Ensuring the reliability of power systems in microgrids is critical,particularly under contingency conditions that can disrupt power flow and system stability.This study investigates the application of Security-Constr...Ensuring the reliability of power systems in microgrids is critical,particularly under contingency conditions that can disrupt power flow and system stability.This study investigates the application of Security-Constrained Optimal Power Flow(SCOPF)using the Line Outage Distribution Factor(LODF)to enhance resilience in a renewable energy-integrated microgrid.The research examines a 30-bus system with 14 generators and an 8669 MW load demand,optimizing both single-objective and multi-objective scenarios.The single-objective opti-mization achieves a total generation cost of$47,738,while the multi-objective approach reduces costs to$47,614 and minimizes battery power output to 165.02 kW.Under contingency conditions,failures in transmission lines 1,22,and 35 lead to complete power loss in those lines,requiring a redistribution strategy.Implementing SCOPF mitigates these disruptions by adjusting power flows,ensuring no line exceeds its capacity.Specifically,in contingency 1,power in channel 4 is reduced from 59 to 32 kW,while overall load shedding is minimized to 0.278 MW.These results demonstrate the effectiveness of SCOPF in maintaining stability and reducing economic losses.Unlike prior studies,this work integrates LODF into SCOPF for large-scale microgrid applications,offering a computationally efficient contingency management framework that enhances grid resilience and supports renewable energy adoption.展开更多
Due to the climate-dependent nature of renewable energy sources(RESs),solving the optimal power flow(OPF)problem in power systems that integrate RESs,such as photovoltaic(PV)units and wind turbines(WTs),remains a sign...Due to the climate-dependent nature of renewable energy sources(RESs),solving the optimal power flow(OPF)problem in power systems that integrate RESs,such as photovoltaic(PV)units and wind turbines(WTs),remains a significant challenge.To address this problem,this study presents an effective framework that incorporates solar and wind power generation.To manage the nonconvex and nonlinear characteristics of the OPF problem,a modified physics-inspired algorithm termed the Enhanced Coulomb’s and Franklin’s laws Algorithm(ECFA),is deployed.In the proposed OPF model,the power generated from RESs is considered a dependent variable,while voltages at buses equipped with RESs serve as decision variables.Real-time data on solar irradiation and wind speed are used to model the power outputs of PV units and WTs,respectively.Although the Coulomb’s and Franklin’s law algorithm(CFA)offers some advantages,it underperforms on complex optimization tasks compared to SSA,BA,SCA,ABC,and CFA.The enhanced version of the CFA improves the search process across the feasible space by incorporating diverse interaction methods and enhancing exploitation capabilities.The performance of the proposed ECFA is assessed through comprehensive comparisons with state-of-the-art methods for solving the OPF problem.展开更多
In order to increase the productivity of microreactors, the parallelization of the microreactors is required. The performances of flow distributors can affect the product yield and fault detection ability when blockag...In order to increase the productivity of microreactors, the parallelization of the microreactors is required. The performances of flow distributors can affect the product yield and fault detection ability when blockage happens.In this research, an optimal design method to calculate the channel diameters and to determine the flow sensor location is derived based on mass balance and pressure balance models of split-and-recombine-type flow distributors(SRFDs). The model accuracy is verified by experiment data. The proposed method is applied to optimal design of SRFDs under constant flow rate operation conditions. The maximum angle difference between normal and blockage conditions at one sensor to those at the other sensors is set to be the objective function and the uniformity of flow distribution in microreactors under normal condition is also required. The diameters of each pipe in SRFDs are selected as the design variables. Simulated annealing algorithm is used to solve the optimization problem. The effectiveness of the optimal design results is demonstrated by fluid dynamics simulations. The results show that using the optimal channel diameters of SRFDs, the pressure drop in SRFD section is lower than that of the microreactor section. Meanwhile, in the case studies, only a few sensors that are located inside the SRFDs can easily detect the blockage abnormal condition in the parallelized microreactor system.展开更多
The artificial bee colony(ABC) algorithm is improved to construct a hybrid multi-objective ABC algorithm, called HMOABC, for resolving optimal power flow(OPF) problem by simultaneously optimizing three conflicting obj...The artificial bee colony(ABC) algorithm is improved to construct a hybrid multi-objective ABC algorithm, called HMOABC, for resolving optimal power flow(OPF) problem by simultaneously optimizing three conflicting objectives of OPF, instead of transforming multi-objective functions into a single objective function. The main idea of HMOABC is to extend original ABC algorithm to multi-objective and cooperative mode by combining the Pareto dominance and divide-and-conquer approach. HMOABC is then used in the 30-bus IEEE test system for solving the OPF problem considering the cost, loss, and emission impacts. The simulation results show that the HMOABC is superior to other algorithms in terms of optimization accuracy and computation robustness.展开更多
This paper proposes an efficient method for optimal power flow solution (OPF) using particle swarm optimization (PSO) technique. The objective of the proposed method is to find the steady state operation point in ...This paper proposes an efficient method for optimal power flow solution (OPF) using particle swarm optimization (PSO) technique. The objective of the proposed method is to find the steady state operation point in a power system which minimizes the fuel cost, while maintaining an acceptable system performance in terms of limits on generator power, line flow limits and voltage limits. In order to improvise the performance of the conventional PSO (cPSO), the fine tuning parameters- the inertia weight and acceleration coefficients are formulated in terms of global-local best values of the objective function. These global-local best inertia weight (GLBestlW) and global-local best acceleration coefficient (GLBestAC) are incorporated into PSO in order to compute the optimal power flow solution. The proposed method has been tested on the standard IEEE 30 bus test system to prove its efficacy. The results are compared with those obtained through cPSO. It is observed that the proposed algorithm is computationally faster, in terms of the number of load flows executed and provides better results than the conventional heuristic techniques.展开更多
