Thermal storage electric heating(TSEH),as a prevalent variable load resource,offers significant potential for enhancing system flexibility when aggregated into a cluster.To address the uncertainties of renewable energ...Thermal storage electric heating(TSEH),as a prevalent variable load resource,offers significant potential for enhancing system flexibility when aggregated into a cluster.To address the uncertainties of renewable energy and load forecasting in active distribution networks(ADN),this paper proposes a multi-timescale coordinated optimal dispatch strategy that incorporates TSEH clusters.It utilizes the thermal storage characteristics and short-term regulation capabilities of TSEH,along with the rapid and gradual response characteristics of resources in active distribution grids,to develop a coordinated optimization dispatch mechanism for day-ahead,intraday,and real-time stages.It provides a coordinated optimized dispatch technique across several timescales for active distribution grids,taking into account the integration of TSEH clusters.The proposed method is validated on a modified IEEE 33-node system.Simulation results demonstrate that the participation of TSEH in collaborative optimization significantly reduces the total system operating cost by 8.71%compared to the scenario without TSEH.This cost reduction is attributed to a 10.84%decrease in interaction costs with the main grid and a 47.41%reduction in network loss costs,validating effective peak shaving and valley filling.The multi-timescale framework further enhances economic efficiency,with overall operating costs progressively decreasing by 3.91%(intraday)and 4.59%(real-time),and interaction costs further reduced by 5.34%and 9.25%,respectively.Moreover,the approach enhances system stability by effectively suppressing node voltage fluctuations and ensuring all voltages remain within safe operating limits during real-time operation.Therefore,the proposed approach achieves rational coordination of diverse resources,significantly improving the economic efficiency and stability of ADNs.展开更多
The volatility introduced by the integration of renewable energy poses challenges to the reliability of power supply,increasing the demand for energy storage in distribution networks.Shared energy storage in distribut...The volatility introduced by the integration of renewable energy poses challenges to the reliability of power supply,increasing the demand for energy storage in distribution networks.Shared energy storage in distribution networks can participate in energy storage allocation as a provider of reliability ancillary services.This paper proposes a novel Nash bargaining based energy storage coordinated allocation method to fully incentivize shared energy storage to participate in reliability services within the distribution network.First,an analytical reliability assessment model is constructed and embedded into the energy storage allocation model,where the impact of renewable energy uncertainty is described using chance constraints.Considering the interests of both the distribution network and shared energy storage operators,a Nash bargaining based energy storage coordinated allocation and benefit sharing mechanism is established,which is then transformed into a mixed-integer linear programming(MILP)model for efficient solution.Case studies show that the proposed method,through cooperation between the distribution system operator and shared energy storage operators,signif-icantly reduces investment cost of energy storage and ensures a rational distribution of the benefits obtained.展开更多
Grid-scale energy storage systems provide effective solutions to address challenges such as supply-load imbalances and voltage violations resulting from the non-coinciding nature of renewable energy generation and pea...Grid-scale energy storage systems provide effective solutions to address challenges such as supply-load imbalances and voltage violations resulting from the non-coinciding nature of renewable energy generation and peak demand incidents.While battery and hydrogen storage are commonly used for peak shaving,ice-based thermal energy storage systems(TESSs)offer a direct way to reduce cooling loads without electrical conversion.This paper presents a multi-objective planning framework that optimizes TESS dispatch,network topology,and photovoltaic(PV)inverter reactive power support to address operational issues in active distribution networks.The objectives of the proposed scheme include minimizing peak demand,voltage deviations,and PV inverter VAr dependency.The mixed-integer nonlinear programming problem is solved using a Pareto-based multi-objective particle swarm optimization(MOPSO)method.The MATLAB-OpenDSS simulations for a modified IEEE-123 bus system show a 7.1%reduction in peak demand,a 13%reduction in voltage deviation,and a 52%drop in PV inverter VAr usage.The obtained solutions confirm minimal operational stress on control devices such as switches and PV inverters.Thus,unlike earlier studies,this work combines all three strategies to offer an effective solution for the operational planning of the active distribution network.展开更多
Based on the energy storage cloud platform architecture,this study considers the extensive configuration of energy storage devices and the future large-scale application of electric vehicles at the customer side to bu...Based on the energy storage cloud platform architecture,this study considers the extensive configuration of energy storage devices and the future large-scale application of electric vehicles at the customer side to build a new mode of smart power consumption with a flexible interaction,smooth the peak/valley difference of the load side power,and improve energy efficiency.A plug and play device for customer-side energy storage and an internet-based energy storage cloud platform are developed herein to build a new intelligent power consumption mode with a flexible interaction suitable for ordinary customers.Based on the load perception of the power grid,this study aims to investigate the operating state and service life of distributed energy storage devices.By selecting an integrated optimal control scheme,this study designs a kind of energy optimization and deployment strategy for stratified partition to reduce the operating cost of the energy storage device on the client side.The effectiveness of the system and the control strategy is verified through the Suzhou client-side distributed energy storage demonstration project.展开更多
Distributed collaborative control strategies for microgrids often use periodic time to trigger communication,which is likely to enhance the burden of communication and increase the frequency of controller updates,lead...Distributed collaborative control strategies for microgrids often use periodic time to trigger communication,which is likely to enhance the burden of communication and increase the frequency of controller updates,leading to greater waste of communication resources.In response to this problem,a distributed cooperative control strategy triggered by an adaptive event is proposed.By introducing an adaptive event triggering mechanism in the distributed controller,the triggering parameters are dynamically adjusted so that the distributed controller can communicate only at a certain time,the communication pressure is reduced,and the DC bus voltage deviation is effectively reduced,at the same time,the accuracy of power distribution is improved.The MATLAB/Simulink modeling and simulation results prove the correctness and effectiveness of the proposed control strategy.展开更多
