期刊文献+
共找到329,088篇文章
< 1 2 250 >
每页显示 20 50 100
A review of the standardized measurement of the characteristics of graphene-based materials
1
作者 Zhang Donghui Li Wan +2 位作者 Ou Bingxian Wang Liangwang Ge Guanglu 《新型炭材料(中英文)》 北大核心 2026年第1期91-108,共18页
Standardization is necessary for the early industrialization of the new materials and technology.It is achieved by having agreed practices for the measurement of properties and other characteristics.The promising use ... Standardization is necessary for the early industrialization of the new materials and technology.It is achieved by having agreed practices for the measurement of properties and other characteristics.The promising use of graphene-based materials in fields like electronics,energy,and composites has resulted in standards for their nomenclature,the measurement of key characteristics,and their specification,etc.Among these,standards for measuring the key characteristics are crucial.The critical parameters are the number of layers,the type and concentration of defects and functional groups,elemental composition,sheet resistance,and carrier mobility.Standards for characterizing these have been analyzed by the International Organization for Standardization Technical Committee in ISO/TC229 and the International Electrotechnical Commission Technical Committee in IEC/TC113.These give details of applicable or preferred samples,the fundamental principles of the techniques,specific precautions,and points for attention in the relevant standards.The pivotal role of the ISO/TC229 and IEC/TC113 standards is considered and challenges and future trends are outlined. 展开更多
关键词 Nanotechnology Graphene-based materials measurement standards Critical characteristics Quality control
在线阅读 下载PDF
Comparison of three different instruments for vault measurements after implantable collamer lens implantation
2
作者 Bo-Liang Li Ming-Rui Cheng +6 位作者 Wei-Teng Chang Ya-Di Lei Guang-Han Xu Ming-Wei Li Zhi-Wei Mao Xun Chen Xiao-Ying Wang 《International Journal of Ophthalmology(English edition)》 2026年第3期475-482,共8页
AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)follow... AIM:To evaluate the differences and consistency of vault measurements obtained by Scheimpflug tomography(Pentacam),anterior segment optical coherence tomography(AS-OCT,CASIA II),and ultrasound biomicroscopy(UBM)following implantable collamer lens(ICL)V4c implantation.METHODS:Vault measurements were acquired using three modalities:Pentacam,CASIA II AS-OCT,and UBM.Repeated-measures analysis of variance was used to compare the vault values obtained by the three devices.The correlation and consistency of measurements among the three instruments were assessed using the Pearson correlation coefficient,intraclass correlation coefficient(ICC),and Bland-Altman plots.RESULTS:This retrospective study enrolled 210 myopic eyes of 210 patients(158 women and 52 men)who underwent ICL implantation:108 eyes had a myopic ICL V4c implanted,and 102 eyes had a toric ICL V4c implanted.The mean vault values measured by Pentacam,CASIA II,and UBM were 452.64±204.20μm,538.57±203.54μm,and 560.95±227.54μm,respectively,with statistically significant differences among the three groups(P<0.05).Pearson correlation analysis showed strong positive correlations between vault values measured by different instruments(all P<0.001).ICC results indicated good consistency among the three measurement modalities(all P<0.001).Stratified analysis revealed that when the vault value was≤250μm,the correlation and consistency of measurements across the three instruments were lower than those in the medium and high vault subgroups.CONCLUSION:Vault values measured by Pentacam are lower than those obtained by CASIA II and UBM,with UBM yielding the highest mean vault values.Measurements from the three instruments are not interchangeable but can serve as mutual references due to their significant correlation and good overall consistency.Pentacam and CASIA II demonstrate the highest consistency in vault measurement.Notably,when the vault value is≤250μm,the consistency between Pentacam and the other two instruments decreases significantly. 展开更多
关键词 implantable collamer lens vault measurement scheimpflug tomography anterior segment optical coherence tomography ultrasound biomicroscopy measurement consistency
原文传递
Spatial and temporal distribution characteristics of low-visibility phenomena in Xinjiang based on instrument measurements
3
作者 WANG Xiuqin NING Jinge +3 位作者 AN Dongliang LU Xinyu WANG Minzhong WU Chunxia 《Journal of Mountain Science》 2026年第3期1006-1024,共19页
Low-visibility phenomena strongly impact the environment,as well as transportation,aviation and other fields that are closely related to people's livelihoods;thus,they represent important ecological issues of soci... Low-visibility phenomena strongly impact the environment,as well as transportation,aviation and other fields that are closely related to people's livelihoods;thus,they represent important ecological issues of social concern.Based on observation data concerning low-visibility phenomena derived from 105 national meteorological stations in Xinjiang,China over the past 20 years,we systematically analyzed the differences between manual and instrument observations for six types of low-visibility phenomena,with a focus on exploring their spatiotemporal distribution characteristics using instrument data.The results revealed that low-visibility phenomena were