期刊文献+
共找到212,428篇文章
< 1 2 250 >
每页显示 20 50 100
Robust and Biodegradable Heterogeneous Electronics with Customizable Cylindrical Architecture for Interference-Free Respiratory Rate Monitoring
1
作者 Jing Zhang Wenqi Wang +9 位作者 Sanwei Hao Hongnan Zhu Chao Wang Zhouyang Hu Yaru Yu Fangqing Wang Peng Fu Changyou Shao Jun Yang Hailin Cong 《Nano-Micro Letters》 2026年第1期914-934,共21页
A rapidly growing field is piezoresistive sensor for accurate respiration rate monitoring to suppress the worldwide respiratory illness.However,a large neglected issue is the sensing durability and accuracy without in... A rapidly growing field is piezoresistive sensor for accurate respiration rate monitoring to suppress the worldwide respiratory illness.However,a large neglected issue is the sensing durability and accuracy without interference since the expiratory pressure always coupled with external humidity and temperature variations,as well as mechanical motion artifacts.Herein,a robust and biodegradable piezoresistive sensor is reported that consists of heterogeneous MXene/cellulose-gelation sensing layer and Ag-based interdigital electrode,featuring customizable cylindrical interface arrangement and compact hierarchical laminated architecture for collectively regulating the piezoresistive response and mechanical robustness,thereby realizing the long-term breath-induced pressure detection.Notably,molecular dynamics simulations reveal the frequent angle inversion and reorientation of MXene/cellulose in vacuum filtration,driven by shear forces and interfacial interactions,which facilitate the establishment of hydrogen bonds and optimize the architecture design in sensing layer.The resultant sensor delivers unprecedented collection features of superior stability for off-axis deformation(0-120°,~2.8×10^(-3) A)and sensing accuracy without crosstalk(humidity 50%-100%and temperature 30-80).Besides,the sensor-embedded mask together with machine learning models is achieved to train and classify the respiration status for volunteers with different ages(average prediction accuracy~90%).It is envisioned that the customizable architecture design and sensor paradigm will shed light on the advanced stability of sustainable electronics and pave the way for the commercial application in respiratory monitory. 展开更多
关键词 Wearable electronics Piezoresistive sensor HETEROGENEOUS CELLULOSE Respiratory monitoring
在线阅读 下载PDF
Intelligent Semantic Segmentation with Vision Transformers for Aerial Vehicle Monitoring
2
作者 Moneerah Alotaibi 《Computers, Materials & Continua》 2026年第1期1629-1648,共20页
Advanced traffic monitoring systems encounter substantial challenges in vehicle detection and classification due to the limitations of conventional methods,which often demand extensive computational resources and stru... Advanced traffic monitoring systems encounter substantial challenges in vehicle detection and classification due to the limitations of conventional methods,which often demand extensive computational resources and struggle with diverse data acquisition techniques.This research presents a novel approach for vehicle classification and recognition in aerial image sequences,integrating multiple advanced techniques to enhance detection accuracy.The proposed model begins with preprocessing using Multiscale Retinex(MSR)to enhance image quality,followed by Expectation-Maximization(EM)Segmentation for precise foreground object identification.Vehicle detection is performed using the state-of-the-art YOLOv10 framework,while feature extraction incorporates Maximally Stable Extremal Regions(MSER),Dense Scale-Invariant Feature Transform(Dense SIFT),and Zernike Moments Features to capture distinct object characteristics.Feature optimization is further refined through a Hybrid Swarm-based Optimization algorithm,ensuring optimal feature selection for improved classification performance.The final classification is conducted using a Vision Transformer,leveraging its robust learning capabilities for enhanced accuracy.Experimental evaluations on benchmark datasets,including UAVDT and the Unmanned Aerial Vehicle Intruder Dataset(UAVID),demonstrate the superiority of the proposed approach,achieving an accuracy of 94.40%on UAVDT and 93.57%on UAVID.The results highlight the efficacy of the model in significantly enhancing vehicle detection and classification in aerial imagery,outperforming existing methodologies and offering a statistically validated improvement for intelligent traffic monitoring systems compared to existing approaches. 展开更多
关键词 Machine learning semantic segmentation remote sensors deep learning object monitoring system
在线阅读 下载PDF
Noninvasive On-Skin Biosensors for Monitoring Diabetes Mellitus
