When multiple LCC-HVDC transmission lines are densely fed into a receiving AC system,voltage dips can easily propagate in the power system,resulting in multiple LCC commutation failures simultaneously.The VSC-HVDC can...When multiple LCC-HVDC transmission lines are densely fed into a receiving AC system,voltage dips can easily propagate in the power system,resulting in multiple LCC commutation failures simultaneously.The VSC-HVDC can be used to divide the receiving sys-tem into several interconnected sub-partitions and improve the voltage support capability of the receiving system.Compared with asyn-chronous interconnection,which completely separates the receiving systems with VSC-HVDC,incomplete segmentation with an AC connection is a more pertinent segmenting method for multilayer complex regional power grids.To analyze the voltage support capability of the VSC in incomplete segmentation,a micro-incremental model of the VSC was established,the operating impedance of the VSC was calculated,and the voltage support function of the VSC was quantified.The effect of the fault on the system short-circuit capacity was analyzed,and a calculation method for the multi-infeed short-circuit ratio in an incompletely segmented scenario was obtained.A VSC-segmented model of a two-infeed DC system was built on the EMTDC/PSCAD simulation platform,and the validity of the micro-increment model and accuracy of the proposed conclusions were verified.展开更多
Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluat...Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluate its influence on the voltage interaction between VSC-HVDC and line commutated converter based high voltage direct current(LCC-HVDC),this paper proposes a hybrid multi-infeed interaction factor(HMIIF)calculation method considering the voltage regulation control characteristics of VSC-HVDC.Firstly,for a hybrid multi-infeed high voltage direct current system,an additional equivalent operating admittance matrix is constructed to characterize HVDC equipment characteristics under small disturbance.Secondly,based on the characteristic curve between the reactive power and the voltage of a certain VSC-HVDC project,the additional equivalent operating admittance of VSC-HVDC is derived.The additional equivalent operating admittance matrix calculation method is proposed.Thirdly,the equivalent bus impedance matrix is obtained by modifying the alternating current(AC)system admittance matrix with the additional equivalent operating admittance matrix.On this basis,the HMIIF calculation method based on the equivalent bus impedance ratio is proposed.Finally,the effectiveness of the proposed method is verified in a hybrid dual-infeed high voltage direct current system constructed in Power Systems Computer Aided Design(PSCAD),and the influence of voltage regulation control on HMIIF is analyzed.展开更多
The close proximity and the necessity of coordination between multiple high-voltage direct currents(HVDCs)raise the issue of grid partitioning in multi-infeed HVDC systems.A multi-objective partition strategy is propo...The close proximity and the necessity of coordination between multiple high-voltage direct currents(HVDCs)raise the issue of grid partitioning in multi-infeed HVDC systems.A multi-objective partition strategy is proposed in this paper.Several types of relationships to be coordinated and complemented are analyzed and formulated using quantitative indices.According to the graph theory,the HVDC partition is transformed into a graph-cut problem and solved via the spectral clustering algorithm.Finally,the proposed method is validated for a practical multi-HVDC grid,confirming its feasibility and effectiveness.展开更多
In multi-infeed HVDC system, the interactions and influences between DC systems AC systems are complex as the electrical distances among DC converter stations which are relatively short. Multi-infeed interaction facto...In multi-infeed HVDC system, the interactions and influences between DC systems AC systems are complex as the electrical distances among DC converter stations which are relatively short. Multi-infeed interaction factor (MIIF) can effectively reflect the interaction among DC systems. The paper theoretically analyzes the impact factors of MIIF like the electrical distances between two DC converter stations and the equivalent impedance of the receiving end AC system. By applying the Kirchhoff’s current law on the inverter AC bus, the paper deduces the analytical expressions for MIIF. From the expression, it is clear how the equivalent impedance of AC system and coupling impedance can affect MIIF. PSCAD simulations validate the effectiveness and the correctness of the proposed expression and some useful conclusions are drawn.展开更多
An advanced nonlinear robust control scheme is proposed for multi-machine power systems equipped with thyristor-controlled series compensation (TCSC). First, a decentralized nonlinear robust control approach based on ...An advanced nonlinear robust control scheme is proposed for multi-machine power systems equipped with thyristor-controlled series compensation (TCSC). First, a decentralized nonlinear robust control approach based on the feedback linearization and H∞ theory is introduced to eliminate the nonlinearities and interconnections of the studied system, and to attenuate the exogenous disturbances that enter die system. Then, a system model is built up, which has considered all the generators’ and TCSC’s dynamics, and the effects of uncertainties such as disturbances. Next, a decentralized nonlinear robust coordinated control law is developed based on this model. Simulation results on a six-machine power system show that the transient stability of the power system is obviously improved and die power transfer capacity of long distance transmission lines is enhanced regardless of fault locations and system operation points. In addition, the control law has engineering practicality since all the variables in the expression of he control strategy can be measured locally.展开更多
Results of an investigation on the application of STATCOM for damping subsynchronous resonance (SSR) in a multi-machine system is presented in this paper. For a multi-machine system which has a set of identical parall...Results of an investigation on the application of STATCOM for damping subsynchronous resonance (SSR) in a multi-machine system is presented in this paper. For a multi-machine system which has a set of identical parallel turbine-generators or non-identical turbine-generators having torsional modes of the same frequency, generators may suffer from the same mode of torsional interaction corresponding to a certain series compensation degrees. Generators in such system may have different oscillation behaviors when they are unequally loaded or have different shaft and electrical parameters. Serving as the grid-side equipment, the reactive power output of a STATCOM could have an impact on all generators electrical distance nearby. Thus a single STATCOM could be used to damp torsional interactions of multi-generators when additional proper control strategy is supplemented. In this paper, control strategy of using STATCOM to damp SSR in a multi-machine system is designed and its effectiveness is validated based on a modified IEEE second benchmark model.展开更多
