The suppression of ablative Rayleigh–Taylor instability(ARTI)by a spatially modulated laser in inertial confinement fusion(ICF)is studied through numerical simulations.The results show that in the acceleration phase ...The suppression of ablative Rayleigh–Taylor instability(ARTI)by a spatially modulated laser in inertial confinement fusion(ICF)is studied through numerical simulations.The results show that in the acceleration phase of ICF implosion,the growth of ARTI can be suppressed by using a short-wavelength spatially modulated laser.The ARTI growth rate decreases as the wavelength of the spatially modulated laser decreases,and ARTI is completely suppressed after a certain wavelength has been reached.A spatially uniform laser is introduced to keep the state of motion of the implosion fluid consistent,and it is found that the proportion of the spatially modulated laser required for complete suppression of ARTI decreases as the wavelength continues to decrease.We also optimize the spatial intensity distribution of the spatially modulated laser.In addition,as the duration of the spatially modulated laser decreases,the proportion required for completely suppressing ARTI increases,but the required energy decreases.When the perturbation wavenumber decreases,the wavelength of the spatially modulated laser required for complete suppression of ARTI becomes longer.In the case of multimode perturbation,ARTI can also be significantly suppressed by a spatially modulated laser,and the perturbation amplitude can be reduced to less than 10% of that without a spatially modulated laser.We believe that the conclusions drawn from our simulations can provide the basis for new approaches to control ARTI in ICF.展开更多
This paper establishes an amplitude modulation heating model, simulating the far-field radiation of ELF/VLF signals generated by modulation heating, as well as the specific location and longitudinal extent of the radi...This paper establishes an amplitude modulation heating model, simulating the far-field radiation of ELF/VLF signals generated by modulation heating, as well as the specific location and longitudinal extent of the radiation source. We consider various modulation waveforms and find that square-wave modulation has the highest excitation efficiency for ELF/VLF signals, and that square-wave modulation with a smaller duty cycle(<50%) exhibits higher excitation efficiency for ELF/VLF signals, while the sin^(2)t waveform modulation yields the lowest proportion of harmonic energy in the generated signals. The amplitude of the second harmonic generated by the sin^(2)t waveform is less than one-tenth that of the fundamental frequency, and the energy of higher-frequency harmonics can be negligibly small compared with those of the fundamental wave. It is a challenging task to achieve a balance between enhancing the excitation efficiency of ELF/VLF signals and also suppressing harmonics generated by the modulated heating process. This is because the harmonics are correspondingly enhanced as the excitation efficiency of the signals is increased. However, we find that under conditions of varying effective radiant power and modulation frequency, as long as the modulation waveform is unchanged, the energy ratio between the fundamental frequency signal generated by modulated heating and each harmonic is relatively fixed, with changes only in signal intensity and the location of the radiation source zone. This implies that one can first select modulation waveforms that make the signal less prone to distortion, then increase the effective radiated power to enhance the signal strength, without concern for harmonic interference of the fundamental signal.展开更多
Significant two-way shape memory effect(TWSME)was achieved in single crystals of single-phase multielement Ni42-x Cu8 Cox Mn37 Ga13(8≤x≤12)alloys by performing thermomechanical training.However,anomalous dependence ...Significant two-way shape memory effect(TWSME)was achieved in single crystals of single-phase multielement Ni42-x Cu8 Cox Mn37 Ga13(8≤x≤12)alloys by performing thermomechanical training.However,anomalous dependence of the martensitic transformation temperature span on Co content was observed.Before training,quite a narrow temperature span of the martensitic transformation,nearly independent of the Co content,was observed in all single crystals.After training the temperature span was still narrow for 8≤x≤10.9 but was obviously expanded for 10.9<x≤12.High-resolution transmission electron microscopy revealed that at the atomic scale,there exists incommensurate modulated structure in the single phase single crystals,as evidenced by nonperiodic satellite spots in the selected area electronic diffraction patterns.Moreover,the modulated wave vector of the satellite spots was increased by higher Co contents.Combining first principal calculations it was considered that the incommensurate modulated structure originates from the formation of Co-Co pairs.After training arrays of ordered dislocations with the same Burgers vector were introduced for 8≤x≤10.9 but the network of dislocations was formed for 10.9<x≤12.Based on analysis of transmission electron microscopy,geometric phase,thermodynamics,and Landau theory,it was considered that the austenite/martensite phase interface was pinned by the network of dislocations,expanding the temperature span of the martensitic transformation.This work supplies new insights for understanding the microstructure and martensitic transformation of Ni-Mn-Ga-based alloys.展开更多
Correction to:Nano-Micro Letters(2025)17:117 https://doi.org/10.1007/s40820-025-01660-0 Following publication of the original article[1],the authors reported that the supplementary file needed to be updated because th...Correction to:Nano-Micro Letters(2025)17:117 https://doi.org/10.1007/s40820-025-01660-0 Following publication of the original article[1],the authors reported that the supplementary file needed to be updated because they mistakenly used the incorrect version.The original article[1]has been corrected.展开更多
Currently,the global 5G network,cloud computing,and data center industries are experiencing rapid development.The continuous growth of data center traffic has driven the vigorous progress in high-speed optical transce...Currently,the global 5G network,cloud computing,and data center industries are experiencing rapid development.The continuous growth of data center traffic has driven the vigorous progress in high-speed optical transceivers for optical interconnection within data centers.The electro-absorption modulated laser(EML),which is widely used in optical fiber communications,data centers,and high-speed data transmission systems,represents a high-performance photoelectric conversion device.Compared to traditional directly modulated lasers(DMLs),EMLs demonstrate lower frequency chirp and higher modulation bandwidth,enabling support for higher data rates and longer transmission distances.This article introduces the composition,working principles,manufacturing processes,and applications of EMLs.It reviews the progress on advanced indium phosphide(InP)-based EML devices from research institutions worldwide,while summarizing and comparing data transmission rates and key technical approaches across various studies.展开更多
