期刊文献+
共找到2,044篇文章
< 1 2 103 >
每页显示 20 50 100
Heat Transfer Area Optimization for Heat Exchanger System
1
作者 Yu-Cheng Liao Fu-I Chou +1 位作者 Po-Yuan Yang Jyh-Horng Chou 《Computer Modeling in Engineering & Sciences》 2025年第4期335-349,共15页
This paper presents an allowable-tolerance-based group search optimization(AT-GSO),which combines the robust GSO(R-GSO)and the external quality design planning of the Taguchi method.AT-GSO algorithm is used to optimiz... This paper presents an allowable-tolerance-based group search optimization(AT-GSO),which combines the robust GSO(R-GSO)and the external quality design planning of the Taguchi method.AT-GSO algorithm is used to optimize the heat transfer area of the heat exchanger system.The R-GSO algorithm integrates the GSO algorithm with the Taguchi method,utilizing the Taguchi method to determine the optimal producer in each iteration of the GSO algorithm to strengthen the robustness of the search process and the ability to find the global optima.In conventional parameter design optimization,it is typically assumed that the designed parameters can be applied accurately and consistently throughout usage.However,for systems that are sensitive to changes in design parameters,even minor inaccuracies can substantially reduce overall system performance.Therefore,the permissible variations of the design parameters are considered in the tolerance-optimized design to ensure the robustness of the performance.The optimized design of the heat exchanger system assumes that the system’s operating temperature parameters are specific.However,fixing the systemoperating temperature parameters at a constant value is difficult.This paper assumes that the system operating temperature parameters have an uncertainty error when optimizing the heat transfer area of the heat exchanger system.Experimental results show that the AT-GSO algorithm optimizes the heat exchanger system and finds the optimal operating temperature in the absence of tolerance and under three tolerance conditions. 展开更多
关键词 Heat exchanger system allowable tolerance-based group search optimization Taguchi method tolerance design
在线阅读 下载PDF
Synthesis of a novel pharmaceutical excipient: An anion exchange resin
2
作者 Zhannuan Yin Xianghuan Meng +5 位作者 Yingshu Feng Ke Li Xinyi Tang Hongfei Liu Haibing He Wei Mi 《Journal of Chinese Pharmaceutical Sciences》 2025年第2期109-125,共17页
The aim of this study was to develop a novel pharmaceutical excipient:an anion exchange resin.Initially,polystyrenedivinylbenzene(PS-DVB)microspheres were synthesized via suspension polymerization.Subsequently,these m... The aim of this study was to develop a novel pharmaceutical excipient:an anion exchange resin.Initially,polystyrenedivinylbenzene(PS-DVB)microspheres were synthesized via suspension polymerization.Subsequently,these microspheres served as a substrate for chloromethylation using methanol,formaldehyde,and chlorosulfonic acid.By optimizing the reaction conditions,the chloromethylated microspheres were characterized using infrared spectroscopy,scanning electron microscopy,and the Mohr method.Under optimal reaction conditions,the resulting products exhibited uniformity and spherical morphology,with an average particle size of approximately 190μm.The PS-DVB microspheres effectively incorporated chloromethyl groups,as evidenced by a chlorine content of 14.67%.Scanning electron microscopy analysis indicated that the appearance of the microspheres remained largely unchanged post-reaction.Overall,the research findings demonstrated the successful preparation of the anion exchange resin.Characterization and quality assessment confirmed that the ion exchange resin met the required standards. 展开更多
关键词 Suspension polymerization reaction POLYSTYRENE-DIVINYLBENZENE Quaternarization reaction Anion exchange resin Fluidized bed coating method Pharmacokinetic research
原文传递
Synthesis of flexible inter-plant heat exchanger networks:A decomposition method considering intermedium fluid circles
3
作者 Ran Tao Siwen Gu +1 位作者 Linlin Liu Jian Du 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第11期62-73,共12页
