The primary focus of this study was to investigate a series of novel motors and pumps,based on a new type of structure called double-stator.The double-stator structure can be used as pump or motor just based on the ap...The primary focus of this study was to investigate a series of novel motors and pumps,based on a new type of structure called double-stator.The double-stator structure can be used as pump or motor just based on the application requirements.A certain amount of pumps or motors can be formed in one shell,and these sub-pumps or sub-motors can work alone or be combined without influence on each other.So this kind of double-stator pump(motor) is called a multi-pump(multi-motor).Through the analysis of multifarious connection modes of the double-acting double-stator multi-pumps and multi-motors,the mathematical expressions of the output flow rate and the rotational speed are acquired.The results indicate that a quantity of different flow rates can be provided by one fixed-displacement multi-pump under the condition of unalterable driven speed by electromotor.Likewise,when supplied by settled input flow,without complex variable mechanism,the functions of double-speed,multiple-speed,and even differential connection can be obtained by employing the use of a double-stator multi-motor.The novel hydraulic transmission is made of such a double-stator multi-pump and multi-motor,and has broad application prospects.展开更多
A piezoelectric centrifugal pump was developed previously to overcome the low frequency responses of piezoelectric pumps with check valves and liquid reflux of conventional valveless piezoelectric pumps. However, the ...A piezoelectric centrifugal pump was developed previously to overcome the low frequency responses of piezoelectric pumps with check valves and liquid reflux of conventional valveless piezoelectric pumps. However, the electro-mechanical-fluidic analysis on this pump has not been done. Therefore, multi-field analysis and experimen- tal verification on piezoelectrically actuated centrifugal valveless pumps are conducted for liquid transport appli- cations. The valveless pump consists of two piezoelectric sheets and a metal tube with piezoelectric elements pushing the metal tube to swing at the first bending resonant fre- quency. The centrifugal force generated by the swinging motion will force the liquid out of the metal tube. The governing equations for the solid and fluid domains are established, and the coupling relations of the mechanical, electrical and fluid fields are described. The bending res- onant frequency and bending mode in solid domain are discussed, and the liquid flow rate, velocity profile, and gauge pressure are investigated in fluid domain. The working frequency and flow rate concerning different components sizes are analyzed and verified through experiments to guide the pump design. A fabricated pro- totype with an outer diameter of 2.2 mm and a length of 80 mm produced the largest flow rate of 13.8 mL/min at backpressure of 0.8 kPa with driving voltage of 80 Vpp. Bysolving the electro-mechanical-fluidic coupling problem, the model developed can provide theoretical guidance on the optimization of centrifugal valveless pump characters.展开更多
Computational fluid dynamics(CFD) can give a lot of potentially very useful information for hydraulic optimization design of pumps, however, it cannot directly state what kind of modification should be made to impro...Computational fluid dynamics(CFD) can give a lot of potentially very useful information for hydraulic optimization design of pumps, however, it cannot directly state what kind of modification should be made to improve such hydrodynamic performance. In this paper, a more convenient and effective approach is proposed by combined using of CFD, multi-objective genetic algorithm(MOGA) and artificial neural networks(ANN) for a double-channel pump's impeller, with maximum head and efficiency set as optimization objectives, four key geometrical parameters including inlet diameter, outlet diameter, exit width and midline wrap angle chosen as optimization parameters. Firstly, a multi-fidelity fitness assignment system in which fitness of impellers serving as training and comparison samples for ANN is evaluated by CFD, meanwhile fitness of impellers generated by MOGA is evaluated by ANN, is established and dramatically reduces the computational expense. Then, a modified MOGA optimization process, in which selection is performed independently in two sub-populations according to two optimization objectives, crossover and mutation is performed afterword in the merged population, is developed to ensure the global optimal solution to be found. Finally, Pareto optimal frontier is found after 500 steps of iterations, and two optimal design schemes are chosen according to the design requirements. The preliminary and optimal design schemes are compared, and the comparing results show that hydraulic performances of both pumps 1 and 2 are improved, with the head and efficiency of pump 1 increased by 5.7% and 5.2%, respectively in the design working conditions, meanwhile shaft power decreased in all working conditions, the head and efficiency of pump 2 increased by 11.7% and 5.9%, respectively while shaft power increased by 5.5%. Inner flow field analyses also show that the backflow phenomenon significantly diminishes at the entrance of the optimal impellers 1 and 2, both the area of vortex and intensity of vortex decreases in the whole flow channel. This paper provides a promising tool to solve the hydraulic optimization problem of pumps' impellers.展开更多
