期刊文献+
共找到115篇文章
< 1 2 6 >
每页显示 20 50 100
Study on the operating characteristics of Stirling engine based on an optimized analysis method 被引量:1
1
作者 Shang-Dong Yang Wen-Pei Feng +1 位作者 Yu-Gao Ma Zhi-Xing Gu 《Nuclear Science and Techniques》 2025年第9期209-225,共17页
The Stirling engine,as a closed-cycle power machine,exhibits excellent emission characteristics and broad energy adaptability.Second-order analysis methods are extensively used during the foundational design and therm... The Stirling engine,as a closed-cycle power machine,exhibits excellent emission characteristics and broad energy adaptability.Second-order analysis methods are extensively used during the foundational design and thermodynamic examination of Stirling engines,owing to their commendable model precision and remarkable efficiency.To scrutinize the effect of Stirling engine design parameters on the cyclical work output and efficiency,this study formulates a series of differential equations for the Stirling cycle by employing second-order analysis methods,subsequently augmenting the predictive accuracy by integrating considerations of loss mechanisms.In addition,an iterative method for the convergence of the average pressure was introduced.The predictive capability of the established model was validated using GPU-3 and RE-1000 experimental data.According to the model,parameters such as the operational fluid,porosity of the regenerator,and diameter of the wire mesh and their influence on the resulting work output and cyclic efficiency of the Stirling engine were analyzed,thereby facilitating a broader understanding of the engine's functional characteristics.These findings suggest that hydrogen,owing to its lower dynamic viscosity coefficient,can provide superior output power.The loss due to flow resistance tends to increase with the rotational speed.Additionally,under conditions of elevated rotational speed,the loss from flow resistance declines in cases of increased porosity,and the enhancement of the porosity to diminish flow resistance losses can boost both the output work and the cyclic efficiency of the engine.As the porosity increased further,the hydraulic diameter and dead volume in the regenerator continued to expand,causing the pressure drop within the engine to become the dominant factor in the gradual reduction of output power.Furthermore,extending the length of the regenerator results in a decrease in the output work,although the thermal cycle efficiency initially increases before eventually decreasing.Based on these insights,this study pursues the optimal designs for Stirling engines. 展开更多
关键词 Stirling engine Second-order method operating characteristics Mechanisms of loss Cyclic efficiency
在线阅读 下载PDF
Optimal Receiver Operating Characteristic Curve of Classical Conditional Power under Normal Models
2
作者 ZHANG Ying-Ying 《应用概率统计》 北大核心 2025年第2期277-304,共28页
A Receiver Operating Characteristic(ROC)analysis of a power is important and useful in clinical trials.A Classical Conditional Power(CCP)is a probability of a classical rejection region given values of true treatment ... A Receiver Operating Characteristic(ROC)analysis of a power is important and useful in clinical trials.A Classical Conditional Power(CCP)is a probability of a classical rejection region given values of true treatment effect and interim result.For hypotheses and reversed hypotheses under normal models,we obtain analytical expressions of the ROC curves of the CCP,find optimal ROC curves of the CCP,investigate the superiority of the ROC curves of the CCP,calculate critical values of the False Positive Rate(FPR),True Positive Rate(TPR),and cutoff of the optimal CCP,and give go/no go decisions at the interim of the optimal CCP.In addition,extensive numerical experiments are carried out to exemplify our theoretical results.Finally,a real data example is performed to illustrate the go/no go decisions of the optimal CCP. 展开更多
关键词 area under the curve(AUC) classical conditional power(CCP) go/no go decisions historical and interim data receiver operating characteristic(ROC)curve
在线阅读 下载PDF
Using receiver operating characteristic curves to evaluate the diagnostic value of the combination of multislice spiral CT and alpha-fetoprotein levels for small hepatocellular carcinoma in cirrhotic patients 被引量:31
3
作者 Guang-Sheng Jia Guang-Long Feng +5 位作者 Jin-Ping Li Hai-Long Xu Hui Wang Yi-Peng Cheng Lin-Lin Yan Hui-Jie Jiang 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2017年第3期303-309,共7页
