期刊文献+
共找到64篇文章
< 1 2 4 >
每页显示 20 50 100
Successful occluding by absorbable sutures for epicardial collateral branch perforation 被引量:2
1
作者 Li SHENG Yong-Tai GONG +1 位作者 Dang-Hui SUN Yue LI 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第10期653-656,共4页
In order to improve the success rate of chronic total occlusion (CTO)percutaneous coronary intervention (PCI), retrograde approach has been attracted more attention.Recent study reported the collateral perforation rat... In order to improve the success rate of chronic total occlusion (CTO)percutaneous coronary intervention (PCI), retrograde approach has been attracted more attention.Recent study reported the collateral perforation rate was 6.9% in retrograde CTO PCI.[1,2] Collateral related perforations were higher in patients with the epicardial collateral than that with the septal collateral.[3]Several techniques have been developed to deal with the collateral branch perforation.Here,we described the treatment of epicardial collateral branch perforation by absorbable suture segments embolization through microcatheter during retrograde CTO PCI. 展开更多
关键词 EPICARDIAL COLLATERAL branch PERFORATION occluding by ABSORBABLE SUTURES PERCUTANEOUS coronary intervention
暂未订购
左归降糖解郁方对模拟糖尿病并发抑郁症环境下海马NVU结构蛋白的作用及机制研究 被引量:3
2
作者 凌佳 柳卓 +6 位作者 刘检 朱青 韩远山 赵洪庆 孟盼 杨蕙 王宇红 《中国中医基础医学杂志》 CAS CSCD 北大核心 2021年第7期1089-1092,1147,共5页
目的:从海马神经血管单元(neurovascular unit,NVU)结构蛋白探讨左归降糖解郁方对糖尿病并发抑郁症(diabetes mellitus with depression,DD)的作用机制。方法:采用海马神经元、星形胶质细胞、脑微血管内皮细胞建立海马NVU体外共培养体系... 目的:从海马神经血管单元(neurovascular unit,NVU)结构蛋白探讨左归降糖解郁方对糖尿病并发抑郁症(diabetes mellitus with depression,DD)的作用机制。方法:采用海马神经元、星形胶质细胞、脑微血管内皮细胞建立海马NVU体外共培养体系,采用葡萄糖联合皮质酮干预模拟DD环境,将实验分为正常组、模型组、空白对照组、阳性药含药组、左归降糖解郁方含药组,造模干预18 d后,细胞电阻仪检测跨内皮细胞电阻值,千分尺检测4 h渗漏试验的液面高度值,Western blot法检测胶质纤维酸性蛋白(glial fibrillary acidic protein,GFAP)、间隙连接蛋白(Connexin43,Cx43)与脑微血管内皮细胞(The brain microvascular endothelial cells,BMECs)结构蛋白occluding的表达变化。结果:与正常对照组比较,模型组跨内皮细胞电阻值显著降低(P<0.05),4 h渗漏试验液面差显著增加(P<0.01),NVU结构蛋白GFAP、CX43、occluding表达均显著下调(P<0.01,P<0.05);与模型组比较,中药复方左归降糖解郁方与阳性药二甲双胍+氟西汀均能明显逆转上述现象(P<0.01,P<0.05)。结论:左归降糖解郁方对模拟DD环境下海马NVU损伤具有一定修复作用,其作用机制可能与调控海马NVU结构蛋白GFAP、CX43及occluding的表达有关。 展开更多
关键词 左归降糖解郁方 糖尿病并发抑郁症 海马 神经血管单元 GFAP CX43 occluding
暂未订购
A Comprehensive Review of Face Detection Techniques for Occluded Faces:Methods,Datasets,and Open Challenges
3
作者 Thaer Thaher Majdi Mafarja +2 位作者 Muhammed Saffarini Abdul Hakim H.M.Mohamed Ayman A.El-Saleh 《Computer Modeling in Engineering & Sciences》 2025年第6期2615-2673,共59页
Detecting faces under occlusion remains a significant challenge in computer vision due to variations caused by masks,sunglasses,and other obstructions.Addressing this issue is crucial for applications such as surveill... Detecting faces under occlusion remains a significant challenge in computer vision due to variations caused by masks,sunglasses,and other obstructions.Addressing this issue is crucial for applications such as surveillance,biometric authentication,and human-computer interaction.This paper provides a comprehensive review of face detection techniques developed to handle occluded faces.Studies are categorized into four main approaches:feature-based,machine learning-based,deep learning-based,and hybrid methods.We analyzed state-of-the-art studies within each category,examining their methodologies,strengths,and limitations based on widely used benchmark datasets,highlighting their adaptability to partial and severe occlusions.The review also identifies key challenges,including dataset diversity,model generalization,and computational efficiency.Our findings reveal that deep learning methods dominate recent studies,benefiting from their ability to extract hierarchical features and handle complex occlusion patterns.More recently,researchers have increasingly explored Transformer-based architectures,such as Vision Transformer(ViT)and Swin Transformer,to further improve detection robustness under challenging occlusion scenarios.In addition,hybrid approaches,which aim to combine traditional andmodern techniques,are emerging as a promising direction for improving robustness.This review provides valuable insights for researchers aiming to develop more robust face detection systems and for practitioners seeking to deploy reliable solutions in real-world,occlusionprone environments.Further improvements and the proposal of broader datasets are required to developmore scalable,robust,and efficient models that can handle complex occlusions in real-world scenarios. 展开更多
