Air-sea water vapor and CO_(2) flux observation experiments were carried out at the Yantai National Satellite Ocean Calibration Platform and the jetty at Monolithic Beach,Juehua Island,using a 100 Hz gas analyzer.The ...Air-sea water vapor and CO_(2) flux observation experiments were carried out at the Yantai National Satellite Ocean Calibration Platform and the jetty at Monolithic Beach,Juehua Island,using a 100 Hz gas analyzer.The observations were corrected by employing wild point rejection,linear detrending,delay correction,coordinate rotation,time matching,and Webb,Pearman,and Leuning(WPL)correction.The results of spectral analysis and a turbulence development adequacy data quality check showed that the overall observation data quality was good.The air-sea water vapor and CO_(2) flux results showed that the observation duration affected both the air-sea flux intensity and direction at different observation frequencies.At shorter observation durations,the air-sea flux values measured at 100 Hz were smaller than the 20 Hz measurements and had opposite directions.In addition,the WPL correction reduced the overall air-sea flux and partially minimized the effect of observation frequency on the air-sea flux intensity.These results showed that high-frequency observations showed more turbulence variations than low-frequency observations.This conclusion could promote an understanding of small-scale turbulence variations.展开更多
In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (...In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (5%),was used for data processing and could solve the problem caused by the phenomenon of substrate depleting occurred following the redox reaction in portable blood sugar analyzer.By contrast to the conventional end-point method,the dynamic linear detecting method is based on multipoint data collecting.Experiments of measuring the calibration glucose solution with 8 various concentrations from 50 mg/dl to 400 mg/dl were carried out with the analyzer developed by our group.The linear regression curve,whose correlation for the data was 0.9995 and the residual was 2.8080,were obtained.The obtained correlation,residual, and the computation workload are all fit for the portable blood sugar analyzer.展开更多
Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system ...Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system with electromagnetic system will cause EMR malfunction. The nonlinear dynamics model of armature systems was studied by considering electro- magnetic attraction force and opposite mechanical force in this paper. Angular displacements of armature under different sinu- soidal vibration conditions are solved in order to obtain the failure mode result from armature system. Vibration tests showed the presented analyzing method is suitable for EMR. The conclusions are instructive for increasing vibration resistance of armature systems of EMR, and are significant for reliability design of switch apparatus.展开更多
This study focused on the performance of where elements analysing techniques were used to detect the elements in granite stones. These techniques are NAA (neutron activation analysis) and XRF (X-ray fluorescence)....This study focused on the performance of where elements analysing techniques were used to detect the elements in granite stones. These techniques are NAA (neutron activation analysis) and XRF (X-ray fluorescence). They were applied to detect the elements in samples which had been chosen from different areas of Pulua Penang in Malaysia collected by geophysics group which helped to describe and identify the elements found in the granite stone that were used in the study procedures to control the analytical results. The integration of both methods has enabled the researcher to determine 40 elements in the samples. The numbers of elements detected by XRF analysis method are 12 elements (Ar, K, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn); while, the elements detected by NAA method have three folds of elements with XRF analysis method were 35 elements (Na, AI, Si, K, Ca, Sc,Ti, Mn, Fe, Co, Ga, Ce, As, Br, Rb, Zr, Sb, I, Cs, Ba, La, Nd, Sm, Eu,Tb, Dy, Yb, Lu, Hf, Ta, W, Au, Pa and Np). Seven common elements were detected in both techniques: K, Sc, Ti, V, Mn, Fe and Co. Si has a higher concentration in NAA technique which is 331.8 ppm. Sc has a lower concentration in XRF technique which is 0.25 ppm. Nd has a lower concentration in NAA technique which is 3.09 - 10-5 ppm. Finally, it is found that the NAA is better to detect the elements than XRF.展开更多
Background:Lipemia,characterized by elevated triglyceride levels in blood samples,is a prevalent preanalytical interferent in clinical hematology.It leads to erroneous measurements of key complete blood count(CBC)para...Background:Lipemia,characterized by elevated triglyceride levels in blood samples,is a prevalent preanalytical interferent in clinical hematology.It leads to erroneous measurements of key complete blood count(CBC)parameters,including falsely elevated hemoglobin(Hgb)and platelet(PLT)counts.These inaccuracies can compromise diagnostic reliability and patient management.Objective:This review systematically evaluates existing correction methods for lipemic interference in CBC analysis,comparing their efficacy,limitations,and applicability in clinical settings.Methods:We analyze saline replacement,formula-based correction,instrument-specific algorithms,and emerging technologies,supported by experimental and clinical validation data.Conclusion:An optimized,context-dependent strategy is proposed,integrating multiple correction approaches based on lipemia severity.Future research directions,including artificial intelligence(AI)-enhanced corrections and standardized protocols,are discussed to advance hematology testing accuracy.展开更多
基金The National Key Research and Development Program of China under contract Nos 2022YFC3104203 and 2018YFC0213103the Science Foundation of Donghai Laboratory under contract No.DH-2022KF01019+1 种基金the National Natural Science Foundation under contract No.419061522023 Shanghai Education Science Research Project under contract No.C2023120.
