期刊文献+
共找到17,869篇文章
< 1 2 250 >
每页显示 20 50 100
Instantaneous desulfurization of molten steel with varied aluminum and silicon by CaO-Al_(2)O_(3) particles:In situ observation using confocal scanning laser microscopy
1
作者 Chunjie She Hejun Zhang +2 位作者 Yanhui Zhang Ying Ren Lifeng Zhang 《International Journal of Minerals,Metallurgy and Materials》 2026年第2期545-554,共10页
Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfur... Desulfurization of CaO–Al_(2)O_(3) particles in molten steel was observed in situ using high-temperature confocal scanning laser microscopy.The effects of the aluminum and silicon contents of molten steel on desulfurization were analyzed.When the total aluminum content in the steel increased from 6 to 1100 ppm,the CaS content in CaO–Al_(2)O_(3) particles increased from 2.1wt%to 84.84wt%after the reaction for 90 s.Furthermore,when the silicon content in the steel increased from 0.01wt%to 2.20wt%,the CaS content in CaO–Al_(2)O_(3) particles increased from 1.53wt%to 79.01wt%after the reaction for 90 s.This indicates that the increase in the aluminum and silicon contents of the steel promoted the desulfurization of CaO–Al_(2)O_(3) particles.A kinetic model was established to predict the CaO–Al_(2)O_(3) particles composition,and the diffusion coefficient of sulfur in CaO–Al_(2)O_(3) particles was 9.375×10^(−10)m^(2)·s^(−1) at 1600℃,which provided a new method for the calculation of diffusion coefficient. 展开更多
关键词 DESULFURIZATION high-temperature confocal scanning laser microscopy steel DESULFURIZER kinetic model ALUMINUM SILICON
在线阅读 下载PDF
Characteristics and differential diagnosis of common verrucous proliferative skin diseases under dermoscopy and reflectance confocal microscopy 被引量:1
2
作者 ZHOU Lu FU Yule +7 位作者 HUANG Jian TANG Zhen LU Jianyun TAN Lina WANG Dan ZENG Jinrong WANG Jia GAO Lihua 《中南大学学报(医学版)》 北大核心 2025年第3期358-365,共8页
Objective:Verrucous epidermal nevus(VEN),seborrheic keratosis(SK),verruca plana(VP),verruca vulgaris(VV),and nevus sebaceous(NS)are common verrucous proliferative skin diseases with similar clinical appearances,often ... Objective:Verrucous epidermal nevus(VEN),seborrheic keratosis(SK),verruca plana(VP),verruca vulgaris(VV),and nevus sebaceous(NS)are common verrucous proliferative skin diseases with similar clinical appearances,often posing diagnostic challenges.Dermoscopy and reflectance confocal microscopy(RCM)can aid in their differentiation,yet their specific features under these tools have not been systematically described.This study aims to summarize and analyze the dermoscopic and RCM features of VEN,SK,VP,VV,and NS.Methods:A total of 121 patients with histopathologically confirmed verrucous proliferative skin diseases were enrolled.Dermoscopy and RCM imaging was used to observe and analyze the microscopic features of these conditions.Results:Under dermoscopy,the 5 diseases displayed distinct characteristics:VEN typically showed gyriform structures;SK was characterized by gyriform structures,comedo-like openings,and milia-like cysts;VP and VV featured dotted vessels and frogspawn-like structures;NS presented as brownish-yellow globules.RCM revealed shared features such as hyperkeratosis and acanthosis across all 5 diseases.Specific features included gyriform structures and elongated rete ridges in VEN;pseudocysts and gyriform structures in SK;evenly distributed ring-like structures in VP;vacuolated cells and papillomatous proliferation in VV;and frogspawn-like structures in NS.Conclusion:These 5 verrucous proliferative skin conditions exhibit distinguishable features under both dermoscopy and RCM.The combination of these 2 noninvasive imaging modalities holds significant clinical value for the differential diagnosis of verrucous proliferative skin diseases. 展开更多
关键词 reflectance confocal microscopy DERMOSCOPY verrucous proliferation verrucous epidermal nevus seborrheic keratosis verruca plana verruca vulgaris nevus sebaceous
暂未订购
Application of high-temperature confocal scanning laser microscopy to investigate non-metallic inclusions in steel:a review
3
作者 N.Preisser Y.Wang +3 位作者 J.Cejka I.Gruber W.Mu S.K.Michelic 《Journal of Iron and Steel Research International》 2025年第2期334-352,共19页
High-temperature confocal scanning laser microscopy(HT-CSLM)is a potent methodology for investigating various phenomena in the field of metallurgy.Initially applied to the observation of solid phase transformations an... High-temperature confocal scanning laser microscopy(HT-CSLM)is a potent methodology for investigating various phenomena in the field of metallurgy.Initially applied to the observation of solid phase transformations and solidification,this method has gained traction in the field of non-metallic inclusion in steels in recent years.An overview of the experimental capabilities of HT-CSLM and the most important results of recent investigations regarding the topics of clean steel production are provided.It includes the formation of intragranular acicular ferrite(IAF)from the surface of non-metallic inclusions during the continuous cooling and heat treatment,which can be especially beneficial in the toughness of heat-affected zones of welded pieces.Furthermore,the investigation of agglomeration mechanisms of non-metallic inclusions(NMIs)in liquid steel is discussed to improve the insight into attraction forces between particles and clogging phenomena during continuous casting.Also,the dissolution of NMIs in various steelmaking slags can be observed by HT-CSLM to compare dissolution rates and mechanisms of NMI,where significant influences of temperature and chemical composition of the slag were shown.Last but not least,the experimental work regarding the interface between steel and slag is discussed,where novel techniques are currently being developed.A comprehensive summary of experimental techniques using HT-CSLM equipment to investigate different interactions of NMIs with steel and slag phases is compiled. 展开更多