More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in o...More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in other countries. Accurate and reliable study tools and methods are extremely needed for power system engineers and researchers to deal with such problems which were never met before and otherwhere. A novel approach on electromagnetic modeling of alternating current / direct current(AC/DC) system is proposed and simulation is carried out to replay a real AC 3-phase to ground fault on a multi-infeed high voltage direct current(MIHVDC) system. AC system is specially simplified. Dynamic models and real parameters are adopted in main AC/DC equipments concerned and retained. Modeling and simulation are based on the power system computer aided design/electro-magnetic transient in direct current(PSCAD/EMTDC) system software package.Comparisons between simulation results and the records from the fault recorders are studied including both AC and DC quantities.展开更多
Multi-machine collaboration of agricultural machinery is one of the international frontier and hot research in the field of agricultural equipment.However,the current domestic multi-machine collaborative operation of ...Multi-machine collaboration of agricultural machinery is one of the international frontier and hot research in the field of agricultural equipment.However,the current domestic multi-machine collaborative operation of agricultural machinery is limited to the research of task goal planning and collaborative path optimization in a single production link.In order to achieve the purpose of zero inventory of agricultural materials and precise and efficient production operations,a new technology of agricultural machinery multi-machine collaboration with multi-dimension and full chain was proposed,which takes into account the whole process of agricultural production,as well as agricultural machinery system and external supply chain,storage and transportation chain collaboration.The problems of data collaboration,process collaboration and organization collaboration were analyzed.And the realization conditions of new multi-machine cooperative technology were analyzed.Meanwhile,the zero inventory mode and precise operation mode of agricultural materials under the background of multi-machine cooperation of intelligent agricultural machinery were studied.Then,a precise and efficient agricultural production mode based on data-process-organization collaboration was constructed.The results showed that the multi-machine cooperative technology mode of multi-dimensional and full-chain agricultural machinery could greatly improve the efficiency of agricultural machinery,operation quality,land utilization rate and reduce production cost.展开更多
Battery pack capacity estimation under real-world operating conditions is important for battery performance optimization and health management,contributing to the reliability and longevity of batterypowered systems.Ho...Battery pack capacity estimation under real-world operating conditions is important for battery performance optimization and health management,contributing to the reliability and longevity of batterypowered systems.However,complex operating conditions,coupling cell-to-cell inconsistency,and limited labeled data pose great challenges to accurate and robust battery pack capacity estimation.To address these issues,this paper proposes a hierarchical data-driven framework aimed at enhancing the training of machine learning models with fewer labeled data.Unlike traditional data-driven methods that lack interpretability,the hierarchical data-driven framework unveils the“mechanism”of the black box inside the data-driven framework by splitting the final estimation target into cell-level and pack-level intermediate targets.A generalized feature matrix is devised without requiring all cell voltages,significantly reducing the computational cost and memory resources.The generated intermediate target labels and the corresponding features are hierarchically employed to enhance the training of two machine learning models,effectively alleviating the difficulty of learning the relationship from all features due to fewer labeled data and addressing the dilemma of requiring extensive labeled data for accurate estimation.Using only 10%of degradation data,the proposed framework outperforms the state-of-the-art battery pack capacity estimation methods,achieving mean absolute percentage errors of 0.608%,0.601%,and 1.128%for three battery packs whose degradation load profiles represent real-world operating conditions.Its high accuracy,adaptability,and robustness indicate the potential in different application scenarios,which is promising for reducing laborious and expensive aging experiments at the pack level and facilitating the development of battery technology.展开更多
This paper provides a comprehensive analysis of local and concurrent commutation failure(CF)of multi-infeed high-voltage direct current(HVDC)system considering multi-infeed interaction factor(MIIF).The literature indi...This paper provides a comprehensive analysis of local and concurrent commutation failure(CF)of multi-infeed high-voltage direct current(HVDC)system considering multi-infeed interaction factor(MIIF).The literature indicates that the local CF is not influenced by MIIF,whereas this paper concludes that both the local CF and concurrent CF are influenced by MIIF.The ability of remote converter to work under reduced reactive power enables its feature to support local converter via inter-connection link.The MIIF measures the strength of electrical connectivity between converters.Higher MIIF gives a clearer path to remote converter to support local converter,but at the same time,it provides an easy path to local converter to disturb remote converter under local fault.The presence of nearby converter increases the local commutation failure immunity index(CFII)while reducing concurrent CFII.Higher MIIF causes reactive power support to flow from remote converter to local converter,which reduces the chances of CF.A mathematical approximation to calculate the increase in local CFII for multi-infeed HVDC configurations is also proposed.A power flow approach is used to model the relation between MIIF and reactive power support from remote end.The local and concurrent CFIIs are found to be inverse to each other over MIIF;therefore,it is recommended that there is an optimal value of MIIF for all converters in close electric proximity to maintain CFII at a certain level.The numerical results of established model are compared with PSCAD/EMTDC simulations.The simulation results show the details of the influence of MIIF on local CF and concurrent CF of multi-infeed HVDC,which validates the analysis presented.展开更多