BACKGROUND: The various combination of multiphase enhancement multislice spiral CT (MSCT) makes the diagno- sis of a small hepatocellular carcinoma (sHCC) on the back- ground of liver cirrhosis possible. This stu... BACKGROUND: The various combination of multiphase enhancement multislice spiral CT (MSCT) makes the diagno- sis of a small hepatocellular carcinoma (sHCC) on the back- ground of liver cirrhosis possible. This study was to explore whether the combination of MSCT enhancement scan and alpha-fetoprotein (AFP) level ficiency for sHCC. could increase the diagnostic ef- METHODS: This study included 35 sHCC patients and 52 cir- rhotic patients without image evidence of HCC as a control group. The diagnoses were made by three radiologists em- ploying a 5-point rating scale, with postoperative pathologic results as the gold standard. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diag- nostic value of the three MSCT combination modes (arterial phase+portal-venous phase, arterial phase+delayed phase, arterial phase+portal-venous phase+delayed phase) and AFP levels for sHCC on the background of liver cirrhosis. RESULTS: The area under ROC curve (AUC), sensitivity, and specificity of the combination of arterial phase+portal- venous phase+delayed phase were 0.93, 93%, and 82%, respectively. The average AUC of the arterial phase+portal- venous phase+delayed phase combination was significantly greater than that of the arterial phase+portal-venous phase (AUC=0.84, P=0.01) and arterial phase+delayed phase (AUC=0.85, P=0.03). Arterial phase+portal-venous phase had a smaller AUC (0.84) than arterial phase+delayed phase (0.85), but the difference was insignificant (P=0.15). After combining MSCT enhancement scan with AFP, the AUC, sensitivity, and specificity were 0.95, 94%, and 83%, respectively, indicating a greatly increased diagnostic efficiency for sHCC. CONCLUSIONS: The combination of AFP and 3 phases MSCT enhancement scan could increase the diagnostic efficiency for sHCC on the background of liver cirrhosis. The application of ROC curve analysis has provided a new method and reference in HCC diagnosis. 展开更多
关键词 hepatocellular carcinoma receiver operating characteristic multi-slice spiral CT ALPHA-FETOPROTEIN delayed phase imaging
暂未订购
Prediction of Abdominal Visceral Obesity From Body Mass Index,Waist Circumference and Waist-hip Ratio in Chinese Adults:Receiver Operating Characteristic Curves Analysis 被引量:55
4
作者 WEI-PINGJIA JUN-XILU +3 位作者 KUN-SANXIANG Yu-QIANBAO HUI-JUANLU ANDLEICHEN 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2003年第3期206-211,共6页
Objective To evaluate the sensitivity and specificity of body mass index (BMI), waist circumference (WC) and waist-to-hip ratio (WHR) measurements in diagnosing abdominal visceral obesity. Methods BMI, WC, and WHR wer... Objective To evaluate the sensitivity and specificity of body mass index (BMI), waist circumference (WC) and waist-to-hip ratio (WHR) measurements in diagnosing abdominal visceral obesity. Methods BMI, WC, and WHR were assessed in 690 Chinese adults (305 men and 385 women) and compared with magnetic resonance imaging (MRI) measurements of abdominal visceral adipose tissue (VA). Receiver operating characteristic (ROC) curves were generated and used to determine the threshold point for each anthropometric parameter. Results 1) MRI showed that 61.7% of overweight/obese individuals (BMI≥25 kg/m2) and 14.2% of normal weight (BMI<25 kg/m2) individuals had abdominal visceral obesity (VA≥100 cm2). 2) VA was positively correlated with each anthropometric variable, of which WC showed the highest correlation (r=0.73-0.77, P<0.001). 3) The best cut-off points for assessing abdominal visceral obesity were as followed: BMI of 26 kg/m2, WC of 90 cm, and WHR of 0.93, with WC being the most sensitive and specific factor. 4) Among subjects with BMI≥28 kg/m2 or WC≥95 cm, 95% of men and 90% of women appeared to have abdominal visceral obesity. Conclusion Measurements of BMI, WC, and WHR can be used in the prediction of abdominal visceral obesity, of which WC was the one with better accuracy. 展开更多
关键词 Body mass index (BMI) Abdominal visceral fat Anthropometric parameters Receiver operating characteristic (ROC) curves
暂未订购
Determination of the diagnostic value of the resazurin reduction assay for evaluating boar semen by receiver operating characteristic analysis
5
作者 Petra Zrimsek Marjan Kosec Janez Kunc Janko Mrkun 《Asian Journal of Andrology》 SCIE CAS CSCD 2006年第3期343-348,共6页
Aim: To assess that metabolic status of spermatozoa could provide a useful tool for evaluation of semen quality. Methods: The accuracy of the spectrophotometric application of the resazurin reduction assay was asses... Aim: To assess that metabolic status of spermatozoa could provide a useful tool for evaluation of semen quality. Methods: The accuracy of the spectrophotometric application of the resazurin reduction assay was assessed using receiver operating characteristic (ROC) analysis. Results: Areas under ROC curves (AUC) for motile sperm concentration and sperm index (SI) (sperm concentration multiplied by the square root of percentage sperm motility multiplied by the percentage normal sperm morphology) were 0.922. The best discrimination between poor and good semen samples according to the SI was achieved at a cut-off point of A610 = 0.209, where high sensitivity (94.1%) and specificity (91.7%) were calculated. The assay was less accurate when motile sperm concentration was used as the criterion value, yielding sensitivity of 88.2% and specificity of 87.5%, respectively. Likelihood ratios (LR) indicate that absorbances lower than 0.209 were at least 11.3 times as likely to be found in good semen samples than those in poor according to the SI, whereas in the case of motile sperm concentration, the LR was calculated to be 7.06. Conclusion: These results show that the resazurin reduction assay combined with spectrophotometry is an accurate method of assessing the quality of boar semen. 展开更多