关键词 Non-metallic inclusion STEEL High-temperature confocal scanning laser microscopy Interfacial phenomenon KINETICS
原文传递
Effect of CaO/SiO_(2)and CaO/Al_(2)O_(3)in CaO-Al_(2)O_(3)-SiO_(2)particles on desulfurization of molten steel studied by confocal scanning laser microscopy
4
作者 Chun-jie She Guo-jun Chen +1 位作者 Li-feng Zhang Ying Ren 《Journal of Iron and Steel Research International》 2025年第12期4207-4217,共11页
The instantaneous desulfurization of CaO-Al_(2)O_(3)-SiO_(2)slag particles in the molten steel was in situ observed using a high-temperature confocal scanning laser microscope.The desulfurization effect of CaO-Al_(2)O... The instantaneous desulfurization of CaO-Al_(2)O_(3)-SiO_(2)slag particles in the molten steel was in situ observed using a high-temperature confocal scanning laser microscope.The desulfurization effect of CaO-Al_(2)O_(3)-SiO_(2)slags with different compositions was discussed.The influence of CaO/Al_(2)O_(3)and CaO/SiO_(2)on the desulfurization effect was analyzed.It was shown that in the liquid phase range,the higher CaO/SiO_(2)and CaO/Al_(2)O_(3)can significantly improve the desulfurization effect of the slag.A dimensionless desulfurization index Sindex was introduced to evaluate the desulfurization ability of CaO-Al_(2)O_(3)-SiO_(2)slags quantitatively.The Sindex values of CaO-Al_(2)O_(3)-SiO_(2)with different compositions at 1550°C were calculated.It was suggested to use(65%-75%)CaO-(0-20%)SiO_(2)-(20%-40%)Al_(2)O_(3)slags to improve the molten steel desulfurization. 展开更多
关键词 DESULFURIZATION High-temperature confocal scanning laser microscopy Molten steel CaO-Al_(2)O_(3)-SiO_(2)particle
原文传递
In-situ observation of nonmetallic inclusions in steel using confocal scanning laser microscopy:A review 被引量:4
5
作者 Ying Ren Lifeng Zhang 《International Journal of Minerals,Metallurgy and Materials》 2025年第5期975-991,共17页
The characteristics of nonmetallic inclusions formed during steel production have a significant influence on steel performance.In this paper,studies on inclusions using confocal scanning laser microscopy(CSLM)are revi... The characteristics of nonmetallic inclusions formed during steel production have a significant influence on steel performance.In this paper,studies on inclusions using confocal scanning laser microscopy(CSLM)are reviewed and summarized,particularly the col-lision of various inclusions,dissolution of inclusions in liquid slag,and reactions between inclusions and steel.Solid inclusions exhibited a high collision tendency,whereas pure liquid inclusions exhibited minimal collisions because of the small attraction force induced by their<90°contact angle with molten steel.The collision of complex inclusions in molten steel was not included in the scope of this study and should be evaluated in future studies.Higher CaO/Al_(2)O_(3)and CaO/SiO_(2)ratios in liquid slag promoted the dissolution of Al_(2)O_(3)-based in-clusions.The formation of solid phases in the slag should be prevented to improve dissolution of inclusions.To accurately simulate the dissolution of inclusions in liquid slag,in-situ observation of the dissolution of inclusions at the steel-slag interface is necessary.Using a combination of CSLM and scanning electron microscopy-energy dispersive spectroscopy,the composition and morphological evolution of the inclusions during their modification by the dissolved elements in steel were observed and analyzed.Although the in-situ observa-tion of MnS and TiN precipitations has been widely studied,the in-situ observation of the evolution of oxide inclusions in steel during so-lidification and heating processes has rarely been reported.The effects of temperature,heating and cooling rates,and inclusion character-istics on the formation of acicular ferrites(AFs)have been widely studied.At a cooling rate of 3-5 K/s,the order of AF growth rate in-duced by different inclusions,as reported in literature,is Ti-O<Ti-Ca-Zr-Al-O<Mg-O<Ti-Zr-Al-O<Mn-Ti-Al-O<Ti-Al-O<Zr-Ti-Al-O.Further comprehensive experiments are required to investigate the quantitative relationship between the formation of AFs and inclusions. 展开更多
关键词 INCLUSION STEEL in-situ observation confocal scanning laser microscopy
在线阅读 下载PDF
In-situ observation and analysis of high temperature behavior of carbides in GCr15 bearing steel by confocal laser scanning microscopy 被引量:2
6
作者 Jun Ren Yue Teng +4 位作者 Xiang Liu Xi Xu Hui-gai Li Ke Han Qi-jie Zhai 《Journal of Iron and Steel Research International》 2025年第2期409-417,共9页