The traditional methods for synthesizing flexible heat exchanger networks(HENs)are not directly applicable to inter-plant HEN challenges,primarily due to the spread of system uncertainty across plants via intermedium ... The traditional methods for synthesizing flexible heat exchanger networks(HENs)are not directly applicable to inter-plant HEN challenges,primarily due to the spread of system uncertainty across plants via intermedium fluid circles.This complicates the synthesis process significantly.To tackle this issue,this study proposes a decomposed stepwise methodology to facilitate the flexible synthesis of the interplant HENs performing indirect heat integration.A decomposition strategy is proposed to divide the overall network into manageable sub-networks by dissecting the intermedium fluid circles.To address the variability in intermedium fluid temperatures,a temperature fluctuation analysis approach is developed and a heuristic rule is introduced to maintain the temperature feasibility of the intermedium fluids.To ensure adequate flexibility and cost-effectiveness of the designed networks,flexibility analysis and network retrofit steps are conducted through model-based optimization techniques.The efficacy of the method is demonstrated through two case studies,showing its potential in achieving the desired operational flexibility for inter-plant HENs. 展开更多
关键词 Inter-plant heat exchanger networks(HENs) Indirect heat integration Flexible synthesis Flexible analysis Decomposition method
在线阅读 下载PDF
Revealing the catalytic mechanism of an ionic liquid with an isotope exchange method 被引量:3
4
作者 Sun Xuewen Zhao Suoqi 《Petroleum Science》 SCIE CAS CSCD 2011年第4期495-501,共7页
The alkylation mechanism catalyzed by an ionic liquid (as a Lewis acid) may be different from the traditional alkylation mechanism catalyzed by Br nsted acid,especially as their initiation steps are still not clear.... The alkylation mechanism catalyzed by an ionic liquid (as a Lewis acid) may be different from the traditional alkylation mechanism catalyzed by Br nsted acid,especially as their initiation steps are still not clear.In this paper,an isotope exchange method is used to investigate the catalytic mechanism of AlCl 3 /butyl-methyl-imidazolium chloride ionic liquid in the alkylation of benzene with 1-dodecene.The proposed catalytic mechanism was confirmed by analysis of ionic liquid before and after reaction and of the alkylation products of deuterated benzene (C 6 D 6) with 1-dodecene.The proposed mechanism consists of the equilibrium reaction between [Al 2 Cl 7 ] +H + and [AlHCl 3 ] + +[AlCl 4 ],in which the Br nsted acid [AlHCl 3 ] + is supplied by the reaction of 2-H on the imidazolium ring and [Al 2 Cl 7 ].The alkylation reaction is initiated by the Br nsted acid [AlHCl 3 ] + which reacts with 1-dodecene to form a carbonium ion,then the carbonium ion reacts with benzene to form an unstable σ complex,leading to the formation of 2-phenyldodecane. 展开更多
关键词 Catalytic mechanism ionic liquid isotope exchange method ALKYLATION deuterated benzene
原文传递
Calculation Method of Passive Residual Heat Removal Heat Exchanger and Numerical Simulation 被引量:1
5
作者 Qiming Men Xuesheng Wang +1 位作者 Xiang Zhou Xiangyu Meng 《Journal of Power and Energy Engineering》 2014年第9期8-14,共7页
The tube inside and outside heat transfer mechanism of Passive Residual Heat Removal Heat Exchanger (PRHR HX) was analyzed. The calculation method of this special heat exchanger under natural convection condition in I... The tube inside and outside heat transfer mechanism of Passive Residual Heat Removal Heat Exchanger (PRHR HX) was analyzed. The calculation method of this special heat exchanger under natural convection condition in In-containment Refueling Water Storage Tank (IRWST) was carried out. The single-tube coupling model three-dimensional natural circulation in the IRWST was simulated numerically using Fluent. The heat transfer and flow characteristics of the fluid in IRWST were obtained. The comparison of the results between theoretical arithmetic and numerical simulation showed that the theoretical calculation method is suitable for the heat transfer calculation of PRHR HX. 展开更多
关键词 PASSIVE RESIDUAL HEAT Removal HEAT exchangeR HEAT Transfer Calculation method Numerical Simulation Natural CONVECTION
在线阅读 下载PDF
Delaware Method Improvement for the Shell and Tubes Heat Exchanger Design 被引量:1
6
作者 Miguel Toledo-Velázquez Pedro Quinto-Diez +3 位作者 Juan C. Alzelmetti-Zaragoza Sergio R. Galvan Juan Abugaber-Francis Arturo Reyes-León 《Engineering(科研)》 2014年第4期193-201,共9页