Two-dimensional(2D)superconductors have attracted significant research interest due to their promising potential applications in optoelectronic and microelectronic devices.Herein,we employ first-principles calculation...Two-dimensional(2D)superconductors have attracted significant research interest due to their promising potential applications in optoelectronic and microelectronic devices.Herein,we employ first-principles calculations to predicted a new 2D conventional superconductor,Tc_(2)B_(2),demonstrating its stable structural configuration.Remarkably,under biaxial strain,the superconducting transition temperature(T_(c))of Tc_(2)B_(2)demonstrates a significant enhancement,achieving 19.5 K under 3%compressive strain and 9.2 K under 11%tensile strain.Our study reveals that strain-induced modifications in Fermi surface topology significantly enhance the Fermi surface nesting effect,which amplifies electron–phonon coupling interactions and consequently elevates Tc.Additionally,the presence of the Lifshitz transition results in a more pronounced rise in Tc under compressive strain compared to tensile strain.These insights offer important theoretical guidance for designing 2D superconductors with high-Tc through strain modulation.展开更多
This study investigates the dromion structure within the context of(2+1)-dimensional modulated positron-acoustic waves in a magnetoplasma consisting of inertial cold positrons and inertialess nonthermal hot electrons ...This study investigates the dromion structure within the context of(2+1)-dimensional modulated positron-acoustic waves in a magnetoplasma consisting of inertial cold positrons and inertialess nonthermal hot electrons and positrons as well as stationary positive ions.The reductive perturbation approach reduces the fluid governing equations to the plasma model to a Davey–Stewartson system.This study provides a detailed analysis of the influence of many related plasma parameters,including the density ratio of hot and cold positrons,the external magnetic field strength,the nonthermal parameter and the density ratio of electrons and cold positrons,on the growing rate of instability.Using the Hirota Bilinear method,it is found that the system supports some exact solutions,such as one-and two-dromion solutions.The change of plasma parameters significantly enhances the characteristics of dromion solutions.The elastic and inelastic collisions between two dromions are discussed at different times.The relevance of this study can help us to understand the various types of collision between energetic particles in confined plasma during the production of energy by thermonuclear fusion.展开更多
A new scheme of super-resolution optical fluctuation imaging(SOFI)is proposed to broaden its application in the high-order cumulant reconstruction by optimizing blinking characteristics,eliminating noise in raw data a...A new scheme of super-resolution optical fluctuation imaging(SOFI)is proposed to broaden its application in the high-order cumulant reconstruction by optimizing blinking characteristics,eliminating noise in raw data and applying multi-resolution analysis in cumulant reconstruction.A motor-driven rotating mask optical modulation system is designed to adjust the excitation lightfield and allows for fast deployment.Active-modulated fluorescence fluctuation superresolution microscopy with multi-resolution analysis(AMF-MRA-SOFI)demonstrates enhanced resolution ability and reconstruction quality in experiments performed on sample of conventional dyes,achieving a resolution of 100 nm in the fourth order compared to conventional SOFI reconstruction.Furthermore,our approach combining expansion super-resolution achieved a resolution at-57 nm.展开更多
Femtosecond laser processing is an important machining method for micro-optical components such as Fresnel zone plate(FZP).However,the low processing efficiency of the femtosecond laser restricts its application.Here,...Femtosecond laser processing is an important machining method for micro-optical components such as Fresnel zone plate(FZP).However,the low processing efficiency of the femtosecond laser restricts its application.Here,a femtosecond laser Bessel beam is proposed to process micro-FZP,which is modulated from a Gaussian beam to a Bessel annular beam.The processing time for FZP with an outer diameter of 60μm is reduced from 30 min to 1.5 min on an important semiconductor material gallium arsenide(GaAs),which significantly improves the processing efficiency.In the modulation process,a central ablation hole that has an adverse effect on the diffraction performance is produced,and the adverse effect is eliminated by superimposing the blazed grating hologram.Meanwhile,the FZP machined by spatial light modulator(SLM)has good morphology and higher diffraction efficiency,which provides a strong guarantee for the application of micro-FZP in computed tomography and solar photovoltaic cells.展开更多
The classical-quantum analogue offers a new platform for exploring extreme dynamic control of mechanical systems.In this work,the concept of the stimulated adiabatic passage of quantum states is extended to mechanical...The classical-quantum analogue offers a new platform for exploring extreme dynamic control of mechanical systems.In this work,the concept of the stimulated adiabatic passage of quantum states is extended to mechanical systems for achieving unidirectional energy transportation.The mechanical analog of stimulated adiabatic passage is realized in three mechanical resonators coupled with the time-varying stiffness,which are delicately modulated to mimic the selective population of quantum states.Based on the tight-binding approximation,an analytical model for the classical-quantum analogue of the adiabatic passage effect is established to realize the one-way energy transfer control.Numerical results demonstrate that the vibration energy acquired from an initially excited resonator can be transferred to the target one via an intermediate resonator,while flow in the reverse direction is prohibited due to energy localization in the intermediate resonator.The model holds application potentials in energy suppression and harvesting,and offers promising prospects for unidirectional wave and vibration control.展开更多
CO_(2)electroreduction(CO_(2)RR)represents a promising negative-carbon technology,which is in urgent need for efficient and high-selectivity catalysts.Here,a support control strategy is employed for precise surface en...CO_(2)electroreduction(CO_(2)RR)represents a promising negative-carbon technology,which is in urgent need for efficient and high-selectivity catalysts.Here,a support control strategy is employed for precise surface engineering of charge-asymmetry nanocluster catalyst(CuZnSCN),in which zinc and copper atoms together form a metal cluster loaded on sulfur and nitrogen co-etched carbon matrix.The synergistic promotion mechanism of CO_(2)RR by Cu–Zn atom interactions and sulfur–nitrogen atom doping was investigated.A CO partial current density of 74.1 mA cm^(-2)was achieved in an alkaline electrolyte,as well as a considerable CO Faraday efficiency of 97.7%.In situ XAS(X-ray absorption spectroscopy)showed that the stabilization of Cu^(+)and Zn^(2+)species in the nanoclusters and doped sulfur atoms during the CO_(2)RR process contributes to the sustained adsorption of protons and the generation and conversion of the CO.This work verifies the possibility of metal-support and intermetallic interactions to synergistically enhance electrochemical catalytic performance and provides ideas for further bimetallic cluster catalyst development.展开更多
