AIM:To investigate the impact of preoperative anterior corneal topographic parameters on the morphology of the postoperative effective optical zone(EOZ)in patients undergoing keratorefractive lenticule extraction(KLEx...AIM:To investigate the impact of preoperative anterior corneal topographic parameters on the morphology of the postoperative effective optical zone(EOZ)in patients undergoing keratorefractive lenticule extraction(KLEx)and wavefront-guided LASIK(WG-LASIK).METHODS:This retrospective study included 310 eyes from patients who underwent either KLEx(via small incision lenticule extraction,171 eyes)or WG-LASIK(139 eyes).Patients were stratified into subgroups based on the median values of spherical equivalent(SE)and anterior corneal topographic parameters.Postoperative EOZ parameters were measured 1mo after surgery and compared across subgroups.Correlation analysis and multivariable linear regression analysis were performed to explore the associations between preoperative anterior corneal topographic parameters and EOZ parameters.RESULTS:A total of 310 eyes were included(KLEx:171 eyes from 88 patients;WG-LASIK:139 eyes from 82 patients).The mean age was 30.65±5.67y in the KLEx cohort and 29.06±5.94y in the WG-LASIK cohort.In the KLEx cohort,SE,preoperative mean keratometry(Km),steep keratometry(K2),and anterior corneal astigmatism(K2-K1)were positively correlated with the postoperative optical zone reduction ratio(RR=EOZ/planned optical zone×100%;all P<0.01).Multivariable regression identified SE[β=0.027,95%confidence interval(CI):0.022-0.032,P<0.001],Km(β=0.009,95%CI:0.002-0.016,P=0.014),and anterior corneal astigmatism(β=0.031,95%CI:0.013-0.049,P<0.001)as significant predictors of RR(R²=0.456,P<0.001).In the WG-LASIK cohort,SE was positively correlated with RR(P<0.01);K2 and anterior corneal astigmatism were positively correlated with both RR(P<0.05)and EOZ eccentricity(P<0.01).Multivariable regression showed SE(β=0.015,95%CI:0.007-0.023,P<0.001)and anterior corneal astigmatism(β=0.029,95%CI:0.012-0.047,P=0.001)were significant predictors of RR(R²=0.121,P<0.001).CONCLUSION:Preoperative anterior corneal topographic parameters,particularly anterior corneal astigmatism,significantly affect postoperative EOZ morphology in both KLEx and WG-LASIK.Additionally,Km is a predictor of EOZ reduction specifically in KLEx.展开更多
AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential as...AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential associated factors for FOZ.METHODS:A total of 133 patients who received corneal refractive surgery in our hospital between November 2018 and July 2021 were retrospectively enrolled.There were 63 patients(123 eyes)in SMILE group and 70patients(139 eyes)in FS-LASIK group.The size of FOZ was measured using Pentacam 3-dementional anterior segment analyzer before and 3mo after surgery,so as to analyze postoperative achieved functional optical zone(AFOZ)and its contributing parameters.RESULTS:When planned functional optical zone(PFOZ)was 6.5 mm for both groups,AFOZ was 1.45±0.27 and 1.67±0.25 mm smaller than preoperative FOZ in SMILE group and FS-LASIK group 3mo after surgery.AFOZ in SMILE group was significantly larger than that in FS-LASIK group(P<0.001).Variation of FOZ was negatively correlated with preoperative spherical equivalent(SE)and positively correlated with variation of mean keratometry value(△Km),variation of spherical aberration(△SA),and variation of Q-value(△Q,all P<0.001)in both groups.Multiple variable linear regression equations were△FOZ=1.354-0.1×pre-SE+0.336×△Q+1.462×△SA in SMILE group and△FOZ=1.512+0.137×△Q+0.468×△SA in FS-LASIK group.CONCLUSION:AFOZ is significantly smaller than preoperative FOZ in both SMILE and FS-LASIK groups.With the same PFOZ,larger AFOZ is achieved in SMILE group than in FS-LASIK group.展开更多
