期刊文献+
共找到134篇文章
< 1 2 7 >
每页显示 20 50 100
First Observations of Cosmic Ray Neutrons by a Mini Neutron Monitor at Riyadh, Saudi Arabia 被引量:1
1
作者 Maghrabi Abdullrahman Aldosari Abdulah Altilasi Mohammed 《International Journal of Astronomy and Astrophysics》 2020年第4期319-333,共15页
In April 2017, a mini neutron monitor (NM) was installed at King Abdulaziz City for Science and Technology (KACST) central Saudi Arabia (Riyadh;cut-off rigidity, Rc = 14.4 Gv) for continuous observation of the cosmic ... In April 2017, a mini neutron monitor (NM) was installed at King Abdulaziz City for Science and Technology (KACST) central Saudi Arabia (Riyadh;cut-off rigidity, Rc = 14.4 Gv) for continuous observation of the cosmic ray (CR) neutrons. The detector was built as a major aspect of the international scientific joint effort between the Centre of Space Research (North-West University, Potchefstroom, South Africa) and KACST. The recorded data correspond to low energy neutrons that primarily have energies lower than 20 GeV. In this paper, a brief description about the mini NM detector will be given. The influence of atmospheric pressure on the recorded CR neutrons was studied and the barometric coefficient was calculated and used to eliminate the pressure effects from the measured data. The obtained coefficient was consistent with those previously obtained by several investigators. The daily variation of the CR neutron was studied and characterized. Short-term CR periodicities, such as the 27-day period, and its two harmonics, were identified. The obtained periodicities are in agreement with those reported by different researchers. The obtained results from this detector have been compared to the existing 1 m<sup>2</sup> scintillator detector showing comparable results. Long-term data from this detector will be of incredible significance to the research community to investigate several types of CR variations resulting from solar activity at such high cut off rigidity site. 展开更多
关键词 Mini neutron monitor Cosmic Ray Saudi Arabia PERIODICITIES
在线阅读 下载PDF
Development of a spherical tissue equivalent proportional counter for neutron monitoring
2
作者 姜志刚 袁永刚 +1 位作者 王和义 陈华 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第6期90-94,共5页
A spherical tissue equivalent proportional counter(TEPC) for neutron monitoring has been developed. It was properly designed to produce a uniform electric field intensity around the anode wire. An internal ^(241)Am al... A spherical tissue equivalent proportional counter(TEPC) for neutron monitoring has been developed. It was properly designed to produce a uniform electric field intensity around the anode wire. An internal ^(241)Am alpha source was adopted for lineal energy calibration. The TEPC was characterized in terms of dose equivalent response in a standard ^(252)Cf neutron field, and was tested with 2.45 MeV neutrons. Microdosimetric spectra, frequency mean lineal energy and dose-average mean lineal energy of 2.45 MeV neutrons were obtained and compared with FLUKA Monte Carlo simulation results. The measurement and simulation results agreed well. The mean quality factor and dose equivalent values evaluated from the 2.45 MeV neutron measurement were in good agreement with the recommended effective quality factor and ambient dose equivalent H*(10),respectively. Preliminary results have proved the availability of the developed TEPC for neutron monitoring. 展开更多