The Stokes spectrum in the stimulated Raman scattering (SRS) is very complicated. In this article, we use both Gaussian and Lorentz approximation to investigate the gain properties of multi pumping broadband Raman amp...The Stokes spectrum in the stimulated Raman scattering (SRS) is very complicated. In this article, we use both Gaussian and Lorentz approximation to investigate the gain properties of multi pumping broadband Raman amplifier, and present some schemes for flattening the gain. All the results show that the flatness of the gain spectrum is closely related to the pumping frequency grid. By researching the gain properties of Raman amplifiers of such ITU-T fibers as G.652, G.653, G.655 and large effective area non zero dispersion flattening fiber, we find that the Raman gain is associated with the fiber type and its transmission characteristics, especially it decreases with the increase of the effective core area.展开更多
Multi-wavelength continuous-wave self-Raman laser with an a-cut composite YVO4/Nd:YVO4/YVO4 crystal pumped by an 879-nm wavelength-locked laser diode is demonstrated for the first time.Multi-wavelength Raman lasers at...Multi-wavelength continuous-wave self-Raman laser with an a-cut composite YVO4/Nd:YVO4/YVO4 crystal pumped by an 879-nm wavelength-locked laser diode is demonstrated for the first time.Multi-wavelength Raman lasers at 1168.4,1176,1178.7,and 1201.6 nm are achieved by the first Stokes shift of the multi-wavelength fundamental lasers at 1064,1066.7,1073.6,1084,and 1085.6 nm with two Raman shifts of 890 and 816 cm^-1.A maximum Raman output power of 2.56 W is achieved through the use of a 20-mm-long composite crystal,with a corresponding optical conversion efficiency of 9.8%.The polarization directions of different fundamental and Raman lasers are investigated and found to be orthogonalπandσpolarizations.These orthogonally polarized multi-wavelength lasers with small wavelength separation pave the way to the development of a potential laser source for application in spectral analysis,laser radar and THz generation.展开更多
A novel flat-flat resonator consisting of two crystals(Nd:YAG + Nd:YVO4) is established for power scaling in a diode-end-pumped solid-state laser. We systematically compare laser characteristics between multi-seg...A novel flat-flat resonator consisting of two crystals(Nd:YAG + Nd:YVO4) is established for power scaling in a diode-end-pumped solid-state laser. We systematically compare laser characteristics between multi-segmented(Nd:YAG + Nd:YVO4) and conventional composite(Nd:YAG + Nd:YAG) crystals to demonstrate the feasibility of spectral line matching for output power scale-up in end-pumped lasers. A maximum continuous-wave output power of 79.2 W is reported at 1064 nm, with Mx2= 4.82, My2= 5.48, and a pumping power of 136 W in the multi-segmented crystals(Nd:YAG + Nd:YVO4). Compared to conventional composite crystals(Nd:YAG + Nd:YAG), the optical-optical conversion efficiency of multi-segmented crystals(Nd:YAG + Nd:YVO4) from 808 nm to 1064 nm is enhanced from 30% to 58.8%,while the laser output sensitivity as affected by the diode-laser temperature is reduced from 55% to 9%.展开更多
A multi functional wood dehumidification dryer has been developed recently. The dryer can carry out air dehumidification by using only one refrigeration system, in which heat supplying and moisture air are exhausted ...A multi functional wood dehumidification dryer has been developed recently. The dryer can carry out air dehumidification by using only one refrigeration system, in which heat supplying and moisture air are exhausted by changing the position of several air dampers. In this paper, the work principles and characteristics of the dehumidification dryer are introduced, and the testing results about the thermal engineering performance of the dehumidification dryer, as well as the experiment results of drying several species of lumbers are expounded.展开更多
An optimization model is established for a multi-product pipeline which has a known delivery demand and operation plan for each off-take station.The aim of this optimization model is to minimize the total pumping oper...An optimization model is established for a multi-product pipeline which has a known delivery demand and operation plan for each off-take station.The aim of this optimization model is to minimize the total pumping operation cost,considering not only factors including the energy equilibrium constraint,the maximum and minimum suction and discharge pressures constraints of pump stations,and pressure constraint at special elevation points,but also the regional differences in electricity prices along the pipeline.The dynamic programming method is applied to solve the model and to find the optimal pump configuration.展开更多