dominated by fog-and haze-related events(mist,fog,and haze)in northern Xinjiang and dust-related events(dust storms,blowing sand,and floating dust)in southern Xinjiang,with transitional characteristics observed in eastern Xinjiang.Compared with manual observations,the instrument measurements significantly improved the fine-scale low-visibility phenomenon identification process.On the basis of the instrument observation data,spatial-dimension analysis results indicated that low-visibility phenomena in Xinjiang were significantly influenced by terrain factors.Constrained by the Tianshan Mountains,haze-like phenomena formed a core agglomeration area in northern Xinjiang,whereas dust-and sand-related phenomena radiated outward,with the Taklimakan Desert at the center.Moreover,the gripping effect of the terrain promoted dust transmission along low-altitude channels.Temporally,fog-and haze-related phenomena occurred mainly during autumn and winter,and the proportion of these events decreased from 76.7%to 55.1%.The fog-and haze-related phenomena demonstrated a U-shaped rebound trend,while the proportion of mist phenomena decreased by 34.2%.Dust storms occurred during spring,accounting for 23.3%to 44.9%of all storms.Instrument measurement technology has the advantages of high spatial and temporal resolutions and multiparameter coordination but provides a limited dust-haze mixed-pollution identification capacity.This study provides crucial reference data for enhancing the understanding of low-visibility events in Xinjiang and the potential responses while improving the accuracy of pollution source tracking and meteorological process diagnosis tasks. 展开更多
关键词 Instrument measurement Low visibility DISTRIBUTION XINJIANG
原文传递
Calibration of a multiwavelength co-phase measurement system for a segmented solar telescope
4
作者 Junke Wang Zhenyu Jin +2 位作者 Yichun Dai Bin Wang Xiqun Wang 《Astronomical Techniques and Instruments》 2026年第2期121-131,共11页
The segmented solar telescope described in this study employs a simultaneous dual-wavelength measurement technique to achieve co-phase alignment.To meet the measurement requirements of a 20μm range,5 nm root mean squ... The segmented solar telescope described in this study employs a simultaneous dual-wavelength measurement technique to achieve co-phase alignment.To meet the measurement requirements of a 20μm range,5 nm root mean square precision,and edge jump rates of<10^(−6),this study focused on calibrating the dual-wavelength measurement system for the segmented-mirror solar telescope.Analysis of the relative error in the measurement system revealed that assembly-induced errors such as defocus,translation,scaling,and rotation markedly degrade measurement accuracy.To address these issues,we propose a defocus error compensation algorithm,based on the light intensity distribution of the point spread function(PSF)and an affine transformation model,to calibrate spatial pose deviations across the two measurement channels.A dual-wavelength measurement system was implemented on a segmented-mirror experimental platform for calibration.Experimental results demonstrated that the mean relative error decreased from−0.6423 to−0.0345 nm after calibration,reflecting improved reliability and stability of the co-phase measurements. 展开更多
关键词 Segmented mirror CALIBRATION Phase measurement
在线阅读 下载PDF
Exploring recent breakthroughs in robotic biomechanical and electrophysiological measurement tools
5
作者 Hui-Yao Shi Si Tang +3 位作者 Jia-Lin Shi Peng Yu Chan-Min Su Lian-Qing Liu 《Biomedical Engineering Communications》 2026年第1期35-47,共13页
Single-cell biomechanics and electrophysiology measuring tools have transformed biological research over the last few decades,which enabling a comprehensive and nuanced understanding of cellular behavior and function.... Single-cell biomechanics and electrophysiology measuring tools have transformed biological research over the last few decades,which enabling a comprehensive and nuanced understanding of cellular behavior and function.Despite their high-quality information content,these single-cell measuring techniques suffer from laborious manual processing by highly skilled workers and extremely low throughput(tens of cells per day).Recently,numerous researchers have automated the measurement of cell mechanical and electrical signals through robotic localization and control processes.While these efforts have demonstrated promising progress,critical challenges persist,including human dependency,learning complexity,in-situ measurement,and multidimensional signal acquisition.To identify key limitations and highlight emerging opportunities for innovation,in this review,we comprehensively summarize the key steps of robotic technologies in single-cell biomechanics and electrophysiology.We also discussed the prospects and challenges of robotics and automation in biological research.By bridging gaps between engineering,biology,and data science,this work aims to stimulate interdisciplinary research and accelerate the translation of robotic single-cell technologies into practical applications in the life sciences and medical fields. 展开更多
关键词 BIOMECHANICS ELECTROPHYSIOLOGY micro-nano manipulation automated cell measurement ROBOTICS
在线阅读 下载PDF
A novel deviation measurement for scheduled intelligent transportation system via comparative spatial-temporal path networks
6
作者 Daozhong Feng Jiajian Lai +1 位作者 Wenxuan Wei Bin Hao 《Digital Communications and Networks》 2026年第1期101-118,共18页