关键词 组织等效正比计数器 中子场 正比计数管 监测 种球 剂量响应 蒙特卡罗模拟 剂量当量
在线阅读 下载PDF
High-precision and wide-range real-time neutron flux monitor system through multipoint linear calibration 被引量:6
3
作者 Ren-Jie Zhu Xiang Zhou +9 位作者 Zi-Hao Liu Wen-Di Wang Xiao-Li Mou Teng-Fei Fang Qing-Li Ma Xiu-Feng Xu Guo-Liang Yuan Li Zhao Ling-Feng Wei Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第9期98-106,共9页
The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test rea... The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results. 展开更多
关键词 Multipoint linear calibration Real time Simulated neutron signal neutron flux monitoring ITER HL-2A
在线阅读 下载PDF
Development of a wide-range and fast-response digitizing pulse signal acquisition and processing system for neutron flux monitoring on EAST 被引量:3
4
作者 Li Yang Hong-Rui Cao +7 位作者 Jin-Long Zhao Zi-Han Zhang Qiang Li Guo-Bin Wu Yong-Qiang Zhang Guo-Qiang Zhong Li-Qun Hu Zi-Jun Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第3期126-136,共11页
The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The measurement result... The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The measurement result of neutron flux monitoring(NFM)is a significant feedback parameter related to the acquisition of radiation protection-related information and rapid fluctuations in neutron emission induced by plasma magnetohydrodynamic activity.Therefore,a wide range and high time resolution are required for the NFM system on EAST.To satisfy these requirements,a digital pulse signal acquisition and processing system with a wide dynamic range and fast response time was developed.The present study was conducted using a field-programmable gate array(FPGA)and peripheral component interconnect extension for instrument express(PXIe)platform.The digital dual measurement modes,which are composed of the pulse-counting mode and AC coupled square integral's Campbelling mode,were designed to expand the measurement range of the signal acquisition and processing system.The time resolution of the signal acquisition and processing system was improved from 10 to 1 ms owing to utilizing highspeed analog-to-digital converters(ADCs),a high-speed PXIe communication with a direct memory access(DMA)mode,and online data preprocessing technology of FPGA.The signal acquisition and processing system was tested experimentally in the EAST radiation field.The test results showed that the time resolution of NFM was improved to 1 ms,and the dynamic range of the neutron counts rate was expanded to more than 10^(6) counts per second.The Campbelling mode was calibrated using a multipoint average linear fitting method;subsequently,the fitting coefficient reached 0.9911.Therefore,the newly developed pulse signal acquisition and processing system ensures that the NFM system meets the requirements of high-parameter experiments conducted on EAST more effectively. 展开更多