3
作者 Ali Sedighi Tianyu Kou +1 位作者 Hui Huang Yi Li 《Nano-Micro Letters》 2026年第1期375-437,共63页
Diabetes mellitus represents a major global health issue,driving the need for noninvasive alternatives to traditional blood glucose monitoring methods.Recent advancements in wearable technology have introduced skin-in... Diabetes mellitus represents a major global health issue,driving the need for noninvasive alternatives to traditional blood glucose monitoring methods.Recent advancements in wearable technology have introduced skin-interfaced biosensors capable of analyzing sweat and skin biomarkers,providing innovative solutions for diabetes diagnosis and monitoring.This review comprehensively discusses the current developments in noninvasive wearable biosensors,emphasizing simultaneous detection of biochemical biomarkers(such as glucose,cortisol,lactate,branched-chain amino acids,and cytokines)and physiological signals(including heart rate,blood pressure,and sweat rate)for accurate,personalized diabetes management.We explore innovations in multimodal sensor design,materials science,biorecognition elements,and integration techniques,highlighting the importance of advanced data analytics,artificial intelligence-driven predictive algorithms,and closed-loop therapeutic systems.Additionally,the review addresses ongoing challenges in biomarker validation,sensor stability,user compliance,data privacy,and regulatory considerations.A holistic,multimodal approach enabled by these next-generation wearable biosensors holds significant potential for improving patient outcomes and facilitating proactive healthcare interventions in diabetes management. 展开更多
关键词 Wearable biosensors Multimodal sensors Diabetes monitoring Sweat biomarkers Glucose biosensors
在线阅读 下载PDF
Skin-Inspired Ultra-Linear Flexible Iontronic Pressure Sensors for Wearable Musculoskeletal Monitoring
4
作者 Pei Li Shipan Lang +6 位作者 Lei Xie Yong Zhang Xin Gou Chao Zhang Chenhui Dong Chunbao Li Jun Yang 《Nano-Micro Letters》 2026年第2期454-470,共17页
The growing prevalence of exercise-induced tibial stress fractures demands wearable sensors capable of monitoring dynamic musculoskeletal loads with medical-grade precision.While flexible pressure-sensing insoles show... The growing prevalence of exercise-induced tibial stress fractures demands wearable sensors capable of monitoring dynamic musculoskeletal loads with medical-grade precision.While flexible pressure-sensing insoles show clinical potential,their development has been hindered by the intrinsic trade-off between high sensitivity and full-range linearity(R^(2)>0.99 up to 1 MPa)in conventional designs.Inspired by the tactile sensing mechanism of human skin,where dermal stratification enables wide-range pressure adaptation and ion-channelregulated signaling maintains linear electrical responses,we developed a dual-mechanism flexible iontronic pressure sensor(FIPS).This innovative design synergistically combines two bioinspired components:interdigitated fabric microstructures enabling pressure-proportional contact area expansion(αP1/3)and iontronic film facilitating self-adaptive ion concentration modulation(αP^(2/3)),which together generate a linear capacitance-pressure response(CαP).The FIPS achieves breakthrough performance:242 kPa^(-1)sensitivity with 0.997linearity across 0-1 MPa,yielding a record linear sensing factor(LSF=242,000).The design is validated across various substrates and ionic materials,demonstrating its versatility.Finally,the FIPS-driven design enables a smart insole demonstrating 1.8%error in tibial load assessment during gait analysis,outperforming nonlinear counterparts(6.5%error)in early fracture-risk prediction.The biomimetic design framework establishes a universal approach for developing high-performance linear sensors,establishing generalized principles for medical-grade wearable devices. 展开更多
关键词 Iontronic sensor Skin-inspired design Linear range Linear sensing factor Biomechanical monitoring
在线阅读 下载PDF
基于网络药理学、分子对接与PRM靶向蛋白验证探讨苁蓉舒痉颗粒治疗帕金森病的作用机制 被引量:4
5
作者 刘海鑫 倪慧心 +6 位作者 周美 范自立 高正涛 吴方真 林瑶 许茜 蔡晶 《中国药理学通报》 北大核心 2025年第2期365-372,共8页
目的结合网络药理学、分子对接与PRM蛋白相对定量分析探索苁蓉舒痉颗粒(Congrong Shujing granules,CSGs)治疗帕金森病(Parkinson’s disease,PD)的作用机制。方法通过数据库获取CSGs的有效成分和PD的靶点。取药物与疾病的交集靶点,进... 目的结合网络药理学、分子对接与PRM蛋白相对定量分析探索苁蓉舒痉颗粒(Congrong Shujing granules,CSGs)治疗帕金森病(Parkinson’s disease,PD)的作用机制。方法通过数据库获取CSGs的有效成分和PD的靶点。取药物与疾病的交集靶点,进行“药物-活性成分-靶点”网络和蛋白互作网络的构建与分析,将交集靶点基因导入David数据库进行GO和KEGG富集分析,并将主要成分与关键靶点进行分子对接。将27只SD大鼠随机分为正常组9只、模型组9只和治疗组9只,于疗程d 1、7、14采用PRM蛋白相对定量分析法检测大鼠黑质纹状体关键靶蛋白特异性肽段表达量的变化情况。结果CSGs主要成分为丹参醛、黄芩素、槲皮素和山柰酚等;治疗PD最为关键的靶点为TP53、AKT1、EGFR、HSP90AA1和STAT3;KEGG分析主要富集:MAPK、PI3K-Akt和神经营养因子等信号通路。核心成分与核心靶点的分子对接表明,药物与靶点的结合具有较好活性。PRM分析发现ASK1、JNK1,JNK3目标肽段表达量各组间存在差异(P<0.05)。结论CSGs可通过ASK1-JNK信号通路,缓解内质网应激,抑制细胞凋亡,发挥神经保护作用。 展开更多