The experimental investigation of axial-flow pump has been rapidly developed to meet the needs of South-to-North Water Diversion Project of China. Owing to the boundary conditions of hub, blade tip clearance, much of ...The experimental investigation of axial-flow pump has been rapidly developed to meet the needs of South-to-North Water Diversion Project of China. Owing to the boundary conditions of hub, blade tip clearance, much of the physical phenomena and laws involved in this complex flow field can't be fully determined. The flow characteristics of the high efficiency axial-flow pump have been simulated by RNG k-e turbulence model and SIMPLEC arithmetic based on FLUENT software. Numerical results indicate that the data from the prediction show agreement with the experimental results, static pressure on pressure side of blades increases slightly at circumferential direction with radius increasing, and keep almost constant at the same radial while increasing gradually from inlet to exit on the suction side along flow direction at design conditions. The static pressure, total pressure and velocity at inlet, impeller outlet and vane outlet were measured by a five-hole probe, and a contrastive experiment was done to investigate the influence of hub leakage. The experimental results show that inlet flow is almost axial and the prerotation is very small at various conditions. The meridional velocity and circulation distribution are almost identical at impeller outlet at design conditions due to steady flow and high efficiency. The residual circulation exits at downstream of the guide vane, and the circumferential velocity component increases linearly from hub to tip at small flow rate conditions. Hub leakage in adjustable blades results in the decrease of the meridional velocity and circulation at blade exit near hub. The results of numerical simulation and experiments supply important flow structure information for the high-efficiency axial-flow pump.展开更多
In the adiabatic and weak-modulation quantum pump, net electron flow is driven from one reservoir to another by absorbing or emitting an energy quantum nω from or to the reservoirs. This paper considers high-order de...In the adiabatic and weak-modulation quantum pump, net electron flow is driven from one reservoir to another by absorbing or emitting an energy quantum nω from or to the reservoirs. This paper considers high-order dependence of the scattering matrix on the time. Non-sinusoidal behaviour of strong pumping is revealed. The relation between the pumped current and the ac driving amplitude varies from power of 2, 1 to 1/2 when stronger modulation is exerted. Open experimental observation can be interpreted by multi-energy-quantum-related processes.展开更多
基金Project(No.50975246)supported by the National Natural Science Foundation of China
文摘The primary focus of this study was to investigate a series of novel motors and pumps,based on a new type of structure called double-stator.The double-stator structure can be used as pump or motor just based on the application requirements.A certain amount of pumps or motors can be formed in one shell,and these sub-pumps or sub-motors can work alone or be combined without influence on each other.So this kind of double-stator pump(motor) is called a multi-pump(multi-motor).Through the analysis of multifarious connection modes of the double-acting double-stator multi-pumps and multi-motors,the mathematical expressions of the output flow rate and the rotational speed are acquired.The results indicate that a quantity of different flow rates can be provided by one fixed-displacement multi-pump under the condition of unalterable driven speed by electromotor.Likewise,when supplied by settled input flow,without complex variable mechanism,the functions of double-speed,multiple-speed,and even differential connection can be obtained by employing the use of a double-stator multi-motor.The novel hydraulic transmission is made of such a double-stator multi-pump and multi-motor,and has broad application prospects.
基金Supported by National Natural Science Foundation of China(Grant No.51305439)Jiangsu Provincial Natural Science Foundation of China(Grant No.BK20141205)
文摘A piezoelectric centrifugal pump was developed previously to overcome the low frequency responses of piezoelectric pumps with check valves and liquid reflux of conventional valveless piezoelectric pumps. However, the electro-mechanical-fluidic analysis on this pump has not been done. Therefore, multi-field analysis and experimen- tal verification on piezoelectrically actuated centrifugal valveless pumps are conducted for liquid transport appli- cations. The valveless pump consists of two piezoelectric sheets and a metal tube with piezoelectric elements pushing the metal tube to swing at the first bending resonant fre- quency. The centrifugal force generated by the swinging motion will force the liquid out of the metal tube. The governing equations for the solid and fluid domains are established, and the coupling relations of the mechanical, electrical and fluid fields are described. The bending res- onant frequency and bending mode in solid domain are discussed, and the liquid flow rate, velocity profile, and gauge pressure are investigated in fluid domain. The working frequency and flow rate concerning different components sizes are analyzed and verified through experiments to guide the pump design. A fabricated pro- totype with an outer diameter of 2.2 mm and a length of 80 mm produced the largest flow rate of 13.8 mL/min at backpressure of 0.8 kPa with driving voltage of 80 Vpp. Bysolving the electro-mechanical-fluidic coupling problem, the model developed can provide theoretical guidance on the optimization of centrifugal valveless pump characters.
