This paper concludes the case study work on the optical sensor, which is a new method for voltage and current measurement. Fiber Bragg gratings (FBG) have been developed and used for decades in the telecommunication i...This paper concludes the case study work on the optical sensor, which is a new method for voltage and current measurement. Fiber Bragg gratings (FBG) have been developed and used for decades in the telecommunication industry. In recent years, FBG sensors have found wide applications in monitoring strain, temperature, voltage and current across all industries. As the process of constructing a robust smart grid, thousands of miles of optical-fibers have been deployed along the power transmission lines for the purpose of power production communication. This paper focuses on using the power optical fiber as voltage/current sensors instead of those copper wired traditional current transformers. By using piezoelectric layers, the optical sensor is able to transform voltage/current magnitude into optical signal, as well as transmit the signal through the optical fiber. The application of using optical fiber will significantly reduce the cost of deploying traditional current transformers all around the power grid. Moreover, the optical sensor is more stable, more accurate and faster, with such characteristics, the smart grid monitoring system could be much better. The application of combining the optical composite low-voltage cable (OPLC) and the optical current sensor in the distribution network for smart distribution monitoring has been analyzed.展开更多
In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,t...In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,the characteristics of hollow-cathode discharge and electron beam characterization under pulsed high voltage drive are studied experimentally and discussed by discharge characteristics and analyses of waveform details,respectively.The validation experiments indicate that the pulsed high voltage supply significantly improves the frequency and stability of the discharge,which provides a new solution for the realization of a high-frequency,high-energy electron beam source.The peak current amplitude in the high-energy electron beam increases from 6.2 A to 79.6 A,which indicates the pulsed power mode significantly improves the electron beam performance.Besides,increasing the capacitance significantly affects the highcurrent,lower-energy electron beam more than the high-energy electron beam.展开更多
This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The desi...This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request.展开更多
Abstract: The current measuring principle, the hardware structure and the software functions of a high voltage breaker current monitoring and fault diagnosis system are introduced. A simple algorithm for calculating t...Abstract: The current measuring principle, the hardware structure and the software functions of a high voltage breaker current monitoring and fault diagnosis system are introduced. A simple algorithm for calculating the current effective value is given. The cut - off characteristics of the breaker are classified. This system can provide a foundation for reasonably determining the breaker service period.展开更多
A research on passive optical fiber current sensor based on magneto-optical crystal and a new design of light path of the sensor head are presented. Both methods of dual-channel optical detection of the polarization s...A research on passive optical fiber current sensor based on magneto-optical crystal and a new design of light path of the sensor head are presented. Both methods of dual-channel optical detection of the polarization state of the output light and signal processing are proposed. Signal processing can obtain the linear output of the current measurement of the wire more conveniently. Theoretical analysis on the magnetooptical fiber current sensor is given, followed by experiments. After that, further analysis is made according to the results, which leads to clarifying the exiting problems and their placements.展开更多
A high performance current and voltage measurement system has been developed in power system. The system is composed of two parts: one current measurement element and one voltage measurement element. A Rogowski coil ...A high performance current and voltage measurement system has been developed in power system. The system is composed of two parts: one current measurement element and one voltage measurement element. A Rogowski coil and a capacitive voltage divider are used respectively for the line current and voltage measurements. Active electronic components are used to modulate signal, and power supply for these components is drawn from power line via an auxiliary current transformer. Measurement signal is transmitted by optical fibers, which is resistant to electromagnetic induction and noise. With careful design and the use of digital signal processing technology, the whole system can meet 0.5% accuracy for metering and provides large dynamic range coupled with good accuracy for protective relaying use.展开更多
A novel Cu(I) complex with the formula of [Cu(DPEphos)(Dicnq)]BF4(CuDD) was synthesized and characterized by X-ray single crystal diffraction method,in which DPEphos and Dicnq denote bis[2-(diphenylphosphino)phenyl]et...A novel Cu(I) complex with the formula of [Cu(DPEphos)(Dicnq)]BF4(CuDD) was synthesized and characterized by X-ray single crystal diffraction method,in which DPEphos and Dicnq denote bis[2-(diphenylphosphino)phenyl]ether and 6,7-Dicyanodipyrido[2,2-d:2 ,3 -f] quinoxaline,respectively.Organic ultraviolet optical sensor based on photovoltaic diode is fabricated by using CuDD as an electron acceptor and 4,4′,4″-tris-(2-methylphenyl phenylamino) triphenylamine(m-MTDATA) as an electron donor.The sensor is sensit...展开更多