In this paper the Delaware Method published in 1963 is analyzed and upgraded with using correction factors which take into account the undesirable currents of the mean flow. However, this method presents graphically t... In this paper the Delaware Method published in 1963 is analyzed and upgraded with using correction factors which take into account the undesirable currents of the mean flow. However, this method presents graphically these correction factors which imply an impediment to fulfill the software calculations. Thus, the equations corresponding to the correction factor equations and a Fortran 77 numerical program were established. This system is given to explore different design alternatives in order to find the optimal solution to each proposed problem. The results of this work was a simple software that can perform calculations with the introduction of parameters depending only on the geometry of the heat exchanger, i.e., geometry, temperature and fluid characteristics eliminating the human errors and increasing the calculations speed and accuracy. 展开更多
关键词 DELAWARE method Flow CORRECTION FACTOR HEAT exchangeR
暂未订购
ELECTRIC REGENERATION METHOD OF IONEXCHANGE RESIN IN THE MIXED BED 被引量:2
7
作者 Wang Fang 《Chinese Journal of Reactive Polymers》 1998年第2期68-74,共7页
In this paper the self-regeneration process of the mixed resins consisting of cationand anion ion exchangers in the electrolialyser of the packed bed is analyzed and anelectric regeneration method is put forward to su... In this paper the self-regeneration process of the mixed resins consisting of cationand anion ion exchangers in the electrolialyser of the packed bed is analyzed and anelectric regeneration method is put forward to supply the desalinated water by mixedbed The electric regeneration technology is a new one used for regeneration of theexhausted ion exchangers in the mixed bed instead of the traditional regeneratingprocess by using acid and abc liquor Electric energy is consumed to regenerat theion exchangers loaded by salts from water treatment without any chemicals- acid alkali. The advantage of the electric regeneration process edibited convenientoperation, no discharge any waste, and therefore no Polluted to the recehang waterbode and the environmental ground 展开更多
关键词 Electric regeneration method of ion exchange resin Membranetechnology Pollution control
在线阅读 下载PDF
Modeling hydrogen exchange of proteins by a multiscale method
8
作者 Wentao Zhu Wenfei Li Wei Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第7期93-99,共7页
We proposed a practical way for mapping the results of coarse-grained molecular simulations to the observables in hydrogen change experiments.By combining an atomic-interaction based coarse-grained model with an all-a... We proposed a practical way for mapping the results of coarse-grained molecular simulations to the observables in hydrogen change experiments.By combining an atomic-interaction based coarse-grained model with an all-atom structure reconstruction algorithm,we reproduced the experimental hydrogen exchange data with reasonable accuracy using molecular dynamics simulations.We also showed that the coarse-grained model can be further improved by imposing experimental restraints from hydrogen exchange data via an iterative optimization strategy.These results suggest that it is feasible to develop an integrative molecular simulation scheme by incorporating the hydrogen exchange data into the coarse-grained molecular dynamics simulations and therefore help to overcome the accuracy bottleneck of coarse-grained models. 展开更多
关键词 coarse-grained model hydrogen exchange multiscale method PROTEINS integrative molecular simulations
原文传递
FMLSMETHODOFPARAMETERESTIMATIONANDITSAPPLICATIONTOHEAT┐EXCHANGERIDENTIFICATION
9
作者 Zhou Bo Tu Zhiying Department of Automatic Control, NUAA29 Yudao Street, Nanjing 210016, P. R. China Chongqing University, Chongqing 630044,P.R.China) 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1996年第1期87-94,共8页
Using the inversion of the auto correlation function Toeplitz matrix of pseudo random binary sequence (PRBS) derived in this paper and the theorem of partitioned matrix inversion, a fast multistage least squares (FM... Using the inversion of the auto correlation function Toeplitz matrix of pseudo random binary sequence (PRBS) derived in this paper and the theorem of partitioned matrix inversion, a fast multistage least squares (FMLS) method is developed. Its performances are theoretically analyzed and digital simulation is made to compare FMLS with multistage least squares (MSLS), correlation least squares(COR LS) and LS for their computer speed and identification accuracy. Finally, FMLS is applied to identifying the heat excharger dynamics. It is shown that FMLS is a good and effective identification technique. 展开更多