Background:In this retrospective randomized case series,we compared bilateral symmetry between OD and OS eyes,intercorneal differences and Functional Optical Zone(FOZ)of the corneal aberrations.Methods:Sixty-seven nor...Background:In this retrospective randomized case series,we compared bilateral symmetry between OD and OS eyes,intercorneal differences and Functional Optical Zone(FOZ)of the corneal aberrations.Methods:Sixty-seven normal subjects(with no ocular pathology)who never had any ocular surgery were bilaterally evaluated at Augenzentrum Recklinghausen(Germany).In all cases,standard examinations and corneal wavefront topography(OPTIKON Scout)were performed.The OD/OS bilateral symmetry was evaluated for corneal wavefront aberrations,and FOZ-values were evaluated from the Root-Mean-Square(RMS)of High-Order Wavefront-Aberration(HOWAb).Moreover,correlations of FOZ,spherical equivalent(SE),astigmatism power,and cardinal and oblique astigmatism for binocular vs.monocular,and binocular vs.intercorneal differences were analyzed.Results:Mean FOZ was 6.56±1.13 mm monocularly,6.97±1.34 mm binocularly,and 7.64±1.30 mm intercorneal difference,with all strongly positively correlated,showing that the diameter of glare-free vision is larger in binocular than monocular conditions.Mean SE was 0.78±1.30 D,and the mean astigmatism power(magnitude)was 0.46±0.52 D binocularly.The corresponding monocular values for these metrics were 0.78±1.30 D and 0.53±0.53 D respectively.SE,astigmatism magnitude,cardinal astigmatism component,and FOZ showed a strong correlation and even symmetry;and oblique astigmatism component showed odd symmetry indicating Enantiomorphism between the left and right eye.Conclusions:These results confirm OD-vs.-OS bilateral symmetry(which influences binocular summation)of HOWAb,FOZ,defocus,astigmatism power,and cardinal and oblique astigmatism.Binocular Functional Optical Zone calculated from corneal wavefront aberrations can be used to optimize refractive surgery design.展开更多
AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in ...AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in children.METHODS:This randomized clinical study was performed between Dec.2020 and Dec.2021.Participants were randomly assigned to three groups wearing ortho-k:5 mm BOZD(5-MM group),5.5 mm BOZD(5.5-MM group),and 6 mm BOZD(6-MM group).The 1-year data were recorded,including axial length,relative peripheral refraction(RPR,measured by multispectral refractive topography,MRT),and visual quality.The contrast sensitivity(CS)was evaluated by CSV-1000 instrument with spatial frequencies of 3,6,12,and 18 cycles/degree(c/d);the corneal higher-order aberrations(HOAs)were measured by iTrace aberration analyzer.The one-way ANOVA was performed to assess the differences between the three groups.The correlation between the change in AL and RPR was calculated by Pearson’s correlation coefficient.RESULTS:The 1-year results of 20,21,and 21 subjects in the 5-MM,5.5-MM,and 6-MM groups,respectively,were presented.There were no statistical differences in baseline age,sex,or ocular parameters between the three groups(all P>0.05).At the 1-year visit,the 5-MM group had lower axial elongation than the 6-MM group(0.07±0.09 vs 0.18±0.11 mm,P=0.001).The 5-MM group had more myopic total RPR(TRPR,P=0.014),with RPR in the 15°–30°(RPR 15–30,P=0.015),30°–45°(RPR 30–45,P=0.011),temporal(RPR-T,P=0.008),and nasal area(RPR-N,P<0.001)than the 6-MM group.RPR 15–30 in the 5.5-MM group was more myopic than that in the 6-MM group(P=0.002),and RPR-N in the 5-MM group was more myopic than that in the 5.5-MM group(P<0.001).There were positive correlations between the axial elongation and the change in TRPR(r=0.756,P<0.001),RPR 15–30(r=0.364,P=0.004),RPR 30–45(r=0.306,P=0.016),and RPR-N(r=0.253,P=0.047).The CS decreased at 3 c/d(P<0.001),and the corneal HOAs increased in the 5-MM group(P=0.030).CONCLUSION:Ortho-k with 5 mm BOZD can control myopia progression more effectively.The mechanism may be associated with greater myopic shifts in RPR.展开更多
Light manipulation and control are essential in various contemporary technologies,and as these technologies evolve,the demand for miniaturized optical components increases.Planar-lens technologies,such as metasurfaces...Light manipulation and control are essential in various contemporary technologies,and as these technologies evolve,the demand for miniaturized optical components increases.Planar-lens technologies,such as metasurfaces and difractive optical elements,have gained attention in recent years for their potential to dramatically reduce the thickness of traditional refractive optical systems.However,their fabrication,particularly for visible wavelengths,involves complex and costly processes,such as high-resolution lithography and dry-etching,which has limited their availability.In this study,we present a simplifed method