Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of th...Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of the needle tip and the ultrasound probe as two independent processes,lacking an integrated calibration mechanism,which often leads to cumulative errors and reduced spatial consistency.To address this challenge,we propose a joint calibration model that unifies the calibration of the surgical needle tip and the ultrasound probe within a single coordinate system.The method formulates the calibration process through a series of mathematical models and coordinate transformation models and employs a gradient descent based optimization to refine the parameters of these models.By establishing and iteratively optimizing a template coordinate system through modeling of constrained spherical motion,the proposed joint calibration model achieves submillimeter accuracy in needle tip localization.Building upon this,an N line based calibration model is developed to determine the spatial relationship between the probe and the ultrasound image plane,resulting in an average pixel deviation of only 1.2373 mm.Experimental results confirm that this unified modeling approach effectively overcomes the limitations of separate calibration schemes,significantly enhancing both precision and robustness,and providing a reliable computational model for surgical navigation systems that require high spatial accuracy without relying on ionizing radiation.展开更多
Due to the different microstructures caused by the heat source effect,welding joints exhibit significant differences in mechanical properties compared to the base material.Precise characterization of the constitutive ...Due to the different microstructures caused by the heat source effect,welding joints exhibit significant differences in mechanical properties compared to the base material.Precise characterization of the constitutive characteristics of the welded joint requires a large number of repetitive experiments,which are costly,inefficient,and have limited accuracy improvements.This paper proposes an integrated experimental-simulation-based inverse calibration method,which establishes a calibration optimization problem based on the corresponding constitutive model and a finite element calculation model built by the distribution of hardness in the weldment.Using the global tensile force-displacement curve of the MIG-welded 6005A-T6 aluminum alloy specimen and the experimental data of local deformation with time change obtained from DIC(Digital Image Correlation),the parameters involved in the constitutive models are optimized accordingly.This method can directly obtain the constitutive characteristics of the weldment under conditions of limited experiments and insufficient data.Additionally,the adaptability of the constitutive model to the calibration method and the influence of optimization results are discussed and analyzed.The results indicate that the global force-displacement response of the non-saturated Ramberg-Osgood(R-O)model is in the best agreement with that of the experimental data,and the energy error is only 2.62%,followed by the MPL model,while the saturation-based Voce model shows the largest simulation error in terms of the presented object.Furthermore,the simulation results of R-O,Voce,and MPL models in the local area are far superior to traditional fitting methods.展开更多
Haptic interaction plays an important role in the virtual reality technology,which let a person not only view the 3D virtual environment but also realistically touch the virtual environment.As a key part of haptic int...Haptic interaction plays an important role in the virtual reality technology,which let a person not only view the 3D virtual environment but also realistically touch the virtual environment.As a key part of haptic interaction,force feedback has become an essential function for the haptic interaction.Therefore,multi-dimensional force sensors are widely used in the fields of virtual reality and augmented reality.In this paper,some conventional multi-dimensional force sensors based on different measurement principles,such as resistive,capacitive,piezoelectric,are briefly introduced.Then the mechanical structures of the elastic body of multi-dimensional force sensors are reviewed.It is obvious that the performance