期刊文献+
共找到241篇文章
< 1 2 13 >
每页显示 20 50 100
Coherent beam combination of adaptive fiber laser array with tilt-tip and phase-locking control 被引量:2
1
作者 王雄 王小林 +5 位作者 周朴 粟荣涛 耿超 李新阳 许晓军 舒柏宏 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第2期265-270,共6页
We present an experimental study on tilt-tip(TT) and phase-locking(PL) control in a coherent beam combination(CBC) system of adaptive fiber laser array.The TT control is performed using the adaptive fiber-optics... We present an experimental study on tilt-tip(TT) and phase-locking(PL) control in a coherent beam combination(CBC) system of adaptive fiber laser array.The TT control is performed using the adaptive fiber-optics collimator(AFOC),and the PL control is realized by the phase modulator(PM).Cascaded and simultaneous controls of TT and PL using stochastic parallel gradient descent(SPGD) algorithm are investigated in this paper.Two-fiber-laser-,four-fiber-laser-,and six-fiber-laser-arrays are employed to study the TT and PL control.In the cascaded control system,only one high-speed CMOS camera is used to collect beam data and a computer is used as the controller.In a simultaneous control system one high-speed CMOS camera and one photonic detector(PD) are employed,and a computer and a control circuit based on field programmable gate array(FPGA) are used as the controllers.Experimental results reveal that both cascaded and simultaneous controls of TT using AFOC and PL using PM in fiber laser array are feasible and effective.Cascaded control is more effective in static control situation and simultaneous control can be applied to the dynamic control system directly.The control signals of simultaneous PL and TT disturb each other obviously and TT and PL control may compete with each other,so the control effect is limited. 展开更多
关键词 coherent beam combining tilt-tip control phase-locking control adaptive fiber-optics collimator
原文传递
PHASE AND FREQUENCY LOCKING OF MICROWAVE AND MILLIMETER WAVE POWER COMBINING
2
作者 谢文楷 刘盛纲 《Journal of Electronics(China)》 1994年第4期361-368,共8页
The phase and frequency locking of microwave, millimeter wave power combining were analysed and summarized in an all-round way. The master/slave phase locking of cavity oscillators, the peer phase locking of mutually ... The phase and frequency locking of microwave, millimeter wave power combining were analysed and summarized in an all-round way. The master/slave phase locking of cavity oscillators, the peer phase locking of mutually coupled oscillators, and the peer phase locking of ring-connected multiple oscillators were investigated. The results of numerical calculations, and the relations of phase to phase locking model and oscillator parameters were given. And the cavity and space power combining aspects for microwave and millimeter wave were presented. 展开更多