关键词 EAST neutron flux monitoring High time resolution Wide range Pulse signal acquisition and processing system
在线阅读 下载PDF
Fusion Neutron Flux Monitor for ITER 被引量:2
5
作者 杨进蔚 杨青巍 +3 位作者 肖功珊 张炜 宋先瑛 李旭 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第2期141-147,共7页
Neutron flux monitor (NFM) as an important diagnostic sub-system in ITER (international thermonuclear experimental reactor) provides a global neutron source intensity, fusion power and neutron flux in real time. T... Neutron flux monitor (NFM) as an important diagnostic sub-system in ITER (international thermonuclear experimental reactor) provides a global neutron source intensity, fusion power and neutron flux in real time. Three types of neutron flux monitor assemblies with different sensitivities and shielding materials have been designed. Through MCNP (Mante-Carlo neutral particle transport code) calculations, this extended system of NFM can detect the neutron flux in a range of 10^4 n/(cm^2.s) to 10^14 n/(cm^2.s). It is capable of providing accurate neutron yield measurements for all operational modes encountered in the ITER experiments including the in-situ calibration. Combining both the counting mode and Campbelling (MSV; Mean Square Voltage) mode in the signal processing units, the requirement of the dynamic range (107) for these NFMs and time resolution (1 ms) can be met. Based on a uncertainty analysis, the estimated absolute measurement accuracies of the total fusion neutron yield can reach the required 10% level in both the early stage of the DD-phase and the DD-phase, the absolute measurement accuracy full power DT operation mode. In the advanced would be better than 20%. 展开更多
关键词 neutron flux monitor international thermonuclear experimental reactor(ITER) assembly of fission chamber
在线阅读 下载PDF
Development of Prototype Neutron Flux Monitor for ITER 被引量:2
6
作者 Yang Jinwei Song Xianying +6 位作者 Zhang Wei Li Xu Lee Wenzhong Wang Shiqing Xiao Gongshan Yang Bo Lu Shuangtong 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第3期2860-2862,共3页
The prototype neutron flux monitor consists of a high purity ^(235)U fission chamber detector and a'blank'detector,which is a fissile material free detector with the same dimension as the fission chamber detec... The prototype neutron flux monitor consists of a high purity ^(235)U fission chamber detector and a'blank'detector,which is a fissile material free detector with the same dimension as the fission chamber detector to identify noise issues such as noise coming from gamma rays.The main parameters of the fission chamber assembly that have been measured in the laboratory are confirmed to approach the technological level of the International Thermonuclear Experimental Reactor(ITER)in the near future.This prototype neutron flux monitor will be further developed to become a neutron flux monitor suitable for the operation phase of D-D fusion on the ITER. 展开更多
关键词 neutron flux monitor fission chamber detector international thermonuclear experimental reactor(ITER) plateau characteristic curve discrimination threshold
在线阅读 下载PDF