High-voltage direct current(HVDC)transmission is playing an increasingly important role in modern power systems,and the resulted power/voltage stability issue has raised widespread concern.This paper presents an on-li...High-voltage direct current(HVDC)transmission is playing an increasingly important role in modern power systems,and the resulted power/voltage stability issue has raised widespread concern.This paper presents an on-line power/voltage stability index(PVSI)for multi-infeed HVDC(MIDC)systems.Different from the existing indices which are developed mainly for off-line and static analysis,the proposed PVSI can be applied in real time.Effects of system changes on stability assessment such as change of system states and control strategies are considered.Thus,helpful guidance can be provided for on-line HVDC stability and controls.The PVSI is originally deduced for single-infeed HVDC systems in an‘‘AC way’’by analyzing the power and voltage stability of both pure AC systems and HVDC systems.Moreover,its on-line application in practical MIDC systems is realized by building an equivalent single-infeed model,and utilizing nowadays measurement and communication infrastructures such as wide-area measurement system(WAMS).The effectiveness of the PVSI is verified through simulations in real-time digital simulator(RTDS).展开更多
In China,the primary energy bases and the energyrequirement areas are mismatched,which presents theremote and reverse distribution characteristics,and thelarge-scale power flow is from the west to the cast andfrom the...In China,the primary energy bases and the energyrequirement areas are mismatched,which presents theremote and reverse distribution characteristics,and thelarge-scale power flow is from the west to the cast andfrom the north to the south.In this paper,according tothe above characteristics and the power flow pattern,thelarge-scale,high-efficiency and long-distance UHVACand UHVDC combined transmission scheme is investi-gated and proposed,and the development mode ofChina's power grid and the planning scheme of‘NorthChina-Central China-East China'synchronous UHV gridwhich can satisfy the healthy and sustainabledevelopment of China's economy and society is proposedand optimized.展开更多
This paper proposes a coordinated switching power system stabilizer(SPSS)to enhance the stability of multimachine power systems.The SPSS switches between a bang-bang power system stabilizer(BPSS)and a conventional pow...This paper proposes a coordinated switching power system stabilizer(SPSS)to enhance the stability of multimachine power systems.The SPSS switches between a bang-bang power system stabilizer(BPSS)and a conventional power system stabilizer(CPSS)based on a state-dependent switching strategy.The BPSS is designed as a bang-bang constant funnel controller(BCFC).It is able to provide fast damping of rotor speed oscillations in a bang-bang manner.The closed-loop stability of the power system controlled by the SPSSs and the CPSSs is analyzed.To verify the control performance of the SPSS,simulation studies are carried out in a 4-generator 11-bus power system and the IEEE 16-generator 68-bus power system.The damping ability of the SPSS is evaluated in aspects of small-signal oscillation damping and transient stability enhancement,respectively.Meanwhile,the coordination between different SPSSs and the coordination between the SPSS and the CPSS are investigated therein.展开更多
This paper proposes a novel framework that enables the simultaneous coordination of the controllers of doubly fed induction generators(DFIGs) and synchronous generators(SGs).The proposed coordination approach is based...This paper proposes a novel framework that enables the simultaneous coordination of the controllers of doubly fed induction generators(DFIGs) and synchronous generators(SGs).The proposed coordination approach is based on the zero dynamics method aims at enhancing the transient stability of multi-machine power systems under a wide range of operating conditions. The proposed approach was implemented to the IEEE39-bus power systems. Transient stability margin measured in terms of critical clearing time along with eigenvalue analysis and time domain simulations were considered in the performance assessment. The obtained results were also compared to those achieved using a conventional power system stabilizer/power oscillation(PSS/POD) technique and the interconnection and damping assignment passivity-based controller(IDA-PBC). The performance analysis confirmed the ability of the proposed approach to enhance damping and improve system’s transient stability margin under a wide range of operating conditions.展开更多
This paper presented a novel wide-area nonlinear excitation control strategy for multi-machine power systems. A simple and effective model transformation method was proposed for the system's mathematical model in ...This paper presented a novel wide-area nonlinear excitation control strategy for multi-machine power systems. A simple and effective model transformation method was proposed for the system's mathematical model in the COI (center of inertia) coordinate system. The system was transformed to an uncertain linear one where deviation of generator terminal voltage became one of the new state variables. Then a wide-area nonlinear robust voltage controller was designed utilizing a LMI (linear matrix inequality) based robust control theory. The proposed controller does not rely on any preselected system operating point, adapts to variations of network parameters and system operation conditions, and assures regulation accuracy of generator terminal voltages. Neither rotor angle nor any variable's differentiation needs to be measured for the proposed controller, and only terminal voltages, rotor speeds, active and reactive power outputs of generators are required. In addition, the proposed controller not only takes into account time delays of remote signals, but also eliminates the effect of wide-area information's incompleteness when not all generators are equipped with PMU (phase measurement unit). Detailed tests were conducted by PSCAD/EMTDC for a three-machine and four-machine power systems respectively, and simulation results illustrate high performance of the proposed controller.展开更多