关键词 帕金森病 苁蓉舒痉颗粒 网络药理学 分子对接 prm ASK1-JNK信号通路
暂未订购
基于PRM的颗粒破碎数值模拟方法研究进展
6
作者 孙义豪 刘金艳 +2 位作者 左蔚然 黄岚 周子浩 《金属矿山》 北大核心 2025年第9期98-106,共9页
颗粒破碎是矿业、化工、建材等领域的关键环节,其能量耗散与破碎行为关乎工程设计和设备性能优化。传统实验方法在捕捉动态破碎过程与微观机制方面存在局限,且成本较高。基于颗粒替换法(particle replacement method,PRM)的数值模拟方... 颗粒破碎是矿业、化工、建材等领域的关键环节,其能量耗散与破碎行为关乎工程设计和设备性能优化。传统实验方法在捕捉动态破碎过程与微观机制方面存在局限,且成本较高。基于颗粒替换法(particle replacement method,PRM)的数值模拟方法为研究颗粒破碎提供了有效手段。该方法通过预设颗粒替代模式和破碎准则来模拟颗粒的破碎过程。通过文献调研与对比分析,系统综述了基于接触力、应力张量和能量的三类破碎准则的适用性与局限性,并探讨了子代数量确定、质量守恒实现及非球形建模等替换模式的关键问题。结果表明,PRM在预测破碎后颗粒分布与形态方面具有较好潜力,但仍存在准则缺乏统一性、替换模式依赖经验等问题。未来应致力于构建普适性破碎准则、发展多物理场耦合模型,并结合机器学习与实验数据提升模拟精度与工程适用性。 展开更多
关键词 颗粒破碎 数值模拟 prm 破碎准则 替换模式
在线阅读 下载PDF
日本脑炎病毒prM蛋白单克隆抗体的制备及其B细胞表位的鉴定
7
作者 杨笑笑 杨兴淼 +1 位作者 刘亚林 曹瑞兵 《南京农业大学学报》 北大核心 2025年第3期591-603,共13页
[目的]本文旨在制备日本脑炎病毒(JEV)prM蛋白的单克隆抗体,为进一步了解prM的结构和功能、建立特异性检测方法以及研究JEV prM蛋白功能奠定基础。[方法]将prm基因克隆至原核表达载体pET-32a,诱导表达并纯化prM蛋白,随后将其免疫小鼠,... [目的]本文旨在制备日本脑炎病毒(JEV)prM蛋白的单克隆抗体,为进一步了解prM的结构和功能、建立特异性检测方法以及研究JEV prM蛋白功能奠定基础。[方法]将prm基因克隆至原核表达载体pET-32a,诱导表达并纯化prM蛋白,随后将其免疫小鼠,通过细胞融合和亚克隆得到分泌抗prM单克隆抗体的杂交瘤细胞株,制备腹水并进行效价测定,通过Western blot和IFA验证其特异性,并进行空斑中和试验测定其中和活性,利用原核表达多段截短体蛋白确定单克隆抗体抗原表位并进行保守性分析,将其初步应用于感染检测及亚细胞定位分析。[结果]经细胞融合和3次亚克隆后成功获得1株能稳定分泌抗prM单克隆抗体(mAb)的细胞株,命名为4H6,所制备的腹水效价可达到1∶1 638 400,经鉴定,该prM mAb重链属于IgG2b,轻链为κ型。Western blot以及IFA试验均证明该抗体具有良好的特异性。空斑减少中和试验显示prM 4H6分泌的mAb不具备中和活性。通过表达截短蛋白鉴定出prM 4H6分泌的mAb所识别的抗原表位位于^(30)GENRCWVRAIDVGYMC^(45),结合生物信息学分析发现,该表位位于prM蛋白表面且在JEV不同毒株之间高度保守。成功将prM 4H6分泌mAb初步应用于JEV感染检测及prM蛋白的亚细胞定位分析。[结论]成功制备1株高效分泌抗JEV prM蛋白单克隆抗体细胞株,其分泌的特异性mAb的B细胞表位识别区位于pr表面,为分析prM蛋白在病毒复制过程中的生物学功能以及与其他病毒蛋白(如E蛋白或宿主分子)之间的相互作用提供有效工具。 展开更多
关键词 日本脑炎病毒 prm蛋白 原核表达 单克隆抗体 B细胞表位
在线阅读 下载PDF
基于改进PRM算法和事件触发机制的无人船动态避碰轨迹规划
8
作者 王子铭 陈顺怀 郑龙 《船舶力学》 北大核心 2025年第8期1239-1249,共11页
无人船的轨迹规划是无人船自主航行的重要环节。本文基于改进PRM算法和事件触发机制提出一种无人船动态避碰的轨迹规划方法。首先,将PRM和A^(*)结合得到PRM-A^(*)算法,并基于PRM-A^(*)算法建立无人船轨迹规划模型。根据当前时刻的环境... 无人船的轨迹规划是无人船自主航行的重要环节。本文基于改进PRM算法和事件触发机制提出一种无人船动态避碰的轨迹规划方法。首先,将PRM和A^(*)结合得到PRM-A^(*)算法,并基于PRM-A^(*)算法建立无人船轨迹规划模型。根据当前时刻的环境态势建立栅格地图,通过PRM-A^(*)算法规划无人船的避碰路径,并建立该避碰路径的S-T栅格图。通过PRM-A^(*)算法对S-T栅格图规划无人船航速,从而得到当前时刻的无人船避碰轨迹。其次,基于事件触发机制建立无人船的动态避碰模型。根据无人船的TCPA和DCPA建立无人船碰撞危险度评估模型,并以此为基础设置事件触发条件;事件触发后,根据当前时间窗的环境态势规划无人船避碰轨迹。最后,分别进行开阔水域和限制水域的无人船轨迹规划仿真试验。结果显示,本算法可使无人船能有效地避开局部水域中静态障碍物和移动障碍物,并节省计算资源,提升计算性能。 展开更多
关键词 无人船 轨迹规划 prm-A^(*)算法 事件触发机制 TCPA DCPA
在线阅读 下载PDF
Assessing the corrosion protection property of coatings loaded with corrosion inhibitors using the real-time atmospheric corrosion monitoring technique 被引量:1
9
作者 Xiaoxue Wang Lulu Jin +8 位作者 Jinke Wang Rongqiao Wang Xiuchun Liu Kai Gao Jingli Sun Yong Yuan Lingwei Ma Hongchang Qian Dawei Zhang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS 2025年第1期119-126,共8页
The atmospheric corrosion monitoring(ACM)technique has been widely employed to track the real-time corrosion behavior of metal materials.However,limited studies have applied ACM to the corrosion protection properties ... The atmospheric corrosion monitoring(ACM)technique has been widely employed to track the real-time corrosion behavior of metal materials.However,limited studies have applied ACM to the corrosion protection properties of organic coatings.This study compared a bare epoxy coating with one containing zinc phosphate corrosion inhibitors,both applied on ACM sensors,to observe their corrosion protection properties over time.Coatings with artificial damage via scratches were exposed to immersion and alternating dry and wet environments,which allowed for monitoring galvanic corrosion currents in real-time.Throughout the corrosion tests,the ACM currents of the zinc phosphate/epoxy coating were considerably lower than those of the blank epoxy coating.The trend in ACM current variations closely matched the results obtained from regular electrochemical tests and surface analysis.This alignment highlights the potential of the ACM technique in evaluating the corrosion protection capabilities of organic coatings.Compared with the blank epoxy coating,the zinc phosphate/epoxy coating showed much-decreased ACM current values that confirmed the effective inhibition of zinc phosphate against steel corrosion beneath the damaged coating. 展开更多
关键词 atmospheric corrosion monitoring technology corrosion inhibitor COATING carbon steel corrosion protection
在线阅读 下载PDF
一种改进的场景自适应PRM路径规划算法
10
作者 杨景照 王超 张煜 《指挥控制与仿真》 2025年第3期34-39,共6页
针对动态复杂环境下的地面无人装备路径规划时存在的精细度、动态性与规划实时性之间的矛盾,提出一种基于风险融合代价地图和自适应PRM的地面无人装备路径规划算法。首先,基于多要素环境场景建立风险融合代价地图,通过高斯卷积自适应采... 针对动态复杂环境下的地面无人装备路径规划时存在的精细度、动态性与规划实时性之间的矛盾,提出一种基于风险融合代价地图和自适应PRM的地面无人装备路径规划算法。首先,基于多要素环境场景建立风险融合代价地图,通过高斯卷积自适应采样、非线性概率提升和二次采样策略等机制构建场景自适应PRM概率路图,并利用局部规划器对概率路图权值的动态更新,从而实现全局低风险代价路径的优化搜索。仿真结果表明,该方法能较好实现动态复杂环境下的精细度、动态性与规划实时性的平衡。 展开更多