关键词 Power combining PHASE lockING Frequency lockING Master/slave PHASE lockING PEER COUPLE PHASE lockING SOLID-STATE source RELATIVISTIC microwave device
在线阅读 下载PDF
Power-combining based on master-slave injection-locking magnetron
3
作者 袁萍 张益 +3 位作者 叶文军 朱铧丞 黄卡玛 杨阳 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第7期542-545,共4页
A microwave power-combining system composed of two Panasonic 2M244-M1 magnetrons based on master–slave injection-locking is demonstrated in this paper. The principle of master–slave injection-locking and the locking... A microwave power-combining system composed of two Panasonic 2M244-M1 magnetrons based on master–slave injection-locking is demonstrated in this paper. The principle of master–slave injection-locking and the locking condition are theoretical analyzed. Experimental results are consistent with the theoretical analysis and the experimental combined efficiency is higher than 96%. Compared with the external-injection-locked system, the power-combining based on the master–slave injection-locking magnetron is superior by taking out the external solid-state driver and the real-time phase control system. Thus, this power-combining system has great potential for obtaining a high efficiency, high stability, low cost, and high power microwave source. 展开更多
关键词 magnetron power-combining master–slave injection-locking combined efficiency
原文传递
内外侧联合入路内固定治疗Klammer Ⅱ、Ⅲ型后Pilon骨折疗效分析
4
作者 陈文韬 白晓冬 +7 位作者 刘振宇 高化 王刚 许国强 马骥 王稼田 王逸骏 王宝军 《中国骨与关节损伤杂志》 2025年第10期1030-1033,共4页
目的观察内外侧联合入路内固定治疗Klammer Ⅱ、Ⅲ型后Pilon骨折的临床疗效。方法回顾性分析自2020-01—2023-09采用内外侧联合入路内固定治疗的21例Klammer Ⅱ、Ⅲ型后Pilon骨折,先取踝关节外侧入路充分显露腓骨骨折断端,用撑开器撑开... 目的观察内外侧联合入路内固定治疗Klammer Ⅱ、Ⅲ型后Pilon骨折的临床疗效。方法回顾性分析自2020-01—2023-09采用内外侧联合入路内固定治疗的21例Klammer Ⅱ、Ⅲ型后Pilon骨折,先取踝关节外侧入路充分显露腓骨骨折断端,用撑开器撑开腓骨骨折断端,显露胫骨远端后外侧关节面;再取踝关节内侧入路依次切开至内侧骨折断端,再从腓骨骨折断端进入,内外侧同时清理并松解胫骨远端后侧骨性结构;关节面复位满意后,选择合适长度的空心钉从胫骨前方置入固定后外侧骨折块,再选择合适的解剖锁定钢板经外侧入路固定腓骨,选择合适长度的空心钉经内侧入路固定后内侧骨折块,Klammer Ⅲ型骨折患者需同时经内侧入路置入空心钉固定前内侧骨折块。结果21例均获得随访,随访时间13~25个月,平均18.7个月。所有患者未出现切口感染、骨折复位丢失、骨折不愈合及内固定松动等并发症。骨折均愈合良好,愈合时间为3~5个月,平均3.7个月。末次随访时踝与后足功能AOFAS评分为83~94分,平均88.9分;优11例,良10例。末次随访疼痛VAS评分为0~3分,平均1.2分。结论与后内入路、后外入路及二者联合入路相比,内外侧联合入路局部解剖简单,软组织剥离和损伤小,可减少术中体位变换,充分显露胫骨远端后侧关节面,提供清晰的手术视野,有利于骨折复位和内固定置入,可作为内固定治疗Klammer Ⅱ、Ⅲ型后Pilon骨折的手术入路。 展开更多
