期刊文献+
共找到2,881篇文章
< 1 2 145 >
每页显示 20 50 100
Data-Driven Component-Level Decision-Making for Online Remanufacturing of Gas-Insulated Switchgear
1
作者 Hansam Cho Seokho Moon +2 位作者 Sunhyeok Hwang Seoung Bum Kim Younghoon Kim 《Computer Modeling in Engineering & Sciences》 2025年第11期1941-1967,共27页
Accurately determining when and what to remanufacture is essential for maximizing the lifecycle value of industrial equipment.However,existing approaches face three significant limitations:(1)reliance on predefined ma... Accurately determining when and what to remanufacture is essential for maximizing the lifecycle value of industrial equipment.However,existing approaches face three significant limitations:(1)reliance on predefined mathematical models that often fail to capture equipment-specific degradation,(2)offline optimization methods that assume access to future data,and(3)the absence of component-level guidance.To address these challenges,we propose a data-driven framework for component-level decision-making.The framework leverages streaming sensor data to predict the remaining useful life(RUL)without relying on mathematical models,employs an online optimization algorithm suitable for practical settings,and,through remanufacturing simulations,provides guidance on which components should be replaced.In a case study on gas-insulated switchgear,the proposed framework achieved RUL prediction performance comparable to an oracle model in an online setting without relying on predefined mathematical models.Furthermore,by employing online optimization,it determined a remanufacturing timing close to the global optimum using only past and current data.In addition,unlike previous studies,the framework enables component-level decision-making,allowing for more detailed and actionable remanufacturing guidance in practical applications. 展开更多
关键词 REMANUFACTURING online decision-making gas-insulated switchgear online learning
在线阅读 下载PDF
Discharge fault detection of dry air switchgear based on ZnO-MoS_(2) gas
2
作者 Peng LI Ye YUAN +4 位作者 Rong ZHOU Lin LI Hao CUI Ziheng PU Xuelin YANG 《Plasma Science and Technology》 2025年第4期12-21,共10页
When discharge faults occur in dry air switchgear,the air decomposes to produce diverse gases,with NO_(2) reaching the highest levels.Detecting the NO_(2) level can reflect the operation status of the equipment.This p... When discharge faults occur in dry air switchgear,the air decomposes to produce diverse gases,with NO_(2) reaching the highest levels.Detecting the NO_(2) level can reflect the operation status of the equipment.This paper proposes to combine ZnO cluster with MoS_(2) to improve the gassensitive properties of the monolayer.Based on the Density Functional Theory(DFT),the effect of(ZnO)n size on the behavior of MoS_(2 )is considered.Key parameters such as adsorption energy and band gap of(ZnO)n-MoS_(2)/NO_(2) system were calculated.The ZnO-MoS_(2) heterojunction was successfully synthesized by a hydrothermal method.The gas sensor exhibits a remarkable response and a fast response-recovery time to 100 ppm NO_(2).In addition,it demonstrates excellent selectivity,long-term stability and a low detection limit.This work confirms the potential of the ZnO-MoS_(2) composite structure as a highly effective gas sensor for NO_(2) detection,which provides valuable theoretical and experimental insights for fault detection in dry air switchgear. 展开更多
关键词 dry air switchgear discharge fault DFT ZnO-MoS_(2) gas sensing mechanism(Some figures may appear in colour only in the online journal)
在线阅读 下载PDF
A Novel Modularizing Design Method of 10 kV High Voltage Switchgear for Live Maintenance 被引量:2
3
作者 Yuan Yao Xudong Ouyang +2 位作者 Guowei Zeng Qi Tang Wenyu Ma 《Energy and Power Engineering》 2020年第4期1-13,共13页
Due to imperfect manufacturing technology, design defects and environmental impact, the failure rate of 10 kV switchgear is very high. For this reason, based on taken present situation of traditional switchgear and th... Due to imperfect manufacturing technology, design defects and environmental impact, the failure rate of 10 kV switchgear is very high. For this reason, based on taken present situation of traditional switchgear and the current technical requirements for switchgear into account, a new reliable and safe modular high voltage switchgear design method is presented in this paper, which can reduce the failure rate of switchgear and improve the reliability of power supply. The electric field and temperature rise simulation model are established to check the reasonability and validity. By using the finite element software, the simulation results show that the design in this paper has a maximum temperature rise of 55 K for the main cabinet and a maximum temperature rise of 45 K for the deputy cabinet, which is far below the international standard of 70 K. The areas where the partial discharge is likely to occur within the switchgear are places such as the connection between bus-bar and cabinet, bus-bar joint and bus-bar corner. In order to avoid potential dangers, the discharge point must be located in time to prevent insulation fault of electrical equipment of the high voltage switchgear. The simulation results demonstrate that the design method in this paper greatly improve the reliability of switchgear and meets the demands of power system. 展开更多