关键词 resazurin reduction assay SEMEN PORCINE receiver operating characteristic analysis cut-off point selection
暂未订购
Study on Diagnosis Criteria of Fire-Heat Syndrome Based on Receiver Operating Characteristic Curve and Principal Component Analysis
6
作者 刘四军 黄兆胜 +7 位作者 吴庆光 黄张杰 吴丽蓉 闫文丽 王奇 王宗伟 张伦博 杨政 《Chinese Journal of Integrative Medicine》 SCIE CAS CSCD 2016年第4期258-266,共9页
Objective: To establish the diagnostic quantitative criteria for fire-heat syndrome (FHS) of Chinese medicine (CM) based on the receiver operating characteristic (ROC) curve and principal component analysis (... Objective: To establish the diagnostic quantitative criteria for fire-heat syndrome (FHS) of Chinese medicine (CM) based on the receiver operating characteristic (ROC) curve and principal component analysis (PCA). Methods: The symptoms and signs of FHS cases and healthy subjects from Guangzhou, Henan and Hunan of China were collected through questionnaire, and the diagnostic quantitative score tables were established for the three regions, respectively, with the method of maximum likelihood analysis. The homogeneity test was then performed on the diagnostic score tables for the three regions with ROC curve, and the diagnostic efficiency of diagnostic score tables for the three regions was compared with the prospective test and retrospective test. The method of PCA was adopted to obtain the analysis matrix for classifying the tapes of FHS. Results: Twenty-seven elements of FHS were confirmed through Chi-square test, and the diagnostic score tables for the three regions were established with the method of maximum likelihood analysis on the basis of the collected case data. According to the ROC curve test, the areas under ROC curve of Guangzhou diagnostic score table assessment with candidates in Guangzhou, Henan and Hunan were 0.998, 0.961 and 0.956, respectively. It showed that the diagnostic efficiency of Guangzhou diagnostic score tables was the highest one. With the prospective test, the area under ROC of Guangzhou diagnostic score table was 0.949, and more than any other diagnostic score table. By PCA, FHS was classified into excess fire and deficiency fire, and then classified into syndrome of flaring up of Heart (Xin) fire, syndrome of Lung (Fei)-Stomach (Wei) excess fire, syndrome of deficiency of Liver (Gan)-yin and Kidney (Shen)-yin, and syndrome of deficiency of Lung-yin from the view of viscera. In the retrospective test, the consistency with clinicians' diagnosis was 69.4%, and in the prospective test, it was 70.1%. Conclusions: The Guangzhou diagnostic score table could be used as the recommended criteria for the diagnosis of FHS. The classification of FHS was basically in conformity with the clinical situation. 展开更多
关键词 receiver operating characteristic curve principal component analysis diagnostic criteria fire-heatsyndrome Chinese medicine
原文传递
Receiver operating characteristic curve analysis for image quality in the detection of solitary pulmonary nodules on high resolution paper prints versus dry laser film
7
作者 HU Xiao-yun FANG Xiang-ming +6 位作者 CAO Yang HU Chun-hong YAO Xuan-jun CHEN Hong-wei HU Su SHAO Ling HU Gang-feng 《Chinese Medical Journal》 SCIE CAS CSCD 2013年第7期1378-1380,共3页
Along with the development of digital X-ray imaging technology, a new, economical and practicalpaper-based output system gradually emerged. To reduce cost, more and more radiologic institutions began to change from fi... Along with the development of digital X-ray imaging technology, a new, economical and practicalpaper-based output system gradually emerged. To reduce cost, more and more radiologic institutions began to change from film copies to lower-priced paper prints for documenting radiologic findings.Therefore, laser paper printers are frequently used as an alternative to duplicating film though the use of printed images is not yet widespread. The aim of this study was to compare the practical value of high-resolution paper printer with dry film copies for detecting small solitary pulmonary nodules (SPNs). 展开更多
关键词 receiver operating characteristic paper printer solitary pulmonary nodule dry laser printer
原文传递
A radiomics approach for predicting gait freezing in Parkinson's disease based on resting-state functional magnetic resonance imaging indices:A cross-sectional study
8
作者 Miaoran Guo Hu Liu +6 位作者 Long Gao Hongmei Yu Yan Ren Yingmei Li Huaguang Yang Chenghao Cao Guoguang Fan 《Neural Regeneration Research》 2026年第4期1621-1627,共7页