The penetration rate of distributed generation is gradually increasing in the distribution system concerned.This is creating new problems and challenges in the planning and operation of the system.The intermittency an...The penetration rate of distributed generation is gradually increasing in the distribution system concerned.This is creating new problems and challenges in the planning and operation of the system.The intermittency and variability of power outputs from numerous distributed renewable generators could significantly jeopardize the secure operation of the distribution system.Therefore,it is necessary to assess the hosting capability for intermittent distributed generation by a distribution system considering operational constraints.This is the subject of this study.An assessment model considering the uncertainty of generation outputs from distributed generators is presented for this purpose.It involves different types of regulation or control functions using on-load tap-changers(OLTCs),reactive power compensation devices,energy storage systems,and the reactive power support of the distributed generators employed.A robust optimization model is then attained It is solved by Bertsimas robust counterpart through GUROBI solver.Finally,the feasibility and efficiency of the proposed method are demonstrated by a modified IEEE 33-bus distribution system.In addition,the effects of the aforementioned regulation or control functions on the enhancement of the hosting capability for intermittent distributed generation are examined.展开更多
There is instability in the distributed energy storage cloud group end region on the power grid side.In order to avoid large-scale fluctuating charging and discharging in the power grid environment and make the capaci...There is instability in the distributed energy storage cloud group end region on the power grid side.In order to avoid large-scale fluctuating charging and discharging in the power grid environment and make the capacitor components showa continuous and stable charging and discharging state,a hierarchical time-sharing configuration algorithm of distributed energy storage cloud group end region on the power grid side based on multi-scale and multi feature convolution neural network is proposed.Firstly,a voltage stability analysis model based onmulti-scale and multi feature convolution neural network is constructed,and the multi-scale and multi feature convolution neural network is optimized based on Self-OrganizingMaps(SOM)algorithm to analyze the voltage stability of the cloud group end region of distributed energy storage on the grid side under the framework of credibility.According to the optimal scheduling objectives and network size,the distributed robust optimal configuration control model is solved under the framework of coordinated optimal scheduling at multiple time scales;Finally,the time series characteristics of regional power grid load and distributed generation are analyzed.According to the regional hierarchical time-sharing configuration model of“cloud”,“group”and“end”layer,the grid side distributed energy storage cloud group end regional hierarchical time-sharing configuration algorithm is realized.The experimental results show that after applying this algorithm,the best grid side distributed energy storage configuration scheme can be determined,and the stability of grid side distributed energy storage cloud group end region layered timesharing configuration can be improved.展开更多
The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,...The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,photovoltaic power generation is unstable and random,resulting in a low utilization rate and directly affecting the stability of the power grid.To solve this problem,this paper proposes a coordinated control strategy for a newenergy power generation system with a hybrid energy storage unit based on the lithium iron phosphate-supercapacitor hybrid energy storage unit.Firstly,the variational mode decomposition algorithm is used to separate the high and low frequencies of the power signal,which is conducive to the rapid and accurate suppression of the power fluctuation of the energy storage system.Secondly,the fuzzy control algorithm is introduced to balance the power between energy storage.In this paper,the actual data is used for simulation,and the simulation results show that the strategy realizes the effective suppression of the bus voltage fluctuation and the accurate control of the internal state of the energy storage unit,effectively avoiding problems such as overshoot and over-discharge,and can significantly improve the stability of the photovoltaic power generation systemand the stability of the Direct Current bus.It is of great significance to promote the development of collaborative control technology for photovoltaic hybrid energy storage units.展开更多
To adapt to the uncertainty of new energy,increase new energy consumption,and reduce carbon emissions,a high-voltage distribution network energy storage planning model based on robustness-oriented planning and distrib...To adapt to the uncertainty of new energy,increase new energy consumption,and reduce carbon emissions,a high-voltage distribution network energy storage planning model based on robustness-oriented planning and distributed new energy consumption is proposed.Firstly,the spatio-temporal correlation of large-scale wind-photovoltaic energy is modeled based on the Vine Copula model,and the spatial correlation of the generated wind-photovoltaic power generation is corrected to get the spatio-temporal correlation of wind-photovoltaic power generation scenarios.Finally,considering the subsequent development of new energy on demand for high-voltage distribution network peaking margin and the economy of the system peaking,we propose the optimization model of high-voltage distribution network energy storage plant siting and capacity setting for source-storage cooperative peaking.The simulation results show that the proposed energy storage plant planning method can effectively alleviate the branch circuit blockage,promote new energy consumption,reduce the burden of the main grid peak shifting,and leave sufficient peak shifting margin for the subsequent development of a new energy distribution network while ensuring the economy.展开更多
In high-renewable-energy power systems,the demand for fast-responding capabilities is growing.To address the limitations of conventional closed-loop frequency control,where the integral coefficient cannot dynamically ...In high-renewable-energy power systems,the demand for fast-responding capabilities is growing.To address the limitations of conventional closed-loop frequency control,where the integral coefficient cannot dynamically adjust the frequency regulation command based on the state of charge(SoC)of energy storage units,this paper proposes a secondary frequency regulation control strategy based on variable integral coefficients for multiple energy storage units.First,a power-uniform controller is designed to ensure that thermal power units gradually take on more regulation power during the frequency regulation process.Next,a control framework based on variable integral coefficients is proposed within the secondary frequency regulation model,along with an objective function that simultaneously considers both Automatic Generation Control(AGC)command tracking performance and SoC recovery requirements of energy storage units.Finally,a gradient descent optimization method is used to dynamically adjust the gain of the energy storage integral controller,allowingmultiple energy storage units to respond in real-time to AGC instructions and SoC variations.Simulation results confirmthe effectiveness of the proposedmethod.Compared to traditional strategies,the proposed approach takes into account the SoCdiscrepancies amongmultiple energy storage units and the duration of system net power imbalances.It successfully implements secondary frequency regulation while achieving dynamic power allocation among the units.展开更多