Transit managers can use Intelligent Transportation System technologies to access large amounts of data to monitor network status.However,the presentation of the data lacks structural information.Existing single-netwo... Transit managers can use Intelligent Transportation System technologies to access large amounts of data to monitor network status.However,the presentation of the data lacks structural information.Existing single-network description technologies are ineffective in representing the temporal and spatial characteristics simultaneously.Therefore,there is a need for complementary methods to address these deficiencies.To address these limitations,this paper proposes an approach that combines Network Snapshots and Temporal Paths for the scheduled system.A dual information network is constructed to assess the degree of operational deviation considering the planning tasks.To validate the effectiveness,discussions are conducted through a modified cosine similarity calculation on theoretical analysis,delay level description,and the ability to identify abnormal dates.Compared to some state-of-the-art methods,the proposed method achieves an average Spearman delay correlation of 0.847 and a relative distance of 3.477.Furthermore,case analyses are invested in regions of China's Mainland,Europe,and the United States,investigating both the overall and sub-regional network fluctuations.To represent the impact of network fluctuations in sub-regions,a response loss value was developed.The times that are prone to fluctuations are also discussed through the classification of time series data.The research can offer a novel approach to system monitoring,providing a research direction that utilizes individual data combined to represent macroscopic states.Our code will be released at https://github.com/daozhong/STPN.git. 展开更多
关键词 Intelligent transportation system Air traffic network Deviation measurement Spatial-temporal path networks Operational monitoring
在线阅读 下载PDF
Advances and Prospects in Body-Size Measurement of Sheep:From 2D Vision to 3D Reconstruction and 2D-3D Fusion
7
作者 DAI Weijiao LIANG Yudongchen +5 位作者 ZHOU Yong YAO Chao ZHANG Cheng SONG Yongjian LI Guoliang TIAN Fang 《智慧农业(中英文)》 2026年第1期120-147,共28页
[Significance]In alignment with the national germplasm security strategy,current research efforts are accelerating the adoption of precision breeding in sheep.Within the whole-genome selection,accurate phenotyping of ... [Significance]In alignment with the national germplasm security strategy,current research efforts are accelerating the adoption of precision breeding in sheep.Within the whole-genome selection,accurate phenotyping of body morphometrics is critical for assessing growth performance and breeding value.Traditional manual measurements are inefficient,prone to human error,and may cause stress to sheep,limiting their suitability for precision sheep management.By summarizing the applications of sheep body size measurement technologies and analyzing their development directions,this paper provides theoretical references and practical guidance for the research and application of non contact sheep body size measurement.[Progress]This review synthesizes progress across three principal methodological paradigms:two-dimensional(2D)image-based techniques,three-dimensional(3D)point cloud-based approaches,and integrated 2D-3D fusion systems.2D methods,employing either handcrafted geometric features or deep learning-based keypoint detector algorithms,are cost-effective and operationally simple but sensitive to variation in imaging conditions and unable to capture critical circumference metrics.3D point-cloud approaches enable precise reconstruction of full animal morphology,supporting comprehensive body-size acquisition with higher accuracy,yet face challenges including high hardware costs,complex data workflows,and sensitivity to posture variability.Hybrid 2D-3D fusion systems combine semantic richness from RGB imagery with geometric completeness from point clouds.Having been effectively validated in other livestock specise,e.g.,cattle and pigs,these fusion systems have demonstrated excellent performance,providing important technical references and practical insights for sheep body size measurement.[Conclusions and Prospects]Firstly,future research should focus on constructing large-scale,high-quality datasets for sheep body size measurement that encompass diverse breeds,growth stages,and environmental conditions,thereby enhancing model robustness and generalization.Secondly,the development of lightweight artificial intelligence models is essential.Techniques such as model compression,quantization,and algorithmic optimization can substantially reduce computational complexity and storage requirements,facilitating deployment in resource-constrained environments.Thirdly,the 3D point cloud processing pipeline should be streamlined to improve the efficiency of data acquisition,filtering,registration,and segmentation,while promoting the integration of low-cost,high-resilience vision systems into practical farming scenarios.Fourthly,specific emphasis should be placed on improving the accuracy of curved-dimensional measurements,such as chest circumference,abdominal circumference,and shank circumference,through advances in pose standardization,refined 3D segmentation strategies,and multimodal data fusion.Finally,the cross-fertilization of sheep body size measurement technologies with analogous methods for other livestock species offers a promising pathway for mutual learning and collaborative innovation,accelerating the industrialization of automated sheep morphometric systems and supporting the development of intelligent,data-driven pasture management practices. 展开更多
