期刊文献+
共找到4,596篇文章
< 1 2 230 >
每页显示 20 50 100
Studying a kind of portable ultra-bright microfocus x-ray source
1
作者 王凯歌 王雷 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第5期1807-1813,共7页
This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusi... This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusing system and a metal target. A crystal Lanthanum Hexaboride cathode, a Wehnelt grid and an extracted electrode compose the triode electrode electron-gun system. Two equal radius cylinder electrodes form the focusing system. The key factors determining the focus properties of the electron beam such as the ratio Dw/H, grid bias Vg, and the properties of the extracted electrode arc numerically studied. The calculated results reveal that when Dw/H, Vg, the length of the extracted electrode, and the distance between the grid and the extracted electrode equals 5, q).6 kV, 10 mm, and 8 mm respectively, the electron beam focal spot can be concentrated down to 9 μm in radius and a reasonable focal length about 72.5 mm can be achieved, at the same time, the cathode emission currents can be as high as 30 mA. 展开更多
关键词 microfocus x-ray source high brightness micro-focal spot Monte-Carlo method
原文传递
In-line phase contrast for weakly absorbing materials with a microfocus x-ray source
2
作者 章迪 李政 +2 位作者 黄志峰 禹爱民 沙薇 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第8期1731-1737,共7页
For weakly absorbing materials, image contrast can be enhanced by phase contrast in formation. The effectiveness of the in-line phase contrast technique relies on its ability to record intensity data which contain inf... For weakly absorbing materials, image contrast can be enhanced by phase contrast in formation. The effectiveness of the in-line phase contrast technique relies on its ability to record intensity data which contain information on the x- ray's phase shift. Four kinds of approaches to the relationship between intensity distribution and phase shift axe reviewed and discussed. A micro-focal x-ray source with high geometrical magnification is used to acquire phase contrast images. A great improvement on image quality is shown and geometrical parameters axe modified for comparison between different imaging positions. 展开更多
关键词 in-line phase contrast intensity distribution microfocus Fresnel diffraction
原文传递
Influence of tube voltage and current on in-line phase contrast imaging using a microfocus x-ray source
3
作者 李晨 李政 +1 位作者 禹爱民 黎成权 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第8期2319-2324,共6页
In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehens... In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med. Phys. 31 2378-2384 (2004)] is reviewed. The influence of x-ray source and detector on the image is discussed. Experiments using a microfocus x-ray source and a CCD detector are conducted, which show the role of two key factors on imaging: the tube voltage and tube current. High tube current and moderate tube voltage are suggested for imaging. 展开更多
关键词 x-ray in-line phase contrast imaging Wigner distribution
原文传递
Effects of Tube Voltage on Phase-Contrast Imaging for Different Microfocus X-Ray Tubes
4
作者 Jianbao Gui Zhanli Hu +1 位作者 Peter Z. Wu Hairong Zheng 《Engineering(科研)》 2013年第10期590-594,共5页
In the past decade, phase-contrast imaging (PCI) has become a hot research with an increased improvement of the image contrast with respect to conventional absorption radiography. In this paper, effects of tube voltag... In the past decade, phase-contrast imaging (PCI) has become a hot research with an increased improvement of the image contrast with respect to conventional absorption radiography. In this paper, effects of tube voltage (kVp) on propagation-based phase-contrast imaging have been investigated with two types of microfocus x-ray tubes, a conventional sealed x-ray tube with the focal spot size of 13 - 20 μm and an open x-ray tube with minimum focal spot size