Ultrafast electron sources, which enable high spatiotemporal resolution in time-resolved electron microscopy and scanning probe microscopy, are receiving increased attention. The most widely used method for achieving ...Ultrafast electron sources, which enable high spatiotemporal resolution in time-resolved electron microscopy and scanning probe microscopy, are receiving increased attention. The most widely used method for achieving ultrafast electron sources involves irradiating metal tips by ultrashort laser pulses, causing electron beam emission via the photoelectric effect [including photon-driven(quantum) or field-driven(classical) emission]. However, the thermionic electrons emission process due to the heating effect of ultrashort lasers, particularly its dynamic aspects, has rarely been addressed in previous studies. In this paper, we improved the signal-to-noise ratio of a two-pulse correlation measurement on the tip electron emission by nearly two orders of magnitude using a delay time modulation method. This allowed us to obtain information on the temperature evolution of hot electrons and phonons in a non-equilibrium state, and to extract characteristic time scales for electron-phonon and phonon-phonon scattering. Our findings indicate that the thermionic electrons emission, unlike the instantaneous photoelectric effect, causes electron emission to lag behind the laser pulse by tens of picoseconds, thus significantly affecting the detection of ultrafast dynamics of samples. Furthermore, such a lagging effect was found to be sensitive to the local structure of the metal tip, offering new insights into the improved design of ultrafast electron sources.展开更多
In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,t...In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,the characteristics of hollow-cathode discharge and electron beam characterization under pulsed high voltage drive are studied experimentally and discussed by discharge characteristics and analyses of waveform details,respectively.The validation experiments indicate that the pulsed high voltage supply significantly improves the frequency and stability of the discharge,which provides a new solution for the realization of a high-frequency,high-energy electron beam source.The peak current amplitude in the high-energy electron beam increases from 6.2 A to 79.6 A,which indicates the pulsed power mode significantly improves the electron beam performance.Besides,increasing the capacitance significantly affects the highcurrent,lower-energy electron beam more than the high-energy electron beam.展开更多
A new electron impact storage ion source has been designed for time of flight mass spectrometers with a high mass resolving power and high sensitivity. Because of the storage and compressing focus of the source, the o...A new electron impact storage ion source has been designed for time of flight mass spectrometers with a high mass resolving power and high sensitivity. Because of the storage and compressing focus of the source, the overall performance of the instrument has been improved greatly with a mass resolving power up to 3 500. The conditions of the second order of the focus are given and the storage ability is proved. The competer simulations and experiment results are given, too.展开更多
Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative s...Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative system concepts in X-ray and computer tomography. This paper proposes a novel electron beam focusing, shaping,and deflection electron gun for distributed X-ray sources.The electron gun uses a dispenser cathode as an electron emitter, a mesh grid to control emission current, and two electrostatic lenses for beam shaping, focusing, and deflection. Novel focusing and deflecting electrodes were designed to increase the number of focal spots in the distributed source. Two identical half-rectangle opening electrodes are controlled by adjusting the potential of the two electrodes to control the electron beam trajectory, and then, multifocal spots are obtained on the anode target. The electron gun can increase the spatial density of the distributed X-ray sources, thereby improving the image quality. The beam experimental results show that the focal spot sizes of the deflected(deflected amplitude 10.5 mm)and non-deflected electron beams at full width at half maximum are 0.80 mm 90.50 mm and 0.55 mm 90.40 mm, respectively(anode voltage 160 kV; beam current 30 mA). The imaging experimental results demonstrate the excellent spatial resolution and time resolution of an imaging system built with the sources, which has an excellent imaging effect on a field-programmable gate array chip and a rotating metal disk.展开更多
A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron...A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron source. Simulation with Ansoft Maxwell 12 is carried out to analyze the electric field distribution within the IMS, and to offer the basis and foundation for analyzing the measurement results. The measurement results of the quantities of electrons show that when the drift electric field strength and the ring inner diameter rise, both the number of ef- fective electrons and the effective electron rate are increased. When the discharge voltage becomes stronger, the number of effective electrons goes up while the effective electron rate goes down. In light of the simulation results, mechanisms underlying the effects of drift electric field strength, ring inner diameter, and discharge voltage on the effective electron number and effective electron rate are discussed. These will make great sense for designing negative ion mode IMS using the needle-ring pulsed corona discharge as the electron source.展开更多
