pt;font-family:""> non-</span><span style="font-size:10.0pt;font-family:&q...Cooling in industrial production and refrigeration of perishable and</span><span style="font-size:10.0pt;font-family:""> non-</span><span style="font-size:10.0pt;font-family:""> </span><span style="font-size:10.0pt;font-family:"">perishable products is common practice throughout the world. Research studies have been conducted both experimentally and numerically to simulate Vapor Compression Refrigeration System (VCRS) and its performance respectively, however, experimental procedure often seems to be expensive and time-consuming to carry out due to the function of many variables. This study was therefore designed to numerically simulate the performance assessment of a nanoparticle enhanced VCRS. A numerical model of a vapor compression refrigeration system was developed using standard refrigeration equations on each of the major components of the refrigeration system such as compressor, evaporator, condenser and expansion valve. The model was then simulated on a MATLAB platform with a CoolProp installed packages via Python under two different simulation cases. In the first case, the mass fractions were varied for CuO,</span><span style="font-size:10.0pt;font-family:""> </span><span style="font-size:10.0pt;font-family:"">TiO<sub>2</sub> and Al<sub>2</sub>O<sub>3</sub> nanoparticles while their densities remained constant and a reversed condition was investigated for the second case. The results showed that both the refrigerating effect and the Coefficient Of Performance (COP) of the system increase as both the mass fraction and density of all the nanoparticles increases. It also shows that the compressor work decreases as both the mass fraction and density of all the nanoparticles were increased. On comparing the computational and numerical analysis results, the study established no significant difference in terms of COP and the use of nanoparticles were found to have improved the COP of the system.展开更多
In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study des...In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element.展开更多
With COP and dynamic characteristics in refrigeration cycle as criteria,a new metal hydride couple——LaNi 4.61 Mn 0.26 Al 0.13 /La 0.6 Y 0.4 Ni 4.8 Mn 0.2 was selected by establishing calculation procedure and metal ...With COP and dynamic characteristics in refrigeration cycle as criteria,a new metal hydride couple——LaNi 4.61 Mn 0.26 Al 0.13 /La 0.6 Y 0.4 Ni 4.8 Mn 0.2 was selected by establishing calculation procedure and metal hydride selection model.The experimental results show that the refigeration cycle of the selected couple is good in the performance.The recovered waste heat and refrigeration power from exhaust gas of several kinds of automobile are calculated by waste-heat formula,coefficient R Q and COP.Refrigeration cycle of the new couple can satisfy the air-conditioning requirement of truck and car and is not enough in passenger car,according to the respective cooling load.展开更多
A refrigerant mixture TJR02 was developed and the comparison experiment was performed on a singlestage vapor compression refrigeration system originally designed for R22.Experimental results show that TJR02 can be dir...A refrigerant mixture TJR02 was developed and the comparison experiment was performed on a singlestage vapor compression refrigeration system originally designed for R22.Experimental results show that TJR02 can be directly used in the system without modifying the original system or changing lubricant.By replacing R22 with TJR02,cooling rate gets faster and at least 20% of energy is saved.The actual detection in the standard test-bed verifies the experimental results and indicates that the adoption of TJR02 leads to greater efficiency and wider application.And the lower the refrigeratory temperature is,the more obvious the energy saving effects will be.展开更多
The thermodynamic cycle for an adsorption system is presented inp-T diagram. In order to investigate the performance of the adsorption system, a lumped parameter transient model of the chiller is developed, in order t...The thermodynamic cycle for an adsorption system is presented inp-T diagram. In order to investigate the performance of the adsorption system, a lumped parameter transient model of the chiller is developed, in order to predict the behaviors of the adsorption chiller system and find the influence of working conditions on its operation. For the working process of the main components of the system, including adsorber, condenser and evaporator, the coupled unsteady equations were set up for each stage. The model was then solved using stable numerical methods from EES (equation engineering solver), and the performance of the adsorber and condenser/evaporator of the system was analyzed. The condensation, evaporation and adsorber temperature values as well as the adsorption ratio and desorption ratio were obtained as function of operating time. Also, the coefficient of performance was analyzed in function of the heat source temperature and the cooling source temperature.展开更多
