期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Microbiological Contamination and Disinfection Procedures of Kitchen Sponges used in Food Services
1
作者 Eliandra Mirlei Rossi Diane Scapin +1 位作者 Williani Fabíola Grando Eduardo Cesar Tondo 《Food and Nutrition Sciences》 2012年第7期975-980,共6页
Kitchen sponges continue to be heavily used in Brazilian food services, even though they may be very contaminated. The objective of this study was to evaluate the microbiological contamination and the efficacy of two ... Kitchen sponges continue to be heavily used in Brazilian food services, even though they may be very contaminated. The objective of this study was to evaluate the microbiological contamination and the efficacy of two procedures for the disinfection of kitchen sponges used in Brazilian food services. Eighty sponges were collected from food services and then analyzed for the quantification heterotrophic microorganisms (HM), fecal coliforms (CF), Staphylococcus coagulase-positive (SA) microorganisms and to the investigation of the presence of Salmonella sp. (SAM). After that, the sponges were disinfected, separately, by either boiling water for five minutes or immersed in 200ppm sodium hypochlorite, for 10 minutes, added to a rinse with potable water. The results showed that sponges presented HM counts between 3.4 and 10.4 log CFU/sponge, with an average of 9.1 log CFU/sponge, and 76.25% of them presented CF with average counts of 8.4 log CFU/sponge. SA and SAM were found in 2.5% of samples. Both disinfection procedures were able to significantly reduce the bacterial counts, but the boiling method showed a greater reduction (99.9999%) than the method of disinfection by 200 ppm sodium hypochlorite (99.9%). Based on the results it was possible to conclude that kitchen sponges can be very contaminated, but simple disinfection procedure can be applied to significantly reduce the microbial contamination. 展开更多
关键词 Kitchen Sponges microbiological contamination DISINFECTION Food Services CROSS-contamination
暂未订购
Viral Contamination Source in Clinical Microbiology Laboratory 被引量:2
2
作者 WANG Xin Ling SONG Juan +4 位作者 SONG Qin Qin YU Jie LUO Xiao Nuan WU Gui Zhen HAN Jun 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2016年第8期609-611,共3页
To understand the potential causes of laboratory-acquired infections and to provide possible solutions that would protect laboratory personnel, samples from a viral laboratory were screened to determine the main sourc... To understand the potential causes of laboratory-acquired infections and to provide possible solutions that would protect laboratory personnel, samples from a viral laboratory were screened to determine the main sources of contamination with six subtypes of Rhinovirus. Rhinovirus contamination was found in the gloves, cuffs of protective wear, inner surface of biological safety cabinet (BSC) windows, and trash handles. Remarkably, high contamination was found on the inner walls of the centrifuge and the inner surface of centrifuge tube casing in the rotor. Spilling infectious medium on the surface of centrifuge tubes was found to contribute to contamination of centrifuge surfaces. Exposure to sodium hypochlorite containing no less than 0.2 g/L available chlorine decontaminated the surface of the centrifuRe tubes from Rhinovirus after 2 min. 展开更多
关键词 Viral contamination Source in Clinical Microbiology Laboratory BSC HRV
暂未订购
Revolutionizing Hemodialysis Water Quality: Development and Evaluation of TiO₂ Nanoparticle-Enhanced Microporous Filters
3
作者 Opeyemi Temilade Enang Bakiyat Oluwagbemisola Azeez +3 位作者 Babatunde Temitope Ogunyemi Aminah Abolore Sulayman Dauda Olurotimi Araromi Morufu Olalekan Raimi 《Advances in Nanoparticles》 2025年第1期12-36,共25页
Rationale: Endotoxin contamination in conventionally purified water poses serious risks to hemodialysis patients, leading to complications such as inflammation and sepsis. Addressing these risks is essential for enhan... Rationale: Endotoxin contamination in conventionally purified water poses serious risks to hemodialysis patients, leading to complications such as inflammation and sepsis. Addressing these risks is essential for enhancing patient safety and meeting global dialysis water quality standards. Advanced filtration technologies, such as titanium dioxide (TiO₂)-based nanoparticle filters, offer a promising approach to improve water purification processes in renal care. Objectives: This study aimed to develop and evaluate the effectiveness of a