forfabricating visible Fresnel zone plate(FZP)planar lenses,a type of diffractive optical element,using an i-line stepper and a special photoresist(color resist)that only necessitates coating,exposure,and development,eliminating the need for etching or other post-processing steps.We fabricated visible FZp lens patterns using conventional photolithography equipment on 8-inch silica glass wafers,and demonstrated focusing of 550 nm light to a diameter of 1.1μm with a focusing efficiency of 7.2%.Numerical simulations showed excellent agreement with experimental results,confirming the high precision and designability of our method.Our lenses were also able to image objects with features down to 1.1μm,showcasing their potential for practical applications in imaging.Our method is a cost-effective,simple,and scalable solution for mass production of planar lenses and other optical components operating in the visible region.It enables the development of advanced,miniaturized optical systems to meet modern technology demand,making it a valuable contribution to optical component manufacturing.展开更多
The development of blue semiconductor light-emitting diodes(LEDs)has produced potential applications for Prdoped materials that can absorb blue light,especially crystals,and we now report structure and optical propert...The development of blue semiconductor light-emitting diodes(LEDs)has produced potential applications for Prdoped materials that can absorb blue light,especially crystals,and we now report structure and optical properties for high-quality Pr-doped single crystals of yttria-stabilized zirconia(YSZ)grown by the optical floating zone(FZ)method.X-ray diffraction(XRD)and Raman spectroscopy showed that all of the single crystal samples were in the cubic phase,whereas the corresponding ceramic samples contained a mixture of monoclinic and cubic phases.X-ray photoelectron spectroscopy(XPS)and electron paramagnetic resonance(EPR)spectroscopy showed that Pr was present as the Pr^(3+)ion in ceramic rods and single crystals after heating to high temperatures.The absorption and photoluminescence excitation(PLE)spectra of the Pr-doped YSZ crystals measured at room temperature showed strong absorption of blue light,while their photoluminescence(PL)spectra showed five emission peaks at 565 nm,588 nm,614 nm,638 nm,and 716 nm under450 nm excitation.The optimum luminescence properties were obtained with the crystal prepared using 0.15 mol%Pr_(6)O_(11),and those with higher concentrations showed evidence of quenching of the luminescence properties.In addition,the color purity of Pr-doped YSZ single crystal reached 98.9%in the orange–red region.展开更多
Columbite Zn0.8Co0.2Nb2O6 crystals were grown by optical floating zone methods. The x-ray diffraction(XRD) was used to check the structure information of the grown Zn0.8Co0.2Nb2O6 crystal. The room temperature and tem...Columbite Zn0.8Co0.2Nb2O6 crystals were grown by optical floating zone methods. The x-ray diffraction(XRD) was used to check the structure information of the grown Zn0.8Co0.2Nb2O6 crystal. The room temperature and temperature-dependent Raman spectra were tested to investigate the optical phonon behaviors of columbite Zn0.8Co0.2Nb2O6, which exhibited a temperature stable property. The magnetics properties of Zn0.8Co0.2Nb2O6, measured by a physical property measurement system(PPMS), were also presented in this work.展开更多
Background To investigate the control effect on the axial length elongation using corneal refractive therapy(CRT)with different optical zone diameters(BOZDs).We also sought to compare the difference in higher-order ab...Background To investigate the control effect on the axial length elongation using corneal refractive therapy(CRT)with different optical zone diameters(BOZDs).We also sought to compare the difference in higher-order aberrations(HOAs),treatment zone(TZ)size and Zernike defocus coefficient with different BOZDs and seek the optimal parameter for predicting axial elongation.Methods This prospective cohort study included 7-to 14-year-olds fitted with orthokeratology(ortho-K)lenses of 5-mm(5-mm group)or 6-mm BOZD(6-mm group).Axial length(AL),corneal topography,HOAs and Zernike defocus coefficient were obtained at baseline,and 1,3,6,9 and 12 months follow-up visits.Multivariate regression analyses were used to explore the association