关键词 switchgear FINITE ELEMENT Temperature FIELD ELECTRIC FIELD Improvement
在线阅读 下载PDF
Statistical characteristics of transient enclosure voltage in ultra-high-voltage gas-insulated switchgear 被引量:2
4
作者 Yuanji CAI Yonggang GUAN Weidong LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第6期74-81,共8页
Transient enclosure voltage(TEV),which is a phenomenon induced by the inner dielectric breakdown of SF_6 during disconnector operations in a gas-insulated switchgear(GIS),may cause issues relating to shock hazard ... Transient enclosure voltage(TEV),which is a phenomenon induced by the inner dielectric breakdown of SF_6 during disconnector operations in a gas-insulated switchgear(GIS),may cause issues relating to shock hazard and electromagnetic interference to secondary equipment.This is a critical factor regarding the electromagnetic compatibility of ultra-high-voltage(UHV)substations.In this paper,the statistical characteristics of TEV at UHV level are collected from field experiments,and are analyzed and compared to those from a repeated strike process.The TEV waveforms during disconnector operations are recorded by a self-developed measurement system first.Then,statistical characteristics,such as the pulse number,duration of pulses,frequency components,magnitude and single pulse duration,are extracted.The transmission line theory is introduced to analyze the TEV and is validated by the experimental results.Finally,the relationship between the TEV and the repeated strike process is analyzed.This proves that the pulse voltage of the TEV is proportional to the corresponding breakdown voltage.The results contribute to the definition of the standard testing waveform of the TEV,and can aid the protection of electronic devices in substations by minimizing the threat of this phenomenon. 展开更多
关键词 transient enclosure voltage (TEV) gas-insulated switchgear (GIS) ultra-high-voltage (UHV) repeated strike process DISCONNECTOR
在线阅读 下载PDF
THE STUDY ON MEASURING TECHNIQUE OF PARTIAL DISCHARGE IN GAS INSULATED SWITCHGEAR USING ULTRA HIGH FREQUENCY METHOD WITH EXTERNAL SENSORS 被引量:1
5
作者 李忠 冯允平 《Journal of Pharmaceutical Analysis》 SCIE CAS 2005年第2期7-10,15,共5页
Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this ... Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique. 展开更多
关键词 gas insulated switchgear partial discharge ultra high frequency finite-difference time-domain (FDTD) method MEASUREMENT external sensor
在线阅读 下载PDF
Denoising Method for Partial Discharge Signal of Switchgear Based on Continuous Adaptive Wavelet Threshold 被引量:1
6
作者 Zhuo Wang Xiang Zheng Tiantian Liang 《Journal of Harbin Institute of Technology(New Series)》 CAS 2022年第4期7-18,共12页
Partial discharge(PD)is an important reason for the insulation failure of the switchgear.In the process of PD detection,PD signal is often annihilated in strong noise.In order to improve the accuracy of PD detection i... Partial discharge(PD)is an important reason for the insulation failure of the switchgear.In the process of PD detection,PD signal is often annihilated in strong noise.In order to improve the accuracy of PD detection in power plant switchgear,a method based on continuous adaptive wavelet threshold switchgear PD signals denoising is proposed in this paper.By constructing a continuous adaptive threshold function and introducing adjustment parameters,the problems of over⁃processing of traditional hard threshold functions and incomplete denoising of soft threshold functions can be improved.The analysis results of simulated signals and measured signals show that the continuous adaptive wavelet threshold denoising method is significantly better than the traditional denoising method for the PD signal.The proposed method in this paper retains the characteristics of the original signal.Compared with the traditional denoising methods,after denoising the simulated signals,the signal⁃to⁃noise ratio(SNR)is increased by more than 30%,and the root⁃mean⁃square error(RMSE)is reduced by more than 30%.After denoising the real signal,the noise suppression ratio(NRR)is increased by more than 40%.The recognition accuracy rate of PD signal has also been improved to a certain extent,which proves that the method has a certain practicability. 展开更多
关键词 switchgear partial discharge wavelet threshold function DENOISING
在线阅读 下载PDF
Automatic wiring method for switchgear design 被引量:1
7
作者 Shi Kanle Gao Ying +2 位作者 Wu Zijian Zhang Hui Yong Junhai 《Computer Aided Drafting,Design and Manufacturing》 2017年第2期32-38,共7页