The Brazilian transmission system is facing challenging problems with the distance between its generation areas and consumer centers that will be partly solved by the use of HVDC point-to-point systems.In the near fut...The Brazilian transmission system is facing challenging problems with the distance between its generation areas and consumer centers that will be partly solved by the use of HVDC point-to-point systems.In the near future,the southeast subsystem will have a large amount of power injected through HVDC Systems in multiple points with relatively close electrical proximity.Therefore,the effects of a multi-infeed system are expected to influence the performance and operation of the network.Extensive studies and simulations will play an important role in determining the extension of the interactions among HVDC converters and determine if such interactions cause multiple commutation failures,thus disturbing the dynamic stability of the system.The use of CCC(Capacitor Commutated Converter)HVDC systems will also be assessed and is expected to diminish the need for a strong AC network(high short circuit level)and,therefore,mitigate multi-infeed interactions.The southeast subsystem of the Brazilian Power System currently has four LCC inverters,two of them belong to the Madeira power plant and the other two are from the Itaipu power plant.By the year 2024,four other HVDC systems will be arriving in the same region.This paper discusses the HVDC multi-infeed phenomena regarding the relevance of using synchronous machine models to represent important power plants and the application of mitigation methods regarding the 2020 network model,where six HVDC links will be present.展开更多
This paper proposes a switching structure excitation controller(SSEC)to enhance the transient stability of multimachine power systems.The SSEC switches between a bangbang funnel excitation controller(BFEC)and a conven...This paper proposes a switching structure excitation controller(SSEC)to enhance the transient stability of multimachine power systems.The SSEC switches between a bangbang funnel excitation controller(BFEC)and a conventional excitation controller(CEC),based on an appropriately designed state-dependent switching strategy.Only the tracking error of rotor angle is required to realize the BFEC in a bang-bang manner with two control values.If the feasibility assumptions of the BFEC are satisfied,the tracking error of rotor angle can be regulated within the predefined error funnels.The power system having the SSEC installed can achieve faster convergence performance compared to that having the CEC implemented only.Simulation studies are carried out in the New England 10-generator 39-bus power system.The control performance of the SSEC is evaluated in the cases that three-phase-to-ground fault and transmission line outage occur in the power system,respectively.展开更多
Power system stability is enhanced through a novel stabilizer developed around an adaptive fuzzy sliding mode approach which applies the Nussbaum gain to a nonlinear model of a single-machine infinite-bus (SMIB) and...Power system stability is enhanced through a novel stabilizer developed around an adaptive fuzzy sliding mode approach which applies the Nussbaum gain to a nonlinear model of a single-machine infinite-bus (SMIB) and multi-machine power system stabilizer subjected to a three phase fault. The Nussbaum gain is used to avoid the positive sign constraint and the problem of controllability of the system. A comparative simulation study is presented to evaluate the achieved performance.展开更多
For the hybrid multi-infeed HVDC system in which the receiving-end grid is a strong AC grid including LCC-HVDC subsystems and multiple VSC-HVDC subsystems,it has higher voltage support capability.However,for weak AC g...For the hybrid multi-infeed HVDC system in which the receiving-end grid is a strong AC grid including LCC-HVDC subsystems and multiple VSC-HVDC subsystems,it has higher voltage support capability.However,for weak AC grid,the voltage support capability of the multi-VSC-HVDC subsystems to the LCC-HVDC subsystem(voltage support capability-mVSCs-LCC)can resist the risk of commutation failure.Based on this consideration,this paper proposes an evaluation index called Dynamic Voltage Support Strength Factor(DVSF)for the hybrid multi-infeed system,and uses this index to qualitatively judge the voltage support capability-mVSCs-LCC in weak AC grid.In addition,the proposed evaluation index can also indirectly judge the ability of the LCC-HVDC subsystem to suppress commutation failure.Firstly,the mathematical model of the power flow of the LCC and VSC networks in the steady-state is analyzed,and the concept of DVSF applied to hybrid multi-infeed system is proposed.Furthermore,the DVSF index is also used to qualitatively judge the voltage support capability-mVSCs-LCC.Secondly,the influence of multiple VSC-HVDC subsystems with different operation strategies on the DVSF is analyzed with reference to the concept of DVSF.Finally,the indicators proposed in this paper are compared with other evaluation indicators through MATLAB simulation software to verify its effectiveness.More importantly,the effects of multi-VSC-HVDC subsystems using different coordinated control strategies on the voltage support capability of the receiving-end LCC-HVDC subsystem are also verified.展开更多
In previous papers,the authors presented various electromagnetic transient(EMT)results for multi-infeed configurations focusing on possible effects from failures in one link being transferred to others in terms of ind...In previous papers,the authors presented various electromagnetic transient(EMT)results for multi-infeed configurations focusing on possible effects from failures in one link being transferred to others in terms of induced commutation failures(CF),either during the fault events or after fault clearing in the recovery period.However,the AC system networks in these cases were represented by simplified equivalents.Many interesting conclusions arose from these publications without enabling a much-detailed analysis of overall system effects,which is only possible when the network is modeled in full detail.This paper aims at complementing and comparing simulation results on HVDC multi-infeed configurations using both dynamic stability and electromagnetic transient,while establishing some basic proposals for optimal use of both tools.It identifies the limitations from each type of study so that a comprehensive and useful analysis of HVDC multi-infeed systems can be obtained.展开更多
基金supported by the State Grid Science and Technology Project 5108-202218280A-2-87-XG.