Objective: A dosimetric study was performed to evaluate the performance of volumetric modulated arc radiotherapy with RapidArc on locally advanced nasopharyngeal carcinoma (NPC). Methods: The CT scan data sets of 20 p...Objective: A dosimetric study was performed to evaluate the performance of volumetric modulated arc radiotherapy with RapidArc on locally advanced nasopharyngeal carcinoma (NPC). Methods: The CT scan data sets of 20 patients of locally advanced NPC were selected randomly. The plans were managed using volumetric modulated arc with RapidArc and fixed nine-field coplanar dynamic intensity-modulated radiotherapy (IMRT) for these patients. The dosimetry of the planning target volumes (PTV), the organs at risk (OARs) and the healthy tissue were evaluated. The dose prescription was set to 70 Gy to the primary tumor and 60 Gy to the clinical target volumes (CTV) in 33 fractions. Each fraction applied daily, five fractions per week. The monitor unit (MU) values and the delivery time were scored to evaluate the expected treatment efficiency. Results: Both techniques had reached clinical treatment’s requirement. The mean dose (Dmean), maximum dose (Dmax) and minimum dose (Dmin) in RapidArc and fixed field IMRT for PTV were 68.4±0.6 Gy, 74.8±0.9 Gy and 56.8±1.1 Gy; and 67.6±0.6 Gy, 73.8±0.4 Gy and 57.5±0.6 Gy (P<0.05), respectively. Homogeneity index was 78.85±1.29 in RapidArc and 80.34±0.54 (P<0.05) in IMRT. The conformity index (CI: 95%) was 0.78±0.01 for both techniques (P>0.05). Compared to IMRT, RapidArc allowed a reduction of Dmean to the brain stem, mandible and optic nerves of 14.1% (P<0.05), 5.6% (P<0.05) and 12.2% (P<0.05), respectively. For the healthy tissue and the whole absorbed dose, Dmean of RapidArc was reduced by 3.6% (P<0.05), and 3.7% (P<0.05), respectively. The Dmean to the parotids, the spinal cord and the lens had no statistical difference among them. The mean MU values of RapidArc and IMRT were 550 and 1,379. The mean treatment time of RapidArc and IMRT was 165 s and 447 s. Compared to IMRT, the delivery time and the MU values of RapidArc were reduced by 63% and 60%, respectively. Conclusion: For locally advanced NPC, both RapidArc and IMRT reached the clinic requirement. The target volume coverage was similar for the different techniques. The RapidArc technique showed some improvements in OARs and other tissue sparing while using reduced MUs and delivery time.展开更多
AIM To analyse clinical and dosimetric results of helical tomotherapy(HT)and volumetric modulated arc therapy(VMAT)in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT an...AIM To analyse clinical and dosimetric results of helical tomotherapy(HT)and volumetric modulated arc therapy(VMAT)in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT and 42 VMAT).Dose were 63.8 Gy(HT)and 63.2 Gy(VMAT)in the tumour bed,52.2 Gy in the breast,50.4 Gy in supraclavicular nodes(SCN)and internal mammary chain(IMC)with HT and 52.2 Gy and 49.3 Gy in IMC and SCN with VMAT in 29 fractions.Margins to particle tracking velocimetry were greater in the VMAT cohort(7 mm vs 5 mm).RESULTS For the HT cohort,the coverage of clinical target volumes was as follows:Tumour bed:99.4%±2.4%;breast:98.4%±4.3%;SCN:99.5%±1.2%;IMC:96.5%±13.9%.For the VMAT cohort,the coverage was as follows:Tumour bed:99.7%±0.5%,breast:99.3%±0.7%;SCN:99.6%±1.4%;IMC:99.3%±3%.For ipsilateral lung,Dmean and V20 were 13.6±1.2 Gy,21.1%±5%(HT)and 13.6±1.4 Gy,20.1%±3.2%(VMAT).Dmean and V30 of the heart were 7.4±1.4 Gy,1%±1%(HT)and 10.3±4.2 Gy,2.5%±3.9%(VMAT).For controlateral breast Dmean was 3.6±0.2 Gy(HT)and 4.6±0.9 Gy(VMAT).Acute skin toxicity grade 3 was 5%in the two cohorts.CONCLUSION HT and VMAT in complex adjuvant breast irradiation allow a good coverage of target volumes with an acceptable acute tolerance.A longer follow-up is needed to assess the impact of low doses to healthy tissues.展开更多
In this study,we explored a one-step direct synthesis of NH3 under mild experimental conditions utilizing pulse-modulated microwave plasma technology at atmospheric pressure.At a substantial gas flow rate,a microwave ...In this study,we explored a one-step direct synthesis of NH3 under mild experimental conditions utilizing pulse-modulated microwave plasma technology at atmospheric pressure.At a substantial gas flow rate,a microwave plasma jet was formed and the microwave-assisted ammonia synthesis can be realized.Impacts of various parameters including the gas flow rate,gas component,microwave absorbed power,pulse modulation frequency,and pulse duty cycle on ammonia synthesis were systematically investigated.To indicate the reaction path of ammonia synthesis,the distributions of both the gas temperature and active species were also studied using optical emission spectra technology.It is found that a considerable amount of ammonia was directly synthesized without involvement of any catalysts,the highest ammonia production rate and energy efficiency(EE),up to 2.93μmol·min^(-1) and 6.64×10^(-2)g·(k W·h)^(-1),respectively,were achieved under low microwave power of 84.42 W.The duty cycle has obvious influences on the synthesis efficiency,compared to a duty cycle of 80%,the ammonia synthesis rate,EE and nitrogen conversion decreased by about 22%at a duty cycle of 100%.This finding underscores the significance of incorporating pulse modulation in the microwave discharge process for ammonia synthesis.Furthermore,it was found that vibrational excitation of microwave plasma has a significant driving effect on ammonia synthesis.展开更多
We investigate the approximating capability of Markov modulated Poisson processes (MMPP) for modeling multifractal Internet traffic. The choice of MMPP is motivated by its ability to capture the variability and correl...We investigate the approximating capability of Markov modulated Poisson processes (MMPP) for modeling multifractal Internet traffic. The choice of MMPP is motivated by its ability to capture the variability and correlation in moderate time scales while being analytically tractable. Important statistics of traffic burstiness are described and a customized moment-based fitting procedure of MMPP to traffic traces is presented. Our methodology of doing this is to examine whether the MMPP can be used to predict the performance of a queue to which MMPP sample paths and measured traffic traces are fed for comparison respectively, in addition to the goodness-of-fit test of MMPP. Numerical results and simulations show that the fitted MMPP can approximate multifractal traffic quite well, i.e. accurately predict the queueing performance.展开更多