less than 2 μm. A cooled x-ray CCD detector with the pixel size of 24 μm was used to acquire digital images. Two thin plastic sheets with different thickness were used as radiography phantoms. Two different phenomena were observed for the two x-ray tubes. For the open tube, phase-contrast effect has a slight drop with the increasing of tube voltage, however, it is opposite for the sealed tube. A further investigation indicates that the variation of focal spot size causes the abnormal result for the sealed tube. It also shows that phase-contrast effect is more sensitive to focal spot size than tube voltage. 展开更多
关键词 PHASE-CONTRAST Imaging EDGE Enhancement x-ray TUBE VOLTAGE
暂未订购
Optical characterization of X-ray polymer refractive lenses using a microfocus X-ray grating interferometer
5
作者 Dongxu Qin Lian Xue +5 位作者 Yifan Ding Ziwen Huang Lei Yang Zhaofeng Kang Keyi Wang Shuai Zhao 《Chinese Optics Letters》 2025年第4期143-148,共6页
Two-photon polymerization lithography is a technique that provides hundreds of nanometer resolution and full geometric freedom.Several X-ray polymer refractive lenses created by this technique were characterized using... Two-photon polymerization lithography is a technique that provides hundreds of nanometer resolution and full geometric freedom.Several X-ray polymer refractive lenses created by this technique were characterized using differential phase contrast imaging(DPCI)with a microfocus X-ray grating interferometer.The beam deflection angle and wavefront phase shift of the X-ray beam through the lens were obtained.Comparative tests using synchrotron radiation sources showed that the system could measure the surface shape of X-ray refractive lenses with an accuracy of 0.4μm.This study is important for improving the fabrication process and focusing performance of X-ray refractive lenses. 展开更多
关键词 differential phase contrast imaging x-ray polymer refractive lens microfocus x-ray grating interferometer optical characterization
原文传递
MAPPING THE DAMAGED ZONE AROUND THE CRACK TIP IN HIGH DENSITY POLYETHYLENE WITH SYNCHROTRON MICROFOCUS SMALL ANGLE X-RAY SCATTERING TECHNIQUE 被引量:3
6
作者 Hans-Friedrich Enderle Dieter Lilge +3 位作者 Stephan V.Roth Rainer Gehrke Jens Rieger 门永锋 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2010年第2期165-170,共6页
The structural changes around a crack tip in a high density polyethylene were investigated by means of scanning synchrotron microfocus small-angle X-ray scattering technique. The scattering data confirm the process of... The structural changes around a crack tip in a high density polyethylene were investigated by means of scanning synchrotron microfocus small-angle X-ray scattering technique. The scattering data confirm the process of craze structure development near a crack tip based on the evolution of voids. In addition, it was found that the main stress in the plastic zone near a crack tip exhibited a gradient distribution with respect to its strength and direction. The whole damaged area showed a strain distribution indicating a flow behavior toward the crack tip. 展开更多
关键词 High density polyethylene microfocus SAXS Crack tip Voids.
在线阅读 下载PDF
Scanning Microfocus Small Angle X-ray Scattering Study of the Avian Eggshell
7
作者 D. Lammie M. M. Bain +1 位作者 S. E. Solomon T. J. Wess 《Journal of Bionic Engineering》 SCIE EI CSCD 2006年第1期11-18,共8页