The increasing proportion of distributed photovoltaics(DPVs)and electric vehicle charging stations in low-voltage distribution networks(LVDNs)has resulted in challenges such as distribution transformer overloads and v...The increasing proportion of distributed photovoltaics(DPVs)and electric vehicle charging stations in low-voltage distribution networks(LVDNs)has resulted in challenges such as distribution transformer overloads and voltage violations.To address these problems,we propose a coordinated planning method for flexible interconnections and energy storage systems(ESSs)to improve the accommodation capacity of DPVs.First,the power-transfer characteristics of flexible interconnection and ESSs are analyzed.The equipment costs of the voltage source converters(VSCs)and ESSs are also analyzed comprehensively,considering the differences in installation and maintenance costs for different installation locations.Second,a bilevel programming model is established to minimize the annual comprehensive cost and yearly total PV curtailment capacity.Within this framework,the upper-level model optimizes the installation locations and capacities of the VSCs and ESSs,whereas the lower-level model optimizes the operating power of the VSCs and ESSs.The proposed model is solved using a non-dominated sorting genetic algorithm with an elite strategy(NSGA-II).The effectiveness of the proposed planning method is validated through an actual LVDN scenario,which demonstrates its advantages in enhancing PV accommodation capacity.In addition,the economic benefits of various planning schemes with different flexible interconnection topologies and different PV grid-connected forms are quantitatively analyzed,demonstrating the adaptability of the proposed coordinated planning method.展开更多
With the growing deployment of smart distribution grid,it has become urgent to investigate the smart distribution grid behavior during transient faults and improve the system stability.The feasibility of segmenting la...With the growing deployment of smart distribution grid,it has become urgent to investigate the smart distribution grid behavior during transient faults and improve the system stability.The feasibility of segmenting large power grids and multiple smart distribution grids interconnections using energy storage technology for improving the system dynamic stability was studied.The segmentation validity of the large power grids and smart distribution grid inverter output interconnections power system using energy storage technology was proved in terms of theoretical analysis.Then,the influences of the energy storage device location and capacity on the proposed method were discussed in detail.The conclusion is obtained that the ESD optimal locations are allocated at the tie line terminal buses in the interconnected grid,respectively.The effectiveness of the proposed method was verified by simulations in an actual power system.展开更多
Energy storage (ES) is a form of media that store one form of energy to be utilized at another time. Importance of ES is comprehended while intermittent nature of renewable energy (RE) generation increases and integra...Energy storage (ES) is a form of media that store one form of energy to be utilized at another time. Importance of ES is comprehended while intermittent nature of renewable energy (RE) generation increases and integration into the grid becomes viable in terms of economics and environment. However, technical analysis should be carried out before large scale integration into the grid. Some utilities experienced in Europe and expressed concern about issues in integrating large scale renewable energy in the areas of harmonics, voltage regulation, network protection and islanding. In Australia, distribution network (DN) is not robust compared to the European grid;moreover loads are largely distributed over large geographical areas. Installation of RE such as roof top solar photovoltaic (PV) is increasing in Australia which also boosted by the governments incentives to the individual owners. It is therefore obvious that large scale PV integration into the Australian grid is imminent. The intermittent characteristic of solar PV is expected to have greater impacts on DN in Australia compared to the DN in Europe. Therefore this paper investigated the impacts of solar PV on low voltage (LV) DN where loads connected through distribution transformer (DT) and finally further investigation was conducted with the deployment of ES into the respective load centers. It was found that storage reduced the overall peak load condition on the DT, and also reduced the energy fluctuation in the DN. It was also found that storage improved the voltage regulation on the LV side of DT and stabilized node voltage.展开更多
A smart grid will require, to greater or lesser degrees, advanced tools for planning and operation, broadly accepted communications platforms, smart sensors and controls, and real-time pricing. The smart grid has been...A smart grid will require, to greater or lesser degrees, advanced tools for planning and operation, broadly accepted communications platforms, smart sensors and controls, and real-time pricing. The smart grid has been described as something of an ecosystem with constantly communication, proactive, and virtually self-aware. The use of smart grid has a lot of economical and environmental advantages;however it has a downside of instability and unpredictability introduced by distributed generation (DG) from renewable energy into the public electric systems. Variable energies such as solar and wind power have a lack of stability and to avoid short-term fluctuations in power supplied to the grid, a local storage subsystem could be used to provide higher quality and stability in the fed energy. Energy storage systems (ESSs) would be a facilitator of smart grid deployment and a “small amount” of storage would have a “great impact” on the future power grid. The smart grid, with its various superior communications and control features, would make it possible to integrate the potential application of widely dispersed battery storage systems as well other ESSs. This work deals with a detailed updated review on available ESSs applications in future smart power grids. It also highlights latest projects carried out on different ESSs throughout all around the world.展开更多