文摘When multiple LCC-HVDC transmission lines are densely fed into a receiving AC system,voltage dips can easily propagate in the power system,resulting in multiple LCC commutation failures simultaneously.The VSC-HVDC can be used to divide the receiving sys-tem into several interconnected sub-partitions and improve the voltage support capability of the receiving system.Compared with asyn-chronous interconnection,which completely separates the receiving systems with VSC-HVDC,incomplete segmentation with an AC connection is a more pertinent segmenting method for multilayer complex regional power grids.To analyze the voltage support capability of the VSC in incomplete segmentation,a micro-incremental model of the VSC was established,the operating impedance of the VSC was calculated,and the voltage support function of the VSC was quantified.The effect of the fault on the system short-circuit capacity was analyzed,and a calculation method for the multi-infeed short-circuit ratio in an incompletely segmented scenario was obtained.A VSC-segmented model of a two-infeed DC system was built on the EMTDC/PSCAD simulation platform,and the validity of the micro-increment model and accuracy of the proposed conclusions were verified.
基金supported by the Technology Project of the State Grid Corporation Headquarters Management(Contract No.5100-202158467A-0-0-00).
文摘Voltage source converter based high voltage direct current(VSC-HVDC)can participate in voltage regulation by flexible control to help maintain the voltage stability of the power grid.In order to quantitatively evaluate its influence on the voltage interaction between VSC-HVDC and line commutated converter based high voltage direct current(LCC-HVDC),this paper proposes a hybrid multi-infeed interaction factor(HMIIF)calculation method considering the voltage regulation control characteristics of VSC-HVDC.Firstly,for a hybrid multi-infeed high voltage direct current system,an additional equivalent operating admittance matrix is constructed to characterize HVDC equipment characteristics under small disturbance.Secondly,based on the characteristic curve between the reactive power and the voltage of a certain VSC-HVDC project,the additional equivalent operating admittance of VSC-HVDC is derived.The additional equivalent operating admittance matrix calculation method is proposed.Thirdly,the equivalent bus impedance matrix is obtained by modifying the alternating current(AC)system admittance matrix with the additional equivalent operating admittance matrix.On this basis,the HMIIF calculation method based on the equivalent bus impedance ratio is proposed.Finally,the effectiveness of the proposed method is verified in a hybrid dual-infeed high voltage direct current system constructed in Power Systems Computer Aided Design(PSCAD),and the influence of voltage regulation control on HMIIF is analyzed.
基金supported by the Science and Technology Project of State Grid Corporation of China:“Control Strategy Optimization Technology for Large-Scale Photovoltaic Power Generation on the Sending-end and Receiving-end of DC Power System”(4000-201934198A-0-0-00)
文摘The close proximity and the necessity of coordination between multiple high-voltage direct currents(HVDCs)raise the issue of grid partitioning in multi-infeed HVDC systems.A multi-objective partition strategy is proposed in this paper.Several types of relationships to be coordinated and complemented are analyzed and formulated using quantitative indices.According to the graph theory,the HVDC partition is transformed into a graph-cut problem and solved via the spectral clustering algorithm.Finally,the proposed method is validated for a practical multi-HVDC grid,confirming its feasibility and effectiveness.
文摘In multi-infeed HVDC system, the interactions and influences between DC systems AC systems are complex as the electrical distances among DC converter stations which are relatively short. Multi-infeed interaction factor (MIIF) can effectively reflect the interaction among DC systems. The paper theoretically analyzes the impact factors of MIIF like the electrical distances between two DC converter stations and the equivalent impedance of the receiving end AC system. By applying the Kirchhoff’s current law on the inverter AC bus, the paper deduces the analytical expressions for MIIF. From the expression, it is clear how the equivalent impedance of AC system and coupling impedance can affect MIIF. PSCAD simulations validate the effectiveness and the correctness of the proposed expression and some useful conclusions are drawn.
基金This work was supported by Chinese National Natural Science Foundation(No.50377018)Chinese National Key Basic Research Fund(No.G1998020309)by New Energy and Industrial Technology Development Organization of Japan.
文摘An advanced nonlinear robust control scheme is proposed for multi-machine power systems equipped with thyristor-controlled series compensation (TCSC). First, a decentralized nonlinear robust control approach based on the feedback linearization and H∞ theory is introduced to eliminate the nonlinearities and interconnections of the studied system, and to attenuate the exogenous disturbances that enter die system. Then, a system model is built up, which has considered all the generators’ and TCSC’s dynamics, and the effects of uncertainties such as disturbances. Next, a decentralized nonlinear robust coordinated control law is developed based on this model. Simulation results on a six-machine power system show that the transient stability of the power system is obviously improved and die power transfer capacity of long distance transmission lines is enhanced regardless of fault locations and system operation points. In addition, the control law has engineering practicality since all the variables in the expression of he control strategy can be measured locally.