Freezing of gait is a significant and debilitating motor symptom often observed in individuals with Parkinson's disease.Resting-state functional magnetic resonance imaging,along with its multi-level feature indice... Freezing of gait is a significant and debilitating motor symptom often observed in individuals with Parkinson's disease.Resting-state functional magnetic resonance imaging,along with its multi-level feature indices,has provided a fresh perspective and valuable insight into the study of freezing of gait in Parkinson's disease.It has been revealed that Parkinson's disease is accompanied by widespread irregularities in inherent brain network activity.However,the effective integration of the multi-level indices of resting-state functional magnetic resonance imaging into clinical settings for the diagnosis of freezing of gait in Parkinson's disease remains a challenge.Although previous studies have demonstrated that radiomics can extract optimal features as biomarkers to identify or predict diseases,a knowledge gap still exists in the field of freezing of gait in Parkinson's disease.This cross-sectional study aimed to evaluate the ability of radiomics features based on multi-level indices of resting-state functional magnetic resonance imaging,along with clinical features,to distinguish between Parkinson's disease patients with and without freezing of gait.We recruited 28 patients with Parkinson's disease who had freezing of gait(15 men and 13 women,average age 63 years)and 30 patients with Parkinson's disease who had no freezing of gait(16 men and 14 women,average age 64 years).Magnetic resonance imaging scans were obtained using a 3.0T scanner to extract the mean amplitude of low-frequency fluctuations,mean regional homogeneity,and degree centrality.Neurological and clinical characteristics were also evaluated.We used the least absolute shrinkage and selection operator algorithm to extract features and established feedforward neural network models based solely on resting-state functional magnetic resonance imaging indicators.We then performed predictive analysis of three distinct groups based on resting-state functional magnetic resonance imaging indicators indicators combined with clinical features.Subsequently,we conducted 100 additional five-fold cross-validations to determine the most effective model for each classification task and evaluated the performance of the model using the area under the receiver operating characteristic curve.The results showed that when differentiating patients with Parkinson's disease who had freezing of gait from those who did not have freezing of gait,or from healthy controls,the models using only the mean regional homogeneity values achieved the highest area under the receiver operating characteristic curve values of 0.750(with an accuracy of 70.9%)and 0.759(with an accuracy of 65.3%),respectively.When classifying patients with Parkinson's disease who had freezing of gait from those who had no freezing of gait,the model using the mean amplitude of low-frequency fluctuation values combined with two clinical features achieved the highest area under the receiver operating characteristic curve of 0.847(with an accuracy of 74.3%).The most significant features for patients with Parkinson's disease who had freezing of gait were amplitude of low-frequency fluctuation alterations in the left parahippocampal gyrus and two clinical characteristics:Montreal Cognitive Assessment and Hamilton Depression Scale scores.Our findings suggest that radiomics features derived from resting-state functional magnetic resonance imaging indices and clinical information can serve as valuable indices for the identification of freezing of gait in Parkinson's disease. 展开更多
关键词 amplitude of low-frequency fluctuation degree centrality feedforward neural network freezing of gait machine learning parahippocampal gyrus Parkinson's disease receiver operating characteristic regional homogeneity resting-state functional magnetic resonance imaging
暂未订购
Alternate operation characteristics of a solar-ground source heat pump system 被引量:4
9
作者 杨卫波 陈振乾 施明恒 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期327-332,共6页
In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model wi... In order to investigate the alternate operation characteristics of a solar-ground source heat pump system(SGSHPS),various alternate operation modes are put forward and defined.A two-dimensional mathematical model with freezing/melting phase changes is developed for the heat transfer analysis of the soil.Based on the numerical solution of the model,the variation trends of underground soil temperature of the SGSHPS operated in various alternate operation modes are discussed.The results indicate that,for the day-night and short-time interval alternate operation modes without solar energy,the operation time fraction of a solar heat source should be confined to from 50% to 58% when operated in an alternate period of 24 h.Meanwhile,the disadvantages of a natural resumption of soil temperature can be overcome effectively by solar energy filling,and an optimal operation effect can be achieved by integrating the mode of solar energy filling with other alternate modes.In addition,the accuracy of the presented model is verified by the experimental data of borehole wall temperatures.The conclusions can provide a reference for the optimization operation of the SGSHPS. 展开更多
关键词 solar-ground source heat pump alternate operation characteristics numerical simulation experimental validation
在线阅读 下载PDF
Nomogram for predicting lymph node metastasis rate of submucosal gastric cancer by analyzing clinicopathological characteristics associated with lymph node metastasis 被引量:2