关键词 Occluded face detection feature-based deep learning machine learning hybrid approaches datasets
在线阅读 下载PDF
A Hybrid Approach for Heavily Occluded Face Detection Using Histogram of Oriented Gradients and Deep Learning Models
4
作者 Thaer Thaher Muhammed Saffarini +3 位作者 Majdi Mafarja Abdulaziz Alashbi Abdul Hakim Mohamed Ayman A.El-Saleh 《Computer Modeling in Engineering & Sciences》 2025年第8期2359-2394,共36页
Face detection is a critical component inmodern security,surveillance,and human-computer interaction systems,with widespread applications in smartphones,biometric access control,and public monitoring.However,detecting... Face detection is a critical component inmodern security,surveillance,and human-computer interaction systems,with widespread applications in smartphones,biometric access control,and public monitoring.However,detecting faces with high levels of occlusion,such as those covered by masks,veils,or scarves,remains a significant challenge,as traditional models often fail to generalize under such conditions.This paper presents a hybrid approach that combines traditional handcrafted feature extraction technique called Histogram of Oriented Gradients(HOG)and Canny edge detection with modern deep learning models.The goal is to improve face detection accuracy under occlusions.The proposed method leverages the structural strengths of HOG and edge-based object proposals while exploiting the feature extraction capabilities of Convolutional Neural Networks(CNNs).The effectiveness of the proposed model is assessed using a custom dataset containing 10,000 heavily occluded face images and a subset of the Common Objects in Context(COCO)dataset for non-face samples.The COCO dataset was selected for its variety and realism in background contexts.Experimental evaluations demonstrate significant performance improvements compared to baseline CNN models.Results indicate that DenseNet121 combined with HOG outperforms other counterparts in classification metrics with an F1-score of 87.96%and precision of 88.02%.Enhanced performance is achieved through reduced false positives and improved localization accuracy with the integration of object proposals based on Canny and contour detection.While the proposed method increases inference time from 33.52 to 97.80 ms,it achieves a notable improvement in precision from 80.85% to 88.02% when comparing the baseline DenseNet121 model to its hybrid counterpart.Limitations of the method include higher computational cost and the need for careful tuning of parameters across the edge detection,handcrafted features,and CNN components.These findings highlight the potential of combining handcrafted and learned features for occluded face detection tasks. 展开更多
关键词 Occluded face detection HOG canny edge detection deep learning features extraction
在线阅读 下载PDF
2025 Chinese Expert Consensus on Clinical Applications of Biodegradable Patent Foramen Ovale Occluders
5
作者 Caojin Zhang Haibo Hu +11 位作者 Gangcheng Zhang Qiguang Wang Xiaobin Chen Yingzhang Cheng Qunshan Shen Jie Yuan Wenqi Zhang Yuanshi Li Xuan Zheng Xiangbin Pan Professional Committee of National Quality Management and Control Center for Structural Heart Diseases Professional Committee of Structural Heart Diseases of the National Cardiovascular Disease Expert Committee 《Congenital Heart Disease》 2025年第4期403-420,共18页
Compared with traditional nickel-titanium alloy patent foramen ovale occluders,which are widely used in clinical practice,biodegradable patent foramen ovale occluders have obvious differences in material characteristi... Compared with traditional nickel-titanium alloy patent foramen ovale occluders,which are widely used in clinical practice,biodegradable patent foramen ovale occluders have obvious differences in material characteristics,interventional operation mode and postoperative management strategy.This article gives expert consensus on the selection of clinical indications and standardized operating procedures,so as to standardize the clinical application of biodegradable patent foramen ovale occluders. 展开更多