文摘Air-sea water vapor and CO_(2) flux observation experiments were carried out at the Yantai National Satellite Ocean Calibration Platform and the jetty at Monolithic Beach,Juehua Island,using a 100 Hz gas analyzer.The observations were corrected by employing wild point rejection,linear detrending,delay correction,coordinate rotation,time matching,and Webb,Pearman,and Leuning(WPL)correction.The results of spectral analysis and a turbulence development adequacy data quality check showed that the overall observation data quality was good.The air-sea water vapor and CO_(2) flux results showed that the observation duration affected both the air-sea flux intensity and direction at different observation frequencies.At shorter observation durations,the air-sea flux values measured at 100 Hz were smaller than the 20 Hz measurements and had opposite directions.In addition,the WPL correction reduced the overall air-sea flux and partially minimized the effect of observation frequency on the air-sea flux intensity.These results showed that high-frequency observations showed more turbulence variations than low-frequency observations.This conclusion could promote an understanding of small-scale turbulence variations.
文摘In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (5%),was used for data processing and could solve the problem caused by the phenomenon of substrate depleting occurred following the redox reaction in portable blood sugar analyzer.By contrast to the conventional end-point method,the dynamic linear detecting method is based on multipoint data collecting.Experiments of measuring the calibration glucose solution with 8 various concentrations from 50 mg/dl to 400 mg/dl were carried out with the analyzer developed by our group.The linear regression curve,whose correlation for the data was 0.9995 and the residual was 2.8080,were obtained.The obtained correlation,residual, and the computation workload are all fit for the portable blood sugar analyzer.
基金Project (No. FEBQ24409102) supported by the Space Technology Innovation Fund, China
文摘Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system with electromagnetic system will cause EMR malfunction. The nonlinear dynamics model of armature systems was studied by considering electro- magnetic attraction force and opposite mechanical force in this paper. Angular displacements of armature under different sinu- soidal vibration conditions are solved in order to obtain the failure mode result from armature system. Vibration tests showed the presented analyzing method is suitable for EMR. The conclusions are instructive for increasing vibration resistance of armature systems of EMR, and are significant for reliability design of switch apparatus.
文摘This study focused on the performance of where elements analysing techniques were used to detect the elements in granite stones. These techniques are NAA (neutron activation analysis) and XRF (X-ray fluorescence). They were applied to detect the elements in samples which had been chosen from different areas of Pulua Penang in Malaysia collected by geophysics group which helped to describe and identify the elements found in the granite stone that were used in the study procedures to control the analytical results. The integration of both methods has enabled the researcher to determine 40 elements in the samples. The numbers of elements detected by XRF analysis method are 12 elements (Ar, K, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn); while, the elements detected by NAA method have three folds of elements with XRF analysis method were 35 elements (Na, AI, Si, K, Ca, Sc,Ti, Mn, Fe, Co, Ga, Ce, As, Br, Rb, Zr, Sb, I, Cs, Ba, La, Nd, Sm, Eu,Tb, Dy, Yb, Lu, Hf, Ta, W, Au, Pa and Np). Seven common elements were detected in both techniques: K, Sc, Ti, V, Mn, Fe and Co. Si has a higher concentration in NAA technique which is 331.8 ppm. Sc has a lower concentration in XRF technique which is 0.25 ppm. Nd has a lower concentration in NAA technique which is 3.09 - 10-5 ppm. Finally, it is found that the NAA is better to detect the elements than XRF.
文摘Background:Lipemia,characterized by elevated triglyceride levels in blood samples,is a prevalent preanalytical interferent in clinical hematology.It leads to erroneous measurements of key complete blood count(CBC)parameters,including falsely elevated hemoglobin(Hgb)and platelet(PLT)counts.These inaccuracies can compromise diagnostic reliability and patient management.Objective:This review systematically evaluates existing correction methods for lipemic interference in CBC analysis,comparing their efficacy,limitations,and applicability in clinical settings.Methods:We analyze saline replacement,formula-based correction,instrument-specific algorithms,and emerging technologies,supported by experimental and clinical validation data.Conclusion:An optimized,context-dependent strategy is proposed,integrating multiple correction approaches based on lipemia severity.Future research directions,including artificial intelligence(AI)-enhanced corrections and standardized protocols,are discussed to advance hematology testing accuracy.