To address the frequency fluctuation problem caused by the power dynamic imbalance between the power system and the loadwhen a large number of newenergy sources are connected to the grid,a two-layer fuzzy control stra...To address the frequency fluctuation problem caused by the power dynamic imbalance between the power system and the loadwhen a large number of newenergy sources are connected to the grid,a two-layer fuzzy control strategy is proposed for the participation of the energy storage battery system in FM.Firstly,considering the coordination of FM units responding to automatic power generation control commands,a comprehensive allocation strategy of two signals under automatic power generation control commands is proposed to give full play to the advantages of two FM signals while enabling better coordination of two FM units responding to FM commands;secondly,based on the grid FM demand and battery FM capability,a double-layer fuzzy control strategy is proposed for FM units responding to automatic power generation control commands in a coordinated manner under dual-signal allocation mode to precisely allocate the power output depth of FM units,which can control the fluctuation of frequency deviation within a smaller range at a faster speed while maintaining the battery charge state;finally,the proposed Finally,the proposed control strategy is simulated and verified inMatlab/Simulink.The results show that the proposed control strategy can control the frequency deviation within a smaller range in a shorter time,better stabilize the fluctuation of the battery charge level,and improve the utilization of the FM unit.展开更多
This paper discusses the future power system consisting of distributed generations connected to local loads in the form of micro-grid systems.The benefits of having energy storage systems and the role of power electro...This paper discusses the future power system consisting of distributed generations connected to local loads in the form of micro-grid systems.The benefits of having energy storage systems and the role of power electronics in micro-grid systems are presented.This paper also examines how micro-grids have a key role to play in the development of the smart grid.展开更多
The experiment is studied on thermal distribution in the thermal energy storage system with non-phase change materials (NPCM): NaNO3, KNO3 and NaCl in the range of 25°C - 250°C. The cylindrical storage syste...The experiment is studied on thermal distribution in the thermal energy storage system with non-phase change materials (NPCM): NaNO3, KNO3 and NaCl in the range of 25°C - 250°C. The cylindrical storage system was made of stainless steel with 25.6 cm-diameter and 26.8 cm-height that was contained of these NPCM. There was one pipe for heat transfer fluid (HTF) with 1.27 cm-diameter that manipulates in the storage tank and submerges to NPCM. The inner pipe was connected to the 2.27 cm-diameter outer HTF tube. The tube was further connected to the thermal pump, heater and load. The pump circulates the synthetic oil (Thermia oil) within the pipe for heat transferring purposes (charging and discharging). An electric heater is used as the heat source. The limitation of the charging oil temperature is maintained at 250°C with the flow rates in the range of 0.58 to 1.45 kg/s whereas the inlet temperature of the discharge oil is maintained at 25°C. Thermal performances of TES (thermal energy storage) such as charging and discharging times, radial thermal distribution, energy storage capacity and energy efficiency have been evaluated. The experimental results show that the radial thermal distribution of NaCl for TR inside, TR middle and TR outside was optimum of temperature down to NaNO3 and KNO3 respectively. Comparison of NPCMs with oil, flow rates for NaCl were charging and discharging heat transfer than KNO3 and NaNO3. The thermal stored NaCl ranged from 5712 - 5912 J;KNO3 ranged from 7350 - 7939 J and NaNO3 ranged from 6623 - 6930 J respectively. The thermal energy stored for experimental results got with along the KNO3, NaNO3 and NaCl respectively. The thermal energy efficiency of NaCl, KNO3 and NaNO3 was in the range 66% - 70%.展开更多
With certain controllability of various distribution energy resources (DERs) such as battery energy storage system (BESS), demand response (DR) and distributed generations (DGs), virtual power plant (VPP) can suitably...With certain controllability of various distribution energy resources (DERs) such as battery energy storage system (BESS), demand response (DR) and distributed generations (DGs), virtual power plant (VPP) can suitably regulate the powers access to the distribution network. In this paper, an optimal VPP operating problem is used to optimize the charging/discharging schedule of each BESS and the DR scheme with the objective to maximize the benefit by regulating the supplied powers over daily 24 hours. The proposed solution method is composed of an iterative dynamic programming optimal BESS schedule approach and a particle swarm optimization based (PSO-based) DR scheme approach. The two approaches are executed alternatively until the minimum elec-tricity cost of the whole day is obtained. The validity of the proposed method was confirmed with the obviously decreased supplied powers in the peak-load hours and the largely reduced electricity cost.展开更多
As part of the ongoing information revolution,smart power grid technology has become a key focus area for research into power systems.Intelligent electrical appliances are now an important component of power systems,p...As part of the ongoing information revolution,smart power grid technology has become a key focus area for research into power systems.Intelligent electrical appliances are now an important component of power systems,providing a smart power grid with increased control,stability,and safety.Based on the secure communication requirements of cloud energy storage systems,this paper presents the design and development of a node controller for a cloud energy storage network.The function division and system deployment processes were carried out to ensure the security of the communication network used for the cloud energy storage system.Safety protection measures were proposed according to the demands of the communication network,allowing the system to run safely and stably.Finally,the effectiveness of the system was verified through a client-side distributed energy storage demonstration project in Suzhou,China.The system was observed to operate safely and stably,demonstrating good peak-clipping and valley filling effects,and improving the system load characteristics.展开更多
Variable distributed energy resources (DERs) such as photovoltaic (PV) systems and wind power systems require additional power resources to control the balance between supply and demand. Battery energy storage systems...Variable distributed energy resources (DERs) such as photovoltaic (PV) systems and wind power systems require additional power resources to control the balance between supply and demand. Battery energy storage systems (BESSs) are one such possible resource for providing grid stability. It has been proposed that decentralized BESSs could help support microgrids (MGs) with intelligent control when advanced functionalities are implemented with variable DERs. One key challenge is developing and testing smart inverter controls for DERs. This paper presents a standardized method to test the interoperability and functionality of BESSs. First, a survey of grid-support standards prevalent in several countries was conducted. Then, the following four interoperability functions defined in IEC TR 61850-90-7 were tested: the specified active power from storage test (INV4), the var-priority Volt/VAR test (VV) and the specified power factor test (INV3) and frequency-watt control (FW). This study then out-lines the remaining technical issues related to basic BESS smart inverter test protocols.展开更多
基金supported by Integrated Distribution Network Planning and Operational Enhancement Using Flexibility Domains Under Deep Human-Vehicle-Charger-Road-Grid Coupling(U22B20105).