Development of a data acquisition and control system for the International Thermonuclear Experimental Reactor neutron flux monitor 被引量:2
7
作者 Zihao LIU Xiang ZHOU +3 位作者 Renjie ZHU Li ZHAO Lingfeng WEI Zejie YIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第1期96-103,共8页
To satisfy high-precision,widc-rangc,and real-time neutron flux measurement requirements by the International Thermonuclear Experimental Reactor(ITF.R),a data acquisition and control system based on fission chamber de... To satisfy high-precision,widc-rangc,and real-time neutron flux measurement requirements by the International Thermonuclear Experimental Reactor(ITF.R),a data acquisition and control system based on fission chamber detectors and fast controller technology,has been developed for neutron flux monitor in ITER Equatorial Port#7.The signal processing units which arc based on a field programmable gate array and the PXI Express platform arc designed to realize the neutron flux measurement with I ms time resolution and a fast response less than 0.2 ms,together with real-time timestamps provided by a timing hoard.The application of the wide-range algorithm allows the system to measure up to 10^10cps with a relative error of less than 5%.Furthermore,the system is managed and controlled by a software based on the Experimental Physics and Industrial Control System,compliant with COntrol.Data Access and Communication architecture. 展开更多
关键词 neutron flux monitor data acquisition.CODAC F.PICS
在线阅读 下载PDF
Compact lithium-glass neutron beam monitor for SANS at CSNS 被引量:2
8
作者 Ke Zhou Jian-Rong Zhou +6 位作者 Yu-Shou Song Xiao-Juan Zhou Zhao-Yang Xie Gui-An Yang Yan-Feng Wang Yuan-Bo Chen Zhi-Jia Sun 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第9期165-170,共6页
A small-angle scattering neutron spectrometer for material research is under construction at the China Spallation Neutron Source. An intervening neutron beam monitor behind the sample is needed to measure the beam int... A small-angle scattering neutron spectrometer for material research is under construction at the China Spallation Neutron Source. An intervening neutron beam monitor behind the sample is needed to measure the beam intensity in order to reduce the measurement uncertainty caused by beam fluctuation. Considering the mobility requirement and limited space, we proposed a compact monitor using a type of lithium-glass scintillator provided by China Building Materials Academy. Its performance was studied experimentally using ^(252)Cf and ^(60)Co sources.The neutron light yield of the selected scintillator was measured to be 5:3 × 10~3 photons/neutron. The feasibility of n-gamma discrimination using the charge comparison method was verified. By using the Geant4 toolkit, themonitor was modeled with precise physical processes including neutron tracking, scintillation, and optical photon transmission. The gamma sensitivity and detection efficiency were investigated in the simulation. It was concluded that a 0.5-mm-thick lithium-glass scintillator with natural lithium is an appropriate choice to satisfy both the neutron detection efficiency and gamma elimination requirements. 展开更多