关键词 systems identification least squares methods parameter estimations fast multistage least squares heat exchanger
在线阅读 下载PDF
A Pole Assignment Design Method of Process Control System for Tubular Heat Exchanger
10
作者 周清泉 《Chinese Quarterly Journal of Mathematics》 CSCD 1992年第4期13-19,共7页
This Paper has first studied the simplified model of tubular heat exchanger which is widely used in the industry and other field.On the basis of reference 2,a new pole assignment design method of pro-cess control syst... This Paper has first studied the simplified model of tubular heat exchanger which is widely used in the industry and other field.On the basis of reference 2,a new pole assignment design method of pro-cess control system with derivative control action is found.For the above system,the method and the for-mation which calculate the feedback matrix K and gain matrix L is given,and the simulation of the system is made. 展开更多
关键词 tubular heat exchanger process control system pole assignment design method feedback matrix Gain matrix
在线阅读 下载PDF
Efficiency and Effectiveness Method versus ε-NTU Method with Application in Finned Flat Tube Compact Heat Exchanger with Water-Ethylene Glycol as Nanofluid Base of Iron Oxide Nanoparticles
11
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2022年第2期1-17,共17页
This work aims to establish comparisons between two models used for the performance of heat exchangers. The chosen system, in this case, consists of a heat exchanger used in automotive radiators flat finned tube type.... This work aims to establish comparisons between two models used for the performance of heat exchangers. The chosen system, in this case, consists of a heat exchanger used in automotive radiators flat finned tube type. Water and ethylene glycol compound as base fluid and volume fractions of iron oxide nanoparticles (Fe<sub>3</sub>O<sub>4</sub>) are used as a refrigerant. The quantities determined in this work are the nanofluid exit temperature, the air exit temperature, the absolute error between the models for heat transfer rate, and Effectiveness. The quantities that constitute parameters, independent variables, are the airflow, represented by the Reynolds number, and the iron oxide volume fraction. Ethylene Glycol 50% compound has slightly better thermal performance than pure water and reduces the reactive effect of water on the environment, increasing the average life of the equipment. The absolute relative error between the models is less than 20% and presents maximum values with the increase of the nanoparticle volume fraction and growth in the Reynolds number for the air. 展开更多
关键词 Efficiency and Effectiveness method ε-NTU method Compact Heat exchanger Iron Oxid Nanoparticles NANOFLUID
在线阅读 下载PDF
Comparison of Highly-Weathered Acid Soil CEC Determined by NH<sub>4</sub>OAc (pH = 7.0) Exchange Method and BaCl<sub>2</sub>-MgSO<sub>4</sub>Forced-Exchange Method
12
作者 Xiangzheng Kong Decheng Li +1 位作者 Xiaodong Song Ganlin Zhang 《Agricultural Sciences》 2021年第9期917-927,共11页
Cation exchange capacity (CEC) is one of the most important properties of soils. The NH<sub>4</sub>OAc (pH = 7.0) exchange method is usually recommended to determine CEC (CEC<sub>1</sub>) of al... Cation exchange capacity (CEC) is one of the most important properties of soils. The NH<sub>4</sub>OAc (pH = 7.0) exchange method is usually recommended to determine CEC (CEC<sub>1</sub>) of all soils with different pH values, particularly for studies on soil taxonomy. But comparatively the BaCl<sub>2</sub>-MgSO<sub>4</sub> forced-exchange method is more authentic in determining CEC (CEC<sub>2</sub>) of tropical and subtropical highly-weathered acid soils. But so far little is known about the difference between CEC<sub>1</sub> and CEC<sub>2</sub>. In this study, the physiochemical data of 114 acid B horizon soils from 112 soil series of tropical and subtropical China were used, CEC<sub>1</sub> and CEC<sub>2</sub> were determined and compared, the influencing factors were analyzed for the difference between CEC<sub>1</sub> and CEC<sub>2</sub>, and then a regression model was established between CEC<sub>1</sub> and CEC<sub>2</sub>. The results showed that CEC<sub>2</sub> was significantly lower than CEC<sub>1</sub> (p < 0.01), CEC<sub>2</sub> was 14.76% - 63.31% with a mean of 36.32% of CEC<sub>1</sub>. In view