An automatic 3D wiring method for switchgear design is proposed in this paper. First, wiring constraints are created, and a corresponding evaluation model is proposed. Then, based on the structure of the cabinet, we p... An automatic 3D wiring method for switchgear design is proposed in this paper. First, wiring constraints are created, and a corresponding evaluation model is proposed. Then, based on the structure of the cabinet, we propose a contour expansion scheme to construct rough paths. Different wiring features of the switchgear are used to connect rough local paths. All the paths are represented in a uniform data structure and forma path network. Finally, an improved A* algorithm is used to search the wiring path between the components in the routing network; the evaluation model is considered as heuristic rules for path searching. The result can satisfy the practical requirements of switchgear design. Experimental results are also provided. 展开更多
关键词 wiring method path searching contour expansion switchgear design A* algorithm
在线阅读 下载PDF
A Wireless Solution for Train Switchgear Contact Temperature Monitoring and Alarming System Based on Wireless Communication Technology
8
作者 Lexiang Wei Xiaoqing Zeng, Tuo Shen 《International Journal of Communications, Network and System Sciences》 2015年第4期79-84,共6页
We present a temperature monitoring and warning system, which is based on wireless communi- cation technology and applied in train switchgear in this paper. The system is consists of three parts, including wireless te... We present a temperature monitoring and warning system, which is based on wireless communi- cation technology and applied in train switchgear in this paper. The system is consists of three parts, including wireless temperature detection module, inter-vehicle transmission networks module and?remote monitoring server. The switchgear contact temperature data are collected via the wireless temperature detection module and exchanged in inter-vehicle wireless networking by Zigbee modules. Then the temperature of train switchgear cabinets can be monitored remotely through the GPRS wireless communication. 展开更多
关键词 TRAIN switchgear WIRELESS TEMPERATURE Monitoring COMMUNICATION Technology
在线阅读 下载PDF
Design of Distributed Temperature Measurement System for Switchgear
9
作者 Qingsong Yang Jianfei Yang +1 位作者 Huaren Wu Long Liu 《Energy and Power Engineering》 2013年第4期958-961,共4页
This paper develops a novel distributed temperature measurement system based on DSP and DS18B20 digital thermometer. The real-time temperature of each node in the switchgear is obtained by several DS18B20s which are c... This paper develops a novel distributed temperature measurement system based on DSP and DS18B20 digital thermometer. The real-time temperature of each node in the switchgear is obtained by several DS18B20s which are connected on the 1-wire bus together. RS-485 master-slave communication protocol is used to centralize monitoring temperatures of several switchgear cabinets. The system also has the function of temperature alarm. The operation of simulation experiment has showed that the system is able to complete monitoring real-time temperatures in high voltage switchgear. 展开更多
关键词 High Voltage switchgear DISTRIBUTED Temperature Measurement 1-WIRE BUS RS-485 MASTER-SLAVE Communication
在线阅读 下载PDF
A New Approach To Inspect the Internal Pressure of Vacuum Switchgear
10
作者 罗利文 赵子玉 李海玉 《Journal of Shanghai Jiaotong university(Science)》 EI 2008年第4期473-476,共4页
A new approach is developed to inspect the internal pressure within the vacuum switchgear by no means of magnet-exciting coil, micro-discharge threshold voltage Ud and field emission threshold voltage Ud all of which ... A new approach is developed to inspect the internal pressure within the vacuum switchgear by no means of magnet-exciting coil, micro-discharge threshold voltage Ud and field emission threshold voltage Ud all of which are available in laboratory. Experimental results show that internal pressure is a function of the ratio of the micro-discharge threshold voltage to the field emission threshold voltage i.e., Ud/Ue. By this method, the internal pressure in the range of 10^0-10^-4 Pa within vacuum chambers can be inspected without magnet-exciting coil which is required in conventional magnetron discharge method. 展开更多
关键词 vacuum switchgear internal pressure MICRO-DISCHARGE field emission
原文传递
Shanghai Hua Tong Switchgear Works -A Major Switchgear Manufacturer for Power Transmission, Substation and Distribution in China
11
作者 Shao LingHua Tong Switchgear Works 《Electricity》 1996年第1期35-37,共3页
