We present an experimental study on tilt-tip(TT) and phase-locking(PL) control in a coherent beam combination(CBC) system of adaptive fiber laser array.The TT control is performed using the adaptive fiber-optics...We present an experimental study on tilt-tip(TT) and phase-locking(PL) control in a coherent beam combination(CBC) system of adaptive fiber laser array.The TT control is performed using the adaptive fiber-optics collimator(AFOC),and the PL control is realized by the phase modulator(PM).Cascaded and simultaneous controls of TT and PL using stochastic parallel gradient descent(SPGD) algorithm are investigated in this paper.Two-fiber-laser-,four-fiber-laser-,and six-fiber-laser-arrays are employed to study the TT and PL control.In the cascaded control system,only one high-speed CMOS camera is used to collect beam data and a computer is used as the controller.In a simultaneous control system one high-speed CMOS camera and one photonic detector(PD) are employed,and a computer and a control circuit based on field programmable gate array(FPGA) are used as the controllers.Experimental results reveal that both cascaded and simultaneous controls of TT using AFOC and PL using PM in fiber laser array are feasible and effective.Cascaded control is more effective in static control situation and simultaneous control can be applied to the dynamic control system directly.The control signals of simultaneous PL and TT disturb each other obviously and TT and PL control may compete with each other,so the control effect is limited.展开更多
The phase and frequency locking of microwave, millimeter wave power combining were analysed and summarized in an all-round way. The master/slave phase locking of cavity oscillators, the peer phase locking of mutually ...The phase and frequency locking of microwave, millimeter wave power combining were analysed and summarized in an all-round way. The master/slave phase locking of cavity oscillators, the peer phase locking of mutually coupled oscillators, and the peer phase locking of ring-connected multiple oscillators were investigated. The results of numerical calculations, and the relations of phase to phase locking model and oscillator parameters were given. And the cavity and space power combining aspects for microwave and millimeter wave were presented.展开更多
A microwave power-combining system composed of two Panasonic 2M244-M1 magnetrons based on master–slave injection-locking is demonstrated in this paper. The principle of master–slave injection-locking and the locking...A microwave power-combining system composed of two Panasonic 2M244-M1 magnetrons based on master–slave injection-locking is demonstrated in this paper. The principle of master–slave injection-locking and the locking condition are theoretical analyzed. Experimental results are consistent with the theoretical analysis and the experimental combined efficiency is higher than 96%. Compared with the external-injection-locked system, the power-combining based on the master–slave injection-locking magnetron is superior by taking out the external solid-state driver and the real-time phase control system. Thus, this power-combining system has great potential for obtaining a high efficiency, high stability, low cost, and high power microwave source.展开更多
Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphaticall...Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphatically observing fracture healing and shoulder joint function.Methods:Totally 44 elderly patients with Robinson type 2B displaced midshaft clavicle fractures were included from the Department of Orthopaedics,Shenyang Fourth People's Hospital during February 2016 and December 2018,including 23 males and 21 females,mean age(69.8±10.2)years old.The patients were divided into a bridge combined internal fixation system group(bridge group,n=22)and a locking compression plate internal fixation group(plate group,n=22)according to the internal fixation methods.The operation time,intraoperative blood loss,fracture healing time,and postoperative complications were recorded.At 12 months after surgery,the shoulder joint Constant-Murley score and DASH score were used to assess the recovery of joint function.The serum levels of bone turnover biochemical markers procollagen I N-terminal peptide(P1NP),cross-linked Carboxy-terminal telopeptide of typeⅠcollagen(CTX-I),and osteoblast specific factor(OSF)were measured before and 3 months after surgery.Results:The operation time,intraoperative blood loss and fracture healing time of the bridge group were significantly shorter than those of the plate group(P<0.05).Constant scores and DASH scores in the bridge group were significantly better than those of the plate group at 12 months after surgery(P<0.05).Serum levels of CTX-I was significantly decreased,while the P1NP and OSF were significantly increased compared with before surgery in the both groups(P<0.05),and the changes were more obvious in the bridge group(P<0.05).The incidence of complications was similar between the two groups(P<0.05).Conclusion:Compared with the locking plate system,the bridge combined internal fixation system can effectively improve the operation efficiency,have more benefits on fracture healing,better promote the recovery of patients'function,and reduce the failure rate of internal fixation,thus providing a better choice to treat displaced midshaft clavicle fractures by intraoperative internal fixation.展开更多