Current--voltage measurements obtained from lead zirconate titanate/nickel bilayered hollow cylindrical magnetoelectric composite showed that a sinusoidal current applied to the copper coil wrapped around the hollow c...Current--voltage measurements obtained from lead zirconate titanate/nickel bilayered hollow cylindrical magnetoelectric composite showed that a sinusoidal current applied to the copper coil wrapped around the hollow cylinder circumference induces voltage across the lead zirconate titanate layer thickness. The current--voltage coefficient and the maximum induced voltage in lead zirconate titanate at 1~kHz and resonance (60.1~kHz) frequencies increased linearly with the number of the coil turns and the applied current. The resonance frequency corresponds to the electromechanical resonance frequency. The current--voltage coefficient can be significantly improved by optimizing the magnetoelectric structure geometry and/or increasing the number of coil turns. Hollow cylindrical lead zirconate titanate/nickel structures can be potentially used as current sensors.展开更多
The pressure distribution in an arcing chamber is critically important for the SF6 puffer circuit breaker design. In this paper, the pressure variation of four locations in the nozzle was measured by piezoresistive an...The pressure distribution in an arcing chamber is critically important for the SF6 puffer circuit breaker design. In this paper, the pressure variation of four locations in the nozzle was measured by piezoresistive and fiber optical pressure sensors at two current levels of 10 kA and 50 kA. An arc voltage measurement was also taken. The results demonstrate that using either type of sensor with a connecting tube is able to detect the fast pressure variation in circuit breakers, however the possible distortion and delay to the pressure transient caused by the tube need further study.展开更多
The Allan variance analysis method is used to identify the stochastic noise in the stray current sensor. The stray current characteristic is firstly introduced. Then the optical configuration and the signal processing...The Allan variance analysis method is used to identify the stochastic noise in the stray current sensor. The stray current characteristic is firstly introduced. Then the optical configuration and the signal processing method of the stray current sensor are illustrated. Moreover, the cause of the stochastic noise in the stray current sensor is analyzed. The calculation method of the stochastic noise coefficient is presented in detail. And the feasibility of the stochastic noise identification with the Allan variance analysis method is evaluated. Furthermore, the zero-drift signal acquisition experiment is conducted to identify the stochastic noise in the stray current sensor. According to the experimental result, the bias instability noise, the quantization noise and the white noise are identified as the major stochastic noise. Finally, the experiment on the direct-current signal acquisitions is conducted, whose results indicate that the signal drift of the measured direct-current is mainly caused by the major stochastic noise. And the suppression methods of the major stochastic noise are proposed.展开更多
The article describes design peculiarities of the novel compact vacuum circuit breaker with rated voltage 40.5 kV. The design incorporates several novel technical solutions: polycarbonate support insulation, mono-sta...The article describes design peculiarities of the novel compact vacuum circuit breaker with rated voltage 40.5 kV. The design incorporates several novel technical solutions: polycarbonate support insulation, mono-stable magnetic actuator, labyrinth pulling insulator, core-type flexible contact and new compact vacuum interrupter (VI). Phases are encapsulated into silicone rubber providing required creepage distance and excellent tracking resistance. These novelties along with extensive modeling of the mechanical and electrical fields followed by design optimization resulted in weight reduction of more than 50% compared with alternatives available in the market. And this is in spite of built in sensors measuring: phase currents, zero-sequence current, phase voltages.展开更多
The factors influencing the current-voltage(I-V) characteristics of light-emitting diodes(LEDs) are investigated to reveal the connection of I-V characteristics under optical excitation and those under electrical ...The factors influencing the current-voltage(I-V) characteristics of light-emitting diodes(LEDs) are investigated to reveal the connection of I-V characteristics under optical excitation and those under electrical excitation.By inspecting the I-V curves under optical and electrical excitation at identical injection current,it has been found that the I-V curves exhibit apparent differences in voltage values.Furthermore,the differences are found to originate from the junction temperatures in diverse excitation ways.Experimental results indicate that if the thermal effect of illuminating spot is depressed to an ignorable extent by using pulsed light,the junction temperature will hardly deflect from that under optical excitation,and then the I-V characteristics under two diverse excitation ways will be the same.展开更多
文摘This paper concludes the case study work on the optical sensor, which is a new method for voltage and current measurement. Fiber Bragg gratings (FBG) have been developed and used for decades in the telecommunication industry. In recent years, FBG sensors have found wide applications in monitoring strain, temperature, voltage and current across all industries. As the process of constructing a robust smart grid, thousands of miles of optical-fibers have been deployed along the power transmission lines for the purpose of power production communication. This paper focuses on using the power optical fiber as voltage/current sensors instead of those copper wired traditional current transformers. By using piezoelectric layers, the optical sensor is able to transform voltage/current magnitude into optical signal, as well as transmit the signal through the optical fiber. The application of using optical fiber will significantly reduce the cost of deploying traditional current transformers all around the power grid. Moreover, the optical sensor is more stable, more accurate and faster, with such characteristics, the smart grid monitoring system could be much better. The application of combining the optical composite low-voltage cable (OPLC) and the optical current sensor in the distribution network for smart distribution monitoring has been analyzed.