10
作者 Zhixue Zheng Yinan Zhang +6 位作者 Lianhai Zhang Ziyu Li Aiwen Wu Xiaojiang Wu Yiqiang Liu Zhaode Bu Jiafu Ji 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2015年第6期572-579,共8页
Background: To combine dinicopathological characteristics associated with lymph node metastasis for submucosal gastric cancer into a nomogram. Methods: We retrospectively analyzed 262 patients with submucosal gastri... Background: To combine dinicopathological characteristics associated with lymph node metastasis for submucosal gastric cancer into a nomogram. Methods: We retrospectively analyzed 262 patients with submucosal gastric cancer who underwent D2 gastrectomy between 1996 and 2012. The relationship between lymph node metastasis and clinicopathological features was statistically analyzed. With multivariate logistic regression analysis, we made a nomogram to predict the possibility of lymph node metastasis. Receiver operating characteristic (ROC) analysis was also performed to assess the predictive value of the model. Discrimination and calibration were performed using internal validation. Results: A total number of 48 (18.3%) patients with submucosal gastric cancer have pathologically lymph node metastasis. For submucosal gastric carcinoma, lymph node metastasis was associated with age, tumor location, macroscopic type, size, differentiation, histology, the existence of ulcer and lymphovascular invasion in univariate analysis (all P〈0.05). The multivariate logistic old, macroscopic type III or mixed, undifferentiated type, regression analysis identified that age _〈50 years and presence of lymphovascular invasion were independent risk factors of lymph node metastasis in submucosal gastric cancer (all P〈0.05). We constructed a predicting nomogram with all these factors for lymph node metastasis in submucosal gastric cancer with good discrimination [area under the curve (AUC) =0.844]. Internal validation demonstrated a good discrimination power that the actual probability corresponds closely with the predicted probability. Conclusions: We developed a nomogram to predict the rate of lymph node metastasis for submucosal gastric cancer. With good discrimination and internal validation, the nomogram improved individualized predictions for assisting clinicians to make appropriated treatment decision for submucosal gastric cancer patients. 展开更多
关键词 Endoscopic resection lymph node metastasis NOMOGRAM receiver operating characteristic (ROC) submucosal gastric cancer
暂未订购
Magnetic Field and Operating Performance Analysisof Conical-rotor Permanent Magnet Synchronous Motor 被引量:3
11
作者 Jiabao Wang Shoudao Huang +1 位作者 Chao Guo Yaojing Feng 《CES Transactions on Electrical Machines and Systems》 2018年第1期181-187,共7页
In order to accurately analyze the magnetic field of conical-rotor permanent magnet synchronous motor(CR-PMSM),the effectiveness of two methods was studied on handling of problems concerned with non-uniform distributi... In order to accurately analyze the magnetic field of conical-rotor permanent magnet synchronous motor(CR-PMSM),the effectiveness of two methods was studied on handling of problems concerned with non-uniform distribution of magnetic field along axial direction in CR-PMSM,which were sectional calculation(SC)method and three-dimensional finite element(3-D FE)method.On this basis,the influence of the axial displacement and dq-axis currents on the operating characteristics of axial magnetic force and torque is analyzed by using the 3-D FE model.Analysis results show that the axial magnetic force and torque decrease with the increase of axial displacement of the rotor,and the amplitude regularity of the axial magnetic force is affected by the d-axis current.A prototype machine is fabricated and tested,in order to validate the design theory. 展开更多
关键词 Magnetic field of conical-rotor permanent magnet synchronous motor operating characteristics non-uniform of magnetic field 3-D FE method
在线阅读 下载PDF
STUDY ON THE CHARACTERISTICS OF LOW FREQUENCY SYNCHROMOTOR USED IN MINE HOIST SYSTEMS FED BY THE CYCLOINVERTER
12
作者 杨公训 宋凌云 《Journal of China University of Mining and Technology》 1995年第1期98-105,共8页
The Low Frequency Synchromotor Drive Mine Hoist System fed by the cycloinverter has good features from the technological and economical point of view. According to the erating char acteristic of the mine hoist system,... The Low Frequency Synchromotor Drive Mine Hoist System fed by the cycloinverter has good features from the technological and economical point of view. According to the erating char acteristic of the mine hoist system, an advanced analysis is given to the construction, the operating characteristics and the harmonics of the magnetomotive force of the synchromotor fed by the cy cloinverter, and the beneficial suggestions are also given in this paper. 展开更多
关键词 cycloinverter synchromotor operating characteristic M. M. F. harmonics
在线阅读 下载PDF
Determination of the diagnostic value of the resazurin reduction assay for evaluating boar semen by receiver operating cha-racteristic analysis
13
