CFD modeling of methane distribution at a continuous miner face with various curtain setback distances 被引量:11
1
作者 Zhou Lihong Pritchard Christopher Zheng Yi 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2015年第4期635-640,共6页
Knowledge of the airflow patterns and methane distributions at a continuous miner face under different ventilation conditions can minimize the risks of explosion and injury to miners by accurately forecasting potentia... Knowledge of the airflow patterns and methane distributions at a continuous miner face under different ventilation conditions can minimize the risks of explosion and injury to miners by accurately forecasting potentially hazardous face methane levels. This study focused on validating a series of computational fluid dynamics(CFD) models using full-scale ventilation gallery data that assessed how curtain setback distance impacted airflow patterns and methane distributions at an empty mining face(no continuous miner present). Three CFD models of face ventilation with 4.6, 7.6 and 10.7 m(15, 25, and 35 ft) blowing curtain setback distances were constructed and validated with experimental data collected in a full-scale ventilation test facility. Good agreement was obtained between the CFD simulation results and this data.Detailed airflow and methane distribution information are provided. Elevated methane zones at the working faces were identified with the three curtain setback distances. Visualization of the setback distance impact on the face methane distribution was performed by utilizing the post-processing capability of the CFD software. 展开更多
关键词 Mine ventilation Computational fluid dynamics Continuous mining face Airflow pattern methane distribution
在线阅读 下载PDF
Numerical Simulation of Methane Distribution and Sensor Placement in 2-Dimension Roadway 被引量:5
2
作者 SUN Ji-ping TANG Liang CHEN Wei WANG Fu-zeng 《Journal of China University of Mining and Technology》 EI 2007年第3期372-375,共4页
In order to provide a theoretical basis for methane sensor placement in the vertical direction of a tunnel,the software Fluent was used to simulate methane distribution. A geometric roadway model was established and d... In order to provide a theoretical basis for methane sensor placement in the vertical direction of a tunnel,the software Fluent was used to simulate methane distribution. A geometric roadway model was established and divided by grids. Methane distribution in both level and vertical sections was simulated using a realizable k-ε model with the Fluent software according to a conservation equation in a turbulent state,a turbulent kinetic energy equation and a turbulent dissipation rate equation. The realizable k-ε model and the Fluent software were used to simulate methane distribution according to the principle of the conservation equation in a state of turbulent flow. The results show that after overflow-ing,a methane level with a certain thickness is formed. Methane density curves at three specific levels were internally consistent and methane density at higher levels is denser than that at lower levels. Methane distribution becomes thinner in the direction of wind and methane in the vertical direction becomes uniform if wind speed is high. The distance be-tween sensors and roof should be less than 300 mm which is in agreement with mine safety regulations. 展开更多
关键词 numerical simulation methane sensor placement methane distribution realizable k-ε model
在线阅读 下载PDF
Research on the hazards of gas leakage and explosion in a full-scale residential building
3
作者 Chengjun Yue Li Chen +2 位作者 Zhan Li Bin Feng Ruizhi Xu 《Defence Technology(防务技术)》 2025年第1期168-181,共14页
The gas explosion in residential building has always been a highly concerned problem.Explosions in homogeneous mixtures have been extensively studied.However,mixtures are often inhomogeneous in the practical scenarios... The gas explosion in residential building has always been a highly concerned problem.Explosions in homogeneous mixtures have been extensively studied.However,mixtures are often inhomogeneous in the practical scenarios due to the differences in the densities of methane and air.In order to investigate the effects of gas explosions in inhomogeneous mixtures,experimental studies involving gas leakage and explosion are conducted in a full-scale residential building to reproduce the process of gas explosion.By fitting the dimensionless buoyancy as a function of dimensionless height and dimensionless time,a distribution model of gas in large-scale spaces is established,and the mechanism of inhomogeneous distribution of methane is also be revealed.Furthermore,the stratified reconstruction method(SRM)is introduced for efficiently setting up inhomogeneous concentration fields in FLACS.The simulation results highlight that for the internal overpressure,the distribution of methane has no effect on the first overpressure peak(ΔP1),while it significantly influences the subsequent overpressure peak(ΔP2),and the maximum difference between the overpressure of homogeneous and inhomogeneous distribution is174.3%.Moreover,the initial concentration distribution also has a certain impact on the external overpressure. 展开更多
关键词 methane distribution Inhomogeneous mixture Gradient layer Gas explosion Explosive simulation
在线阅读 下载PDF