AIM:To assess the visual electrophysiological outcomes in children with functional amblyopia who exhibited poor response to conventional treatment.METHODS:Twenty-one children with functional amblyopia,aged 5.7±2....AIM:To assess the visual electrophysiological outcomes in children with functional amblyopia who exhibited poor response to conventional treatment.METHODS:Twenty-one children with functional amblyopia,aged 5.7±2.1y(range:4-10y),underwent comprehensive ophthalmic and refractive evaluations.Spectral domain-optical coherence tomography(SD-OCT)and multifocal electroretinography(mfERG)were conducted to analyze the macular retinal thickness and the first-order response P1 ring of the mfERG in the amblyopic eye(AE)compared to the fellow good eye(GE).RESULTS:Initially,visual acuity in the AE ranged from 20/800 to 20/40,while the GE exhibited a range of 20/25 to 20/20(P<0.01).After 6mo of treatment,17 patients demonstrated improved visual acuity in the AE to 20/50 or better,while 4 children showed no improvement.SD-OCT revealed comparable macular and optic disc structures between the AE and GE.Prior to treatment,the mfERG P1 ring amplitude was significantly reduced in the AE compared to GE(P<0.05).The AE/GE ratio of P1 ring amplitude showed significant improvement post-treatment.However,a smaller AE/GE ratio before treatment was associated with poorer improvement post-treatment.CONCLUSION:In the management of functional amblyopia,a thorough assessment of amblyopic eye examinations is crucial.Approximately 20%of amblyopic eyes may not achieve significant improvement in visual acuity,despite the absence of detectable organic retinal abnormalities.mfERG may reveal underlying abnormalities.Integrating mfERG into initial assessments or treatment follow-ups can aid in identifying potential hidden retinal defects and predicting the prognosis of the amblyopic eye.展开更多
AIM:To evaluate the influence of ocular biometric parameters on the performance of actual near-add power in the spectacle plane of multifocal intraocular lenses(MIOLs).METHODS:This retrospective study defined predicti...AIM:To evaluate the influence of ocular biometric parameters on the performance of actual near-add power in the spectacle plane of multifocal intraocular lenses(MIOLs).METHODS:This retrospective study defined prediction error(PE)as the difference between actual postoperative near-add power and manufacturer-predicted values.Linear regression assessed PE correlations with axial length(AL),mean keratometry(K),pupil size,anterior chamber depth(ACD),lens thickness(LT),ACD+0.5×LT,and back-calculated IOL power.Differences in PE across MIOLs types,AL,K,pupil size,ACD,LT,ACD+0.5×LT,and back-calculated IOL power groups were compared.RESULTS:Totally 250 eyes of 250 patients(116 males and 134 females,mean age 56.22±12.31y)who underwent phacoemulsification with MIOL implantation were reviewed.PE showed no significant correlation with most parameters but had a weak positive correlation with LT.The mean predicted error(MPE)in the AL≤22,26–27,and 27–28 mm groups were 0.83(0.51,1.01)D,0.78(0.51,1.07)D,and 0.72(0.57,0.94)D respectively(P<0.001).The MPE in the K between the 45–46 D groups was 0.78(0.37,1.07)D(P=0.0004).The MPE in the LT between the 4.5–5.0 mm groups and≥5 mm was 0.72(0.50,1.01)D and 0.72(0.51,1.01)D respectively(P<0.001).The MPE in the back-calculated IOL power≥25 D was 0.86(0.60,1.01)D(P<0.001).CONCLUSION:Although there is no significant linear relationship between near-add power and most ocular biometry parameters,and specific segments of AL,K,LT,and IOL power have a significant impact on the near-add power of MIOLs.These factors should be taken into account in preoperative evaluations.展开更多
●Multiple evanescent white dot syndrome(MEWDS)is a rare fundus disease,characterized by acute vision loss and visual field defects.Many previous studies have explained the possible pathogenesis and clinical features ...●Multiple evanescent white dot syndrome(MEWDS)is a rare fundus disease,characterized by acute vision loss and visual field defects.Many previous studies have explained the possible pathogenesis and clinical features of primary MEWDS.However,as the number of reported cases increases,secondary MEWDS occurs in other related retinal diseases and injuries,exhibiting some special characteristics.The associated retinal diseases include multifocal choroiditis/punctate inner choroidopathy(MFC/PIC),acute zonal occult outer retinopathy,best vitelliform macular dystrophy,pseudoxanthoma elasticum,and ocular toxoplasmosis.The related retinal injury is laser photocoagulation,surgery,and trauma.Although primary MEWDS often have a self-limiting course,secondary MEWDS may require treatment in some cases,according to the severity of concomitant diseases and complications.Notably,MEWDS secondary to MFC/PIC that is prone to forming choroidal neovascularization and focal choroidal excavation,needs positive treatment with corticosteroids.The possible underlying pathogenesis of secondary MEWDS is the exposure of choroidal antigen after the disruption of Bruch’s membrane.The MEWDS-related features in secondary MEWDS are still evanescent under most circumstances.Its prognosis and treatment depend on the severity of complications.Current studies propose that the etiology is associated with immune factors,including viral infection,inflammation in choroid and Bruch’s membrane,and antigen exposure caused by retinal and/or choroidal insults.More pathogenic studies should be conducted in the future.Accurate diagnosis for secondary MEWDS could benefit patients in aspects of management and prognosis.展开更多
BACKGROUND The incidence of multiple primary carcinomas(MPC)varies greatly,ranging from 0.73%to 11.70%in foreign countries,with duo-duplex carcinoma being the most common,trio-duplex carcinoma and above being rare,and...BACKGROUND The incidence of multiple primary carcinomas(MPC)varies greatly,ranging from 0.73%to 11.70%in foreign countries,with duo-duplex carcinoma being the most common,trio-duplex carcinoma and above being rare,and simultaneous multigenic carcinoma being even rarer,accounting for 18.4%to 25.3%of the incidence of MPC.However,there is no report regarding patients presenting with simultaneous dual-origin carcinoma of the liver and colon and heterochronous pancreatic cancer.CASE SUMMARY We report a special case of multifocal carcinoma,in which one patient had a medical condition of primary liver and colon cancer and pancreatic cystadenocarcinoma 2 years after surgery.Through aggressive advanced fluorescent laparoscopic techniques,standardized immunotherapy,targeting,and chemotherapy,a better prognosis and a desirable survival period were achieved for the patient.CONCLUSION There is a need to clarify the nature of MPC through advanced surgical means to ensure better diagnosis and treatment.展开更多