This study introduces a novel artificial heating technique aimed at addressing frost heave issues in embankments on frozen ground,offering a sustainable solution.Initial evaluations assessed various heating systems,in...This study introduces a novel artificial heating technique aimed at addressing frost heave issues in embankments on frozen ground,offering a sustainable solution.Initial evaluations assessed various heating systems,including boilers,heat pumps,solar heaters,and electric heaters,focusing on their thermal performance and applicability.The study subsequently designed and implemented a direct-expansion ground source heat pump(DX-GSHP)system as the primary heat source for embankment warming.Rigorous testing confirmed the DX-GSHP system's ability to maintain a heat-supply temperature above 40℃ and a heat-absorption temperature below -3.5℃,effectively extracting geothermal energy for transfer to the topsoil layers.With a demonstrated coefficient of performance(COP)of 3.49,the DX-GSHP system not only proves its energy efficiency but also suggests a potential role in reducing the strain on electricity supply systems.Installation of DX-GSHPs,with heating capacities ranging from 1.0 to 2.0 kW and spaced at intervals of 2.0-4.0 m,provides a rapid thermal response to frost heave in singletrack railway embankments,thereby potentially mitigating frost-induced damage in cold climate regions.展开更多
The use of air conditioning and refrigeration systems improved the standard of living. However, the system contributes to global warming by releasing potential global warming refrigerants directly and powering the sys...The use of air conditioning and refrigeration systems improved the standard of living. However, the system contributes to global warming by releasing potential global warming refrigerants directly and powering the system. There is an obligation, like UN Kyoto Protocol, EU MAC Directive and Japan METI Directive to find an alternative low-GWP refrigerant with excellent thermophysical properties. In this paper, the global warming effect of an air-conditioning system is analyzed theoretically using few low-GWP refrigerant mixtures. New refrigerant mixtures are formed based on low GWP, high volumetric capacity, and refrigerating effect. After analyzing, refrigerant blends of R1234yf/R32 (40/60, 50/50, and 60/40 by wt%) and R1234ze/R32 (40/60, 50/50, and 60/40 by wt%) are found promising to replace the widely used R410A. The best performance of the refrigerant blend is found for R1234yf/R32 (40/60). These analyses are crucial for selecting suitable refrigerants for domestic air conditioning systems.展开更多
R134a-DMF absorption heat pump unit is an energy-saving heat pump unit that can utilize renewable energy,and has great potential in the refrigeration and heating fields of urban and rural areas.The purpose of this art...R134a-DMF absorption heat pump unit is an energy-saving heat pump unit that can utilize renewable energy,and has great potential in the refrigeration and heating fields of urban and rural areas.The purpose of this article is to conduct in-depth research on the dynamic characteristics of absorption heat pump units based on R134a-DMF,a new working fluid pair.A mathematical model of the thermophysical properties of the R134a-DMF working fluid pair and the mathematical models of various components of the heat pump unit are constructed.This paper constructs a simulation program,and uses the Control variates to study the change trend of the Coefficient of performance of R134a-DMF absorption heat pump unit affected by the generator outlet concentrated solution temperature,condenser air volume and temperature rise,and chilled water outlet temperature.The results indicate that the established mathematical model for thermophysical properties and the unit model are both accurate models,which can provide guidance for the actual operation and optimization of R134a-DMF absorption heat pump units.Through simulation,it can be concluded that for the three combined forms of R134a DMF(3:2),R134a DMF(1:1),and R134a DMF(2:3),the average increase in COP and refrigeration capacity is 0.85%,0.39%,and 0.42%for each 1℃ increase in the outlet concentrated solution temperature of the generator,respectively,and the growth rate is relatively slow.The larger the proportion of refrigerant in the binary solution,the greater the COP of the unit under the same operating conditions.展开更多
A solution cooling absorption(SCA)approach is proposed to modify the aqueous ammonia absorption refrigerat-ion cycle using the strong solution from the absorber to cool the forepart of the absorption in the cycle fo...A solution cooling absorption(SCA)approach is proposed to modify the aqueous ammonia absorption refrigerat-ion cycle using the strong solution from the absorber to cool the forepart of the absorption in the cycle for reclaiming some portion of absorption heat.As a consequence of raised temperature at the inlet,the strong solution partially boils at the outlet of the solution heat exchanger,and diminishes the thermal heat consumption of the heat source.The calculation results show that the coefficient of performance(COP)of this modified cycle is about 28.3% higher than that of the traditional cycle under typical conditions;while the required heat transfer area of the total heat exchangers of the cycle is somewhat less than that of the traditional one.The capacity of refrigeration with the new absorption cycle is more than doubled in contrast to the adsorption scheme with an identical configuration.It is sufficient to supply a fishing boat the chilling capacity for preservation of fishing products with the modified cycle chiller driven by its diesel engine exhaust.展开更多