Synchrotron microfocus small angle X-ray scattering was used to investigate the nanostructure and microscopic variation of eggshells. It uses a microbeam allowing the ability to probe interactions between the organic ... Synchrotron microfocus small angle X-ray scattering was used to investigate the nanostructure and microscopic variation of eggshells. It uses a microbeam allowing the ability to probe interactions between the organic and inorganic components at nanometer level and is ideal for mapping over small areas to obtain a detailed analysis of structural variations. Thin sections of eggshells were scanned from the shell membrane (inner) to the cuticle (outer) surface. The data collected was used to produce two-dimensional maps showing microscopic changes within the different layers of the eggshell. The structural alterations ap- parently could have implications at the macroscopic level of the resulting eggshell. As the organic matrix is embedded within the eggshell this may contribute to the variations observed in calcite crystal form and texture, Structural information obtained about a biomaterial at different length scales is important in relating the structure to its functional properties. This knowledge and the principles behind the formation of biomaterials could be used in the attempt of bioengineering new systems. 展开更多
关键词 biomaterial EGGSHELL NANOSTRUCTURE microfocus small angle x-ray scattering
在线阅读 下载PDF
Response estimation and evaluation of direct-conversion dual-layer perovskite X-ray detectors:a numerical study with a cascaded signal model
8
作者 Han Cui Yu-Hang Tan +7 位作者 Xin Zhang Hao-Di Wu Ting Su Jiong-Tao Zhu Hai-Rong Zheng Dong Liang Xiang-Ming Sun Yong-Shuai Ge 《Nuclear Science and Techniques》 2026年第2期156-168,共13页
This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation ... This study aims to investigate the responses of a perovskite-based direct-conversion dual-layer flat-panel detector(DL-FPD)numerically.To this end,the X-ray sensitivity,spatial resolution quantified by the modulation transfer function(MTF),and detective quantum efficiency(DQE)of the DL-FPD are evaluated numerically using a linear cascade model.In addition,both the single-crystal(SC)and polycrystalline(PC)structures of MAPbI_(3)are investigated,along with various other key parameters such as the material thickness,electric field strength,X-ray beam spectrum,and electronic readout noise.The results demonstrate that SC perovskite consistently exhibits better performance than PC perovskite owing to fewer material defects.Increasing the layer thickness may decrease the MTF,but can also enhance the sensitivity and DQE.Moreover,appropriately increasing the external electric field within the material can improve the sensitivity,MTF,and DQE.Finally,reducing the electronic readout noise can significantly enhance the DQE for low-dose imaging.This study demonstrates the potential of high-quality dual-energy X-ray imaging using direct-conversion perovskite DL-FPDs. 展开更多
关键词 x-ray imaging Dual-layer flat-panel detector Perovskite x-ray detector
在线阅读 下载PDF
Impacts of X-ray energy and beam size on CD-SAXS measurement precision
9
作者 Xu-Yang Qin Bing Guo +7 位作者 Nan Pan Xin-Hao Gao Shu-Min Yang Chun-Xia Hong Ying Wang Xiu-Hong Li Chun-Ming Yang Feng-Gang Bian 《Nuclear Science and Techniques》 2026年第4期65-78,共14页
With the development of the semiconductor industry below the 7 nm scale,critical dimension small-angle X-ray scattering(CD-SAXS)has emerged as a powerful tool for quantitatively measuring nanoscale deviations.In this ... With the development of the semiconductor industry below the 7 nm scale,critical dimension small-angle X-ray scattering(CD-SAXS)has emerged as a powerful tool for quantitatively measuring nanoscale deviations.In this study,the effects of X-ray beam size and photon energy on the accuracy of critical dimension measurements were investigated.Critical dimensions measured using beams with different spot sizes showed different deviations from the expected values.Beam sizes that were either too large or too small did not improve confidence intervals.As the incident energy increased,the X-ray transmission rate increased,while the scattering cross section decreased,resulting in a gradual decrease in the signal-to-noise ratio of the diffraction peaks,which reduced the accuracy of the CD-SAXS measurements.An optimal accuracy was obtained at 12 keV with a smaller beam size.Using an effective trapezoid model,the results yielded an average pitch of 100.4±0.2 nm,width of 49.8±0.2 nm,height of 130.0±0.2 nm,and a sidewall angle below 1.1°±0.1°.These results provide crucial guidance for the future development of CD-SAXS laboratories and the construction of X-ray machines as well as robust support for research in related fields. 展开更多