between AL change and ocular biometric parameters.Receiver operating characteristic(ROC)curve analysis was used to determine the best diagnostic value for AL change in ocular biometric parameters.Results In total,301 participants completed the one-year follow-up.The mean AL change in the 5-mm group(0.13±0.18 mm)was less than that in the 6-mm group(0.27±0.15 mm)at the 12 months visit.The TZ size and decentration were smaller,while the Zernike defocus coefficient and HOAs were higher in the 5-mm group(all P<0.05).Older age and smaller TZ size were protective factors against AL elongation in multiple regression.In predicting AL elongation,TZ diameter yielded an area under the ROC curve of 0.684 with a cut-off value of 3.82 mm.Conclusion The 5-mm group showed 0.14 mm(51.8%)less axial elongation than the 6-mm group.The 5-mm BOZD produced a smaller TZ size,higher Zernike defocus coefficient and higher HOA after reshaping of the cornea.TZ size was the best predictor of AL elongation.TZ diameter less than 3.82 mm may lead to AL elongation less than 0.2 mm in one year.展开更多
A series of high quality Dy_(2)O_(3) and Tm_(2)O_(3)co-doped yttria stabilized zirconia(YSZ) single crystals was synthesized.These crystals have a single cubic structure,and exhibit the characteristic of Dy^(3+)(blue ...A series of high quality Dy_(2)O_(3) and Tm_(2)O_(3)co-doped yttria stabilized zirconia(YSZ) single crystals was synthesized.These crystals have a single cubic structure,and exhibit the characteristic of Dy^(3+)(blue and yellow emissions) and Tm^(3+)(blue emission) under excitation with NUV light.Impo rtantly,the hue can be varied between blue and white by modifying the Tm^(3+)/Dy^(3+)ratio.The photoluminescence and decay curves are consistent with the existence of resonance-type energy transfer from Tm^(3+)to Dy^(3+)ions via an electric multipole interaction mechanism.Maximum luminescence intensity is observed in YSZ doped with 0.50 mol% Tm_(2)O_(3) and 0.75 mol% Dy_(2)O_(3),and this sample has CIE coordinates(x = 0.33,y = 0.33) in accordance with those for white chromaticity.Thus,the outstanding luminescence properties of these single crystals suggest potential applications in white light emission devices.展开更多
文摘AIM:To investigate the impact of preoperative anterior corneal topographic parameters on the morphology of the postoperative effective optical zone(EOZ)in patients undergoing keratorefractive lenticule extraction(KLEx)and wavefront-guided LASIK(WG-LASIK).METHODS:This retrospective study included 310 eyes from patients who underwent either KLEx(via small incision lenticule extraction,171 eyes)or WG-LASIK(139 eyes).Patients were stratified into subgroups based on the median values of spherical equivalent(SE)and anterior corneal topographic parameters.Postoperative EOZ parameters were measured 1mo after surgery and compared across subgroups.Correlation analysis and multivariable linear regression analysis were performed to explore the associations between preoperative anterior corneal topographic parameters and EOZ parameters.RESULTS:A total of 310 eyes were included(KLEx:171 eyes from 88 patients;WG-LASIK:139 eyes from 82 patients).The mean age was 30.65±5.67y in the KLEx cohort and 29.06±5.94y in the WG-LASIK cohort.In the KLEx cohort,SE,preoperative mean keratometry(Km),steep keratometry(K2),and anterior corneal astigmatism(K2-K1)were positively correlated with the postoperative optical zone reduction ratio(RR=EOZ/planned optical zone×100%;all P<0.01).Multivariable regression identified SE[β=0.027,95%confidence interval(CI):0.022-0.032,P<0.001],Km(β=0.009,95%CI:0.002-0.016,P=0.014),and anterior corneal astigmatism(β=0.031,95%CI:0.013-0.049,P<0.001)as significant predictors of RR(R²=0.456,P<0.001).In the WG-LASIK cohort,SE was positively correlated with RR(P<0.01);K2 and anterior corneal astigmatism were positively correlated with both RR(P<0.05)and EOZ eccentricity(P<0.01).Multivariable regression showed SE(β=0.015,95%CI:0.007-0.023,P<0.001)and anterior corneal astigmatism(β=0.029,95%CI:0.012-0.047,P=0.001)were significant predictors of RR(R²=0.121,P<0.001).CONCLUSION:Preoperative anterior corneal topographic parameters,particularly anterior corneal astigmatism,significantly affect postoperative EOZ morphology in both KLEx and WG-LASIK.Additionally,Km is a predictor of EOZ reduction specifically in KLEx.