基金Supported by National Natural Science Foundation of China(Grant No.51109094)Priority Academic Program Development of Jiangsu Higher Education Institutions of China
文摘Computational fluid dynamics(CFD) can give a lot of potentially very useful information for hydraulic optimization design of pumps, however, it cannot directly state what kind of modification should be made to improve such hydrodynamic performance. In this paper, a more convenient and effective approach is proposed by combined using of CFD, multi-objective genetic algorithm(MOGA) and artificial neural networks(ANN) for a double-channel pump's impeller, with maximum head and efficiency set as optimization objectives, four key geometrical parameters including inlet diameter, outlet diameter, exit width and midline wrap angle chosen as optimization parameters. Firstly, a multi-fidelity fitness assignment system in which fitness of impellers serving as training and comparison samples for ANN is evaluated by CFD, meanwhile fitness of impellers generated by MOGA is evaluated by ANN, is established and dramatically reduces the computational expense. Then, a modified MOGA optimization process, in which selection is performed independently in two sub-populations according to two optimization objectives, crossover and mutation is performed afterword in the merged population, is developed to ensure the global optimal solution to be found. Finally, Pareto optimal frontier is found after 500 steps of iterations, and two optimal design schemes are chosen according to the design requirements. The preliminary and optimal design schemes are compared, and the comparing results show that hydraulic performances of both pumps 1 and 2 are improved, with the head and efficiency of pump 1 increased by 5.7% and 5.2%, respectively in the design working conditions, meanwhile shaft power decreased in all working conditions, the head and efficiency of pump 2 increased by 11.7% and 5.9%, respectively while shaft power increased by 5.5%. Inner flow field analyses also show that the backflow phenomenon significantly diminishes at the entrance of the optimal impellers 1 and 2, both the area of vortex and intensity of vortex decreases in the whole flow channel. This paper provides a promising tool to solve the hydraulic optimization problem of pumps' impellers.
文摘The Stokes spectrum in the stimulated Raman scattering (SRS) is very complicated. In this article, we use both Gaussian and Lorentz approximation to investigate the gain properties of multi pumping broadband Raman amplifier, and present some schemes for flattening the gain. All the results show that the flatness of the gain spectrum is closely related to the pumping frequency grid. By researching the gain properties of Raman amplifiers of such ITU-T fibers as G.652, G.653, G.655 and large effective area non zero dispersion flattening fiber, we find that the Raman gain is associated with the fiber type and its transmission characteristics, especially it decreases with the increase of the effective core area.
基金Project supported by the National Natural Science Foundation of China(Grant No.11774301)the Young Scientists Fund of the National Natural Science Foundation of China(Grant No.11804292)
文摘Multi-wavelength continuous-wave self-Raman laser with an a-cut composite YVO4/Nd:YVO4/YVO4 crystal pumped by an 879-nm wavelength-locked laser diode is demonstrated for the first time.Multi-wavelength Raman lasers at 1168.4,1176,1178.7,and 1201.6 nm are achieved by the first Stokes shift of the multi-wavelength fundamental lasers at 1064,1066.7,1073.6,1084,and 1085.6 nm with two Raman shifts of 890 and 816 cm^-1.A maximum Raman output power of 2.56 W is achieved through the use of a 20-mm-long composite crystal,with a corresponding optical conversion efficiency of 9.8%.The polarization directions of different fundamental and Raman lasers are investigated and found to be orthogonalπandσpolarizations.These orthogonally polarized multi-wavelength lasers with small wavelength separation pave the way to the development of a potential laser source for application in spectral analysis,laser radar and THz generation.