The security constrained distributed optimal power flow (DOPF) of interconnected power systems is presented. The centralized OPF problem of the multi-area power systems is decomposed into independent DOPF subproblem...The security constrained distributed optimal power flow (DOPF) of interconnected power systems is presented. The centralized OPF problem of the multi-area power systems is decomposed into independent DOPF subproblems, one for each area. The dynamic security region (DSR) to guarantee the transient stability constraints and static voltage stability region (SVSR) constraints, and line current limits are included as constraints. The solutions to the DOPF subproblems of the different areas are coordinated through a pricing mechanism until they converge to the centralized OPF solution. The nonlinear DOPF subproblem is solved by predictor-corrector interior point method (PClPM). The IEEE three-area RTS-96 system is worked out in order to demonstrate the effectiveness of the proposed method.展开更多
In the contemporary era,the global expansion of electrical grids is propelled by various renewable energy sources(RESs).Efficient integration of stochastic RESs and optimal power flow(OPF)management are critical for n...In the contemporary era,the global expansion of electrical grids is propelled by various renewable energy sources(RESs).Efficient integration of stochastic RESs and optimal power flow(OPF)management are critical for network optimization.This study introduces an innovative solution,the Gaussian Bare-Bones Levy Cheetah Optimizer(GBBLCO),addressing OPF challenges in power generation systems with stochastic RESs.The primary objective is to minimize the total operating costs of RESs,considering four functions:overall operating costs,voltage deviation management,emissions reduction,voltage stability index(VSI)and power loss mitigation.Additionally,a carbon tax is included in the objective function to reduce carbon emissions.Thorough scrutiny,using modified IEEE 30-bus and IEEE 118-bus systems,validates GBBLCO’s superior performance in achieving optimal solutions.Simulation results demonstrate GBBLCO’s efficacy in six optimization scenarios:total cost with valve point effects,total cost with emission and carbon tax,total cost with prohibited operating zones,active power loss optimization,voltage deviation optimization and enhancing voltage stability index(VSI).GBBLCO outperforms conventional techniques in each scenario,showcasing rapid convergence and superior solution quality.Notably,GBBLCO navigates complexities introduced by valve point effects,adapts to environmental constraints,optimizes costs while considering prohibited operating zones,minimizes active power losses,and optimizes voltage deviation by enhancing the voltage stability index(VSI)effectively.This research significantly contributes to advancing OPF,emphasizing GBBLCO’s improved global search capabilities and ability to address challenges related to local minima.GBBLCO emerges as a versatile and robust optimization tool for diverse challenges in power systems,offering a promising solution for the evolving needs of renewable energy-integrated power grids.展开更多
This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or abs...This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or absorbed using the available capacity and the adjustable power factor of the inverter. The reduction of unbalance voltage and losses in the distribution systems is obtained by actions of reactive power control of the inverter. The TOPF is formulated by current balance equations and the PV systems are modeled via an equivalent circuit. The primal-dual interior point method is used to obtain the optimal operating points for the systems for different scenarios of solar irradiance and temperature, thus providing a detailed view of the impact of photovoltaic distributed generation.展开更多
This paper addresses the problem of reducing CO<sub>2</sub> emissions by applying convex optimal power flow model to the combined economic and emission dispatch problem. The large amount of CO<sub>2&...This paper addresses the problem of reducing CO<sub>2</sub> emissions by applying convex optimal power flow model to the combined economic and emission dispatch problem. The large amount of CO<sub>2</sub> emissions in the power industry is a major source of global warming effect. An efficient and economic approach to reduce CO<sub>2</sub> emissions is to formulate the emission reduction problem as emission dispatch problem and combined with power system economic dispatch (ED). Because the traditional optimal power flow (OPF) model used by the economic dispatch is nonlinear and nonconvex, current nonlinear solvers are not able to find the global optimal solutions. In this paper, we use the convex optimal power flow model to formulate the combined economic and emission dispatch problem. The advantage of using convex power flow model is that global optimal solutions can be obtained by using mature industrial strength nonlinear solvers such as MOSEK. Numerical results of various IEEE power network test cases confirm the feasibility and advantage of convex combined economic and emission dispatch (CCEED).展开更多
Firefly algorithm is the new intelligent algorithm used for all complex engineering optimization problems. Power system has many complex optimization problems one of which is the optimal power flow (OPF). Basically, i...Firefly algorithm is the new intelligent algorithm used for all complex engineering optimization problems. Power system has many complex optimization problems one of which is the optimal power flow (OPF). Basically, it is minimizing optimization problem and subjected to many complex objective functions and constraints. Hence, firefly algorithm is used to solve OPF in this paper. The aim of the firefly is to optimize the control variables, namely generated real power, voltage magnitude and tap setting of transformers. Flexible AC Transmission system (FACTS) devices may used in the power system to improve the quality of the power supply and to reduce the cost of the generation. FACTS devices are classified into series, shunt, shunt-series and series-series connected devices. Unified power flow controller (UPFC) is shunt-series type device that posses all capabilities to control real, reactive powers, voltage and reactance of the connected line in the power system. Hence, UPFC is included in the considered IEEE 30 bus for the OPF solution.展开更多