关键词 neutron beam monitor LITHIUM GLASS ngamma DISCRIMINATION Detection efficiency
在线阅读 下载PDF
Real-time wide-range neutron flux monitor for thorium-based molten salt reactor 被引量:2
9
作者 Xiang Zhou Zi-Hao Liu +2 位作者 Chao Chen Guo-Qing Huang Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第8期107-113,共7页
A novel full-digital real-time neutron flux monitor(NFM) has been developed for thorium-based molten salt reactor(TMSR).The system is based on the highspeed,parallel,and pipeline processing of the field programmable g... A novel full-digital real-time neutron flux monitor(NFM) has been developed for thorium-based molten salt reactor(TMSR).The system is based on the highspeed,parallel,and pipeline processing of the field programmable gate array as well as the high-stability controller area network platform.A measurement range of 10~8 counts per second is achieved with a single fission chamber by utilizing the normalization of the count and Campbell algorithms.With the advantages of using the measurement range,system integrity,and real-time performance,digital NFM has been tested in the Xi'an pulsed reactor fission experiments and was found to exhibit superior experimental performance. 展开更多
关键词 监视器 反应堆 流动 中子 熔融 宽范围 控制器区域网络 实时
在线阅读 下载PDF
Dynamic linear calibration method for a wide range neutron flux monitor system in ITER 被引量:4
10
作者 LI Shiping XU Xiufeng +2 位作者 CAO Hongrui YANG Qingwei YIN Zejie 《Nuclear Science and Techniques》 SCIE CAS CSCD 2013年第4期57-60,共4页
As a key part of the diagnosis system in the International Thermonuclear Experimental Reactor(ITER),the neutron flux monitor(NFM),which measures the neutron intensity of the fusion reaction,is a Counting-Campbelling s... As a key part of the diagnosis system in the International Thermonuclear Experimental Reactor(ITER),the neutron flux monitor(NFM),which measures the neutron intensity of the fusion reaction,is a Counting-Campbelling system with a large dynamic counting range.A dynamic linear calibration method is proposed in this paper to solve the problem of cross-over between the different counting and Campbelling channels,and improve the accuracy of the cross-calibration for long-term operation.The experimental results show that the NFM system with the dynamic linear calibration system can obtain the neutron flux of the fusion reactor in real time and realize the seamless measurement area connection between the two channels. 展开更多
关键词 动态非线性 监测系统 中子通量 校正方法 ITER 国际热核实验反应堆 聚变反应堆 组成部分
在线阅读 下载PDF
Days of “Zero” level geomagnetic activity accompanied by the high neutron activity and dynamics of some medical events—Antipodes to geomagnetic storms 被引量:1
11
作者 E. Stoupel E. S. Babayev +1 位作者 E. Abramson J. Sulkes 《Health》 2013年第5期855-861,共7页