The high-temperature dissolution behavior of primary carbides in samples taken from GCr15 continuous-casting bloom was observed in-situ by confocal laser scanning microscopy.Equations were fitted to the dissolution ki... The high-temperature dissolution behavior of primary carbides in samples taken from GCr15 continuous-casting bloom was observed in-situ by confocal laser scanning microscopy.Equations were fitted to the dissolution kinetics of primary carbides during either heating or soaking.Dissolution of carbides proceeded in three stages(fast→slow→faster)as either temperature or holding time was increased.During the heating process and during the first and third stages of the soaking process,the original size of the carbides determined the steepness of the slope,but during the middle(“slow”)stage of the soaking process,the slope remained zero.The initial size of the carbides varied greatly,but their final dissolution temperature fell within the narrow range of 1210-1235℃,and the holding time remained within 50 min.Fractal analysis was used to study the morphological characteristics of small and medium-sized carbides during the dissolution process.According to changes in the fractal dimension before and after soaking,the carbides tended to evolve towards a more regular morphology. 展开更多
关键词 Bearing steel High-temperature confocal laser scanning microscope In-situ observation Primary carbide Fractal analysis
原文传递
Application of artificial intelligence-assisted confocal laser endomicroscopy in gastrointestinal imaging analysis
7
作者 Yu-Shun Liu Ze-Hua Shi +2 位作者 Yan-Rui Jin Cui-Ping Yang Cheng-Liang Liu 《Artificial Intelligence in Medical Imaging》 2025年第1期4-12,共9页
Confocal laser endomicroscopy(CLE)has become an indispensable tool in the diagnosis and detection of gastrointestinal(GI)diseases due to its high-resolution and high-contrast imaging capabilities.However,the early-sta... Confocal laser endomicroscopy(CLE)has become an indispensable tool in the diagnosis and detection of gastrointestinal(GI)diseases due to its high-resolution and high-contrast imaging capabilities.However,the early-stage imaging changes of gastrointestinal disorders are often subtle,and traditional medical image analysis methods rely heavily on manual interpretation,which is time-consuming,subject to observer variability,and inefficient for accurate lesion identification across large-scale image datasets.With the introduction of artificial intelligence(AI)technologies,AI-driven CLE image analysis systems can automatically extract pathological features and have demonstrated significant clinical value in lesion recognition,classification diagnosis,and malignancy prediction of GI diseases.These systems greatly enhance diagnostic efficiency and early detection capabilities.This review summarizes the applications of AI-assisted CLE in GI diseases,analyzes the limitations of current technologies,and explores future research directions.It is expected that the deep integration of AI and confocal imaging technologies will provide strong support for precision diagnosis and personalized treatment in the field of gastrointestinal disorders. 展开更多
关键词 confocal laser endomicroscopy Artificial intelligence Gastrointestinal diseases Medical image analysis Early diagnosis
暂未订购
Revealing the F_actin Networks in Interphase Nuclei of Garlic Clove Cells by Confocal Fluorescence Microscopy 被引量:2
8
作者 王冬梅 王学臣 张伟成 《Acta Botanica Sinica》 CSCD 2000年第11期1167-1171,共5页
The interphase nuclei of parenchyma cells and epidermal cells of garlic ( Allium sativum L.) clove were labelled with rabbit anti_actin antibody and FITC_conjugated goat anti_rabbit IgG antibody. The authors observ... The interphase nuclei of parenchyma cells and epidermal cells of garlic ( Allium sativum L.) clove were labelled with rabbit anti_actin antibody and FITC_conjugated goat anti_rabbit IgG antibody. The authors observed results with fluorescence microscopy and confocal laser scanning microscopy. The nuclei showed prominent green_yellow fluorescence, indicating the presence of actin in the nuclei. Fluorescence examination with TRITC_phalloidin showed distinctive red fluorescence in the nuclei, indicating that F_actin is present in the nuclei. Confocal laser scanning microscopy indicated the presence of F_actin containing network structures in the nuclei, but the network structures were absent and the nuclei still showed red fluorescence when the cells were treated with cytochalasin D before fixation; the red fluorescence in the nuclei was hard to be observed when the cells were treated with unlabelled phalloidin before the cells were stained with TRITC_phalloidin. These results indicate that F_actin is in the nuclei and forms network structures in the nuclei of garlic cells. 展开更多
关键词 interphase nucleus F_actin TRITC_phalloidin cytochalasin D confocal laser scanning microscopy Allium sativum
在线阅读 下载PDF
In vivo subsurface morphological and functional cellular and subcellular imaging of the gastrointestinal tract with confocal mini-microscopy 被引量:6
9
作者 Martin Goetz Beena Memadathil +5 位作者 Stefan Biesterfeld Constantin Schneider Sebastian Gregor Peter R Galle Markus F Neurath Ralf Kiesslich 《World Journal of Gastroenterology》 SCIE CAS CSCD 2007年第15期2160-2165,共6页