关键词 Patent foramen ovale BIODEGRADABLE OCCLUDER
暂未订购
Device-edge collaborative occluded face recognition method based on cross-domain feature fusion
6
作者 Puning Zhang Lei Tan +3 位作者 Zhigang Yang Fengyi Huang Lijun Sun Haiying Peng 《Digital Communications and Networks》 2025年第2期482-492,共11页
The lack of facial features caused by wearing masks degrades the performance of facial recognition systems.Traditional occluded face recognition methods cannot integrate the computational resources of the edge layer a... The lack of facial features caused by wearing masks degrades the performance of facial recognition systems.Traditional occluded face recognition methods cannot integrate the computational resources of the edge layer and the device layer.Besides,previous research fails to consider the facial characteristics including occluded and unoccluded parts.To solve the above problems,we put forward a device-edge collaborative occluded face recognition method based on cross-domain feature fusion.Specifically,the device-edge collaborative face recognition architecture gets the utmost out of maximizes device and edge resources for real-time occluded face recognition.Then,a cross-domain facial feature fusion method is presented which combines both the explicit domain and the implicit domain facial.Furthermore,a delay-optimized edge recognition task scheduling method is developed that comprehensively considers the task load,computational power,bandwidth,and delay tolerance constraints of the edge.This method can dynamically schedule face recognition tasks and minimize recognition delay while ensuring recognition accuracy.The experimental results show that the proposed method achieves an average gain of about 21%in recognition latency,while the accuracy of the face recognition task is basically the same compared to the baseline method. 展开更多
关键词 Occluded face recognition Cross-domain feature fusion Device-edge collaboration
在线阅读 下载PDF
Welding of shape memory alloy to stainless steel for medical occluder 被引量:3
7
作者 吕世雄 杨仲林 董红刚 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2013年第1期156-160,共5页
Dissimilar metal joining between NiTi shape memory alloy(SMA) and stainless steel was conducted.A cluster of NiTi SMA wires were first joined with tungsten inert gas(TIG) welding process,then the NiTi SMA TIG weld... Dissimilar metal joining between NiTi shape memory alloy(SMA) and stainless steel was conducted.A cluster of NiTi SMA wires were first joined with tungsten inert gas(TIG) welding process,then the NiTi SMA TIG weld was welded to a stainless steel pipe with laser spot welding process.The microstructure of the welds was examined with an optical microscope and the elemental distribution in the welds was measured by electron probe microanalysis(EPMA).The results show that TiC compounds dispersively distribute in the NiTi SMA TIG weld.However,the amount of TiC compounds greatly decreases around the fusion boundary of the laser spot weld between the NiTi SMA and stainless steel.Mutual diffusion between NiTi shape memory alloy and stainless steel happen within a short distance near the fusion boundary,and intermetallic compounds such as Ni3Ti+(Fe,Ni)Ti appear around the fusion boundary. 展开更多
关键词 medical occluder NiTi alloy shape memory alloy stainless steel laser spot welding dissimilar metal joining Ni3Ti (Fe Ni)Ti
在线阅读 下载PDF
Zonula occludin toxin,a microtubule binding protein 被引量:1
8
作者 MariaRosaria DiPierro Alessio Fasano 《World Journal of Gastroenterology》 SCIE CAS CSCD 2000年第3期330-334,共5页