This case is a 49-year-old female patient who presented with suspected eustachian tube dysfunction symptoms that were refractory to medical treatment. She presented with conductive hearing loss and aural fullness on t...This case is a 49-year-old female patient who presented with suspected eustachian tube dysfunction symptoms that were refractory to medical treatment. She presented with conductive hearing loss and aural fullness on the left. A physical exam revealed an epitympanic fleshy mass in the middle ear with effusion. Imaging with MRI and CT showed opacification of the epitympanum with surrounding bony demineralization bilaterally left greater than right and significant thinning versus dehiscence of the tegmen mastoideum and tympani on the left with only thinning of the tegmen on the right. An MR temporal bone with and without contrast, demonstrated enhancement of the left middle ear extending to the tegmen and corresponding enhancement of the dura along the floor of the left middle cranial fossa as well as extending along foramen ovale into the infratemporal fossa. There was to a lesser degree similar appearance on the right. A biopsy of the middle ear mass on the left revealed meningioma. This case highlights the need to widen your differential with common symptoms when they are refractory to treatment.展开更多
We present the case of a 29-year-old patient with a history of abdominal pain and vomiting.Based on wireless video capsule findings he was previously diagnosed with ileal Crohn's disease at a different institution...We present the case of a 29-year-old patient with a history of abdominal pain and vomiting.Based on wireless video capsule findings he was previously diagnosed with ileal Crohn's disease at a different institution,although the clinical and radiological picture was not typical and the response to corticosteroids was poor.We performed a single-balloon enteroscopy showing a short,ulcerous stenosis 50 cm proximal from Bauhin's valve.The endoscopic and clinical histopathological findings were compatible with cryptogenic multifocal ulcerous stenosing enteritis(CMUSE).High dose corticosteroids were again started,without effect.The monoclonal tumor necrosis factor-α(TNF-α) antibody infliximab was added to the medical therapy.After induction therapy,both clinical and endoscopic amelioration was obtained.Larger case studies are needed to confirm the efficacy of TNF-α inhibition in steroid refractory CMUSE.展开更多
AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patie...AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patients who underwent unilateral cataract surgery,followed by implantation of rotationally asymmetric MIOLs were included.Distance and near visual acuity outcomes,intraocular aberrations,preferred reading distances,preoperative and postoperative refractive errors,mesopic and photopic pupil diameters,and the mesopic and photopic kappa angles were assessed.Patients were also administered a satisfaction survey.Photic phenomena were graded by questionnaire.Independent-related factors were identified by correlation and bivariate logistic regression analyses.RESULTS: The distance from the photopic to the mesopic pupil center(pupil center shift) was significantly associated with glare/halo symptoms [odds ratio(OR)=2.065,95% confidence interval(CI)=0.916-4.679,P=0.006] and night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007).The preoperative photopic angle kappa was significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041).The photopic angle kappa was also significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041) and with night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007) in patients implanted with rotationally asymmetric MIOLs.CONCLUSION: A large pupil center shift and misalignment between the visual and pupillary axis(angle kappa)may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs.展开更多
Extraintestinal manifestations occur in about one-third of patients living with inflammatory bowel disease(IBD) and may precede the onset of gastrointestinal symptoms by many years. Neurologic disorders associated wit...Extraintestinal manifestations occur in about one-third of patients living with inflammatory bowel disease(IBD) and may precede the onset of gastrointestinal symptoms by many years. Neurologic disorders associated with IBD are not frequent, being reported in 3% of patients, but they often represent an important cause of morbidity and a relevant diagnostic issue. In addition, the increasing use of immunosuppressant and biological therapies for IBD may also play a pivotal role in the development of neurological disorders of different type and pathogenesis. Hence, we provide a complete and profound review of the main features of neurological complications associated with IBD, with particular reference to those related to drugs and with a specific focus on their clinical presentation and possible pathophysiological mechanisms.展开更多
Ultrathin flat metalenses have emerged as promising alternatives to conventional diffractive lenses,offering new possibilities for myriads of miniaturization and interfacial applications.Graphene-based materials can a...Ultrathin flat metalenses have emerged as promising alternatives to conventional diffractive lenses,offering new possibilities for myriads of miniaturization and interfacial applications.Graphene-based materials can achieve both phase and amplitude modulations simultaneously at a single position due to the modification of the complex refractive index and thickness by laser conversion from graphene oxide into graphene like materials.In this work,we develop graphene oxide metalenses to precisely control phase and amplitude modulations and to achieve a holistic and systematic lens design based on a graphene-based material system.We experimentally validate our strategies via demonstrations of two graphene oxide metalenses:one with an ultra-long(~16λ)optical needle,and the other with axial multifocal spots,at the wavelength of 632.8 nm with a 200 nm thin film.Our proposed graphene oxide metalenses unfold unprecedented opportunities for accurately designing graphene-based ultrathin integratable devices for broad applications.展开更多
AIM: To compare the clinical outcomes of a variety of multifocal intraocular lenses(MIOLs) in patients diagnosed with presbyopia or cataracts. METHODS: This clinical trial study included 141 patients(282 eyes) with di...AIM: To compare the clinical outcomes of a variety of multifocal intraocular lenses(MIOLs) in patients diagnosed with presbyopia or cataracts. METHODS: This clinical trial study included 141 patients(282 eyes) with different MIOLs implantation. The Symfony(60 eyes), the Re STOR(100 eyes), the AT LISAtri(60 eyes), and the Pan Optix(62 eyes) intraocular lenses were evaluated in this prospective interventional study. The near, intermediate, and distant visual acuities, contrast sensitivity, and defocus curve were measured as valid criteria. To statistically analyze the results, we used the Statistical Package for Social Science software, the non-parametric Wilcoxon signed-rank t, the one-way analysis of variance and the Tukey’s post-hoc test in our analysis. Moreover, we conducted a detailed literature search on the Pub Med database in English about MIOLs, in total 59 studies were included in this review article.RESULTS: The four approaches did not show any significant difference in the best-corrected distance visual acuity(P>0.05). The defocus curves at the contrast of 100% showed that trifocal IOLs had better intermediate performance than the bifocal IOL(P<0.05). There were no statistically significant differences between AT LISAtri and Pan Optix lenses for visual acuity at all distances. The eyes with Pan Optix, Symfony, and AT LISAtri IOL showed better contrast sensitivity than those Re STOR at spatial frequencies of 1, 3, and 6 cpd in photopic and mesopic conditions(P<0.001). CONCLUSION: All four groups of the multifocal lenses were satisfying in terms of distance and near vision. Also, the group of trifocal lenses led to satisfactory outcomes in intermediate vision, without degradation in quality of vision.展开更多