In this paper, the common heat source model of point and linear heat source in the numerical simulation of electron beam welding (EBW) were summarized and introduced. The combined point-linear heat source model was ...In this paper, the common heat source model of point and linear heat source in the numerical simulation of electron beam welding (EBW) were summarized and introduced. The combined point-linear heat source model was brought forward and to simulate the welding temperature fields of EBW and predicting the weld shape. The model parameters were put forward and regulated in the combined model, which included the ratio of point heat source to linear heat source Qpr and the distribution of linear heat source Lr. Based on the combined model, the welding temperature fields of EBW were investigated. The results show that the predicted weld shapes are conformable to those of the actual, the temperature fields are reasonable and correct by simulating with combined point-linear heat source model and the typical weld shapes are gained.展开更多
The ion source of the electron cyclotron resonance ion thruster (ECRIT) extracts ions from its ECR plasma to generate thrust, and has the property of low gas consumption (2 seem, standard-state cubic centimeter per...The ion source of the electron cyclotron resonance ion thruster (ECRIT) extracts ions from its ECR plasma to generate thrust, and has the property of low gas consumption (2 seem, standard-state cubic centimeter per minute) and high durability. Due to the indispensable effects of the primary electron in gas discharge, it is important to experimentally clarify the electron energy structure within the ion source of the ECRIT through analyzing the electron energy distribution function (EEDF) of the plasma inside the thruster. In this article the Langmuir probe diagnosing method was used to diagnose the EEDF, from which the effective electron temperature, plasma density and the electron energy probability function (EEPF) were deduced. The experimental results show that the magnetic field influences the curves of EEDF and EEPF and make the effective plasma parameter nonuniform. The diagnosed electron temperature and density from sample points increased from 4 eV/2 ×10^16 m-3 to 10 eV/4×10^16 m-3 with increasing distances from both the axis and the screen grid of the ion source. Electron temperature and density peaking near the wall coincided with the discharge process. However, a double Maxwellian electron distribution was unexpectedly observed at the position near the axis of the ion source and about 30 mm from the screen grid. Besides, the double Maxwellian electron distribution was more likely to emerge at high power and a low gas flow rate. These phenomena were believed to relate to the arrangements of the gas inlets and the magnetic field where the double Maxwellian electron distribution exits. The results of this research may enhance the understanding of the plasma generation process in the ion source of this type and help to improve its performance.展开更多
The effects of two different external carbon sources (acetate and ethanol) and electron acceptors (dissolved oxygen, nitrate, and nitrite) were investigated under aerobic and anoxic conditions with non-acclimated ...The effects of two different external carbon sources (acetate and ethanol) and electron acceptors (dissolved oxygen, nitrate, and nitrite) were investigated under aerobic and anoxic conditions with non-acclimated process bi- omass from a full-scale biological nutrient removal-activated sludge system. When acetate was added as an external carbon source, phosphate release was observed even in the presence of electron acceptors. The release rates were 1.7, 7.8, and 3.5 mg P/(g MLVSS.h) (MLVSS: mixed liquor volatile suspended solids), respectively, for dissolved oxygen, nitrate, and nitrite. In the case of ethanol, no phosphate release was observed in the presence of electron acceptors. Results of the experiments with nitrite showed that approximately 25 mg NO2-N/L of nitrite inhibited anoxic phosphorus uptake regardless of the concentration of the tested external carbon sources. Furthermore, higher deni- trification rates were obtained with acetate (1.4 and 0.8 mg N/(g MLVSS.h)) compared to ethanol (1.1 and 0.7 mg N/ (g MLVSS.h)) for both anoxic electron acceptors (nitrate and nitrite).展开更多
In recent years,the gap between the supply and demand of medical radioisotopes has increased,necessitating new methods for producing medical radioisotopes.Photonuclear reactions based on gamma sources have unique adva...In recent years,the gap between the supply and demand of medical radioisotopes has increased,necessitating new methods for producing medical radioisotopes.Photonuclear reactions based on gamma sources have unique advantages in terms of producing high specific activity and innovative medical radioisotopes.However,the lack of experimental data on reaction cross sections for photonuclear reactions of medical radioisotopes of interest has severely limited the development and production of photonuclear transmutation medical radioisotopes.In this study,the entire process of the generation,decay,and measurement of medical radioisotopes was simulated using online gamma activation and offline gamma measurements combined with a shielding gamma-ray spectrometer.Based on a quasi-monochromatic gamma beam from the Shanghai Laser Electron Gamma Source(SLEGS),the feasibility of this measurement of production cross section for surveyed medi-cal radioisotopes was simulated,and specific solutions for measuring medical radioisotopes with ultra-low production cross sections were provided.The feasibility of this method for high-precision measurements of the reaction cross section of medical radioisotopes was demonstrated.展开更多