关键词 smart breeding computer vision image recognition three-dimensional reconstruction 2D-3D body measurement
在线阅读 下载PDF
Integrated N_(2)-Ar measurements of trace extraterrestrial samples
8
作者 Fei Su XuHang Zhang +5 位作者 ChuanTong Zhang YouJuan Li ZiHeng Liu JianNan Li HeJiu Hui HuaiYu He 《Earth and Planetary Physics》 2026年第1期22-29,共8页
As one of the major volatile components in extraterrestrial materials,nitrogen(N_(2))isotopes serve not only as tracers for the formation and evolution of the solar system,but also play a critical role in assessing pl... As one of the major volatile components in extraterrestrial materials,nitrogen(N_(2))isotopes serve not only as tracers for the formation and evolution of the solar system,but also play a critical role in assessing planetary habitability and the search for extraterrestrial life.The integrated measurement of N_(2)and argon(Ar)isotopes by using noble gas mass spectrometry represents a state-of-the-art technique for such investigations.To support the growing demands of planetary science research in China,we have developed a high-efficiency,high-precision method for the integrated analysis of N_(2)and Ar isotopes.This was achieved by enhancing gas extraction and purification systems and integrating them with a static noble gas mass spectrometer.This method enables integrated N_(2)-Ar isotope measurements on submilligram samples,significantly improving sample utilization and reducing the impact of sample heterogeneity on volatile analysis.The system integrates CO_(2)laser heating,a modular two-stage Zr-Al getter pump,and a CuO furnace-based purification process,effectively reducing background levels(N_(2)blank as low as 0.35×10^(−6)cubic centimeters at standard temperature and pressure[ccSTP]).Analytical precision is ensured through calibration with atmospheric air and CO corrections.To validate the reliability of the method,we performed N_(2)-Ar isotope analyses on the Allende carbonaceous chondrite,one of the most extensively studied meteorites internationally.The measured N_(2)concentrations range from 19.2 to 29.8 ppm,withδ15N values between−44.8‰and−33.0‰.Concentrations of 40Ar,36Ar,and 38Ar are(12.5-21.1)×10^(−6)ccSTP/g,(90.9-150.3)×10^(−9)ccSTP/g,and(19.2-30.7)×10^(−9)ccSTP/g,respectively.These values correspond to cosmic-ray exposure ages of 4.5-5.7 Ma,consistent with previous reports.Step-heating experiments further reveal distinct release patterns of N and Ar isotopes,as well as their associations with specific mineral phases in the meteorite.In summary,the combined N_(2)-Ar isotopic system offers significant advantages for tracing volatile sources in extraterrestrial materials and will provide essential analytical support for upcoming Chinese planetary missions,such as Tianwen-2. 展开更多
关键词 integrated N_(2)-Ar measurement noble gas mass spectrometer extraterrestrial samples
在线阅读 下载PDF
HALIMA:a hybrid array for lifetime measurement of neutron-rich nuclei at IMP
9
作者 Zi-Hao Jia Yong-De Fang +37 位作者 Si-Cheng Wang Wei Hua Hong-Yi Wu Guang-Xin Zhang Cen-Xi Yuan Zhi-Xuan Wang Jun-Hong Xu Jian-Hong Li Wen Liang Yu-Hong Tan Wen-Jun Pan Yu-Xuan Ren MKumar Raju Song Guo Guang-Shun Li Yun-Hua Qiang Min-Liang Liu Bing Ding Ming-Hui Huang Ning-Tao Zhang Bing-Shui Gao Peng Ma He-Run Yang Ruo-Fu Chen Hai-Xia Li Rong-Hua Li Xiu-Hua Wang Cui-Hong Chen Hai-Bo Yang Jian-Song Wang Xiao-Hui Sun Zhi-Huan Li Hui Hua Wei Wang Xin-Xing Xu Xiao-Hong Zhou Zai-Guo Gan Yu-Hu Zhang 《Nuclear Science and Techniques》 2026年第2期169-182,共14页
A new multi-detector array named HALIMA(Hybrid Array for LIfetime MeAsurement)has been developed at Lanzhou for nuclear structure studies in fission.The array comprises eight BGO-shielded High-Purity Germanium detecto... A new multi-detector array named HALIMA(Hybrid Array for LIfetime MeAsurement)has been developed at Lanzhou for nuclear structure studies in fission.The array comprises eight BGO-shielded High-Purity Germanium detectors and twenty fast Ce-doped Lanthanum Bromide[LaBr_(3)(Ce)]detectors shielded with CsI(Tl).HALIMA is further complemented by two ancillary detector systems:fission fragment(FF)detectors and β detectors.This configuration enables precise sub-nanosecond lifetime measurements using the fourfold FF/β-Ge-LaBr_(3)(Ce)-LaBr_(3)(Ce)coincidence technique.The performance and specifications of the detectors,associated electronics,and the data acquisition system are presented in detail.The advantage of FF selectivity is emphasized,which significantly enhances sensitivity to specific fission channels.Using this approach,the lifetimes of the nuclear excited states populated in the spontaneous fission of^(252)Cf were measured,showing good agreement with the established literature values. 展开更多
关键词 FFs/β-γrays coincidences SELECTIVITY Spontaneous fission LaBr_(3)(Ce) HPGE Solar cells Lifetime measurement
在线阅读 下载PDF
Measurement of emissivity with a new grey body and novel IR thermal sensor dubbed TMOS 被引量:1
10
作者 Moshe Avraham Shlomi Bouscher +2 位作者 Jonathan Nemirovsky Yael Nemirovsky 《红外与毫米波学报》 北大核心 2025年第1期17-24,共8页