文摘Results of an investigation on the application of STATCOM for damping subsynchronous resonance (SSR) in a multi-machine system is presented in this paper. For a multi-machine system which has a set of identical parallel turbine-generators or non-identical turbine-generators having torsional modes of the same frequency, generators may suffer from the same mode of torsional interaction corresponding to a certain series compensation degrees. Generators in such system may have different oscillation behaviors when they are unequally loaded or have different shaft and electrical parameters. Serving as the grid-side equipment, the reactive power output of a STATCOM could have an impact on all generators electrical distance nearby. Thus a single STATCOM could be used to damp torsional interactions of multi-generators when additional proper control strategy is supplemented. In this paper, control strategy of using STATCOM to damp SSR in a multi-machine system is designed and its effectiveness is validated based on a modified IEEE second benchmark model.
文摘More and more high voltage direct current(HVDC) converters are being located in a load area in the Yangtze River Delta Region in China. It's large transmission capacity and intensive placement are hardly seen in other countries. Accurate and reliable study tools and methods are extremely needed for power system engineers and researchers to deal with such problems which were never met before and otherwhere. A novel approach on electromagnetic modeling of alternating current / direct current(AC/DC) system is proposed and simulation is carried out to replay a real AC 3-phase to ground fault on a multi-infeed high voltage direct current(MIHVDC) system. AC system is specially simplified. Dynamic models and real parameters are adopted in main AC/DC equipments concerned and retained. Modeling and simulation are based on the power system computer aided design/electro-magnetic transient in direct current(PSCAD/EMTDC) system software package.Comparisons between simulation results and the records from the fault recorders are studied including both AC and DC quantities.
基金financially supported by Major Science and Technology Projects in Xinjiang Autonomous Region(Grant No.2022A02005-5)the National Natural Science Foundation of China(Grant No.32071905)the Priority Academic Program Development of Jiangsu Higher Education Institutions(Grant No.PAPD-2023-87).
文摘Multi-machine collaboration of agricultural machinery is one of the international frontier and hot research in the field of agricultural equipment.However,the current domestic multi-machine collaborative operation of agricultural machinery is limited to the research of task goal planning and collaborative path optimization in a single production link.In order to achieve the purpose of zero inventory of agricultural materials and precise and efficient production operations,a new technology of agricultural machinery multi-machine collaboration with multi-dimension and full chain was proposed,which takes into account the whole process of agricultural production,as well as agricultural machinery system and external supply chain,storage and transportation chain collaboration.The problems of data collaboration,process collaboration and organization collaboration were analyzed.And the realization conditions of new multi-machine cooperative technology were analyzed.Meanwhile,the zero inventory mode and precise operation mode of agricultural materials under the background of multi-machine cooperation of intelligent agricultural machinery were studied.Then,a precise and efficient agricultural production mode based on data-process-organization collaboration was constructed.The results showed that the multi-machine cooperative technology mode of multi-dimensional and full-chain agricultural machinery could greatly improve the efficiency of agricultural machinery,operation quality,land utilization rate and reduce production cost.
基金supported by the National Outstanding Youth Science Fund Project of National Natural Science Foundation of China[Grant No.52222708]the Natural Science Foundation of Beijing Municipality[Grant No.3212033]。
文摘Battery pack capacity estimation under real-world operating conditions is important for battery performance optimization and health management,contributing to the reliability and longevity of batterypowered systems.However,complex operating conditions,coupling cell-to-cell inconsistency,and limited labeled data pose great challenges to accurate and robust battery pack capacity estimation.To address these issues,this paper proposes a hierarchical data-driven framework aimed at enhancing the training of machine learning models with fewer labeled data.Unlike traditional data-driven methods that lack interpretability,the hierarchical data-driven framework unveils the“mechanism”of the black box inside the data-driven framework by splitting the final estimation target into cell-level and pack-level intermediate targets.A generalized feature matrix is devised without requiring all cell voltages,significantly reducing the computational cost and memory resources.The generated intermediate target labels and the corresponding features are hierarchically employed to enhance the training of two machine learning models,effectively alleviating the difficulty of learning the relationship from all features due to fewer labeled data and addressing the dilemma of requiring extensive labeled data for accurate estimation.Using only 10%of degradation data,the proposed framework outperforms the state-of-the-art battery pack capacity estimation methods,achieving mean absolute percentage errors of 0.608%,0.601%,and 1.128%for three battery packs whose degradation load profiles represent real-world operating conditions.Its high accuracy,adaptability,and robustness indicate the potential in different application scenarios,which is promising for reducing laborious and expensive aging experiments at the pack level and facilitating the development of battery technology.
基金This work was supported by science and technology project of China Southern Power Grid(No.ZBKJXM20180104).
