期刊文献+
共找到27篇文章
< 1 2 >
每页显示 20 50 100
Method of Predicting Water Content in Crude Oil Based on Measuring Range Automatic Switching
1
作者 陈祥光 朱文博 +1 位作者 赵军 任磊 《Journal of Beijing Institute of Technology》 EI CAS 2010年第1期87-91,共5页
Water content in output crude oil is hard to measure precisely because of wide range of dielectric coefficient of crude oil caused by injected dehydrating and demulsifying agents.The method to reduce measurement error... Water content in output crude oil is hard to measure precisely because of wide range of dielectric coefficient of crude oil caused by injected dehydrating and demulsifying agents.The method to reduce measurement error of water content in crude oil proposed in this paper is based on switching measuring ranges of on-line water content analyzer automatically.Measuring precision on data collected from oil field and analyzed by in-field operators can be impressively improved by using back propogation (BP) neural network to predict water content in output crude oil.Application results show that the difficulty in accurately measuring water-oil content ratio can be solved effectively through this combination of on-line measuring range automatic switching and real time prediction,as this method has been tested repeatedly on-site in oil fields with satisfactory prediction results. 展开更多
关键词 water content in crude oil prediction method BP network measuring range automatic switching
在线阅读 下载PDF
Combining Cubic Spline Interpolation and Fast Fourier Transform to Extend Measuring Range of Reflectometry
2
作者 Ju Cheng Jian Lu +7 位作者 Hong-Chao Zhang Feng Lei Maryam Sardar Xin-Tian Bian Fen Zuo Zhong-Hua Shen Xiao-Wu Ni Jin Shi 《Chinese Physics Letters》 SCIE CAS CSCD 2018年第5期20-24,共5页
The reflectometry is a common method used to measure the thickness of thin films. Using a conventional method,its measurable range is limited due to the low resolution of the current spectrometer embedded in the refle... The reflectometry is a common method used to measure the thickness of thin films. Using a conventional method,its measurable range is limited due to the low resolution of the current spectrometer embedded in the reflectometer.We present a simple method, using cubic spline interpolation to resample the spectrum with a high resolution,to extend the measurable transparent film thickness. A large measuring range up to 385 m in optical thickness is achieved with the commonly used system. The numerical calculation and experimental results demonstrate that using the FFT method combined with cubic spline interpolation resampling in reflectrometry, a simple,easy-to-operate, economic measuring system can be achieved with high measuring accuracy and replicability. 展开更多
关键词 FIGURE FFT Combining Cubic Spline Interpolation and Fast Fourier Transform to Extend measuring range of Reflectometry
原文传递
An ultra-sensitive and wide measuring range pressure sensor with paper-based CNT film/interdigitated structure 被引量:6
3
作者 Chao Wang Xiaojuan Hou +7 位作者 Min Cui Junbin Yu Xueming Fan Jichao Qian Jian He Wenping Geng Jiliang Mu Xiujian Chou 《Science China Materials》 SCIE EI CSCD 2020年第3期403-412,共10页
Flexible pressure sensors have attracted great attention due to their potential in the wearable devices market and in particular in human-machine interactive interfaces.Pressure sensors with high sensitivity,wide meas... Flexible pressure sensors have attracted great attention due to their potential in the wearable devices market and in particular in human-machine interactive interfaces.Pressure sensors with high sensitivity,wide measurement range,and low-cost are now highly desired for such practical applications.In the present investigation,an ultrasensitive pressure sensor with wide measurement range has been successfully fabricated.Carbon nanotubes(CNTs)(uniformly sprayed on the surface of paper)comprise the sensitivity material,while lithographed interdigital electrodes comprise the substrate.Due to the synergistic effects of CNT’s high specific surface area,paper’s porous structure,interdigital electrodes’efficient contact with CNT,our pressure sensor realizes a wide measurement range from 0 to 140 kPa and exhibits excellent stability through 15,000 cycles of testing.For the paper-based CNT film/interdigitated structure(PCI)pressure sensor,the connection area between the sensitive material and interdigital electrodes dominates in the lowpressure region,while internal change within the sensitive materials plays the leading role in the high-pressure region.Additionally,the PCI pressure sensor not only displays a high sensitivity of 2.72 kPa–1(up to 35 kPa)but also can detect low pressures,such as that exerted by a resting mung bean(about 8 Pa).When attached to the surface of a human body,the pressure sensor can monitor physiological signals,such as wrist movement,pulse beats,or movement of throat muscles.Furthermore,the pressure sensor array can identify the spatial pressure distribution,with promising applications in humanmachine interactive interfaces. 展开更多
关键词 carbon nanotube interdigital structure pressure sensors paper-based carbon nanotube(CNT)film ultrabroad measuring range
原文传递
A novel wide-range precision instrument for measuring three-dimensional surface topography
4
作者 杨旭东 《Journal of Chongqing University》 CAS 2008年第1期52-57,共6页