AIM To investigate the interaction of Zot withmicrotubule.METHODS Zot affinity column was applied topurify Zot-binding protein(s)from crudeintestinal cell lysates.After incubation at roomtemperature,the column was w... AIM To investigate the interaction of Zot withmicrotubule.METHODS Zot affinity column was applied topurify Zot-binding protein(s)from crudeintestinal cell lysates.After incubation at roomtemperature,the column was washed and theproteins bound to the Zot affinity column wereeluted by step gradient with NaCl(0.3 mol·L<sup>-1</sup>-0.5mol·L<sup>-1</sup>).The fractions were subjected to6.0%-15.0%(w/v)gradient SDS-PAGE andthen transferred to PVDF membrane for N-terminal sequencing.Purified Zot and tauprotein were blotted by using anti-Zot or anti-tauantibodies.Finally,purified Zot was tested in anin vitro tubulin binding assay.RESULTS Fractions from Zot affinity columnyielded two protein bands with a Mr of 60 kU and45kU respectively.The N-terminal sequence ofthe 60 kU band resulted identical to β-tubulin.Zot also cross-reacts with anti-tau antibodies.Inthe in vitro tubulin binding assay,Zot co-precipitate with Mt,further suggesting that Zotpossesses tubulin-binding properties.CONCLUSION Taken together,these resultssuggest that Zot regulates the permeability ofintestinal tight junctions by binding tointracellular Mt,with the subsequent activationof the intracellular signaling leading to thepermeabilization of intercellular tight junctions. 展开更多
关键词 microtubules MICROTUBULE PROTEINS microtubule-associated PROTEINS INTERCELLULAR junctions vibrio CHOLERAE CHOLERA TOXIN zonula occluding TOXIN
暂未订购
Indirect Tensile Characterization of Graphite Platelet Reinforced Vinyl Ester Nanocomposites at High-Strain Rate 被引量:1
9
作者 Brahmananda Pramanik P. Raju Mantena +1 位作者 Tezeswi Tadepalli Arunachalam M. Rajendran 《Open Journal of Composite Materials》 2014年第4期201-214,共14页
An indirect tensile testing method is proposed for characterizing low strength graphite platelet reinforced vinyl ester nanocomposites at high-strain rate. In this technique, the traditional Brazilian disk (diametrica... An indirect tensile testing method is proposed for characterizing low strength graphite platelet reinforced vinyl ester nanocomposites at high-strain rate. In this technique, the traditional Brazilian disk (diametrical compression) test method for brittle materials is utilized along with conventional split-Hopkinson pressure bars (SHPB) for evaluating cylindrical disk specimens. The cylindrical disk specimen is held snugly in between two concave end fixtures attached to the incident and transmission bars. To eliminate the complexities of conventional strain gage application, a non-contact Laser Occluding Expansion Gage (LOEG) has been adapted for measuring the diametrical transverse expansion of the specimen under high-strain rate diametrical compressive loading. Failure diagnosis using high-speed digital photography validates the viability of utilizing this indirect test method for characterizing the tensile properties of xGnP (exfoliated graphite nanoplatelets) reinforced and additional CTBN (Carboxyl Terminated Butadiene Nitrile) toughened vinyl ester based nanocomposites. Also, quasi-static indirect tensile response agrees with previous investigations conducted using the traditional dog-bone specimen in direct tensile tests. Investigation of both quasi-static and dynamic indirect tensile test responses shows the strain rate effect on the tensile strength and energy absorbing capacity of the candidate materials. The contribution of reinforcement to the tensile properties of the candidate materials is presented. 展开更多
关键词 Split Hopkinson Pressure BARS High-Strain Rate Tensile TEST BRAZILIAN Disk TEST Method Laser occluding Expansion Gage NANOCOMPOSITES
暂未订购
Computer Aided Modeling and Dynamic Analysis of A New Surgical Instrument
10
作者 Jeremy (Zheng) Li 《Surgical Science》 2012年第5期242-244,共3页