关键词 prm 自适应采样 高斯卷积
在线阅读 下载PDF
Atmospheric scattering model and dark channel prior constraint network for environmental monitoring under hazy conditions 被引量:2
11
作者 Lintao Han Hengyi Lv +3 位作者 Chengshan Han Yuchen Zhao Qing Han Hailong Liu 《Journal of Environmental Sciences》 2025年第6期203-218,共16页
Environmentalmonitoring systems based on remote sensing technology have a wider monitoringrange and longer timeliness, which makes them widely used in the detection andmanagement of pollution sources. However, haze we... Environmentalmonitoring systems based on remote sensing technology have a wider monitoringrange and longer timeliness, which makes them widely used in the detection andmanagement of pollution sources. However, haze weather conditions degrade image qualityand reduce the precision of environmental monitoring systems. To address this problem,this research proposes a remote sensing image dehazingmethod based on the atmosphericscattering model and a dark channel prior constrained network. The method consists ofa dehazing network, a dark channel information injection network (DCIIN), and a transmissionmap network. Within the dehazing network, the branch fusion module optimizesfeature weights to enhance the dehazing effect. By leveraging dark channel information,the DCIIN enables high-quality estimation of the atmospheric veil. To ensure the outputof the deep learning model aligns with physical laws, we reconstruct the haze image usingthe prediction results from the three networks. Subsequently, we apply the traditionalloss function and dark channel loss function between the reconstructed haze image and theoriginal haze image. This approach enhances interpretability and reliabilitywhile maintainingadherence to physical principles. Furthermore, the network is trained on a synthesizednon-homogeneous haze remote sensing dataset using dark channel information from cloudmaps. The experimental results show that the proposed network can achieve better imagedehazing on both synthetic and real remote sensing images with non-homogeneous hazedistribution. This research provides a new idea for solving the problem of decreased accuracyof environmental monitoring systems under haze weather conditions and has strongpracticability. 展开更多
关键词 Remote sensing Image dehazing Environmental monitoring Neural network INTERPRETABILITY
原文传递
Artificial Intelligence-Assisted Conductive Hydrogel Dressings for Refractory Wounds Monitoring 被引量:2
12
作者 Yumo She He Liu +10 位作者 Hailiang Yuan Yiqi Li Xunjie Liu Ruonan Liu Mengyao Wang Tingting Wang Lina Wang Meihan Liu Wenyu Wan Ye Tian Kai Zhang 《Nano-Micro Letters》 2025年第12期492-525,共34页
Refractory wounds cause significant harm to the health of patients and the most common treatments in clinical practice are surgical debridement and wound dressings.However,certain challenges,including surgical difficu... Refractory wounds cause significant harm to the health of patients and the most common treatments in clinical practice are surgical debridement and wound dressings.However,certain challenges,including surgical difficulty,lengthy recovery times,and a high recurrence rate persist.Conductive hydrogel dressings with combined monitoring and therapeutic properties have strong advantages in promoting wound healing due to the stimulation of endogenous current on wounds and are the focus of recent advancements.Therefore,this review introduces the mechanism of conductive hydrogel used for wound monitoring and healing,the materials selection of conductive hydrogel dressings used for wound monitoring,focuses on the conductive hydrogel sensor to monitor the output categories of wound status signals,proving invaluable for non-invasive,real-time evaluation of wound condition to encourage wound healing.Notably,the research of artificial intelligence(AI)model based on sensor derived data to predict the wound healing state,AI makes use of this abundant data set to forecast and optimize the trajectory of tissue regeneration and assess the stage of wound healing.Finally,refractory wounds including pressure ulcers,diabetes ulcers and articular wounds,and the corresponding wound monitoring and healing process are discussed in detail.This manuscript supports the growth of clinically linked disciplines and offers motivation to researchers working in the multidisciplinary field of conductive hydrogel dressings. 展开更多
关键词 Artificial intelligence Conductive hydrogels Refractory wounds Wound healing Wound monitoring
暂未订购
Accurate Machine Learning‑based Monitoring of Anesthesia Depth with EEG Recording 被引量:1
13