The Sine and Wormhole Energy Whale Optimization Algorithm(SWEWOA)represents an advanced solution method for resolving Optimal Power Flow(OPF)problems in power systems equipped with Flexible AC Transmission System(FACT...The Sine and Wormhole Energy Whale Optimization Algorithm(SWEWOA)represents an advanced solution method for resolving Optimal Power Flow(OPF)problems in power systems equipped with Flexible AC Transmission System(FACTS)devices which include Thyristor-Controlled Series Compensator(TCSC),Thyristor-Controlled Phase Shifter(TCPS),and Static Var Compensator(SVC).SWEWOA expands Whale Optimization Algorithm(WOA)through the integration of sine and wormhole energy features thus improving exploration and exploitation capabilities for efficient convergence in complex non-linear OPF problems.A performance evaluation of SWEWOA takes place on the IEEE-30 bus test system through static and dynamic loading scenarios where it demonstrates better results than five contemporary algorithms:Adaptive Chaotic WOA(ACWOA),WOA,Chaotic WOA(CWOA),Sine Cosine Algorithm Differential Evolution(SCADE),and Hybrid Grey Wolf Optimization(HGWO).The research shows that SWEWOA delivers superior generation cost reduction than other algorithms by reaching a minimum of 0.9%better performance.SWEWOA demonstrates superior power loss performance by achieving(P_(loss,min))at the lowest level compared to all other tested algorithms which leads to better system energy efficiency.The dynamic loading performance of SWEWOA leads to a 4.38%reduction in gross costs which proves its capability to handle different operating conditions.The algorithm achieves top performance in Friedman Rank Test(FRT)assessments through multiple performance metrics which verifies its consistent reliability and strong stability during changing power demands.The repeated simulations show that SWEWOA generates mean costs(C_(gen,min))and mean power loss values(P_(loss,min))with small deviations which indicate its capability to maintain cost-effective solutions in each simulation run.SWEWOA demonstrates great potential as an advanced optimization solution for power system operations through the results presented in this study.展开更多
Hydraulic valve block is an important part of the hydraulic system.The traditional hydraulic valve block is made by turning and milling,drilling and boring,which leads to many right-angle bending and closed cavity str...Hydraulic valve block is an important part of the hydraulic system.The traditional hydraulic valve block is made by turning and milling,drilling and boring,which leads to many right-angle bending and closed cavity structure of process holes in its internal flow channel,seriously affecting the flow performance of oil.Based on the new design space provided by additive manufacturing technology,the internal hydraulic flow channel of valve block is optimized by using B-spline curve.Computational fluid dynamics analysis is carried out on the hydraulic flow channel to determine the optimal flow channel structure with the smallest pressure drop.The weight reduction of hydraulic valve block is carried out through topology optimization.According to the results of topology optimization,using the method of selective laser melting(SLM),the printing of the hydraulic valve block is completed.The optimized hydraulic channel reduces the pressure loss by 31.4%compared with the traditional hydraulic channel.Compared with the traditional valve block,the hydraulic valve block manufactured by SLM with topology optimization reduces the weight by 33.9%.Therefore,the proposed flow channel optimization and valve block lightweight method provide a new reference for the performance improvement of the internal flow channel of hydraulic valve block and the overall lightweight design of valve block.展开更多
Due to the increasing global demand for industrial gas, the development of large-scale cryogenic air separation systems has attracted considerable attention in recent years. Increasing the height of the adsorption bed...Due to the increasing global demand for industrial gas, the development of large-scale cryogenic air separation systems has attracted considerable attention in recent years. Increasing the height of the adsorption bed in a vertical radial flow adsorber used in cryogenic air separation systems may efficiently increase the treatment capacity of the air in the adsorber. However, uniformity of the flow distribution of the air inside the adsorber would be deteriorated using the height-increasing method. In order to reduce the non-uniformity of the flow distribution caused by the excessive height of adsorption bed in a vertical radial flow adsorber, a novel parallel connection method is proposed in the present work. The experimental apparatus is designed and constructed; the Computational Fluid Dynamics(CFD) technique is used to develop a CFD-based model, which is used to analyze the flow distribution, the static pressure drop and the radial velocity in the newly designed adsorber. In addition, the geometric parameters of annular flow channels and the adsorption bed thickness of the upper unit in the parallelconnected vertical radial flow adsorber are optimized, so that the upper and lower adsorption units could be penetrated by air simultaneously. Comparisons are made between the height-increasing method and the parallel connection method with the same adsorber height. It is shown that using the parallel connection method could reduce the difference between the maximum and minimum radial static pressure drop by 86.2% and improve the uniformity by 80% compared with those of using the height-increasing method. The optimal thickness ratio of the upper and lower adsorption units is obtained as 0.966, in which case the upper and lower adsorption units could be penetrated by air simultaneously, so that the adsorbents in adsorption space could be used more efficiently.展开更多
The hybrid flow shop scheduling problem with unrelated parallel machine is a typical NP-hard combinatorial optimization problem, and it exists widely in chemical, manufacturing and pharmaceutical industry. In this wor...The hybrid flow shop scheduling problem with unrelated parallel machine is a typical NP-hard combinatorial optimization problem, and it exists widely in chemical, manufacturing and pharmaceutical industry. In this work, a novel mathematic model for the hybrid flow shop scheduling problem with unrelated parallel machine(HFSPUPM) was proposed. Additionally, an effective hybrid estimation of distribution algorithm was proposed to solve the HFSPUPM, taking advantage of the features in the mathematic model. In the optimization algorithm, a new individual representation method was adopted. The(EDA) structure was used for global search while the teaching learning based optimization(TLBO) strategy was used for local search. Based on the structure of the HFSPUPM, this work presents a series of discrete operations. Simulation results show the effectiveness of the proposed hybrid algorithm compared with other algorithms.展开更多
