We fitted a halo-vest on patients with a fracture of the odontoid process of the axis and evaluated the effects of conservative treatment on cervical muscular atrophy and the number and type of patient complaints afte...We fitted a halo-vest on patients with a fracture of the odontoid process of the axis and evaluated the effects of conservative treatment on cervical muscular atrophy and the number and type of patient complaints after bone union. Four patients had Anderson Type II fractures and 6 patients had Type III fractures. Bone union was observed in all patients within 3 months after injury. After halo-vest fitting, cervical muscular atrophy increased with time, however, it gradually improved after removal of the halo-vest. Patients fixed with a halo-vest for more than 10 weeks complained of cervical discomfort and limited range of motion. No patients with fixation for less than 10 weeks had problems in bone union or had cervical complaints. Thus, less than a 10-week fixation period was considered to be appropriate.展开更多
目的设计一种改良的枢椎椎板螺钉置钉方法并应用于临床,使螺钉置入更简单、更准确。方法改良枢椎椎板螺钉置钉方法的进钉点仍为棘突和椎板的交界处,但在椎板中份用磨钻磨除少许皮质开窗,用刮匙刮除松质骨,保留椎板内板,用手钻沿着...目的设计一种改良的枢椎椎板螺钉置钉方法并应用于临床,使螺钉置入更简单、更准确。方法改良枢椎椎板螺钉置钉方法的进钉点仍为棘突和椎板的交界处,但在椎板中份用磨钻磨除少许皮质开窗,用刮匙刮除松质骨,保留椎板内板,用手钻沿着枢椎椎板钻孔,在直视下通过开窗处,再继续向前钻入,探针探查钉道并攻丝后置入直径3.5~4.0mrn、长度24~30mrn螺钉。临床应用26例,其中男17例,女9例,平均年龄56.7岁。结果共置入42枚枢椎椎板螺钉,螺钉平均长度为27.1 mm(24~30 m m ),术中无需透视,术中和术后无明显技术相关的并发症发生。术后即刻或随访CT示椎板螺钉位置正确,均位于椎板间。全组病例平均随访13.4个月,未发生螺钉松动、脱出或断裂。结论改良的枢椎椎板螺钉置入技术操作简单,无需透视,并保证了螺钉处于正确位置。展开更多
文摘We fitted a halo-vest on patients with a fracture of the odontoid process of the axis and evaluated the effects of conservative treatment on cervical muscular atrophy and the number and type of patient complaints after bone union. Four patients had Anderson Type II fractures and 6 patients had Type III fractures. Bone union was observed in all patients within 3 months after injury. After halo-vest fitting, cervical muscular atrophy increased with time, however, it gradually improved after removal of the halo-vest. Patients fixed with a halo-vest for more than 10 weeks complained of cervical discomfort and limited range of motion. No patients with fixation for less than 10 weeks had problems in bone union or had cervical complaints. Thus, less than a 10-week fixation period was considered to be appropriate.
文摘目的设计一种改良的枢椎椎板螺钉置钉方法并应用于临床,使螺钉置入更简单、更准确。方法改良枢椎椎板螺钉置钉方法的进钉点仍为棘突和椎板的交界处,但在椎板中份用磨钻磨除少许皮质开窗,用刮匙刮除松质骨,保留椎板内板,用手钻沿着枢椎椎板钻孔,在直视下通过开窗处,再继续向前钻入,探针探查钉道并攻丝后置入直径3.5~4.0mrn、长度24~30mrn螺钉。临床应用26例,其中男17例,女9例,平均年龄56.7岁。结果共置入42枚枢椎椎板螺钉,螺钉平均长度为27.1 mm(24~30 m m ),术中无需透视,术中和术后无明显技术相关的并发症发生。术后即刻或随访CT示椎板螺钉位置正确,均位于椎板间。全组病例平均随访13.4个月,未发生螺钉松动、脱出或断裂。结论改良的枢椎椎板螺钉置入技术操作简单,无需透视,并保证了螺钉处于正确位置。