期刊文献+
共找到160,150篇文章
< 1 2 250 >
每页显示 20 50 100
Establishing models of portal vein occlusion and evaluating value of multi-slice CT in hepatic VX2 tumor in rabbits
1
作者 Yue-Yong Qi Li-Guang Zou +1 位作者 Ping Liang Dong Zhang 《World Journal of Gastroenterology》 SCIE CAS CSCD 2007年第24期3333-3341,共9页
AIM: To establish models of portal vein occlusion of hepatic VX2 tumor in rabbits and to evaluate the value of multi-slice CT. METHODS: Forty New Zealand rabbits were divided into 4 groups according to digital table... AIM: To establish models of portal vein occlusion of hepatic VX2 tumor in rabbits and to evaluate the value of multi-slice CT. METHODS: Forty New Zealand rabbits were divided into 4 groups according to digital table: Immediate group (group A; transplantation of tumor immediately after the portal vein occlusion), 3-wk group (group B; transplantation of tumor at 3 wk after the portal vein occlusion), negative control group (group C) and positive control group (group D), 10 rabbits in each group. Hepatic VX2 tumor was transplanted with abdominalembedding innoculation immediately after the portal vein occlusion and at 3 wk after the portal vein occlusion. Meanwhile, they were divided into negative control group (Left external branch of portal vein was occluded by sham-operation, and left exite was embedded and inoculated pseudoly) and positive control group (Transplanted tumor did not suffer from the portal vein occlusion). All rabbits were scanned with multi-slice CT. RESULTS: All 40 animals were employed in the final analysis without death. Tumor did not grow in both immediate group and 3-wk group. In 3-wk group, left endite was atrophied and growth of tumor was inhibited. The maximal diameter of tumor was significantly smaller than that in positive control group (2.55±0.46 vs 3.59±0.37 cm, t = 5.57, P 〈 0.001). Incidences of metastasis in the liver and lung were lower in 3-wk group than those in positive control group (10% vs 400, and 90% vs 100%, respectively). The expression intensities of the vascular endothelium growth factor (VEGF) in groups A, B, C and D were 0.10±0.06, 0.66±0.21, 0.28±0.09 and 1.48±0.32, respectively. VEGF expression level in the test group A was significantly lower than that in the negative control group C (t = 5.07; P 〈 0.001).In addition, VEGF expression in the test group B was significantly lower than that in the positive control group D (t = 6.38; P 〈 0.001). Scanning with multi-slice CT showed that displaying rate of hepatic artery branches was obviously lower in grade Ⅲ(40%) than that in grade Ⅰ(70%) and Ⅱ(100%) (P 〈 0.05); but there was no significant difference in displaying rate of the portal vein at various grades. Values of blood flow (BF) of the liver, blood volume (BV), mean transit time (MTT) and permeability of vascular surface (PS) were lower in the immediate group and 3-wk group than those in control groups, but values of hepatic arterial fraction (HAF) were