基金supported by National Natural Science Foundation of China(No.12102099)the National Key R&D Program of China(No.2021YFC2202700)the Outstanding Academic Leader Project of Shanghai(Youth)(No.23XD1421700),respectively。
文摘In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,the characteristics of hollow-cathode discharge and electron beam characterization under pulsed high voltage drive are studied experimentally and discussed by discharge characteristics and analyses of waveform details,respectively.The validation experiments indicate that the pulsed high voltage supply significantly improves the frequency and stability of the discharge,which provides a new solution for the realization of a high-frequency,high-energy electron beam source.The peak current amplitude in the high-energy electron beam increases from 6.2 A to 79.6 A,which indicates the pulsed power mode significantly improves the electron beam performance.Besides,increasing the capacitance significantly affects the highcurrent,lower-energy electron beam more than the high-energy electron beam.
基金Project supported by the National Natural Science Foundation of China (Grant No.50447006)
文摘This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request.
文摘Abstract: The current measuring principle, the hardware structure and the software functions of a high voltage breaker current monitoring and fault diagnosis system are introduced. A simple algorithm for calculating the current effective value is given. The cut - off characteristics of the breaker are classified. This system can provide a foundation for reasonably determining the breaker service period.
文摘A research on passive optical fiber current sensor based on magneto-optical crystal and a new design of light path of the sensor head are presented. Both methods of dual-channel optical detection of the polarization state of the output light and signal processing are proposed. Signal processing can obtain the linear output of the current measurement of the wire more conveniently. Theoretical analysis on the magnetooptical fiber current sensor is given, followed by experiments. After that, further analysis is made according to the results, which leads to clarifying the exiting problems and their placements.
文摘A high performance current and voltage measurement system has been developed in power system. The system is composed of two parts: one current measurement element and one voltage measurement element. A Rogowski coil and a capacitive voltage divider are used respectively for the line current and voltage measurements. Active electronic components are used to modulate signal, and power supply for these components is drawn from power line via an auxiliary current transformer. Measurement signal is transmitted by optical fibers, which is resistant to electromagnetic induction and noise. With careful design and the use of digital signal processing technology, the whole system can meet 0.5% accuracy for metering and provides large dynamic range coupled with good accuracy for protective relaying use.
基金supported by the Natural Science Foundationof Jilin Province (No.20060516)the Doctoral Foundation of JilinNormal University (No.2006006 and No.2007009)the Subject and Base Construction Foundation of Jilin Normal University (No.2006041)
文摘A novel Cu(I) complex with the formula of [Cu(DPEphos)(Dicnq)]BF4(CuDD) was synthesized and characterized by X-ray single crystal diffraction method,in which DPEphos and Dicnq denote bis[2-(diphenylphosphino)phenyl]ether and 6,7-Dicyanodipyrido[2,2-d:2 ,3 -f] quinoxaline,respectively.Organic ultraviolet optical sensor based on photovoltaic diode is fabricated by using CuDD as an electron acceptor and 4,4′,4″-tris-(2-methylphenyl phenylamino) triphenylamine(m-MTDATA) as an electron donor.The sensor is sensit...