We developed a measuring instrument that had wide range, high precision, small measuring touch force. The instrument for three-dimensional (3D) surface topography measurement was composed of a high precision displacem... We developed a measuring instrument that had wide range, high precision, small measuring touch force. The instrument for three-dimensional (3D) surface topography measurement was composed of a high precision displacement sensor based on the Michelson interference principle, a 3D platform based on vertical scanning, a measuring and control circuit, and an industrial control computer. It was a closed loop control system, which changed the traditional moving stylus scanning style into a moving platform scanning style. When the workpiece was measured, the lever of the displacement sensor returned to the balanced position in every sample interval according to the zero offset of the displacement sensor. The non-linear error caused by the rotation of the lever was, therefore, very small even if the measuring range was wide. The instrument can measure the roughness and the profile size of a curved surface. 展开更多
关键词 instrument circuit surface topography measurement error wide range precision instrument displacement sensor 3D platform
在线阅读 下载PDF
Improving IAC Algorithm Based on Range Rate Measurement 被引量:1
5
作者 张鸿业 王月涌 蔡颖臻 《Journal of Beijing Institute of Technology》 EI CAS 1999年第3期276-281,共6页
Aim Interactive multiple model(IMM) algorithm was introduced into two? stage estimation to improve the estimating accuracy for system position and velocity.Methods The state estimation was carried out in mixed coor... Aim Interactive multiple model(IMM) algorithm was introduced into two? stage estimation to improve the estimating accuracy for system position and velocity.Methods The state estimation was carried out in mixed coordinates according to the nonlinear measure equation, a generalized interactive acceleration compensation(IAC) algorithm in mixed coordinate was presented. Results Simulation result shows the estimation accuracy is improved through changing measure equation in polar coordinates. Conclusion The estimation accuracy for position and velocity estimation, has been improved greatly, and the proposed algorithm has the advantage of less calculating time comparing with other multiple model methods. 展开更多
关键词 range rate measurement interactive acceleration compensation two-stage estimation
在线阅读 下载PDF
Highly sensitive digital optical sensor with large measurement range based on the dual-microring resonator with waveguide-coupled feedback 被引量:3
6
作者 向星烨 王葵如 +3 位作者 苑金辉 晋博源 桑新柱 余重秀 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第3期284-288,共5页
We propose a novel high-performance digital optical sensor based on the Mach-Zehnder interferential effect and the dual-microring resonators with the waveguide-coupled feedback. The simulation results show that the se... We propose a novel high-performance digital optical sensor based on the Mach-Zehnder interferential effect and the dual-microring resonators with the waveguide-coupled feedback. The simulation results show that the sensitivity of the sensor can be orders of magnitude higher than that of aconventional sensor, and high quality factor is not critical in it. Moreover, by optimizing the length of the feedback waveguide to be equal to the perimeter of the ring, the measurement range of the proposed sensor is twice as much as that of the conventional sensor in the weak coupling case. 展开更多
关键词 optical sensor microring resonator high sensitivity large measurement range
原文传递
Theoretical and experimental assessment of a novel method to establish the complete measurement range of the calorimeter and its limit of detection and quantification
7
作者 Vesna Krstic 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第4期466-473,共8页
For determining the accuracy of a calorimeter over the instrument’s entire measuring range,a novel method has been established.For this new approach,(a)benzoic acid(C_(6)H_(5)CO_(2)H) as a certified reference materia... For determining the accuracy of a calorimeter over the instrument’s entire measuring range,a novel method has been established.For this new approach,(a)benzoic acid(C_(6)H_(5)CO_(2)H) as a certified reference material(CRM),(b)SiO_(2) and(c)a mixture of CRM benzoic acid and SiO_(2) have been used.To illustrate the essential difference between 1)the novel analytical method for control of the entire measurement range and 2)the calorimeter calibration,both applications of benzoic acid(BA)have been demonstrated.An experimental result showed that BA was successfully used to check the whole calorimeter measurement range.The results also showed that the same new method was successfully applied to determine the limit of detection and quantification.A new instrument testing process and a new measurement technique have thus been established.In this way,the cost of using CRM to control the accuracy of measuring the entire measuring range of the calorimeter,as shown in this paper,is minimized.The requirements of the ISO/IEC 17025:2017 standard are satisfied.ISO/IEC 17025:2017,together with ISO 9001:2015(quality management systems),ISO 14001:2015(relate to environmental protection)and ISO45001:2018(occupational safety),constitute an integrated quality system by which a testing laboratory may also accredit. 展开更多
关键词 Benzoic acid Certified reference material The limit of detection/quantification Measurement range Quality control CALORIMETER Environmental protection
在线阅读 下载PDF
MLSI-RT: memorize LOS range measurements identified residual test location algorithm and performance analysis
8
作者 马兵 邢建平 张军 《Journal of Shanghai University(English Edition)》 CAS 2011年第3期190-193,共4页