increased. Significant positive correlations were existed between BF and BV (r = 0.905, P 〈 0.01), and between BF and PS (r = 0.967, P 〈 0.01), between BV and PS (r = 0.889, P 〈 0.01). A significant negative correlation existed between PV and HAF (r = -0.768, P 〈 0.01), between PS and HAF (r = -0.557, P 〈 0.01). The values of BF, BV and PS had a positive correlation with VEGF (rBF = 0.842, rBV = 0.579, rPS = 0.811, P 〈 0.01) . However, there was no significant correlation between the values of MTT and HAF and the VEGF expression (rMTt = 0.066, rHAF = -0.027). CONCLUSION: Ligating the left external branch of portal vein is an ideal way to establish models of portal vein occlusion in rabbits with hepatic VX2 tumor. Multi slice CT plays a key role in evaluating effect of portal vein occlusion. 展开更多
关键词 Portal vein multi-slice ct X-ray computer VX2 tumor Portal vein occlusion model
暂未订购
Validation of a novel imaging approach using multi-slice CT and cone-beam CT to follow-up on condylar remodeling after bimaxillary surgery 被引量:7
2
作者 laura ferreira pinheiro nicolielo jeroen van dessel +5 位作者 eman shaheen carolina letelier marina codari constantinus politis ivo lambrichts reinhilde jacobs 《International Journal of Oral Science》 SCIE CAS CSCD 2017年第3期139-144,共6页
The main goal of this study was to introduce a novel three-dimensional procedure to objectively quantify both inner and outer condylar remodelling on preoperative multi-slice computed tomography (MSCT) and postopera... The main goal of this study was to introduce a novel three-dimensional procedure to objectively quantify both inner and outer condylar remodelling on preoperative multi-slice computed tomography (MSCT) and postoperative cone-beam computed tomography (CBCT) images. Second, the reliability and accuracy of this condylar volume quantification method was assessed. The mandibles of 20 patients (11 female and 9 male) who underwent bimaxillary surgery were semi-automatically extracted from MSCT/CBCT scans and rendered in 3D. The resulting condyles were spatially matched by using an anatomical landmark-based registration procedure. A standardized sphere was created around each condyle, and the condylar bone volume within this selected region of interest was automatically calculated. To investigate the reproducibility of the method, inter- and intra-observer reliability was calculated for assessments made by two experienced radiologists twice five months apart in a set of ten randomly selected patients. To test the accuracy of the bone segmentation, the inner and outer bone structures of one dry mandible, scanned according to the clinical set-up, were compared with the gold standard, micro-CT. Thirty-eight condyles showed a significant (P〈O.05) mean bone volume decrease of 26.4%_ 11.4% (502.9 mm3+ 268.1 mm3). No significant effects of side, sex or age were found. Good to excellent (ICC〉 0.6) intra- and inter-observer reliability was observed for both MSCT and CBCT. Moreover, the bone segmentation accuracy was less than one voxel (0.4 mm) for MSCT (0.3 mm __. 0.2 mm) and CBCT (0.4 mm _ 0.3 mm), thus indicating the clinical potential of this method for objective follow-up in pathological condylar resorption. 展开更多