基金Supported by the Postdoctoral Science Foundation of Hebei Province under Grant No B2017003008the National Natural Science Foundation of China under Grant Nos 51531005,51671166,51571174 and 51604241the Natural Science Foundation of Hebei Province under Grant No E2016203395
文摘Thermal expansion is a common phenomenon in both metals and alloys, which is important for metallic material applications in modern industry, especially in nuclear and aerospace industries. A lower thermal expansion coefficient may cause lower thermal stress and higher accuracy. A new Zr-based alloy is developed and presented.The XRD diffraction results demonstrate that only a close-packed hexagonal phase(α or α' phase) exists in the microstructure. The thermal expansion and mechanical properties are studied. According to the experimental results, the new Zr-based alloy presents a low thermal expansion coefficient and good mechanical properties.Also,its thermal expansion coefficient is stable through solution treatment.
文摘We herein evaluate the use of a chemical heat pump (CHP) for upgrading waste heat. CaCl<sub>2</sub> was used in the system of CHP. We evaluated the heat storage and heat releasing of CHP, and confirmed the practicality from the experimental results. The reactor module employed was an aluminum plate-tube heat exchanger with corrugated fins, and the CaCl<sub>2</sub> powder was in the form of a packed bed. Heat storage operation and heat dissipation operation are performed at the same time and supplied to the heat demand destination. At this time, an environmental heat source can be used during the heat radiation operation, and the heat output can release more heat than the heat input during heat storage. The heat discharging and charging characteristics of the reactor module were evaluated experimentally. The coefficient of performance (COP) was calculated for the heat upgrading cycle, and the heat output in the system was determined. A COP of 1.42 and output of 650 W/L, based on the heat exchanger volume, were obtained using a 600 s change time for the heat pump.
文摘Although a new-class of heat pumps based on mechanically flexible nanoporous materials holds great poten-tial for the utilization of sustainable refrigerants with a considerably high coefficient of performance(COP),reducing their system volume remains a challenge.In this study,we explored the potential of this innovative type of heat pump in terms of COP and system volume.To broaden the scope of material exploration,we devised a new thermodynamic heat pump system applicable to soft mesoporous materials,in addition to the conventional system that is suitable only for flexible microporous materials.Several key factors have been identified through the comparison of various nanoporous materials and refrigerants.Our systematic investigation reveals that the combination of mechanically softer nanoporous materials with ammonia refrigerants can achieve a high COP and a reduced system volume.
文摘This paper studies the evaluation method of the performances of corporation that was set up by the Financial Ministry in 1999, and then analyzes the advantages and the problems of the method. Finally, this paper studies the theoretical method of the evaluation of the performances of corporation.
基金The National Natural Science Foundation of China(No.51176029)
文摘In view of different compressor adding ways in the ammonia-water absorption/compression combined refrigeration AWA /CCR cycle combining the Schulz state equation of the ammonia-water solution the theoretical analysis and calculations on two combination ways by adding the compressor in the high-pressure area and in the low-pressure area are conducted respectively.The effects of several factors including the evaporation temperature Te heat-source temperature Th as well as the cooling water temperature Tw on the equivalent heat consumption in compression qCW heat consumption in absorption qG and the system coefficient of performance COP are analyzed under the two combination configurations.The results show that the effect of the equivalent heat consumption in compression on the COP is less than that of the heat consumption in absorption.Besides the compressor set in the high-pressure area uses more energy than that in the low-pressure area. Moreover the compressor in the low-pressure area is superior to that in the high-pressure area with respect to the COP. Under the given intermediate pressure there is an optimum heat-source temperature corresponding to the maximum COP of the AWA/CCR cycle.