作者 PetraZrim■ek MarjanKosec +1 位作者 JanezKunc JankoMrkun 《Asian Journal of Andrology》 SCIE CAS CSCD 2006年第A03期343-348,389,共5页
Aim:To assess that metabolic status of spermatozoa could provide a useful tool for evaluation of semen quality. Methods:The accuracy of the spectrophotometric application of the resazurm reduction assay was assessed u... Aim:To assess that metabolic status of spermatozoa could provide a useful tool for evaluation of semen quality. Methods:The accuracy of the spectrophotometric application of the resazurm reduction assay was assessed using receiver operating characteristic(ROC)analysis.Results:Areas under ROC curves(AUC)for motile sperm concen- tration and sperm index(SI)(sperm concentration multiplied by the square root of percentage sperm motility multi- plied by the percentage normal sperm morphology)were 0.922.The best discrimination between poor and good semen samples according to the SI was achieved at a cut-off point of A_(610)=0.209,where high sensitivity(94.1%)and specificity(91.7%)were calculated.The assay was less accurate when motile sperm concentration was used as the criterion value,vielding sensitivity of 88.2% and specificity of 87.5%,respectively,Likelihood ratios(LR)indicate that absorbances lower than 0.209 were at least 11.3 times as likely to be found in good semen samples than those in poor according to the SI,whereas in the case of motile sperm concentration,the LR was calculated to be 7.06.Conclusion: These results show that the resazurin reduction assay combined with spectrophotometry is an accurate method of assessing the quality of boar semen. 展开更多
关键词 resazurin reduction assay SEMEN PORCINE receiver operating characteristic analysis cut-off point selection
全文增补中
Visual Study on Flow and Operational Characteristics of Flat Plate Closed Loop Pulsating Heat Pipes 被引量:2
14
作者 杨洪海 Groll Manfred Khandekar Sameer 《Journal of Donghua University(English Edition)》 EI CAS 2009年第1期80-84,共5页
This paper presents an experimental study including visualization on a flat plate closed loop pulsating heat pipes.It consists of a total of 40 channels with square cross section(2 mm×2 mm,165 mm long) machined d... This paper presents an experimental study including visualization on a flat plate closed loop pulsating heat pipes.It consists of a total of 40 channels with square cross section(2 mm×2 mm,165 mm long) machined directly on an aluminum plate(180 mm×120 mm×3 mm) covered by a transparent plate.The working fluid employed is ethanol.As a result,various flow patterns and their transitions are observed and found to be related to the fluid fill ratio,input heat load and the device orientation.Also the operational characteristics and working mechanism are discussed. 展开更多
关键词 flat plate closed loop pulsating heat pipes fill ratio flow patterns operational characteristics
在线阅读 下载PDF
GEVREY-HYPOELLIPTICITY FOR A CLASS OF TOTALLY CHARACTERISTIC OPERATORS
15
作者 Tian Yan Zhou Di Chen Hua 《Acta Mathematica Scientia》 SCIE CSCD 2000年第1期79-87,共9页
This paper deals with the Gevreg-hypoellipticity for a class of totally characteristic operators with the elliptic condition and the discrete boundary spectrum condition respectively.
关键词 totally characteristic operator Gevrey class wave front set tangential hypoellipticity
在线阅读 下载PDF
Improved Operation Characteristics for Nonvolatile Charge-Trapping Memory Capacitors with High-κ Dielectrics and SiGe Epitaxial Substrates
16
作者 Zhao-Zhao Hou Gui-Lei Wang +4 位作者 Jin-Juan Xiang Jia-Xin Yao Zhen-Hua Wu Qing-Zhu Zhang Hua-Xiang Yin 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第9期95-99,共5页
A novel high-κ~ A1203/HfO2/AI203 nanolaminate charge trapping memory capacitor structure based on SiGe substrates with low interface densities is successfully fabricated and investigated. The memory capacitor exhibit... A novel high-κ~ A1203/HfO2/AI203 nanolaminate charge trapping memory capacitor structure based on SiGe substrates with low interface densities is successfully fabricated and investigated. The memory capacitor exhibits excellent program-erasable characteristics. A large memory window of ~4 V, a small leakage current density of ~2 ×10-6 Acre-2 at a gate voltage of 7V, a high charge trapping density of 1.42 × 1013 cm-2 at a working vo]tage of 4-10 V and good retention characteristics are observed. Furthermore, the programming (△ VFB = 2.8 V at 10 V for 10μs) and erasing speeds (△VFB =-1.7 V at -10 V for 10μs) of the fabricated capacitor based on SiGe substrates are significantly improved as compared with counterparts reported earlier. It is concluded that the high-κ Al2O3/HfO2/Al2O3 nanolaminate charge trapping capacitor structure based on SiGe substrates is a promising candidate for future nano-scaled nonvolatile flash memory applications. 展开更多
关键词 Dielectrics and SiGe Epitaxial Substrates Improved Operation characteristics for Nonvolatile Charge-Trapping Memory Capacitors with High
原文传递
Improvement of Operation Characteristics for MONOS Charge Trapping Flash Memory with SiGe Buried Channel
17
作者 Zhao-Zhao Hou Gui-Lei Wang +2 位作者 Jia-Xin Yao Qing-Zhu Zhang Hua-Xiang Yin 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第5期110-114,共5页