基金Supported by Scientific and Technological Innovation Programs of Higher Education Institutions in Shanxi(No.2022L201)。
文摘AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential associated factors for FOZ.METHODS:A total of 133 patients who received corneal refractive surgery in our hospital between November 2018 and July 2021 were retrospectively enrolled.There were 63 patients(123 eyes)in SMILE group and 70patients(139 eyes)in FS-LASIK group.The size of FOZ was measured using Pentacam 3-dementional anterior segment analyzer before and 3mo after surgery,so as to analyze postoperative achieved functional optical zone(AFOZ)and its contributing parameters.RESULTS:When planned functional optical zone(PFOZ)was 6.5 mm for both groups,AFOZ was 1.45±0.27 and 1.67±0.25 mm smaller than preoperative FOZ in SMILE group and FS-LASIK group 3mo after surgery.AFOZ in SMILE group was significantly larger than that in FS-LASIK group(P<0.001).Variation of FOZ was negatively correlated with preoperative spherical equivalent(SE)and positively correlated with variation of mean keratometry value(△Km),variation of spherical aberration(△SA),and variation of Q-value(△Q,all P<0.001)in both groups.Multiple variable linear regression equations were△FOZ=1.354-0.1×pre-SE+0.336×△Q+1.462×△SA in SMILE group and△FOZ=1.512+0.137×△Q+0.468×△SA in FS-LASIK group.CONCLUSION:AFOZ is significantly smaller than preoperative FOZ in both SMILE and FS-LASIK groups.With the same PFOZ,larger AFOZ is achieved in SMILE group than in FS-LASIK group.
文摘Background:In this retrospective randomized case series,we compared bilateral symmetry between OD and OS eyes,intercorneal differences and Functional Optical Zone(FOZ)of the corneal aberrations.Methods:Sixty-seven normal subjects(with no ocular pathology)who never had any ocular surgery were bilaterally evaluated at Augenzentrum Recklinghausen(Germany).In all cases,standard examinations and corneal wavefront topography(OPTIKON Scout)were performed.The OD/OS bilateral symmetry was evaluated for corneal wavefront aberrations,and FOZ-values were evaluated from the Root-Mean-Square(RMS)of High-Order Wavefront-Aberration(HOWAb).Moreover,correlations of FOZ,spherical equivalent(SE),astigmatism power,and cardinal and oblique astigmatism for binocular vs.monocular,and binocular vs.intercorneal differences were analyzed.Results:Mean FOZ was 6.56±1.13 mm monocularly,6.97±1.34 mm binocularly,and 7.64±1.30 mm intercorneal difference,with all strongly positively correlated,showing that the diameter of glare-free vision is larger in binocular than monocular conditions.Mean SE was 0.78±1.30 D,and the mean astigmatism power(magnitude)was 0.46±0.52 D binocularly.The corresponding monocular values for these metrics were 0.78±1.30 D and 0.53±0.53 D respectively.SE,astigmatism magnitude,cardinal astigmatism component,and FOZ showed a strong correlation and even symmetry;and oblique astigmatism component showed odd symmetry indicating Enantiomorphism between the left and right eye.Conclusions:These results confirm OD-vs.-OS bilateral symmetry(which influences binocular summation)of HOWAb,FOZ,defocus,astigmatism power,and cardinal and oblique astigmatism.Binocular Functional Optical Zone calculated from corneal wavefront aberrations can be used to optimize refractive surgery design.
基金Supported by Education Department Foundation of Sichuan Province(No.15ZA0262).