of the multi-dimensional force sensor is mainly dependent upon the mechanical structure of elastic body.Furthermore,the calibration process of the force sensor is analyzed,and problems in calibration are discussed.Interdimensional coupling error is one of the main factors affecting the measurement precision of the multi-dimensional force sensors.Therefore,reducing or even eliminating dimensional coupling error becomes a fundamental requirement in the design of multi-dimensional force sensors,and the decoupling state-of-art of the multi-dimensional force sensors are introduced in this paper.At last,the trends and current challenges of multi-dimensional force sensing technology are proposed.展开更多
在相机和旋转模块组成的旋转扫描系统中,相机与转轴的位姿关系对于后续数据融合至关重要。现有方法通常需借助辅助传感器来建立转轴与相机的位姿关系。为降低标定成本,本文提出一种基于ChArUco(Chess Augmented Reality University of C...在相机和旋转模块组成的旋转扫描系统中,相机与转轴的位姿关系对于后续数据融合至关重要。现有方法通常需借助辅助传感器来建立转轴与相机的位姿关系。为降低标定成本,本文提出一种基于ChArUco(Chess Augmented Reality University of Córdoba)标定板的转轴位姿标定方法。利用ChArUco标定板图像解算不同转角下的相机光心坐标并拟合光心轨迹,根据轨迹中心可确定转轴所在位置。建立了旋转系统的数学模型,推导了在世界坐标系下转轴位姿的数学表达式,并基于旋转系统的空间约束构建联合优化,计算相机和转轴间最佳位姿。利用所提出方法进行旋转相机系统标定实验,实验结果表明:标定后的转轴与相机光轴夹角的平均绝对误差为0.036°,标定结果能有效消除全景拼接时的重影现象,验证了所提出方法的准确性和可行性。展开更多
The problem of joint eigenvalue estimation for the non-defective commuting set of matrices A is addressed. A procedure revealing the joint eigenstructure by simultaneous diagonalization of. A with simultaneous Schur d...The problem of joint eigenvalue estimation for the non-defective commuting set of matrices A is addressed. A procedure revealing the joint eigenstructure by simultaneous diagonalization of. A with simultaneous Schur decomposition (SSD) and balance procedure alternately is proposed for performance considerations and also for overcoming the convergence difficulties of previous methods based only on simultaneous Schur form and unitary transformations, it is shown that the SSD procedure can be well incorporated with the balancing algorithm in a pingpong manner, i. e., each optimizes a cost function and at the same time serves as an acceleration procedure for the other. Under mild assumptions, the convergence of the two cost functions alternately optimized, i. e., the norm of A and the norm of the left-lower part of A is proved. Numerical experiments are conducted in a multi-dimensional harmonic retrieval application and suggest that the presented method converges considerably faster than the methods based on only unitary transformation for matrices which are not near to normality.展开更多
基金Support by Sichuan Science and Technology Program[2023YFSY0026,2023YFH0004].
文摘Accurate calibration of surgical instruments and ultrasound probes is essential for achieving high precision in image guided minimally invasive procedures.However,existing methods typically treat the calibration of the needle tip and the ultrasound probe as two independent processes,lacking an integrated calibration mechanism,which often leads to cumulative errors and reduced spatial consistency.To address this challenge,we propose a joint calibration model that unifies the calibration of the surgical needle tip and the ultrasound probe within a single coordinate system.The method formulates the calibration process through a series of mathematical models and coordinate transformation models and employs a gradient descent based optimization to refine the parameters of these models.By establishing and iteratively optimizing a template coordinate system through modeling of constrained spherical motion,the proposed joint calibration model achieves submillimeter accuracy in needle tip localization.Building upon this,an N line based calibration model is developed to determine the spatial relationship between the probe and the ultrasound image plane,resulting in an average pixel deviation of only 1.2373 mm.Experimental results confirm that this unified modeling approach effectively overcomes the limitations of separate calibration schemes,significantly enhancing both precision and robustness,and providing a reliable computational model for surgical navigation systems that require high spatial accuracy without relying on ionizing radiation.
基金Supported by National Natural Science Foundation of China(Grant Nos.52202431,52172353)Talent Fund of Beijing Jiaotong University of China(Grant No.2024XKRC044).