Objective The aim of this study was to compare the long-term local control, overall survival, and late toxicities of positron emission tomography/computed tomography (PET/CT)-guided dose escalation radio- therapy ve...Objective The aim of this study was to compare the long-term local control, overall survival, and late toxicities of positron emission tomography/computed tomography (PET/CT)-guided dose escalation radio- therapy versus conventional radiotherapy in the concurrent chemoradiotherapy treatment of locally ad- vanced nasopharyngeal carcinoma (NPC). Methods Atotal of 48 patients with stage IIl-IVa NPC were recruited and randomly administered PET/CT- guided dose escalation chemoradiotherapy (group A) or conventional chemoradiotherapy (group B). The dose-escalation radiotherapy was performed using the simultaneous modulated accelerated radiotherapy technique at prescribed doses of 77 gray (Gy) in 32 fractions (f) to the gross target volume (GTV): planning target volume (PTV) 1 received 64 Gy/32 f, while PTV2 received 54.4 Gy/32 f. Patients in group B received uniform-dose intensity-modulated radiotherapy, PTV1 received 70 Gy/35 f and PTV2 received 58 Gy/29 f. Concurrent chemotherapy consisted of cisplatin [20 mg/m2 intravenous (IV) on days 1-4] and docetaxel (75 mg/m2 IV on days 1 and 8) administered during treatment weeks 1 and 4. All patients received 2-4 cycles of adjuvant chemotherapy of the same dose and drug regimen. Results The use of fluorine-18-fluorodeoxyglucose (18F-FDG) PET/CT significantly reduced the treat- ment volume delineation of the GTV in 83.3% (20/24) of patients. The 5-year local recurrence-free survival rates of the two groups were 100% and 79.2%, respectively (P = 0.019). The 5-year disease free survival (DFS) rates were 95.8% and 75.0%, respectively (P = 0.018). The 5-year local progression-free survival and DFS rates were significantly different. The 5-year overall survival (OS) rates were 95.8% and 79.2%, re- spectively. Differences in OS improvement were insignificant (P = 0.079). Late toxicities were similar in the two groups. The most common late toxicities of the two arms were grade 1-2 skin dystrophy, xerostomia, subcutaneous fibrosis, and hearing loss. There were no cases of grade 4 late toxicity. Conclusion The use of 18F-FDG PET/CT-guided dose escalation radiotherapy is well tolerated and can reduce local recurrence rates for patients with locally advanced NPC compared to conventional chemora- diotherapy.展开更多
Metal Fe/Pd compositionally modulated films(CMFs) were prepared by vapour depo- sition from two sources onto glass substrate under vacuum.The modulation and crystal structures of the films were examined by X-ray diffr...Metal Fe/Pd compositionally modulated films(CMFs) were prepared by vapour depo- sition from two sources onto glass substrate under vacuum.The modulation and crystal structures of the films were examined by X-ray diffraction.The magnetic properties were determined by vibrating sample magnetometer.The Pd layers in the Fe/Pd CMFs are of fcc structure,and the Fe layer structure transits from bcc into amorphous,state with decreasing thickness of Fe layer.The dependence of specific saturation magnetization on thickness of Fe layers has also been discussed.展开更多
OBJECTIVE To evaluate the clinical efficacy and toxicities of simultaneous modulated accelerated radiotherapy (SMART) and concurrent chemotherapy for locally advanced nasopharyngeal carcinoma. METHODS Eightyseven pa...OBJECTIVE To evaluate the clinical efficacy and toxicities of simultaneous modulated accelerated radiotherapy (SMART) and concurrent chemotherapy for locally advanced nasopharyngeal carcinoma. METHODS Eightyseven patients with nasopharyngeal carcinoma received SMART from April 2002 to September 2006. According to the UICC staging system, 30 patients were diagnosed as stage IIb, 42 patients stage III, 13 patients stage IVa and 2 patients stage IVb. The intensitymodulated radiotherapy was delivered with the "step and shoot" SMART technique with the prescribed dose of 66-76 Gy (2.2-2.4 Gy/day) to the gross tumor volume (GTV) and positive neck lymph nodes (GTVLN), with 60 Gy (2.0 Gy/day) to the highrisk clinical target volume (CTV1), encompassing the area around the nasopharynx and the upper neck, and with 54 Gy (1.8 Gy/day) to the lowrisk clinical target volume (CTV2), including the lower neck and supraclavicular area. Among all the patients, 31 received 2 cycles of SMART concurrently with 5 fluorouracil (5-Fu) and cisplatin (the FP group) and 56 received 2 cycles of concurrent cisplatin. All the patients received 3 to 4 cycles of adjuvant combination chemotherapy of cisplatin and 5fluorouracil starting from the 1st month after completion of SMART. RESULTS With a median follow up of 59 months (ranging from 19 to 85 months), the 1, 2 and 3year overall survival rates were 100%, 94.6% and 91.3% respectively. Acute mucositis and pharyngitis were more frequently observed in the FP group than in the cisplatin group. CONCLUSION SMART technique provides an excellent opportunity to spare normal tissue and is probably more biologically effective. Combination of single cisplatin was more tolerable.展开更多
AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC ...AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC were selected, including 5 cases located in the cervical, the upper, the middle and the lower thorax, respectively. Five plans were generated with the eclipse planning sys- tem: three using c-IMRT with 5 fields (5F), 7 fields (7F) and 9 fields (gF), and two using VMAT with a single arc (1A) and double arcs (2A). The treatment plans were designed to deliver a dose of 60 Gy to the plan-ning target volume (PTV) with the same constrains in a 2.0 Gy daily fraction, 5 d a week. Plans were normal- ized to 95% of the PTV that received 100% of the pre- scribed dose. We examined the dose-volume histogram parameters of PTV and the organs at risk (OAR) such as lungs, spinal cord and heart. Monitor units (MU) and normal tissue complication probability (NTCP) of OAR were also reported. RESULTS: Both c-IMRT and VMAT plans resulted in abundant dose coverage of PTV for EC of different Io- cations. The dose conformity to PTV was improved as the number of field in c-IMRT or rotating arc in VMAT was increased. The doses to PTV and OAR in VMAT plans were not statistically different in comparison with c-IMRT plans, with the following exceptions: in cervical and upper thoracic EC, the conformity index (CI) was higher in VMAT (1A 0.78 and 2A 0.8) than in c-IMRT (5F 0.62, 7F 0.66 and 9F 0.73) and homogeneity was slightly better in c-IMRT (7F 1.09 and 9F 1.07) than in VMAT (1A 1,1 and 2A 1.09), Lung V30 was lower in VMAT (1A 12.52 and 2A 12.29) than in c-IMRT (7F 14.35 and 9F 14.81). The humeral head doses were significantly increased in VMAT as against c-IMRT. In the middle and lower thoracic EC, CI in VMAT (1A 0.76 and 2A 0.74) was higher than in c-IMRT (5F 0.63 Gy and 7F 0.67 Gy), and homogeneity was almost similar between VMAT and c-IMRT. V20 (2A 21.49 Gy vs 7F 24.59 Gy and 9F 24.16 Gy) and V30 (2A 9.73 Gy vs 5F 12.61 Gy, 7F 11.5 Gy and 9F 11.37 Gy) of lungs in VMAT were lower than in c-IMRT, but low doses to lungs (V5 and Vl0) were increased. V30 (1A 48.12 Gy vs 5F 59.2 Gy, 7F 58.59 Gy and 9F 57.2 Gy), V40 and V50 of heart in VMAT was lower than in c-IMRT. MUs in VMAT plans were significantly reduced in comparison with c-IMRT, maximum doses to the spinal cord and mean doses of lungs were similar between the two techniques. NTCP of spinal cord was 0 for all cases. NTCP of lungs and heart in VMAT were lower than in c-IMRT. The advantage of VMAT plan was enhanced by doubling the arc. CONCLUSION: Compared with c-IMRT, VMAT, especial- ly the 2A, slightly improves the OAR dose sparing, such as lungs and heart, and reduces NTCP and MU with a better PTV coverage.展开更多
基金supported by the National Natural Science Foundation of China(NSFC)(Nos.12074399,12204500,and 12004403)the Key Projects of Intergovernmental International Scientific and Technological Innovation Cooperation(No.2021YFE0116700)+1 种基金the Shanghai Natural Science Foundation(No.20ZR1464400)the Shanghai Sailing Program(No.22YF1455300).