作者 Zhiyi Tu Yuehan Zhang +9 位作者 Xueyang Lv Yanyan Wang Tingting Zhang Juan Wang Xinren Yu Pei Chen Suocheng Pang Shengtian Li Xiongjie Yu Xuan Zhao 《Neuroscience Bulletin》 2025年第3期449-460,共12页
General anesthesia,pivotal for surgical procedures,requires precise depth monitoring to mitigate risks ranging from intraoperative awareness to postoperative cognitive impairments.Traditional assessment methods,relyin... General anesthesia,pivotal for surgical procedures,requires precise depth monitoring to mitigate risks ranging from intraoperative awareness to postoperative cognitive impairments.Traditional assessment methods,relying on physiological indicators or behavioral responses,fall short of accurately capturing the nuanced states of unconsciousness.This study introduces a machine learning-based approach to decode anesthesia depth,leveraging EEG data across different anesthesia states induced by propofol and esketamine in rats.Our findings demonstrate the model’s robust predictive accuracy,underscored by a novel intrasubject dataset partitioning and a 5-fold cross-validation method.The research diverges from conventional monitoring by utilizing anesthetic infusion rates as objective indicators of anesthesia states,highlighting distinct EEG patterns and enhancing prediction accuracy.Moreover,the model’s ability to generalize across individuals suggests its potential for broad clinical application,distinguishing between anesthetic agents and their depths.Despite relying on rat EEG data,which poses questions about real-world applicability,our approach marks a significant advance in anesthesia monitoring. 展开更多
关键词 ELECTROENCEPHALOGRAM PROPOFOL KETAMINE Machine learning Anesthesia monitoring
原文传递
A Fully‑Printed Wearable Bandage‑Based Electrochemical Sensor with pH Correction for Wound Infection Monitoring
14
作者 Kanyawee Kaewpradub Kornautchaya Veenuttranon +2 位作者 Husanai Jantapaso Pimonsri Mittraparp‑arthorn Itthipon Jeerapan 《Nano-Micro Letters》 SCIE EI CAS 2025年第3期355-375,共21页
Wearable sensing systems have been designed to monitor health conditions in real-time by detecting analytes in human biofluids.Wound diagnosis remains challenging,necessitating suitable materials for high-performance ... Wearable sensing systems have been designed to monitor health conditions in real-time by detecting analytes in human biofluids.Wound diagnosis remains challenging,necessitating suitable materials for high-performance wearable sensors to offer prompt feedback.Existing devices have limitations in measuring pH and the concentration of pH-dependent electroactive species simultaneously,which is crucial for obtaining a comprehensive understanding of wound status and optimizing biosensors.Therefore,improving materials and analysis system accuracy is essential.This article introduces the first example of a flexible array capable of detecting pyocyanin,a bacterial virulence factor,while correcting dynamic pH fluctuations.We demonstrate that this combined sensor enhances accuracy by mitigating the impact of pH variability on pyocyanin sensor response.Customized screen-printable inks were developed to enhance analytical performance.The analytical performances of two sensitive sensor systems(i.e.,fully-printed porous graphene/multiwalled carbon nanotube(CNT)and polyaniline/CNT composites for pyocyanin and pH sensors)are evaluated.Partial least square regression is employed to analyze nonzero-order data arrays from square wave voltammetric and potentiometric measurements of pyocyanin and pH sensors to establish a predictive model for pyocyanin concentration in complex fluids.This sensitive and effective strategy shows potential for personalized applications due to its affordability,ease of use,and ability to adjust for dynamic pH changes. 展开更多
关键词 PYOCYANIN BANDAGES Wound monitoring Biosensor Wearable device
在线阅读 下载PDF
Plateau frequency exploration of longitudinal guided waves for stress monitoring of steel strand 被引量:1
15
作者 ZHANG Jing LI Xuejian +2 位作者 LI Gang YUAN Ye YANG Dong 《Journal of Southeast University(English Edition)》 2025年第1期44-50,共7页