A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconductin...A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional supercon- ducting ECR magnetic structure, the SEC17AL Ⅱ includes three superconducting solenoid coils' that are located inside the superconducting sextupoles. The SECRAL Ⅱ can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL Ⅱ generating its self field of -8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at 〈200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL Ⅱ structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the based on our analysis, the stresses and deformations optimized. strains developments of a sextupole is reported. Finally, for its assembly of each SECRAL Ⅱ coil will be further展开更多
A new GaAs(100) spin polarized electron source with an optical polarimeter, which is employed in the field of polarized electron and gas atom collision, is presented in detail. The apparatus is passive-magnetic-shie...A new GaAs(100) spin polarized electron source with an optical polarimeter, which is employed in the field of polarized electron and gas atom collision, is presented in detail. The apparatus is passive-magnetic-shielded by a box and a cylinder made of nickel-iron-molybdenum soft magnetic alloy without Helmholtz coil arrangement. And a uniformly distributed residual magnetic field of less than 5 × 10^-7T is obtained near the collision area. The spin polarized electron beam is transmitted and focused onto collision point from photocathode by a set of electron optics with more than 25% transmission 95 cm distance through an 1 mm diameter aperture. Construction and operation of the apparatus, such as vacuum and magnetic shielding system, photocathode, laser optics, electron optics and polarimeter are discussed. The polarization of the spin polarized electron beam is determined to be 30.8 ±3.5% measured with a He optical polarimeter.展开更多
We report a new design of microwave source for X-band electron paramagnetic resonance spectrometer.The microwave source is equipped with a digital automatic frequency control circuit.The parameters of the digital auto...We report a new design of microwave source for X-band electron paramagnetic resonance spectrometer.The microwave source is equipped with a digital automatic frequency control circuit.The parameters of the digital automatic frequency control circuit can be flexibly configured for different experimental conditions,such as the input powers or the quality factors of the resonator.The configurability makes the microwave source universally compatible and greatly extends its application.To demonstrate the ability of adapting to various experimental conditions,the microwave source is tested by varying the input powers and the quality factors of the resonator.A satisfactory phase noise as low as-135 d Bc/Hz at 100-k Hz offset from the center frequency is achieved,due to the use of a phase-locked dielectric resonator oscillator and a direct digital synthesizer.Continuous-wave electron paramagnetic resonance experiments are conducted to examine the performance of the microwave source.The outstanding performance shows a prospect of wide applications of the microwave source in numerous fields of science.展开更多
A new kind of electron source, the photoemissive monoenergetic electron source has been invented for calibrating the beta--magnetic spectrometer. It produceselectrons in the form of simulating a radioactive monoenerge...A new kind of electron source, the photoemissive monoenergetic electron source has been invented for calibrating the beta--magnetic spectrometer. It produceselectrons in the form of simulating a radioactive monoenergetic electron source andcan be made in any shape and size according tO the demands of experimentS. In thispaper, the principles and basic constructions of the photoemissive monoenergeticelectron source are described, the resultS of calibrating our 2’l’x bead--magneticspectrometer with a single strip arc shaped photoemissive monoenergetic electronsource are listed, a new way for determining resolution function of experimentslsystem in the research of neutrino rest mass has been posed and one of its actualapplications is also given.展开更多
Negative-ion-based neutral beam injection(NNBI)at high energy is still a potential heating and current drive method for future large-scale fusion reactors.One feature of the negative ion source is that the electrons a...Negative-ion-based neutral beam injection(NNBI)at high energy is still a potential heating and current drive method for future large-scale fusion reactors.One feature of the negative ion source is that the electrons are also accelerated with the negative ions in the accelerator.In addition to the electrons co-extracted from the source plasma,electrons are inevitably generated in the main acceleration stage due to the stripping loss of negative ions or the ionization of background gas.Many of these accelerated electrons can be ejected by the negative ion source,which poses a risk for the downstream components in the beamline of the NNBI system,especially the thermosensitive cryopumps.To prevent the ejected electrons from impacting the cryopumps,electron dumps have been designed for the beamline of the China Fusion Engineering Test Reactor(CFETR)advance neutral beam equipment(CANBE).Using a selfconsistent model of the negative ion accelerator,the generation and motion of the ejected electrons were simulated for different negative ion sources to be tested on the CANBE.Based on the orbits of the ejected electrons,a set of fixed and movable electron dumps was designed to be placed in front of the neutralizer inside the CANBE beamline.The effects of the electron dumps were quantitatively analyzed.展开更多
