期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Cycle performance studies on a new HFC-161/125/143a mixture as an alternative refrigerant to R404 被引量:4
1
作者 Xiao-hong HAN Yu QIU +3 位作者 Ying-jie XU Men-yuan ZHAO Qin WANG Guang-ming CHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2012年第2期132-139,共8页
In this paper, a new ternary non-azeotropic mixture of HFC-161/125/143a (0.15/0.45/0.40 in mass fraction), as a promising mixed refrigerant to R404A, is presented. The ozone depletion potential (ODP) of the new re... In this paper, a new ternary non-azeotropic mixture of HFC-161/125/143a (0.15/0.45/0.40 in mass fraction), as a promising mixed refrigerant to R404A, is presented. The ozone depletion potential (ODP) of the new refrigerant is zero and its basic thermodynamic properties are similar to those of R404A, but its global warming potential (GWP) is much smaller than those of R507A and R404A. Meanwhile, theoretical calculations show that, under the working condition 1 (the average evaporation temperature: -23℃, the average condensing temperature: 43℃, the superheat temperature: 28℃, the subcooling temperature: 5 ℃), the volumetric refrigerating effect and specific refrigerating effect of the new mixture are 2.33% and 15.48% higher, re- spectively, than those of R404A. The coefficient of performance (COP) of the new mixture is 5.19% higher than that of R404A and the pressure ratio of the new mixture is 0.82% lower than that of R404A. Equally, under the working condition II (the average evaporation temperature: -40℃, the average condensing temperature: 35℃, the superheating temperature: 30 ~C, the subcooling temperature: 5℃), the volumetric refrigerating effect and specific refrigerating effect of the new mixture are 2.24% and 20.58% higher, respectively, than those of R404A. The COP of the new mixture is 4.60% higher than that of R404A and the pressure ratio of the new mixture is similar to that of R404A. The performances of the new mixture and R404A are compared in a vapor compressor refrigeration apparatus originally designed for R404A under several working conditions (condensing temperatures: 35-45℃, evaporation temperatures: -40--20℃). Experimental results show that the new mixture can obtain a higher COP, by 6.3% to 12.1%, and a lower pressure ratio, by 1.8% to 6.6%, compared to R404A; although the discharge temperature of the new mixture is slightly higher than that of R404A. The advantages of the new mixture will be further verified in the actual system. 展开更多
关键词 Alternative refrigerant MIXTURE Cycle nerformance. R404A HFC-161
原文传递
Experimental investigation of an adjustable ejector for CO_2 heat pump water heaters 被引量:3
2
作者 Guang-ming CHEN Li-xia LIANG Li-ming TANG Xiao-xiao XU Zhi-jiang ZHU Qi CHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2009年第11期1678-1682,共5页
An adjustable ejector expansion device for a CO2 heat pump water heater (HPWP) is proposed to improve the system performance. It has been designed to investigate experimentally the effects of the motive nozzle throat ... An adjustable ejector expansion device for a CO2 heat pump water heater (HPWP) is proposed to improve the system performance. It has been designed to investigate experimentally the effects of the motive nozzle throat area of the ejector, entrained flow pressure, back pressure and primary flow pressure on the entrainment ratio. Experiments based on different motive nozzle throat areas were conducted and the results of the prototype ejector using CO2 as working fluid are presented. The results show that an adjustable ejector can achieve high performance and work well in a wide range of working conditions. 展开更多
关键词 Adjustable elector System nerformance CO2 heat oumo water heater (HPWH) Entrainment ratio
原文传递