The hot spot temperature of a transformer is one of the critical indicators reflecting its operating status.Accurate and fast calculation of hot spot temperature is significant for the online monitoring of transformer...The hot spot temperature of a transformer is one of the critical indicators reflecting its operating status.Accurate and fast calculation of hot spot temperature is significant for the online monitoring of transformers.Considering the low computational efficiency of the transformer’s numerical full model(FM),this paper presents a model simplification method based on the equivalent thermal parameters of windings to expedite hot spot temperature computation.Initially,the representative volume element(RVE)reflecting the periodic structure of windings is selected to formulate a reduced model(RM)for the transformer.Subsequently,to achieve equivalence between the RM and the FM,the equivalent thermal parameters of the RVE are calculated,containing the equivalent thermal conductivity(ETC),the equivalent density(ED),and the equivalent specific heat capacity(ESHC).Finally,the validity of the RM is verified by the temperature rise test.The results show that,compared with the tested data,the maximum error of the hot spot temperature calculated by the RM is 2.56 K,demonstrating the accuracy of the hot spot temperature calculation by the RM.Compared with the FM,the computing time of the proposed RM is reduced to 1/189,which significantly improves the computational efficiency.展开更多
基金supported by Hubei Technology Innovation Center for Smart Hydropower(SDCXZX-JJ-2023-03).
文摘The hot spot temperature of a transformer is one of the critical indicators reflecting its operating status.Accurate and fast calculation of hot spot temperature is significant for the online monitoring of transformers.Considering the low computational efficiency of the transformer’s numerical full model(FM),this paper presents a model simplification method based on the equivalent thermal parameters of windings to expedite hot spot temperature computation.Initially,the representative volume element(RVE)reflecting the periodic structure of windings is selected to formulate a reduced model(RM)for the transformer.Subsequently,to achieve equivalence between the RM and the FM,the equivalent thermal parameters of the RVE are calculated,containing the equivalent thermal conductivity(ETC),the equivalent density(ED),and the equivalent specific heat capacity(ESHC).Finally,the validity of the RM is verified by the temperature rise test.The results show that,compared with the tested data,the maximum error of the hot spot temperature calculated by the RM is 2.56 K,demonstrating the accuracy of the hot spot temperature calculation by the RM.Compared with the FM,the computing time of the proposed RM is reduced to 1/189,which significantly improves the computational efficiency.