The multi-voltage-level DC distribution network(MVL-DC-DN)is a promising network for efficiently integrat ing rapidly growing DC loads,and fast-growing load demand would bring a challenge to the MVL-DC-DN in terms of ...The multi-voltage-level DC distribution network(MVL-DC-DN)is a promising network for efficiently integrat ing rapidly growing DC loads,and fast-growing load demand would bring a challenge to the MVL-DC-DN in terms of the maximum loadability.This paper considers the DC electric spring(DC-ES)as a novel candidate flexible resource for en hancing the maximum loadability of the MVL-DC-DN,and pro poses an evaluation method for the maximum loadability.First ly,with the consideration of device constraints,the impact that the DC-ES on the maximum loadability of the DC distribution network(DC-DN)is analyzed via a simplified equivalent cir cuit.Subsequently,the power flow(PF)model of an MVL-DCDN with DC-ESs is established.Finally,a method based on con tinuation power flow(CPF)for evaluating the maximum load ability of an MVL-DC-DN with DC-ESs is proposed.During the evaluation,limitations of the DC-ES and the DC transform er(DCT)are considered.The consideration of the practical con straints avoids the overestimation of the maximum loadability.The case study verifies the effectiveness of the proposed method.展开更多
基金supported in part by the National Natural Science Foundation of China(No.52077017).
文摘The multi-voltage-level DC distribution network(MVL-DC-DN)is a promising network for efficiently integrat ing rapidly growing DC loads,and fast-growing load demand would bring a challenge to the MVL-DC-DN in terms of the maximum loadability.This paper considers the DC electric spring(DC-ES)as a novel candidate flexible resource for en hancing the maximum loadability of the MVL-DC-DN,and pro poses an evaluation method for the maximum loadability.First ly,with the consideration of device constraints,the impact that the DC-ES on the maximum loadability of the DC distribution network(DC-DN)is analyzed via a simplified equivalent cir cuit.Subsequently,the power flow(PF)model of an MVL-DCDN with DC-ESs is established.Finally,a method based on con tinuation power flow(CPF)for evaluating the maximum load ability of an MVL-DC-DN with DC-ESs is proposed.During the evaluation,limitations of the DC-ES and the DC transform er(DCT)are considered.The consideration of the practical con straints avoids the overestimation of the maximum loadability.The case study verifies the effectiveness of the proposed method.