Sets of powerful microwave diagnostic systems have been developed on the HL-2 A tokamak,including 18 subsystems with high spatial and temporal resolutions.These systems have been applied in the HL-2 A tokamak experime...Sets of powerful microwave diagnostic systems have been developed on the HL-2 A tokamak,including 18 subsystems with high spatial and temporal resolutions.These systems have been applied in the HL-2 A tokamak experiments to investigate the core plasma transport,turbulence,MHD,energetic particle physics and so on.In this paper,the microwave diagnostics and their applications are reviewed.Some new technologies,including GHz sampling digital correlation electron cyclotron emission(DCECE),multi-channel correlation reflectometers,and solid state terahertz interferometers,are also presented in the paper.展开更多
This paper rerports a related microwave diagnostic methhod that measures both the electron number density and the electron-neu- tral collision frequency, which are crucial to understand the behavior of microwave trave...This paper rerports a related microwave diagnostic methhod that measures both the electron number density and the electron-neu- tral collision frequency, which are crucial to understand the behavior of microwave traveling in plasma. Arrays of standard commercial fluoresoent lamp placed directly against each other in two rows are used to produce a plasma layer. Attenuations of microwave by plasma layer are studied experimentally in the frequencies of 1--8 C44z using a synthesized signal generator and a spectnnn analyzer. Two wavepolarizations are trader investigation: dectric field of the wave is either parallel ( E -wave) or perpendicular (H-wave) to the fluorescent lamp axis. The electron number density and the electron-neutral collision frequency of fluorescent lamp plasma are obtained by microwave diagnostics, for the purpose of analyzing microwave scattering characteristics by plasma.展开更多
A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehen...A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehensive scanning system, we can realize not only automatic but also fast and accurate measurement, which will help to eliminate the effects of temperature drift and standing wave/multi-reflection. With the Matlab-based asymmetric two-dimensional Gaussian fitting method, all the desired parameters of the microwave beam can be obtained. This technique can be used in the design and testing of microwave diagnostic systems such as reflectometers and the electron cyclotron emission imaging diagnostic systems of the Experimental Advanced Superconducting Tokamak.展开更多
Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has bee...Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering.展开更多
The Doppler backscattering(DBS)diagnostic is widely used to measure the localized density fluctuations and the propagation velocity of turbulent structures.Microwave is launched at a frequency that approaches a cutoff...The Doppler backscattering(DBS)diagnostic is widely used to measure the localized density fluctuations and the propagation velocity of turbulent structures.Microwave is launched at a frequency that approaches a cutoff layer in the plasma at an angle oblique to the cutoff layer.A new Q-band multichannel DBS system based on a comb generator has been designed and tested for application on the HL-3 tokamak.With the comb generator and heterodyne scheme,the stability and flexibility of the new DBS system are improved.The new DBS diagnostic has a high output power(~10 dBm),good power flatness(<5 dB in Q-band),and frequency stability,and the inter-frequency separation is tunable remotely.This article introduces the system design,laboratory test results,and initial experimental results from the HL-3 tokamak.With the help of the newly developed multichannel DBS,the turbulence information can be studied with high temporal and spatial resolution.展开更多
A front-end optics system has been developed for the EAST microwave imaging reflectometry for 2D density fluctuation measurement.Via the transmitter optics system,a combination of eight transmitter beams with independ...A front-end optics system has been developed for the EAST microwave imaging reflectometry for 2D density fluctuation measurement.Via the transmitter optics system,a combination of eight transmitter beams with independent frequencies is employed to illuminate wide poloidal regions on eight distinct cutoff layers.The receiver optics collect the reflected wavefront and project them onto the vertical detector array with 12 antennas.Utilizing optimized Field Curvature adjustment lenses in the receiver optics,the front-end optics system provides a flexible and perfect matching between the image plane and a specified cutoff layer in the plasma,which ensures the correct data interpretation of density fluctuation measurement.展开更多
基金supported by the National Magnetic Confinement Fusion Science Program of China(Grant Nos.2014GB107001,2014GB108002,2013GB104000,2013GB-107002,2017YFE0301680 and 2017YFE0300500)Sichuan Science and Technology Program(Grant No.2018RZ0123)National Natural Science Foundation of China(Grant Nos.11475057,11705049,11705051,11775070,11305053 and 11261140326)
文摘Sets of powerful microwave diagnostic systems have been developed on the HL-2 A tokamak,including 18 subsystems with high spatial and temporal resolutions.These systems have been applied in the HL-2 A tokamak experiments to investigate the core plasma transport,turbulence,MHD,energetic particle physics and so on.In this paper,the microwave diagnostics and their applications are reviewed.Some new technologies,including GHz sampling digital correlation electron cyclotron emission(DCECE),multi-channel correlation reflectometers,and solid state terahertz interferometers,are also presented in the paper.