基金supported by the National Natural Science Foundation of China (Grant Nos. 50572006, 50802008 and 50874010)the Natural Science Foundation of Beijing, China (Grant No. 2073026)+2 种基金the Program for New Century Excellent Talents in University(Grant No. 20060420152)Scholars and Innovative Research Team in University (Grant No. 0509)Alex A. Volinsky wouldlike to acknowledge support from NSF (Grant No. CMMI-0600266)
文摘Current--voltage measurements obtained from lead zirconate titanate/nickel bilayered hollow cylindrical magnetoelectric composite showed that a sinusoidal current applied to the copper coil wrapped around the hollow cylinder circumference induces voltage across the lead zirconate titanate layer thickness. The current--voltage coefficient and the maximum induced voltage in lead zirconate titanate at 1~kHz and resonance (60.1~kHz) frequencies increased linearly with the number of the coil turns and the applied current. The resonance frequency corresponds to the electromechanical resonance frequency. The current--voltage coefficient can be significantly improved by optimizing the magnetoelectric structure geometry and/or increasing the number of coil turns. Hollow cylindrical lead zirconate titanate/nickel structures can be potentially used as current sensors.
文摘The pressure distribution in an arcing chamber is critically important for the SF6 puffer circuit breaker design. In this paper, the pressure variation of four locations in the nozzle was measured by piezoresistive and fiber optical pressure sensors at two current levels of 10 kA and 50 kA. An arc voltage measurement was also taken. The results demonstrate that using either type of sensor with a connecting tube is able to detect the fast pressure variation in circuit breakers, however the possible distortion and delay to the pressure transient caused by the tube need further study.
基金Project(2017QNA13)supported by Fundamental Research Funds for the Central Universities,ChinaProject(PAPD)supported by Priority Academic Program Development of Jiangsu Higher Education Institutions,China
文摘The Allan variance analysis method is used to identify the stochastic noise in the stray current sensor. The stray current characteristic is firstly introduced. Then the optical configuration and the signal processing method of the stray current sensor are illustrated. Moreover, the cause of the stochastic noise in the stray current sensor is analyzed. The calculation method of the stochastic noise coefficient is presented in detail. And the feasibility of the stochastic noise identification with the Allan variance analysis method is evaluated. Furthermore, the zero-drift signal acquisition experiment is conducted to identify the stochastic noise in the stray current sensor. According to the experimental result, the bias instability noise, the quantization noise and the white noise are identified as the major stochastic noise. Finally, the experiment on the direct-current signal acquisitions is conducted, whose results indicate that the signal drift of the measured direct-current is mainly caused by the major stochastic noise. And the suppression methods of the major stochastic noise are proposed.
文摘The article describes design peculiarities of the novel compact vacuum circuit breaker with rated voltage 40.5 kV. The design incorporates several novel technical solutions: polycarbonate support insulation, mono-stable magnetic actuator, labyrinth pulling insulator, core-type flexible contact and new compact vacuum interrupter (VI). Phases are encapsulated into silicone rubber providing required creepage distance and excellent tracking resistance. These novelties along with extensive modeling of the mechanical and electrical fields followed by design optimization resulted in weight reduction of more than 50% compared with alternatives available in the market. And this is in spite of built in sensors measuring: phase currents, zero-sequence current, phase voltages.
基金Project supported by the National Natural Science Foundation of China(No.61006053)the National Science Foundation ofCQ CSTC (No.CSTC 2008BB3156)
文摘The factors influencing the current-voltage(I-V) characteristics of light-emitting diodes(LEDs) are investigated to reveal the connection of I-V characteristics under optical excitation and those under electrical excitation.By inspecting the I-V curves under optical and electrical excitation at identical injection current,it has been found that the I-V curves exhibit apparent differences in voltage values.Furthermore,the differences are found to originate from the junction temperatures in diverse excitation ways.Experimental results indicate that if the thermal effect of illuminating spot is depressed to an ignorable extent by using pulsed light,the junction temperature will hardly deflect from that under optical excitation,and then the I-V characteristics under two diverse excitation ways will be the same.