The steady, laminar, incompressible and two dimensional micropolar flow between two porous disks was investigated using optimal homotopy asymptotic method(OHAM) and fourth order Runge–Kutta numerical method. Comparis...The steady, laminar, incompressible and two dimensional micropolar flow between two porous disks was investigated using optimal homotopy asymptotic method(OHAM) and fourth order Runge–Kutta numerical method. Comparison between OHAM and numerical method shows that OHAM is an exact and high efficient method for solving these kinds of problems. The results are presented to study the velocity and rotation profiles for different physical parameters such as Reynolds number, vortex viscosity parameter, spin gradient viscosity and microinertia density parameter. As an important outcome, the magnitude of the microrotation increases with an increase in the values of injection velocity while it decreases by increasing the values of suction velocity.展开更多
The effect of flow control devices(FCDs) on the uniformity of flow characteristics in a seven-strand symmetrical trapezoidal tundish was studied using both an experimental 1:2.5 hydraulic model and a numerical simu...The effect of flow control devices(FCDs) on the uniformity of flow characteristics in a seven-strand symmetrical trapezoidal tundish was studied using both an experimental 1:2.5 hydraulic model and a numerical simulation of a 1:1 geometric model.The variation coefficient(CV) was defined to evaluate the flow uniformity of the seven-strand tundish.An optimized FCD configuration was proposed on the basis of the evaluation of experimental results.It is concluded that a turbulence inhibitor(TI) and U-type dam are essential to improve the uniformity of fluid flow in the seven-strand tundish.In addition,the configuration of inclination T-type dams with a height of 200 mm between the second and third strands and with a height of 300 mm between the third and fourth strands can minimize the proportion of dead zone.After optimizing the configuration of FCDs,the variation coefficient reduces below 20%of the mean value,and the average proportion of dead zone is just 14.6%;in addition,the temperature fluctuation between the strands could be controlled within 0.6 K.In summary,the uniformity of flow and temperature in the seven-strand tundish is greatly improved.展开更多
The class of bi-directional optimal velocity models can describe the bi-directional looking effect that usually exists in the reality and is even enhanced with the development of the connected vehicle technologies. It...The class of bi-directional optimal velocity models can describe the bi-directional looking effect that usually exists in the reality and is even enhanced with the development of the connected vehicle technologies. Its combined string stability condition can be obtained through the method of the ring-road based string stability analysis. However, the partial string stability about traffic fluctuation propagated backward or forward was neglected, which will be analyzed in detail in this work by the method of transfer function and its H∞ norm from the viewpoint of control theory. Then, through comparing the conditions of combined and partial string stabilities, their relationships can make traffic flow be divided into three distinguishable regions, displaying various combined and partial string stability performance. Finally, the numerical experiments verify the theoretical results and find that the final displaying string stability or instability performance results from the accumulated and offset effects of traffic fluctuations propagated from different directions.展开更多
The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronizat...The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronization when the system is exposed to severe faults such as short circuits is referred to as the power system’s transient stability.As the power system’s safe and stable operation and mechanism of action become more complicated,higher demands for accurate and rapid power system transient stability analysis are made.Current methods for analyzing transient stability are less accurate because they do not account formisclassification of unstable samples.As a result,this paper proposes a novel approach for analyzing transient stability.The key concept is to use deep forest(DF)and a neighborhood rough reduction approach together.Using the neighborhood rough sets,the original feature space is obtained by creating many optimal feature subsets at various granularity levels.Then,by deploying the DF cascade structure,the mapping connection between the transient stability state and the features is reinforced.The weighted voting technique is used in the learning process to increase the classification accuracy of unstable samples.When contrasted to current methods,simulation results indicate that the proposed approach outperforms them.展开更多
In aero engine design, determining whether the preliminary design will have disruptive effects on the detailed design is the key to multidisciplinary design optimization in the preliminary design stage. In order to ad...In aero engine design, determining whether the preliminary design will have disruptive effects on the detailed design is the key to multidisciplinary design optimization in the preliminary design stage. In order to adapt to the non-orthogonal parameter value range caused by the selfconstrained parametric modeling method, a non-orthogonal space mapping method that maps the optimal Latin hypercube sampling points of the traditional orthogonal design space to the non-orthogonal design space is proposed. Based on the logical regression method in machine learning field, a kind of feasible domain boundary identification method is employed to identify whether the sample spatial response meets the relevant criteria. The method proposed in this paper is used to identify and analyze the key technologies of the high-pressure turbine mortise joint structure. It is found that the preliminary design of the aero engine may lead to the failure to obtain a mortise joint structure meeting the design requirements in the detailed design stage. The mortise joint structure needs to be pre-optimized in the preliminary design stage.展开更多
The reasonable determination of ecological flow is of great significance for the efforts to promote the transformation of water ecological environmental protection from pollution management to synergistic management o...The reasonable determination of ecological flow is of great significance for the efforts to promote the transformation of water ecological environmental protection from pollution management to synergistic management of water resources,water ecology and water environment,and to promote them in an integrated manner.This paper analyzed and calculated the ecological flow process of the Bangsha River diversion power station using the minimum ecological flow method,the annual spreading method,the improved annual spreading method,the NGPRP method,and the month-by-month frequency method,and evaluated the reasonableness of the process and results of the ecological flow calculations by using the fuzzy evaluation model established.The study showed that the minimum ecological flow rate determined by improving the coupling of the spreading method and the NGPRP method was the best,and the suitable ecological flow rate determined by the month-by-month frequency method was the best;the minimum ecological flow rate of the Bangsha River diversion power station was at 0.43-4.21 m 3/s,and the suitable ecological flow rate was at 0.56-4.94 m 3/s,and the trend of its change showed the trend of first increasing and then decreasing,and the trend of change from January to July showed the trend of first increasing and then decreasing.Its trend of change showed an increasing and then decreasing trend,from January to July showed a gradually increasing trend,from August to December showed a gradually decreasing trend.It aimed to provide a theoretical basis for the reasonable determination of the ecological flow of the river hydropower station.展开更多