Founded in 1919, Shanghai Hua Tong Switchgear Works ("HTSW" in short for below) is one of large enterprises on state level. With high and new technology, it is designed as an export base for mechanical and e... Founded in 1919, Shanghai Hua Tong Switchgear Works ("HTSW" in short for below) is one of large enterprises on state level. With high and new technology, it is designed as an export base for mechanical and electrical product of the Ministry of Machinery Industry as well. It has been awarded the honor of first grade factory in the competition for key and major project construction in Shanghai year by year, 展开更多
关键词 A Major switchgear Manufacturer for Power Transmission Shanghai Hua Tong switchgear Works Substation and Distribution in China
在线阅读 下载PDF
Tender for 500 kV transformers and switchgears forThree Gorges Project is ready
12
《Electricity》 1998年第2期46-46,共1页
关键词 PROJECT Tender for 500 kV transformers and switchgears for KV
在线阅读 下载PDF
Partial Discharge Detection and Fault Diagnosis of Switchgear Based on Ultra High Frequency
13
作者 XIEYinzhi GAOJinru 《外文科技期刊数据库(文摘版)工程技术》 2022年第4期165-169,共5页
In view of the switch partial discharge detection work, ultra-high frequency is undoubtedly the best detection method among many detection methods. The detection method has the characteristics of high sensitivity and ... In view of the switch partial discharge detection work, ultra-high frequency is undoubtedly the best detection method among many detection methods. The detection method has the characteristics of high sensitivity and strong anti-interference. Aiming at several kinds of problems that often occur in switch cabinets, after scientific design, four partial discharge models including sharp point, sharp plate, air gap and edge surface are made, and an ultra-high frequency partial discharge detection platform is built here. Aiming at the work of parameter extraction, it is usually carried out by using the traditional statistical method, and then the fault problems are analyzed through the PSO-SVM algorithm. At the same time, it is also necessary to concatenate the statistical and video domain feature vectors, and then carry out the data extraction work. Finally, it is carrying out the comparison work with the BP neural network fault diagnosis algorithm. According to the results after comparison, PSO-SVM algorithm has better recognition rate, which can reach 98.5% at most. It provides a good reference value for future work. 展开更多
关键词 local discharge UHF switchgear
原文传递
Summary of Research on Thermal Mechanical Effect of Internal Short Circuit Arcing in Medium Voltage Switchgear
14
作者 TIAN Yunxia 《外文科技期刊数据库(文摘版)工程技术》 2021年第10期1181-1184,共6页
Medium voltage switchgear is widely used in distribution network. It plays the role of power distribution, measurement, control and protection circuit in residents, factories and public service facilities. However, du... Medium voltage switchgear is widely used in distribution network. It plays the role of power distribution, measurement, control and protection circuit in residents, factories and public service facilities. However, due to the high standard and complexity of the structural design of the medium voltage switchgear, some product defects will lead to a certain short circuit fault of the medium voltage switchgear. This paper analyzes the short-circuit fault of medium voltage switchgear, introduces the research on arc extinguishing technology of medium voltage switchgear, and puts forward corresponding preventive countermeasures, which is helpful to reduce the short-circuit fault of medium voltage switchgear in power grid. 展开更多
关键词 medium voltage switchgear short circuit fault preventive measure
原文传递
Solutions to Consider in Current Transformer Selection for APR1400 Nuclear Power Plant Medium Voltage Switchgears
15
作者 Dumam Roman Jackson Choong-Koo Chang 《Journal of Energy and Power Engineering》 2017年第10期670-678,共9页
This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medi... This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medium voltage switchgear of a nuclear power plant. This consideration is important for both measurement and protection functions of the digital protective relays. This is a study to ascertain the best options for a suitable solution to prevent CT saturation in relations to its protective capabilities during short circuit fault without compromising the CT accuracy class during normal operation of the system, while ensuring its conformity to the design requirement is within limit. The advantages of current transformers have proven not only to be reliable and safe, but also are of easy handling, reduction of the cost and components on the MV (medium voltage) switchgear. The purpose of this research is to identify best approach to resolve the existing problems in the current protection system. With the view of LPCT (low power current transformer) which has been newly constructed by few manufacturers to provide good protection and a wide range of measuring function without errors, some other solutions will be considered in this research. 展开更多
关键词 CT CT saturation accuracy class metering CT protection CT MV switchgear short circuit fault current knee voltage.