·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ...·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ·METHODS: Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular and binocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) for distance, intermediate and near, spherical aberration (SA), contrast and glare sensitivity, near point refractive power, uncorrected and best corrected near stereoscopic acuity (NSA). Patient satisfaction was assessed by a questionnaire. ·RESULTS:Threemonthspostoperatively,themonocular and binocular UCVA and DCVA at near of Tecnis ZMA00 were significantly better than other two groups. The mean SA for 5.0mm optical zone in Tecnis ZMA00 and Tecnis ZA9003 was significantly lower than that in Akreos Adapt. Mean contrast sensitivity and glare sensitivity were better for Tecnis ZA9003 group than for other two groups. Patients with Tecnis ZMA00 had higher monocular and binocular near point refractive power and uncorrected NSA than monofocal groups. The patients in Tecnis ZMA00 had higher mean values for halo compared with other two groups. ·CONCLUSION: Tecnis ZMA00 provided better near VA and uncorrected NSA and higher near point refractive power than monofocal IOLs and patients were spectacle independent. The IOLs with Tecnis aspheric design improved contrast and glare sensitivity. Patients with Tecnis ZMA00 reported more disturbances on visual phenomena of halo. ·展开更多
We describe common and less common diseases that can cause magnetic resonance signal abnormalities of middle cerebellar peduncles(MCP), offering a systematicapproach correlating imaging findings with clinical clues an...We describe common and less common diseases that can cause magnetic resonance signal abnormalities of middle cerebellar peduncles(MCP), offering a systematicapproach correlating imaging findings with clinical clues and pathologic mechanisms. Myelin abnormalities, different types of edema or neurodegenerative processes, can cause areas of abnormal T2 signal, variable enhancement, and patterns of diffusivity of MCP. Pathologies such as demyelinating disorders or certain neurodegenerative entities(e.g., multiple system atrophy or fragile X-associated tremor-ataxia syndrome) appear to have predilection for MCP. Careful evaluation of concomitant imaging findings in the brain or brainstem; and focused correlation with key clinical findings such as immunosuppression for progressive multifocal leukoencephalopahty; hypertension, post-transplant status or high dose chemotherapy for posterior reversible encephalopathy; electrolyte disorders for myelinolysis or suspected toxic-drug related encephalopathy; would yield an appropriate and accurate differential diagnosis in the majority of cases.展开更多
To investigate the characteristic radiologic findings of cryptogenic multifocal ulcerous stenosing enteritis (CMUSE) which can be differentiated from other similar bowel disease and to assess their clinical behavior. ...To investigate the characteristic radiologic findings of cryptogenic multifocal ulcerous stenosing enteritis (CMUSE) which can be differentiated from other similar bowel disease and to assess their clinical behavior. METHODSTwenty pathologically and clinically confirmed CMUSE patients (males:females = 8:12; mean age: 40.4 years) between March 2002 and August 2015 from seven academic centers in South Korea were retrospectively reviewed. We evaluated small bowel series (SBS; n = 25), computed tomography (CT) enterography (n = 21), magnetic resonance (MR) enterography (n = 2), and abdominopelvic CT (n = 18) images, focusing on enteric and perienteric manifestations. Any change in radiologic features during follow-up period was recorded. We evaluated clinical data including presenting symptoms, laboratory finding and presence of relapse from electronic medical records. Histopathologic findings were also evaluated. RESULTSThe main symptoms were abdominal pain (n = 12) and anemia (n = 10). All patients showed small bowel strictures (n = 52, mean: 2.6 per patient) on initial CT/MR, located in the ileum (n = 47) or jejunum (n = 5). Strictures showed short-length (mean: 10.44 mm) and circumferential bowel wall thickening (mean: 5.56 mm) with layered enhancement (n = 48) that were also noted on initial SBS (n = 36) with shallow ulcers (n = 10). Some ulcerative lesions or wall thickening progressed into strictures on follow-up SBS/CT, and some strictures revealed recurrent ulceration on follow-up SBS. There were no penetrating disease features like fistula or abscess and no gastrointestinal tract involvement except the small bowel. Nine patients experienced disease recurrence (median relapse-free period: 32 mo) even post-operatively. Histopathologic features of surgically resected specimens were characterized as multiple superficial ulcerations confined to mucosa or submucosa and multiple strictures. CONCLUSIONUnder characteristic radiologic findings with multiple short-segmental strictures and/or shallow ulcers of the small intestine, CMUSE should be considered when assessing patients with recurrent abdominal pain and anemia.展开更多
Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they a...Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they are associated with a higher prevalence of dysphotopsia symptoms that is one of the most common causes of patient dissatisfaction. Neuroadaptation seems to play a major role in the optimal adaptation to multifocal IOLs. In this context, the development of strategies that facilitate the neuroadaptation process to multifocality might be an effective strategy to reduce patients' dissatisfaction. Video games have been proved to be effective for the improvement of visual acuity and for the promotion of neuroplasticity in elderly subjects and other populations with cortical-related visual impairment. This narrative review highlights the physiological potential of video games as a perceptual strategy to improve visual acuity and promote neuroplasticity in patients using multifocalIOLs, although research is still needed to confirm these benefits in this specific population, with only one comparative study to this date providing evidence of them.展开更多