关键词 Critical dimension small-angle x-ray scattering Nonlinear fitting Beam size x-ray energy Chip
在线阅读 下载PDF
Effect of measurement reduction on synthetic aperture x-ray ghost imaging
10
作者 Haipeng Zhang Jie Tang +4 位作者 Nixi Zhao Changzhe Zhao Jianwen Wu Zhongliang Li Tiqiao Xiao 《Chinese Physics B》 2026年第1期457-465,共9页
The unique advantage of x-ray ghost imaging(XGI)is its potential in low dose radiology.One of the practical ways to reduce the radiation exposure is to reduce the measurements while remaining sufficient image quality.... The unique advantage of x-ray ghost imaging(XGI)is its potential in low dose radiology.One of the practical ways to reduce the radiation exposure is to reduce the measurements while remaining sufficient image quality.Synthetic aperture x-ray ghost imaging(SAXGI)is invented to achieve megapixel XGI with limited measurements,which is expected to implement XGI simultaneously with large field of view and low radiation exposure.In this paper,we experimentally investigate the effect of measurements reduction on the spatial resolution and image quality of SAXGI with standard sample and biomedical specimen.The results with a resolution chart demonstrated that at 360 measurements,SAXGI successfully retrieved the sample image of 1960×1960 pixels with spatial resolution of 4μm.With measurement reduction,the spatial resolution deteriorates but the sparser structures are still discernable.Even with measurements reduced to 10,a spatial resolution of 10μm can still be achieved by SAXGI.A biomedical sample of a fish specimen is employed to evaluate the method and the fish image of 2000×1000 pixels with an SSIM of 0.962 is reconstructed by SAXGI with 770measurements,corresponding to an accumulative exposure reduction of more than 2 times.With the measurements reduced to 10 which corresponds to 1/160 of the accumulative radiation exposure for conventional radiology,bulky structure like the fish skeleton can still be definitely discerned and the SSIM for the reconstructed image still retained 0.9179.Results of this paper demonstrate that measurements reduction is practicable for the radiation exposure reduction of the sample,which implicates that SAXGI with limited measurements is an efficient solution for low dose radiology. 展开更多
关键词 x-ray ghost imaging synthetic aperture x-ray imaging low dose radiology compressed sensing algorithm
原文传递
Tracing equatorward and poleward boundaries of the magnetospheric cusp from a simulated X-ray image
11
作者 Xue Wang TianRan Sun +4 位作者 C.Philippe Escoubet Andy Read YiHong Guo Steve Sembay Chi Wang 《Earth and Planetary Physics》 2026年第1期144-155,共12页
A large-scale view of the magnetospheric cusp is expected to be obtained by the Soft X-ray Imager(SXI)onboard the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE).However,it is challenging to trace the three-d... A large-scale view of the magnetospheric cusp is expected to be obtained by the Soft X-ray Imager(SXI)onboard the Solar wind Magnetosphere Ionosphere Link Explorer(SMILE).However,it is challenging to trace the three-dimensional cusp boundary from a two-dimensional X-ray image because the detected X-ray signals will be integrated along the line of sight.In this work,a global magnetohydrodynamic code was used to simulate the X-ray images and photon count images,assuming an interplanetary magnetic field with a pure Bz component.The assumption of an elliptic cusp boundary at a given altitude was used to trace the equatorward and poleward boundaries of the cusp from a simulated X-ray image.The average discrepancy was less than 0.1 RE.To reduce the influence of instrument effects and cosmic X-ray backgrounds,image denoising was considered before applying the method above to SXI photon count images.The cusp boundaries were reasonably reconstructed from the noisy X-ray image. 展开更多