文摘Ensuring the reliability of power systems in microgrids is critical,particularly under contingency conditions that can disrupt power flow and system stability.This study investigates the application of Security-Constrained Optimal Power Flow(SCOPF)using the Line Outage Distribution Factor(LODF)to enhance resilience in a renewable energy-integrated microgrid.The research examines a 30-bus system with 14 generators and an 8669 MW load demand,optimizing both single-objective and multi-objective scenarios.The single-objective opti-mization achieves a total generation cost of$47,738,while the multi-objective approach reduces costs to$47,614 and minimizes battery power output to 165.02 kW.Under contingency conditions,failures in transmission lines 1,22,and 35 lead to complete power loss in those lines,requiring a redistribution strategy.Implementing SCOPF mitigates these disruptions by adjusting power flows,ensuring no line exceeds its capacity.Specifically,in contingency 1,power in channel 4 is reduced from 59 to 32 kW,while overall load shedding is minimized to 0.278 MW.These results demonstrate the effectiveness of SCOPF in maintaining stability and reducing economic losses.Unlike prior studies,this work integrates LODF into SCOPF for large-scale microgrid applications,offering a computationally efficient contingency management framework that enhances grid resilience and supports renewable energy adoption.
文摘Due to the climate-dependent nature of renewable energy sources(RESs),solving the optimal power flow(OPF)problem in power systems that integrate RESs,such as photovoltaic(PV)units and wind turbines(WTs),remains a significant challenge.To address this problem,this study presents an effective framework that incorporates solar and wind power generation.To manage the nonconvex and nonlinear characteristics of the OPF problem,a modified physics-inspired algorithm termed the Enhanced Coulomb’s and Franklin’s laws Algorithm(ECFA),is deployed.In the proposed OPF model,the power generated from RESs is considered a dependent variable,while voltages at buses equipped with RESs serve as decision variables.Real-time data on solar irradiation and wind speed are used to model the power outputs of PV units and WTs,respectively.Although the Coulomb’s and Franklin’s law algorithm(CFA)offers some advantages,it underperforms on complex optimization tasks compared to SSA,BA,SCA,ABC,and CFA.The enhanced version of the CFA improves the search process across the feasible space by incorporating diverse interaction methods and enhancing exploitation capabilities.The performance of the proposed ECFA is assessed through comprehensive comparisons with state-of-the-art methods for solving the OPF problem.
基金Supported by the National Natural Science Foundation of China(21466026,61364009)NJZZ(14054)
文摘In order to increase the productivity of microreactors, the parallelization of the microreactors is required. The performances of flow distributors can affect the product yield and fault detection ability when blockage happens.In this research, an optimal design method to calculate the channel diameters and to determine the flow sensor location is derived based on mass balance and pressure balance models of split-and-recombine-type flow distributors(SRFDs). The model accuracy is verified by experiment data. The proposed method is applied to optimal design of SRFDs under constant flow rate operation conditions. The maximum angle difference between normal and blockage conditions at one sensor to those at the other sensors is set to be the objective function and the uniformity of flow distribution in microreactors under normal condition is also required. The diameters of each pipe in SRFDs are selected as the design variables. Simulated annealing algorithm is used to solve the optimization problem. The effectiveness of the optimal design results is demonstrated by fluid dynamics simulations. The results show that using the optimal channel diameters of SRFDs, the pressure drop in SRFD section is lower than that of the microreactor section. Meanwhile, in the case studies, only a few sensors that are located inside the SRFDs can easily detect the blockage abnormal condition in the parallelized microreactor system.
基金Projects(61105067,61174164)supported by the National Natural Science Foundation of China
文摘The artificial bee colony(ABC) algorithm is improved to construct a hybrid multi-objective ABC algorithm, called HMOABC, for resolving optimal power flow(OPF) problem by simultaneously optimizing three conflicting objectives of OPF, instead of transforming multi-objective functions into a single objective function. The main idea of HMOABC is to extend original ABC algorithm to multi-objective and cooperative mode by combining the Pareto dominance and divide-and-conquer approach. HMOABC is then used in the 30-bus IEEE test system for solving the OPF problem considering the cost, loss, and emission impacts. The simulation results show that the HMOABC is superior to other algorithms in terms of optimization accuracy and computation robustness.
文摘This paper proposes an efficient method for optimal power flow solution (OPF) using particle swarm optimization (PSO) technique. The objective of the proposed method is to find the steady state operation point in a power system which minimizes the fuel cost, while maintaining an acceptable system performance in terms of limits on generator power, line flow limits and voltage limits. In order to improvise the performance of the conventional PSO (cPSO), the fine tuning parameters- the inertia weight and acceleration coefficients are formulated in terms of global-local best values of the objective function. These global-local best inertia weight (GLBestlW) and global-local best acceleration coefficient (GLBestAC) are incorporated into PSO in order to compute the optimal power flow solution. The proposed method has been tested on the standard IEEE 30 bus test system to prove its efficacy. The results are compared with those obtained through cPSO. It is observed that the proposed algorithm is computationally faster, in terms of the number of load flows executed and provides better results than the conventional heuristic techniques.