文摘This paper provides a comprehensive analysis of local and concurrent commutation failure(CF)of multi-infeed high-voltage direct current(HVDC)system considering multi-infeed interaction factor(MIIF).The literature indicates that the local CF is not influenced by MIIF,whereas this paper concludes that both the local CF and concurrent CF are influenced by MIIF.The ability of remote converter to work under reduced reactive power enables its feature to support local converter via inter-connection link.The MIIF measures the strength of electrical connectivity between converters.Higher MIIF gives a clearer path to remote converter to support local converter,but at the same time,it provides an easy path to local converter to disturb remote converter under local fault.The presence of nearby converter increases the local commutation failure immunity index(CFII)while reducing concurrent CFII.Higher MIIF causes reactive power support to flow from remote converter to local converter,which reduces the chances of CF.A mathematical approximation to calculate the increase in local CFII for multi-infeed HVDC configurations is also proposed.A power flow approach is used to model the relation between MIIF and reactive power support from remote end.The local and concurrent CFIIs are found to be inverse to each other over MIIF;therefore,it is recommended that there is an optimal value of MIIF for all converters in close electric proximity to maintain CFII at a certain level.The numerical results of established model are compared with PSCAD/EMTDC simulations.The simulation results show the details of the influence of MIIF on local CF and concurrent CF of multi-infeed HVDC,which validates the analysis presented.
基金supported in part by the National Key Research and Development Program of China(No.2016YFB0900100)part by the National Natural Science Foundation of China(No.51577136)part by the Natural Science Foundation of Hubei Province,China(No.2018CFA080).
文摘High-voltage direct current(HVDC)transmission is playing an increasingly important role in modern power systems,and the resulted power/voltage stability issue has raised widespread concern.This paper presents an on-line power/voltage stability index(PVSI)for multi-infeed HVDC(MIDC)systems.Different from the existing indices which are developed mainly for off-line and static analysis,the proposed PVSI can be applied in real time.Effects of system changes on stability assessment such as change of system states and control strategies are considered.Thus,helpful guidance can be provided for on-line HVDC stability and controls.The PVSI is originally deduced for single-infeed HVDC systems in an‘‘AC way’’by analyzing the power and voltage stability of both pure AC systems and HVDC systems.Moreover,its on-line application in practical MIDC systems is realized by building an equivalent single-infeed model,and utilizing nowadays measurement and communication infrastructures such as wide-area measurement system(WAMS).The effectiveness of the PVSI is verified through simulations in real-time digital simulator(RTDS).
文摘In China,the primary energy bases and the energyrequirement areas are mismatched,which presents theremote and reverse distribution characteristics,and thelarge-scale power flow is from the west to the cast andfrom the north to the south.In this paper,according tothe above characteristics and the power flow pattern,thelarge-scale,high-efficiency and long-distance UHVACand UHVDC combined transmission scheme is investi-gated and proposed,and the development mode ofChina's power grid and the planning scheme of‘NorthChina-Central China-East China'synchronous UHV gridwhich can satisfy the healthy and sustainabledevelopment of China's economy and society is proposedand optimized.
基金funded by State Key Program of National Natural Science of China(No.51437006)Guangdong Innovative Research Team Program(No.201001N0104744201),China.
文摘This paper proposes a coordinated switching power system stabilizer(SPSS)to enhance the stability of multimachine power systems.The SPSS switches between a bang-bang power system stabilizer(BPSS)and a conventional power system stabilizer(CPSS)based on a state-dependent switching strategy.The BPSS is designed as a bang-bang constant funnel controller(BCFC).It is able to provide fast damping of rotor speed oscillations in a bang-bang manner.The closed-loop stability of the power system controlled by the SPSSs and the CPSSs is analyzed.To verify the control performance of the SPSS,simulation studies are carried out in a 4-generator 11-bus power system and the IEEE 16-generator 68-bus power system.The damping ability of the SPSS is evaluated in aspects of small-signal oscillation damping and transient stability enhancement,respectively.Meanwhile,the coordination between different SPSSs and the coordination between the SPSS and the CPSS are investigated therein.
文摘This paper proposes a novel framework that enables the simultaneous coordination of the controllers of doubly fed induction generators(DFIGs) and synchronous generators(SGs).The proposed coordination approach is based on the zero dynamics method aims at enhancing the transient stability of multi-machine power systems under a wide range of operating conditions. The proposed approach was implemented to the IEEE39-bus power systems. Transient stability margin measured in terms of critical clearing time along with eigenvalue analysis and time domain simulations were considered in the performance assessment. The obtained results were also compared to those achieved using a conventional power system stabilizer/power oscillation(PSS/POD) technique and the interconnection and damping assignment passivity-based controller(IDA-PBC). The performance analysis confirmed the ability of the proposed approach to enhance damping and improve system’s transient stability margin under a wide range of operating conditions.
文摘This paper presented a novel wide-area nonlinear excitation control strategy for multi-machine power systems. A simple and effective model transformation method was proposed for the system's mathematical model in the COI (center of inertia) coordinate system. The system was transformed to an uncertain linear one where deviation of generator terminal voltage became one of the new state variables. Then a wide-area nonlinear robust voltage controller was designed utilizing a LMI (linear matrix inequality) based robust control theory. The proposed controller does not rely on any preselected system operating point, adapts to variations of network parameters and system operation conditions, and assures regulation accuracy of generator terminal voltages. Neither rotor angle nor any variable's differentiation needs to be measured for the proposed controller, and only terminal voltages, rotor speeds, active and reactive power outputs of generators are required. In addition, the proposed controller not only takes into account time delays of remote signals, but also eliminates the effect of wide-area information's incompleteness when not all generators are equipped with PMU (phase measurement unit). Detailed tests were conducted by PSCAD/EMTDC for a three-machine and four-machine power systems respectively, and simulation results illustrate high performance of the proposed controller.