AIM: To evaluate a newly developed hand-held confocal probe for in vivo microscopic imaging of the complete gastrointestinal tract in rodents. METHODS: A novel rigid confocal probe (diameter 7 mm) was designed wit... AIM: To evaluate a newly developed hand-held confocal probe for in vivo microscopic imaging of the complete gastrointestinal tract in rodents. METHODS: A novel rigid confocal probe (diameter 7 mm) was designed with optical features similar to the flexible endomicroscopy system for use in humans using a 488 nm single line laser for fluorophore excitation, Light emission was detected at 505 to 750 nm. The field of view was 475 μm × 475 μm. Optical slice thickness was 7 μm with a lateral resolution of 0.7 μm. Subsurface serial images at different depths (surface to 250 μm) were generated in real time at 1024 × 1024 pixels (0.8 frames/s) by placing the probe onto the tissue in gentle, stable contact. Tissue specimens were sampled for histopathological correlation.RESULTS: The esophagus, stomach, small and large intestine and meso, liver, pancreas and gall bladder were visualised in vivo at high resolution in n = 48 mice. Real time microscopic imaging with the confocal minimicroscopy probe was easy to achieve. The different staining protocols (fluorescein, acriflavine, FITC-labelled dextran and L. esculentum lectin) each highlighted specific aspects of the tissue, and in vivo imaging correlated excellently with conventional histology. In vivo blood flow monitoring added a functional quality to morphologic imaging.CONCLUSION: Confocal microscopy is feasible in vivo allowing the visualisation of the complete GI tract at high resolution even of subsurface tissue structures. The new confocal probe design evaluated in this study is compatible with laparoscopy and significantly expands the field of possible applications to intra-abdominal organs. It allows immediate testing of new in vivo staining and application options and therefore permits rapid transfer from animal studies to clinical use in patients. 展开更多
关键词 confocal microscopy in vivo imaging ENDOmicroscopy Fluorescence
暂未订购
Clinical impact of confocal laser endomicroscopy in the management of gastrointestinal lesions with an uncertain diagnosis 被引量:7
10
作者 Carlos Robles-Medranda Maria Vargas +6 位作者 Jesenia Ospina Miguel Puga-Tejada Manuel Valero Miguel Soria Gladys Bravo Carlos Robles-Jara Hannah Pitanga Lukashok 《World Journal of Gastrointestinal Endoscopy》 CAS 2017年第8期389-395,共7页
To evaluate the clinical impact of confocal laser endomicroscopy (CLE) in the diagnosis and management of patients with an uncertain diagnosis. METHODSA retrospective chart review was performed. Patients who underwent... To evaluate the clinical impact of confocal laser endomicroscopy (CLE) in the diagnosis and management of patients with an uncertain diagnosis. METHODSA retrospective chart review was performed. Patients who underwent CLE between November 2013 and October 2015 and exhibited a poor correlation between endoscopic and histological findings were included. Baseline characteristics, indications, previous diagnostic studies, findings at the time of CLE, clinical management and histological results were analyzed. Interventions based on CLE findings were also analyzed. We compared the diagnostic accuracy of CLE and target biopsies of surgical specimens. RESULTSA total of 144 patients were included. Of these, 51% (74/144) were female. The mean age was 51 years old. In all, 41/144 (28.4%) lesions were neoplastic (13 bile duct, 10 gastric, 8 esophageal, 6 colonic, 1 duodenal, 1 rectal, 1 ampulloma and 1 pancreatic). The sensitivity, specificity, positive predictive value, negative predictive value, and observed agreement when CLE was used to detect N-lesions were 85.37%, 87.38%, 72.92%, 93.75% and 86.81%, respectively. Cohen’s Kappa was 69.20%, thus indicating good agreement. Changes in management were observed in 54% of the cases. CONCLUSIONCLE is a new diagnostic tool that has a significant clinical impact on the diagnosis and treatment of patients with uncertain diagnosis. 展开更多
关键词 confocal laser endomicroscopy In vivo microscopy Barret esophagus Gastrointestinal cancer Pancreatic cyst Biliary strictures
暂未订购
Clinical features and in vivo confocal microscopy assessment in 12 patients with ocular cicatricial pemphigoid 被引量:2
11
作者 Qin Long Ya-Gang Zuo +3 位作者 Xue Yang Ting-Ting Gao Jie Liu Ying Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第5期730-737,共8页
AIM: To describe the clinical features and microstructural characteristics assessed by in vivo confocal microscopy(IVCM) in patients with ocular cicatricial pemphigoid(OCP).· METHODS: A descriptive, uncontr... AIM: To describe the clinical features and microstructural characteristics assessed by in vivo confocal microscopy(IVCM) in patients with ocular cicatricial pemphigoid(OCP).· METHODS: A descriptive, uncontrolled case series study. Patients diagnosed with OCP were examined by clinical history, slit-lamp biomicroscopy features and IVCM images. The results of direct immunofluorescence(DIF) biopsies and indirect immunofluorescence(IIF) were also recorded. Local and systemic immunosuppressive therapy were administered and adjusted according to response.·RESULTS: A total of 12 consecutive OCP patients(7male, 5 female; mean age 60.42 ±10.39y) were recruited.All patients exhibited bilateral progressive conjunctival scarring and recurrent chronic conjunctivitis was the most frequent clinical pattern. The mean duration of symptoms prior to diagnosis of OCP was 2.95 ±2.85y(range: 5mo to 10y). The Foster classification varied from stage I to IV and 20 eyes(83%) were within or greater than Foster stage Ⅲ on presentation. Two of the 12patients(17%) demonstrated positive DIF; 3 of the 12(25%) patients reported positive IIF. The mean duration of the follow-up period was 20.17 ±11.88mo(range: 6 to48mo). IVCM showed variable degrees of abnormality in the conjuctiva-cornea and conjuctival scarring was detected in all the involved eyes. Corneal stromal cell activation and dendritic cell infiltration presented asocular surface inflammation, ocular surface keratinization along with the destroyed Vogt palisades was noted in eyes with potential limbal stem cell deficiency. After treatment, remission of ocular surface inflammation was achieved in all the patients, 18 eyes(75%) remained stable, 6 eyes(25%) had recurrent conjunctivitis and cicatrization in 2 eyes(8%) was progressing.· CONCLUSION: As an autoimmune disease, OCP manifests as variable degrees of clinical and laboratory abnormalities with both local and systemic immunosuppressive treatment playing important roles in disease therapy. IVCM can be as a valuable non-invasive technique to assess ocular surface changes in a cellular level with a potential value for providing diagnostic evidence and monitoring therapeutic effects during follow-up. 展开更多