Aqueous Ni-Zn microbatteries are safe,reliable and inexpensive but notoriously suffer from inadequate energy and power densities.Herein,we present a novel mechanism of superoxide-activated Ni substrate that realizes t...Aqueous Ni-Zn microbatteries are safe,reliable and inexpensive but notoriously suffer from inadequate energy and power densities.Herein,we present a novel mechanism of superoxide-activated Ni substrate that realizes the redox reaction featuring three-electron transfers(Ni↔Ni3+).The superoxide activates the direct redox reaction between Ni substrate and KNiO_(2)by lowering the reaction Gibbs free energy,supported by in-situ Raman and density functional theory simulations.The prepared chronopotentiostatic superoxidation-activated Ni(CPS-Ni)electrodes exhibit an ultrahigh capacity of 3.21 mAh cm^(-2)at the current density of 5 mA cm^(-2),nearly 8 times that of traditional one-electron processes electrodes.Even under the ultrahigh 200 mA cm^(-2)current density,the CPS-Ni electrodes show 86.4%capacity retention with a Columbic efficiency of 99.2%after 10,000 cycles.The CPS-Ni||Zn microbattery achieves an exceptional energy density of 6.88 mWh cm^(-2)and power density of 339.56 mW cm^(-2).Device demonstration shows that the power source can continuously operate for more than 7 days in powering the sensing and computation intensive practical application of photoplethysmographic waveform monitoring.This work paves the way to the development of multi-electron transfer mechanisms for advanced aqueous Ni-Zn batteries with high capacity and long lifetime.展开更多
Quasistationary discharge mode setting in the explosive-emission sources is related to the saturation of the cathode plasma emissive ability resulting in the decrease of the velocity of plasma propagation into the int...Quasistationary discharge mode setting in the explosive-emission sources is related to the saturation of the cathode plasma emissive ability resulting in the decrease of the velocity of plasma propagation into the interelectrode gap. It was shoran previously that the electron beam space charge providing the current rise slowing-down is of great importance in the process of the discharge mode stabilization. The paper considers a possibility of the discharge protraction at the expense of decrease of the ion charge order in the plasma composition and application of the directed plasma flows. The data concerning obtainig of micro- and millisecond electron beams in the explosive-emission sources are presented as well.展开更多
Breakdown formation in the explosive-emission sources is related to the interelectrode gap filling with the cathode and anode plasma generated at the anode and in the gap under the beam influence. Under conditions of ...Breakdown formation in the explosive-emission sources is related to the interelectrode gap filling with the cathode and anode plasma generated at the anode and in the gap under the beam influence. Under conditions of saturation of the cathode plasma emissive ability as well as when the measures on the emission boundary stabilization are taken, the anode plasma has the deciding part in the formation of the electron source breakdown. The paper presents the results of the anode plasma investigations obtained to solve the problem of the electron beam length increase in the explosive-emission sources. The data concerning the gas release from the anode, the mechanism of the anode plasma formation and the anode plasma influence on the parameters of the generated electron beam are presented as well.展开更多
Formation of a quasi-stationary discharge or quasi-stationary emission mode in the explosive-emission electron sources is related to the current limitation resulting from the emissive ability saturation of cathode pla...Formation of a quasi-stationary discharge or quasi-stationary emission mode in the explosive-emission electron sources is related to the current limitation resulting from the emissive ability saturation of cathode plasma with its expansion. The paper shows that in the process of the discharge current stabilization in the explosive-emission sources with the point- or blade-type emitters the essential role belongs to the electron beam space charge. Availability of the space charge results in limitation of the current growth velocity at the initial discharge phase and, hence, restricts the emissive ability of the cathode plasma and contributes to its saturation. In the vacuum diodes with multiemitter cathodes, the space charge availability increases the cathode operation stability and can provide obtaining of quasi-stationary beam current values or close to them resulting in formation of a plasma emission surface at the cathode close to the continuous one.展开更多
Since loading complexand dynamic heat source is a difficult job during welding simulation process, methods are studied to add the load automatically. Firstly, an expert module for selecting welding heat source model i...Since loading complexand dynamic heat source is a difficult job during welding simulation process, methods are studied to add the load automatically. Firstly, an expert module for selecting welding heat source model is founded based on simulation knowledge and experienc Secondly, a method named as "High order routine" is presented, which creates subroutines of 3D dynamic heat source m'od, el for user. Then an automated tool is presented to load the welding heat source boundary based on Marc software. The tool uses Marc command file to robustly achieve the process. At last, an electron beam welding heat model is presented to express the "toading method.展开更多
基金supported by the National Key R&D Program under Grant No.2021YFA1400500the National Natural Science Foundation of China under Grant No.22273029+1 种基金the New Cornerstone Science Foundation through the New Cornerstone Investigator Program under Grant No.NCI202303 and the XPLORER PRIZEthe Beijing Outstanding Young Scientist Program under Grant No.JWZQ20240101002。