基金National Natural Science Foundation of China(No.50595413)National Key Basic Research Program ("973" Program) (No.2004CB217904)
文摘The security constrained distributed optimal power flow (DOPF) of interconnected power systems is presented. The centralized OPF problem of the multi-area power systems is decomposed into independent DOPF subproblems, one for each area. The dynamic security region (DSR) to guarantee the transient stability constraints and static voltage stability region (SVSR) constraints, and line current limits are included as constraints. The solutions to the DOPF subproblems of the different areas are coordinated through a pricing mechanism until they converge to the centralized OPF solution. The nonlinear DOPF subproblem is solved by predictor-corrector interior point method (PClPM). The IEEE three-area RTS-96 system is worked out in order to demonstrate the effectiveness of the proposed method.
基金supported by the Deanship of Postgraduate Studies and Scientific Research at Majmaah University in Saudi Arabia under Project Number(ICR-2024-1002).
文摘In the contemporary era,the global expansion of electrical grids is propelled by various renewable energy sources(RESs).Efficient integration of stochastic RESs and optimal power flow(OPF)management are critical for network optimization.This study introduces an innovative solution,the Gaussian Bare-Bones Levy Cheetah Optimizer(GBBLCO),addressing OPF challenges in power generation systems with stochastic RESs.The primary objective is to minimize the total operating costs of RESs,considering four functions:overall operating costs,voltage deviation management,emissions reduction,voltage stability index(VSI)and power loss mitigation.Additionally,a carbon tax is included in the objective function to reduce carbon emissions.Thorough scrutiny,using modified IEEE 30-bus and IEEE 118-bus systems,validates GBBLCO’s superior performance in achieving optimal solutions.Simulation results demonstrate GBBLCO’s efficacy in six optimization scenarios:total cost with valve point effects,total cost with emission and carbon tax,total cost with prohibited operating zones,active power loss optimization,voltage deviation optimization and enhancing voltage stability index(VSI).GBBLCO outperforms conventional techniques in each scenario,showcasing rapid convergence and superior solution quality.Notably,GBBLCO navigates complexities introduced by valve point effects,adapts to environmental constraints,optimizes costs while considering prohibited operating zones,minimizes active power losses,and optimizes voltage deviation by enhancing the voltage stability index(VSI)effectively.This research significantly contributes to advancing OPF,emphasizing GBBLCO’s improved global search capabilities and ability to address challenges related to local minima.GBBLCO emerges as a versatile and robust optimization tool for diverse challenges in power systems,offering a promising solution for the evolving needs of renewable energy-integrated power grids.
文摘This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or absorbed using the available capacity and the adjustable power factor of the inverter. The reduction of unbalance voltage and losses in the distribution systems is obtained by actions of reactive power control of the inverter. The TOPF is formulated by current balance equations and the PV systems are modeled via an equivalent circuit. The primal-dual interior point method is used to obtain the optimal operating points for the systems for different scenarios of solar irradiance and temperature, thus providing a detailed view of the impact of photovoltaic distributed generation.
文摘This paper addresses the problem of reducing CO<sub>2</sub> emissions by applying convex optimal power flow model to the combined economic and emission dispatch problem. The large amount of CO<sub>2</sub> emissions in the power industry is a major source of global warming effect. An efficient and economic approach to reduce CO<sub>2</sub> emissions is to formulate the emission reduction problem as emission dispatch problem and combined with power system economic dispatch (ED). Because the traditional optimal power flow (OPF) model used by the economic dispatch is nonlinear and nonconvex, current nonlinear solvers are not able to find the global optimal solutions. In this paper, we use the convex optimal power flow model to formulate the combined economic and emission dispatch problem. The advantage of using convex power flow model is that global optimal solutions can be obtained by using mature industrial strength nonlinear solvers such as MOSEK. Numerical results of various IEEE power network test cases confirm the feasibility and advantage of convex combined economic and emission dispatch (CCEED).
文摘Firefly algorithm is the new intelligent algorithm used for all complex engineering optimization problems. Power system has many complex optimization problems one of which is the optimal power flow (OPF). Basically, it is minimizing optimization problem and subjected to many complex objective functions and constraints. Hence, firefly algorithm is used to solve OPF in this paper. The aim of the firefly is to optimize the control variables, namely generated real power, voltage magnitude and tap setting of transformers. Flexible AC Transmission system (FACTS) devices may used in the power system to improve the quality of the power supply and to reduce the cost of the generation. FACTS devices are classified into series, shunt, shunt-series and series-series connected devices. Unified power flow controller (UPFC) is shunt-series type device that posses all capabilities to control real, reactive powers, voltage and reactance of the connected line in the power system. Hence, UPFC is included in the considered IEEE 30 bus for the OPF solution.