关键词 condylar resorption Cone-beam computed tomography mandibular condyle multi-slice computed tomography three-dimensional imaging
暂未订购
Study on the Application and Value of Multi-slice Spiral CT in Acute Appendicitis
3
作者 Zheng Zhang 《Journal of Clinical and Nursing Research》 2025年第5期325-331,共7页
Objective:To investigate the diagnostic value of multi-slice spiral CT(MSCT)for patients with acute appendicitis(AA).Methods:Fifty patients with suspected AA who visited the hospital from January 2023 to January 2025 ... Objective:To investigate the diagnostic value of multi-slice spiral CT(MSCT)for patients with acute appendicitis(AA).Methods:Fifty patients with suspected AA who visited the hospital from January 2023 to January 2025 were selected as samples.All patients underwent MSCT and ultrasound diagnosis,and the diagnostic efficacy of MSCT was analyzed in comparison with pathology.Results:Pathology indicated 40 positive and 10 negative cases,ultrasound indicated 30 positive and 20 negative cases,and MSCT indicated 39 positive and 11 negative cases.The diagnostic efficacy of MSCT was higher than that of ultrasound(P<0.05).The accuracy of pathological classification of MSCT was higher than that of ultrasound(P<0.05).The detection rate of MSCT imaging indicators in AA patients was higher than that in non-AA patients(P<0.05).Conclusion:MSCT has high diagnostic efficacy in AA patients and can assist physicians in determining pathological classification. 展开更多
关键词 Acute appendicitis multi-slice spiral ct Diagnostic efficacy
暂未订购
Multi-slice Spiral CT Three-dimensional Portography in Portal Vein Tumor Thrombus of Hepatic Cancer
4
作者 俞同福 王德杭 +1 位作者 冯阳 张廉良 《The Chinese-German Journal of Clinical Oncology》 CAS 2003年第4期203-205,250,共4页
Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collect... Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collected, of which 6 cases were normal, 5 cases were subjected to cirrhosis and hypertension of portal vein, 42 cases had portal tumor thrombus of hepatic cancer, and the remaining 4 cases showed lymph node enlargment in hilar of liver. All data of the patients came from conventional multi-slice spiral CT double phase of liver. Contrast media was 1.5–2 ml/kg with the injection rate being 2.5–3 ml/s. Axis and 3D portography was analyzed and compared in 42 cases of portal tumor thrombus of hepatic cancer.Results: According to portal tumor thrombus position, 42 cases were fallen into three categories: left (13 cases), right (20 cases), main (9 cases) of potal vein. There was no difference between axis and 3D portography in displaying portal tumor thrombus of hepatic cancer (P>0.05), but 3D portography showing collateral branches was better than axis portography after main portal vein thrombus.Conclusion: Multi-slice spiral CT 3D portography can display the position and types of portal tumor thrombus of hepatic cancer. 3D combined with axis portography can better evaluate the portal tumor thrombus of hepatic cancer and guide to select the therapies. Key words portal vein - tumor thrombus - multi-slice CT - 3 dimension imaging 展开更多