AIM: To evaluate the effect of prophylactic administration of nepafenac in prevention of macular edema occurring in diabetic patients after phacoemulsification and to investigate the correlation between optical cohere...AIM: To evaluate the effect of prophylactic administration of nepafenac in prevention of macular edema occurring in diabetic patients after phacoemulsification and to investigate the correlation between optical coherence tomography(OCT) foveal thickness and multifocal electroretinogram(MF-ERG) parameters.METHODS: The study included two groups. Group 1 included 50 diabetic patients with senile cataract(50 eyes, 30 females, 20 males, aged 55±7 y) received nepafenac 0.1% eye drop. Group 2 included another 50 diabetic patients with senile cataract(50 eyes, 22 female, 28 males, aged 53.8±8 y) did not receive nepafenac. All patients were followed up for 3 mo postoperatively. OCT and MF-ERG were done preoperative and at 1 wk, 1, 2 and 3 mo.RESULTS: The mean foveal thickness was statistically significantly lower in Group 1. Five eyes in Group 2 developed clinical cystoid macular oedema(CMO)(10%), and no patients in Group 1 developed central macular thickening more than 50 μm. There were insignificant differences in MF-ERG amplitudes and latencies between the two groups except in the five eyes that developed CMO, there statistically significant reduction of MF-ERG amplitude with increase in foveal thickness. CONCLUSION: Perioperative nepafenac reduces the incidence of CMO following uncomplicated phacoemulsification significantly. Nepafenac has no side effects.展开更多
AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification...AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification and implantation with the SBL-3 segmented multifocal IOL between January 1,2017 and January 31,2019 were included in this retrospective study.Preoperative biometry measurements were obtained using an IOL Master.Manifest refraction was performed at least 4 wk postoperatively.Accuracy of the eight formulas[Barrett Universal II,Emmetropia Verifying Optical(EVO),Haigis,Hill-RBF 2.0,Hoffer Q,Holladay 1,Kane,and SRK/T]was analyzed.RESULTS:Using current lens constants,all formulas exhibited errors of slight myopic shift in refractive prediction.The Barrett Universal II formula had a significantly lower median absolute error(MedAE)than did Holladay 1(P=0.02),Kane(P=0.001)and Hill-RBF 2.0(P<0.001)formulas.The Haigis formula had a lower MedAE value than did the Hill-RBF 2.0 formula(P=0.005).Differences in MedAE values among SRK/T,EVO and Hoffer Q formulas were not significant.After optimizing lens constants,the MedAE values of all formulas were reduced;significant changes were noted for EVO(P=0.022),Haigis(P=0.048);Hill-RBF 2.0(P=0.014),Holladay 1(P=0.045)and Kane(P=0.022)formulas.All formulas performed equally well after optimization of lens constants(P=0.203).CONCLUSION:All eight formulas tend to result in a myopic shift when using current lens constants.Optimized lens constants improve the accuracy of these formulas among adult Chinese patients.展开更多
AIM: To compare visual quality in cataract patients with low corneal astigmatism who underwent intraocular lens(IOL) implantation, and evaluate effects of low levels of astigmatism on visual outcomes in multifocal pse...AIM: To compare visual quality in cataract patients with low corneal astigmatism who underwent intraocular lens(IOL) implantation, and evaluate effects of low levels of astigmatism on visual outcomes in multifocal pseudophakic eyes.METHODS: This retrospective review of clinical records comprised patients with preoperative regular corneal astigmatism of 0.75-1.0 diopters(D) with-the-rule or 0.5-0.75 D against-the-rule who had uneventful cataract surgery and AcrySof IQ ReSTOR Toric-2 IOL(ART2) or AcrySof IQ ReSTOR IOL(ReSTOR) implantation. Retrospective data collection included postoperative ART2 axis rotation, uncorrected astigmatism, uncorrected entire visual acuities, distance corrected entire visual acuities, average modulation transfer function(aMTF), Strehl ratio(SR), spectacle independence, and patient satisfaction between groups.RESULTS: Mean ART2 axis rotation was 3.12°±0.70°. No secondary surgery was required to realign IOL axis. Residual astigmatism values were-0.18±0.07 D and-0.91±0.25 D in groups ART2 and ReSTOR(P<0.05). Three months postoperatively, the mean uncorrected distant, intermediate, and near visual acuities of group A were 0.01±0.05, 0.05±0.07, 0.02±0.07 logMAR, respectively; these were better than those of group R, which were 0.08±0.06, 0.15±0.12, and 0.09±0.08 logMAR, respectively(P<0.05). aMTF, SR, and spectacle independence rates were not significantly different. All patients were satisfied with postoperative results.CONCLUSION: ART2 is more suitable than ReSTOR for cataract patients with regular corneal astigmatism 0.75-1.0 D with-the-rule or 0.5-0.75 D against-the-rule.展开更多
AIM:To evaluate clinical outcomes of unilateral implantation of a diffractive multifocal intraocular lens(IOL)in patients with contralateral monofocal IOL.METHODS:Twenty-two patients who already had implantation of a ...AIM:To evaluate clinical outcomes of unilateral implantation of a diffractive multifocal intraocular lens(IOL)in patients with contralateral monofocal IOL.METHODS:Twenty-two patients who already had implantation of a monofocal IOL in unilateral eye underwent implantation of a diffractive multifocal IOL in contralateral eye were enrolled.After 1,6,and 12 mo,uncorrected and distant corrected distant visual acuity(UCDVA and DCDVA),uncorrected and distant corrected intermediate-visual acuity(UCIVA and DCIVA),uncorrected and distant corrected near visual acuity(UCNVA and DCNVA),and contrast sensitivity were obtained.Halo/glare symptoms,spectacle dependence,and patient satisfaction were also evaluated.RESULTS:The mean age was 67.86±7.25 y and the average interval between two IOL implantations was 645.82±878.44 d.At 1 mo,binocular UCDVA was lower than 0.20 logMAR in 76%of patients(mean 0.12±0.13 logMAR),which increased to 90%by 6 and 12 mo.The binocular UCDVA was significantly better than the monocular results(P<0.05)at 1,6,and 12 mo.Additionally,UCNVA was lower than 0.40 logMAR in 82%of patients,increasing to 90%by 6 and 12 mo.Mean UCNVA in the multifocal IOL implanted eye was statistically significantly better than that in the monofocal IOL implanted eye(P<0.05)at 1,6,and 12 mo.About 5%of patients at 1 and 6 mo,reported"severe glare or halo".Patient satisfaction rates were 95%and 91%at 6 and 12 mo,respectively.CONCLUSION:Unilateral implantation of multifocal IOL in patients with a contralateral,monofocal IOL implantation results in high patient satisfaction rate,with low severe glare or halo rate during follow-up.It can represent a good option for patients who have previously had a monofocal IOL implantation regardless of two year interval duration between two IOL implantations.展开更多
基金Supported by the National Natural Science Foundation of China(No.82271100)the Jiangsu Science and Technology Support Program(No.BE2022805)the Clinical Skills Enhancement Program of Jiangsu Province Hospital(No.JSPH-MC-2022-24).