文摘Ultrafast electron sources, which enable high spatiotemporal resolution in time-resolved electron microscopy and scanning probe microscopy, are receiving increased attention. The most widely used method for achieving ultrafast electron sources involves irradiating metal tips by ultrashort laser pulses, causing electron beam emission via the photoelectric effect [including photon-driven(quantum) or field-driven(classical) emission]. However, the thermionic electrons emission process due to the heating effect of ultrashort lasers, particularly its dynamic aspects, has rarely been addressed in previous studies. In this paper, we improved the signal-to-noise ratio of a two-pulse correlation measurement on the tip electron emission by nearly two orders of magnitude using a delay time modulation method. This allowed us to obtain information on the temperature evolution of hot electrons and phonons in a non-equilibrium state, and to extract characteristic time scales for electron-phonon and phonon-phonon scattering. Our findings indicate that the thermionic electrons emission, unlike the instantaneous photoelectric effect, causes electron emission to lag behind the laser pulse by tens of picoseconds, thus significantly affecting the detection of ultrafast dynamics of samples. Furthermore, such a lagging effect was found to be sensitive to the local structure of the metal tip, offering new insights into the improved design of ultrafast electron sources.
基金supported by National Natural Science Foundation of China(No.12102099)the National Key R&D Program of China(No.2021YFC2202700)the Outstanding Academic Leader Project of Shanghai(Youth)(No.23XD1421700),respectively。
文摘In this study,a pulsed,high voltage driven hollow-cathode electron beam sources through an optical trigger is designed with characteristics of simple structure,low cost,and easy triggering.To validate the new design,the characteristics of hollow-cathode discharge and electron beam characterization under pulsed high voltage drive are studied experimentally and discussed by discharge characteristics and analyses of waveform details,respectively.The validation experiments indicate that the pulsed high voltage supply significantly improves the frequency and stability of the discharge,which provides a new solution for the realization of a high-frequency,high-energy electron beam source.The peak current amplitude in the high-energy electron beam increases from 6.2 A to 79.6 A,which indicates the pulsed power mode significantly improves the electron beam performance.Besides,increasing the capacitance significantly affects the highcurrent,lower-energy electron beam more than the high-energy electron beam.
文摘A new electron impact storage ion source has been designed for time of flight mass spectrometers with a high mass resolving power and high sensitivity. Because of the storage and compressing focus of the source, the overall performance of the instrument has been improved greatly with a mass resolving power up to 3 500. The conditions of the second order of the focus are given and the storage ability is proved. The competer simulations and experiment results are given, too.
文摘Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative system concepts in X-ray and computer tomography. This paper proposes a novel electron beam focusing, shaping,and deflection electron gun for distributed X-ray sources.The electron gun uses a dispenser cathode as an electron emitter, a mesh grid to control emission current, and two electrostatic lenses for beam shaping, focusing, and deflection. Novel focusing and deflecting electrodes were designed to increase the number of focal spots in the distributed source. Two identical half-rectangle opening electrodes are controlled by adjusting the potential of the two electrodes to control the electron beam trajectory, and then, multifocal spots are obtained on the anode target. The electron gun can increase the spatial density of the distributed X-ray sources, thereby improving the image quality. The beam experimental results show that the focal spot sizes of the deflected(deflected amplitude 10.5 mm)and non-deflected electron beams at full width at half maximum are 0.80 mm 90.50 mm and 0.55 mm 90.40 mm, respectively(anode voltage 160 kV; beam current 30 mA). The imaging experimental results demonstrate the excellent spatial resolution and time resolution of an imaging system built with the sources, which has an excellent imaging effect on a field-programmable gate array chip and a rotating metal disk.
基金supported by National Natural Science Foundation of China(No.51077062)
文摘A simple negative ion mobility spectrometer (IMS) is designed and used to investi- gate the factors that influence the number and efficiency of electrons generated by the needle-ring pulsed corona discharge electron source. Simulation with Ansoft Maxwell 12 is carried out to analyze the electric field distribution within the IMS, and to offer the basis and foundation for analyzing the measurement results. The measurement results of the quantities of electrons show that when the drift electric field strength and the ring inner diameter rise, both the number of ef- fective electrons and the effective electron rate are increased. When the discharge voltage becomes stronger, the number of effective electrons goes up while the effective electron rate goes down. In light of the simulation results, mechanisms underlying the effects of drift electric field strength, ring inner diameter, and discharge voltage on the effective electron number and effective electron rate are discussed. These will make great sense for designing negative ion mode IMS using the needle-ring pulsed corona discharge as the electron source.