基金supported by the National Natural Science Foundation of China (Grant Nos. 10765004 and 11065008)
文摘Based on electron transport theory, the performance of kx and kr filtered thermoelectric refrigerators with two resonances are studied in this paper. The performance characteristic curves between the cooling rate and the coefficient of performance are plotted by numerical calculation. It is shown that the maximum cooling rate of the thermoelectric refrigerator with two resonances increases but the maximum coefficient of performance decreases compared with those with one resonance. No matter which resonance mechanism is used (kx or kr filtered), the cooling rate and the performance coefficient of the kr filtered refrigerator are much better than those of the kx filtered one.
基金Project supported by the National Basic Research Program of China (Grant Nos G2001039302 and 2007CB307001)the Natural Science Foundation of Guangdong Province (Grant No 2003A1030405)the Natural Science Foundation of Guangzhou City,China (Grant No 1999-Z035-01)
文摘In this paper, the theoretical analysis and simulating calculation were conducted for a basic two-stage semiconductor thermoelectric module, which contains one thermocouple in the second stage and several thermocouples in the first stage. The study focused on the configuration of the two-stage semiconductor thermoelectric cooler, especially investigating the influences of some parameters, such as the current I1 of the first stage, the area A1 of every thermocouple and the number n of thermocouples in the first stage, on the cooling performance of the module. The obtained results of analysis indicate that changing the current I1 of the first stage, the area A1 of thermocouples and the number n of thermocouples in the first stage can improve the cooling performance of the module. These results can be used to optimize the configuration of the two-stage semiconductor thermoelectric module and provide guides for the design and application of thermoelectric cooler.
基金Project(hx2013-87)supported by the Qingdao Economic and Technology Development Zone Haier Water-Heater Co.Ltd.,China
文摘In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400-2600 r/min), ambient air temperature(2.4-17.8 ℃) and condenser water inlet temperature(30-50℃). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance(COP) and system primary energy ratio(PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 ℃ to 17.8 ℃, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 ℃ to 50 ℃. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature.
基金Supported by Major State Basic Research Development Program of China ("973" Program, No. 2009CB219907)the Program for Changjiang Scholars and Innovative Research Team in University (No. IRT0936)
文摘Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.
文摘In the present study,an attempt ismade to enhance the performance of heat pump by utilizing two types of nanofluids namely,copper and alumina nanofluids.These nanofluids were employed around the evaporator coil of the heat pump.The nanofluids were used to enhance the heat input to the system by means of providing an external jacket around the evaporator coil.Both the nanofluids were prepared in three volume fractions 1%,2%and 5%.Water was chosen as the base fluid.The performance of the heat pump was assessed by calculating the coefficient of performance of the system when it was operated with and without nanofluid jacket.A significant enhancement in the coefficient of performance was noticed when copper and alumina nanofluids were employed in the system.Also,the coefficient of performance was found to have a direct relationship with the tested volume fractions.For the highest volume fraction of 5%,the performance of the heat pump was found to enhance by 23%with alumina nanofluid,while for copper nanofluid,a very significant enhancement in performance by 72%was observed.Thus,utilizing of nanofluids in heat pumps can be very beneficial towards performance enhancement and the idea can also be extended to other thermal systems such as steam power plant,automobile radiator,industrial heat exchangers and refrigeration systems.
文摘Cooling in industrial production and refrigeration of perishable and</span><span style="font-size:10.0pt;font-family:""> non-</span><span style="font-size:10.0pt;font-family:""> </span><span style="font-size:10.0pt;font-family:"">perishable products is common practice throughout the world. Research studies have been conducted both experimentally and numerically to simulate Vapor Compression Refrigeration System (VCRS) and its performance respectively, however, experimental procedure often seems to be expensive and time-consuming to carry out due to the function of many variables. This study was therefore designed to numerically simulate the performance assessment of a nanoparticle enhanced VCRS. A numerical model of a vapor compression refrigeration system was developed using standard refrigeration equations on each of the major components of the refrigeration system such as compressor, evaporator, condenser and expansion valve. The model was then simulated on a MATLAB platform with a CoolProp installed packages via Python under two different simulation cases. In the first case, the mass fractions were varied for CuO,</span><span style="font-size:10.0pt;font-family:""> </span><span style="font-size:10.0pt;font-family:"">TiO<sub>2</sub> and Al<sub>2</sub>O<sub>3</sub> nanoparticles while their densities remained constant and a reversed condition was investigated for the second case. The results showed that both the refrigerating effect and the Coefficient Of Performance (COP) of the system increase as both the mass fraction and density of all the nanoparticles increases. It also shows that the compressor work decreases as both the mass fraction and density of all the nanoparticles were increased. On comparing the computational and numerical analysis results, the study established no significant difference in terms of COP and the use of nanoparticles were found to have improved the COP of the system.