文摘The suppression of ablative Rayleigh–Taylor instability(ARTI)by a spatially modulated laser in inertial confinement fusion(ICF)is studied through numerical simulations.The results show that in the acceleration phase of ICF implosion,the growth of ARTI can be suppressed by using a short-wavelength spatially modulated laser.The ARTI growth rate decreases as the wavelength of the spatially modulated laser decreases,and ARTI is completely suppressed after a certain wavelength has been reached.A spatially uniform laser is introduced to keep the state of motion of the implosion fluid consistent,and it is found that the proportion of the spatially modulated laser required for complete suppression of ARTI decreases as the wavelength continues to decrease.We also optimize the spatial intensity distribution of the spatially modulated laser.In addition,as the duration of the spatially modulated laser decreases,the proportion required for completely suppressing ARTI increases,but the required energy decreases.When the perturbation wavenumber decreases,the wavelength of the spatially modulated laser required for complete suppression of ARTI becomes longer.In the case of multimode perturbation,ARTI can also be significantly suppressed by a spatially modulated laser,and the perturbation amplitude can be reduced to less than 10% of that without a spatially modulated laser.We believe that the conclusions drawn from our simulations can provide the basis for new approaches to control ARTI in ICF.
基金supported by the National Key R&D Program of China (No. 2022YFE0204100)the National Natural Science Foundation of China (12205067 and 12375199)the Fundamental Research Funds for the Central Universities (Grant No. HIT.OCEF. 2022036)。
文摘This paper establishes an amplitude modulation heating model, simulating the far-field radiation of ELF/VLF signals generated by modulation heating, as well as the specific location and longitudinal extent of the radiation source. We consider various modulation waveforms and find that square-wave modulation has the highest excitation efficiency for ELF/VLF signals, and that square-wave modulation with a smaller duty cycle(<50%) exhibits higher excitation efficiency for ELF/VLF signals, while the sin^(2)t waveform modulation yields the lowest proportion of harmonic energy in the generated signals. The amplitude of the second harmonic generated by the sin^(2)t waveform is less than one-tenth that of the fundamental frequency, and the energy of higher-frequency harmonics can be negligibly small compared with those of the fundamental wave. It is a challenging task to achieve a balance between enhancing the excitation efficiency of ELF/VLF signals and also suppressing harmonics generated by the modulated heating process. This is because the harmonics are correspondingly enhanced as the excitation efficiency of the signals is increased. However, we find that under conditions of varying effective radiant power and modulation frequency, as long as the modulation waveform is unchanged, the energy ratio between the fundamental frequency signal generated by modulated heating and each harmonic is relatively fixed, with changes only in signal intensity and the location of the radiation source zone. This implies that one can first select modulation waveforms that make the signal less prone to distortion, then increase the effective radiated power to enhance the signal strength, without concern for harmonic interference of the fundamental signal.
基金support from the National Key Research and Development Program of China(Grant No.2021YFB3501402)the National Natural Science Foundation of China(Grant Nos.52250313 and 52121001)Yang Liu and Chen Si acknowledge financial support from the National Natural Science Foundation of China(Grant No.12274013).
文摘Significant two-way shape memory effect(TWSME)was achieved in single crystals of single-phase multielement Ni42-x Cu8 Cox Mn37 Ga13(8≤x≤12)alloys by performing thermomechanical training.However,anomalous dependence of the martensitic transformation temperature span on Co content was observed.Before training,quite a narrow temperature span of the martensitic transformation,nearly independent of the Co content,was observed in all single crystals.After training the temperature span was still narrow for 8≤x≤10.9 but was obviously expanded for 10.9<x≤12.High-resolution transmission electron microscopy revealed that at the atomic scale,there exists incommensurate modulated structure in the single phase single crystals,as evidenced by nonperiodic satellite spots in the selected area electronic diffraction patterns.Moreover,the modulated wave vector of the satellite spots was increased by higher Co contents.Combining first principal calculations it was considered that the incommensurate modulated structure originates from the formation of Co-Co pairs.After training arrays of ordered dislocations with the same Burgers vector were introduced for 8≤x≤10.9 but the network of dislocations was formed for 10.9<x≤12.Based on analysis of transmission electron microscopy,geometric phase,thermodynamics,and Landau theory,it was considered that the austenite/martensite phase interface was pinned by the network of dislocations,expanding the temperature span of the martensitic transformation.This work supplies new insights for understanding the microstructure and martensitic transformation of Ni-Mn-Ga-based alloys.
文摘Correction to:Nano-Micro Letters(2025)17:117 https://doi.org/10.1007/s40820-025-01660-0 Following publication of the original article[1],the authors reported that the supplementary file needed to be updated because they mistakenly used the incorrect version.The original article[1]has been corrected.
基金supported by the Strategic Priority Research Program of CAS(Grant No.XDB43020202)the Natural Science Foundation of China(Grant Nos.61934007,62274153,62090053).
文摘Currently,the global 5G network,cloud computing,and data center industries are experiencing rapid development.The continuous growth of data center traffic has driven the vigorous progress in high-speed optical transceivers for optical interconnection within data centers.The electro-absorption modulated laser(EML),which is widely used in optical fiber communications,data centers,and high-speed data transmission systems,represents a high-performance photoelectric conversion device.Compared to traditional directly modulated lasers(DMLs),EMLs demonstrate lower frequency chirp and higher modulation bandwidth,enabling support for higher data rates and longer transmission distances.This article introduces the composition,working principles,manufacturing processes,and applications of EMLs.It reviews the progress on advanced indium phosphide(InP)-based EML devices from research institutions worldwide,while summarizing and comparing data transmission rates and key technical approaches across various studies.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.12274169,12122405,and 52072188)the National Key Research and Development Program of China(Grant No.2022YFA1402304)+1 种基金the Program for Science and Technology Innovation Team in Zhejiang Province,China(Grant No.2021R01004)the Fundamental Research Funds for the Central Universities.
文摘Two-dimensional(2D)superconductors have attracted significant research interest due to their promising potential applications in optoelectronic and microelectronic devices.Herein,we employ first-principles calculations to predicted a new 2D conventional superconductor,Tc_(2)B_(2),demonstrating its stable structural configuration.Remarkably,under biaxial strain,the superconducting transition temperature(T_(c))of Tc_(2)B_(2)demonstrates a significant enhancement,achieving 19.5 K under 3%compressive strain and 9.2 K under 11%tensile strain.Our study reveals that strain-induced modifications in Fermi surface topology significantly enhance the Fermi surface nesting effect,which amplifies electron–phonon coupling interactions and consequently elevates Tc.Additionally,the presence of the Lifshitz transition results in a more pronounced rise in Tc under compressive strain compared to tensile strain.These insights offer important theoretical guidance for designing 2D superconductors with high-Tc through strain modulation.