The links of many medical-biological events with high levels of geomagnetic activity (GMA) are widely discussed. In recent years, several medical phenomena were described in inverse distribution by time with GMA. Also... The links of many medical-biological events with high levels of geomagnetic activity (GMA) are widely discussed. In recent years, several medical phenomena were described in inverse distribution by time with GMA. Also a concurrent to GMA and solar activity force-cosmic ray activity (CRA) and closely related high energy neutron and proton fluxes are studied as a forces dominating at low GMA and solar activity in relation to considered medical events. The aim of this study was to explore the distribution of some important medical events on days with “Zero” GMA levels, accompanied by high CRA (neutron activity). Medical event data of the Grand Baku region (more than 3 mln inhabitants), Azerbaijan, with daily distribution on the time 1 Dec. 2002-31 Dec. 2007 was compared to daily GMA Kp indices in general (Kp > 0, 1837 days) and 34 days daily GMA indices Kp = 0. Daily CRA data was also compared using neutron monitoring data from two stations. Daily averaged data and their standard deviations on the mentioned GMA levels were compared and statistical significance was established. Results revealed a significant rise in the number of emergencies (n = 1,567,576) and total deaths number (n = 46,360) at the days of “Zero” GMA level. These days were accompanied by significant rise of CRA (neutron activity). For Sudden Cardiac Deaths (SCD, n = 1615) and cerebral stroke (CVA, n =10,054) the increase achieved strong trend to significance level. Acute Myocardial Infarction occurrence (morbidity) and trauma were also absolutely more registered at days with “Zero” GMA level, despite the small number of such days. The average Infection numbers show an inverse relationship with absolutely high registry at the “Zero” GMA level days. Study linking environmental physical activity levels and the human medical data shows that geomagnetic field variations accompanied by the increased level of cosmic ray activity, can have either direct or indirect adverse effects on human health and physiology, even when the magnitude of the geomagnetic field disturbance is extremely small or even is equal to zero. On days of “Zero” daily Kp indices describing Geomagnetic Activity, accompanied by high Cosmic Ray Activity (neutron activity), more medical emergencies and total death number (daily) occurred. Sudden Cardiac Deaths and Cerebral Stroke numbers show a strong trend to significant rise. Absolute increase of number of Acute Myocardial Infarction and less Infections, not achieving statistical significance, was also observed. These results are additional data for considering Cosmic Ray Activity (neutron activity) as an additional factor involved in time distribution of human medical events. 展开更多
关键词 GEOMAGNETIC ACTIVITY Solar ACTIVITY Cosmic Ray ACTIVITY neutron monitor MORBIDITY Mortality
暂未订购
A study of PFBR auxiliary neutron source strength activation and its variability with respect to the neutron spectrum and 123Sb capture cross section
12
作者 G.Pandikumar D.Sunil Kumar +4 位作者 M.M.Shanthi Bagchi Subhrojit A.John Arul D.Venkata Subramanian Rajeev Ranjan Prasad 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第8期114-122,共9页