关键词 portal vein tumor thrombus multi-slice ct 3 dimension imaging
暂未订购
Three-dimensional Imaging of Multi-slice Spiral CT in Bronchial Artery Correlative Study on Blood Supply of Central Lung Cancer and Its Clinical Significance 被引量:4
5
作者 李智勇 杨冬 +2 位作者 伍建林 黎庶 董天 《The Chinese-German Journal of Clinical Oncology》 CAS 2005年第1期40-42,67,共4页
Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention t... Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer. 展开更多
关键词 bronchial artery multi-slice spiral ct three-dimensional reconstruction ANGIOGRAPHY
暂未订购
A preliminary study on correlations of triple-phase multi-slice CT scan with histological differentiation and intratumoral microvascular/lymphatic invasion in gastric cancer 被引量:6
6
作者 YIN Xin-dao HUANG Wen-bin +3 位作者 L(U) Cheng-yu ZHANG Lin WANG Li-wei XIE Guang-hui 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第3期347-351,共5页
Background Many studies have shown that cancer cell differentiation and microvascular invasion play a principle role in cancer progression and metastasis, and non-invasive imaging techniques such as CT, MRI and US ass... Background Many studies have shown that cancer cell differentiation and microvascular invasion play a principle role in cancer progression and metastasis, and non-invasive imaging techniques such as CT, MRI and US assessing the differentiation and the surgical resectibility and the prognosis of cancers are now of great importance. This study aimed to explore the correlation of triple-phase multi-slice CT scan with the histological differentiation and intratumor microvascular/lymphatic invasion of progressive gastric cancer.Methods The present study included 64 patients with gastric cancer, all of whom underwent routinal and dual-phase contrast enhancement multi-slice CT examinations of the upper abdomen before surgery. The post-operative specimens were used for determination of histological differentiation, cancer cell invasion of intratumoral microvascular/lyrnphatic vessel identified by CD34 and D2-40 expression. Correlations between contrast enhancement ratio (CER) of triple-phase multi-slice CT scan in gastric cancer and histological differentiation as well as intraturnoral microvascular/lymphatic invasion were compared and analyzed.Results There was a significant correlation between CER of triple-phase CT scan in gastric cancer and tumor histological differentiation (P〈0.05). CER of the arterial phase in gastric cancer with intratumoral microvascular invasion was significantly