One major difference among surgical instruments is the level of bodily disruption and tissue trauma that surgical devices might cause the patients. This newly designed and developed surgical instrument aims at minimal... One major difference among surgical instruments is the level of bodily disruption and tissue trauma that surgical devices might cause the patients. This newly designed and developed surgical instrument aims at minimally invasive therapy procedure, more reliable and durable function, less operational force, and reduced manufacturing cost. The computer aided modeling and simulation have been applied to help this new instrument design and analysis. This improved new surgical instrument is designed to use in general surgery to prevent patient's vessels and tissues from being damaging due to reliable motion control of surgical clips with no unexpected clip drop. It can also be applied to surgical education purpose to educate medical students for their future surgical careers. The prototype testing indicated that the handle operational force to close surgical clips is lower than current surgical clip instruments, product manufacturing is cost-effective due to less dimensional tolerance control of this new instrument design, more reliable instrument function, and good mechanical advantage. 展开更多
关键词 SURGICAL Instrument MECHANICAL ADVANTAGE SUTURE occluding
暂未订购
The Enrichment of Chloride Anion in the Occluded Cell and Its Effect on Stress Corrosion Crack of 304 Stainless Steel in Low Chloride Concentration Solution 被引量:12
11
作者 吕国诚 许淳淳 +2 位作者 吕忆民 程海东 何宗虎 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第4期646-649,共4页
The enrichment of chloride anion within the occluded cell (OC) for Type 304 austenitic stainless steel in low chloride concentration solution has been investigated by means of a simulated OC. The influence of the en... The enrichment of chloride anion within the occluded cell (OC) for Type 304 austenitic stainless steel in low chloride concentration solution has been investigated by means of a simulated OC. The influence of the enrichment of chloride anion on stress corrosion crack (SCC) of Type 304 stainless steel has been studied. It was observed that the amount of chloride anion migration was proportional to the charge flowing through the anode. Owning to the effects of enrichment of chloride anion, low chloride concentration solution could induce SCC for Type 304 stainless steel. 展开更多
关键词 304 austenitic stainless steel occluded cells enrichment of chloride anion stress corrosion crack
在线阅读 下载PDF
Management of an occluded biliary metallic stent 被引量:6
12
作者 Wiriyaporn Ridtitid Rungsun Rerknimitr 《World Journal of Gastrointestinal Endoscopy》 CAS 2012年第5期157-161,共5页
In patients with a malignant biliary obstruction who require biliary drainage,a self-expandable metallic stent(SEMS) provides longer patency duration than a plastic stent(PS).Nevertheless,a stent occlusion by tumor in... In patients with a malignant biliary obstruction who require biliary drainage,a self-expandable metallic stent(SEMS) provides longer patency duration than a plastic stent(PS).Nevertheless,a stent occlusion by tumor ingrowth,tumor overgrowth and biliary sludge may develop.There are several methods to manage occluded SEMS.Endoscopic management is the preferred treatment,whereas percutaneous intervention is an alternative approach.Endoscopic treatment involves mechanical cleaning with a balloon and a second stent insertion as stent-in-stent with either PS or SEMS.Technical feasibility,patient survival and cost-effectiveness are important factors that determine the method of re-drainage and stent selection. 展开更多
关键词 Occluded BILIARY METALLIC STENT Re-drainage COST EFFECTIVENESS
暂未订购
Left atrial appendage occlusion: A better alternative to anticoagulation? 被引量:3
13
作者 Ibrahim Akin Christoph A Nienaber 《World Journal of Cardiology》 CAS 2017年第2期139-146,共8页
Non-valvular atrial fibrillation is associated with a significantly increased risk of embolic stroke due to blood clot forming predominantly in the left atrial appendage(LAA). Preventive measures to avoid embolic even... Non-valvular atrial fibrillation is associated with a significantly increased risk of embolic stroke due to blood clot forming predominantly in the left atrial appendage(LAA). Preventive measures to avoid embolic events are permanent administration of anticoagulants or surgical closure of the LAA. Various clinical trials provide evidence about safety, effectiveness and therapeutic success of LAA occlusion using various cardiac occluder devices. The use of such implants for interventional closure of the LAA is likely to become a valuable alternative for stroke prevention, especially in patients with contraindication for oral anticoagulation as safety, clinical benefit and cost-effectiveness of LAA occlusion has recently been demonstrated. 展开更多