文摘In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element.
基金National Natural Science Foundation ofChina(No.5 0 2 760 63 )
文摘With COP and dynamic characteristics in refrigeration cycle as criteria,a new metal hydride couple——LaNi 4.61 Mn 0.26 Al 0.13 /La 0.6 Y 0.4 Ni 4.8 Mn 0.2 was selected by establishing calculation procedure and metal hydride selection model.The experimental results show that the refigeration cycle of the selected couple is good in the performance.The recovered waste heat and refrigeration power from exhaust gas of several kinds of automobile are calculated by waste-heat formula,coefficient R Q and COP.Refrigeration cycle of the new couple can satisfy the air-conditioning requirement of truck and car and is not enough in passenger car,according to the respective cooling load.
基金Supported by the Key Technology R&D Program of Tianjin,China(No.11ZCKFGX21100)Tianjin New Coastal District "Ten Campaign" Major Science and Technology Project(No.2010-BK140009 and 2010-BK140002)+1 种基金National Basic Research Program of China("973" Program,No.2009CB219900)the Program for Changjiang Scholars and Innovative Research Team in University(No.IRT0936)
文摘A refrigerant mixture TJR02 was developed and the comparison experiment was performed on a singlestage vapor compression refrigeration system originally designed for R22.Experimental results show that TJR02 can be directly used in the system without modifying the original system or changing lubricant.By replacing R22 with TJR02,cooling rate gets faster and at least 20% of energy is saved.The actual detection in the standard test-bed verifies the experimental results and indicates that the adoption of TJR02 leads to greater efficiency and wider application.And the lower the refrigeratory temperature is,the more obvious the energy saving effects will be.
文摘The thermodynamic cycle for an adsorption system is presented inp-T diagram. In order to investigate the performance of the adsorption system, a lumped parameter transient model of the chiller is developed, in order to predict the behaviors of the adsorption chiller system and find the influence of working conditions on its operation. For the working process of the main components of the system, including adsorber, condenser and evaporator, the coupled unsteady equations were set up for each stage. The model was then solved using stable numerical methods from EES (equation engineering solver), and the performance of the adsorber and condenser/evaporator of the system was analyzed. The condensation, evaporation and adsorber temperature values as well as the adsorption ratio and desorption ratio were obtained as function of operating time. Also, the coefficient of performance was analyzed in function of the heat source temperature and the cooling source temperature.
基金supported by the National Natural Science Foundation of China(Grant Nos.42001059,52178340)the Natural Science Foundation of Hebei Province,China(Grant No.E2020210044)+1 种基金the Key Laboratory of Mechanical Behavior Evolution and Control of Traffic Engineering Structures in Hebei(Grant No.SZ 2022-03)the Overseas Expertise Introduction Project for Discipline Innovation("111 Project",Grant No.B21011).
文摘This study introduces a novel artificial heating technique aimed at addressing frost heave issues in embankments on frozen ground,offering a sustainable solution.Initial evaluations assessed various heating systems,including boilers,heat pumps,solar heaters,and electric heaters,focusing on their thermal performance and applicability.The study subsequently designed and implemented a direct-expansion ground source heat pump(DX-GSHP)system as the primary heat source for embankment warming.Rigorous testing confirmed the DX-GSHP system's ability to maintain a heat-supply temperature above 40℃ and a heat-absorption temperature below -3.5℃,effectively extracting geothermal energy for transfer to the topsoil layers.With a demonstrated coefficient of performance(COP)of 3.49,the DX-GSHP system not only proves its energy efficiency but also suggests a potential role in reducing the strain on electricity supply systems.Installation of DX-GSHPs,with heating capacities ranging from 1.0 to 2.0 kW and spaced at intervals of 2.0-4.0 m,provides a rapid thermal response to frost heave in singletrack railway embankments,thereby potentially mitigating frost-induced damage in cold climate regions.