文摘AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in children.METHODS:This randomized clinical study was performed between Dec.2020 and Dec.2021.Participants were randomly assigned to three groups wearing ortho-k:5 mm BOZD(5-MM group),5.5 mm BOZD(5.5-MM group),and 6 mm BOZD(6-MM group).The 1-year data were recorded,including axial length,relative peripheral refraction(RPR,measured by multispectral refractive topography,MRT),and visual quality.The contrast sensitivity(CS)was evaluated by CSV-1000 instrument with spatial frequencies of 3,6,12,and 18 cycles/degree(c/d);the corneal higher-order aberrations(HOAs)were measured by iTrace aberration analyzer.The one-way ANOVA was performed to assess the differences between the three groups.The correlation between the change in AL and RPR was calculated by Pearson’s correlation coefficient.RESULTS:The 1-year results of 20,21,and 21 subjects in the 5-MM,5.5-MM,and 6-MM groups,respectively,were presented.There were no statistical differences in baseline age,sex,or ocular parameters between the three groups(all P>0.05).At the 1-year visit,the 5-MM group had lower axial elongation than the 6-MM group(0.07±0.09 vs 0.18±0.11 mm,P=0.001).The 5-MM group had more myopic total RPR(TRPR,P=0.014),with RPR in the 15°–30°(RPR 15–30,P=0.015),30°–45°(RPR 30–45,P=0.011),temporal(RPR-T,P=0.008),and nasal area(RPR-N,P<0.001)than the 6-MM group.RPR 15–30 in the 5.5-MM group was more myopic than that in the 6-MM group(P=0.002),and RPR-N in the 5-MM group was more myopic than that in the 5.5-MM group(P<0.001).There were positive correlations between the axial elongation and the change in TRPR(r=0.756,P<0.001),RPR 15–30(r=0.364,P=0.004),RPR 30–45(r=0.306,P=0.016),and RPR-N(r=0.253,P=0.047).The CS decreased at 3 c/d(P<0.001),and the corneal HOAs increased in the 5-MM group(P=0.030).CONCLUSION:Ortho-k with 5 mm BOZD can control myopia progression more effectively.The mechanism may be associated with greater myopic shifts in RPR.
文摘Light manipulation and control are essential in various contemporary technologies,and as these technologies evolve,the demand for miniaturized optical components increases.Planar-lens technologies,such as metasurfaces and difractive optical elements,have gained attention in recent years for their potential to dramatically reduce the thickness of traditional refractive optical systems.However,their fabrication,particularly for visible wavelengths,involves complex and costly processes,such as high-resolution lithography and dry-etching,which has limited their availability.In this study,we present a simplifed method forfabricating visible Fresnel zone plate(FZP)planar lenses,a type of diffractive optical element,using an i-line stepper and a special photoresist(color resist)that only necessitates coating,exposure,and development,eliminating the need for etching or other post-processing steps.We fabricated visible FZp lens patterns using conventional photolithography equipment on 8-inch silica glass wafers,and demonstrated focusing of 550 nm light to a diameter of 1.1μm with a focusing efficiency of 7.2%.Numerical simulations showed excellent agreement with experimental results,confirming the high precision and designability of our method.Our lenses were also able to image objects with features down to 1.1μm,showcasing their potential for practical applications in imaging.Our method is a cost-effective,simple,and scalable solution for mass production of planar lenses and other optical components operating in the visible region.It enables the development of advanced,miniaturized optical systems to meet modern technology demand,making it a valuable contribution to optical component manufacturing.
基金the National Natural Science Foundation of China(Grant No.11975004)the Key Research and Development Plan Project of Guangxi,China(Grant No.Guike AB18281007)。
文摘The development of blue semiconductor light-emitting diodes(LEDs)has produced potential applications for Prdoped materials that can absorb blue light,especially crystals,and we now report structure and optical properties for high-quality Pr-doped single crystals of yttria-stabilized zirconia(YSZ)grown by the optical floating zone(FZ)method.X-ray diffraction(XRD)and Raman spectroscopy showed that all of the single crystal samples were in the cubic phase,whereas the corresponding ceramic samples contained a mixture of monoclinic and cubic phases.X-ray photoelectron spectroscopy(XPS)and electron paramagnetic resonance(EPR)spectroscopy showed that Pr was present as the Pr^(3+)ion in ceramic rods and single crystals after heating to high temperatures.The absorption and photoluminescence excitation(PLE)spectra of the Pr-doped YSZ crystals measured at room temperature showed strong absorption of blue light,while their photoluminescence(PL)spectra showed five emission peaks at 565 nm,588 nm,614 nm,638 nm,and 716 nm under450 nm excitation.The optimum luminescence properties were obtained with the crystal prepared using 0.15 mol%Pr_(6)O_(11),and those with higher concentrations showed evidence of quenching of the luminescence properties.In addition,the color purity of Pr-doped YSZ single crystal reached 98.9%in the orange–red region.