基金The authors extend their appreciation to the Deanship of Scientific Research and Libraries in Princess Nourah bint Abdulrahman University for funding this research work through the Research Group project under Grant No.(RG-1445-0005).
文摘This study investigates the dromion structure within the context of(2+1)-dimensional modulated positron-acoustic waves in a magnetoplasma consisting of inertial cold positrons and inertialess nonthermal hot electrons and positrons as well as stationary positive ions.The reductive perturbation approach reduces the fluid governing equations to the plasma model to a Davey–Stewartson system.This study provides a detailed analysis of the influence of many related plasma parameters,including the density ratio of hot and cold positrons,the external magnetic field strength,the nonthermal parameter and the density ratio of electrons and cold positrons,on the growing rate of instability.Using the Hirota Bilinear method,it is found that the system supports some exact solutions,such as one-and two-dromion solutions.The change of plasma parameters significantly enhances the characteristics of dromion solutions.The elastic and inelastic collisions between two dromions are discussed at different times.The relevance of this study can help us to understand the various types of collision between energetic particles in confined plasma during the production of energy by thermonuclear fusion.
基金supported by the National Natural Science Foundation of China(62175034,62175036,32271510)the National Key R&D Program of China(2021YFF0502900)+2 种基金the Science and Technology Research Program of Shanghai(Grant No.19DZ2282100)the Shanghai Key Laboratory of Metasurfaces for Light Manipulation(23dz2260100)the Shanghai Engineering Technology Research Center of Hair Medicine(19DZ2250500).
文摘A new scheme of super-resolution optical fluctuation imaging(SOFI)is proposed to broaden its application in the high-order cumulant reconstruction by optimizing blinking characteristics,eliminating noise in raw data and applying multi-resolution analysis in cumulant reconstruction.A motor-driven rotating mask optical modulation system is designed to adjust the excitation lightfield and allows for fast deployment.Active-modulated fluorescence fluctuation superresolution microscopy with multi-resolution analysis(AMF-MRA-SOFI)demonstrates enhanced resolution ability and reconstruction quality in experiments performed on sample of conventional dyes,achieving a resolution of 100 nm in the fourth order compared to conventional SOFI reconstruction.Furthermore,our approach combining expansion super-resolution achieved a resolution at-57 nm.
基金Projects(51875584,51875585,51975590)supported by the National Natural Science Foundation of China。
文摘Femtosecond laser processing is an important machining method for micro-optical components such as Fresnel zone plate(FZP).However,the low processing efficiency of the femtosecond laser restricts its application.Here,a femtosecond laser Bessel beam is proposed to process micro-FZP,which is modulated from a Gaussian beam to a Bessel annular beam.The processing time for FZP with an outer diameter of 60μm is reduced from 30 min to 1.5 min on an important semiconductor material gallium arsenide(GaAs),which significantly improves the processing efficiency.In the modulation process,a central ablation hole that has an adverse effect on the diffraction performance is produced,and the adverse effect is eliminated by superimposing the blazed grating hologram.Meanwhile,the FZP machined by spatial light modulator(SLM)has good morphology and higher diffraction efficiency,which provides a strong guarantee for the application of micro-FZP in computed tomography and solar photovoltaic cells.
基金supported by the National Key R&D Program of China(2024YFB3408700 and 2024YFB3408702)the National Natural Science Foundation of China(Grant Numbers 12225203,12402100,11991030,11991033,11622215,and 11872111)the 111 project(Grant Number B16003).
文摘The classical-quantum analogue offers a new platform for exploring extreme dynamic control of mechanical systems.In this work,the concept of the stimulated adiabatic passage of quantum states is extended to mechanical systems for achieving unidirectional energy transportation.The mechanical analog of stimulated adiabatic passage is realized in three mechanical resonators coupled with the time-varying stiffness,which are delicately modulated to mimic the selective population of quantum states.Based on the tight-binding approximation,an analytical model for the classical-quantum analogue of the adiabatic passage effect is established to realize the one-way energy transfer control.Numerical results demonstrate that the vibration energy acquired from an initially excited resonator can be transferred to the target one via an intermediate resonator,while flow in the reverse direction is prohibited due to energy localization in the intermediate resonator.The model holds application potentials in energy suppression and harvesting,and offers promising prospects for unidirectional wave and vibration control.
基金Supported by Shantou University Medical College Clinical Research Enhancement Initiative,and Research and Travel Grants from the Science and Technology Key Project of Shantou City,China,2012,No.2012-165-131
文摘AIM: To establish the feasibility of simultaneous modulated accelerated radiation therapy (SMART) in esophageal cancer (EC).
基金financially supported by the National Natural Science Foundation of China(No.22375019)Beijing Institute of Technology Research Fund Program for Young Scholars(No.3090012221909)
文摘CO_(2)electroreduction(CO_(2)RR)represents a promising negative-carbon technology,which is in urgent need for efficient and high-selectivity catalysts.Here,a support control strategy is employed for precise surface engineering of charge-asymmetry nanocluster catalyst(CuZnSCN),in which zinc and copper atoms together form a metal cluster loaded on sulfur and nitrogen co-etched carbon matrix.The synergistic promotion mechanism of CO_(2)RR by Cu–Zn atom interactions and sulfur–nitrogen atom doping was investigated.A CO partial current density of 74.1 mA cm^(-2)was achieved in an alkaline electrolyte,as well as a considerable CO Faraday efficiency of 97.7%.In situ XAS(X-ray absorption spectroscopy)showed that the stabilization of Cu^(+)and Zn^(2+)species in the nanoclusters and doped sulfur atoms during the CO_(2)RR process contributes to the sustained adsorption of protons and the generation and conversion of the CO.This work verifies the possibility of metal-support and intermetallic interactions to synergistically enhance electrochemical catalytic performance and provides ideas for further bimetallic cluster catalyst development.