关键词 SMILE mission x-ray image cusp boundary
在线阅读 下载PDF
Three-dimensional characterization of intermetallic compound formation in magnesium alloys with micro X-ray computed tomography
12
作者 SUN Wei HU Xiao-juan +5 位作者 DENG Yang-chao YANG Yang YAO Hu ZHANG Yong-hong ZHANG Rui-feng ZENG Guang 《Journal of Central South University》 2026年第1期160-174,共15页
This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both commo... This comprehensive study investigates the formation and evolution of intermetallic compounds during the solidification process of magnesium alloys using advanced micro X-ray computed tomography.By analyzing both common industrial Mg-Al-Zn alloys and a novel rare earth-containing Mg-Ni-Gd-Y alloy,we aim to characterize the nucleation,growth,and distribution of Al-Mn and eutectic intermetallics across various stages of solidification.The non destructive imaging technique employed in this research provides high-resolution,three-dimensional insights into the microstructural development,allowing for a detailed examination of the morphology,spatial arrangement,and interconnectivity of intermetallic phases.This approach overcomes limitations of traditional two-dimensional metallographic methods,offering a more comprehensive understanding of the complex three-dimensional structures formed during solidification. 展开更多
关键词 magnesium alloy x-ray computed tomography SOLIDIFICATION INTERMETALLICS DEFECTS
在线阅读 下载PDF
Comparative evaluation of single-mask and single-shot X-ray phase-contrast and dual-energy computed tomography analyses on soft-tissue phantom
13
作者 Chang Li Xiao-Xuan Ren +6 位作者 Liang-Liang Lv Shu-Yi Sun Jian Zhang Yin-Qi Lei Xiao-Dong Pan Cui Zhang Gong-Ping Li 《Nuclear Science and Techniques》 2026年第5期241-251,共11页
In clinical diagnosis,conventional X-ray absorption-contrast computed tomography(XACT)technology cannot effectively differentiate diseased tissues from the healthy ones.X-ray phase-contrast CT(XPCT)and dual-energy CT(... In clinical diagnosis,conventional X-ray absorption-contrast computed tomography(XACT)technology cannot effectively differentiate diseased tissues from the healthy ones.X-ray phase-contrast CT(XPCT)and dual-energy CT(DECT),emerging X-ray imaging technologies with superior diagnostic capabilities,address this issue through different principles.While both XPCT and DECT have advantages and disadvantages in medical applications,their systematic comparison is lacking.Using GEANT4 and MATLAB,in this study,we established an X-ray phase-contrast imaging(XPCI)model based on single-mask and single-shot edge illumination for fast XPCT imaging,comparing it with DECT on soft-tissue phantom.XACT served as a reference for comparison.The study introduces an evaluation system using statistical measures including absolute error,mean absolute error,structure similarity index measure,peak signal-to-noise ratio,and contrast-to-noise ratio.Results show XPCT images are superior to DECT.The XPCI model can be improved on existing medical CT for widespread medical application. 展开更多
关键词 Comparative evaluation x-ray phase-contrast CT Edge illumination Dual-energy CT GEANT4
在线阅读 下载PDF
Enhancing Heat Transfer in X-ray Tube by van der Waals Heterostructures-based Thermionic Emission
14
作者 LI Qian-qian HUANG Sun-chao +8 位作者 CHEN Su-guo WANG Yue SHI Xi-hang ZHANG Xiao-qiu-yan HU Min ZHANG Ping WANG Shao-meng ZHANG Chao GONG Yu-bin 《真空电子技术》 2026年第1期21-27,共7页