关键词 Left atrial appendage THROMBUS Occlude STROKE
暂未订购
Cardiac resynchronization therapy for heart failure induced by left bundle branch block after transcatheter closure of ventricular septal defect 被引量:3
14
作者 Rong-Zeng DU Jun QIAN Jun WU Yi LIANG Guang-Hua CHEN Tao SUN Ye ZHOU Yang ZHAO Jin-Chuan YAN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2014年第4期357-362,共6页
A 54-year-old female patient with congenital heart disease had a persistent complete left bundle branch block three months after closure by an Amplatzer ventricular septal defect occluder. Nine months later, the patie... A 54-year-old female patient with congenital heart disease had a persistent complete left bundle branch block three months after closure by an Amplatzer ventricular septal defect occluder. Nine months later, the patient suffered from chest distress, palpitation, and sweating at daily activities, and her 6-min walk distance decreased significantly (155 m). Her echocardiography showed increased left ventricular end-diastolic diameter with left ventricular ejection fraction of 37%. Her symptoms reduced significantly one week after received cardiac resynchronization therapy. She had no symptoms at daily activities, and her echo showed left ventricular ejection fraction of 46%and 53%. Moreover, left ventricular end-diastolic diameter decreased 6 and 10 months after cardiac resynchronization therapy, and 6-min walk dis-tance remarkably increased. This case demonstrated that persistent complete left bundle branch block for nine months after transcatheter closure with ventricular septal defect Amplatzer occluder could lead to left ventricular enlargement and a significant decrease in left ventricular systolic function. Cardiac resynchronization therapy decreased left ventricular end-diastolic diameter and increased left ventricular ejection fraction, thereby improving the patient’s heart functions. 展开更多
关键词 Ventricular septal defect Amplatzer occluder Left bundle branch block Heart failure Cardiac resynchronization therapy
在线阅读 下载PDF
Smart Objects Identification System for Robotic Surveillance 被引量:3
15
作者 Amir Akramin Shafie Azhar Bin Mohd Ibrahim Muhammad Mahbubur Rashid 《International Journal of Automation and computing》 EI CSCD 2014年第1期59-71,共13页
Video surveillance is an active research topic in computer vision.In this paper,humans and cars identifcation technique suitable for real time video surveillance systems is presented.The technique we proposed includes... Video surveillance is an active research topic in computer vision.In this paper,humans and cars identifcation technique suitable for real time video surveillance systems is presented.The technique we proposed includes background subtraction,foreground segmentation,shadow removal,feature extraction and classifcation.The feature extraction of the extracted foreground objects is done via a new set of afne moment invariants based on statistics method and these were used to identify human or car.When the partial occlusion occurs,although features of full body cannot be extracted,our proposed technique extracts the features of head shoulder.Our proposed technique can identify human by extracting the human head-shoulder up to 60%–70%occlusion.Thus,it has a better classifcation to solve the issue of the loss of property arising from human occluded easily in practical applications.The whole system works at approximately 16 29 fps and thus it is suitable for real-time applications.The accuracy for our proposed technique in identifying human is very good,which is 98.33%,while for cars identifcation,the accuracy is also good,which is 94.41%.The overall accuracy for our proposed technique in identifying human and car is at 98.04%.The experiment results show that this method is efective and has strong robustness. 展开更多
关键词 Humans and cars identifcation partially occluded human afne moment invariants video surveillance systems machine vision
原文传递
Investigation on corrosion behaviour of asextruded near eutectic Al-Si-Mg alloy by neutral salt spray test 被引量:3