文摘AIM:To assess the visual electrophysiological outcomes in children with functional amblyopia who exhibited poor response to conventional treatment.METHODS:Twenty-one children with functional amblyopia,aged 5.7±2.1y(range:4-10y),underwent comprehensive ophthalmic and refractive evaluations.Spectral domain-optical coherence tomography(SD-OCT)and multifocal electroretinography(mfERG)were conducted to analyze the macular retinal thickness and the first-order response P1 ring of the mfERG in the amblyopic eye(AE)compared to the fellow good eye(GE).RESULTS:Initially,visual acuity in the AE ranged from 20/800 to 20/40,while the GE exhibited a range of 20/25 to 20/20(P<0.01).After 6mo of treatment,17 patients demonstrated improved visual acuity in the AE to 20/50 or better,while 4 children showed no improvement.SD-OCT revealed comparable macular and optic disc structures between the AE and GE.Prior to treatment,the mfERG P1 ring amplitude was significantly reduced in the AE compared to GE(P<0.05).The AE/GE ratio of P1 ring amplitude showed significant improvement post-treatment.However,a smaller AE/GE ratio before treatment was associated with poorer improvement post-treatment.CONCLUSION:In the management of functional amblyopia,a thorough assessment of amblyopic eye examinations is crucial.Approximately 20%of amblyopic eyes may not achieve significant improvement in visual acuity,despite the absence of detectable organic retinal abnormalities.mfERG may reveal underlying abnormalities.Integrating mfERG into initial assessments or treatment follow-ups can aid in identifying potential hidden retinal defects and predicting the prognosis of the amblyopic eye.
基金Supported by the Fuzhou Science and Technology Program(No.2023-S-005).
文摘AIM:To evaluate the influence of ocular biometric parameters on the performance of actual near-add power in the spectacle plane of multifocal intraocular lenses(MIOLs).METHODS:This retrospective study defined prediction error(PE)as the difference between actual postoperative near-add power and manufacturer-predicted values.Linear regression assessed PE correlations with axial length(AL),mean keratometry(K),pupil size,anterior chamber depth(ACD),lens thickness(LT),ACD+0.5×LT,and back-calculated IOL power.Differences in PE across MIOLs types,AL,K,pupil size,ACD,LT,ACD+0.5×LT,and back-calculated IOL power groups were compared.RESULTS:Totally 250 eyes of 250 patients(116 males and 134 females,mean age 56.22±12.31y)who underwent phacoemulsification with MIOL implantation were reviewed.PE showed no significant correlation with most parameters but had a weak positive correlation with LT.The mean predicted error(MPE)in the AL≤22,26–27,and 27–28 mm groups were 0.83(0.51,1.01)D,0.78(0.51,1.07)D,and 0.72(0.57,0.94)D respectively(P<0.001).The MPE in the K between the 45–46 D groups was 0.78(0.37,1.07)D(P=0.0004).The MPE in the LT between the 4.5–5.0 mm groups and≥5 mm was 0.72(0.50,1.01)D and 0.72(0.51,1.01)D respectively(P<0.001).The MPE in the back-calculated IOL power≥25 D was 0.86(0.60,1.01)D(P<0.001).CONCLUSION:Although there is no significant linear relationship between near-add power and most ocular biometry parameters,and specific segments of AL,K,LT,and IOL power have a significant impact on the near-add power of MIOLs.These factors should be taken into account in preoperative evaluations.
基金Supported by the National Natural Science Foundation of China(No.82171073No.82101147).
文摘●Multiple evanescent white dot syndrome(MEWDS)is a rare fundus disease,characterized by acute vision loss and visual field defects.Many previous studies have explained the possible pathogenesis and clinical features of primary MEWDS.However,as the number of reported cases increases,secondary MEWDS occurs in other related retinal diseases and injuries,exhibiting some special characteristics.The associated retinal diseases include multifocal choroiditis/punctate inner choroidopathy(MFC/PIC),acute zonal occult outer retinopathy,best vitelliform macular dystrophy,pseudoxanthoma elasticum,and ocular toxoplasmosis.The related retinal injury is laser photocoagulation,surgery,and trauma.Although primary MEWDS often have a self-limiting course,secondary MEWDS may require treatment in some cases,according to the severity of concomitant diseases and complications.Notably,MEWDS secondary to MFC/PIC that is prone to forming choroidal neovascularization and focal choroidal excavation,needs positive treatment with corticosteroids.The possible underlying pathogenesis of secondary MEWDS is the exposure of choroidal antigen after the disruption of Bruch’s membrane.The MEWDS-related features in secondary MEWDS are still evanescent under most circumstances.Its prognosis and treatment depend on the severity of complications.Current studies propose that the etiology is associated with immune factors,including viral infection,inflammation in choroid and Bruch’s membrane,and antigen exposure caused by retinal and/or choroidal insults.More pathogenic studies should be conducted in the future.Accurate diagnosis for secondary MEWDS could benefit patients in aspects of management and prognosis.
基金Supported by the Education Project of Yunnan Province,No.2023J767the High-level Talent Training Support Project of Yunnan Province,No.YNWR-MY-2020-053.
文摘BACKGROUND The incidence of multiple primary carcinomas(MPC)varies greatly,ranging from 0.73%to 11.70%in foreign countries,with duo-duplex carcinoma being the most common,trio-duplex carcinoma and above being rare,and simultaneous multigenic carcinoma being even rarer,accounting for 18.4%to 25.3%of the incidence of MPC.However,there is no report regarding patients presenting with simultaneous dual-origin carcinoma of the liver and colon and heterochronous pancreatic cancer.CASE SUMMARY We report a special case of multifocal carcinoma,in which one patient had a medical condition of primary liver and colon cancer and pancreatic cystadenocarcinoma 2 years after surgery.Through aggressive advanced fluorescent laparoscopic techniques,standardized immunotherapy,targeting,and chemotherapy,a better prognosis and a desirable survival period were achieved for the patient.CONCLUSION There is a need to clarify the nature of MPC through advanced surgical means to ensure better diagnosis and treatment.