文摘We present an experimental study on tilt-tip(TT) and phase-locking(PL) control in a coherent beam combination(CBC) system of adaptive fiber laser array.The TT control is performed using the adaptive fiber-optics collimator(AFOC),and the PL control is realized by the phase modulator(PM).Cascaded and simultaneous controls of TT and PL using stochastic parallel gradient descent(SPGD) algorithm are investigated in this paper.Two-fiber-laser-,four-fiber-laser-,and six-fiber-laser-arrays are employed to study the TT and PL control.In the cascaded control system,only one high-speed CMOS camera is used to collect beam data and a computer is used as the controller.In a simultaneous control system one high-speed CMOS camera and one photonic detector(PD) are employed,and a computer and a control circuit based on field programmable gate array(FPGA) are used as the controllers.Experimental results reveal that both cascaded and simultaneous controls of TT using AFOC and PL using PM in fiber laser array are feasible and effective.Cascaded control is more effective in static control situation and simultaneous control can be applied to the dynamic control system directly.The control signals of simultaneous PL and TT disturb each other obviously and TT and PL control may compete with each other,so the control effect is limited.
基金Supported by the National Natural Science Foundation of China
文摘The phase and frequency locking of microwave, millimeter wave power combining were analysed and summarized in an all-round way. The master/slave phase locking of cavity oscillators, the peer phase locking of mutually coupled oscillators, and the peer phase locking of ring-connected multiple oscillators were investigated. The results of numerical calculations, and the relations of phase to phase locking model and oscillator parameters were given. And the cavity and space power combining aspects for microwave and millimeter wave were presented.
基金Project supported by the National Basic Research Program of China(Grant No.2013CB328902)the National Natural Science Foundation of China(Grant No.61501311)
文摘A microwave power-combining system composed of two Panasonic 2M244-M1 magnetrons based on master–slave injection-locking is demonstrated in this paper. The principle of master–slave injection-locking and the locking condition are theoretical analyzed. Experimental results are consistent with the theoretical analysis and the experimental combined efficiency is higher than 96%. Compared with the external-injection-locked system, the power-combining based on the master–slave injection-locking magnetron is superior by taking out the external solid-state driver and the real-time phase control system. Thus, this power-combining system has great potential for obtaining a high efficiency, high stability, low cost, and high power microwave source.
文摘Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphatically observing fracture healing and shoulder joint function.Methods:Totally 44 elderly patients with Robinson type 2B displaced midshaft clavicle fractures were included from the Department of Orthopaedics,Shenyang Fourth People's Hospital during February 2016 and December 2018,including 23 males and 21 females,mean age(69.8±10.2)years old.The patients were divided into a bridge combined internal fixation system group(bridge group,n=22)and a locking compression plate internal fixation group(plate group,n=22)according to the internal fixation methods.The operation time,intraoperative blood loss,fracture healing time,and postoperative complications were recorded.At 12 months after surgery,the shoulder joint Constant-Murley score and DASH score were used to assess the recovery of joint function.The serum levels of bone turnover biochemical markers procollagen I N-terminal peptide(P1NP),cross-linked Carboxy-terminal telopeptide of typeⅠcollagen(CTX-I),and osteoblast specific factor(OSF)were measured before and 3 months after surgery.Results:The operation time,intraoperative blood loss and fracture healing time of the bridge group were significantly shorter than those of the plate group(P<0.05).Constant scores and DASH scores in the bridge group were significantly better than those of the plate group at 12 months after surgery(P<0.05).Serum levels of CTX-I was significantly decreased,while the P1NP and OSF were significantly increased compared with before surgery in the both groups(P<0.05),and the changes were more obvious in the bridge group(P<0.05).The incidence of complications was similar between the two groups(P<0.05).Conclusion:Compared with the locking plate system,the bridge combined internal fixation system can effectively improve the operation efficiency,have more benefits on fracture healing,better promote the recovery of patients'function,and reduce the failure rate of internal fixation,thus providing a better choice to treat displaced midshaft clavicle fractures by intraoperative internal fixation.