of the contribution to CEC from other properties, CEC<sub>2</sub> was mainly determined by pH (45.92%), followed by silt (21.05%), free Fe<sub>2</sub>O<sub>3</sub> (17.35%) and clay contents (12.76%), CEC<sub>1</sub> was mainly decided by free Fe<sub>2</sub>O<sub>3</sub> content (40.38%), followed by pH (28.39%) and silt content (27.29%;and the difference between CEC<sub>1</sub> and CEC<sub>2</sub> was mainly affected by free Fe<sub>2</sub>O<sub>3</sub> (50.92%), followed by silt content (26.46%) and pH (21.80%). The acceptable optimal regression model between CEC<sub>2</sub> and CEC<sub>1</sub> was established as CEC<sub>2</sub> = 2.3114 × CEC<sub>1</sub><sup>1.1496</sup> (R<sup>2</sup> = 0.410, P < 0.001, RMSE = 0.15). For the studies on soil taxonomy, the BaCl<sub>2</sub>-MgSO<sub>4</sub> forced-exchange method is recommended in determining CEC of the highly-weathered acid soils in the tropical and subtropical regions. 展开更多
关键词 Acid Soil CEC Determination NH4OAc (pH = 7.0) exchange method BaCl2-MgSO4 Forced-exchange method
在线阅读 下载PDF
On The Translation Principles and Methods in the Jingdezhen Ceramic Cultural Exchanges with the Outside World
13
作者 Shuwu Cheng Yu Fang 《Journal of Zhouyi Research》 2014年第2期30-32,共3页
关键词 景德镇陶瓷 文化交流 翻译 陶瓷文化 对外交流 直译
在线阅读 下载PDF
Estimating spatial pattern of hyporheic water exchange in slack water pool 被引量:6
14
作者 SONG Jinxi CHENG Dandong +4 位作者 ZHANG Junlong ZHANG Yongqiang LONG Yongqing ZHANG Yan SHEN Weibo 《Journal of Geographical Sciences》 SCIE CSCD 2019年第3期377-388,共12页
Hyporheic zone(HZ) influences hydraulic and biogeochemical processes in and alongside streams, therefore, investigating the controlling geographic factors is beneficial for understanding the hydrological processes in ... Hyporheic zone(HZ) influences hydraulic and biogeochemical processes in and alongside streams, therefore, investigating the controlling geographic factors is beneficial for understanding the hydrological processes in HZ. Slack water pool (SWP) is an essential micro-topographic structure that has an impact on surface water and groundwater interactions in the HZ during and after high flows. However, only a few studies investigate HZ surface water and groundwater exchange in the SWP. This study used the thermal method to estimate the HZ water exchange in the SWP in a segment of the Weihe River in China during the winter season. The findings show that on the flow-direction parallel to the stream, river recharge dominates the HZ water exchange, while on the opposing flow-direction bank groundwater discharge dominates the water exchange. The water exchange in the opposing flow-direction bank is about 1.6 times of that in the flow-direction bank. The HZ water exchange is not only controlled by flow velocity but also the location and shape of the SWP. Great water exchange amount corresponds to the shape with more deformation. The maximum water exchange within the SWP is close to the river bank where the edge is relatively high. This study provides some guidelines for water resources management during flooding events. 展开更多
关键词 HYPORHEIC WATER exchange thermal method discharge RECHARGE surface water-groundwater interactions
原文传递
Total Heat Exchange Factor Based on Non-Gray Radiation Properties of Gas in Reheating Furnace 被引量:4
15
作者 CUI Miao CHEN Hai-geng XU Li WU Bin 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2009年第3期27-31,63,共6页
Modified mathematical models based on imaginary plane zone method in reheating furnace were developed in which non-gray radiation properties of gas were considered,and the Newton's method and the finite difference me... Modified mathematical models based on imaginary plane zone method in reheating furnace were developed in which non-gray radiation properties of gas were considered,and the Newton's method and the finite difference method were adopted. Effects of productivity,fuel consumption,fuel-air ratio,calorific value of fuel and inserting depth of thermocouple on total heat exchange factor along the length of reheating furnace were investigated. The results show that total heat exchange factor increases with productivity or inserting depth of thermocouple,and it decreases when fuel consumption,fuel-air ratio or calorific value of fuel increases. The results are valuable for dynamical compensation of total heat exchange factor for online control mathematical models in reheating furnace. 展开更多
关键词 imaginary plane zone method non-gray radiation property total heat exchange factor dynamical compensation