The concept of emissivity has been with the scientific and engineering world since Planck formulated his blackbody radiation law more than a century ago.Nevertheless,emissivity is an elusive concept even for ex⁃perts.... The concept of emissivity has been with the scientific and engineering world since Planck formulated his blackbody radiation law more than a century ago.Nevertheless,emissivity is an elusive concept even for ex⁃perts.It is a vague and fuzzy concept for the wider community of engineers.The importance of remote sensing of temperature by measuring IR radiation has been recognized in a wide range of industrial,medical,and environ⁃mental uses.One of the major sources of errors in IR radiometry is the emissivity of the surface being measured.In real experiments,emissivity may be influenced by many factors:surface texture,spectral properties,oxida⁃tion,and aging of surfaces.While commercial blackbodies are prevalent,the much-needed grey bodies with a known emissivity,are unavailable.This study describes how to achieve a calibrated and stable emissivity with a blackbody,a perforated screen,and a reliable and linear novel IR thermal sensor,18 dubbed TMOS.The Digital TMOS is now a low-cost commercial product,it requires low power,and it has a small form factor.The method⁃ology is based on two-color measurements,with two different optical filters,with selected wavelengths conform⁃ing to the grey body definition of the use case under study.With a photochemically etched perforated screen,the effective emissivity of the screen is simply the hole density area of the surface area that emits according to the blackbody temperature radiation.The concept is illustrated with ray tracing simulations,which demonstrate the approach.Measured results are reported. 展开更多
关键词 BLACKBODY grey body graybody cavity blackbody extended area blackbody EMISSIVITY IR thermometry remote temperature measurement
在线阅读 下载PDF
High-precision large-aperture single-frame interferometric surface profile measurement method based on deep learning 被引量:1
11
作者 Liang Tang Mingzhi Han +3 位作者 Shuai Yang Ye Sun Lirong Qiu Weiqian Zhao 《International Journal of Extreme Manufacturing》 2025年第5期481-492,共12页
Large-aperture optical components are of paramount importance in domains such as integrated circuits,photolithography,aerospace,and inertial confinement fusion.However,measuring their surface profiles relies predomina... Large-aperture optical components are of paramount importance in domains such as integrated circuits,photolithography,aerospace,and inertial confinement fusion.However,measuring their surface profiles relies predominantly on the phase-shifting approach,which involves collecting multiple interferograms and imposes stringent demands on environmental stability.These issues significantly hinder its ability to achieve real-time and dynamic high-precision measurements.Therefore,this study proposes a high-precision large-aperture single-frame interferometric surface profile measurement(LA-SFISPM)method based on deep learning and explores its capability to realize dynamic measurements with high accuracy.The interferogram is matched to the phase by training the data measured using the small aperture.The consistency of the surface features of the small and large apertures is enhanced via contrast learning and feature-distribution alignment.Hence,high-precision phase reconstruction of large-aperture optical components can be achieved without using a phase shifter.The experimental results show that for the tested mirror withΦ=820 mm,the surface profile obtained from LA-SFISPM is subtracted point-by-point from the ground truth,resulting in a maximum single-point error of 4.56 nm.Meanwhile,the peak-to-valley(PV)value is 0.0758λ,and the simple repeatability of root mean square(SR-RMS)value is 0.00025λ,which aligns well with the measured results obtained by ZYGO.In particular,a significant reduction in the measurement time(reduced by a factor of 48)is achieved compared with that of the traditional phase-shifting method.Our proposed method provides an efficient,rapid,and accurate method for obtaining the surface profiles of optical components with different diameters without employing a phase-shifting approach,which is highly desired in large-aperture interferometric measurement systems. 展开更多
关键词 large-aperture optical components single-frame interferometric surface profile deep learning dynamic high-precision measurement
在线阅读 下载PDF
Channel Measurement and Analysis of Human Body Radar Cross Section in26 GHz ISAC Systems 被引量:1
12
作者 DUAN Hongyu WANG Mengyang +4 位作者 DUO Hao HE Danping MA Yihua LU Bin ZHONG Zhangdui 《ZTE Communications》 2025年第2期3-10,共8页
Radar cross section(RCS)plays a critical role in modeling target scattering characteristics and enhancing the precision of target detection and localization in integrated sensing and communication(ISAC)systems.This pa... Radar cross section(RCS)plays a critical role in modeling target scattering characteristics and enhancing the precision of target detection and localization in integrated sensing and communication(ISAC)systems.This paper investigates the human body RCS at 26 GHz via multiangle channel measurements under different clothing conditions.Based on calibrated electromagnetic(EM)parameters,the RCS characteristics of the human body in far-field conditions are analyzed using ray-tracing(RT)simulations.Some suggestions for the design of ISAC systems are also discussed.The results provide a solid theoretical foundation and practical reference for the modeling of target scattering characteristics for ISAC channels. 展开更多