文摘This case is a 49-year-old female patient who presented with suspected eustachian tube dysfunction symptoms that were refractory to medical treatment. She presented with conductive hearing loss and aural fullness on the left. A physical exam revealed an epitympanic fleshy mass in the middle ear with effusion. Imaging with MRI and CT showed opacification of the epitympanum with surrounding bony demineralization bilaterally left greater than right and significant thinning versus dehiscence of the tegmen mastoideum and tympani on the left with only thinning of the tegmen on the right. An MR temporal bone with and without contrast, demonstrated enhancement of the left middle ear extending to the tegmen and corresponding enhancement of the dura along the floor of the left middle cranial fossa as well as extending along foramen ovale into the infratemporal fossa. There was to a lesser degree similar appearance on the right. A biopsy of the middle ear mass on the left revealed meningioma. This case highlights the need to widen your differential with common symptoms when they are refractory to treatment.
文摘We present the case of a 29-year-old patient with a history of abdominal pain and vomiting.Based on wireless video capsule findings he was previously diagnosed with ileal Crohn's disease at a different institution,although the clinical and radiological picture was not typical and the response to corticosteroids was poor.We performed a single-balloon enteroscopy showing a short,ulcerous stenosis 50 cm proximal from Bauhin's valve.The endoscopic and clinical histopathological findings were compatible with cryptogenic multifocal ulcerous stenosing enteritis(CMUSE).High dose corticosteroids were again started,without effect.The monoclonal tumor necrosis factor-α(TNF-α) antibody infliximab was added to the medical therapy.After induction therapy,both clinical and endoscopic amelioration was obtained.Larger case studies are needed to confirm the efficacy of TNF-α inhibition in steroid refractory CMUSE.
文摘AIM: To investigate the independent factors associated with photic phenomena in patients implanted with refractive,rotationally asymmetric,multifocal intraocular lenses(MIOLs).METHODS: Thirty-four eyes of 34 patients who underwent unilateral cataract surgery,followed by implantation of rotationally asymmetric MIOLs were included.Distance and near visual acuity outcomes,intraocular aberrations,preferred reading distances,preoperative and postoperative refractive errors,mesopic and photopic pupil diameters,and the mesopic and photopic kappa angles were assessed.Patients were also administered a satisfaction survey.Photic phenomena were graded by questionnaire.Independent-related factors were identified by correlation and bivariate logistic regression analyses.RESULTS: The distance from the photopic to the mesopic pupil center(pupil center shift) was significantly associated with glare/halo symptoms [odds ratio(OR)=2.065,95% confidence interval(CI)=0.916-4.679,P=0.006] and night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007).The preoperative photopic angle kappa was significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041).The photopic angle kappa was also significantly associated with glare/halo symptoms(OR=2.155,95% CI=1.065-4.362,P=0.041) and with night vision problems(OR=1.832,95% CI=0.721-2.158,P=0.007) in patients implanted with rotationally asymmetric MIOLs.CONCLUSION: A large pupil center shift and misalignment between the visual and pupillary axis(angle kappa)may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs.
文摘Extraintestinal manifestations occur in about one-third of patients living with inflammatory bowel disease(IBD) and may precede the onset of gastrointestinal symptoms by many years. Neurologic disorders associated with IBD are not frequent, being reported in 3% of patients, but they often represent an important cause of morbidity and a relevant diagnostic issue. In addition, the increasing use of immunosuppressant and biological therapies for IBD may also play a pivotal role in the development of neurological disorders of different type and pathogenesis. Hence, we provide a complete and profound review of the main features of neurological complications associated with IBD, with particular reference to those related to drugs and with a specific focus on their clinical presentation and possible pathophysiological mechanisms.
基金Hongtao Wang acknowledges the support from National Key Research and Development Program of China(2017YFB0403602)China Scholarship Council.Baohua Jia acknowledges the support from the Australian Research Council through the Discovery Projects(DP150102972,DP190103186)+5 种基金the Industrial Transformation Training Centres scheme(Grant No.IC180100005)support from Defence Science Institute(DSI)and Defence Science and Technology Group(DSTG).C.W.Q.acknowledges the support from the National Research Foundation,Prime Minister’s Office,Singapore,under its Competitive Research Programme(CRP award NRF CRP22-2019-0006)Advanced Research and Technology Innovation Centre(ARTIC)under the grant(R-261-518-004-720)A STAR under Advanced Manufacturing and Engineering(AME)Individual Research Grant(IRG A2083c0060)Tian Lan acknowledges National Key Basic Research Program 973 Project(2013CB329202)National Major Scientific Instruments and Equipments Development Project supported by National Natural Science Foundation of China(No.61827814).
文摘Ultrathin flat metalenses have emerged as promising alternatives to conventional diffractive lenses,offering new possibilities for myriads of miniaturization and interfacial applications.Graphene-based materials can achieve both phase and amplitude modulations simultaneously at a single position due to the modification of the complex refractive index and thickness by laser conversion from graphene oxide into graphene like materials.In this work,we develop graphene oxide metalenses to precisely control phase and amplitude modulations and to achieve a holistic and systematic lens design based on a graphene-based material system.We experimentally validate our strategies via demonstrations of two graphene oxide metalenses:one with an ultra-long(~16λ)optical needle,and the other with axial multifocal spots,at the wavelength of 632.8 nm with a 200 nm thin film.Our proposed graphene oxide metalenses unfold unprecedented opportunities for accurately designing graphene-based ultrathin integratable devices for broad applications.
文摘AIM: To compare the clinical outcomes of a variety of multifocal intraocular lenses(MIOLs) in patients diagnosed with presbyopia or cataracts. METHODS: This clinical trial study included 141 patients(282 eyes) with different MIOLs implantation. The Symfony(60 eyes), the Re STOR(100 eyes), the AT LISAtri(60 eyes), and the Pan Optix(62 eyes) intraocular lenses were evaluated in this prospective interventional study. The near, intermediate, and distant visual acuities, contrast sensitivity, and defocus curve were measured as valid criteria. To statistically analyze the results, we used the Statistical Package for Social Science software, the non-parametric Wilcoxon signed-rank t, the one-way analysis of variance and the Tukey’s post-hoc test in our analysis. Moreover, we conducted a detailed literature search on the Pub Med database in English about MIOLs, in total 59 studies were included in this review article.RESULTS: The four approaches did not show any significant difference in the best-corrected distance visual acuity(P>0.05). The defocus curves at the contrast of 100% showed that trifocal IOLs had better intermediate performance than the bifocal IOL(P<0.05). There were no statistically significant differences between AT LISAtri and Pan Optix lenses for visual acuity at all distances. The eyes with Pan Optix, Symfony, and AT LISAtri IOL showed better contrast sensitivity than those Re STOR at spatial frequencies of 1, 3, and 6 cpd in photopic and mesopic conditions(P<0.001). CONCLUSION: All four groups of the multifocal lenses were satisfying in terms of distance and near vision. Also, the group of trifocal lenses led to satisfactory outcomes in intermediate vision, without degradation in quality of vision.