关键词 KlammerⅡ、Ⅲ型后Pilon骨折 内外侧联合入路 内固定 空心钉 锁定钢板
原文传递
新型HUI组合钢板桩力学性能研究 被引量:1
5
作者 张永杰 吴早生 +3 位作者 钟振 黄睿 包春燕 徐东阳 《建筑结构》 北大核心 2025年第6期95-101,共7页
组合钢板桩兼具良好的止水效果、抗弯刚度大以及可回收利用等众多优点,为进一步丰富组合钢板桩的组合形式及应用范围,提出一种新型的HUI组合钢板桩,其通过在H型钢的翼缘上焊接双向锁扣使H型钢与U型钢板桩之间连接更加便利和多样。在此... 组合钢板桩兼具良好的止水效果、抗弯刚度大以及可回收利用等众多优点,为进一步丰富组合钢板桩的组合形式及应用范围,提出一种新型的HUI组合钢板桩,其通过在H型钢的翼缘上焊接双向锁扣使H型钢与U型钢板桩之间连接更加便利和多样。在此基础上,综合采用理论计算、室内试验以及ABAQUS数值软件对HUI组合钢板桩的抗弯性能、锁扣抗拉性能以及抗弯刚度折减效应展开研究。结果显示:HUI组合钢板桩的截面抗弯刚度对比单一U型钢板桩有明显提升,锁扣的抗拉承载力为832kN。HUI组合钢板桩的抗弯试验表明,锁扣焊接试件的抗弯性能明显优于锁扣自由连接的试件,锁扣焊接试件的最大抗弯强度为400kN,而锁扣自由连接的试件的最大抗弯强度只有300kN。基于抗弯试验的挠度测量,通过增量法得到实际应用中钢板桩的抗弯刚度折减系数介于055~064之间。最后,通过对比抗弯试验与数值模拟的结果,发现两者结果相对吻合。 展开更多
关键词 组合钢板桩 双向锁扣 组合形式 抗弯性能 抗拉性能 刚度折减
在线阅读 下载PDF
多种修复工艺结合在长距离排水管道非开挖修复中的应用 被引量:1
6
作者 谢敬永 《工程建设与设计》 2025年第5期209-211,共3页
阐述了现阶段较为广泛应用的紫外光固化非开挖修复工艺和快速锁点状非开挖修复工艺,分析了这两种非开挖修复工艺的优缺点。通过调查研究常规市政排水管道非开挖修复工艺无法完成的长距离修复作业的现状,提出了将紫外光固化非开挖修复工... 阐述了现阶段较为广泛应用的紫外光固化非开挖修复工艺和快速锁点状非开挖修复工艺,分析了这两种非开挖修复工艺的优缺点。通过调查研究常规市政排水管道非开挖修复工艺无法完成的长距离修复作业的现状,提出了将紫外光固化非开挖修复工艺与快速锁修复工艺相结合的综合施工模式,最终实现了对长距离排水管道进行非开挖修复的目的。 展开更多
关键词 排水管道 修复工艺 紫外光固化非开挖修复 快速锁 结合
在线阅读 下载PDF
大型省水船闸省水池布置形式研究
7
作者 纪懿桓 阚得静 汤建宏 《水运工程》 2025年第1期102-106,共5页
针对建设场地局限且上下游水位变幅较大时,传统的省水船闸省水池布置形式(开敞式和封闭式)均不能较好地适应设计需求的问题,进行省水池新的布置形式研究,提出组合式布置的概念,即多个省水池中的部分省水池相对另一部分省水池沿水平方向... 针对建设场地局限且上下游水位变幅较大时,传统的省水船闸省水池布置形式(开敞式和封闭式)均不能较好地适应设计需求的问题,进行省水池新的布置形式研究,提出组合式布置的概念,即多个省水池中的部分省水池相对另一部分省水池沿水平方向上错位设置,且多个省水池中的部分省水池相对另一部分省水池沿竖直方向上也错位设置。实践证明,采用该布置形式,既能较好地适应狭窄的场地条件、又能适应上下游较大的水位变幅,很好地满足设计需求。依托工程采用该布置形式并已进入施工建造阶段,该技术可为类似条件的省水船闸设计提供参考。 展开更多
关键词 省水船闸 省水池布置形式 组合式
在线阅读 下载PDF
复杂环境下改建船闸高陡边坡组合支护技术 被引量:2
8
作者 易放辉 黄圣平 +1 位作者 张聪 邹开明 《水运工程》 2025年第2期225-231,共7页
受制于地形地貌、地质条件、结构施工以及地基防渗等因素,我国中东部地区内河船闸施工条件复杂,而此复杂条件下改建船闸高陡边坡支护技术研究成果较少。依托湖南省首个在建27 m高水头差洪江枢纽改建船闸工程,针对复杂环境下船闸施工面... 受制于地形地貌、地质条件、结构施工以及地基防渗等因素,我国中东部地区内河船闸施工条件复杂,而此复杂条件下改建船闸高陡边坡支护技术研究成果较少。依托湖南省首个在建27 m高水头差洪江枢纽改建船闸工程,针对复杂环境下船闸施工面临的高边坡施工稳定性难题,提出“框格梁+预应力锚索”组合支护技术,并通过坡面沉降变形、锚索内力现场测试手段分析高边坡安全稳定性,评价该防护技术应用效果。研究结果表明:现场采用该支护技术后,船闸高边坡坡面沉降变形日均最大值为0.34 mm/d,累计沉降最大值8.3 mm,远小于日均3 mm/d、累计沉降值20 mm的报警值;“框格梁+预应力锚索”组合支护结构主要承受拉力作用且数值较小,最大拉力小于1 000 kN的设计限值,船闸高边坡支护结构设计布局合理,抑制边坡楔形体滑移效果良好,高边坡处于安全稳定状态。研究成果可为类似工程提供借鉴。 展开更多
关键词 改建船闸 高陡边坡 “框格梁+预应力锚索”组合支护 边坡楔形体
在线阅读 下载PDF
Reissner-Mindlin板模型的Locking-free有限元(英文)
9
作者 胡兵 《四川大学学报(自然科学版)》 CAS CSCD 北大核心 2001年第2期166-170,共5页
利用Reissner-Mindlin板问题的组合杂交有限元方法,提出了一类Locking-free有限元.