在线阅读 下载PDF
面向数字孪生应用的大容量GIS整间隔稳态温升及降阶模型研究 被引量:1
16
作者 侯世英 罗澳 +3 位作者 杨帆 权帅峰 霍小晶 孙帅 《高电压技术》 北大核心 2025年第5期2300-2310,共11页
超高压、大容量、数字化电网目标架构对高压开关领域提出了新的挑战。为研究550 kV/8 000 A气体绝缘开关设备(gas insulated switchgear,GIS)的稳态温升,解决获取温度场时存在模型自由度大、计算时间长等问题,该文研究了GIS整间隔模型... 超高压、大容量、数字化电网目标架构对高压开关领域提出了新的挑战。为研究550 kV/8 000 A气体绝缘开关设备(gas insulated switchgear,GIS)的稳态温升,解决获取温度场时存在模型自由度大、计算时间长等问题,该文研究了GIS整间隔模型热特性并构建了基于本征正交分解(proper orthogonal decomposition,POD)方法的温度场降阶模型以面向数字孪生应用。首先,建立了基于物联网的电力设备数字孪生实现架构,提出了数字孪生驱动的GIS状态感知方法框架。基于该框架,搭建了以珠东北站示范工程中的GIS为原型的虚拟实体模型,分析了模型在8 800 A时的磁密、损耗、温度以及气流流速分布,进而搭建了大电流温升试验平台进行验证,试验测量结果与仿真结果吻合度高。其次,采用拉丁超立方采样方法构建该模型在不同工况下的快照矩阵输入参数样本集,进一步对温度快照采用POD方法生成温度场降阶模型。最后,对比了降阶前后模型的计算时长与误差:降阶模型相较全阶模型的计算时长由小时级降至秒级,阶数为6时均方根误差为0.053%满足POD误差规范要求。该文研究结果可为大容量开关的设计和运维提供支撑,为数字孪生技术在开关设备领域的应用提供参考。 展开更多
关键词 气体绝缘开关设备 数字孪生 多物理场仿真 降阶模型 本征正交分解
原文传递
基于传感器和蓝牙通信技术的高压开关柜智能感知终端设计 被引量:1
17
作者 郭大鹏 谷志强 +3 位作者 李巍 聂传波 班东坡 常辉 《黑龙江科学》 2025年第20期130-133,共4页
高压开关柜是电力系统中的重要设备,主要用于电能分配和监控。普通的高压开关柜设计制造较为成熟,但其智能化水平和智能感知能力较低,故提出一种基于传感器和蓝牙通信技术的高压开关柜智能感知终端,采用多路光电隔离电路对开关柜内高压... 高压开关柜是电力系统中的重要设备,主要用于电能分配和监控。普通的高压开关柜设计制造较为成熟,但其智能化水平和智能感知能力较低,故提出一种基于传感器和蓝牙通信技术的高压开关柜智能感知终端,采用多路光电隔离电路对开关柜内高压带电情况进行检测,采用温湿度传感器对温湿度进行监测,采用烟雾传感器对烟雾浓度进行监测,采用红外传感器对开关柜内是否有小动物入侵进行监测。智能感知终端可将传感器数据与蓝牙通信技术相融合,通过蓝牙通信方式与移动设备进行双向通信,集成开关柜门检测及控制、LED显示控制等多种功能。实验测试结果表明,智能感知终端可实现对高压开关柜的智能识别,实时监控和科学管理,可有效提升高压开关柜的安全性和智能化水平。 展开更多
关键词 高压开关柜 传感器 蓝牙通信
在线阅读 下载PDF
GIS本体与表计环境温差对SF_(6)密度测量影响的实验研究
18
作者 张磊 宋辉 +1 位作者 盛戈皞 江秀臣 《电机与控制学报》 北大核心 2025年第9期51-60,共10页