TiO₂-based nanoparticle microporous filtration system for hemodialysis water purification. The objectives included analyzing the system’s performance in reducing chemical contaminants (calcium, magnesium, aluminum, and lead) and microbiological contaminants (total viable count [TVC] and endotoxin units [EU]) across multiple renal centers. Methods: Water samples from three renal centers (RC1, RC2, and RC3) were analyzed pre- and post-filtration. TiO₂ nanoparticles were synthesized using the sol-gel method and characterized via Fourier Transform Infrared (FTIR) spectroscopy and Scanning Electron Microscopy with Energy Dispersive X-ray analysis (SEM/EDX). The microporous filter, fabricated with TiO₂ nanoparticles, silicon dioxide, and polyethylene glycol (PEG), was tested for its ability to remove contaminants. Analytical techniques included spectroscopy for chemical analysis and microbiological assays for contaminant quantification. Results: Post-treatment analysis revealed significant reductions in chemical contaminants, with removal efficiencies averaging 78% for calcium, 80% for magnesium, 81% for aluminum, and 76.6% for lead across all centers. Microbiological contamination was also substantially reduced, with 78–80% removal of TVC and 76–84.6% reduction in EU levels. FTIR analysis confirmed the presence of hydroxyl groups critical for adsorption, while SEM/EDX characterization revealed a crystalline structure with a particle size of 1.45 nm, pore size of 4.11 μm, filter height of 2.56 mm, and bulk density of 0.58 g/cm³. Conclusion: The TiO₂-based nanoparticle filtration system demonstrated high efficacy in removing chemical and microbiological contaminants, significantly improving water quality for hemodialysis. These results highlight its potential as a practical solution for renal centers, especially in resource-constrained settings. Further studies are needed to evaluate its long-term performance and feasibility for widespread adoption. Recommendation: Renal centers should consider adopting TiO2-based nanoparticle filters to address persistent water quality challenges. Pilot implementations across diverse settings can provide insights into operational feasibility. Additional research should explore scalability, maintenance requirements, and cost-effectiveness to optimize integration into healthcare systems. Significance Statement: This study introduces a practical and innovative solution to improve hemodialysis water purification. By effectively reducing both chemical and microbiological contaminants, the TiO2-based filtration system has the potential to enhance patient safety and outcomes, particularly in settings where maintaining high water quality standards remains challenging. 展开更多
关键词 TiO2 Nanoparticles HEMODIALYSIS Water Purification Endotoxin contamination Photocatalytic Filtration Nanotechnology Microporous Filter Sol-Gel Synthesis microbiological Contaminants Environmental Remediation
在线阅读 下载PDF
Seasonal and Spatial Variation in the Monitoring Parameters of Zomar Stream, Palestine during 2010
4
作者 Saleh Sulaiman Laura Scrano +1 位作者 Sabino Aurelio Bufo Rafik Karaman 《Journal of Environmental Science and Engineering(A)》 2013年第1期1-14,共14页
Levels of pollutants at Zomar stream, the only recreational area for the inhabitants of the northern part of the West Bank, Palestine, were recently determined, and have shown to be relatively high. Three bathing site... Levels of pollutants at Zomar stream, the only recreational area for the inhabitants of the northern part of the West Bank, Palestine, were recently determined, and have shown to be relatively high. Three bathing sites along the Zomar stream area were monitored for one year (fortnightly). Wastewater samples were subjected to microbiological analysis (fecal coliforms, Escherichia coli, Pseudomonas, Enterococcus and Klebsiella), physico-chemical analyses (water temperature, pH, electroconductivity and DO (dissolved oxygen)), biochemical oxygen demand, total Kjeldahl nitrogen and ammonia. The study results demonstrated seasonal and locational variations in all parameters studied. The highest levels of pollution were detected during summer, especially before a rainfall or after a discharge from onsite cesspits. Locations associated with sewage discharge were found to have the highest fecal indicator levels. 展开更多
关键词 Wastewater pollution seasonal variations Zomar stream microbiological contamination BOD (biochemical oxygen demand).
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部