关键词 channel measurement human body radar cross section integrated sensing and communication RAY-TRACING
在线阅读 下载PDF
In-flight measurement method and application research of helicopter rotor blade motion parameters 被引量:1
13
作者 Jiahong ZHENG Weizhen CHENG +2 位作者 Yan LI Shuaike JIAO Xide LI 《Chinese Journal of Aeronautics》 2025年第9期190-207,共18页
Accurate measurement of helicopter rotor motion parameters(flap,lead-lag,torsion,and azimuth angles)is essential for rotor blade design,helicopter dynamics modeling,and flight safety and health monitoring.However,the ... Accurate measurement of helicopter rotor motion parameters(flap,lead-lag,torsion,and azimuth angles)is essential for rotor blade design,helicopter dynamics modeling,and flight safety and health monitoring.However,the existing methods face challenges in testing equipment installation,calibration,and data transmission,resulting in limited reports on real-time in-flight measurements of blade motion parameters.This paper proposes a non-contact optoelectronic method based on two-dimensional position-sensitive detectors for in-flight measurement and a ground calibration system to obtain real-time rotor motion parameters during helicopter flight.The proposed method establishes the time evolution relationship of rotor motion parameters and verifies the performance of the in-flight measurement system regarding measurement resolution and accuracy through the construction of a blade motion posture experimental platform.The proposed method has been applied to the flight measurement of a medium-sized single-rotor helicopter,and the obtained results have been compared with theoretical analysis outcomes.Furthermore,this paper examines the characteristics of blade motion parameters during flight and discusses the challenges and potential solutions for measuring rotor motion parameters during helicopter flight using the proposed method. 展开更多
关键词 Blade motion parameters Flight test Helicopter rotors measurement Optical instruments Position sensitive detector
原文传递
Application of Fuzzy Inference System in Gas Turbine Engine Fault Diagnosis Against Measurement Uncertainties 被引量:1
14
作者 Shuai Ma Yafeng Wu +1 位作者 Zheng Hua Linfeng Gou 《Chinese Journal of Mechanical Engineering》 2025年第1期62-83,共22页
Robustness against measurement uncertainties is crucial for gas turbine engine diagnosis.While current research focuses mainly on measurement noise,measurement bias remains challenging.This study proposes a novel perf... Robustness against measurement uncertainties is crucial for gas turbine engine diagnosis.While current research focuses mainly on measurement noise,measurement bias remains challenging.This study proposes a novel performance-based fault detection and identification(FDI)strategy for twin-shaft turbofan gas turbine engines and addresses these uncertainties through a first-order Takagi-Sugeno-Kang fuzzy inference system.To handle ambient condition changes,we use parameter correction to preprocess the raw measurement data,which reduces the FDI’s system complexity.Additionally,the power-level angle is set as a scheduling parameter to reduce the number of rules in the TSK-based FDI system.The data for designing,training,and testing the proposed FDI strategy are generated using a component-level turbofan engine model.The antecedent and consequent parameters of the TSK-based FDI system are optimized using the particle swarm optimization algorithm and ridge regression.A robust structure combining a specialized fuzzy inference system with the TSK-based FDI system is proposed to handle measurement biases.The performance of the first-order TSK-based FDI system and robust FDI structure are evaluated through comprehensive simulation studies.Comparative studies confirm the superior accuracy of the first-order TSK-based FDI system in fault detection,isolation,and identification.The robust structure demonstrates a 2%-8%improvement in the success rate index under relatively large measurement bias conditions,thereby indicating excellent robustness.Accuracy against significant bias values and computation time are also evaluated,suggesting that the proposed robust structure has desirable online performance.This study proposes a novel FDI strategy that effectively addresses measurement uncertainties. 展开更多
关键词 Performance-based fault diagnosis Gas turbine engine Fuzzy inference system measurement uncertainty Regression and classification
在线阅读 下载PDF
Precision storage lifetime measurements of highly charged heavy ions in the CSRe storage ring using a Schottky resonator 被引量:1
15
作者 Qian Wang Xin-Liang Yan +13 位作者 Guang-Yu Zhu Shahab Sanjari Li-Jun Mao He Zhao Yuri ALitvinov Rui-Jiu Chen Meng Wang Yu-Hu Zhang You-Jin Yuan Jun-Xia Wu Hong-Yang Jiao Yue Yu Zu-Yi Chen Yin-Fang Luo 《Nuclear Science and Techniques》 2025年第1期150-160,共11页