文摘The use of air conditioning and refrigeration systems improved the standard of living. However, the system contributes to global warming by releasing potential global warming refrigerants directly and powering the system. There is an obligation, like UN Kyoto Protocol, EU MAC Directive and Japan METI Directive to find an alternative low-GWP refrigerant with excellent thermophysical properties. In this paper, the global warming effect of an air-conditioning system is analyzed theoretically using few low-GWP refrigerant mixtures. New refrigerant mixtures are formed based on low GWP, high volumetric capacity, and refrigerating effect. After analyzing, refrigerant blends of R1234yf/R32 (40/60, 50/50, and 60/40 by wt%) and R1234ze/R32 (40/60, 50/50, and 60/40 by wt%) are found promising to replace the widely used R410A. The best performance of the refrigerant blend is found for R1234yf/R32 (40/60). These analyses are crucial for selecting suitable refrigerants for domestic air conditioning systems.
基金the research was sponsored by the Natural Science Foundation of Shandong Province(Grant No.ZR2022ME102)the Plan of Introduction and Cultivation for Young Innovative Talents in Colleges and Universities of Shandong Province(2021)+2 种基金the Scientific and Technological Innovation Project for Youth of Shandong Provincial Colleges and Universities(Grant No.2019KJH012)the Research on the Development of Intelligent Management System and Energy Saving Technology for Public Hospital Building Energy Use(Grant No.GYZ2022HQ44)Shandong Province Science and Technology Small and Medium Enterprises Innovation Ability Enhancement Project(Grant No.2023TSGC0052,2023TSGC0074).
文摘R134a-DMF absorption heat pump unit is an energy-saving heat pump unit that can utilize renewable energy,and has great potential in the refrigeration and heating fields of urban and rural areas.The purpose of this article is to conduct in-depth research on the dynamic characteristics of absorption heat pump units based on R134a-DMF,a new working fluid pair.A mathematical model of the thermophysical properties of the R134a-DMF working fluid pair and the mathematical models of various components of the heat pump unit are constructed.This paper constructs a simulation program,and uses the Control variates to study the change trend of the Coefficient of performance of R134a-DMF absorption heat pump unit affected by the generator outlet concentrated solution temperature,condenser air volume and temperature rise,and chilled water outlet temperature.The results indicate that the established mathematical model for thermophysical properties and the unit model are both accurate models,which can provide guidance for the actual operation and optimization of R134a-DMF absorption heat pump units.Through simulation,it can be concluded that for the three combined forms of R134a DMF(3:2),R134a DMF(1:1),and R134a DMF(2:3),the average increase in COP and refrigeration capacity is 0.85%,0.39%,and 0.42%for each 1℃ increase in the outlet concentrated solution temperature of the generator,respectively,and the growth rate is relatively slow.The larger the proportion of refrigerant in the binary solution,the greater the COP of the unit under the same operating conditions.
基金The National Natural Science Foundation of China(No.50776016)the National Key Technology R&D Program of China during the 11th Five-Year Plan Period(No.2008BAJ12B02)
文摘A solution cooling absorption(SCA)approach is proposed to modify the aqueous ammonia absorption refrigerat-ion cycle using the strong solution from the absorber to cool the forepart of the absorption in the cycle for reclaiming some portion of absorption heat.As a consequence of raised temperature at the inlet,the strong solution partially boils at the outlet of the solution heat exchanger,and diminishes the thermal heat consumption of the heat source.The calculation results show that the coefficient of performance(COP)of this modified cycle is about 28.3% higher than that of the traditional cycle under typical conditions;while the required heat transfer area of the total heat exchangers of the cycle is somewhat less than that of the traditional one.The capacity of refrigeration with the new absorption cycle is more than doubled in contrast to the adsorption scheme with an identical configuration.It is sufficient to supply a fishing boat the chilling capacity for preservation of fishing products with the modified cycle chiller driven by its diesel engine exhaust.