文摘Thermal storage electric heating(TSEH),as a prevalent variable load resource,offers significant potential for enhancing system flexibility when aggregated into a cluster.To address the uncertainties of renewable energy and load forecasting in active distribution networks(ADN),this paper proposes a multi-timescale coordinated optimal dispatch strategy that incorporates TSEH clusters.It utilizes the thermal storage characteristics and short-term regulation capabilities of TSEH,along with the rapid and gradual response characteristics of resources in active distribution grids,to develop a coordinated optimization dispatch mechanism for day-ahead,intraday,and real-time stages.It provides a coordinated optimized dispatch technique across several timescales for active distribution grids,taking into account the integration of TSEH clusters.The proposed method is validated on a modified IEEE 33-node system.Simulation results demonstrate that the participation of TSEH in collaborative optimization significantly reduces the total system operating cost by 8.71%compared to the scenario without TSEH.This cost reduction is attributed to a 10.84%decrease in interaction costs with the main grid and a 47.41%reduction in network loss costs,validating effective peak shaving and valley filling.The multi-timescale framework further enhances economic efficiency,with overall operating costs progressively decreasing by 3.91%(intraday)and 4.59%(real-time),and interaction costs further reduced by 5.34%and 9.25%,respectively.Moreover,the approach enhances system stability by effectively suppressing node voltage fluctuations and ensuring all voltages remain within safe operating limits during real-time operation.Therefore,the proposed approach achieves rational coordination of diverse resources,significantly improving the economic efficiency and stability of ADNs.
基金supported in part by the National Science Foundation of China(Grant.U24B6009)Beijing Natural Science Foundation(L243003).
文摘The volatility introduced by the integration of renewable energy poses challenges to the reliability of power supply,increasing the demand for energy storage in distribution networks.Shared energy storage in distribution networks can participate in energy storage allocation as a provider of reliability ancillary services.This paper proposes a novel Nash bargaining based energy storage coordinated allocation method to fully incentivize shared energy storage to participate in reliability services within the distribution network.First,an analytical reliability assessment model is constructed and embedded into the energy storage allocation model,where the impact of renewable energy uncertainty is described using chance constraints.Considering the interests of both the distribution network and shared energy storage operators,a Nash bargaining based energy storage coordinated allocation and benefit sharing mechanism is established,which is then transformed into a mixed-integer linear programming(MILP)model for efficient solution.Case studies show that the proposed method,through cooperation between the distribution system operator and shared energy storage operators,signif-icantly reduces investment cost of energy storage and ensures a rational distribution of the benefits obtained.
基金supported by the US Appalachian Regional Commission(ARC)under Grant MU-21579-23。
文摘Grid-scale energy storage systems provide effective solutions to address challenges such as supply-load imbalances and voltage violations resulting from the non-coinciding nature of renewable energy generation and peak demand incidents.While battery and hydrogen storage are commonly used for peak shaving,ice-based thermal energy storage systems(TESSs)offer a direct way to reduce cooling loads without electrical conversion.This paper presents a multi-objective planning framework that optimizes TESS dispatch,network topology,and photovoltaic(PV)inverter reactive power support to address operational issues in active distribution networks.The objectives of the proposed scheme include minimizing peak demand,voltage deviations,and PV inverter VAr dependency.The mixed-integer nonlinear programming problem is solved using a Pareto-based multi-objective particle swarm optimization(MOPSO)method.The MATLAB-OpenDSS simulations for a modified IEEE-123 bus system show a 7.1%reduction in peak demand,a 13%reduction in voltage deviation,and a 52%drop in PV inverter VAr usage.The obtained solutions confirm minimal operational stress on control devices such as switches and PV inverters.Thus,unlike earlier studies,this work combines all three strategies to offer an effective solution for the operational planning of the active distribution network.
基金supported by the State Grid Corporation of China Science and Technological Project(Research and demonstration application of key technology of energy storage cloud for mobile energy storage application of electric vehicles 5419-20197121 7a-0-0-00)
文摘Based on the energy storage cloud platform architecture,this study considers the extensive configuration of energy storage devices and the future large-scale application of electric vehicles at the customer side to build a new mode of smart power consumption with a flexible interaction,smooth the peak/valley difference of the load side power,and improve energy efficiency.A plug and play device for customer-side energy storage and an internet-based energy storage cloud platform are developed herein to build a new intelligent power consumption mode with a flexible interaction suitable for ordinary customers.Based on the load perception of the power grid,this study aims to investigate the operating state and service life of distributed energy storage devices.By selecting an integrated optimal control scheme,this study designs a kind of energy optimization and deployment strategy for stratified partition to reduce the operating cost of the energy storage device on the client side.The effectiveness of the system and the control strategy is verified through the Suzhou client-side distributed energy storage demonstration project.
基金funded by the Natural Science Foundation of Shaanxi Province,Grant No.2021GY-135the Scientific Research Project of Yan’an University,Grant No.YDQ2018-07.