higher than that without invasion (0.61±0.28 vs. 0.46±0.14, P 〈0.05); CER of the arterial-parenchymal phase was significantly lower in gastric cancer with intratumoral microvascular invasion than that without invasion (1.81±0.39 vs. 2.28±0.80, P〈0.05). However, CER of the parenchymal phase in gastric cancer with intratumoral lymphatic invasion was significantly higher than that without invasion (1.25±0.57 vs. 1.00±0.35, P〈0.05).Conclusions CER of triple-phase multi-slice CT scan in gastric cancer is closely correlated with intratumoral microvascular and lymphatic invasion, and also could be used as a marker for histological differentiation. 展开更多
关键词 gastric cancer multi-slice ct histological differentiation vascular invasion
原文传递
Multi-slice CT contrast-enhanced presentations of advanced gastric cancer: associations with histo-differentiation and expression of p53 and P-glycoprotein 被引量:4
7
作者 YIN Xin-dao ZHAO Jian-hua +7 位作者 ZHANG Lin WANG Li-ping LU Ling-quan WANG Li-wei XIE Guang-hui WU Qian-zhi WANG Shu-zhi GU Jian-ping 《Chinese Medical Journal》 SCIE CAS CSCD 2008年第24期2487-2491,共5页
Background This study aimed to investigate multi-slice CT contrast-enhanced presentation of gastric cancer and its correlation with histo-differentiation and p53 and P-glycoprotein (P-gp) expression. Methods Sixty-s... Background This study aimed to investigate multi-slice CT contrast-enhanced presentation of gastric cancer and its correlation with histo-differentiation and p53 and P-glycoprotein (P-gp) expression. Methods Sixty-six patients with gastric cancer in the present study underwent a multi-slice CT preoperative routine and dual-phase contrast-enhanced examination of the upper abdomen; postoperative specimens were used to determine histo-differentiation and the expression of p53 and P-gp. The correlation of multi-slice CT contrast-enhanced presentation with histo-differentiation and expression of p53 and P-gp was analyzed. Results The dual-phase contrast-enhanced ratio (CER) was not correlated with the histo-differentiation of gastric cancer (P 〉0.05). Positive expression of p53 and P-gp was significantly higher in the cases of layered or heterogeneous enhancement than in the cases of homogenous enhancement (P 〈0.05). Positive expression of p53 was also correlated with the arterial phase CER, tumor size and lymph node metastasis (P 〈0.05), but not with infiltration thickness of the gastric wall, nor was it correlated with the portal phase CER (P 〉0.05). Positive expression of P-gp was only correlated with the portal phase CER (P=0.005). Conclusions Differently enhanced pattern and CER of the arterial and portal phase in gastric cancer correlate with its different histo-differentiation and expression of p53 and P-gp respectively. In addition, tumor size and lymph node metastasis of gastric cancer relate to the expression of p53. 展开更多
关键词 gastric cancer multi-slice ct P53 P-GP
原文传递