文摘The Sine and Wormhole Energy Whale Optimization Algorithm(SWEWOA)represents an advanced solution method for resolving Optimal Power Flow(OPF)problems in power systems equipped with Flexible AC Transmission System(FACTS)devices which include Thyristor-Controlled Series Compensator(TCSC),Thyristor-Controlled Phase Shifter(TCPS),and Static Var Compensator(SVC).SWEWOA expands Whale Optimization Algorithm(WOA)through the integration of sine and wormhole energy features thus improving exploration and exploitation capabilities for efficient convergence in complex non-linear OPF problems.A performance evaluation of SWEWOA takes place on the IEEE-30 bus test system through static and dynamic loading scenarios where it demonstrates better results than five contemporary algorithms:Adaptive Chaotic WOA(ACWOA),WOA,Chaotic WOA(CWOA),Sine Cosine Algorithm Differential Evolution(SCADE),and Hybrid Grey Wolf Optimization(HGWO).The research shows that SWEWOA delivers superior generation cost reduction than other algorithms by reaching a minimum of 0.9%better performance.SWEWOA demonstrates superior power loss performance by achieving(P_(loss,min))at the lowest level compared to all other tested algorithms which leads to better system energy efficiency.The dynamic loading performance of SWEWOA leads to a 4.38%reduction in gross costs which proves its capability to handle different operating conditions.The algorithm achieves top performance in Friedman Rank Test(FRT)assessments through multiple performance metrics which verifies its consistent reliability and strong stability during changing power demands.The repeated simulations show that SWEWOA generates mean costs(C_(gen,min))and mean power loss values(P_(loss,min))with small deviations which indicate its capability to maintain cost-effective solutions in each simulation run.SWEWOA demonstrates great potential as an advanced optimization solution for power system operations through the results presented in this study.
基金supported by the National Natural Science Foundation of China(No.51775273)the Jiangsu Province Science and Technology Support Plan Project(No.BE2018010-2)+2 种基金the National Defence Basic Scientific Research Program of China(No.JCKY2018605C010)the Frontiers of Science and Technology Program of China (No.1816312ZT00406301)the Aeronautical Science Foundation of China(No.2020Z049052002)
文摘Hydraulic valve block is an important part of the hydraulic system.The traditional hydraulic valve block is made by turning and milling,drilling and boring,which leads to many right-angle bending and closed cavity structure of process holes in its internal flow channel,seriously affecting the flow performance of oil.Based on the new design space provided by additive manufacturing technology,the internal hydraulic flow channel of valve block is optimized by using B-spline curve.Computational fluid dynamics analysis is carried out on the hydraulic flow channel to determine the optimal flow channel structure with the smallest pressure drop.The weight reduction of hydraulic valve block is carried out through topology optimization.According to the results of topology optimization,using the method of selective laser melting(SLM),the printing of the hydraulic valve block is completed.The optimized hydraulic channel reduces the pressure loss by 31.4%compared with the traditional hydraulic channel.Compared with the traditional valve block,the hydraulic valve block manufactured by SLM with topology optimization reduces the weight by 33.9%.Therefore,the proposed flow channel optimization and valve block lightweight method provide a new reference for the performance improvement of the internal flow channel of hydraulic valve block and the overall lightweight design of valve block.
基金Supported by the National Key R&D Program of China(2017YFB0603702)the Natural Science Foundation of Zhejiang Province(Y15E060014)+1 种基金the National Natural Science Foundation of China(51636007)Shanghai Young Teachers Development Program(10-16-301-801)
文摘Due to the increasing global demand for industrial gas, the development of large-scale cryogenic air separation systems has attracted considerable attention in recent years. Increasing the height of the adsorption bed in a vertical radial flow adsorber used in cryogenic air separation systems may efficiently increase the treatment capacity of the air in the adsorber. However, uniformity of the flow distribution of the air inside the adsorber would be deteriorated using the height-increasing method. In order to reduce the non-uniformity of the flow distribution caused by the excessive height of adsorption bed in a vertical radial flow adsorber, a novel parallel connection method is proposed in the present work. The experimental apparatus is designed and constructed; the Computational Fluid Dynamics(CFD) technique is used to develop a CFD-based model, which is used to analyze the flow distribution, the static pressure drop and the radial velocity in the newly designed adsorber. In addition, the geometric parameters of annular flow channels and the adsorption bed thickness of the upper unit in the parallelconnected vertical radial flow adsorber are optimized, so that the upper and lower adsorption units could be penetrated by air simultaneously. Comparisons are made between the height-increasing method and the parallel connection method with the same adsorber height. It is shown that using the parallel connection method could reduce the difference between the maximum and minimum radial static pressure drop by 86.2% and improve the uniformity by 80% compared with those of using the height-increasing method. The optimal thickness ratio of the upper and lower adsorption units is obtained as 0.966, in which case the upper and lower adsorption units could be penetrated by air simultaneously, so that the adsorbents in adsorption space could be used more efficiently.
基金Projects(61573144,61773165,61673175,61174040)supported by the National Natural Science Foundation of ChinaProject(222201717006)supported by the Fundamental Research Funds for the Central Universities,China
文摘The hybrid flow shop scheduling problem with unrelated parallel machine is a typical NP-hard combinatorial optimization problem, and it exists widely in chemical, manufacturing and pharmaceutical industry. In this work, a novel mathematic model for the hybrid flow shop scheduling problem with unrelated parallel machine(HFSPUPM) was proposed. Additionally, an effective hybrid estimation of distribution algorithm was proposed to solve the HFSPUPM, taking advantage of the features in the mathematic model. In the optimization algorithm, a new individual representation method was adopted. The(EDA) structure was used for global search while the teaching learning based optimization(TLBO) strategy was used for local search. Based on the structure of the HFSPUPM, this work presents a series of discrete operations. Simulation results show the effectiveness of the proposed hybrid algorithm compared with other algorithms.