In fast reactors, the inherent neutron source strength is often insufficient for monitoring the reactor start-up operation with ex-core detectors. To increase the subcritical neutron flux, an auxiliary neutron source ... In fast reactors, the inherent neutron source strength is often insufficient for monitoring the reactor start-up operation with ex-core detectors. To increase the subcritical neutron flux, an auxiliary neutron source subassembly(SSA) is generally used to overcome this problem. In this study, the estimated neutron source strength and detector count rate of an antimony-beryllium-based SSA are obtained using the deterministic transport code DORT and Monte Carlo calculations. Because the antimony activation rate is a critical parameter, its sensitivity to the capture cross section and neutron flux spectrum is studied. The reaction cross section sensitivity is studied by considering data from different evaluated nuclear data files.It is observed that, because of the variation in the cross sections from different evaluated nuclear data files, the values of the saturation gamma(> 1.67 MeV) activity and neutron strength predicted by ORIGEN2 lie within ±2%.The obtained antimony activation rate and sensitivity to the neutron flux are partially validated by irradiating samples of antimony in the KAMINI reactor. The average onegroup capture cross sections of bare and cadmium-covered 123Sb samples obtained by the ratio method are 4.0 and 1.78 b, respectively. The results of the calculation predicting the activated neutron source strength as a function of operating time and sensitivity to the neutron spectrum in the irradiation region are also presented. 展开更多
关键词 Fast reactors neutron source Coremonitoring neutron and GAMMA transport Antimonyactivation Material depletion
在线阅读 下载PDF
基于TMSR-PNS的宽能区中子束流监测器的模拟研究
13
作者 陈怡 伍建辉 +3 位作者 邹春燕 胡继峰 陈金根 蔡翔舟 《核技术》 北大核心 2025年第10期102-112,共11页
针对钍基熔盐堆白光中子源(Thorium Molten Salt Reactor with a Particle and Neutron Source,TMSRPNS)在运行过程中出现中子束流掉束或打火导致的束流不稳定的问题,有必要设计研发一种具有高计数率、低中子束流影响、高中子/伽马甄别... 针对钍基熔盐堆白光中子源(Thorium Molten Salt Reactor with a Particle and Neutron Source,TMSRPNS)在运行过程中出现中子束流掉束或打火导致的束流不稳定的问题,有必要设计研发一种具有高计数率、低中子束流影响、高中子/伽马甄别性能的中子束流监测器。基于蒙特卡罗模拟软件Geant4,系统研究了薄膜塑料闪烁中子束流监测器的中子转换层厚度、闪烁体厚度,以及入射窗材料等关键参数对薄膜闪烁体的影响规律,分析结果表明:闪烁体中子转换层厚度约为2μm时具有相对合适的本征探测效率;闪烁体厚度为0.5 mm、甄别阈值为0.8 MeV时监测器具备γ射线不灵敏性能。同时,通过对比不同入射窗材料对于γ射线产生电子以及对中子散射的影响,选取电子产生较少且中子散射较小的铝作为入射窗材料。研究结果可为后续的中子束流监测器实物制备提供理论依据。 展开更多
关键词 白光中子源 中子束流监测器 GEANT4 薄膜闪烁体
原文传递
聚变堆中子通量测量电子学系统研制
14
作者 魏凌峰 赵丽 +4 位作者 袁国梁 杨青巍 刘子豪 朱人杰 温昕澄 《核聚变与等离子体物理》 北大核心 2025年第4期381-387,共7页
针对在国际热核聚变实验堆(ITER)运行参数下的聚变堆中子通量测量,设计并研制了一套具备一定耐辐照能力的宽量程中子通量监测(NFM)系统。该系统采用裂变室对聚变中子进行探测,后端电子设备主要由前置放大器、信号处理单元、高稳定性程... 针对在国际热核聚变实验堆(ITER)运行参数下的聚变堆中子通量测量,设计并研制了一套具备一定耐辐照能力的宽量程中子通量监测(NFM)系统。该系统采用裂变室对聚变中子进行探测,后端电子设备主要由前置放大器、信号处理单元、高稳定性程控电源和温度监测单元等组成。目前,NFM系统电子学原型部件已完成研制,完成了信号调理、鉴别、采样和处理的全链路调试。在HL-2A装置上对该系统的验证实验结果与预期的一致,表明该系统满足设计要求。 展开更多
关键词 聚变堆 中子通量监测 电子学部件
在线阅读 下载PDF
临界装置中子源系统设计及试验验证
15
作者 刘凯凯 杨历军 +6 位作者 梁淑红 张巍 周小平 肖启冬 王帅先 杨顺 周敏兰 《核科学与工程》 北大核心 2025年第3期435-441,共7页
中子源系统是临界装置的重要系统设备,起到启动反应堆和消除监测盲区的作用。中子源系统需具备两大功能:一是中子源的贮存和屏蔽;二是将中子源安全平稳地往返于屏蔽罐和堆芯指定位置之间。基于临界装置对中子源系统的需求,设计了一种机... 中子源系统是临界装置的重要系统设备,起到启动反应堆和消除监测盲区的作用。中子源系统需具备两大功能:一是中子源的贮存和屏蔽;二是将中子源安全平稳地往返于屏蔽罐和堆芯指定位置之间。基于临界装置对中子源系统的需求,设计了一种机电式系统,可安全平稳地将中子源从屏蔽罐输送至堆芯指定位置。通过检测钢丝绳对压力传感器的压力变化情况,实时判断系统是否发生故障;通过编码器与终端开关,可实时确定中子源位置。对此系统开展了试验验证,满足设计指标要求,并在临界装置上成功应用,结果证明其操作简单,可靠性高,重复性好,可快速发现故障并排除,具有非常好的实用价值。 展开更多