文摘Objective: A dosimetric study was performed to evaluate the performance of volumetric modulated arc radiotherapy with RapidArc on locally advanced nasopharyngeal carcinoma (NPC). Methods: The CT scan data sets of 20 patients of locally advanced NPC were selected randomly. The plans were managed using volumetric modulated arc with RapidArc and fixed nine-field coplanar dynamic intensity-modulated radiotherapy (IMRT) for these patients. The dosimetry of the planning target volumes (PTV), the organs at risk (OARs) and the healthy tissue were evaluated. The dose prescription was set to 70 Gy to the primary tumor and 60 Gy to the clinical target volumes (CTV) in 33 fractions. Each fraction applied daily, five fractions per week. The monitor unit (MU) values and the delivery time were scored to evaluate the expected treatment efficiency. Results: Both techniques had reached clinical treatment’s requirement. The mean dose (Dmean), maximum dose (Dmax) and minimum dose (Dmin) in RapidArc and fixed field IMRT for PTV were 68.4±0.6 Gy, 74.8±0.9 Gy and 56.8±1.1 Gy; and 67.6±0.6 Gy, 73.8±0.4 Gy and 57.5±0.6 Gy (P<0.05), respectively. Homogeneity index was 78.85±1.29 in RapidArc and 80.34±0.54 (P<0.05) in IMRT. The conformity index (CI: 95%) was 0.78±0.01 for both techniques (P>0.05). Compared to IMRT, RapidArc allowed a reduction of Dmean to the brain stem, mandible and optic nerves of 14.1% (P<0.05), 5.6% (P<0.05) and 12.2% (P<0.05), respectively. For the healthy tissue and the whole absorbed dose, Dmean of RapidArc was reduced by 3.6% (P<0.05), and 3.7% (P<0.05), respectively. The Dmean to the parotids, the spinal cord and the lens had no statistical difference among them. The mean MU values of RapidArc and IMRT were 550 and 1,379. The mean treatment time of RapidArc and IMRT was 165 s and 447 s. Compared to IMRT, the delivery time and the MU values of RapidArc were reduced by 63% and 60%, respectively. Conclusion: For locally advanced NPC, both RapidArc and IMRT reached the clinic requirement. The target volume coverage was similar for the different techniques. The RapidArc technique showed some improvements in OARs and other tissue sparing while using reduced MUs and delivery time.
文摘AIM To analyse clinical and dosimetric results of helical tomotherapy(HT)and volumetric modulated arc therapy(VMAT)in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT and 42 VMAT).Dose were 63.8 Gy(HT)and 63.2 Gy(VMAT)in the tumour bed,52.2 Gy in the breast,50.4 Gy in supraclavicular nodes(SCN)and internal mammary chain(IMC)with HT and 52.2 Gy and 49.3 Gy in IMC and SCN with VMAT in 29 fractions.Margins to particle tracking velocimetry were greater in the VMAT cohort(7 mm vs 5 mm).RESULTS For the HT cohort,the coverage of clinical target volumes was as follows:Tumour bed:99.4%±2.4%;breast:98.4%±4.3%;SCN:99.5%±1.2%;IMC:96.5%±13.9%.For the VMAT cohort,the coverage was as follows:Tumour bed:99.7%±0.5%,breast:99.3%±0.7%;SCN:99.6%±1.4%;IMC:99.3%±3%.For ipsilateral lung,Dmean and V20 were 13.6±1.2 Gy,21.1%±5%(HT)and 13.6±1.4 Gy,20.1%±3.2%(VMAT).Dmean and V30 of the heart were 7.4±1.4 Gy,1%±1%(HT)and 10.3±4.2 Gy,2.5%±3.9%(VMAT).For controlateral breast Dmean was 3.6±0.2 Gy(HT)and 4.6±0.9 Gy(VMAT).Acute skin toxicity grade 3 was 5%in the two cohorts.CONCLUSION HT and VMAT in complex adjuvant breast irradiation allow a good coverage of target volumes with an acceptable acute tolerance.A longer follow-up is needed to assess the impact of low doses to healthy tissues.
基金supported by National Natural Science Foundation of China(Nos.52077026,51977023,52177126 and 12475253)the Fundamental Research Funds for the Central Universities(No.DUT23YG227)the Dalian Life&Health Guiding Project(No.2023ZXYG34)。
文摘In this study,we explored a one-step direct synthesis of NH3 under mild experimental conditions utilizing pulse-modulated microwave plasma technology at atmospheric pressure.At a substantial gas flow rate,a microwave plasma jet was formed and the microwave-assisted ammonia synthesis can be realized.Impacts of various parameters including the gas flow rate,gas component,microwave absorbed power,pulse modulation frequency,and pulse duty cycle on ammonia synthesis were systematically investigated.To indicate the reaction path of ammonia synthesis,the distributions of both the gas temperature and active species were also studied using optical emission spectra technology.It is found that a considerable amount of ammonia was directly synthesized without involvement of any catalysts,the highest ammonia production rate and energy efficiency(EE),up to 2.93μmol·min^(-1) and 6.64×10^(-2)g·(k W·h)^(-1),respectively,were achieved under low microwave power of 84.42 W.The duty cycle has obvious influences on the synthesis efficiency,compared to a duty cycle of 80%,the ammonia synthesis rate,EE and nitrogen conversion decreased by about 22%at a duty cycle of 100%.This finding underscores the significance of incorporating pulse modulation in the microwave discharge process for ammonia synthesis.Furthermore,it was found that vibrational excitation of microwave plasma has a significant driving effect on ammonia synthesis.
文摘We investigate the approximating capability of Markov modulated Poisson processes (MMPP) for modeling multifractal Internet traffic. The choice of MMPP is motivated by its ability to capture the variability and correlation in moderate time scales while being analytically tractable. Important statistics of traffic burstiness are described and a customized moment-based fitting procedure of MMPP to traffic traces is presented. Our methodology of doing this is to examine whether the MMPP can be used to predict the performance of a queue to which MMPP sample paths and measured traffic traces are fed for comparison respectively, in addition to the goodness-of-fit test of MMPP. Numerical results and simulations show that the fitted MMPP can approximate multifractal traffic quite well, i.e. accurately predict the queueing performance.