文摘The steady, laminar, incompressible and two dimensional micropolar flow between two porous disks was investigated using optimal homotopy asymptotic method(OHAM) and fourth order Runge–Kutta numerical method. Comparison between OHAM and numerical method shows that OHAM is an exact and high efficient method for solving these kinds of problems. The results are presented to study the velocity and rotation profiles for different physical parameters such as Reynolds number, vortex viscosity parameter, spin gradient viscosity and microinertia density parameter. As an important outcome, the magnitude of the microrotation increases with an increase in the values of injection velocity while it decreases by increasing the values of suction velocity.
基金supported by the National Natural Science Foundation of China (No.51404018)the Fundamental Research Funds for the Central Universities of China (No.FRF-TP-15-008A3)
文摘The effect of flow control devices(FCDs) on the uniformity of flow characteristics in a seven-strand symmetrical trapezoidal tundish was studied using both an experimental 1:2.5 hydraulic model and a numerical simulation of a 1:1 geometric model.The variation coefficient(CV) was defined to evaluate the flow uniformity of the seven-strand tundish.An optimized FCD configuration was proposed on the basis of the evaluation of experimental results.It is concluded that a turbulence inhibitor(TI) and U-type dam are essential to improve the uniformity of fluid flow in the seven-strand tundish.In addition,the configuration of inclination T-type dams with a height of 200 mm between the second and third strands and with a height of 300 mm between the third and fourth strands can minimize the proportion of dead zone.After optimizing the configuration of FCDs,the variation coefficient reduces below 20%of the mean value,and the average proportion of dead zone is just 14.6%;in addition,the temperature fluctuation between the strands could be controlled within 0.6 K.In summary,the uniformity of flow and temperature in the seven-strand tundish is greatly improved.
基金Projects(51108465,71371192)supported by the National Natural Science Foundation of ChinaProject(2014M552165)supported by China Postdoctoral Science FoundationProject(20113187851460)supported by Technology Project of the Ministry of Transport of China
文摘The class of bi-directional optimal velocity models can describe the bi-directional looking effect that usually exists in the reality and is even enhanced with the development of the connected vehicle technologies. Its combined string stability condition can be obtained through the method of the ring-road based string stability analysis. However, the partial string stability about traffic fluctuation propagated backward or forward was neglected, which will be analyzed in detail in this work by the method of transfer function and its H∞ norm from the viewpoint of control theory. Then, through comparing the conditions of combined and partial string stabilities, their relationships can make traffic flow be divided into three distinguishable regions, displaying various combined and partial string stability performance. Finally, the numerical experiments verify the theoretical results and find that the final displaying string stability or instability performance results from the accumulated and offset effects of traffic fluctuations propagated from different directions.
基金The authors extend their appreciation to the Deanship of Scientific Research at Jouf University for funding this work through research Grant No.(DSR-2021-02-0113).
文摘The effect of energy on the natural environment has become increasingly severe as human consumption of fossil energy has increased.The capacity of the synchronous generators to keep working without losing synchronization when the system is exposed to severe faults such as short circuits is referred to as the power system’s transient stability.As the power system’s safe and stable operation and mechanism of action become more complicated,higher demands for accurate and rapid power system transient stability analysis are made.Current methods for analyzing transient stability are less accurate because they do not account formisclassification of unstable samples.As a result,this paper proposes a novel approach for analyzing transient stability.The key concept is to use deep forest(DF)and a neighborhood rough reduction approach together.Using the neighborhood rough sets,the original feature space is obtained by creating many optimal feature subsets at various granularity levels.Then,by deploying the DF cascade structure,the mapping connection between the transient stability state and the features is reinforced.The weighted voting technique is used in the learning process to increase the classification accuracy of unstable samples.When contrasted to current methods,simulation results indicate that the proposed approach outperforms them.
文摘In aero engine design, determining whether the preliminary design will have disruptive effects on the detailed design is the key to multidisciplinary design optimization in the preliminary design stage. In order to adapt to the non-orthogonal parameter value range caused by the selfconstrained parametric modeling method, a non-orthogonal space mapping method that maps the optimal Latin hypercube sampling points of the traditional orthogonal design space to the non-orthogonal design space is proposed. Based on the logical regression method in machine learning field, a kind of feasible domain boundary identification method is employed to identify whether the sample spatial response meets the relevant criteria. The method proposed in this paper is used to identify and analyze the key technologies of the high-pressure turbine mortise joint structure. It is found that the preliminary design of the aero engine may lead to the failure to obtain a mortise joint structure meeting the design requirements in the detailed design stage. The mortise joint structure needs to be pre-optimized in the preliminary design stage.
文摘The reasonable determination of ecological flow is of great significance for the efforts to promote the transformation of water ecological environmental protection from pollution management to synergistic management of water resources,water ecology and water environment,and to promote them in an integrated manner.This paper analyzed and calculated the ecological flow process of the Bangsha River diversion power station using the minimum ecological flow method,the annual spreading method,the improved annual spreading method,the NGPRP method,and the month-by-month frequency method,and evaluated the reasonableness of the process and results of the ecological flow calculations by using the fuzzy evaluation model established.The study showed that the minimum ecological flow rate determined by improving the coupling of the spreading method and the NGPRP method was the best,and the suitable ecological flow rate determined by the month-by-month frequency method was the best;the minimum ecological flow rate of the Bangsha River diversion power station was at 0.43-4.21 m 3/s,and the suitable ecological flow rate was at 0.56-4.94 m 3/s,and the trend of its change showed the trend of first increasing and then decreasing,and the trend of change from January to July showed the trend of first increasing and then decreasing.Its trend of change showed an increasing and then decreasing trend,from January to July showed a gradually increasing trend,from August to December showed a gradually decreasing trend.It aimed to provide a theoretical basis for the reasonable determination of the ecological flow of the river hydropower station.