文摘This paper rerports a related microwave diagnostic methhod that measures both the electron number density and the electron-neu- tral collision frequency, which are crucial to understand the behavior of microwave traveling in plasma. Arrays of standard commercial fluoresoent lamp placed directly against each other in two rows are used to produce a plasma layer. Attenuations of microwave by plasma layer are studied experimentally in the frequencies of 1--8 C44z using a synthesized signal generator and a spectnnn analyzer. Two wavepolarizations are trader investigation: dectric field of the wave is either parallel ( E -wave) or perpendicular (H-wave) to the fluorescent lamp axis. The electron number density and the electron-neutral collision frequency of fluorescent lamp plasma are obtained by microwave diagnostics, for the purpose of analyzing microwave scattering characteristics by plasma.
基金supported by National Natural Science Foundation of China(Grant Nos.10990211,11475173)the ITER Domestic Program of China(Grant Nos.2013GB106002,2014GB109002)
文摘A new integrated technique for fast and accurate measurement of the quasi-optics, especially for the microwave/millimeter wave diagnostic systems of fusion plasma, has been developed. Using the LabVIEW-based comprehensive scanning system, we can realize not only automatic but also fast and accurate measurement, which will help to eliminate the effects of temperature drift and standing wave/multi-reflection. With the Matlab-based asymmetric two-dimensional Gaussian fitting method, all the desired parameters of the microwave beam can be obtained. This technique can be used in the design and testing of microwave diagnostic systems such as reflectometers and the electron cyclotron emission imaging diagnostic systems of the Experimental Advanced Superconducting Tokamak.
基金supported by the National Magnetic Confinement Fusion Energy Program of China(No.2019YFE03020001)the Collaborative Innovation Program of Hefei Science Center,CAS(No.2021HSC-CIP010)the Fundamental Research Funds for the Central Universities。
文摘Interpreting experimental diagnostics data in tokamaks,while considering non-ideal effects,is challenging due to the complexity of plasmas.To address this challenge,a general synthetic diagnostics(GSD)platform has been established that facilitates microwave imaging reflectometry and electron cyclotron emission imaging.This platform utilizes plasma profiles as input and incorporates the finite-difference time domain,ray tracing and the radiative transfer equation to calculate the propagation of plasma spontaneous radiation and the external electromagnetic field in plasmas.Benchmark tests for classical cases have been conducted to verify the accuracy of every core module in the GSD platform.Finally,2D imaging of a typical electron temperature distribution is reproduced by this platform and the results are consistent with the given real experimental data.This platform also has the potential to be extended to 3D electromagnetic field simulations and other microwave diagnostics such as cross-polarization scattering.
基金supported by National Natural Science Foundation of China(Nos.12105087,12275096,and 11922503)the Joint Funds of the National Natural Science Foundation of China(No.U21A20440)the Science and Technology Planning Project of Sichuan Province(No.2023YFG0139)。
文摘The Doppler backscattering(DBS)diagnostic is widely used to measure the localized density fluctuations and the propagation velocity of turbulent structures.Microwave is launched at a frequency that approaches a cutoff layer in the plasma at an angle oblique to the cutoff layer.A new Q-band multichannel DBS system based on a comb generator has been designed and tested for application on the HL-3 tokamak.With the comb generator and heterodyne scheme,the stability and flexibility of the new DBS system are improved.The new DBS diagnostic has a high output power(~10 dBm),good power flatness(<5 dB in Q-band),and frequency stability,and the inter-frequency separation is tunable remotely.This article introduces the system design,laboratory test results,and initial experimental results from the HL-3 tokamak.With the help of the newly developed multichannel DBS,the turbulence information can be studied with high temporal and spatial resolution.
基金supported by the National Magnetic Confinement Fusion Energy Program of China(Nos.2009GB107001 and 2014GB109002)
文摘A front-end optics system has been developed for the EAST microwave imaging reflectometry for 2D density fluctuation measurement.Via the transmitter optics system,a combination of eight transmitter beams with independent frequencies is employed to illuminate wide poloidal regions on eight distinct cutoff layers.The receiver optics collect the reflected wavefront and project them onto the vertical detector array with 12 antennas.Utilizing optimized Field Curvature adjustment lenses in the receiver optics,the front-end optics system provides a flexible and perfect matching between the image plane and a specified cutoff layer in the plasma,which ensures the correct data interpretation of density fluctuation measurement.