16
作者 Wu Yuna Liao Hengcheng Yang Jian 《China Foundry》 SCIE CAS 2013年第4期207-212,共6页
In order to provide scientific basis for advanced applications of near eutectic Al-Si-Mg alloys as architectural profiles, a comparative study on the corrosion resistance of an as-extruded near eutectic AI-Si-Mg alloy... In order to provide scientific basis for advanced applications of near eutectic Al-Si-Mg alloys as architectural profiles, a comparative study on the corrosion resistance of an as-extruded near eutectic AI-Si-Mg alloy and AA6063 aluminium alloy was carried out by means of neutral salt spray test. The corroded surfaces of the alloys were examined with optical microscopy and scanning electron microscope (SEM). Results show that the corrosion type of these two alloys is pitting corrosion. The number of corrosion pits in the AA6063 aluminium alloy is more than that in the near eutectic AI-Si-Mg alloy, but the pits in the latter alloy are much larger and deeper. Because the relatively low polarization resistance of the near eutectic alloy leads to poorer repassivation ability, autocatalytic acidification occurs once a pit forms. Thus, occluded corrosion cells are developed in this alloy. 展开更多
关键词 near eutectic AI-Si alloy AA6063 alloy pitting corrosion occluded corrosion cells
在线阅读 下载PDF
Safety of an improved patent ductus arteriosus occluder for transcatheter closure of perimembranous ventricular septal defects with abnormally attached tricuspid chordae tendineae 被引量:2
17
作者 Lu He Ya-Juan Du +1 位作者 Ge-Sheng Cheng Yu-Shun Zhang 《World Journal of Clinical Cases》 SCIE 2019年第5期562-571,共10页
BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid r... BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid regurgitation(TR),associated with conventional ventricular septal defect devices. However, whether certain defects such as PmVSD with abnormally attached tricuspid are fit for interventional treatment is still disputable.AIM To explore the feasibility and safety of transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae using an improved patent ductus arteriosus(PDA) occluder.METHODS We retrospectively analyzed 20 patients diagnosed with PmVSD with abnormally attached tricuspid chordae tendineae who underwent interventional treatment using an improved PDA occluder at our center from January 2012 to January 2016. Baseline characteristics and procedural and follow-up data were analyzed.RESULTS All 20 patients achieved procedure success. No heart block occurred during the operation. One patient had a transient complete right bundle branch block within48 h post-procedure and reverted to normal rhythm after intravenous injections of dexamethasone for 3 d. For all 20 patients, no residual shunt was observed by transthoracic echocardiography post-procedure. During the average follow-up period of 2.4 years, no severe TR was observed.CONCLUSION Using of the improved PDA occluder for the transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae is a safe and promising treatment option. However, long-term follow-up in a large group of patients is still warranted. 展开更多
关键词 Ventricular SEPTAL defect TRANSCATHETER PATENT ductus arteriosus occlude TRICUSPID REGURGITATION Chordae tendineae
暂未订购
An improved method for multiple targets tracking 被引量:2
18
作者 朱青 刘宏立 +4 位作者 陈炳权 李劲菊 万琴 孙猛 袁小芳 《Journal of Central South University》 SCIE EI CAS 2012年第10期2852-2859,共8页
The difficulty of multiple targets tracking is how to quickly fulfill the target matching from one flame image to another and fix the position of the target. In order to accurately choose target feature information fo... The difficulty of multiple targets tracking is how to quickly fulfill the target matching from one flame image to another and fix the position of the target. In order to accurately choose target feature information for reliable matching, simplify operations under the reliable precondition, and realize precise moving objects tracking, an approach based on Kalman prediction and feature matching was proposed. The position of the target in next frame image was predicted by Kalman, and then the moving objects of two adjacent frames were matched by the centroid and area methods. When occlusion occurs, the best matching result was found to realize tracking by matching matrix algorithm. The simulation results show that the proposed method can achieve multiple targets tracking accurately and in real-time under complicated motion movements. 展开更多