We propose and investigate a novel metal/SiO_2/Si_3N_4/SiO_2/SiGe charge trapping flash memory structure(named as MONOS), utilizing Si Ge as the buried channel. The fabricated memory device demonstrates excellent pr... We propose and investigate a novel metal/SiO_2/Si_3N_4/SiO_2/SiGe charge trapping flash memory structure(named as MONOS), utilizing Si Ge as the buried channel. The fabricated memory device demonstrates excellent programerasable characteristics attributed to the fact that more carriers are generated by the smaller bandgap of Si Ge during program/erase operations. A flat-band voltage shift 2.8 V can be obtained by programming at +11 V for 100 us. Meanwhile, the memory device exhibits a large memory window of ~7.17 V under ±12 V sweeping voltage, and a negligible charge loss of 18% after 104 s' retention. In addition, the leakage current density is lower than 2.52 × 10^(-7) A·cm^(-2) below a gate breakdown voltage of 12.5 V. Investigation of leakage current-voltage indicates that the Schottky emission is the predominant conduction mechanisms for leakage current. These desirable characteristics are ascribed to the higher trap density of the Si_3N_4 charge trapping layer and the better quality of the interface between the SiO_2 tunneling layer and the Si Ge buried channel. Therefore, the application of the Si Ge buried channel is very promising to construct 3 D charge trapping NAND flash devices with improved operation characteristics. 展开更多
关键词 FB Improvement of Operation characteristics for MONOS Charge Trapping Flash Memory with SiGe Buried Channel
原文传递
Construction of a model of autologous blood intracerebral hemorrhage in rats with a double injection and double needle withdrawal and the characteristics of the operative technique
18
作者 Siyi Yin Zhenhui Jiang 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第4期355-357,共3页
BACKGROUND : Experimental animal models of intracerebral hemorrhag (ICH) are greatly needed, so the process of establishment should be ideal in hematoma formation and easy to operate. OBJECTIVE : To construct mode... BACKGROUND : Experimental animal models of intracerebral hemorrhag (ICH) are greatly needed, so the process of establishment should be ideal in hematoma formation and easy to operate. OBJECTIVE : To construct model of ICH in rats with double injection of autologous blood taken from the cut tail cut and double withdrawal of the needle (shortened as two-step injection model), and compare with those induced by single and double injections. DESIGN : A randomized controlled tria SETTING: Department of Neurology, General Hospital of Military Area Command of Chinese PLA. MATERIALS: Thirty male Wistar rats of 10 to 12 months, weighing (400±25) g, provided by the Experimental Center of Medical Animals, General Hospital of Shenyang Military Area Command of Chinese PLA, were divided randomly into 3 groups with 10 rats in each group: two-step injection group, single injection group, double injection group. METHODS : The experiment was carried out in the Department of Neurology, General Hospital of Military Area Command of Chinese PLA from March to June in 2004. Autologous blood ICH model in rats were established as follows: In the two-step injection group, 50 μL unclotted autologous blood was taken from the rat tail cut, then injected with microsyringe into the caudate nucleus, 10 μL injected at first, paused for 2 minutes, and then the rest 40 μL injected slowly and continuously within 2 minutes. After the injection, the needle was kept immovable for about 4 minutes, withdrawn 2.0 mm, again kept immovable for about 4 minute, and then removed wholly at a slow speed. In the single injection group, 50 μL unclotted tail blood was injected slowly and continuously all within 2 minutes and the needle was slowly removed;(4) In the double injection group, 10 mL blood was injected at first, paused for 2 minutes, the rest 40 μL injected evenly within 2 minutes, and then the needle was withdrawn slowly and uninterruptedly. Neurologic findings were scored in accordance with Longa's five-point scale (0-4 scores, the higher the score, the severer the neurological dysfunction). The rats were killed to remove and sections were prepared, the morphological features of hematomas were grossly observed, the maximal diameter and size of hematomas in each slice were measured with the imaging analytical system, and the volume was calculated. Meanwhile, the conveniences of the techniques were compared. MAIN OUTCOME MEASURES: The morphological features and volume of hematomas, neurologic deficit score (NDS), and the convenience of the techniques were compared. RESULTS: All the 30 rats were involved in the analysis of results without deletion. (1) Results of the morphological observation of volume of hematoma: In the two-step injection group, hematomas located in the right caudate nucleus area regularly in circular or analogously circular shape in each slice. The formation rate of hematomas in the single injection group and double injection group were lower than those in the two-step injection group [60% (6/10), 80% (8/10), 100% (10/10), P〈 0.01, 0.05]. The volume of