文摘Due to the different microstructures caused by the heat source effect,welding joints exhibit significant differences in mechanical properties compared to the base material.Precise characterization of the constitutive characteristics of the welded joint requires a large number of repetitive experiments,which are costly,inefficient,and have limited accuracy improvements.This paper proposes an integrated experimental-simulation-based inverse calibration method,which establishes a calibration optimization problem based on the corresponding constitutive model and a finite element calculation model built by the distribution of hardness in the weldment.Using the global tensile force-displacement curve of the MIG-welded 6005A-T6 aluminum alloy specimen and the experimental data of local deformation with time change obtained from DIC(Digital Image Correlation),the parameters involved in the constitutive models are optimized accordingly.This method can directly obtain the constitutive characteristics of the weldment under conditions of limited experiments and insufficient data.Additionally,the adaptability of the constitutive model to the calibration method and the influence of optimization results are discussed and analyzed.The results indicate that the global force-displacement response of the non-saturated Ramberg-Osgood(R-O)model is in the best agreement with that of the experimental data,and the energy error is only 2.62%,followed by the MPL model,while the saturation-based Voce model shows the largest simulation error in terms of the presented object.Furthermore,the simulation results of R-O,Voce,and MPL models in the local area are far superior to traditional fitting methods.
基金Supported by Natural Science Foundation of China(U1713210).
文摘Haptic interaction plays an important role in the virtual reality technology,which let a person not only view the 3D virtual environment but also realistically touch the virtual environment.As a key part of haptic interaction,force feedback has become an essential function for the haptic interaction.Therefore,multi-dimensional force sensors are widely used in the fields of virtual reality and augmented reality.In this paper,some conventional multi-dimensional force sensors based on different measurement principles,such as resistive,capacitive,piezoelectric,are briefly introduced.Then the mechanical structures of the elastic body of multi-dimensional force sensors are reviewed.It is obvious that the performance of the multi-dimensional force sensor is mainly dependent upon the mechanical structure of elastic body.Furthermore,the calibration process of the force sensor is analyzed,and problems in calibration are discussed.Interdimensional coupling error is one of the main factors affecting the measurement precision of the multi-dimensional force sensors.Therefore,reducing or even eliminating dimensional coupling error becomes a fundamental requirement in the design of multi-dimensional force sensors,and the decoupling state-of-art of the multi-dimensional force sensors are introduced in this paper.At last,the trends and current challenges of multi-dimensional force sensing technology are proposed.
文摘在相机和旋转模块组成的旋转扫描系统中,相机与转轴的位姿关系对于后续数据融合至关重要。现有方法通常需借助辅助传感器来建立转轴与相机的位姿关系。为降低标定成本,本文提出一种基于ChArUco(Chess Augmented Reality University of Córdoba)标定板的转轴位姿标定方法。利用ChArUco标定板图像解算不同转角下的相机光心坐标并拟合光心轨迹,根据轨迹中心可确定转轴所在位置。建立了旋转系统的数学模型,推导了在世界坐标系下转轴位姿的数学表达式,并基于旋转系统的空间约束构建联合优化,计算相机和转轴间最佳位姿。利用所提出方法进行旋转相机系统标定实验,实验结果表明:标定后的转轴与相机光轴夹角的平均绝对误差为0.036°,标定结果能有效消除全景拼接时的重影现象,验证了所提出方法的准确性和可行性。
基金The National Natural Science Foundation of China(No.60572072,60496311),the National High Technology Researchand Development Program of China (863Program ) ( No.2003AA123310),the International Cooperation Project on Beyond 3G Mobile of China (No.2005DFA10360).
文摘The problem of joint eigenvalue estimation for the non-defective commuting set of matrices A is addressed. A procedure revealing the joint eigenstructure by simultaneous diagonalization of. A with simultaneous Schur decomposition (SSD) and balance procedure alternately is proposed for performance considerations and also for overcoming the convergence difficulties of previous methods based only on simultaneous Schur form and unitary transformations, it is shown that the SSD procedure can be well incorporated with the balancing algorithm in a pingpong manner, i. e., each optimizes a cost function and at the same time serves as an acceleration procedure for the other. Under mild assumptions, the convergence of the two cost functions alternately optimized, i. e., the norm of A and the norm of the left-lower part of A is proved. Numerical experiments are conducted in a multi-dimensional harmonic retrieval application and suggest that the presented method converges considerably faster than the methods based on only unitary transformation for matrices which are not near to normality.