文摘Distributed collaborative control strategies for microgrids often use periodic time to trigger communication,which is likely to enhance the burden of communication and increase the frequency of controller updates,leading to greater waste of communication resources.In response to this problem,a distributed cooperative control strategy triggered by an adaptive event is proposed.By introducing an adaptive event triggering mechanism in the distributed controller,the triggering parameters are dynamically adjusted so that the distributed controller can communicate only at a certain time,the communication pressure is reduced,and the DC bus voltage deviation is effectively reduced,at the same time,the accuracy of power distribution is improved.The MATLAB/Simulink modeling and simulation results prove the correctness and effectiveness of the proposed control strategy.
基金the Scientific and Technological Project of SGCC Headquarters entitled“Smart Distribution Network and Ubiquitous Power Internet of Things Integrated Development Collaborative Planning Technology Research”(5400-201956447A-0-0-00).
文摘The penetration rate of distributed generation is gradually increasing in the distribution system concerned.This is creating new problems and challenges in the planning and operation of the system.The intermittency and variability of power outputs from numerous distributed renewable generators could significantly jeopardize the secure operation of the distribution system.Therefore,it is necessary to assess the hosting capability for intermittent distributed generation by a distribution system considering operational constraints.This is the subject of this study.An assessment model considering the uncertainty of generation outputs from distributed generators is presented for this purpose.It involves different types of regulation or control functions using on-load tap-changers(OLTCs),reactive power compensation devices,energy storage systems,and the reactive power support of the distributed generators employed.A robust optimization model is then attained It is solved by Bertsimas robust counterpart through GUROBI solver.Finally,the feasibility and efficiency of the proposed method are demonstrated by a modified IEEE 33-bus distribution system.In addition,the effects of the aforementioned regulation or control functions on the enhancement of the hosting capability for intermittent distributed generation are examined.
基金supported by State Grid Corporation Limited Science and Technology Project Funding(Contract No.SGCQSQ00YJJS2200380).
文摘There is instability in the distributed energy storage cloud group end region on the power grid side.In order to avoid large-scale fluctuating charging and discharging in the power grid environment and make the capacitor components showa continuous and stable charging and discharging state,a hierarchical time-sharing configuration algorithm of distributed energy storage cloud group end region on the power grid side based on multi-scale and multi feature convolution neural network is proposed.Firstly,a voltage stability analysis model based onmulti-scale and multi feature convolution neural network is constructed,and the multi-scale and multi feature convolution neural network is optimized based on Self-OrganizingMaps(SOM)algorithm to analyze the voltage stability of the cloud group end region of distributed energy storage on the grid side under the framework of credibility.According to the optimal scheduling objectives and network size,the distributed robust optimal configuration control model is solved under the framework of coordinated optimal scheduling at multiple time scales;Finally,the time series characteristics of regional power grid load and distributed generation are analyzed.According to the regional hierarchical time-sharing configuration model of“cloud”,“group”and“end”layer,the grid side distributed energy storage cloud group end regional hierarchical time-sharing configuration algorithm is realized.The experimental results show that after applying this algorithm,the best grid side distributed energy storage configuration scheme can be determined,and the stability of grid side distributed energy storage cloud group end region layered timesharing configuration can be improved.
基金supported by the State Grid Corporation of China Science and Technology Project,grant number 52270723000900K.
文摘The new energy power generation is becoming increasingly important in the power system.Such as photovoltaic power generation has become a research hotspot,however,due to the characteristics of light radiation changes,photovoltaic power generation is unstable and random,resulting in a low utilization rate and directly affecting the stability of the power grid.To solve this problem,this paper proposes a coordinated control strategy for a newenergy power generation system with a hybrid energy storage unit based on the lithium iron phosphate-supercapacitor hybrid energy storage unit.Firstly,the variational mode decomposition algorithm is used to separate the high and low frequencies of the power signal,which is conducive to the rapid and accurate suppression of the power fluctuation of the energy storage system.Secondly,the fuzzy control algorithm is introduced to balance the power between energy storage.In this paper,the actual data is used for simulation,and the simulation results show that the strategy realizes the effective suppression of the bus voltage fluctuation and the accurate control of the internal state of the energy storage unit,effectively avoiding problems such as overshoot and over-discharge,and can significantly improve the stability of the photovoltaic power generation systemand the stability of the Direct Current bus.It is of great significance to promote the development of collaborative control technology for photovoltaic hybrid energy storage units.
基金supported by State Grid Anhui Electric Power Co.,Ltd.Research Program(B3120923000C).
文摘To adapt to the uncertainty of new energy,increase new energy consumption,and reduce carbon emissions,a high-voltage distribution network energy storage planning model based on robustness-oriented planning and distributed new energy consumption is proposed.Firstly,the spatio-temporal correlation of large-scale wind-photovoltaic energy is modeled based on the Vine Copula model,and the spatial correlation of the generated wind-photovoltaic power generation is corrected to get the spatio-temporal correlation of wind-photovoltaic power generation scenarios.Finally,considering the subsequent development of new energy on demand for high-voltage distribution network peaking margin and the economy of the system peaking,we propose the optimization model of high-voltage distribution network energy storage plant siting and capacity setting for source-storage cooperative peaking.The simulation results show that the proposed energy storage plant planning method can effectively alleviate the branch circuit blockage,promote new energy consumption,reduce the burden of the main grid peak shifting,and leave sufficient peak shifting margin for the subsequent development of a new energy distribution network while ensuring the economy.