基金Project supported by the National Key Research and Development Program of China(Grant No.2017YFA0403704)the National Natural Science Foundation of China(Grant Nos.11304113,11474127,and 11574112)the Fundamental Research Funds for the Central Universities of China
文摘Columbite Zn0.8Co0.2Nb2O6 crystals were grown by optical floating zone methods. The x-ray diffraction(XRD) was used to check the structure information of the grown Zn0.8Co0.2Nb2O6 crystal. The room temperature and temperature-dependent Raman spectra were tested to investigate the optical phonon behaviors of columbite Zn0.8Co0.2Nb2O6, which exhibited a temperature stable property. The magnetics properties of Zn0.8Co0.2Nb2O6, measured by a physical property measurement system(PPMS), were also presented in this work.
基金supported by Capital’s Funds for Health Improvement and Research(Grant No.2022-1G-4083)the National Natural Science Foundation of China(Grant No.82171092)the National Key R&D Program of China(Grant Nos.2021YFC2702100 and 2020YFC2008200).
文摘Background To investigate the control effect on the axial length elongation using corneal refractive therapy(CRT)with different optical zone diameters(BOZDs).We also sought to compare the difference in higher-order aberrations(HOAs),treatment zone(TZ)size and Zernike defocus coefficient with different BOZDs and seek the optimal parameter for predicting axial elongation.Methods This prospective cohort study included 7-to 14-year-olds fitted with orthokeratology(ortho-K)lenses of 5-mm(5-mm group)or 6-mm BOZD(6-mm group).Axial length(AL),corneal topography,HOAs and Zernike defocus coefficient were obtained at baseline,and 1,3,6,9 and 12 months follow-up visits.Multivariate regression analyses were used to explore the association between AL change and ocular biometric parameters.Receiver operating characteristic(ROC)curve analysis was used to determine the best diagnostic value for AL change in ocular biometric parameters.Results In total,301 participants completed the one-year follow-up.The mean AL change in the 5-mm group(0.13±0.18 mm)was less than that in the 6-mm group(0.27±0.15 mm)at the 12 months visit.The TZ size and decentration were smaller,while the Zernike defocus coefficient and HOAs were higher in the 5-mm group(all P<0.05).Older age and smaller TZ size were protective factors against AL elongation in multiple regression.In predicting AL elongation,TZ diameter yielded an area under the ROC curve of 0.684 with a cut-off value of 3.82 mm.Conclusion The 5-mm group showed 0.14 mm(51.8%)less axial elongation than the 6-mm group.The 5-mm BOZD produced a smaller TZ size,higher Zernike defocus coefficient and higher HOA after reshaping of the cornea.TZ size was the best predictor of AL elongation.TZ diameter less than 3.82 mm may lead to AL elongation less than 0.2 mm in one year.
基金Project supported by the National Natural Science Foundations of China (11975004,12175047)the Key Research and Development Plan Project of Guangxi,China (Guike AB18281007)。
文摘A series of high quality Dy_(2)O_(3) and Tm_(2)O_(3)co-doped yttria stabilized zirconia(YSZ) single crystals was synthesized.These crystals have a single cubic structure,and exhibit the characteristic of Dy^(3+)(blue and yellow emissions) and Tm^(3+)(blue emission) under excitation with NUV light.Impo rtantly,the hue can be varied between blue and white by modifying the Tm^(3+)/Dy^(3+)ratio.The photoluminescence and decay curves are consistent with the existence of resonance-type energy transfer from Tm^(3+)to Dy^(3+)ions via an electric multipole interaction mechanism.Maximum luminescence intensity is observed in YSZ doped with 0.50 mol% Tm_(2)O_(3) and 0.75 mol% Dy_(2)O_(3),and this sample has CIE coordinates(x = 0.33,y = 0.33) in accordance with those for white chromaticity.Thus,the outstanding luminescence properties of these single crystals suggest potential applications in white light emission devices.