Van der Waals(vdW)heterostructures have attracted much attention due to their distinctive optical,electrical,and thermal properties,demonstrating promising potential in areas such as photocatalysis,ultrafast photonics... Van der Waals(vdW)heterostructures have attracted much attention due to their distinctive optical,electrical,and thermal properties,demonstrating promising potential in areas such as photocatalysis,ultrafast photonics,and free electron radiation devices.Particularly,they are promising platforms for studying thermionic emission.It is illustrated that using vdW heterostructure-based thermionic emission can enhance heat transfer in vacuum devices.As a proof of concept,the approach is demonstrated to offer a promising solution for the long-standing overheating issue in X-ray tubes.Specifically,it is shown that the saturated target temperature of a 2000 W X-ray tube can be reduced from around 1200℃ to 490℃.Additionally,it is also demonstrated that by reducing the height of the Schottky barrier formed in the vdW heterostructures,the thermionic cooling performance can be enhanced.The findings pave the way for the development of high-power X-ray tubes. 展开更多
关键词 x-ray tube Heat transfer Thermionic emission Thermionic cooling Van der Waals Heterostructures
在线阅读 下载PDF
Noncovalent Interaction-Mediated Space Charge Transition Facilitated Isolated Copper(I)-Iodide Clusters:Enabling High-Resolution X-Ray Imaging and Dynamic Encryption
15
作者 Zhao-Xing Gao Wen-Fei Wang +3 位作者 Mian-He Xu Shuai-Hua Wang Fa-Kun Zheng Guo-Cong Guo 《Aggregate》 2026年第2期241-249,共9页
The exploration of solvent-driven reversible structural transformation in clusters is crucial for advanced stimulus-responsive optical applications and understanding of structure-property relationships.Herein,we repor... The exploration of solvent-driven reversible structural transformation in clusters is crucial for advanced stimulus-responsive optical applications and understanding of structure-property relationships.Herein,we report a solvent-driven reversible trans-formation between two copper(I)clusters:[Cu(totp)(CH_(3)CN)_(3)][Cu_(2)I_(3)(totp)(DPPPy)]·CH_(3)CN 1 and Cu_(4)I_(4)(DPPPy)_(2)·0.5CH_(2)Cl_(2)2(totp=tri-o-tolylphosphine,DPPPy=2-[diphenylphosphino]pyridine).X-ray radioluminescence and encryption applications were studied based on structure-dependent photophysical properties difference.The noncovalent interaction-mediated space charge transition between isolated ion units of 1 enables more efficient thermally activated delayed fluorescence by reverse intersystem crossing,accounting for structure-dependent luminescence.Notably,compared to 2,1 exhibits a higher scintillation light yield of 14832 photons MeV^(-1),exceeding that of the commercial scintillator Bi_(4)Ge_(3)O_(12)(8000 photons MeV^(-1)),and a low X-ray detection limit of 22.49 nGy s^(-1),far below the typical diagnostic dose(5.5μGy s^(-1)).Furthermore,scintillating film fabricated by 1 achieves X-ray imaging with a high spatial resolution of 16 lp/mm.The reversible structural interconversion enables solvent-responsive luminescent switches,and thus,the dynamic encryption system capable of multistage decryption was developed.This work not only offers new insight into solvent-regulated clusters transformations but also provides a promising strategy for developing high-performance copper(I)clusters-based scintillators and stimulus-responsive optical devices. 展开更多
关键词 copper(I)-iodide clusters information encryption solvent-driven structural transformation x-ray imaging
在线阅读 下载PDF
Lattice Anchoring Stabilizesα-FAPbI_(3) Perovskite for High-Performance X-Ray Detectors
16
作者 Yu-Hua Huang Su-Yan Zou +5 位作者 Cong-Yi Sheng Yu-Chuang Fang Xu-Dong Wang Wei Wei Wen-Guang Li Dai-Bin Kuang 《Nano-Micro Letters》 2026年第1期337-354,共18页
Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection appl... Formamidinium lead iodide(FAPbI_(3))perovskite exhibits an impressive X-ray absorption coefficient and a large carrier mobility-lifetime product(μτ),making it as a highly promising candidate for X-ray detection application.However,the presence of larger FA^(+)cation induces to an expansion of the Pb-I octahedral framework,which unfortunately affects both the stability and charge carrier mobility of the corresponding devices.To address this challenge,we develop a novel low-dimensional(HtrzT)PbI_(3) perovskite featuring a conjugated organic cation(1H-1,2,4-Triazole-3-thiol,HtrzT^(+))which matches well with theα-FAPbI_(3) lattices in two-dimensional plane.Benefiting from the matched lattice between(HtrzT)PbI_(3) andα-FAPbI_(3),the anchored lattice enhances the Pb-I bond strength and effectively mitigates the inherent tensile strain of theα-FAPbI_(3) crystal lattice.The X-ray detector based on(HtrzT)PbI_(3)(1.0)/FAPbI_(3) device achieves a remarkable sensitivity up to 1.83×10^(5)μC Gy_(air)^(−1) cm^(−2),along with a low detection limit of 27.6 nGy_(air) s^(−1),attributed to the release of residual stress,and the enhancement in carrier mobility-lifetime product.Furthermore,the detector exhibits outstanding stability under X-ray irradiation with tolerating doses equivalent to nearly 1.17×10^(6) chest imaging doses. 展开更多
关键词 α-FAPbI_(3)perovskite Conjugated organic cation Lattice anchoring Phase stability x-ray detectors
在线阅读 下载PDF
Ultralow dark current soft X-ray detectors based on lead-free double perovskite Cs_(2)AgBiBr_(6)
17
作者 Long Cheng Lijuan Huang +15 位作者 Mulin Sun Ying Meng Yuan Li Tianyu Liu Pengju Tan Mingzhu Hu Huaqing Yang Xiaolan Ma Shunjie Yu Xiaohu Hou Yong Guan Junfa Zhu Xiaosong Liu Yu Li Shibing Long Qin Hu 《Journal of Semiconductors》 2026年第1期109-116,共8页
Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stabi... Soft X-ray detectors play a vital role in materials science,high-energy physics and medical imaging.Cs_(2)AgBiBr_(6),a lead-free double perovskite,has gained attention for its excellent optoelectronic properties,stability,and nontoxicity.However,its fast crystallization and requirement for high-temperature annealing(>250℃)often lead to inferior film quality,limiting its application in flexible devices.This study introduces an alloying strategy that significantly improves the quality of Cs_(2)AgBiBr_(6)thin films annealed at a reduced temperature of 150℃.Devices based on the alloyed thin films exhibit an ultra-low dark current of 0.32 nA·cm^(-2)and a quantum efficiency of 725%.Furthermore,the first successful integration of Cs_(2)AgBiBr_(6)with a thinfilm transistor backplane demonstrates its superior imaging performance,indicating that Cs_(2)AgBiBr_(6)is a promising material for next-generation soft X-ray sensors. 展开更多
关键词 soft x-ray detector lead-free double perovskite Cs_(2)AgBiBr_(6) ALLOYING IMAGING
在线阅读 下载PDF
基于高光谱和X-ray CT的苹果水心病无损检测方法
18
作者 于心圆 王振杰 +6 位作者 尤思聪 屠康 兰维杰 彭菁 朱丽霞 陈涛 潘磊庆 《智慧农业(中英文)》 2025年第4期108-118,共11页
[目的/意义]苹果“冰糖心”又称水心病,是一种常见的果实病害,严重的水心病果会随着储藏时间的增加发生霉变,造成食品安全隐患。为实现不同等级水心病苹果快速无损检测,本研究旨在构建有效的分级与可溶性固形物(Soluble Solids Content,... [目的/意义]苹果“冰糖心”又称水心病,是一种常见的果实病害,严重的水心病果会随着储藏时间的增加发生霉变,造成食品安全隐患。为实现不同等级水心病苹果快速无损检测,本研究旨在构建有效的分级与可溶性固形物(Soluble Solids Content,SSC)预测模型。[方法]本研究选取了230个富士苹果,其中正常、轻度、中度、重度水心苹果数量分别为113、61、47和9个,分别采集了400~1000 nm范围的反射光谱和X射线计算机断层成像(X-ray Computed Tomography,X-ray CT)数据,并测定了SSC含量。[结果和讨论]SSC随水心程度加剧呈上升趋势,重度水心苹果呈现更高的光谱反射率,X-ray CT扫描成像观察到水心区域的组织体积平均密度高于健康组织,基于三维重建算法实现不同等级水心苹果内部水心组织可视化分布。基于偏最小二乘判别分析(Partial Least Squares Discriminant Analysis,PLSDA)构建的不同水心程度苹果果实分级模型建模集和测试集准确率分别为98.7%和95.9%;构建不同水心程度苹果果实SSC回归模型,校正集决定系数(Correlation Coefficient of Calibration,R_(C)^(2))为0.962,均方根误差(Root Mean Squares Error of Calibration,RMSEC)为0.264,测试集决定系数(Correlation Coefficient of Prediction,R_(P)^(2))为0.879,均方根误差(Root Mean Squares Error of Prediction,RMSEP)为0.435。[结论]该研究构建的不同水心程度苹果果实分级模型能够实现苹果不同等级水心病的预测,构建的不同水心程度苹果果实SSC回归模型能够较好地预测苹果果实的SSC,为苹果水心病无损检测和品质评估提供了有效方法。 展开更多
关键词 水心病 高光谱成像技术 x-ray CT成像技术 可溶性固形物
在线阅读 下载PDF
Tests of Solar X-Ray Image Reconstruction:A New Index for Assessing Image Quality 被引量:1
19
作者 Zhen-Tong Li Wen-Hui Yu +2 位作者 Yang Su Wei Chen Wei-Qun Gan 《Research in Astronomy and Astrophysics》 2025年第3期76-89,共14页