关键词 中子源 中子源系统 临界装置 消除监测盲区 中子源输送 压力传感器
在线阅读 下载PDF
中子剂量监测技术现状与发展趋势
16
作者 李雨涵 沈春霞 +1 位作者 来永芳 叶二雷 《现代应用物理》 2025年第5期15-24,共10页
中子作为一种重要的间接致电离辐射,在科学研究、工业、医疗及国防军事领域具有广泛应用。由于中子与人体内氢原子的相互作用可能引发严重的辐射损伤,因此,中子剂量的监测至关重要。本文系统综述了当前中子剂量监测技术的研究进展,重点... 中子作为一种重要的间接致电离辐射,在科学研究、工业、医疗及国防军事领域具有广泛应用。由于中子与人体内氢原子的相互作用可能引发严重的辐射损伤,因此,中子剂量的监测至关重要。本文系统综述了当前中子剂量监测技术的研究进展,重点介绍了气体探测器、闪烁体探测器、半导体探测器、固体径迹探测器及热释光剂量计5种主要探测器,详细讨论了其工作原理、优势、不足及适用场景。同时,比较了实测数据评估法、理论计算评估法和蒙特卡罗模拟评估法3种中子剂量评估方法,指出了各自的优点、缺点及适用范围。随着核科学技术的发展,特别是中子应用领域的扩展和聚变能源研究的进步,对中子剂量监测提出了更高要求。未来发展趋势将聚焦于提升测量精度和灵敏度,尤其是在复杂辐射场中的性能表现。通过新型材料的研发,有望进一步增强探测器的能量分辨率和抗干扰能力,满足特殊环境下的辐射监测需求,为辐射防护提供更为可靠的技术支撑。这些技术进展对于保障公共安全、推动相关科技发展具有重要意义。 展开更多
关键词 中子剂量 剂量探测技术 剂量评估方法
在线阅读 下载PDF
广西甘蔗种植区遥测土壤水分站监测应用现状
17
作者 周坤论 匡昭敏 +3 位作者 李欣欣 陶伟 莫妘捷 朱泳桦 《甘蔗糖业》 2025年第4期19-28,共10页
为科学管理甘蔗种植、提升甘蔗产量和品质,目前广西气象部门在甘蔗种植区建设了8套遥测土壤水分站,实现土壤水分和气象要素变化实时监测,推动智慧农业高质量发展。本文结合该观测系统建设与运行现状,重点分析宇宙射线中子法(CRNP)测量... 为科学管理甘蔗种植、提升甘蔗产量和品质,目前广西气象部门在甘蔗种植区建设了8套遥测土壤水分站,实现土壤水分和气象要素变化实时监测,推动智慧农业高质量发展。本文结合该观测系统建设与运行现状,重点分析宇宙射线中子法(CRNP)测量原理、系统组成、影响因素、监测现状及数据可用性等。结果显示,除雁山遥测土壤水分站外,其余7站到报率均超90%;由于南宁、贵港、百色、玉林、沙塘、雁山6地因土壤水分设备尚未校准,数据质量不作评价;分析结果显示,来宾、扶绥遥测土壤水分站设备灵敏度高,精度优于国家级土壤水分站,能更精准反映区域土壤墒情变化。随着甘蔗气象观测站网的完善、观测数据质量的提升及管理体系健全,未来,遥测土壤水分站在甘蔗产业保障服务中具有重要的应用价值和发展潜力。 展开更多
关键词 宇宙射线中子法 甘蔗种植区 土壤水分 监测 应用
在线阅读 下载PDF
面向加速器中子源的辐射安全联锁系统设计
18
作者 梁君筱 梁立振 +3 位作者 圣宗强 熊绪文 李帅 胡阳 《哈尔滨商业大学学报(自然科学版)》 2025年第2期192-198,共7页
中子发生器在运行过程中,会产生大量的中子与γ射线.为了防止有人员误入辐射区域,建立了基于冗余控制技术的人员辐射安全联锁系统.采用分布式架构设计了中子源辐射安全联锁系统.基于可编程逻辑控制器PLC与LD(Ladder Diagram)实现了现场... 中子发生器在运行过程中,会产生大量的中子与γ射线.为了防止有人员误入辐射区域,建立了基于冗余控制技术的人员辐射安全联锁系统.采用分布式架构设计了中子源辐射安全联锁系统.基于可编程逻辑控制器PLC与LD(Ladder Diagram)实现了现场传感器的控制,并通过以太网通信实现人机交流.采用C#语言开发了辐射安全联锁监控程序,实现现场加速器、各传感器的实时监测,并根据实现信号判断是否可以启动或关闭加速器以保证人员安全.设计的辐射安全联锁系统可以通过清场在实验前防止有闲散人员在现场逗留,实验中遇到紧急事件切断中子源束流,实验后在辐射剂量低于指定剂量前不允许人员进入,保障工作人员的人身安全,运行稳定可靠. 展开更多
关键词 中子源 实时监控 PLC 冗余控制 辐射安全联锁系统
在线阅读 下载PDF
基于发射体反应解析的自给能中子探测器长期性能演变分析
19
作者 王天喜 李俊 +2 位作者 别业旺 李钊同 李克亮 《核电子学与探测技术》 北大核心 2025年第11期1742-1749,共8页
自给能中子探测器(Self-Powered Neutron Detector,SPND)的长期性能对先进反应堆的安全运行具有重要意义。然而,当前相关研究多依赖于计算成本较高的蒙特卡洛模拟或在役实验数据,缺乏统一的解析理论框架。本研究采用发射体反应解析方法... 自给能中子探测器(Self-Powered Neutron Detector,SPND)的长期性能对先进反应堆的安全运行具有重要意义。然而,当前相关研究多依赖于计算成本较高的蒙特卡洛模拟或在役实验数据,缺乏统一的解析理论框架。本研究采用发射体反应解析方法,通过核反应与衰变方程,推导得到铑、钒、钴三种SPND灵敏度随时间及累积中子注量演变的数学模型。研究结果显示,铑SPND的灵敏度呈高燃耗驱动的指数衰减趋势;钒SPND因核反应截面极低,在整个服役期内灵敏度近乎恒定,其寿命主要由材料耐受性决定;钴SPND则受制于因燃耗产物钴-60累积造成的本底信号污染,为此,本研究引入了“信息寿命”概念进行量化。本研究揭示了主流SPND长期性能内在物理规律,为SPND的可靠性评估及反应堆堆芯在线监测提供了理论参考。 展开更多
关键词 自给能中子探测器(SPND) 长期性能 灵敏度 堆芯监测
在线阅读 下载PDF
中子发生器在煤质在线检测中的应用与安全探讨
20
作者 黎润华 彭文斌 +2 位作者 李玮衡 崔晓蓬 梁潇栩 《绿色科技》 2025年第16期165-169,共5页
针对传统煤质检测方法时效性差、X射线法对轻元素(C/H/O)检测灵敏度不足的问题,以广西壮族自治区某水泥厂P385型中子发生器煤质在线检测系统为对象,采用脉冲快热中子分析技术(PFTNA),实现煤质全元素成分的在线分析,并通过现场监测与剂... 针对传统煤质检测方法时效性差、X射线法对轻元素(C/H/O)检测灵敏度不足的问题,以广西壮族自治区某水泥厂P385型中子发生器煤质在线检测系统为对象,采用脉冲快热中子分析技术(PFTNA),实现煤质全元素成分的在线分析,并通过现场监测与剂量估算相结合的方法,系统评估了14 MeV中子及次级γ射线对周围环境的辐射影响,得出该类设备可推广使用的结论,并探讨该类设备在应用中需注意的辐射安全事项,为该类设备的广泛应用提供参考。 展开更多
关键词 中子发生器 中子辐射 Γ射线 煤质在线检测 监测 评价
在线阅读 下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部