基金This research was supported by ANEEL(Brazilian Energy Regulatory Agency)and the State Grid Brazilian Holding,as well as the University of Sao Paulo.
文摘The Brazilian transmission system is facing challenging problems with the distance between its generation areas and consumer centers that will be partly solved by the use of HVDC point-to-point systems.In the near future,the southeast subsystem will have a large amount of power injected through HVDC Systems in multiple points with relatively close electrical proximity.Therefore,the effects of a multi-infeed system are expected to influence the performance and operation of the network.Extensive studies and simulations will play an important role in determining the extension of the interactions among HVDC converters and determine if such interactions cause multiple commutation failures,thus disturbing the dynamic stability of the system.The use of CCC(Capacitor Commutated Converter)HVDC systems will also be assessed and is expected to diminish the need for a strong AC network(high short circuit level)and,therefore,mitigate multi-infeed interactions.The southeast subsystem of the Brazilian Power System currently has four LCC inverters,two of them belong to the Madeira power plant and the other two are from the Itaipu power plant.By the year 2024,four other HVDC systems will be arriving in the same region.This paper discusses the HVDC multi-infeed phenomena regarding the relevance of using synchronous machine models to represent important power plants and the application of mitigation methods regarding the 2020 network model,where six HVDC links will be present.
基金funded by State Key Program of National Natural Science of China(NO.51437006)Guangdong Innovative Research Team Program(NO.201001N0104744201),China。
文摘This paper proposes a switching structure excitation controller(SSEC)to enhance the transient stability of multimachine power systems.The SSEC switches between a bangbang funnel excitation controller(BFEC)and a conventional excitation controller(CEC),based on an appropriately designed state-dependent switching strategy.Only the tracking error of rotor angle is required to realize the BFEC in a bang-bang manner with two control values.If the feasibility assumptions of the BFEC are satisfied,the tracking error of rotor angle can be regulated within the predefined error funnels.The power system having the SSEC installed can achieve faster convergence performance compared to that having the CEC implemented only.Simulation studies are carried out in the New England 10-generator 39-bus power system.The control performance of the SSEC is evaluated in the cases that three-phase-to-ground fault and transmission line outage occur in the power system,respectively.
文摘Power system stability is enhanced through a novel stabilizer developed around an adaptive fuzzy sliding mode approach which applies the Nussbaum gain to a nonlinear model of a single-machine infinite-bus (SMIB) and multi-machine power system stabilizer subjected to a three phase fault. The Nussbaum gain is used to avoid the positive sign constraint and the problem of controllability of the system. A comparative simulation study is presented to evaluate the achieved performance.
基金supported by the National Natural Science Foundation of China-State Grid Joint Fund for Smart Grid(No.U2066210).
文摘For the hybrid multi-infeed HVDC system in which the receiving-end grid is a strong AC grid including LCC-HVDC subsystems and multiple VSC-HVDC subsystems,it has higher voltage support capability.However,for weak AC grid,the voltage support capability of the multi-VSC-HVDC subsystems to the LCC-HVDC subsystem(voltage support capability-mVSCs-LCC)can resist the risk of commutation failure.Based on this consideration,this paper proposes an evaluation index called Dynamic Voltage Support Strength Factor(DVSF)for the hybrid multi-infeed system,and uses this index to qualitatively judge the voltage support capability-mVSCs-LCC in weak AC grid.In addition,the proposed evaluation index can also indirectly judge the ability of the LCC-HVDC subsystem to suppress commutation failure.Firstly,the mathematical model of the power flow of the LCC and VSC networks in the steady-state is analyzed,and the concept of DVSF applied to hybrid multi-infeed system is proposed.Furthermore,the DVSF index is also used to qualitatively judge the voltage support capability-mVSCs-LCC.Secondly,the influence of multiple VSC-HVDC subsystems with different operation strategies on the DVSF is analyzed with reference to the concept of DVSF.Finally,the indicators proposed in this paper are compared with other evaluation indicators through MATLAB simulation software to verify its effectiveness.More importantly,the effects of multi-VSC-HVDC subsystems using different coordinated control strategies on the voltage support capability of the receiving-end LCC-HVDC subsystem are also verified.
文摘In previous papers,the authors presented various electromagnetic transient(EMT)results for multi-infeed configurations focusing on possible effects from failures in one link being transferred to others in terms of induced commutation failures(CF),either during the fault events or after fault clearing in the recovery period.However,the AC system networks in these cases were represented by simplified equivalents.Many interesting conclusions arose from these publications without enabling a much-detailed analysis of overall system effects,which is only possible when the network is modeled in full detail.This paper aims at complementing and comparing simulation results on HVDC multi-infeed configurations using both dynamic stability and electromagnetic transient,while establishing some basic proposals for optimal use of both tools.It identifies the limitations from each type of study so that a comprehensive and useful analysis of HVDC multi-infeed systems can be obtained.