基金co-supported by the National Basic Research Program (No.61362)the National Natural Science Foundation of China(No. 50935008 and 10902113)Science Foundation of Aeronautics (No. 2010ZE25006)
文摘In this paper, the common heat source model of point and linear heat source in the numerical simulation of electron beam welding (EBW) were summarized and introduced. The combined point-linear heat source model was brought forward and to simulate the welding temperature fields of EBW and predicting the weld shape. The model parameters were put forward and regulated in the combined model, which included the ratio of point heat source to linear heat source Qpr and the distribution of linear heat source Lr. Based on the combined model, the welding temperature fields of EBW were investigated. The results show that the predicted weld shapes are conformable to those of the actual, the temperature fields are reasonable and correct by simulating with combined point-linear heat source model and the typical weld shapes are gained.
基金supported by National Natural Science Foundation of China(No.11475137)
文摘The ion source of the electron cyclotron resonance ion thruster (ECRIT) extracts ions from its ECR plasma to generate thrust, and has the property of low gas consumption (2 seem, standard-state cubic centimeter per minute) and high durability. Due to the indispensable effects of the primary electron in gas discharge, it is important to experimentally clarify the electron energy structure within the ion source of the ECRIT through analyzing the electron energy distribution function (EEDF) of the plasma inside the thruster. In this article the Langmuir probe diagnosing method was used to diagnose the EEDF, from which the effective electron temperature, plasma density and the electron energy probability function (EEPF) were deduced. The experimental results show that the magnetic field influences the curves of EEDF and EEPF and make the effective plasma parameter nonuniform. The diagnosed electron temperature and density from sample points increased from 4 eV/2 ×10^16 m-3 to 10 eV/4×10^16 m-3 with increasing distances from both the axis and the screen grid of the ion source. Electron temperature and density peaking near the wall coincided with the discharge process. However, a double Maxwellian electron distribution was unexpectedly observed at the position near the axis of the ion source and about 30 mm from the screen grid. Besides, the double Maxwellian electron distribution was more likely to emerge at high power and a low gas flow rate. These phenomena were believed to relate to the arrangements of the gas inlets and the magnetic field where the double Maxwellian electron distribution exits. The results of this research may enhance the understanding of the plasma generation process in the ion source of this type and help to improve its performance.
基金Project supported by the European Regional Development Fund within the Framework of the Innovative Economy Operational Program 2007-2013(No.UDA-POIG.01.03.01-22-140/09-04)the CARbon BALAncing for Nutrient Control in Wastewater Treatment(CARBALA)(No.PIRSES-GA-2011-295176)the National Water Pollution Control and Management of Science and Technology in China(No.2015ZX07218001)
文摘The effects of two different external carbon sources (acetate and ethanol) and electron acceptors (dissolved oxygen, nitrate, and nitrite) were investigated under aerobic and anoxic conditions with non-acclimated process bi- omass from a full-scale biological nutrient removal-activated sludge system. When acetate was added as an external carbon source, phosphate release was observed even in the presence of electron acceptors. The release rates were 1.7, 7.8, and 3.5 mg P/(g MLVSS.h) (MLVSS: mixed liquor volatile suspended solids), respectively, for dissolved oxygen, nitrate, and nitrite. In the case of ethanol, no phosphate release was observed in the presence of electron acceptors. Results of the experiments with nitrite showed that approximately 25 mg NO2-N/L of nitrite inhibited anoxic phosphorus uptake regardless of the concentration of the tested external carbon sources. Furthermore, higher deni- trification rates were obtained with acetate (1.4 and 0.8 mg N/(g MLVSS.h)) compared to ethanol (1.1 and 0.7 mg N/ (g MLVSS.h)) for both anoxic electron acceptors (nitrate and nitrite).
基金supported by the Strategic Priority Research Program of the CAS(No.XDB34030000)National Natural Science Foundation of China(No.11975210 and No.U1832129)+1 种基金National Key Research and Development Program of China(No.2022YFA1602404)Youth Innovation Promotion Association CAS(No.2017309).