文摘In high-renewable-energy power systems,the demand for fast-responding capabilities is growing.To address the limitations of conventional closed-loop frequency control,where the integral coefficient cannot dynamically adjust the frequency regulation command based on the state of charge(SoC)of energy storage units,this paper proposes a secondary frequency regulation control strategy based on variable integral coefficients for multiple energy storage units.First,a power-uniform controller is designed to ensure that thermal power units gradually take on more regulation power during the frequency regulation process.Next,a control framework based on variable integral coefficients is proposed within the secondary frequency regulation model,along with an objective function that simultaneously considers both Automatic Generation Control(AGC)command tracking performance and SoC recovery requirements of energy storage units.Finally,a gradient descent optimization method is used to dynamically adjust the gain of the energy storage integral controller,allowingmultiple energy storage units to respond in real-time to AGC instructions and SoC variations.Simulation results confirmthe effectiveness of the proposedmethod.Compared to traditional strategies,the proposed approach takes into account the SoCdiscrepancies amongmultiple energy storage units and the duration of system net power imbalances.It successfully implements secondary frequency regulation while achieving dynamic power allocation among the units.
基金supported by the Science and Technology Support Program of Guizhou Province([2022]General 012)the Key Science and Technology Project of China Southern Power Grid Corporation(GZKJXM20220043)。
文摘The increasing proportion of distributed photovoltaics(DPVs)and electric vehicle charging stations in low-voltage distribution networks(LVDNs)has resulted in challenges such as distribution transformer overloads and voltage violations.To address these problems,we propose a coordinated planning method for flexible interconnections and energy storage systems(ESSs)to improve the accommodation capacity of DPVs.First,the power-transfer characteristics of flexible interconnection and ESSs are analyzed.The equipment costs of the voltage source converters(VSCs)and ESSs are also analyzed comprehensively,considering the differences in installation and maintenance costs for different installation locations.Second,a bilevel programming model is established to minimize the annual comprehensive cost and yearly total PV curtailment capacity.Within this framework,the upper-level model optimizes the installation locations and capacities of the VSCs and ESSs,whereas the lower-level model optimizes the operating power of the VSCs and ESSs.The proposed model is solved using a non-dominated sorting genetic algorithm with an elite strategy(NSGA-II).The effectiveness of the proposed planning method is validated through an actual LVDN scenario,which demonstrates its advantages in enhancing PV accommodation capacity.In addition,the economic benefits of various planning schemes with different flexible interconnection topologies and different PV grid-connected forms are quantitatively analyzed,demonstrating the adaptability of the proposed coordinated planning method.
基金Project(N110404031)supported by the Fundamental Research Funds for the Central Universities,China
文摘With the growing deployment of smart distribution grid,it has become urgent to investigate the smart distribution grid behavior during transient faults and improve the system stability.The feasibility of segmenting large power grids and multiple smart distribution grids interconnections using energy storage technology for improving the system dynamic stability was studied.The segmentation validity of the large power grids and smart distribution grid inverter output interconnections power system using energy storage technology was proved in terms of theoretical analysis.Then,the influences of the energy storage device location and capacity on the proposed method were discussed in detail.The conclusion is obtained that the ESD optimal locations are allocated at the tie line terminal buses in the interconnected grid,respectively.The effectiveness of the proposed method was verified by simulations in an actual power system.
文摘Energy storage (ES) is a form of media that store one form of energy to be utilized at another time. Importance of ES is comprehended while intermittent nature of renewable energy (RE) generation increases and integration into the grid becomes viable in terms of economics and environment. However, technical analysis should be carried out before large scale integration into the grid. Some utilities experienced in Europe and expressed concern about issues in integrating large scale renewable energy in the areas of harmonics, voltage regulation, network protection and islanding. In Australia, distribution network (DN) is not robust compared to the European grid;moreover loads are largely distributed over large geographical areas. Installation of RE such as roof top solar photovoltaic (PV) is increasing in Australia which also boosted by the governments incentives to the individual owners. It is therefore obvious that large scale PV integration into the Australian grid is imminent. The intermittent characteristic of solar PV is expected to have greater impacts on DN in Australia compared to the DN in Europe. Therefore this paper investigated the impacts of solar PV on low voltage (LV) DN where loads connected through distribution transformer (DT) and finally further investigation was conducted with the deployment of ES into the respective load centers. It was found that storage reduced the overall peak load condition on the DT, and also reduced the energy fluctuation in the DN. It was also found that storage improved the voltage regulation on the LV side of DT and stabilized node voltage.
文摘A smart grid will require, to greater or lesser degrees, advanced tools for planning and operation, broadly accepted communications platforms, smart sensors and controls, and real-time pricing. The smart grid has been described as something of an ecosystem with constantly communication, proactive, and virtually self-aware. The use of smart grid has a lot of economical and environmental advantages;however it has a downside of instability and unpredictability introduced by distributed generation (DG) from renewable energy into the public electric systems. Variable energies such as solar and wind power have a lack of stability and to avoid short-term fluctuations in power supplied to the grid, a local storage subsystem could be used to provide higher quality and stability in the fed energy. Energy storage systems (ESSs) would be a facilitator of smart grid deployment and a “small amount” of storage would have a “great impact” on the future power grid. The smart grid, with its various superior communications and control features, would make it possible to integrate the potential application of widely dispersed battery storage systems as well other ESSs. This work deals with a detailed updated review on available ESSs applications in future smart power grids. It also highlights latest projects carried out on different ESSs throughout all around the world.
基金funded by the Gansu Provincial Science and Technology Information Disclosure System Project(21ZD8JA001)Tianyou Innovation Team of Lanzhou Jiaotong University(TY202009).