关键词 ocular cicatricial pemphigoid ocular surface disease in vivo confocal microscopy
原文传递
EFFECT OF THE TOTAL SAPONIN OF DIPSACUS ASPER ON INTRACELLULAR FREE CALCIUM CONCENTRATION IN THE CELLULAR MODEL OF ALZHEIMER'S DISEASE-SCANNING CONFOCAL MICROSCOPY 被引量:2
12
作者 钱亦华 任惠民 +3 位作者 胡海涛 刘勇 杨广德 王春梅 《Academic Journal of Xi'an Jiaotong University》 2001年第2期159-163,共5页
Objective To study the effect of ginsenoside Rb1 and total saponin of dipsacus asper on intracellular free calcium concentration mediated by β amyloid protein.So as to lay a foundation for developing effective Chines... Objective To study the effect of ginsenoside Rb1 and total saponin of dipsacus asper on intracellular free calcium concentration mediated by β amyloid protein.So as to lay a foundation for developing effective Chinese traditional medicine to treat Alzheimer’s disease.Methods The technique of laser scanning confocal microscopy combining primary cultured neurons was adopted to quantitatively analyze the change of [Ca 2+ ] i.Results The [Ca 2+ ] i of primary cultured hippocampal neurons was nmol·L -1 on basal levels.Control group showed obvious change of calcium vibration,[Ca 2+ ] i was elevated to nmol·L -1 .The peak of [Ca 2+ ] i of Rb1 group reached nmol·L -1 and was lower than that of control group .The tSDA group displayed distinct change of calcium vibration too,and [Ca 2+ ] i reached nmol·L -1 .There was a significant difference in [Ca 2+ ] i between control and tSDA group .Conclusion The research indicated that one of mechanisms by which Rb1 and tSDA protected the neurons was to maintain the balance of [Ca 2+ ] i. 展开更多
关键词 cultured neurons β amyloid protein Alzheimer’s disease scanning confocal microscopy
暂未订购
In-situ confocal microscopy study on dissolution kinetics of calcium aluminate inclusions in CaO-Al_(2)O_(3)-SiO_(2)type steelmaking slags
13
作者 Guang Wang Muhammad Nabeel +2 位作者 Wangzhong Mu A.B.Phillion Neslihan Dogan 《Journal of Iron and Steel Research International》 2025年第2期364-375,共12页
Dissolution kinetics of CaO·2Al_(2)O_(3)(CA_(2))particles in a synthetic CaO-Al_(2)O_(3)-SiO_(2)steelmaking slag system have been investigated using the high-temperature confocal laser scanning microscope.Effects... Dissolution kinetics of CaO·2Al_(2)O_(3)(CA_(2))particles in a synthetic CaO-Al_(2)O_(3)-SiO_(2)steelmaking slag system have been investigated using the high-temperature confocal laser scanning microscope.Effects of temperature(i.e.,1500,1550,and 1600℃)and slag composition on the dissolution time of CA_(2)particles are investigated,along with the time dependency of the projection area of the particle during the dissolution process.It is found that the dissolution rate was enhanced by either an increase in temperature or a decrease in slag viscosity.Moreover,a higher ratio of CaO/Al_(2)O_(3)(C/A)leads to an increased dissolution rate of CA_(2)particle at 1600℃.Thermodynamic calculations suggested the dissolution product,i.e.,melilite,formed on the surface of the CA_(2)particle during dissolution in slag with a C/A ratio of 3.8 at 1550℃.Scanning electron microscopy equipped with energy dispersive X-ray spectrometry analysis of as-quenched samples confirmed the dissolution path of CA_(2)particles in slags with C/A ratios of 1.8 and 3.8 as well as the melilite formed on the surface of CA_(2)particle.The formation of this layer during the dissolution process was identified as a hindrance,impeding the dissolution of CA_(2)particle.A valuable reference for designing or/and choosing the composition of top slag for clean steel production is provided,especially using calcium treatment during the secondary refining process. 展开更多
关键词 In-situ observation Dissolution kinetics confocal laser scanning microscope Calcium aluminate inclusion Steelmaking slag Clean steel
原文传递
Software for automated classification of probe-based confocal laser endomicroscopy videos of colorectal polyps 被引量:8
14
作者 Barbara André Tom Vercauteren +3 位作者 Anna M Buchner Murli Krishna Nicholas Ayache Michael B Wallace 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第39期5560-5569,共10页