Schottky mass spectrometry utilizing heavy-ion storage rings is a powerful technique for the precise mass and decay half-life measurements of highly charged ions.Owing to the nondestructive ion detection features of S... Schottky mass spectrometry utilizing heavy-ion storage rings is a powerful technique for the precise mass and decay half-life measurements of highly charged ions.Owing to the nondestructive ion detection features of Schottky noise detectors,the number of stored ions in the ring is determined by the peak area in the measured revolution frequency spectrum.Because of their intrinsic amplitude-frequency characteristic(AFC),Schottky detector systems exhibit varying sensitivities at different frequencies.Using low-energy electron-cooled stored ions,a new method is developed to calibrate the AFC curve of the Schottky detector system of the Experimental Cooler Storage Ring(CSRe)storage ring located in Lanzhou,China.Using the amplitude-calibrated frequency spectrum,a notable refinement was observed in the precision of both the peak position and peak area.As a result,the storage lifetimes of the electron-cooled fully ionized^(56)Fe^(26+)ions were determined with high precision at beam energies of 13.7 and 116.4 MeV/u,despite of frequency drifts during the experiment.When electron cooling was turned off,the effective vacuum condition experienced by the 116.4 MeV/u^(56)Fe^(26+)ions was determined using amplitude-calibrated spectra,revealing a value of 2×10^(−10)mbar,which is consistent with vacuum gauge readings along the CSRe ring.The method reported herein will be adapted for the next-generation storage ring of the HIAF facility under construction in Huizhou,China.It can also be adapted to other storage ring facilities worldwide to improve precision and enhance lifetime measurements using many ions in the ring. 展开更多
关键词 Lifetime measurement Schottky mass spectrometry Sensitivity response Highly charged heavy ion RESONATOR UH vacuum Nondestructive diagnostics
在线阅读 下载PDF
Correlation between the rock mass properties and maximum horizontal stress:A case study of overcoring stress measurements
16
作者 Peng Li Meifeng Cai +2 位作者 Shengjun Miao Yuan Li Yu Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS 2025年第1期39-48,共10页
Understanding the mechanical properties of the lithologies is crucial to accurately determine the horizontal stress magnitude.To investigate the correlation between the rock mass properties and maximum horizontal stre... Understanding the mechanical properties of the lithologies is crucial to accurately determine the horizontal stress magnitude.To investigate the correlation between the rock mass properties and maximum horizontal stress,the three-dimensional(3D)stress tensors at 89 measuring points determined using an improved overcoring technique in nine mines in China were adopted,a newly defined characteristic parameter C_(ERP)was proposed as an indicator for evaluating the structural properties of rock masses,and a fuzzy relation matrix was established using the information distribution method.The results indicate that both the vertical stress and horizontal stress exhibit a good linear growth relationship with depth.There is no remarkable correlation between the elastic modulus,Poisson's ratio and depth,and the distribution of data points is scattered and messy.Moreover,there is no obvious relationship between the rock quality designation(RQD)and depth.The maximum horizontal stress σ_(H) is a function of rock properties,showing a certain linear relationship with the C_(ERP)at the same depth.In addition,the overall change trend of σ_(H) determined by the established fuzzy identification method is to increase with the increase of C_(ERP).The fuzzy identification method also demonstrates a relatively detailed local relationship betweenσ_H and C_(ERP),and the predicted curve rises in a fluctuating way,which is in accord well with the measured stress data. 展开更多
关键词 overcoring stress measurements elastic modulus Poisson's ratio rock quality designation maximum horizontal stress fuzzy identification
在线阅读 下载PDF
A centroid measurement method based on 3D scanning 被引量:1
17
作者 HE Xin LI Zhen 《Journal of Measurement Science and Instrumentation》 2025年第2期186-194,共9页
The centroid coordinate serves as a critical control parameter in motion systems,including aircraft,missiles,rockets,and drones,directly influencing their motion dynamics and control performance.Traditional methods fo... The centroid coordinate serves as a critical control parameter in motion systems,including aircraft,missiles,rockets,and drones,directly influencing their motion dynamics and control performance.Traditional methods for centroid measurement often necessitate custom equipment and specialized positioning devices,leading to high costs and limited accuracy.Here,we present a centroid measurement method that integrates 3D scanning technology,enabling accurate measurement of centroid across various types of objects without the need for specialized positioning fixtures.A theoretical framework for centroid measurement was established,which combined the principle of the multi-point weighing method with 3D scanning technology.The measurement accuracy was evaluated using a designed standard component.Experimental results demonstrate that the discrepancies between the theoretical and the measured centroid of a standard component with various materials and complex shapes in the X,Y,and Z directions are 0.003 mm,0.009 mm,and 0.105 mm,respectively,yielding a spatial deviation of 0.106 mm.Qualitative verification was conducted through experimental validation of three distinct types.They confirmed the reliability of the proposed method,which allowed for accurate centroid measurements of various products without requiring positioning fixtures.This advancement significantly broadened the applicability and scope of centroid measurement devices,offering new theoretical insights and methodologies for the measurement of complex parts and systems. 展开更多