Evaluation of spinal cord vessels using multi-slice CT angiography 被引量:1
8
作者 陈爽 钱建国 冯晓源 《Chinese Medical Journal》 SCIE CAS CSCD 2004年第12期1862-1864,共3页
关键词 spinal cord vascular diseases · multi-slice ct angiography · spinal angiography
原文传递
Wave-MambaCT:基于小波Mamba的低剂量CT伪影抑制方法
9
作者 崔学英 王宇航 +2 位作者 刘斌 上官宏 张雄 《电子与信息学报》 北大核心 2026年第3期982-993,共12页
低剂量CT(LDCT)图像中的伪影和噪声影响疾病的早期诊断和治疗。基于卷积神经网络的去噪方法在远程建模方面能力有限。与Transformer架构的远程建模方法相比,基于Mamba模型在建模时计算复杂度低,然而现有的Mamba模型存在信息丢失或噪声... 低剂量CT(LDCT)图像中的伪影和噪声影响疾病的早期诊断和治疗。基于卷积神经网络的去噪方法在远程建模方面能力有限。与Transformer架构的远程建模方法相比,基于Mamba模型在建模时计算复杂度低,然而现有的Mamba模型存在信息丢失或噪声残留的缺点。为此,该文提出一种基于小波Mamba的去噪模型WaveMambaCT。首先利用小波变换的多尺度分解解耦噪声和低频内容信息。其次,构建残差模块结合状态空间模型的Mamba模块提取高低频带的局部和全局信息,并用无噪的低频特征通过基于注意力的跨频Mamba模块校正并增强同尺度的高频特征,在去除噪声的同时保持更多细节。最后,分阶段采用逆小波变换渐进恢复图像,并设置相应的损失函数提高网络的稳定性。实验结果表明Wave-MambaCT在较低的计算复杂度和参数量下,不仅提高了低剂量CT图像的视觉效果,而且在PSNR,SSIM,VIF和MSE 4种定量指标上均优于现有的去噪方法。 展开更多
关键词 低剂量ct 伪影抑制 小波变换 Mamba
在线阅读 下载PDF
低剂量MSCT与X线在新生儿呼吸窘迫综合征诊断中的应用研究
10
作者 张靖 任亚方 +2 位作者 王品 齐玉敏 冯园 《中国CT和MRI杂志》 2026年第1期42-44,共3页
目的探究低剂量多层螺旋CT(MSCT)与X线在新生儿呼吸窘迫综合征(NRDS)诊断中的应用价值。方法收集2019年1月至2024年2月我院收治的100例NRDS的病例资料,均接受MSCT及X线检查,观察其MSCT及X线特点,评估其两者对NRDS的诊断效能。结果(1)100... 目的探究低剂量多层螺旋CT(MSCT)与X线在新生儿呼吸窘迫综合征(NRDS)诊断中的应用价值。方法收集2019年1月至2024年2月我院收治的100例NRDS的病例资料,均接受MSCT及X线检查,观察其MSCT及X线特点,评估其两者对NRDS的诊断效能。结果(1)100例NRDS患儿的MSCT图像中图像质量优42例(42.00%),图像质量良37例(37.00%),图像质量合格20例(20.00%),1例患儿图像质量不合格,图像质量合格率为99.00%,经镇静后重新检查,合格率为100%。100例NRDS患儿中,35例(35.00%)患儿MSCT示双肺野呈大片状,且形状不对称,边缘模糊,形成浸润影,双肺背部肺组织改变更明显;20例(20.00%)患儿MSCT示双肺纹理增多,且纹理模糊,沿肺纹理可见斑点状影或模糊小斑片状影;30例(30.00%)患儿MSCT示双肺呈低透亮度,可见磨玻璃样;15例(15.00%)患儿MSCT示双肺野密度均升高,且呈白肺,其中10例(10.00%)患儿呈现肺组织受压,纵隔移位至健侧表现。(2)100例NRDS患儿中,58例(58.00%)患儿X线示双肺可见广泛细颗粒网状影,心影、横隔均清晰可见,且伴有支气管充气征;42例(42.00%)患儿X线示双肺野一致性密度升高,见“白肺”及明显支气管充气征,心影、横隔边缘难以分辨;(3)以临床诊断为金标准,MSCT诊断NRDS的准确率为91.00%,敏感度为94.31%,特异性为66.67%;X线诊断N R D S的准确率为80.00%,敏感度为85.22%,特异性为41.67%;MSCT+X线对NRDS的诊断效能最高,诊断准确率为97.00%,敏感度为97.73%,特异性为91.67%。结论低剂量MSCT及X线对NRDS均具备良好的诊断价值,且MSCT相较X线诊断效能更高,但两者联合诊断可进一步提高诊断效能。 展开更多
关键词 低剂量多层螺旋ct X线 新生儿呼吸窘迫综合征 应用效果
暂未订购
多排螺旋CT增强扫描评估胃癌脉管浸润及预后的价值
11
作者 刘娜 李兴华 +2 位作者 胡伟 胡丹妮 曹阳阳 《中国CT和MRI杂志》 2026年第2期141-143,共3页
目的探究多排螺旋CT增强扫描评估胃癌脉管浸润(LVI)及预后的价值。方法回顾性分析2022年1月至2023年6月于我院就诊的80例胃癌患者临床资料,患者均接受病理诊断和多排螺旋CT增强扫描检查,评估多排螺旋CT增强扫描对LVI的诊断效能。收集患... 目的探究多排螺旋CT增强扫描评估胃癌脉管浸润(LVI)及预后的价值。方法回顾性分析2022年1月至2023年6月于我院就诊的80例胃癌患者临床资料,患者均接受病理诊断和多排螺旋CT增强扫描检查,评估多排螺旋CT增强扫描对LVI的诊断效能。收集患者临床资料,根据是否发生LVI将患者分为LVI组和非LVI组,比较两组患者病理特征,采用多因素Logistic回归分析胃癌患者发生LVI的影响因素,随访1年,采用Kaplan-Meier分析多排螺旋CT增强扫描对胃癌LVI预后的影响。结果以手术病理检查为金标准,多排螺旋CT增强扫描诊断LVI的kappa值为0.796,多因素Logistic回归分析显示,淋巴结转移、血管进入征及静脉标准化CT值是胃癌患者发生LVI独立危险因素(P均<0.05);Kaplan-Meier分析显示,非LVI患者的无病生存期显著高于LVI患者(P均<0.05)。结论多排螺旋CT增强扫描评对胃癌LVI具有较好的评估价值,且可评估胃癌LVI预后。 展开更多
关键词 胃癌 脉管浸润 多排螺旋ct增强扫描 病理特征 预后
暂未订购
基于CT扫描技术的透水混凝土孔隙特性研究
12
作者 徐丽娜 魏超 +2 位作者 丁旭 黄占芳 刘宁 《水电能源科学》 北大核心 2026年第1期114-118,共5页
为深入研究聚丙烯仿钢纤维透水混凝土的微观机理,采用CT扫描技术对试件进行扫描,通过三维数字重构技术建立了孔隙结构的可视化模型。基于图像分析方法对比研究了纤维改性前后材料内部孔隙系统的形态演变特征。结果表明,聚丙烯仿钢纤维... 为深入研究聚丙烯仿钢纤维透水混凝土的微观机理,采用CT扫描技术对试件进行扫描,通过三维数字重构技术建立了孔隙结构的可视化模型。基于图像分析方法对比研究了纤维改性前后材料内部孔隙系统的形态演变特征。结果表明,聚丙烯仿钢纤维的加入可有效提高试件的强度,但会抑制试块的透水性能,试块各层面孔隙率稳定在15%~20%之间,且连通孔隙占总孔隙的97%以上;未添加纤维的试块中大孔数量较少,但其体积占比较大;加入纤维后,部分大孔转化为中孔并抑制孔隙间的连通,从而改变孔隙结构。 展开更多