文摘In recent years,the gap between the supply and demand of medical radioisotopes has increased,necessitating new methods for producing medical radioisotopes.Photonuclear reactions based on gamma sources have unique advantages in terms of producing high specific activity and innovative medical radioisotopes.However,the lack of experimental data on reaction cross sections for photonuclear reactions of medical radioisotopes of interest has severely limited the development and production of photonuclear transmutation medical radioisotopes.In this study,the entire process of the generation,decay,and measurement of medical radioisotopes was simulated using online gamma activation and offline gamma measurements combined with a shielding gamma-ray spectrometer.Based on a quasi-monochromatic gamma beam from the Shanghai Laser Electron Gamma Source(SLEGS),the feasibility of this measurement of production cross section for surveyed medi-cal radioisotopes was simulated,and specific solutions for measuring medical radioisotopes with ultra-low production cross sections were provided.The feasibility of this method for high-precision measurements of the reaction cross section of medical radioisotopes was demonstrated.
基金Supported by the National Natural Science Foundation of China under Grant No 11302225the China Postdoctoral Science Foundation under Grant Nos 2014M560820 and 2015T81071
文摘A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional supercon- ducting ECR magnetic structure, the SEC17AL Ⅱ includes three superconducting solenoid coils' that are located inside the superconducting sextupoles. The SECRAL Ⅱ can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL Ⅱ generating its self field of -8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at 〈200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL Ⅱ structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the based on our analysis, the stresses and deformations optimized. strains developments of a sextupole is reported. Finally, for its assembly of each SECRAL Ⅱ coil will be further
基金Project supported by the National Natural Science Foundation of China (Grant No 10134010).
文摘A new GaAs(100) spin polarized electron source with an optical polarimeter, which is employed in the field of polarized electron and gas atom collision, is presented in detail. The apparatus is passive-magnetic-shielded by a box and a cylinder made of nickel-iron-molybdenum soft magnetic alloy without Helmholtz coil arrangement. And a uniformly distributed residual magnetic field of less than 5 × 10^-7T is obtained near the collision area. The spin polarized electron beam is transmitted and focused onto collision point from photocathode by a set of electron optics with more than 25% transmission 95 cm distance through an 1 mm diameter aperture. Construction and operation of the apparatus, such as vacuum and magnetic shielding system, photocathode, laser optics, electron optics and polarimeter are discussed. The polarization of the spin polarized electron beam is determined to be 30.8 ±3.5% measured with a He optical polarimeter.
基金Project supported by the Chinese Academy of Sciences(Grant Nos.XDC07000000 and GJJSTD20200001)Hefei Comprehensive National Science CenterYouth Innovation Promotion Association of Chinese Academy of Sciences for the support。
文摘We report a new design of microwave source for X-band electron paramagnetic resonance spectrometer.The microwave source is equipped with a digital automatic frequency control circuit.The parameters of the digital automatic frequency control circuit can be flexibly configured for different experimental conditions,such as the input powers or the quality factors of the resonator.The configurability makes the microwave source universally compatible and greatly extends its application.To demonstrate the ability of adapting to various experimental conditions,the microwave source is tested by varying the input powers and the quality factors of the resonator.A satisfactory phase noise as low as-135 d Bc/Hz at 100-k Hz offset from the center frequency is achieved,due to the use of a phase-locked dielectric resonator oscillator and a direct digital synthesizer.Continuous-wave electron paramagnetic resonance experiments are conducted to examine the performance of the microwave source.The outstanding performance shows a prospect of wide applications of the microwave source in numerous fields of science.
文摘A new kind of electron source, the photoemissive monoenergetic electron source has been invented for calibrating the beta--magnetic spectrometer. It produceselectrons in the form of simulating a radioactive monoenergetic electron source andcan be made in any shape and size according tO the demands of experimentS. In thispaper, the principles and basic constructions of the photoemissive monoenergeticelectron source are described, the resultS of calibrating our 2’l’x bead--magneticspectrometer with a single strip arc shaped photoemissive monoenergetic electronsource are listed, a new way for determining resolution function of experimentslsystem in the research of neutrino rest mass has been posed and one of its actualapplications is also given.
