A method for the optimal fiber input power determination is presented by employing the variation characteristics of signal to noise ratio(SNR) in spontaneous Brillouin-scattering-based sensing system. And a heterodyne...A method for the optimal fiber input power determination is presented by employing the variation characteristics of signal to noise ratio(SNR) in spontaneous Brillouin-scattering-based sensing system. And a heterodyne detection system is constructed for measuring the Brillouin scattering spectra with different fiber input powers. The Brillouin spectrum width and system SNR can be simultaneously measured from these spectra, and the optimal fiber input power can be obtained from such information. In the experiment, for 48.8-km-long standard single-mode fiber(SSMF), the optimal fiber input power values are all approximately 0 dBm obtained by the maximum SNR position for different local oscillator power values and average times.展开更多
A fluoroimmunoassay method using unlabeled europium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simple because labeling process...A fluoroimmunoassay method using unlabeled europium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simple because labeling process is omitted.The detection limit is about 10^(10) mol/L antigen.The relative standard deviation of immunoassay is less than 10%.The recoveries of human serum albumin and estradiol protein conjugate are 96-105% and 111% respectively.展开更多
A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process ...A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process is unnecessary.The recovery of HSA and albumin in urine is 107% and 95% respectively.The standard deviation is tess than 10%.展开更多
基金supported by the National Natural Science Foundation of China(No.61377088)the Natural Science Foundation of Hebei Province of China(Nos.E2015502053 and F2014502098)
文摘A method for the optimal fiber input power determination is presented by employing the variation characteristics of signal to noise ratio(SNR) in spontaneous Brillouin-scattering-based sensing system. And a heterodyne detection system is constructed for measuring the Brillouin scattering spectra with different fiber input powers. The Brillouin spectrum width and system SNR can be simultaneously measured from these spectra, and the optimal fiber input power can be obtained from such information. In the experiment, for 48.8-km-long standard single-mode fiber(SSMF), the optimal fiber input power values are all approximately 0 dBm obtained by the maximum SNR position for different local oscillator power values and average times.
基金This work was supported by National Natural Science Foundation of China.
文摘A fluoroimmunoassay method using unlabeled europium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simple because labeling process is omitted.The detection limit is about 10^(10) mol/L antigen.The relative standard deviation of immunoassay is less than 10%.The recoveries of human serum albumin and estradiol protein conjugate are 96-105% and 111% respectively.
基金supported by National Commission of Natural Science Foundation of China.
文摘A fluoroimmunoassay method using unlabeled Terbium chelate is described.The principle is similar to that of fluoroimmunoassay method using lanthanide chelate as labels.The procedure is simpte because labeling process is unnecessary.The recovery of HSA and albumin in urine is 107% and 95% respectively.The standard deviation is tess than 10%.