关键词 聚丙烯仿钢纤维透水混凝土 ct扫描 孔隙结构 透水性能
原文传递
动态小波多向感知与几何轴解引导三维CT骨折图像分割
13
作者 张印辉 刘凯 +3 位作者 何自芬 张金凯 陈光晨 马志坚 《电子与信息学报》 北大核心 2026年第3期1005-1016,共12页
三维骨折图像分割是临床骨科术前方案量化的关键,其中骨折面分割性能直接影响手术决策的安全性与有效性。针对三维骨折图像分割中存在的深层全局特征捕获不足、骨折面细节方向纹理模糊以及骨折图像几何结构利用不充分的问题,该文提出动... 三维骨折图像分割是临床骨科术前方案量化的关键,其中骨折面分割性能直接影响手术决策的安全性与有效性。针对三维骨折图像分割中存在的深层全局特征捕获不足、骨折面细节方向纹理模糊以及骨折图像几何结构利用不充分的问题,该文提出动态小波多向感知与几何轴解引导的三维CT骨折图像分割方法(Dynamic Wavelet multi-directional perception and geometry Axis-solution Guided Network,DWAG-Net)。首先,为充分提取多维度视角下全局特征,设计动态可学习参数插值重构3平面视角特征,并与全维特征聚合实现多维度提取骨折图像全局信息。其次,引入三维小波变换,通过各方向高频子带的跨子带特征融合,增强模型对模糊骨折面中方向特征的纹理细节感知。最后,根据骨骼结构相似性与骨折面局部突变性设计几何轴解引导模块,通过几何亲和与距离衰减引导模型轴解分割,并重新分配类别权重缓解其不平衡问题,约束损失函数梯度向最优方向下降。在自建胫骨骨折数据集上,DWAG-Net模型相比现有先进模型展现出优越分割性能,平均Dice Score为71.20%,其中骨折面类较基准提升了7.12%,平均HD95为1.38 mm,其中骨折面类降低了3.70 mm,与前沿3D分割算法nn WNet相比,平均Dice Score提升了4.63%。实验结果表明,DWAG-Net模型可有效实现三维骨折图像分割任务,为术前穿钉角度量化与固定位置精确选择提供了图像依据,对辅助医生优化术前方案具有重要意义。 展开更多
关键词 三维骨折分割 胫骨ct图像 动态多视角 小波感知 几何引导
在线阅读 下载PDF
基于CT扫描架倾角测量精度的自动分析算法研究
14
作者 徐小三 杜翔 +2 位作者 杨春勇 王进 洪君 《中国医学装备》 2026年第3期32-36,共5页
目的:研究提出基于客观评估X射线计算机体层扫描(CT)设备扫描架倾角精度的自动分析算法,为CT扫描架倾角测量提供优化方案。方法:采用南京医科大学附属淮安市第一人民医院的CT设备对江苏省疾病预防控制中心购置的Catphan500型检测模体进... 目的:研究提出基于客观评估X射线计算机体层扫描(CT)设备扫描架倾角精度的自动分析算法,为CT扫描架倾角测量提供优化方案。方法:采用南京医科大学附属淮安市第一人民医院的CT设备对江苏省疾病预防控制中心购置的Catphan500型检测模体进行扫描,以重建后的图像为研究对象,分别采用人工测量方法和Matlab软件自动分析算法(截面线段法和截面积法)对CT扫描架的倾角精度进行测量。将扫描架倾角(θ)的标称角度设置为5°和17°,对比分析两种方法的测量结果,及其与标称角度的偏差。结果:当θ设置为5°和17°时,人工测量实测值分别为4.04°和14.74°,与标称角度的偏差分别为0.96°和2.26°;Matlab自动分析算法中截面线段法测量值分别为4.87°和15.47°,与标称角度偏差分别为0.13°和1.53°,截面积法测量值分别为4.83°和15.47°,与标称角度偏差分别为0.17°和1.53°。当θ为17°时,Matlab自动分析算法中的截面线段法与截面积法测量结果偏差一致,均为1.53°。结论:CT扫描架倾角精度Matlab自动分析算法,无需人为干预便可自动给出CT扫描架倾角测量精度,确保CT扫描架倾角检测结果的客观准确性,能够为CT扫描架倾角测量提供优化方案。 展开更多
关键词 X射线计算机体层扫描(ct)装置 ct扫描架倾角精度 手动分析 自动分析算法
暂未订购
基于多层螺旋CT血管成像在脑卒中患者血管狭窄程度评估中的应用价值
15
作者 梅嘉 赵康 朱澍 《中国医药指南》 2026年第3期90-93,共4页
目的探讨多层螺旋CT血管成像(MSCTA)在脑卒中患者血管狭窄程度评估中应用的价值。方法将南京市江宁医院影像科2025年3月至2025年5月收治的脑卒中患者作为研究对象,共选取110例,所有患者均接受MSCTA检查。分析MSCTA对不同血管狭窄程度的... 目的探讨多层螺旋CT血管成像(MSCTA)在脑卒中患者血管狭窄程度评估中应用的价值。方法将南京市江宁医院影像科2025年3月至2025年5月收治的脑卒中患者作为研究对象,共选取110例,所有患者均接受MSCTA检查。分析MSCTA对不同血管狭窄程度的显示情况,并以数字减影血管造影(DSA)结果为金标准,分析数据并进行对比。结果以DSA检查结果为金标准,110例患者中有91例患者血管狭窄阳性,19例阴性,MSCTA检查结果有88例真阳性,18例真阴性,检查结果接近金标准,且诊断效能较高。MSCTA评估血管狭窄程度与DSA检查结果一致性较高。血管狭窄程度越严重,血管直径、CBF、CBV、PS越低(P<0.05)。结论MSCTA在脑卒中患者血管狭窄程度评估中具有较高的应用价值,能够准确显示血管狭窄程度,为临床治疗方案的制订提供重要依据。 展开更多
关键词 脑卒中 多层螺旋ct血管成像 血管狭窄程度 评估价值
暂未订购
冠状动脉CTA团注追踪阈值触发时间与CT值预测和对比剂外渗的相关性研究
16
作者 付玲 韩菲 +3 位作者 甘良英 刘卓 安备 程瑾 《中国循证心血管医学杂志》 2026年第2期195-200,共6页
