Objective:To discuss the efficacy of Bispectral index (BIS)-monitored closed-loop targeted-controlled infusion of propofol for laparoscopic radical operation for gastric cancer.Methods:A total of 106 patients with pri...Objective:To discuss the efficacy of Bispectral index (BIS)-monitored closed-loop targeted-controlled infusion of propofol for laparoscopic radical operation for gastric cancer.Methods:A total of 106 patients with primary gastric cancer who underwent laparoscopic radical operation for gastric cancer in our hospital between August 2015 and February 2018 were chosen as the research subjects and divided into the control group (n=53) and the observation group (n=53) according to the different anesthesia methods. Control group of patients received BIS-monitored manually adjusted targeted-controlled infusion concentration of propofol, and observation group of patients received BIS-monitored closed-loop targeted-controlled infusion of propofol. The differences in hemodynamic index levels as well as serum contents of inflammatory factors and stress hormones were compared between the two groups of patients before anesthesia (T0), 30 min after surgery started (T1) and 30 min before surgery ended (T2).Results:At T0, the differences in hemodynamic index levels as well as serum contents of inflammatory factors and stress hormones were not statistically significant between the two groups. At T1 and T2, hemodynamic indexes MAP and HR levels of observation group were lower than those of control group at the corresponding time points;serum inflammatory factors sICAM-1, IL-1β, IL-8 and TNF-α contents were lower than those of control group at the corresponding time points;serum stress hormones Cor, T4 and glucagon contents were lower than those of control group at the corresponding time points.Conclusion: BIS-monitored closed-loop targeted-controlled infusion of propofol can effectively stabilize the intraoperative hemodynamics and inhibit the systemic inflammatory stress response in patients with laparoscopic radical operation for gastric cancer.展开更多
In order to solve the problem of reliability modeling and the analysis of complex systems with multiple closed-loop feedbacks,a new reliability analysis method for repairable systems with multiple closed-loop feedback...In order to solve the problem of reliability modeling and the analysis of complex systems with multiple closed-loop feedbacks,a new reliability analysis method for repairable systems with multiple closed-loop feedbacks is proposed based on the goal-oriented(GO)methodology.Firstly,the basic theories and advantages of GO method are introduced.Secondly,a type-24B multiple closed-loop feedback structure operator is proposed through GO method with its operation formula given,which expands the types of GO method operators and the application scope of their reliability analysis.Finally,taking a certain type of diesel engine fuel supply system an example,the quantitative and qualitative analysis is carried out through GO method,Monte Carlo simulation as well as FTA respectively.The availability results verify the availability of the proposed type-24B operator in the reliability analysis of multiple closed-loop feedback systems.The qualitative analysis results indicate the accuracy and usability of the GO method as a qualitative analysis method.展开更多
Goal oriented( GO) methodology is a kind of success oriented system reliability analysis method and has been used widely.The repairable system with dual input closed-loop feedback link( DICLFL) considering shutdown co...Goal oriented( GO) methodology is a kind of success oriented system reliability analysis method and has been used widely.The repairable system with dual input closed-loop feedback link( DICLFL) considering shutdown correlation didn't make reliability analysis accurately based on existing GO methodology. So, a reliability analysis method used to deal with DICLFL considering shutdown correlation is provided based on GO methodology.Firstly, a new operator, which is used to describe DICLFL considering shutdown correlation,whose number is 1,is created and named as Type 9C operator. And then,the formulas of type 9C operator are derived based on Markov process theory. Finally,the new method presented in this paper is adopted to conduct the reliability analysis of an electro-hydraulic servo speed control system. The analysis result is compared with those of Monte Carlo simulation and fault tree analysis( FTA). The comparison results show that this new reliability analysis method based on GO methodology is feasible and meaningful for reliability analysis of repairable systems with DICLFL considering shutdown correlation.Meantime,it will be useful for more other applications.展开更多
The two-player nonzero-sum linear-exponential-quadratic stochastic differential game is studied.The game takes into account the players'attitudes to risk.The nonlinear transformations and change of probability mea...The two-player nonzero-sum linear-exponential-quadratic stochastic differential game is studied.The game takes into account the players'attitudes to risk.The nonlinear transformations and change of probability measure techniques are used to study the existence of both open-loop and closed-loop Nash equilibria for the game.Some examples are constructed to illustrate their differences.Furthermore,theoretical results are applied to solve the risk-sensitive portfolio game problem in the financial market and show the effects of risk attitudes and economic performance on equilibria.展开更多