文摘To address the frequency fluctuation problem caused by the power dynamic imbalance between the power system and the loadwhen a large number of newenergy sources are connected to the grid,a two-layer fuzzy control strategy is proposed for the participation of the energy storage battery system in FM.Firstly,considering the coordination of FM units responding to automatic power generation control commands,a comprehensive allocation strategy of two signals under automatic power generation control commands is proposed to give full play to the advantages of two FM signals while enabling better coordination of two FM units responding to FM commands;secondly,based on the grid FM demand and battery FM capability,a double-layer fuzzy control strategy is proposed for FM units responding to automatic power generation control commands in a coordinated manner under dual-signal allocation mode to precisely allocate the power output depth of FM units,which can control the fluctuation of frequency deviation within a smaller range at a faster speed while maintaining the battery charge state;finally,the proposed Finally,the proposed control strategy is simulated and verified inMatlab/Simulink.The results show that the proposed control strategy can control the frequency deviation within a smaller range in a shorter time,better stabilize the fluctuation of the battery charge level,and improve the utilization of the FM unit.
基金funded by the ARC Linkage Grant LP100100618,Country Energy and the University of Wollongong
文摘This paper discusses the future power system consisting of distributed generations connected to local loads in the form of micro-grid systems.The benefits of having energy storage systems and the role of power electronics in micro-grid systems are presented.This paper also examines how micro-grids have a key role to play in the development of the smart grid.
文摘The experiment is studied on thermal distribution in the thermal energy storage system with non-phase change materials (NPCM): NaNO3, KNO3 and NaCl in the range of 25°C - 250°C. The cylindrical storage system was made of stainless steel with 25.6 cm-diameter and 26.8 cm-height that was contained of these NPCM. There was one pipe for heat transfer fluid (HTF) with 1.27 cm-diameter that manipulates in the storage tank and submerges to NPCM. The inner pipe was connected to the 2.27 cm-diameter outer HTF tube. The tube was further connected to the thermal pump, heater and load. The pump circulates the synthetic oil (Thermia oil) within the pipe for heat transferring purposes (charging and discharging). An electric heater is used as the heat source. The limitation of the charging oil temperature is maintained at 250°C with the flow rates in the range of 0.58 to 1.45 kg/s whereas the inlet temperature of the discharge oil is maintained at 25°C. Thermal performances of TES (thermal energy storage) such as charging and discharging times, radial thermal distribution, energy storage capacity and energy efficiency have been evaluated. The experimental results show that the radial thermal distribution of NaCl for TR inside, TR middle and TR outside was optimum of temperature down to NaNO3 and KNO3 respectively. Comparison of NPCMs with oil, flow rates for NaCl were charging and discharging heat transfer than KNO3 and NaNO3. The thermal stored NaCl ranged from 5712 - 5912 J;KNO3 ranged from 7350 - 7939 J and NaNO3 ranged from 6623 - 6930 J respectively. The thermal energy stored for experimental results got with along the KNO3, NaNO3 and NaCl respectively. The thermal energy efficiency of NaCl, KNO3 and NaNO3 was in the range 66% - 70%.
文摘With certain controllability of various distribution energy resources (DERs) such as battery energy storage system (BESS), demand response (DR) and distributed generations (DGs), virtual power plant (VPP) can suitably regulate the powers access to the distribution network. In this paper, an optimal VPP operating problem is used to optimize the charging/discharging schedule of each BESS and the DR scheme with the objective to maximize the benefit by regulating the supplied powers over daily 24 hours. The proposed solution method is composed of an iterative dynamic programming optimal BESS schedule approach and a particle swarm optimization based (PSO-based) DR scheme approach. The two approaches are executed alternatively until the minimum elec-tricity cost of the whole day is obtained. The validity of the proposed method was confirmed with the obviously decreased supplied powers in the peak-load hours and the largely reduced electricity cost.
基金supported by the Technical Project of the State Grid Corporation of China(research and demonstration application of key technology of energy storage cloud for mobile energy storage application of electric vehicles 5419-201971217a-0-0-00)。
文摘As part of the ongoing information revolution,smart power grid technology has become a key focus area for research into power systems.Intelligent electrical appliances are now an important component of power systems,providing a smart power grid with increased control,stability,and safety.Based on the secure communication requirements of cloud energy storage systems,this paper presents the design and development of a node controller for a cloud energy storage network.The function division and system deployment processes were carried out to ensure the security of the communication network used for the cloud energy storage system.Safety protection measures were proposed according to the demands of the communication network,allowing the system to run safely and stably.Finally,the effectiveness of the system was verified through a client-side distributed energy storage demonstration project in Suzhou,China.The system was observed to operate safely and stably,demonstrating good peak-clipping and valley filling effects,and improving the system load characteristics.
文摘Variable distributed energy resources (DERs) such as photovoltaic (PV) systems and wind power systems require additional power resources to control the balance between supply and demand. Battery energy storage systems (BESSs) are one such possible resource for providing grid stability. It has been proposed that decentralized BESSs could help support microgrids (MGs) with intelligent control when advanced functionalities are implemented with variable DERs. One key challenge is developing and testing smart inverter controls for DERs. This paper presents a standardized method to test the interoperability and functionality of BESSs. First, a survey of grid-support standards prevalent in several countries was conducted. Then, the following four interoperability functions defined in IEC TR 61850-90-7 were tested: the specified active power from storage test (INV4), the var-priority Volt/VAR test (VV) and the specified power factor test (INV3) and frequency-watt control (FW). This study then out-lines the remaining technical issues related to basic BESS smart inverter test protocols.