目的分析CT冠状动脉造影检查中对比剂团注追踪阈值触发时间、CT值与对比剂外渗的关联性,为临床快速识别并处理对比剂外渗提供科学的参考依据。方法回顾性选取2022年1月至2023年12月于北京大学人民医院接受CT冠状动脉造影检查的1124例门... 目的分析CT冠状动脉造影检查中对比剂团注追踪阈值触发时间、CT值与对比剂外渗的关联性,为临床快速识别并处理对比剂外渗提供科学的参考依据。方法回顾性选取2022年1月至2023年12月于北京大学人民医院接受CT冠状动脉造影检查的1124例门诊患者作为研究对象,收集一般人口学资料。根据患者是否发生对比剂外渗分为外渗组和未外渗组,再根据体重指数(BMI)、对比剂注射剂量及注射速度将患者分为4个亚组(组1:BMI提示偏瘦,注射剂量为48 mL,注射速度为4 mL/s;组2:BMI提示正常,注射剂量为54 mL,注射速度为4.5 mL/s;组3:BMI提示超重,注射剂量为60 mL,注射速度为5 mL/s;组4:BMI提示肥胖,注射剂量为66 mL,注射速度为5.5 mL/s)。统计所有患者的团注追踪阈值触发时间及CT值,比较外渗组和未外渗组患者的性别、年龄、文化程度、体质指数及CT值的变化,以及4个亚组的外渗情况。采用多因素Logistic回归分析对比剂外渗的危险因素,采用多元线性回归分析CT值及触发时间的影响因素。结果在1124例患者中,发生静脉外渗者25例(2.22%)。外渗组和未外渗组患者的性别、年龄、文化程度、BMI比较,差异无统计学意义(P>0.050);两组患者的CT值比较,差异有统计学意义(P<0.050)。4个亚组的外渗情况比较,差异无统计学意义(P>0.050)。多因素回归分析结果显示,性别、年龄、BMI、文化程度、亚组均非对比剂外渗的危险因素(P>0.050)。触发时间及CT值的多元线性回归分析结果显示,性别、文化程度、BMI均非二者的影响因素(P>0.050),年龄、组别是二者的影响因素(P<0.050)。结论基于团注追踪阈值触发时间及CT值预测CT冠状动脉造影检查中的对比剂外渗具有较高的科学性,可为临床评估对比剂外渗风险提供可靠的参考依据。 展开更多
关键词 ct冠状动脉造影 对比剂 团注追踪阈值触发法 外渗 触发时间 ct
暂未订购
AI算法分析后交叉韧带胫骨撕脱骨折CT三维图像诊断及精准评估
17
作者 成永忠 李锐 +3 位作者 罗想利 王璠 陈洋 闫威 《中国组织工程研究》 北大核心 2026年第21期5589-5596,共8页
背景:后交叉韧带附着点撕脱骨折的手术决策高度依赖影像学评估,传统方法依赖CT影像进行主观判读,存在三维空间位移参数量化困难、旋转角度评估精度不足等局限,鉴于AI技术的发展,有必要开发基于AI算法的自动化、智能化影像识别软件。目的... 背景:后交叉韧带附着点撕脱骨折的手术决策高度依赖影像学评估,传统方法依赖CT影像进行主观判读,存在三维空间位移参数量化困难、旋转角度评估精度不足等局限,鉴于AI技术的发展,有必要开发基于AI算法的自动化、智能化影像识别软件。目的:探讨AI算法在CT三维图像中对后交叉韧带胫骨撕脱骨折的智能诊断能力及其对骨折块三维参数的精准评估效能。方法:回顾性纳入2022-12-01/2024-08-30在中国中医科学院望京医院就诊的24例后交叉韧带胫骨撕脱骨折患者的膝关节CT数据,使用自主研发的AI影像识别软件进行三维重建、骨折点智能识别及模拟复位,获取骨折块在X、Y、Z轴上的平移和旋转参数。与传统放射阅片软件(PACS系统)测量结果进行对比,采用秩和检验、Bland-Altman分析及线性回归模型评估两种方法的一致性,并计算变异系数验证软件稳定性。结果与结论:①AI软件与传统方法测量的骨折块位移(X/Y/Z轴平移及旋转)差异均无显著性意义(P>0.05);②Bland-Altman分析显示两种方法一致性良好,差异均无显著性意义(P>0.05);③X、Y、Z轴位移、角度两组拟合情况线性回归模型R^(2)值均>0.99;④AI软件重复3次骨折点识别的变异系数显示:总骨折识别时21例影像资料的变异系数<20%,识别关节面骨折点时18例变异系数<20%;⑤表明AI影像识别软件可精准量化后交叉韧带撕脱骨折块的三维参数,其测量结果与传统方法一致且稳定性良好,可辅助医生判断移位程度,为术前规划提供精准数据支持;该软件在撕脱骨折中有良好的应用前景,未来需扩大样本量并进一步验证其对手术疗效的影响。 展开更多
关键词 后交叉韧带撕脱骨折 人工智能 ct影像识别 三维测量 术前规划
暂未订购
精细化护理在增强CT造影剂外渗护理中的应用效果观察
18
作者 赵春生 赵立森 +1 位作者 彭双双 黄国芳 《首都食品与医药》 2026年第2期103-106,共4页
目的分析精细化护理在增强CT造影剂外渗护理中的应用效果。方法选取首都医科大学附属北京胸科医院2023年11月-2024年11月患者68例,随机分为两组,每组34例,对照组予以常规护理,观察组予以精细化护理,对比其护理效果。结果观察组并发症发... 目的分析精细化护理在增强CT造影剂外渗护理中的应用效果。方法选取首都医科大学附属北京胸科医院2023年11月-2024年11月患者68例,随机分为两组,每组34例,对照组予以常规护理,观察组予以精细化护理,对比其护理效果。结果观察组并发症发生率低于对照组;消极情绪评分低于对照组;护理满意度高于对照组;护理质量高于对照组(P<0.05)。结论在增强CT造影剂外渗中实行精细化护理,其临床价值显著,可有效提升护理质量,并改善患者消极情绪,值得推广。 展开更多
关键词 精细化护理 增强ct 造影剂 外渗 应用效果
暂未订购
第三代双源CT能谱纯化(Sn150 kVp)大螺距扫描模式下冠状动脉钙化积分的准确性与剂量评估:与标准120 kVp的配对研究
19
作者 胡溪 张月俏 +1 位作者 陈彬 任宏 《全科医学临床与教育》 2026年第3期205-209,F0002,共6页
目的评估CT能谱纯化联合大螺距(UHP)Sn150 kVp扫描模式下冠状动脉钙化积分的准确性及其降低辐射剂量的潜力。方法纳入125名临床怀疑冠心病的患者,进行标准120 kVp扫描和UHP Sn150 kVp扫描,测量钙化积分(体积积分、质量积分和Agatston积... 目的评估CT能谱纯化联合大螺距(UHP)Sn150 kVp扫描模式下冠状动脉钙化积分的准确性及其降低辐射剂量的潜力。方法纳入125名临床怀疑冠心病的患者,进行标准120 kVp扫描和UHP Sn150 kVp扫描,测量钙化积分(体积积分、质量积分和Agatston积分),并对患者进行风险分层。通过组内相关系数(ICC)和加权Kappa来评估一致性,Spearman检验评估相关性,并比较两种模式下的辐射剂量。结果尽管UHP Sn150 kVp扫描模式较标准120 kVp扫描模式获得的体积积分、质量积分和Agatston积分的数值明显降低(Z分别=8.21、4.41、8.22,P均<0.05),但两种扫描模式所得钙化积分一致性和相关性良好(ICC=0.97,95%CI 0.96~0.98;r=0.98,95%CI 0.97~0.98),且风险分层一致性良好(加权Kappa=0.82)。与标准120 kVp扫描模式相比,UHP Sn150 kVp扫描模式的辐射有效剂量从0.82 mSv降至0.58 mSv,降低约30%(Z=9.19,P<0.05)。结论UHP Sn150 kVp相较120 kVp在三类钙化积分上呈系统性偏低,但保持优良风险分层一致性,且有效剂量降低约30%。 展开更多
关键词 双源ct 冠状动脉钙化 Agatston积分 辐射剂量
暂未订购
上一页 1 2 250 下一页 到第
使用帮助 返回顶部