Solar energy is the raw material and main source for several applications of renewable energy systems;thus, knowledge about the intensity of solar irradiation is essential for efficiency of these systems. Electric ene...Solar energy is the raw material and main source for several applications of renewable energy systems;thus, knowledge about the intensity of solar irradiation is essential for efficiency of these systems. Electric energy sources capable of meeting the growing demands of society with minimal impacts to the environment and high efficiency have been object of research in the last decade. In this context, the conversion of sunlight into electricity through photovoltaic cells has become one of the most encouraged and used resources in the world. However, the most unpredictable factor, which hampers capturing solar irradiation, preventing a proper conversion of sunlight into electricity, is the presence of clouds in the sky. Many methods of tracking and prediction of irradiation were proposed to increase efficiency in the production of energy by photovoltaic cells. This article presents an updated review on the mechanisms used for tracking and irradiation prediction, and their respective methods. It begins with a brief review on photovoltaic systems and classification of its mechanisms. Then, it presents a detailed overview on the evolution of mechanisms and their corresponding methods for tracking and irradiation prediction. Finally, the authors conclude with an analysis of performance efficiency of the mechanisms and their corresponding methods presented, describing the pros and cons of the most significant proposals for tracking and irradiation prediction.展开更多
For dynamic stability analysis and instability mechanism understanding of multi-converter medium voltage DC power systems with droop-based double-loop control,an advanced system-level model reduction method is propose...For dynamic stability analysis and instability mechanism understanding of multi-converter medium voltage DC power systems with droop-based double-loop control,an advanced system-level model reduction method is proposed.With this method,mathematical relationships of control parameters(e.g.,current and voltage control parameters)between the system and its equivalent reduced-order model are established.First,open-loop and closed-loop equivalent reduced-order models of current control loop considering dynamic interaction among converters are established.An instability mechanism(e.g.,unreasonable current control parameters)of the system can be revealed intuitively.Theoretical guidance for adjustment of current control parameters can also be given.Then,considering dynamic interaction of current control among converters,open-loop and closed-loop equivalent reduced-order models of voltage control loop are established.Oscillation frequency and damping factor of DC bus voltage in a wide oscillation frequency range(e.g.,10–50 Hz)can be evaluated accurately.More importantly,accuracy of advanced system-level model reduction method is not compromised,even for MVDC power systems with inconsistent control parameters and different number of converters.Finally,experiments in RT-BOX hardware-in-the-loop experimental platform are conducted to validate the advanced system-level model reduction method.展开更多
文摘Objective:To discuss the efficacy of Bispectral index (BIS)-monitored closed-loop targeted-controlled infusion of propofol for laparoscopic radical operation for gastric cancer.Methods:A total of 106 patients with primary gastric cancer who underwent laparoscopic radical operation for gastric cancer in our hospital between August 2015 and February 2018 were chosen as the research subjects and divided into the control group (n=53) and the observation group (n=53) according to the different anesthesia methods. Control group of patients received BIS-monitored manually adjusted targeted-controlled infusion concentration of propofol, and observation group of patients received BIS-monitored closed-loop targeted-controlled infusion of propofol. The differences in hemodynamic index levels as well as serum contents of inflammatory factors and stress hormones were compared between the two groups of patients before anesthesia (T0), 30 min after surgery started (T1) and 30 min before surgery ended (T2).Results:At T0, the differences in hemodynamic index levels as well as serum contents of inflammatory factors and stress hormones were not statistically significant between the two groups. At T1 and T2, hemodynamic indexes MAP and HR levels of observation group were lower than those of control group at the corresponding time points;serum inflammatory factors sICAM-1, IL-1β, IL-8 and TNF-α contents were lower than those of control group at the corresponding time points;serum stress hormones Cor, T4 and glucagon contents were lower than those of control group at the corresponding time points.Conclusion: BIS-monitored closed-loop targeted-controlled infusion of propofol can effectively stabilize the intraoperative hemodynamics and inhibit the systemic inflammatory stress response in patients with laparoscopic radical operation for gastric cancer.