AIM:To support probe-based confocal laser endomi-croscopy (pCLE) diagnosis by designing software for the automated classification of colonic polyps. METHODS:Intravenous fluorescein pCLE imaging of colorectal lesions w... AIM:To support probe-based confocal laser endomi-croscopy (pCLE) diagnosis by designing software for the automated classification of colonic polyps. METHODS:Intravenous fluorescein pCLE imaging of colorectal lesions was performed on patients under-going screening and surveillance colonoscopies, followed by polypectomies. All resected specimens were reviewed by a reference gastrointestinal pathologist blinded to pCLE information. Histopathology was used as the criterion standard for the differentiation between neoplastic and non-neoplastic lesions. The pCLE video sequences, recorded for each polyp, were analyzed off-line by 2 expert endoscopists who were blinded to the endoscopic characteristics and histopathology. These pCLE videos, along with their histopathology diagnosis, were used to train the automated classification software which is a content-based image retrieval technique followed by k-nearest neighbor classification. The performance of the off-line diagnosis of pCLE videos established by the 2 expert endoscopists was compared with that of automated pCLE software classification. All evaluations were performed using leave-one-patient- out cross-validation to avoid bias. RESULTS:Colorectal lesions (135) were imaged in 71 patients. Based on histopathology, 93 of these 135 lesions were neoplastic and 42 were non-neoplastic. The study found no statistical significance for the difference between the performance of automated pCLE software classification (accuracy 89.6%, sensitivity 92.5%, specificity 83.3%, using leave-one-patient-out cross-validation) and the performance of the off-line diagnosis of pCLE videos established by the 2 expert endoscopists (accuracy 89.6%, sensitivity 91.4%, specificity 85.7%). There was very low power (< 6%) to detect the observed differences. The 95% confidence intervals for equivalence testing were:-0.073 to 0.073 for accuracy, -0.068 to 0.089 for sensitivity and -0.18 to 0.13 for specificity. The classification software proposed in this study is not a "black box" but an informative tool based on the query by example model that produces, as intermediate results, visually similar annotated videos that are directly interpretable by the endoscopist. CONCLUSION:The proposed software for automated classification of pCLE videos of colonic polyps achieves high performance, comparable to that of off-line diagnosis of pCLE videos established by expert endoscopists. 展开更多
关键词 Colorectal neoplasia Computer-aided diag-nosis Content-based image retrieval Nearest neigh-bor classification software Probe-based confocal laserendomicroscopy
暂未订购
Needle-based confocal endomicroscopy in the discrimination of mucinous from non-mucinous pancreatic cystic lesions 被引量:4
15
作者 Helga Bertani Raffaele Pezzilli +6 位作者 Flavia Pigo Mauro Bruno Claudio De Angelis Guido Manfredi Gabriele Delconte Rita Conigliaro Elisabetta Buscarini 《World Journal of Gastrointestinal Endoscopy》 2021年第11期555-564,共10页
BACKGROUND Pancreatic cystic lesions(PCLs)are considered a precursor of pancreatic cancer.Needle-based confocal endomicroscopy(nCLE)is an imaging technique that enables visualization of the mucosal layer to a micron r... BACKGROUND Pancreatic cystic lesions(PCLs)are considered a precursor of pancreatic cancer.Needle-based confocal endomicroscopy(nCLE)is an imaging technique that enables visualization of the mucosal layer to a micron resolution.Its application has demonstrated promising results in the distinction of PCLs.This study evaluated the utility of nCLE in patients with indeterminate PCLs undergoing endoscopic ultrasound fine-needle aspiration(EUS-FNA)to distinguish mucinous from non-mucinous lesions.AIM To evaluate the accuracy of nCLE in indeterminate PCLs undergoing EUS-FNA to distinguish mucinous from non-mucinous lesions.METHODS Patients who required EUS-FNA between 2015 and 2017 were enrolled prospectively.During EUS-FNA,confocal imaging,analyses of the tumor markers carcinoembryonic antigen and amylase,and cytologic examination were conducted.All patients were followed for at least 12 mo and underwent laboratory testing and computed tomography scanning or magnetic resonance imaging.nCLE videos were independently reviewed by 6 observers to reach a final diagnosis(mucinous vs non-mucinous)based on criteria derived from previous studies;if there was disagreement>20%,a final diagnosis was discussed after consensus re-evaluation.The sensitivity,specificity,and accuracy of nCLE were calculated.Adverse events were recorded.RESULTS Fifty-nine patients were included in this study.Final diagnoses were derived from surgery in 10 patients,cytology in 13,and imaging and multidisciplinary team review in 36.Three patients were excluded from final diagnosis due to problems with nCLE acquisition.Fifty-six patients were included in the final analysis.The sensitivity,specificity,and accuracy of nCLE were 80%[95%confidence interval(CI):65-90],100%(95%CI:72-100),and 84%(95%CI:72-93),respectively.Postprocedure acute pancreatitis occurred in 5%.CONCLUSION EUS-nCLE performs better than standard EUS-FNA for the diagnosis of indeterminate PCL. 展开更多
关键词 Needle-based confocal endomicroscopy Pancreatic cystic lesion Pancreatic adenocarcinoma Endoscopic ultrasound Endoscopic ultrasound fine-needle aspiration Intraductal papillary mucinous neoplasm Serous cyst adenoma
暂未订购
Corneal nerve changes by anti-glaucoma medications examined by in vivo confocal microscopy
16
作者 Xin-Yuan Zhu Qing-Shu Ge +7 位作者 Zong-Yi Li Long-Fang Zhou Qian-Wen Bu Ying Su Xin-Jie Wang Qing-Jun Zhou Xiao-Jing Pan Die Hu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第9期1645-1653,共9页