基金supported by the Comprehensive Research Facility for Fusion Technology Program of China(No.2018-000052-73-01-001228)。
文摘Negative-ion-based neutral beam injection(NNBI)at high energy is still a potential heating and current drive method for future large-scale fusion reactors.One feature of the negative ion source is that the electrons are also accelerated with the negative ions in the accelerator.In addition to the electrons co-extracted from the source plasma,electrons are inevitably generated in the main acceleration stage due to the stripping loss of negative ions or the ionization of background gas.Many of these accelerated electrons can be ejected by the negative ion source,which poses a risk for the downstream components in the beamline of the NNBI system,especially the thermosensitive cryopumps.To prevent the ejected electrons from impacting the cryopumps,electron dumps have been designed for the beamline of the China Fusion Engineering Test Reactor(CFETR)advance neutral beam equipment(CANBE).Using a selfconsistent model of the negative ion accelerator,the generation and motion of the ejected electrons were simulated for different negative ion sources to be tested on the CANBE.Based on the orbits of the ejected electrons,a set of fixed and movable electron dumps was designed to be placed in front of the neutralizer inside the CANBE beamline.The effects of the electron dumps were quantitatively analyzed.
基金supported by InnoHK Project at Hong Kong Centre for Cerebro-cardiovascular Health Engineering (COCHE)City University of Hong Kong (7006108)。
文摘Aqueous Ni-Zn microbatteries are safe,reliable and inexpensive but notoriously suffer from inadequate energy and power densities.Herein,we present a novel mechanism of superoxide-activated Ni substrate that realizes the redox reaction featuring three-electron transfers(Ni↔Ni3+).The superoxide activates the direct redox reaction between Ni substrate and KNiO_(2)by lowering the reaction Gibbs free energy,supported by in-situ Raman and density functional theory simulations.The prepared chronopotentiostatic superoxidation-activated Ni(CPS-Ni)electrodes exhibit an ultrahigh capacity of 3.21 mAh cm^(-2)at the current density of 5 mA cm^(-2),nearly 8 times that of traditional one-electron processes electrodes.Even under the ultrahigh 200 mA cm^(-2)current density,the CPS-Ni electrodes show 86.4%capacity retention with a Columbic efficiency of 99.2%after 10,000 cycles.The CPS-Ni||Zn microbattery achieves an exceptional energy density of 6.88 mWh cm^(-2)and power density of 339.56 mW cm^(-2).Device demonstration shows that the power source can continuously operate for more than 7 days in powering the sensing and computation intensive practical application of photoplethysmographic waveform monitoring.This work paves the way to the development of multi-electron transfer mechanisms for advanced aqueous Ni-Zn batteries with high capacity and long lifetime.
文摘Quasistationary discharge mode setting in the explosive-emission sources is related to the saturation of the cathode plasma emissive ability resulting in the decrease of the velocity of plasma propagation into the interelectrode gap. It was shoran previously that the electron beam space charge providing the current rise slowing-down is of great importance in the process of the discharge mode stabilization. The paper considers a possibility of the discharge protraction at the expense of decrease of the ion charge order in the plasma composition and application of the directed plasma flows. The data concerning obtainig of micro- and millisecond electron beams in the explosive-emission sources are presented as well.
文摘Breakdown formation in the explosive-emission sources is related to the interelectrode gap filling with the cathode and anode plasma generated at the anode and in the gap under the beam influence. Under conditions of saturation of the cathode plasma emissive ability as well as when the measures on the emission boundary stabilization are taken, the anode plasma has the deciding part in the formation of the electron source breakdown. The paper presents the results of the anode plasma investigations obtained to solve the problem of the electron beam length increase in the explosive-emission sources. The data concerning the gas release from the anode, the mechanism of the anode plasma formation and the anode plasma influence on the parameters of the generated electron beam are presented as well.
文摘Formation of a quasi-stationary discharge or quasi-stationary emission mode in the explosive-emission electron sources is related to the current limitation resulting from the emissive ability saturation of cathode plasma with its expansion. The paper shows that in the process of the discharge current stabilization in the explosive-emission sources with the point- or blade-type emitters the essential role belongs to the electron beam space charge. Availability of the space charge results in limitation of the current growth velocity at the initial discharge phase and, hence, restricts the emissive ability of the cathode plasma and contributes to its saturation. In the vacuum diodes with multiemitter cathodes, the space charge availability increases the cathode operation stability and can provide obtaining of quasi-stationary beam current values or close to them resulting in formation of a plasma emission surface at the cathode close to the continuous one.
基金This work is supported by the National Natural Science Foundation of China under contract 50904038.
文摘Since loading complexand dynamic heat source is a difficult job during welding simulation process, methods are studied to add the load automatically. Firstly, an expert module for selecting welding heat source model is founded based on simulation knowledge and experienc Secondly, a method named as "High order routine" is presented, which creates subroutines of 3D dynamic heat source m'od, el for user. Then an automated tool is presented to load the welding heat source boundary based on Marc software. The tool uses Marc command file to robustly achieve the process. At last, an electron beam welding heat model is presented to express the "toading method.