To tackle the issue of notch frequency and center frequency drift of the L(0,1)mode guided wave in ultra⁃sonic guided wave⁃based stress monitoring of prestressed steel strands,a method using higher⁃order mode plateau ... To tackle the issue of notch frequency and center frequency drift of the L(0,1)mode guided wave in ultra⁃sonic guided wave⁃based stress monitoring of prestressed steel strands,a method using higher⁃order mode plateau fre⁃quencies is adopted.First,the correlation between group velocity peaks and phase velocities at these plateau frequen⁃cies is analyzed.This analysis establishes a quantitative rela⁃tionship between phase velocity and stress in the steel strand,providing a theoretical foundation for stress monitor⁃ing.Then the two⁃dimensional Fourier transform is em⁃ployed to separate wave modes.Dynamic programming techniques are applied in the frequency⁃velocity domain to extract higher⁃order modes.By identifying the group veloc⁃ity peaks of these separated higher⁃order modes,the plateau frequencies of guided waves are determined,enabling indi⁃rect measurement of stress in the steel strand.To validate this method,finite element simulations are conducted under three scenarios.Results show that the higher⁃order modes of transient signals from three different positions can be ac⁃curately extracted,leading to successful cable stress moni⁃toring.This approach effectively circumvents the issue of guided wave frequency drift and improves stress monitoring accuracy.Consequently,it significantly improves the appli⁃cation of ultrasonic guided wave technology in structural health monitoring. 展开更多
关键词 steel strand ultrasonic guided wave plateau frequency mode separation stress monitoring
在线阅读 下载PDF
Role of disturbance coefficient in monitoring and treatment of cerebral edema in patients with cerebral hemorrhage 被引量:1
16
作者 Wen-Wen Gao Xiao-Bing Jiang +9 位作者 Peng Chen Liang Zhang Lei Yang Zhi-Hai Yuan Yao Wei Xiao-Qiang Li Xiao-Lu Tang Feng-Lu Wang Hao Wu Hai-Kang Zhao 《World Journal of Clinical Cases》 2025年第14期16-24,共9页
BACKGROUND At present,the conventional methods for diagnosing cerebral edema in clinical practice are computed tomography(CT)and magnetic resonance imaging(MRI),which can evaluate the location and degree of peripheral... BACKGROUND At present,the conventional methods for diagnosing cerebral edema in clinical practice are computed tomography(CT)and magnetic resonance imaging(MRI),which can evaluate the location and degree of peripheral cerebral edema,but cannot realize quantification.When patients have symptoms of diffuse cerebral edema or high cranial pressure,CT or MRI often suggests that cerebral edema is lagging and cannot be dynamically monitored in real time.Intracranial pressure monitoring is the gold standard,but it is an invasive operation with high cost and complications.For clinical purposes,the ideal cerebral edema monitoring should be non-invasive,real-time,bedside,and continuous dynamic monitoring.The dis-turbance coefficient(DC)was used in this study to dynamically monitor the occu-rrence,development,and evolution of cerebral edema in patients with cerebral hemorrhage in real time,and review head CT or MRI to evaluate the development of the disease and guide further treatment,so as to improve the prognosis of patients with cerebral hemorrhage.AIM To offer a promising new approach for non-invasive adjuvant therapy in cerebral edema treatment.METHODS A total of 160 patients with hypertensive cerebral hemorrhage admitted to the Department of Neurosurgery,Second Affiliated Hospital of Xi’an Medical University from September 2018 to September 2019 were recruited.The patients were randomly divided into a control group(n=80)and an experimental group(n=80).Patients in the control group received conventional empirical treatment,while those in the experimental group were treated with mannitol dehydration under the guidance of DC.Subsequently,we compared the two groups with regards to the total dosage of mannitol,the total course of treatment,the incidence of complications,and prognosis.RESULTS The mean daily consumption of mannitol,the total course of treatment,and the mean hospitalization days were 362.7±117.7 mL,14.8±5.2 days,and 29.4±7.9 in the control group and 283.1±93.6 mL,11.8±4.2 days,and 23.9±8.3 in the experimental group(P<0.05).In the control group,there were 20 patients with pulmonary infection(25%),30 with electrolyte disturbance(37.5%),20 with renal impairment(25%),and 16 with stress ulcer(20%).In the experimental group,pulmonary infection occurred in 18 patients(22.5%),electrolyte disturbance in 6(7.5%),renal impairment in 2(2.5%),and stress ulcers in 15(18.8%)(P<0.05).According to the Glasgow coma scale score 6 months after discharge,the prognosis of the control group was good in 20 patients(25%),fair in 26(32.5%),and poor in 34(42.5%);the prognosis of the experimental group was good in 32(40%),fair in 36(45%),and poor in 12(15%)(P<0.05).CONCLUSION Using DC for non-invasive dynamic monitoring of cerebral edema demonstrates considerable clinical potential.It reduces mannitol dosage,treatment duration,complication rates,and hospital stays,ultimately lowering hospital-ization costs.Additionally,it improves overall patient prognosis,offering a promising new approach for non-invasive adjuvant therapy in cerebral edema treatment. 展开更多