关键词 Kalman prediction feature matching centroid and area matching equations image occluded processing matchingmatrix algorithm
在线阅读 下载PDF
Effective stress in soils under different saturation conditions 被引量:1
19
作者 徐浩峰 谢康和 《Journal of Central South University》 SCIE EI CAS 2011年第6期2137-2142,共6页
BISHOP’s effective stress or two state stress variables are unsatisfactory for unsaturated soils where one of fluid phases is discontinuous, so new expressions of effective stress should be founded. The approach for ... BISHOP’s effective stress or two state stress variables are unsatisfactory for unsaturated soils where one of fluid phases is discontinuous, so new expressions of effective stress should be founded. The approach for derivation was according to the principle of equilibrium of forces (i.e., the stress-sharing principle), and it was firstly validated by demonstrating TERZAGHI’s principle of effective stress. And then, the derivations were subdivided into four parts according to different pore air states: 1) air bubbles were spherical and suspended in pore water; 2) air bubbles were bound on soil skeleton; 3) air bubbles held almost the single section of pore; 4) air phase was continuous. The different formulae of effective stress were presented. Conclusions are drawn as follows: 1) For nearly-saturated soils, the "real" effective stress would be a little smaller than TERZAGHI’s effective stress; 2) For soils in which air phase is discontinuous in the form of bubbles, a new concept of pore air elastic pressure is put forward, and the total stress can be constituted by effective stress, pore water pressure and pore air elastic pressure; 3) For soils in which air phase is continuous, effective stress is equal to the value of the total stress plus suction; 4) Suction can be divided into two parts: one is the effect caused by additional pressure, and the other is the contract action by the "skin". 展开更多
关键词 unsaturated soils effective stress SUCTION surface tension occluded gas SATURATION
在线阅读 下载PDF
Pulmonary endarterectomy in chronic thromboembolic pulmonary hypertension: How can patients be better selected? 被引量:1
20
作者 Juan C Grignola Enric Domingo 《World Journal of Cardiology》 CAS 2013年第3期18-21,共4页
Chronic thromboembolic pulmonary hypertension (CTEPH) comprises organizing thrombotic obstructions in the pulmonary arteries by nonresolving thromboemboli, formation of fibrosis and remodeling of pulmonary blood vesse... Chronic thromboembolic pulmonary hypertension (CTEPH) comprises organizing thrombotic obstructions in the pulmonary arteries by nonresolving thromboemboli, formation of fibrosis and remodeling of pulmonary blood vessels. Surgical pulmonary endarterectomy (PEA) is the therapy of choice for patients with surgically accessible CTEPH, which leads to a profound improvement in hemodynamics, functional class and survival. Select- ing the candidates that will benefit from surgery is still a challenging task. Criteria for surgical suitability have been described but the decision-making for or against surgical intervention remains still subjective. The optimal characterization of the reciprocal contribution of large vessel and small vessel disease in the elevation of pulmonary vascular resistance is crucial for the indication and outcome of PEA. Recently, Toshner et al intended to validate the partition resistance into small and large vessels compartments (upstream resistance:Rup) by the occlusion technique in the preoperative assessment of PEA. We discuss the advantages and disadvantages of Rup and compare it with other hemodynamic predictor to evaluate operative risk in CTEPH patients. 展开更多
关键词 PULMONARY ENDARTERECTOMY OPERABILITY Chronic THROMBOEMBOLIC PULMONARY hypertension PULMONARY ARTERY occluded pressure PULMONARY VASCULAR resistance
暂未订购
上一页 1 2 4 下一页 到第
使用帮助 返回顶部