关键词 组合杂交有限元法 Reissner-Mindlin板模型 locking-free有限元
在线阅读 下载PDF
现浇箱梁支架体系施工方案研究
10
作者 吴启东 《山西交通科技》 2025年第2期107-110,共4页
为保障现浇预应力混凝土箱梁结构施工的安全性与可靠性,针对桥梁施工中支架体系的应用开展研究。通过梳理扣件式、碗扣式、盘扣式及组合式等多种支架体系的结构特点与适用性,重点分析盘扣式与组合式支架体系在某实际工程项目中的布置方... 为保障现浇预应力混凝土箱梁结构施工的安全性与可靠性,针对桥梁施工中支架体系的应用开展研究。通过梳理扣件式、碗扣式、盘扣式及组合式等多种支架体系的结构特点与适用性,重点分析盘扣式与组合式支架体系在某实际工程项目中的布置方式与施工工艺,结合工程实例对各类型支架体系的受力性能、构造效率及施工适应性进行对比。结果表明,盘扣式钢管支架具备良好的承载能力与施工便捷性,组合式支架体系则在高支架、大跨度现浇箱梁中表现出更优的整体稳定性与安全冗余度。研究结论可为类似桥梁工程的支架体系选型与施工组织提供技术支撑与经验参考。 展开更多
关键词 现浇箱梁 盘扣式 组合式 支架体系 稳定性
在线阅读 下载PDF
两种内固定方式治疗锁骨中段骨折的疗效比较
11
作者 孙毅东 迟欣 《临床骨科杂志》 2025年第3期386-390,共5页
目的比较桥接组合式内固定系统和锁定加压钢板治疗锁骨中段骨折的疗效。方法将80例锁骨中段骨折患者根据治疗方式的不同分为观察组(采用桥接组合式内固定系统治疗,40例)及对照组(采用锁定加压钢板治疗,40例)。记录手术时间、切口长度、... 目的比较桥接组合式内固定系统和锁定加压钢板治疗锁骨中段骨折的疗效。方法将80例锁骨中段骨折患者根据治疗方式的不同分为观察组(采用桥接组合式内固定系统治疗,40例)及对照组(采用锁定加压钢板治疗,40例)。记录手术时间、切口长度、术中出血量、骨折愈合时间、肩关节活动度及术后并发症发生情况。末次随访时采用Constant评分评价肩关节功能。结果患者均获得随访,时间8~16个月。手术时间、术中出血量观察组短(少)于对照组(P<0.05)。切口长度、骨折愈合时间两组比较差异均无统计学意义(P>0.05)。肩关节活动度术后2个月观察组均优于对照组(P<0.05),末次随访时两组比较差异均无统计学意义(P>0.05)。末次随访时肩关节Constant评分两组比较差异无统计学意义(P>0.05)。除观察组1例出现肩关节外展功能受限、对照组1例出现肩峰下撞击综合征外,两组术后均无骨折不愈合、内固定物断裂、再骨折等并发症发生。结论锁定加压钢板及桥接组合式内固定系统治疗锁骨中段骨折均可达到满意的临床疗效,但桥接组合式内固定系统具有缩短手术时间、减少术中出血的优点,更利于患者肩关节功能的早期恢复。 展开更多
关键词 桥接组合式内固定系统 锁骨中段骨折 锁定加压钢板
暂未订购
Effects of bridge combined internal fixation system internal fixation on fracture healing and shoulder joint function in elderly patients with displaced midshaft clavicle fractures 被引量:1
12
作者 Wang Guang-Xin Xiao Wan-Jun +1 位作者 Wang Chen Liang Qing-Wei 《Journal of Hainan Medical University》 2019年第18期35-39,共5页
Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphaticall... Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphatically observing fracture healing and shoulder joint function.Methods:Totally 44 elderly patients with Robinson type 2B displaced midshaft clavicle fractures were included from the Department of Orthopaedics,Shenyang Fourth People's Hospital during February 2016 and December 2018,including 23 males and 21 females,mean age(69.8±10.2)years old.The patients were divided into a bridge combined internal fixation system group(bridge group,n=22)and a locking compression plate internal fixation group(plate group,n=22)according to the internal fixation methods.The operation time,intraoperative blood loss,fracture healing time,and postoperative complications were recorded.At 12 months after surgery,the shoulder joint Constant-Murley score and DASH score were used to assess the recovery of joint function.The serum levels of bone turnover biochemical markers procollagen I N-terminal peptide(P1NP),cross-linked Carboxy-terminal telopeptide of typeⅠcollagen(CTX-I),and osteoblast specific factor(OSF)were measured before and 3 months after surgery.Results:The operation time,intraoperative blood loss and fracture healing time of the bridge group were significantly shorter than those of the plate group(P<0.05).Constant scores and DASH scores in the bridge group were significantly better than those of the plate group at 12 months after surgery(P<0.05).Serum levels of CTX-I was significantly decreased,while the P1NP and OSF were significantly increased compared with before surgery in the both groups(P<0.05),and the changes were more obvious in the bridge group(P<0.05).The incidence of complications was similar between the two groups(P<0.05).Conclusion:Compared with the locking plate system,the bridge combined internal fixation system can effectively improve the operation efficiency,have more benefits on fracture healing,better promote the recovery of patients'function,and reduce the failure rate of internal fixation,thus providing a better choice to treat displaced midshaft clavicle fractures by intraoperative internal fixation. 展开更多