基金Project supported by the National Defense Pre-Research Foundation of China(Grant No.9140A020105)
文摘A novel flat-flat resonator consisting of two crystals(Nd:YAG + Nd:YVO4) is established for power scaling in a diode-end-pumped solid-state laser. We systematically compare laser characteristics between multi-segmented(Nd:YAG + Nd:YVO4) and conventional composite(Nd:YAG + Nd:YAG) crystals to demonstrate the feasibility of spectral line matching for output power scale-up in end-pumped lasers. A maximum continuous-wave output power of 79.2 W is reported at 1064 nm, with Mx2= 4.82, My2= 5.48, and a pumping power of 136 W in the multi-segmented crystals(Nd:YAG + Nd:YVO4). Compared to conventional composite crystals(Nd:YAG + Nd:YAG), the optical-optical conversion efficiency of multi-segmented crystals(Nd:YAG + Nd:YVO4) from 808 nm to 1064 nm is enhanced from 30% to 58.8%,while the laser output sensitivity as affected by the diode-laser temperature is reduced from 55% to 9%.
文摘A multi functional wood dehumidification dryer has been developed recently. The dryer can carry out air dehumidification by using only one refrigeration system, in which heat supplying and moisture air are exhausted by changing the position of several air dampers. In this paper, the work principles and characteristics of the dehumidification dryer are introduced, and the testing results about the thermal engineering performance of the dehumidification dryer, as well as the experiment results of drying several species of lumbers are expounded.
文摘An optimization model is established for a multi-product pipeline which has a known delivery demand and operation plan for each off-take station.The aim of this optimization model is to minimize the total pumping operation cost,considering not only factors including the energy equilibrium constraint,the maximum and minimum suction and discharge pressures constraints of pump stations,and pressure constraint at special elevation points,but also the regional differences in electricity prices along the pipeline.The dynamic programming method is applied to solve the model and to find the optimal pump configuration.
基金supported by National Hi-tech Research and Development Program of China (863 Program, Grant No. 2007AA05Z207)National Science and Technology Support Scheme of China (Grant No. 2008BAF34B10)Jiangsu Provincial Graduate Student Innovation Foundation of China (Grant No. CX08B_064Z)
文摘The experimental investigation of axial-flow pump has been rapidly developed to meet the needs of South-to-North Water Diversion Project of China. Owing to the boundary conditions of hub, blade tip clearance, much of the physical phenomena and laws involved in this complex flow field can't be fully determined. The flow characteristics of the high efficiency axial-flow pump have been simulated by RNG k-e turbulence model and SIMPLEC arithmetic based on FLUENT software. Numerical results indicate that the data from the prediction show agreement with the experimental results, static pressure on pressure side of blades increases slightly at circumferential direction with radius increasing, and keep almost constant at the same radial while increasing gradually from inlet to exit on the suction side along flow direction at design conditions. The static pressure, total pressure and velocity at inlet, impeller outlet and vane outlet were measured by a five-hole probe, and a contrastive experiment was done to investigate the influence of hub leakage. The experimental results show that inlet flow is almost axial and the prerotation is very small at various conditions. The meridional velocity and circulation distribution are almost identical at impeller outlet at design conditions due to steady flow and high efficiency. The residual circulation exits at downstream of the guide vane, and the circumferential velocity component increases linearly from hub to tip at small flow rate conditions. Hub leakage in adjustable blades results in the decrease of the meridional velocity and circulation at blade exit near hub. The results of numerical simulation and experiments supply important flow structure information for the high-efficiency axial-flow pump.
基金Project supported by the National Natural Science Foundation of China(Grant No.11004063)the Fundamental Research Funds for the Central Universities(Grant No.2009ZM0299)+1 种基金the Natural Science Foundation of South China University of Technology (Grant No.x2lxE5090410)the Graduate Course Construction Project of South China University of Technology(Grant No.yjzk2009001)
文摘In the adiabatic and weak-modulation quantum pump, net electron flow is driven from one reservoir to another by absorbing or emitting an energy quantum nω from or to the reservoirs. This paper considers high-order dependence of the scattering matrix on the time. Non-sinusoidal behaviour of strong pumping is revealed. The relation between the pumped current and the ac driving amplitude varies from power of 2, 1 to 1/2 when stronger modulation is exerted. Open experimental observation can be interpreted by multi-energy-quantum-related processes.