基金supported by the Special Support Project of SASTIND and Technologyof SASTIND(No.JSZL2019XXXB001)。
文摘In order to solve the problem of reliability modeling and the analysis of complex systems with multiple closed-loop feedbacks,a new reliability analysis method for repairable systems with multiple closed-loop feedbacks is proposed based on the goal-oriented(GO)methodology.Firstly,the basic theories and advantages of GO method are introduced.Secondly,a type-24B multiple closed-loop feedback structure operator is proposed through GO method with its operation formula given,which expands the types of GO method operators and the application scope of their reliability analysis.Finally,taking a certain type of diesel engine fuel supply system an example,the quantitative and qualitative analysis is carried out through GO method,Monte Carlo simulation as well as FTA respectively.The availability results verify the availability of the proposed type-24B operator in the reliability analysis of multiple closed-loop feedback systems.The qualitative analysis results indicate the accuracy and usability of the GO method as a qualitative analysis method.
基金Technical Basis Projects of China's MIIT(Nos.ZQ092012B003,2012090003)
文摘Goal oriented( GO) methodology is a kind of success oriented system reliability analysis method and has been used widely.The repairable system with dual input closed-loop feedback link( DICLFL) considering shutdown correlation didn't make reliability analysis accurately based on existing GO methodology. So, a reliability analysis method used to deal with DICLFL considering shutdown correlation is provided based on GO methodology.Firstly, a new operator, which is used to describe DICLFL considering shutdown correlation,whose number is 1,is created and named as Type 9C operator. And then,the formulas of type 9C operator are derived based on Markov process theory. Finally,the new method presented in this paper is adopted to conduct the reliability analysis of an electro-hydraulic servo speed control system. The analysis result is compared with those of Monte Carlo simulation and fault tree analysis( FTA). The comparison results show that this new reliability analysis method based on GO methodology is feasible and meaningful for reliability analysis of repairable systems with DICLFL considering shutdown correlation.Meantime,it will be useful for more other applications.
文摘The two-player nonzero-sum linear-exponential-quadratic stochastic differential game is studied.The game takes into account the players'attitudes to risk.The nonlinear transformations and change of probability measure techniques are used to study the existence of both open-loop and closed-loop Nash equilibria for the game.Some examples are constructed to illustrate their differences.Furthermore,theoretical results are applied to solve the risk-sensitive portfolio game problem in the financial market and show the effects of risk attitudes and economic performance on equilibria.
文摘Solar energy is the raw material and main source for several applications of renewable energy systems;thus, knowledge about the intensity of solar irradiation is essential for efficiency of these systems. Electric energy sources capable of meeting the growing demands of society with minimal impacts to the environment and high efficiency have been object of research in the last decade. In this context, the conversion of sunlight into electricity through photovoltaic cells has become one of the most encouraged and used resources in the world. However, the most unpredictable factor, which hampers capturing solar irradiation, preventing a proper conversion of sunlight into electricity, is the presence of clouds in the sky. Many methods of tracking and prediction of irradiation were proposed to increase efficiency in the production of energy by photovoltaic cells. This article presents an updated review on the mechanisms used for tracking and irradiation prediction, and their respective methods. It begins with a brief review on photovoltaic systems and classification of its mechanisms. Then, it presents a detailed overview on the evolution of mechanisms and their corresponding methods for tracking and irradiation prediction. Finally, the authors conclude with an analysis of performance efficiency of the mechanisms and their corresponding methods presented, describing the pros and cons of the most significant proposals for tracking and irradiation prediction.
基金supported by the National Key Research and Development Program of China(2020YFB1506800)the China Postdoctoral Science Foundation(2021M692378)the National Natural Science Foundation of China(51977142).
文摘For dynamic stability analysis and instability mechanism understanding of multi-converter medium voltage DC power systems with droop-based double-loop control,an advanced system-level model reduction method is proposed.With this method,mathematical relationships of control parameters(e.g.,current and voltage control parameters)between the system and its equivalent reduced-order model are established.First,open-loop and closed-loop equivalent reduced-order models of current control loop considering dynamic interaction among converters are established.An instability mechanism(e.g.,unreasonable current control parameters)of the system can be revealed intuitively.Theoretical guidance for adjustment of current control parameters can also be given.Then,considering dynamic interaction of current control among converters,open-loop and closed-loop equivalent reduced-order models of voltage control loop are established.Oscillation frequency and damping factor of DC bus voltage in a wide oscillation frequency range(e.g.,10–50 Hz)can be evaluated accurately.More importantly,accuracy of advanced system-level model reduction method is not compromised,even for MVDC power systems with inconsistent control parameters and different number of converters.Finally,experiments in RT-BOX hardware-in-the-loop experimental platform are conducted to validate the advanced system-level model reduction method.