关键词 BRIDGE combinED INTERNAL FIXATION locking plate old age Mid-clavicular displacement FRACTURE INTERNAL FIXATION FRACTURE healing shoulder function Bone turnover
暂未订购
一种基于嵌套结构的锁频锁相高功率微波振荡器仿真研究 被引量:1
13
作者 李家文 葛行军 +4 位作者 党方超 张鹏 邓如金 胡晓冬 李志敏 《强激光与粒子束》 CAS CSCD 北大核心 2024年第3期24-30,共7页
高功率微波(HPM)产生器件通过增加慢波结构的过模比使得功率容量显著提高。嵌套型结构让过模器件的空心结构或内导体结构得到使用,同时嵌套型器件的低阻抗使得其与低阻脉冲功率源能良好匹配。基于内外嵌套结构提出了一种锁频锁相高功率... 高功率微波(HPM)产生器件通过增加慢波结构的过模比使得功率容量显著提高。嵌套型结构让过模器件的空心结构或内导体结构得到使用,同时嵌套型器件的低阻抗使得其与低阻脉冲功率源能良好匹配。基于内外嵌套结构提出了一种锁频锁相高功率微波振荡器。相对于传统的锁频锁相方法,提出了基于耦合波导实现锁频锁相的新方法。内外相对论速调管振荡器(RKO)产生的微波信号通过耦合波导泄漏到高频结构中,对电子束进行预调制,从而实现锁频锁相。另外,为实现内外高功率微波通道合成,设计了双通道功率合成器。在振荡器的工作频点,功率合成器能弥补振荡器两输出通道相位差,使得功率合成效率提高,合成效率为98.3%。在二极管电压575 kV,磁场强度0.6 T条件下,内外RKO的微波输出功率分别为2.2 GW和3.2 GW,频率差波动小于20 MHz,相位差稳定在10°附近;加载双通道功率合成器,仿真结果表明,微波输出功率为5.31 GW,功率效率32.2%。结果表明,嵌套器件在互锁状态时,振荡器饱和时间缩短,输出功率增大。 展开更多
关键词 高功率微波 锁频锁相 嵌套结构 相对论速调管振荡器 功率合成
在线阅读 下载PDF
按键式密码电子锁电路的设计
14
作者 王彦勇 刘艳萍 《山西电子技术》 2024年第4期4-7,共4页
数字电路的设计在计算机、电子和自动化等专业中占据着非常重要的地位,另一方面,现代的教育理念要求加强对学生分析能力、实践动手能力和创新应用能力的培养。为了更好地将理论知识与实践结合起来,详细地阐述了利用集成芯片和门电路设... 数字电路的设计在计算机、电子和自动化等专业中占据着非常重要的地位,另一方面,现代的教育理念要求加强对学生分析能力、实践动手能力和创新应用能力的培养。为了更好地将理论知识与实践结合起来,详细地阐述了利用集成芯片和门电路设计生活中常见的电子密码锁设计过程,包括核心器件触发器的选择、通过几种方案的比较确定最优设计方案、密码锁的工作过程及相关电路的设计。通过实验室实验验证,增强了学生对电路的感性认识,提高了学生的学习兴趣与效率。 展开更多
关键词 数字电路 密码锁 D触发器
在线阅读 下载PDF
锁定钢板联合拉力螺钉内固定术与非锁定钢板内固定术对踝关节骨折合并下胫腓分离患者预后的影响 被引量:11
15
作者 沙川 马超 那键 《川北医学院学报》 CAS 2024年第4期511-515,共5页
目的:探究锁定钢板结合拉力螺钉内固定术对踝关节骨折合并下胫腓分离患者预后的影响。方法:回顾性分析176例踝关节骨折合并下胫腓分离患者的临床资料。将176例患者按术式不同分为对照组(n=74)与观察组(n=102),比较两组患者手术相关指标... 目的:探究锁定钢板结合拉力螺钉内固定术对踝关节骨折合并下胫腓分离患者预后的影响。方法:回顾性分析176例踝关节骨折合并下胫腓分离患者的临床资料。将176例患者按术式不同分为对照组(n=74)与观察组(n=102),比较两组患者手术相关指标、炎症因子水平、骨代谢情况、关节功能及并发症发生情况。结果:观察组患者手术、住院及骨折愈合时间均短于对照组(P<0.05);术后3 d及1周,观察组白细胞介素6、白细胞介素8、去甲肾上腺素、C反应蛋白水平均低于对照组(P<0.05);术后3、6个月,观察组患者骨碱性磷酸酶、血清骨钙素均高于对照组(P<0.05),β-胶原降解产物低于对照组(P<0.05);术后6个月,观察组关节功能各维度得分均高于对照组(P<0.05),并发症发生率低于对照组(P<0.05)。结论:对于踝关节骨折并伴有下胫腓分离患者而言,锁定钢板与拉力螺钉内固定术结合使用,更能降低炎症因子水平,增强骨代谢能力,提升关节功能,减少并发症的发生几率,有利于促进恢复和改善预后,具有临床应用价值。 展开更多