Indirect X-ray modulation imaging has been adopted in a number of solar missions and provided reconstructed X-ray images of solar flares that are of great scientific importance.However,the assessment of the image qual... Indirect X-ray modulation imaging has been adopted in a number of solar missions and provided reconstructed X-ray images of solar flares that are of great scientific importance.However,the assessment of the image quality of the reconstruction is still difficult,which is particularly useful for scheme design of X-ray imaging systems,testing and improvement of imaging algorithms,and scientific research of X-ray sources.Currently,there is no specified method to quantitatively evaluate the quality of X-ray image reconstruction and the point-spread function(PSF)of an X-ray imager.In this paper,we propose percentage proximity degree(PPD)by considering the imaging characteristics of X-ray image reconstruction and in particular,sidelobes and their effects on imaging quality.After testing a variety of imaging quality assessments in six aspects,we utilized the technique for order preference by similarity to ideal solution to the indices that meet the requirements.Then we develop the final quality index for X-ray image reconstruction,QuIX,which consists of the selected indices and the new PPD.QuIX performs well in a series of tests,including assessment of instrument PSF and simulation tests under different grid configurations,as well as imaging tests with RHESSI data.It is also a useful tool for testing of imaging algorithms,and determination of imaging parameters for both RHESSI and ASO-S/Hard X-ray Imager,such as field of view,beam width factor,and detector selection. 展开更多
关键词 SUN flares-Sun x-rays gamma-rays-techniques image processing
在线阅读 下载PDF
Role of post-operative X-rays in distal-radius fractures among pediatric patients 被引量:1
20
作者 Ammar K Alomran Bandar A Alzahrani +4 位作者 Dana S Alamoud Layan S Alsultan Meshail M AlSaud Raneem G Althobaiti Badriah S Alruwaili 《World Journal of Orthopedics》 2025年第5期51-60,共10页
BACKGROUND In pediatric age group patients(<18 years old)treated operatively for distal radius/both bone fractures extending imaging beyond the initial postoperative period-particularly in uncomplicated cases-appea... BACKGROUND In pediatric age group patients(<18 years old)treated operatively for distal radius/both bone fractures extending imaging beyond the initial postoperative period-particularly in uncomplicated cases-appears to provide limited additional benefit.AIM To determine the necessary number of follow-up X-rays to use resources efficiently.METHODS Participants included in this study are pediatric age group patients who were treated operatively for distal radius/both bone fractures and were identified from a prospected collected data from the operating room database between the years 2009 and 2017.The data in the study included patients who had distal radius fractures and underwent fixation surgery(n=88).RESULTS When assessing the difference in the odds of conducting 1 or less X-ray compared to 2 or more X-rays in regard to the type of fixation,the only significant difference is the closed reduction fixation method.Patients who underwent closed reduction method procedure have significantly lower odds of having 2 more X-rays compared to those who didn’t have closed reduction method.Open reduction,internal fixation,and other fixation methods(close reduction and internal fixation,debridement,or epiphysiodesis)have higher odds of having two or more X-rays compared to patients who did not receive these methods;however,these odds are not statistically significant.CONCLUSION The findings of this study reveal notable absence of a statistically significant association between the frequency of postoperative X-rays and the outcome of children with distal radius fractures. 展开更多
关键词 x-ray Distal radius fractures PEDIATRICS ORTHOPEDIC FRACTURES
暂未订购
上一页 1 2 230 下一页 到第
使用帮助 返回顶部