基金Supported by grants from the National Natural Science Foundation of China(No.81071831)Jiangsu Provincial Health Bureau issues(No.H201021)+1 种基金Xuzhou City Science and Technology Bureau issues(No.XF10C082)Jiangsu Province Natural Science Foundation of China(No.BK20131131)
文摘Objective The aim of this study was to compare the long-term local control, overall survival, and late toxicities of positron emission tomography/computed tomography (PET/CT)-guided dose escalation radio- therapy versus conventional radiotherapy in the concurrent chemoradiotherapy treatment of locally ad- vanced nasopharyngeal carcinoma (NPC). Methods Atotal of 48 patients with stage IIl-IVa NPC were recruited and randomly administered PET/CT- guided dose escalation chemoradiotherapy (group A) or conventional chemoradiotherapy (group B). The dose-escalation radiotherapy was performed using the simultaneous modulated accelerated radiotherapy technique at prescribed doses of 77 gray (Gy) in 32 fractions (f) to the gross target volume (GTV): planning target volume (PTV) 1 received 64 Gy/32 f, while PTV2 received 54.4 Gy/32 f. Patients in group B received uniform-dose intensity-modulated radiotherapy, PTV1 received 70 Gy/35 f and PTV2 received 58 Gy/29 f. Concurrent chemotherapy consisted of cisplatin [20 mg/m2 intravenous (IV) on days 1-4] and docetaxel (75 mg/m2 IV on days 1 and 8) administered during treatment weeks 1 and 4. All patients received 2-4 cycles of adjuvant chemotherapy of the same dose and drug regimen. Results The use of fluorine-18-fluorodeoxyglucose (18F-FDG) PET/CT significantly reduced the treat- ment volume delineation of the GTV in 83.3% (20/24) of patients. The 5-year local recurrence-free survival rates of the two groups were 100% and 79.2%, respectively (P = 0.019). The 5-year disease free survival (DFS) rates were 95.8% and 75.0%, respectively (P = 0.018). The 5-year local progression-free survival and DFS rates were significantly different. The 5-year overall survival (OS) rates were 95.8% and 79.2%, re- spectively. Differences in OS improvement were insignificant (P = 0.079). Late toxicities were similar in the two groups. The most common late toxicities of the two arms were grade 1-2 skin dystrophy, xerostomia, subcutaneous fibrosis, and hearing loss. There were no cases of grade 4 late toxicity. Conclusion The use of 18F-FDG PET/CT-guided dose escalation radiotherapy is well tolerated and can reduce local recurrence rates for patients with locally advanced NPC compared to conventional chemora- diotherapy.
文摘Metal Fe/Pd compositionally modulated films(CMFs) were prepared by vapour depo- sition from two sources onto glass substrate under vacuum.The modulation and crystal structures of the films were examined by X-ray diffraction.The magnetic properties were determined by vibrating sample magnetometer.The Pd layers in the Fe/Pd CMFs are of fcc structure,and the Fe layer structure transits from bcc into amorphous,state with decreasing thickness of Fe layer.The dependence of specific saturation magnetization on thickness of Fe layers has also been discussed.
文摘OBJECTIVE To evaluate the clinical efficacy and toxicities of simultaneous modulated accelerated radiotherapy (SMART) and concurrent chemotherapy for locally advanced nasopharyngeal carcinoma. METHODS Eightyseven patients with nasopharyngeal carcinoma received SMART from April 2002 to September 2006. According to the UICC staging system, 30 patients were diagnosed as stage IIb, 42 patients stage III, 13 patients stage IVa and 2 patients stage IVb. The intensitymodulated radiotherapy was delivered with the "step and shoot" SMART technique with the prescribed dose of 66-76 Gy (2.2-2.4 Gy/day) to the gross tumor volume (GTV) and positive neck lymph nodes (GTVLN), with 60 Gy (2.0 Gy/day) to the highrisk clinical target volume (CTV1), encompassing the area around the nasopharynx and the upper neck, and with 54 Gy (1.8 Gy/day) to the lowrisk clinical target volume (CTV2), including the lower neck and supraclavicular area. Among all the patients, 31 received 2 cycles of SMART concurrently with 5 fluorouracil (5-Fu) and cisplatin (the FP group) and 56 received 2 cycles of concurrent cisplatin. All the patients received 3 to 4 cycles of adjuvant combination chemotherapy of cisplatin and 5fluorouracil starting from the 1st month after completion of SMART. RESULTS With a median follow up of 59 months (ranging from 19 to 85 months), the 1, 2 and 3year overall survival rates were 100%, 94.6% and 91.3% respectively. Acute mucositis and pharyngitis were more frequently observed in the FP group than in the cisplatin group. CONCLUSION SMART technique provides an excellent opportunity to spare normal tissue and is probably more biologically effective. Combination of single cisplatin was more tolerable.
基金Supported by The National Natural Science Foundation of China, No. 30870738
文摘AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC were selected, including 5 cases located in the cervical, the upper, the middle and the lower thorax, respectively. Five plans were generated with the eclipse planning sys- tem: three using c-IMRT with 5 fields (5F), 7 fields (7F) and 9 fields (gF), and two using VMAT with a single arc (1A) and double arcs (2A). The treatment plans were designed to deliver a dose of 60 Gy to the plan-ning target volume (PTV) with the same constrains in a 2.0 Gy daily fraction, 5 d a week. Plans were normal- ized to 95% of the PTV that received 100% of the pre- scribed dose. We examined the dose-volume histogram parameters of PTV and the organs at risk (OAR) such as lungs, spinal cord and heart. Monitor units (MU) and normal tissue complication probability (NTCP) of OAR were also reported. RESULTS: Both c-IMRT and VMAT plans resulted in abundant dose coverage of PTV for EC of different Io- cations. The dose conformity to PTV was improved as the number of field in c-IMRT or rotating arc in VMAT was increased. The doses to PTV and OAR in VMAT plans were not statistically different in comparison with c-IMRT plans, with the following exceptions: in cervical and upper thoracic EC, the conformity index (CI) was higher in VMAT (1A 0.78 and 2A 0.8) than in c-IMRT (5F 0.62, 7F 0.66 and 9F 0.73) and homogeneity was slightly better in c-IMRT (7F 1.09 and 9F 1.07) than in VMAT (1A 1,1 and 2A 1.09), Lung V30 was lower in VMAT (1A 12.52 and 2A 12.29) than in c-IMRT (7F 14.35 and 9F 14.81). The humeral head doses were significantly increased in VMAT as against c-IMRT. In the middle and lower thoracic EC, CI in VMAT (1A 0.76 and 2A 0.74) was higher than in c-IMRT (5F 0.63 Gy and 7F 0.67 Gy), and homogeneity was almost similar between VMAT and c-IMRT. V20 (2A 21.49 Gy vs 7F 24.59 Gy and 9F 24.16 Gy) and V30 (2A 9.73 Gy vs 5F 12.61 Gy, 7F 11.5 Gy and 9F 11.37 Gy) of lungs in VMAT were lower than in c-IMRT, but low doses to lungs (V5 and Vl0) were increased. V30 (1A 48.12 Gy vs 5F 59.2 Gy, 7F 58.59 Gy and 9F 57.2 Gy), V40 and V50 of heart in VMAT was lower than in c-IMRT. MUs in VMAT plans were significantly reduced in comparison with c-IMRT, maximum doses to the spinal cord and mean doses of lungs were similar between the two techniques. NTCP of spinal cord was 0 for all cases. NTCP of lungs and heart in VMAT were lower than in c-IMRT. The advantage of VMAT plan was enhanced by doubling the arc. CONCLUSION: Compared with c-IMRT, VMAT, especial- ly the 2A, slightly improves the OAR dose sparing, such as lungs and heart, and reduces NTCP and MU with a better PTV coverage.