关键词 Noninvasive cerebral edema monitor Disturbance coefficient HYPERTENSION Cerebral hemorrhage Cerebral edema MANNITOL
暂未订购
Designing and optimizing an intelligent self-powered condition monitoring system for mining belt conveyor idlers and its application 被引量:1
17
作者 Xuanbo JIAO Zhixia WANG +2 位作者 Wei WANG F.S.GU S.HEYNS 《Applied Mathematics and Mechanics(English Edition)》 2025年第9期1679-1698,共20页
Belt conveyors are extensively utilized in mining and power industries.In a typical coal mine conveyor system,coal is transported over distances exceeding 2 km,involving more than 20000 idlers,which far exceeds a reas... Belt conveyors are extensively utilized in mining and power industries.In a typical coal mine conveyor system,coal is transported over distances exceeding 2 km,involving more than 20000 idlers,which far exceeds a reasonable manual inspection capacity.Given that idlers typically have a lifespan of 1-2 years,there is an urgent need for a rapid,cost-effective,and intelligent safety monitoring system.However,current embedded systems face prohibitive replacement costs,while conventional monitoring technologies suffer from inefficiency at low rotational speeds and lack systematic structural optimization frameworks for diverse idler types and parameters.To address these challenges,this paper introduces an integrated,on-site detachable self-powered idler condition monitoring system(ICMS).This system combines energy harvesting based on the magnetic modulation technology with wireless condition monitoring capabilities.Specifically,it develops a data-driven model integrating convolutional neural networks(CNNs) with genetic algorithms(GAs).The conventional testing results show that the data-driven model not only significantly accelerates the parameter response time,but also achieves a prediction accuracy of 92.95%.The in-situ experiments conducted in coal mines demonstrate the system's reliability and monitoring functionality under both no-load and fullload conditions.This research provides an innovative self-powered condition monitoring solution and develops an efficient data-driven model,offering feasible online monitoring approaches for smart mine construction. 展开更多
关键词 intelligent safety monitoring SELF-POWERED magnetic modulation data driven model mining conveyor
在线阅读 下载PDF
Low‑Temperature Fabrication of Stable Black‑Phase CsPbI_(3) Perovskite Flexible Photodetectors Toward Wearable Health Monitoring
18
作者 Yingjie Zhao Yicheng Sun +8 位作者 Chaoxin Pei Xing Yin Xinyi Li Yi Hao Mengru Zhang Meng Yuan Jinglin Zhou Yu Chen Yanlin Song 《Nano-Micro Letters》 SCIE EI CAS 2025年第3期232-245,共14页
Flexible wearable optoelectronic devices fabricated fromorganic–inorganic hybrid perovskites significantly accelerate the developmentof portable energy,biomedicine,and sensing fields,but their poor thermal stabilityh... Flexible wearable optoelectronic devices fabricated fromorganic–inorganic hybrid perovskites significantly accelerate the developmentof portable energy,biomedicine,and sensing fields,but their poor thermal stabilityhinders further applications.Conversely,all-inorganic perovskites possessexcellent thermal stability,but black-phase all-inorganic perovskite filmusually requires high-temperature annealing steps,which increases energy consumptionand is not conducive to the fabrication of flexible wearable devices.In this work,an unprecedented low-temperature fabrication of stable blackphaseCsPbI3perovskite films is demonstrated by the in situ hydrolysis reactionof diphenylphosphinic chloride additive.The released diphenyl phosphateand chloride ions during the hydrolysis reaction significantly lower the phasetransition temperature and effectively passivate the defects in the perovskitefilms,yielding high-performance photodetectors with a responsivity of 42.1 AW−1 and a detectivity of 1.3×10^(14)Jones.Furthermore,high-fidelity imageand photoplethysmography sensors are demonstrated based on the fabricated flexible wearable photodetectors.This work provides a newperspective for the low-temperature fabrication of large-area all-inorganic perovskite flexible optoelectronic devices. 展开更多
关键词 In situ hydrolyzation Low-temperature processing All-inorganic perovskite Flexible photodetectors Health monitoring
在线阅读 下载PDF
GSeisRT: A Continental BDS/GNSS Point Positioning Engine for Wide-Area Seismic Monitoring in Real Time 被引量:1
19
作者 Jianghui Geng Kunlun Zhang +6 位作者 Shaoming Xin Jiang Guo David Mencin Tan Wang Sebastian Riquelme Elisabetta D’Anastasio Muhammad Al Kautsar 《Engineering》 2025年第4期57-69,共13页