关键词 锁定钢板联合拉力螺钉内固定术 非锁定钢板内固定术 踝关节骨折合并下胫腓分离 预后
暂未订购
鲁班锁型人工鱼礁礁体设计及稳定性分析
16
作者 戢治鹏 董坤 +1 位作者 蒋济同 杜德润 《海洋湖沼通报(中英文)》 CSCD 北大核心 2024年第6期17-23,共7页
针对现浇混凝土人工鱼礁体型大、运输效率低等问题,本文设计了一种鲁班锁连接的装配式人工鱼礁,将小尺寸杆件通过卯榫连接便可组装成大空方的空间体,能有效节省运输及投放成本,并根据山东日照近海某人工鱼礁区投放礁体海域的海况条件,... 针对现浇混凝土人工鱼礁体型大、运输效率低等问题,本文设计了一种鲁班锁连接的装配式人工鱼礁,将小尺寸杆件通过卯榫连接便可组装成大空方的空间体,能有效节省运输及投放成本,并根据山东日照近海某人工鱼礁区投放礁体海域的海况条件,对此礁体进行了稳定性计算。结果表明:在波、流共同作用下,礁体最大受力为7.252 kN,最大作用力矩为8.702 kN·m,礁体抗滑移安全系数为3.4,抗倾覆安全系数为4.5,均满足礁体稳定条件,即礁体在该海域不会发生滑移及倾覆。为今后设计适宜我国近海海域环境特征的装配式人工鱼礁提供重要的参考价值。 展开更多
关键词 鲁班锁 装配式 人工鱼礁 稳定性
原文传递
双棒桥接组合内固定系统治疗锁骨中段骨折的疗效 被引量:3
17
作者 李伟康 蔡进奎 +4 位作者 李漌涼 肖智勇 许海甲 廖文 李章华 《临床骨科杂志》 2024年第1期56-60,共5页
目的探讨双棒桥接组合内固定系统治疗锁骨中段骨折的疗效。方法将63例锁骨中段骨折患者按照内固定方式不同分为观察组(采用双棒桥接组合内固定系统治疗,29例)和对照组(采用锁定单钢板内固定治疗,34例)。记录两组术中出血量、手术时间、... 目的探讨双棒桥接组合内固定系统治疗锁骨中段骨折的疗效。方法将63例锁骨中段骨折患者按照内固定方式不同分为观察组(采用双棒桥接组合内固定系统治疗,29例)和对照组(采用锁定单钢板内固定治疗,34例)。记录两组术中出血量、手术时间、骨折愈合时间、术后并发症发生情况及肩关节活动度。采用Constant-Murley评分评价肩关节功能恢复情况。结果患者均获得随访,时间12~18个月。术中出血量、手术时间观察组多(长)于对照组(P<0.01);骨折愈合时间观察组短于对照组(P<0.05)。术后并发症发生率两组比较差异无统计学意义(P>0.05)。肩关节活动度、Constant-Murley评分:术后12周观察组均大于对照组(P<0.05);术后1年两组比较差异均无统计学意义(P>0.05)。结论双棒桥接组合内固定系统治疗锁骨中段骨折固定强度大、稳定性高,可对骨折断端持续动态加压,促进骨折愈合,更利于患者早期进行康复锻炼及肩关节功能的恢复。 展开更多
关键词 锁骨中段骨折 双棒桥接组合内固定系统 锁定钢板
暂未订购
BDS信号失锁下基于自适应因子图的列车组合定位模型 被引量:1
18
作者 程相 王运明 +1 位作者 王新屏 初宪武 《铁道科学与工程学报》 EI CAS CSCD 北大核心 2024年第3期1146-1155,共10页
针对列车运行环境复杂,容易产生BDS信号失锁,影响BDS/IMU列车定位系统的精确性问题,提出了基于自适应因子图的BDS/IMU/OD列车组合定位模型。在BDS/IMU列车定位系统的基础上,引入里程计(Odometer,OD)定位技术,利用北斗卫星导航系统(Beido... 针对列车运行环境复杂,容易产生BDS信号失锁,影响BDS/IMU列车定位系统的精确性问题,提出了基于自适应因子图的BDS/IMU/OD列车组合定位模型。在BDS/IMU列车定位系统的基础上,引入里程计(Odometer,OD)定位技术,利用北斗卫星导航系统(Beidou Navigation Satellite System,BDS)与惯性测量元件(Inertial Measurement Unit,IMU)、OD 3类传感器获取列车量测信息,根据因子图理论,将多源量测信息描述为状态空间方程,抽象BDS、IMU、OD因子节点和先验因子,确定因子节点与变量节点之间的无向连接关系,建立多变量列车组合定位因子图模型,解算列车的位置信息。当BDS信号产生变化时,借助因子图的即插即用特性,提出了自适应因子算法,动态调整列车组合定位因子图模型结构。