原文传递
Measurement of air exchange rates in different indoor environments using continuous CO_2 sensors 被引量:2
16
作者 Yan You Can Niu +5 位作者 Jian Zhou Yating Liu Zhipeng Bai Jiefeng Zhang Fei He Nan Zhang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2012年第4期657-664,共8页
A new air exchange rate (AER) monitoring method using continuous CO2 sensors was developed and validated through both laboratory experiments and field studies. Controlled laboratory simulation tests were conducted i... A new air exchange rate (AER) monitoring method using continuous CO2 sensors was developed and validated through both laboratory experiments and field studies. Controlled laboratory simulation tests were conducted in a 1-m3 environmental chamber at different AERs (0.1-10.0 hr-1). AERs were determined using the decay method based on box model assumptions. Field tests were conducted in classrooms, dormitories, meeting rooms and apartments during 2-5 weekdays using CO2 sensors coupled with data loggers. Indoor temperature, relative humidity (RH), and CO2 concentrations were continuously monitored while outdoor parameters combined with on-site climate conditions were recorded. Statistical results indicated that good laboratory performance was achieved: duplicate precision was within 10%, and the measured AERs were 90%-120% of the real AERs. Average AERs were 1.22, 1.37, 1.10, 1.91 and 0.73 hr-l in dormitories, air-conditioned classrooms, classrooms with an air circulation cooling system, reading rooms, and meeting rooms, respectively. In an elderly particulate matter exposure study, all the homes had AER values ranging from 0.29 to 3.46 hr-1 in fall, and 0.12 to 1.39 hr-1 in winter with a median AER of 1.15. 展开更多
关键词 air exchange rate continuous CO2 sensor steady-state method decay method particulate matter indoor-outdoorconcentration relationship
原文传递
Carbon-supported ultrafine Pt nanoparticles modified with trace amounts of cobalt as enhanced oxygen reduction reaction catalysts for proton exchange membrane fuel cells 被引量:7
17
作者 Xuejun Tang Dahui Fang +6 位作者 Lijuan Qu Dongyan Xu Xiaoping Qin Bowen Qin Wei Song Zhigang Shao Baolian Yi 《Chinese Journal of Catalysis》 SCIE EI CAS CSCD 北大核心 2019年第4期504-514,M0002,共12页
To accelerate the kinetics of the oxygen reduction reaction(ORR)in proton exchange membrane fuel cells,ultrafine Pt nanoparticles modified with trace amounts of cobalt were fabricated and decorated on carbon black thr... To accelerate the kinetics of the oxygen reduction reaction(ORR)in proton exchange membrane fuel cells,ultrafine Pt nanoparticles modified with trace amounts of cobalt were fabricated and decorated on carbon black through a strategy involving modified glycol reduction and chemical etching.The obtained Pt36Co/C catalyst exhibits a much larger electrochemical surface area(ECSA)and an improved ORR electrocatalytic activity compared to commercial Pt/C.Moreover,an electrode prepared with Pt36Co/C was further evaluated under H2-air single cell test conditions,and exhibited a maximum specific power density of 10.27 W mgPt^-1,which is 1.61 times higher than that of a conventional Pt/C electrode and also competitive with most state-of-the-art Pt-based architectures.In addition,the changes in ECSA,power density,and reacting resistance during the accelerated degradation process further demonstrate the enhanced durability of the Pt36Co/C electrode.The superior performance observed in this work can be attributed to the synergy between the ultrasmall size and homogeneous distribution of catalyst nanoparticles,bimetallic ligand and electronic effects,and the dissolution of unstable Co with the rearrangement of surface structure brought about by acid etching.Furthermore,the accessible raw materials and simplified operating procedures involved in the fabrication process would result in great cost-effectiveness for practical applications of PEMFCs. 展开更多
关键词 Proton exchange membrane fuel cells Oxygen reduction reaction Ultrafine Pt nanoparticles Trace amounts of cobalt Modified glycol method Chemical etching strategy
在线阅读 下载PDF
Modelling of graded index waveguide fabricated by ion exchange on Er^(3+) doped glass 被引量:1
18
作者 邵公望 金国良 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第3期1096-1104,共9页