hematomas in the single injection group and double injection group were smaller than those in the two-step injection group [(28.5±14.8), (33.4±7.4), (41.6±3.9) mm3, P〈 0.01, 0.05]. (2) NDS results: The NDS scores in the single injection group and double injection group were smaller than that in the two-step injection group (0.90±0.83, 1.30±0.78, 1.90±0.57, P〈 0.05). (3)Comparison of the convenience of the techniques: The double injection method allowed generating reproducible hematomas in rats with shortcomings that it needed autologous arterial blood from femoral artery, and precision instruments such as microinfusion pump. The two-step injection injected fresh unclotting blood taken directly from the tail cut with microsyringe into the rat brain, and it has the advantages of easy operation, no influence on the activity of thrombase, shorter duration for model establishment, and higher rate of hematoma formation, which could generate ideal and economical models of ICH. The two-step injection induced hemotoma regularly in circular or analogously circular shape in each slice, but those induced by single and double injections were mostly in strip or fusiform shapes and extending along the needle tracks or into the ventricle or subarachnoid space. CONCLUSION : The autologous blood ICH model induced by the two-step injection method is a reproducible and reliable one in regular shape, which is better than those induced by double and single injections. 展开更多
关键词 Construction of a model of autologous blood intracerebral hemorrhage in rats with a double injection and double needle withdrawal and the characteristics of the operative technique ICH
暂未订购
Analysis of the Self-Protection Characteristics of a 1.5T Bitter-Like HTS Magnet Operated at 65K
19
作者 Yan-Bing Hou Yin-Shun Wang +2 位作者 Chang-Tao Kan Xi Yuan Wei Pi 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第6期79-83,共5页
We present a conceptual configuration of a high-temperature superconducting(HTS)magnet made from REBCO(Re=Rare Earth,B=Barium,C=Copper,O=Oxide)annular plates,called a Bitter-like HTS magnet,which can operate in pe... We present a conceptual configuration of a high-temperature superconducting(HTS)magnet made from REBCO(Re=Rare Earth,B=Barium,C=Copper,O=Oxide)annular plates,called a Bitter-like HTS magnet,which can operate in persistent current mode without joint resistance and can be excited by a flux pump and without current leads and a persistent power supply.An REBCO annular magnet which can generate 1.5 T corresponding to the operating current density 80%of critical current density of the magnet at an operating temperature of65 K is conceptually designed.Then the thermal stability of the magnet is numerically simulated by Comsol software.Whein a piece of RBCO annular plate quenches,the maximum released energy is its stored energy because each REBCO annular plate in the Bitter-like magnet is in parallel.To calculate the stored energy in the REBCO annular plate,the inductance of every annular plate,including self-inductance and mutual inductance,is calculated.Compared with the minimum quench energy(MQE)and stored energy in one REBCO annular plate,the stored energy in one REBCO annular plate is always smaller than the MQE,and the REBCO annular plate will not be damaged even though the stored energy in the REBCO annular plate is fully released,which indicates that this 1.5 T Bitter-like magnet has the property of self-protection. 展开更多
关键词 REBCO Analysis of the Self-Protection characteristics of a 1.5T Bitter-Like HTS Magnet Operated at 65K HTS
原文传递
REFERENCE FUNCTIONAL AND CHARACTERISTIC SPACE FOR LAGRANGE AND BERNSTEIN OPERATORS
20
作者 S.De Marchi M.Morandi Cecchi 《Analysis in Theory and Applications》 1995年第4期6-14,共9页
This paper deals with the description and the representation of polynomials defined over n-simplices, The polynomials are computed by using two recurrent schemes: the Neville-Aitken one for the Lagrange interpolating ... This paper deals with the description and the representation of polynomials defined over n-simplices, The polynomials are computed by using two recurrent schemes: the Neville-Aitken one for the Lagrange interpolating operator and the De Casteljau one for the Bernstein-Bezier approximating operator. Both schemes fall intothe framework of transformations of the form where the F iare given numbers (forexample, at the initial step they coincide with the values of the function on a given lattice), and the coefficients (x) are linear polynomials valued in x and x is fixed. A general theory for such sequence of transformations can be found in [2] where it is also proved that these tranformations are completely characterized in term of a linear functional, reference functional. This functional is associated with a linear space., characteristic space.The concepts of reference functionals and characteristic spaces will be used and we shall prove the existence of a characteristic space for the reference functional: associated with these operators. 展开更多
关键词 REFERENCE FUNCTIONAL AND characteristic SPACE FOR LAGRANGE AND BERNSTEIN OPERATORS
在线阅读 下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部