Precise coseismic displacements in earthquake/tsunamic early warning are necessary to characterize earthquakes in real time in order to enable decision-makers to issue alerts for public safety.Real-time global navigat... Precise coseismic displacements in earthquake/tsunamic early warning are necessary to characterize earthquakes in real time in order to enable decision-makers to issue alerts for public safety.Real-time global navigation satellite systems(GNSSs)have been a valuable tool in monitoring seismic motions,allowing permanent displacement computation to be unambiguously achieved.As a valuable tool presented to the seismic commu nity,the GSeisRT software developed by Wuhan University(China)can realize multi-GNSS precise point positioning with ambiguity resolution(PPP-AR)and achieve centimeterlevel to sub-centimeter-level precision in real time.While the stable maintenance of a global precise point positioning(PPP)service is challenging,this software is capable of estimating satellite clocks and phase biases in real time using a regional GNSS network.This capability makes GSeisRT especially suitable for proprietary GNSS networks and,more importantly,the highest possible positio ning precision and reliability can be obtained.According to real-time results from the Network of the Americas,the mean root mean square(RMS)errors of kinematic PPP-AR over a 24 h span are as low as 1.2,1.3,and 3.0 cm in the east,north,and up components,respectively.Within the few minutes that span a typical seismic event,a horizontal displacement precision of 4 mm can be achieved.The positioning precision of the GSeisRT regional PPP/PPP-AR is 30%-40%higher than that of the global PPP/PPP-AR.Since 2019,GSeisRT has successfully recorded the static,dynamic,and peak ground displacements for the 2020Oaxaca,Mexico moment magnitude(Mw)7.4 event;the 2020 Lone Pine,California Mw 5.8 event;and the 2021 Qinghai,China Mw 7.3 event in real time.The resulting immediate magnitude estimates have an error of around 0.1 only.The GSeisRT software is open to the scientific community and has been applied by the China Earthquake Ne tworks Center,the EarthScope Consortium of the United States,the National Seismological Center of Chile,Institute of Geological and Nuclear Sciences Limited(GNS Science Te PūAo)of New Zealand,and the Geospatial Information Agency of Indonesia. 展开更多
关键词 Real-time Precise point positioning Multi global navigation satellite system Seismic monitoring Rapid earthquake response
在线阅读 下载PDF
Characterizing large deformation of soft rock tunnel using microseismic monitoring and numerical simulation 被引量:1
20
作者 Yuepeng Sun Nuwen Xu +4 位作者 Peiwei Xiao Zhiqiang Sun Huailiang Li Jun Liu Biao Li 《Journal of Rock Mechanics and Geotechnical Engineering》 2025年第1期309-322,共14页
Surrounding rock deterioration and large deformation have always been a significant difficulty in designing and constructing tunnels in soft rock.The key lies in real-time perception and quantitative assessment of the... Surrounding rock deterioration and large deformation have always been a significant difficulty in designing and constructing tunnels in soft rock.The key lies in real-time perception and quantitative assessment of the damaged area around the tunnel.An in situ microseismic(MS)monitoring system is established in the plateau soft tock tunnel.This technique facilitates spatiotemporal monitoring of the rock mass's fracturing expansion and squeezing deformation,which agree well with field convergence deformation results.The formation mechanisms of progressive failure evolution of soft rock tunnels were discussed and analyzed with MS data and numerical results.The results demonstrate that:(1)Localized stress concentration and layered rock result in significant asymmetry in micro-fractures propagation in the tunnel radial section.As excavation continues,the fracture extension area extends into the deep surrounding rockmass on the east side affected by the weak bedding;(2)Tunnel excavation and long-term deformation can induce tensile shear action on the rock mass,vertical tension fractures(account for 45%)exist in deep rockmass,which play a crucial role in controlling the macroscopic failure of surrounding rock;and(3)Based on the radiated MS energy,a three-dimensional model was created to visualize the damage zone of the tunnel surrounding rock.The model depicted varying degrees of damage,and three high damage zones were identified.Generally,the depth of high damage zone ranged from 4 m to 12 m.This study may be a valuable reference for the warning and controlling of large deformations in similar projects. 展开更多
关键词 Soft rock tunnel MS monitoring Progressive failure characteristic Excavation damage zone Failure mechanism
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部