基金Zhejiang Key Innovation Team Project(No. 2009R50039)Doctoral Fund of Ministry of Education of China (No: 20100101120135)Key Lab Fund of Zhejiang Province, China (No. 2011E10006)
文摘·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ·METHODS: Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular and binocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) for distance, intermediate and near, spherical aberration (SA), contrast and glare sensitivity, near point refractive power, uncorrected and best corrected near stereoscopic acuity (NSA). Patient satisfaction was assessed by a questionnaire. ·RESULTS:Threemonthspostoperatively,themonocular and binocular UCVA and DCVA at near of Tecnis ZMA00 were significantly better than other two groups. The mean SA for 5.0mm optical zone in Tecnis ZMA00 and Tecnis ZA9003 was significantly lower than that in Akreos Adapt. Mean contrast sensitivity and glare sensitivity were better for Tecnis ZA9003 group than for other two groups. Patients with Tecnis ZMA00 had higher monocular and binocular near point refractive power and uncorrected NSA than monofocal groups. The patients in Tecnis ZMA00 had higher mean values for halo compared with other two groups. ·CONCLUSION: Tecnis ZMA00 provided better near VA and uncorrected NSA and higher near point refractive power than monofocal IOLs and patients were spectacle independent. The IOLs with Tecnis aspheric design improved contrast and glare sensitivity. Patients with Tecnis ZMA00 reported more disturbances on visual phenomena of halo. ·
文摘We describe common and less common diseases that can cause magnetic resonance signal abnormalities of middle cerebellar peduncles(MCP), offering a systematicapproach correlating imaging findings with clinical clues and pathologic mechanisms. Myelin abnormalities, different types of edema or neurodegenerative processes, can cause areas of abnormal T2 signal, variable enhancement, and patterns of diffusivity of MCP. Pathologies such as demyelinating disorders or certain neurodegenerative entities(e.g., multiple system atrophy or fragile X-associated tremor-ataxia syndrome) appear to have predilection for MCP. Careful evaluation of concomitant imaging findings in the brain or brainstem; and focused correlation with key clinical findings such as immunosuppression for progressive multifocal leukoencephalopahty; hypertension, post-transplant status or high dose chemotherapy for posterior reversible encephalopathy; electrolyte disorders for myelinolysis or suspected toxic-drug related encephalopathy; would yield an appropriate and accurate differential diagnosis in the majority of cases.
文摘To investigate the characteristic radiologic findings of cryptogenic multifocal ulcerous stenosing enteritis (CMUSE) which can be differentiated from other similar bowel disease and to assess their clinical behavior. METHODSTwenty pathologically and clinically confirmed CMUSE patients (males:females = 8:12; mean age: 40.4 years) between March 2002 and August 2015 from seven academic centers in South Korea were retrospectively reviewed. We evaluated small bowel series (SBS; n = 25), computed tomography (CT) enterography (n = 21), magnetic resonance (MR) enterography (n = 2), and abdominopelvic CT (n = 18) images, focusing on enteric and perienteric manifestations. Any change in radiologic features during follow-up period was recorded. We evaluated clinical data including presenting symptoms, laboratory finding and presence of relapse from electronic medical records. Histopathologic findings were also evaluated. RESULTSThe main symptoms were abdominal pain (n = 12) and anemia (n = 10). All patients showed small bowel strictures (n = 52, mean: 2.6 per patient) on initial CT/MR, located in the ileum (n = 47) or jejunum (n = 5). Strictures showed short-length (mean: 10.44 mm) and circumferential bowel wall thickening (mean: 5.56 mm) with layered enhancement (n = 48) that were also noted on initial SBS (n = 36) with shallow ulcers (n = 10). Some ulcerative lesions or wall thickening progressed into strictures on follow-up SBS/CT, and some strictures revealed recurrent ulceration on follow-up SBS. There were no penetrating disease features like fistula or abscess and no gastrointestinal tract involvement except the small bowel. Nine patients experienced disease recurrence (median relapse-free period: 32 mo) even post-operatively. Histopathologic features of surgically resected specimens were characterized as multiple superficial ulcerations confined to mucosa or submucosa and multiple strictures. CONCLUSIONUnder characteristic radiologic findings with multiple short-segmental strictures and/or shallow ulcers of the small intestine, CMUSE should be considered when assessing patients with recurrent abdominal pain and anemia.
基金Coco-Martin MB,Maldonado-López MJ,Molina-Martín A and Pi?ero DP are supported by CDTI(Centro para el Desarrollo Tecnológico Industrial,Ministry of Economy and Competitiveness of Spain)by means of the program PID(“Proyectos de Investigación y Desarrollo”)The author Pi?ero DP has been also supported by the Ministry of Economy,Industry and Competitiveness of Spain within the program Ramón y Cajal(RYC-2016-20471)Valenzuela PL is supported by a contract granted by University of Alcalá(FPI2016)
文摘Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they are associated with a higher prevalence of dysphotopsia symptoms that is one of the most common causes of patient dissatisfaction. Neuroadaptation seems to play a major role in the optimal adaptation to multifocal IOLs. In this context, the development of strategies that facilitate the neuroadaptation process to multifocality might be an effective strategy to reduce patients' dissatisfaction. Video games have been proved to be effective for the improvement of visual acuity and for the promotion of neuroplasticity in elderly subjects and other populations with cortical-related visual impairment. This narrative review highlights the physiological potential of video games as a perceptual strategy to improve visual acuity and promote neuroplasticity in patients using multifocalIOLs, although research is still needed to confirm these benefits in this specific population, with only one comparative study to this date providing evidence of them.