关键词 centroid measurement mass characteristic parameter 3D scanning 3D point cloud data no specialized positioning fixtures multi-point weighing method
在线阅读 下载PDF
New laser spectroscopy measurements challenge modern nuclear theories 被引量:1
18
作者 Yang Sun 《Nuclear Science and Techniques》 2025年第12期1-3,共3页
When discussing atomic nuclei,deformation is one of the most common topics.However,when we connect the concept of shape with high-precision experimental measurements,sometimes the explanation may not be as simple as w... When discussing atomic nuclei,deformation is one of the most common topics.However,when we connect the concept of shape with high-precision experimental measurements,sometimes the explanation may not be as simple as we think.A recent measurement of nuclear charge radii(Phys.Rev.Lett.134,182501(2025))challenges current nuclear ab initio models. 展开更多
关键词 nuclear ab initio models nuclear charge radii measurement nuclear charge radii physrevlett challenges atomic nuclei laser spectroscopy atomic nucleideformation deformation
在线阅读 下载PDF
Load-measurement method for floating offshore wind turbines based on a long short-term memory (LSTM) neural network 被引量:1
19
作者 Yonggang LIN Xiangheng FENG +1 位作者 Hongwei LIU Yong SUN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 2025年第5期456-470,共15页
Complicated loads encountered by floating offshore wind turbines(FOWTs)in real sea conditions are crucial for future optimization of design,but obtaining data on them directly poses a challenge.To address this issue,w... Complicated loads encountered by floating offshore wind turbines(FOWTs)in real sea conditions are crucial for future optimization of design,but obtaining data on them directly poses a challenge.To address this issue,we applied machine learning techniques to obtain hydrodynamic and aerodynamic loads of FOWTs by measuring platform motion responses and wave-elevation sequences.First,a computational fluid dynamics(CFD)simulation model of the floating platform was established based on the dynamic fluid body interaction technique and overset grid technology.Then,a long short-term memory(LSTM)neural network model was constructed and trained to learn the nonlinear relationship between the waves,platform-motion inputs,and hydrodynamic-load outputs.The optimal model was determined after analyzing the sensitivity of parameters such as sample characteristics,network layers,and neuron numbers.Subsequently,the effectiveness of the hydrodynamic load model was validated under different simulation conditions,and the aerodynamic load calculation was completed based on the D'Alembert principle.Finally,we built a hybrid-scale FOWT model,based on the software in the loop strategy,in which the wind turbine was replaced by an actuation system.Model tests were carried out in a wave basin and the results demonstrated that the root mean square errors of the hydrodynamic and aerodynamic load measurements were 4.20%and 10.68%,respectively. 展开更多
关键词 Floating offshore wind turbine(FOWT) Long short-term memory(LSTM)neural network Machine learning technique Load measurement Hybrid-scale model test
原文传递
Accurate Measurements and Error Analysis of Bi_(2)Te_(3)-Based Low-Temperature Thermoelectrics
20
作者 Jie Zhang Yixuan Ge +9 位作者 Minhua Huang Xiaohan Qin Chao Xin Linhan Wang Wenfeng Du Tianbo Lu Huaizhou Zhao Wenjie Liang Yongjun Cao Guodong Li 《Chinese Physics Letters》 2025年第5期100-116,共17页
The accurate characterization of thermoelectric properties at low temperatures is crucial for the development of high-performance thermoelectric cooling devices. While measurement errors of thermoelectric properties a... The accurate characterization of thermoelectric properties at low temperatures is crucial for the development of high-performance thermoelectric cooling devices. While measurement errors of thermoelectric properties at temperatures above room temperature have been extensively discussed, there is a lack of standard measurement protocols and error analyses for low-temperature transport properties. In this study, we present a measurement system capable of characterizing all three key thermoelectric parameters, i.e., Seebeck coefficient, electrical conductivity, and thermal conductivity, for a single sample across a temperature range of 10 K to 300 K. We investigated six representative commercial Bi_(2)Te_(3)-based samples(three N-type and three P-type). Using an error propagation model, we systematically analyzed the measurement uncertainties of the three intrinsic parameters and the resulting thermoelectric figure of merit. Our findings reveal that measurement uncertainties for both N-type and P-type Bi_(2)Te_(3)-based materials can be effectively maintained below 5% in the temperature range of 40 K to 300 K. However, the uncertainties increase to over 10% at lower temperatures, primarily due to the relatively smaller values of electrical resistivity and Seebeck coefficients in this regime. This work establishes foundational data for Bi_(2)Te_(3)-based thermoelectric materials and provides a framework for broader investigations of advanced low-temperature thermoelectrics. 展开更多
关键词 measurement system thermoelectric parameters low temperature measurements thermoelectric properties thermoelectric cooling devices error analyses standard measurement protocols characterization thermoelectric properties
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部