为了准确评估六氟化硫(SF_(6))气体密度测量中因环境与设备温差导致的误差问题,采用实验分析方法,设计了可模拟不同温差的SF_(6)气体密度检测平台。通过精确控温装置调节表计与环境温度,系统研究了温差对密度测量值的影响机制,并通过实... 为了准确评估六氟化硫(SF_(6))气体密度测量中因环境与设备温差导致的误差问题,采用实验分析方法,设计了可模拟不同温差的SF_(6)气体密度检测平台。通过精确控温装置调节表计与环境温度,系统研究了温差对密度测量值的影响机制,并通过实验数据分析发现,当表计温度低于设备温度时,所测密度值呈上升趋势,在0~10℃的温差范围内,误差比例最高可达3.23%;相反,若表计温度高于设备温度,密度测量值则下降,同等温差范围内误差比例达3.26%。在气压恒定的条件下,密度测量值与环境温度变化呈显著负相关,其与标准值的偏差与环境温差之间呈现高度线性关系。基于上述分析,提出一种基于时间序列数据的SF_(6)密度表自诊断方法,可用于识别因环境温度差异所引起的密度示数异常。该方法有助于提升对GIS设备真实状态的判断能力,为电力设备的安全稳定运行提供技术支持。 展开更多
关键词 SF_(6)密度 气体绝缘开关设备 自诊断 环境温度 温差 继电器
在线阅读 下载PDF
直流GIS/GIL金属异物运动特征、抑制及检测方法
19
作者 刘博 苏伟 +5 位作者 张泽皓 公多虎 杨闽 陈庚 何金良 李传扬 《高电压技术》 北大核心 2025年第3期1038-1051,共14页
直流气体绝缘金属封闭开关(gas-insulated metal enclosed switchgear,GIS)和输电线路(gas-insulated transmissionline,GIL)在制造、安装及运行过程不可避免引入金属异物,导致设备可靠性下降。研究金属异物运动特征,提出金属异物抑制... 直流气体绝缘金属封闭开关(gas-insulated metal enclosed switchgear,GIS)和输电线路(gas-insulated transmissionline,GIL)在制造、安装及运行过程不可避免引入金属异物,导致设备可靠性下降。研究金属异物运动特征,提出金属异物抑制及检测方法,对GIS/GIL设备高可靠运行意义重大。作者团队近5年聚焦直流GIS/GIL内部金属异物问题开展基础理论及技术研究,并在团队自研的±320 kV直流GIL及±550 kV直流GIS上对研究结论进行了验证,该文主要对作者团队研究内容及重要结论进行综述。首先,对金属异物溯源及运动特征进行了综述;其次,概述了团队在金属异物抑制策略方面的工作,并总结了基于光子计数的金属异物检测成果;最后,对下一步直流GIS/GIL金属异物亟待研究的方向及关键问题进行了探讨。 展开更多
关键词 直流气体绝缘组合电器 金属异物 运动特征 抑制策略 光子计数
原文传递
基于模糊神经网络的梅花触头电接触状态检测
20
作者 金立军 顾百丞 +3 位作者 姚思宇 张志伟 袁之康 张颖瑶 《仪表技术与传感器》 北大核心 2025年第10期113-118,共6页
为实现开关柜梅花触头电接触状态的准确评估,设计了基于模糊神经网络的状态检测系统。首先,提出了梅花触头电接触状态的检测方案和“感知层-数据层-模型层”的系统架构;其次,利用触头压紧力测试装置和回路电阻测试仪搭建检测系统,采集... 为实现开关柜梅花触头电接触状态的准确评估,设计了基于模糊神经网络的状态检测系统。首先,提出了梅花触头电接触状态的检测方案和“感知层-数据层-模型层”的系统架构;其次,利用触头压紧力测试装置和回路电阻测试仪搭建检测系统,采集触头压紧力和回路电阻数据,研究触头弹簧形变量和压紧力、回路电阻之间的关系;最后,采用模糊神经网络构建机电信息融合的故障诊断模型。结果表明检测系统能够有效评估梅花触头电接触状态,准确率高达92%,可为开关柜梅花触头的科学运维提供技术指导。 展开更多
关键词 开关柜 梅花触头 弹簧老化 状态评估 检测系统 模糊神经网络
在线阅读 下载PDF
上一页 1 2 145 下一页 到第
使用帮助 返回顶部