文摘AIM: To evaluate the effect of prophylactic administration of nepafenac in prevention of macular edema occurring in diabetic patients after phacoemulsification and to investigate the correlation between optical coherence tomography(OCT) foveal thickness and multifocal electroretinogram(MF-ERG) parameters.METHODS: The study included two groups. Group 1 included 50 diabetic patients with senile cataract(50 eyes, 30 females, 20 males, aged 55±7 y) received nepafenac 0.1% eye drop. Group 2 included another 50 diabetic patients with senile cataract(50 eyes, 22 female, 28 males, aged 53.8±8 y) did not receive nepafenac. All patients were followed up for 3 mo postoperatively. OCT and MF-ERG were done preoperative and at 1 wk, 1, 2 and 3 mo.RESULTS: The mean foveal thickness was statistically significantly lower in Group 1. Five eyes in Group 2 developed clinical cystoid macular oedema(CMO)(10%), and no patients in Group 1 developed central macular thickening more than 50 μm. There were insignificant differences in MF-ERG amplitudes and latencies between the two groups except in the five eyes that developed CMO, there statistically significant reduction of MF-ERG amplitude with increase in foveal thickness. CONCLUSION: Perioperative nepafenac reduces the incidence of CMO following uncomplicated phacoemulsification significantly. Nepafenac has no side effects.
基金Supported by National Key Research and Development Program of China(No.2017YFC1104600)National Natural Science Foundation of China(No.81770909)。
文摘AIM:To evaluate the accuracy of eight different intraocular lens(IOL)power calculation formulas for a segmented multifocal IOL.METHODS:A total of 53 eyes of 41 adult cataract patients who underwent phacoemulsification and implantation with the SBL-3 segmented multifocal IOL between January 1,2017 and January 31,2019 were included in this retrospective study.Preoperative biometry measurements were obtained using an IOL Master.Manifest refraction was performed at least 4 wk postoperatively.Accuracy of the eight formulas[Barrett Universal II,Emmetropia Verifying Optical(EVO),Haigis,Hill-RBF 2.0,Hoffer Q,Holladay 1,Kane,and SRK/T]was analyzed.RESULTS:Using current lens constants,all formulas exhibited errors of slight myopic shift in refractive prediction.The Barrett Universal II formula had a significantly lower median absolute error(MedAE)than did Holladay 1(P=0.02),Kane(P=0.001)and Hill-RBF 2.0(P<0.001)formulas.The Haigis formula had a lower MedAE value than did the Hill-RBF 2.0 formula(P=0.005).Differences in MedAE values among SRK/T,EVO and Hoffer Q formulas were not significant.After optimizing lens constants,the MedAE values of all formulas were reduced;significant changes were noted for EVO(P=0.022),Haigis(P=0.048);Hill-RBF 2.0(P=0.014),Holladay 1(P=0.045)and Kane(P=0.022)formulas.All formulas performed equally well after optimization of lens constants(P=0.203).CONCLUSION:All eight formulas tend to result in a myopic shift when using current lens constants.Optimized lens constants improve the accuracy of these formulas among adult Chinese patients.
文摘AIM: To compare visual quality in cataract patients with low corneal astigmatism who underwent intraocular lens(IOL) implantation, and evaluate effects of low levels of astigmatism on visual outcomes in multifocal pseudophakic eyes.METHODS: This retrospective review of clinical records comprised patients with preoperative regular corneal astigmatism of 0.75-1.0 diopters(D) with-the-rule or 0.5-0.75 D against-the-rule who had uneventful cataract surgery and AcrySof IQ ReSTOR Toric-2 IOL(ART2) or AcrySof IQ ReSTOR IOL(ReSTOR) implantation. Retrospective data collection included postoperative ART2 axis rotation, uncorrected astigmatism, uncorrected entire visual acuities, distance corrected entire visual acuities, average modulation transfer function(aMTF), Strehl ratio(SR), spectacle independence, and patient satisfaction between groups.RESULTS: Mean ART2 axis rotation was 3.12°±0.70°. No secondary surgery was required to realign IOL axis. Residual astigmatism values were-0.18±0.07 D and-0.91±0.25 D in groups ART2 and ReSTOR(P<0.05). Three months postoperatively, the mean uncorrected distant, intermediate, and near visual acuities of group A were 0.01±0.05, 0.05±0.07, 0.02±0.07 logMAR, respectively; these were better than those of group R, which were 0.08±0.06, 0.15±0.12, and 0.09±0.08 logMAR, respectively(P<0.05). aMTF, SR, and spectacle independence rates were not significantly different. All patients were satisfied with postoperative results.CONCLUSION: ART2 is more suitable than ReSTOR for cataract patients with regular corneal astigmatism 0.75-1.0 D with-the-rule or 0.5-0.75 D against-the-rule.
基金Supported by the Student Research Grant of University of Ulsan College of Medicine,Seoul,Korea(No.17-18)Grant from the Asan Institute for Life Sciences,Seoul,Korea(No.2014-464)。
文摘AIM:To evaluate clinical outcomes of unilateral implantation of a diffractive multifocal intraocular lens(IOL)in patients with contralateral monofocal IOL.METHODS:Twenty-two patients who already had implantation of a monofocal IOL in unilateral eye underwent implantation of a diffractive multifocal IOL in contralateral eye were enrolled.After 1,6,and 12 mo,uncorrected and distant corrected distant visual acuity(UCDVA and DCDVA),uncorrected and distant corrected intermediate-visual acuity(UCIVA and DCIVA),uncorrected and distant corrected near visual acuity(UCNVA and DCNVA),and contrast sensitivity were obtained.Halo/glare symptoms,spectacle dependence,and patient satisfaction were also evaluated.RESULTS:The mean age was 67.86±7.25 y and the average interval between two IOL implantations was 645.82±878.44 d.At 1 mo,binocular UCDVA was lower than 0.20 logMAR in 76%of patients(mean 0.12±0.13 logMAR),which increased to 90%by 6 and 12 mo.The binocular UCDVA was significantly better than the monocular results(P<0.05)at 1,6,and 12 mo.Additionally,UCNVA was lower than 0.40 logMAR in 82%of patients,increasing to 90%by 6 and 12 mo.Mean UCNVA in the multifocal IOL implanted eye was statistically significantly better than that in the monofocal IOL implanted eye(P<0.05)at 1,6,and 12 mo.About 5%of patients at 1 and 6 mo,reported"severe glare or halo".Patient satisfaction rates were 95%and 91%at 6 and 12 mo,respectively.CONCLUSION:Unilateral implantation of multifocal IOL in patients with a contralateral,monofocal IOL implantation results in high patient satisfaction rate,with low severe glare or halo rate during follow-up.It can represent a good option for patients who have previously had a monofocal IOL implantation regardless of two year interval duration between two IOL implantations.