在BDS信息部分失锁时,利用BDS的部分信息,建立BDS/IMU/OD列车组合定位因子图模型,在BDS信息完全失锁时,转换为IMU/OD列车组合定位因子图模型,抑制BDS完全失锁造成的发散误差。利用卡尔曼算法、因子图算法、自适应因子图算法进行了列车定位的仿真分析,在BDS信息部分失锁时,自适应因子图模型的定位位置均方根误差比卡尔曼算法分别降低了52.3%、48.2%和42.7%,比因子图算法分别降低了34.8%、27.0%和25.2%。在BDS信息完全失锁时,自适应因子图模型的定位位置误差比卡尔曼算法分别降低了46.7%、46.7%和50%。自适应因子图算法提高了BDS信息失锁的情况下的列车定位精度,实现了不同传感器之间的即插即用,为构建高精确性、强鲁棒性、高可扩展性的列车组合定位系统提供模型支持。 展开更多
关键词 列车组合定位 BDS信号失锁 因子图 BDS/IMU/OD 自适应因子
在线阅读 下载PDF
桥接组合式内固定和锁定加压钢板治疗股骨干粉碎性骨折的疗效比较 被引量:3
19
作者 张成 张正阳 《临床外科杂志》 2024年第4期364-367,共4页
目的 比较桥接组合式内固定系统和锁定加压钢板治疗股骨干粉碎性骨折的疗效。方法 2017年1月~2021年6月收治的股骨干粉碎性骨折病人97例,其中42例实施锁定加压钢板内固定手术(钢板组),55例实施桥接组合式内固定手术(桥接组),随访至少12... 目的 比较桥接组合式内固定系统和锁定加压钢板治疗股骨干粉碎性骨折的疗效。方法 2017年1月~2021年6月收治的股骨干粉碎性骨折病人97例,其中42例实施锁定加压钢板内固定手术(钢板组),55例实施桥接组合式内固定手术(桥接组),随访至少12个月。比较两组的围手术期资料、随访资料和并发症情况。结果 钢板组和桥接组的手术时间分别为(95.37±19.31)分钟和(77.83±15.32)分钟,术中出血分别为(425.37±47.56)ml和(398.72±43.29)ml,术后引流量分别为(123.42±19.87)ml和(106.39±14.20)ml,住院时间分别为(19.31±4.26)天和(16.2 4±3.79)天,两组比较差异有统计学意义(P<0.05);术后随访1年,桥接组和钢板组的髋关节ROM分别为(132.31±15.47)°和(125.35±17.11)°、膝关节活动度ROM分别为(139.68±16.69)°和(131.49±18.24)°,两组比较差异有统计学意义(P<0.05),骨折愈合时间分别为(5.42±0.87)个月和(6.28±1.07)个月,Harris评分分别为(83.49±9.31)分和(77.57±6.39)分,HSS评分分别为(85.35±6.90)分和(80.32±7.79)分,两组比较差异有统计学意义(P<0.05)。两组切口长度和并发症比较,差异无统计学意义。结论 相比于锁定加压钢板,桥接组合式内固定治疗股骨干粉碎性骨折的手术创伤更小,骨折愈合更快,术后功能更好。 展开更多
关键词 股骨干粉碎性骨折 桥接组合式内固定 锁定加压钢板 疗效对比
暂未订购
新型组合式锁定钢板治疗股骨转子下骨折的疗效 被引量:1
20
作者 刘圆 赵敏 +2 位作者 施明宏 周江军 王建平 《临床骨科杂志》 2024年第6期856-860,共5页
目的探讨新型组合式锁定钢板治疗股骨转子下骨折的疗效。方法将46例股骨转子下骨折患者根据治疗方式不同分为观察组(采用新型组合式锁定钢板固定治疗,23例)和对照组(采用股骨重建髓内钉固定治疗,23例)。记录手术情况、骨折愈合时间、并... 目的探讨新型组合式锁定钢板治疗股骨转子下骨折的疗效。方法将46例股骨转子下骨折患者根据治疗方式不同分为观察组(采用新型组合式锁定钢板固定治疗,23例)和对照组(采用股骨重建髓内钉固定治疗,23例)。记录手术情况、骨折愈合时间、并发症发生情况,采用髋关节Harris评分评价疗效。结果患者均获得随访,时间10~24个月。手术时间、术中出血量、住院时间、骨折愈合时间观察组均短(少)于对照组(P<0.05)。术后1、3、6个月髋关节功能Harris评分两组比较差异均无统计学意义(P>0.05)。对照组1例因股骨外侧壁粉碎性骨折,术后骨不连,二期行更换内固定、自体植骨治疗后骨折愈合。结论新型组合式锁定钢板治疗股骨转子下骨折具有术中出血少及手术时间、住院时间、骨折愈合时间短等优点。 展开更多
关键词 新型组合式锁定钢板内固定系统 髓内固定 股骨转子下骨折
暂未订购
上一页 1 2 13 下一页 到第
使用帮助 返回顶部