AIM:To evaluate the effects of antiglaucoma eye drops on corneal nerves by in vivo confocal microscopy(IVCM).METHODS:This study comprised 79 patients diagnosed with glaucoma and 16 healthy control individuals.Among th... AIM:To evaluate the effects of antiglaucoma eye drops on corneal nerves by in vivo confocal microscopy(IVCM).METHODS:This study comprised 79 patients diagnosed with glaucoma and 16 healthy control individuals.Among the glaucoma patients,54 were treated with medication,while 25 remained untreated.Central corneal images were evaluated by IVCM,and then ACCMetrics was used to calculate the following parameters:corneal nerve fiber density(CNFD),branch density(CNBD),fiber length(CNFL),total branch density(CTBD),fiber area(CNFA),fiber width(CNFW),and fractal dimension(CNFrD).The correlation between IVCM parameters and drugs was evaluated using non-parametric measurements of Spearman’s rank correlation coefficient.RESULTS:The CNFD was reduced in glaucoma groups compared to healthy subjects(P<0.01).Patients using anti-glaucoma medications exhibited poorer confocal parameters compared to untreated patients.As the number of medications and usage count increased,CNFD,CNBD,CNFL,CTBD,CNFA,and CNFrD experienced a decline,while CNFW increased(all P<0.01).For the brinzolamide-therapy group,there was a significant decrease in CNFD and CNFL compared to the other monotherapy groups(P<0.001).In the absence of medication,CNFD in males was lower than that in females(P<0.05).Among patients under medication therapy,CNFD remained consistent between males and females.CONCLUSION:Antiglaucoma eye drops affect the microstructure of corneal nerves.IVCM and ACCMetrics are useful tools that could be used to evaluate the corneal nerve changes. 展开更多
关键词 glaucoma therapy corneal nerve fibers in vivo confocal microscopy ACCMetrics
原文传递
Real-time in vivo distal margin selection using confocal laser endomicroscopy in transanal total mesorectal excision for rectal cancer
17
作者 Jie Tan Hong-Li Ji +7 位作者 Yao-Wen Hu Zhi-Ming Li Bao-Xiong Zhuang Hai-Jun Deng Ya-Nan Wang Ji-XiangZheng Wei Jiang Jun Yan 《World Journal of Gastrointestinal Surgery》 SCIE 2022年第12期1375-1386,共12页
BACKGROUND Transanal total mesorectal excision(TaTME)allows patients with ultralow rectal cancer to be treated with sphincter-saving surgery.However,accurate delineation of the distal resection margin(DRM),which is es... BACKGROUND Transanal total mesorectal excision(TaTME)allows patients with ultralow rectal cancer to be treated with sphincter-saving surgery.However,accurate delineation of the distal resection margin(DRM),which is essential to achieve R0 resection for low rectal cancer in TaTME,is technically demanding.AIM To assess the feasibility of optical biopsy using probe-based confocal laser endomicroscopy(pCLE)to select the DRM during TaTME for low rectal cancer.METHODS A total of 43 consecutive patients who were diagnosed with low rectal cancer and scheduled for TaTME were prospectively enrolled from January 2019 to January 2021.pCLE was used to determine the distal edge of the tumor as well as the DRM during surgery.The final pathological report was used as the gold standard.The diagnostic accuracy of pCLE examination was calculated.RESULTS A total of 86 pCLE videos of 43 patients were included in the analyses.The sensitivity,specificity and accuracy of real-time pCLE examination were 90.00%[95%confidence interval(CI):76.34%-97.21%],86.96%(95%CI:73.74%-95.06%)and 88.37%(95%CI:79.65%-94.28%),respectively.The accuracy of blinded pCLE reinterpretation was 86.05%(95%CI:76.89%-92.58%).Furthermore,our results show satisfactory interobserver agreement(κ=0.767,standard error=0.069)for the detection of cancer tissue by pCLE.There were no positive DRMs(≤1 mm)in this study.The median DRM was 7 mm[interquartile range(IQR)=5-10 mm].The median Wexner score was 5(IQR=3-6)at 6 mo after stoma closure.CONCLUSION Real-time in vivo pCLE examination is feasible and safe for selecting the DRM during TaTME for low rectal cancer(clinical trial registration number:NCT04016948). 展开更多
关键词 Transanal total mesorectal excision Probe-based confocal laser endomicroscopy Optical biopsy Distal resection margin Low rectal cancer
暂未订购
Probe based confocal laser endomicroscopy of the pancreatobiliary system 被引量:7
18
作者 Majid A Almadi Helmut Neumann 《World Journal of Gastroenterology》 SCIE CAS 2015年第44期12696-12708,共13页
AIM:To review applications of confocal laser endomicroscopy(CLE) in pancreatobiliary lesions and studies that assessed training and interpretation of images. METHODS: A computerized literature search was performed usi... AIM:To review applications of confocal laser endomicroscopy(CLE) in pancreatobiliary lesions and studies that assessed training and interpretation of images. METHODS: A computerized literature search was performed using OVID MEDLINE, EMBASE, Cochrane library, and the ISI Web of Knowledge from 1980 to October 2014. We also searched abstracts from major meetings that included the Digestive Disease Week, Canadian Digestive Disease Week and the United European Gastroenterology Week using a combination of controlled vocabulary and text words related to p CLE, confocal, endomicroscopy, probe-based confocal laser endomicroscopy, and bile duct to identify reports of trials. In addition, recursive searches and crossreferencing was performed, and manual searches of articles identified after the initial search was also completed. We included fully published articles and those in abstract form. Given the relatively recent introduction of CLE we included randomized trials and cohort studies.R E S U LT S : In the evaluation of indeterminate pancreatobiliary strictures CLE with