A general numerical tool, based on thermal diffusion equation and full-vectorial eigen-mode equation, has been presented for the systematic analysis of graded index channel waveguide fabricated by ion exchange on Er^3... A general numerical tool, based on thermal diffusion equation and full-vectorial eigen-mode equation, has been presented for the systematic analysis of graded index channel waveguide fabricated by ion exchange on Er^3+ doped glass. Finite difference method with full-vectorial formulation (FV-FDM) is applied to solving the full-vectorial modes of graded index channel waveguide for the first time. The coupled difference equations based on magnetic fields in FV-FDM are derived from the Taylor series expansion and accurate formulation of boundary conditions. Hybrid nature of vectorial guided modes for both pump (980 nm) and signal light (1550 nm) are demonstrated by the simulation. Results show that the fabrication parameters of ion exchange, such as channel opening width and time ratio of second step to first step in ion exchange, have large influence on the properties of waveguide. By optimizing the fabrication parameters, maintenance of monomode for signal light and improvement of the gain dynamics can be achieved in Er^3+ doped waveguide amplifier (EDWA) fabricated by ion exchange technique. This theoretical model is significant for the design and fabrication of EDWA with ion exchange technique. Furthermore, a single polarization EDWA, which operates at wavelength from 1528 nm to 1541 nm for HE polarization, is numerically designed. 展开更多
关键词 graded index channel waveguide finite difference method full-vectorial mode ion exchange technique
原文传递
Stability and weighted sensitivity analysis of robust controller for heat exchanger 被引量:2
19
作者 Sapna GUPTA Rajeev GUPTA Subhransu PADHEE 《Control Theory and Technology》 EI CSCD 2020年第1期56-71,共16页
This study presents a parametric system identification approach to estimate the dynamics of a chemical plant from experimental data and develops a robust PID controller for the plant.Parametric system identification o... This study presents a parametric system identification approach to estimate the dynamics of a chemical plant from experimental data and develops a robust PID controller for the plant.Parametric system identification of the heat exchanger system has been carried out using experimental data and prediction error method.The estimated model of the heat exchanger system is a time-delay model and a robust PID controller for the time-delayed model has been designed considering weighted sensitivity criteria.The mathematical background of parametric system identification,stability analysis,and H∞ weighted sensitivity analysis have been provided in this paper.A graphical plot has been provided to determine the stability region in the(Kp,Ki),(Kp,Kd)and(KuKd)plane.The stability region is a locus dependent on parameters of the controller and frequency,in the parameter plane. 展开更多
关键词 Heat exchangeR PARAMETRIC system identification prediction error method PID controller robust STABILITY ANALYSIS WEIGHTED sensitivity ANALYSIS
原文传递
Theoretical Investigation of Exchange Bias in Compensated Cases 被引量:1
20
作者 XIONG Zhi-Jie WANG Huai-Yu DING Ze-Jun 《Communications in Theoretical Physics》 SCIE CAS CSCD 2008年第11期1241-1244,共4页
The exchange bias (EB) of the ferromagnetic (FM)/antiferromagnetic (AFM) bilayers in a compensated case is studied by use of the many-body Green's function method of quantum statistical theory. The so-called co... The exchange bias (EB) of the ferromagnetic (FM)/antiferromagnetic (AFM) bilayers in a compensated case is studied by use of the many-body Green's function method of quantum statistical theory. The so-called compensated case is that there is no net magnetization on the AFM side of the interface. Our conclusion is that the EB in this case is primarily from the asymmetry of the interracial exchange coupling strengths between the FM and the two sublattices of the AFM. The effects of the layer thickness, temperature and the interracial coupling strength oi2 the exchange bias HE are investigated. The dependence of HE on the FM layer thickness and temperature is qualitatively in agreement with experimental results. HE is nearly inversely proportional to FM thickness. When temperature varies, both HE and He decrease with temperature increasing. The anisotropy of the FM layer only slightly influence He, but does not influence HE. 展开更多
关键词 exchange bias COERCIVITY compensated case Heisenberg Hamiltonian the many-body Green's function method
在线阅读 下载PDF
上一页 1 2 103 下一页 到第
使用帮助 返回顶部