ERCP compared to ERCP alone can increase the detection of cancerous strictures with a sensitivity of(98% vs 45%) andhas a negative predictive value(97% vs 69%), but decreased the specificity(67% vs 100%) and the positive predictive value(71% vs 100%) when compared to index pathology. Modifications in the classification systems in indeterminate biliary strictures have increased the specificity of p CLE from 67% to 73%. In pancreatic cystic lesions there is a need to develop similar systems to interpret and characterize lesions based on CLE images obtained. The presence of superficial vascular network predicts serous cystadenomas accurately. Also training in acquiring and interpretation of images is feasible in those without any prior knowledge in CLE in a relatively simple manner and computer-aided diagnosis software is a promising innovation. CONCLUSION: The role of p CLE in the evaluation of pancreatobiliary disorders might be better suited for those with an intermediate and low probability. 展开更多
关键词 PROBE BASED confocal laser ENDOmicroscopy confocal
暂未订购
Classification of histological severity of Helicobacter pylori-associated gastritis by confocal laser endomicroscopy 被引量:19
19
作者 Peng Wang Rui Ji +5 位作者 Tao Yu Xiu-Li Zuo Chang-Qing Li Zhen Li Yan-Qing Li Cheng-Jun Zhou 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第41期5203-5210,共8页
AIM: To classify the histological severity of Helicobacter pylori (H. pylori) infection-associated gastritis by confocal laser endomicroscopy (CLE). METHODS: Patients with upper gastrointestinal symptoms or individual... AIM: To classify the histological severity of Helicobacter pylori (H. pylori) infection-associated gastritis by confocal laser endomicroscopy (CLE). METHODS: Patients with upper gastrointestinal symptoms or individuals who were screened for gastric cancer were enrolled in this study. Histological severity of H. pylori infection-associated gastritis was graded according to the established CLE criteria. Diagnostic value of CLE for histo-logical gastritis was investigated and compared with that of white light endoscopy (WLE). Targeted biopsies from the sites observed by CLE were performed. RESULTS: A total of 118 consecutive patients with H. pylori infection-associated gastritis were enrolled in this study. Receiver operating characteristic curve analysis showedthat the sensitivity and specifi city of CLE were 82.9% and 90.9% for the diagnosis of H. pylori infection, 94.6% and 97.4% for predicting gastric normal mucosa, 98.5% and 94.6% for predicting histological active inflammation, 92.9% and 95.2% for predicting glan-dular atrophy, 98.6% and 100% for diagnosing intes-tinal metaplasia, respectively. Post-CLE image analysis showed that goblet cells and absorptive cells were the two most common parameters on the CLE-diagnosed intestinal metaplasia (IM) images (P < 0.001). More his-tological lesions of the stomach could be found by CLE than by WLE (P < 0.001). CONCLUSION: CLE can accurately show the histological severity of H. pylori infection-associated gastritis. Mapping IM by CLE has a rather good diagnostic accuracy. 展开更多
关键词 confocal laser endomicroscopy Helicobacter pylori GASTRITIS Classif ication HISTOLOGY
暂未订购
Effects of contact lens wearing on keratoconus:a confocal microscopy observation 被引量:4
20
作者 Somnath Ghosh Haliza A Mutalib +2 位作者 Sharanjeet Kaur Rituparna Ghoshal Shamala Retnasabapathy 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第2期228-234,共7页
AIM: To evaluate the corneal cell morphology of new keratoconus patients wearing two different types of rigid gas-permeable(RGP) contact lenses for 1y.METHODS: Thirty nine eyes of 39 new keratoconus patients were ... AIM: To evaluate the corneal cell morphology of new keratoconus patients wearing two different types of rigid gas-permeable(RGP) contact lenses for 1y.METHODS: Thirty nine eyes of 39 new keratoconus patients were selected and randomly fitted with two types of RGP contact lenses.Group 1 had 21 eyes with regular rigid gas-permeable(RRGP) contact lens and rest 18 eyes were in group 2 with specially designed rigid gas-permeable(SRGP) contact lens.Corneal cell morphology was evaluated using a slit scanning confocal microscope at no-lens wear and after 1y of contact lens wearing.RESULTS: After 1y of contact lens wearing in group 1,the mean anterior and posterior stromal keratocyte density were significantly less(P=0.006 and P=0.001,respectively) compared to no-lens wear.The mean cell area of anterior and posterior stromal keratocyte were also significantly different(P=0.005 and P=0.001) from no-lens wear.The anterior and posterior stromal haze increased by 18.74% and 23.81%,respectively after 1y of contact lens wearing.Whereas in group 2,statistically significant changes were observed only in cell density & area of anterior stroma(P=0.001 and P=0.001,respectively) after 1y.While,level of anterior and posterior stromal haze increased by 16.67% and 11.11% after 1y of contact lens wearing.Polymegathism and pleomorphism also increased after 1y of contact lens wearing in both the contact lens groups.CONCLUSION: Confocal microscopy observation shows the significant alterations in corneal cell morphology of keratoconic corneas wearing contact lenses especially in group 1.The type of contact lens must be carefully selected to minimize changes in corneal cell morphology. 展开更多
关键词 KERATOCONUS contact lens CORNEA confocal microscopy
原文传递
上一页 1 2 250 下一页 到第
使用帮助 返回顶部