The dominant error source of mobile terminal location in wireless sensor networks (WSNs) is the non-line-of-sight (NLOS) propagation error. Among the algorithms proposed to mitigate the influence of NLOS propagati... The dominant error source of mobile terminal location in wireless sensor networks (WSNs) is the non-line-of-sight (NLOS) propagation error. Among the algorithms proposed to mitigate the influence of NLOS propagation error, residual test (RT) is an efficient one, however with high computational complexity (CC). An improved algorithm that memorizes the light of sight (LOS) range measurements (RMs) identified memorize LOS range measurements identified residual test (MLSI-RT) is presented in this paper to address this problem. The MLSI-RT is based on the assumption that when all RMs are from LOS propagations, the normalized residual follows the central Chi-Square distribution while for NLOS cases it is non-central. This study can reduce the CC by more than 90%. 展开更多
关键词 memorize LOS range measurements identified residual test (MLSI-RT) computational complexity (CC) nonline-of-sight (NLOS) residual test (RT) algorithm simplified residual test (SRT)
在线阅读 下载PDF
Low-complexity multi-target localization via multi-BS sensing
9
作者 Yinxiao Zhuo Zhaocheng Wang 《Digital Communications and Networks》 2025年第4期1140-1148,共9页
Integrated Sensing and Communication(ISAC)is envisioned as a promising technology for Sixth-Generation(6G)wireless communications,which enables simultaneous high-rate communication and high-precision target localizati... Integrated Sensing and Communication(ISAC)is envisioned as a promising technology for Sixth-Generation(6G)wireless communications,which enables simultaneous high-rate communication and high-precision target localization.Compared to independent sensing and communication modules,dual-function ISAC could leverage the strengths of both communication and sensing in order to achieve cooperative gains.When considering the communication core network,ISAC system facilitates multiple communication devices to collaborate for networked sensing.This paper investigates such kind of cooperative ISAC systems with distributed transmitters and receivers to support non-connected and multi-target localization.Specifically,we introduce a Time of Arrival(TOA)based multi-target localization scheme,which leverages the bi-static range measurements between the transmitter,target,and receiver channels in order to achieve elliptical localization.To obtain the low-complexity localization,a two-stage search-refine localization methodology is proposed.In the first stage,we propose a Successive Greedy Grid-Search(SGGS)algorithm and a Successive-Cancellation-List Grid-Search(SCLGS)algorithm to address the Measurement-to-Target Association(MTA)problem with relatively low computational complexity.In the second stage,a linear approximation refinement algorithm is derived to facilitate high-precision localization.Simulation results are presented to validate the effectiveness and superiority of our proposed multi-target localization method. 展开更多
关键词 Integrated sensing and communication Multi-target localization Measurement-to-target association problem Bi-static range measurement Low complexity
在线阅读 下载PDF
A survey on sensor localization 被引量:17
10
作者 Jing WANG R. K. GHOSH Sajal K. DAS 《控制理论与应用(英文版)》 EI 2010年第1期2-11,共10页
Localization is one of the fundamental problems in wireless sensor networks (WSNs), since locations of the sensor nodes are critical to both network operations and most application level tasks. Although the GPS base... Localization is one of the fundamental problems in wireless sensor networks (WSNs), since locations of the sensor nodes are critical to both network operations and most application level tasks. Although the GPS based localization schemes can be used to determine node locations within a few meters, the cost of GPS devices and non-availability of GPS signals in confined environments prevent their use in large scale sensor networks. There exists an extensive body of research that aims at obtaining locations as well as spatial relations of nodes in WSNs without requiring specialized hardware and/or employing only a limited number of anchors that are aware of their own locations. In this paper, we present a comprehensive survey on sensor localization in WSNs covering motivations, problem formulations, solution approaches and performance summary. Future research issues will also be discussed. 展开更多
关键词 Sensor localization Wireless sensor networks range measurements ANCHORS Mobile sensor Proba-bilistic localization
在线阅读 下载PDF
Tracking method based on separation and combination of the measurements for radar and IR fusion system 被引量:6
11
作者 Wang Qingchao Wang Wenfei 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2009年第2期241-246,共6页
A new distributed fusion method of radar/infrared (IR) tracking system based on separation and combination of the measurements is proposed by analyzing the influence of rate measurement. The rate information separat... A new distributed fusion method of radar/infrared (IR) tracking system based on separation and combination of the measurements is proposed by analyzing the influence of rate measurement. The rate information separated from the radar measurements together with measurements of IR form a pseudo vector of IR, and the corresponding filter is designed. The results indicate that the method not only makes a great improvement to the local tracker's performance, but also improves the global tracking precision efficiently. 展开更多
关键词 information fusion target tracking range rate measurement extended Kalman filter
在线阅读 下载PDF
Deep Sea AUV Navigation Using Multiple Acoustic Beacons 被引量:2
12
作者 冀大雄 宋伟 +1 位作者 赵宏宇 刘健 《China Ocean Engineering》 SCIE EI CSCD 2016年第2期309-318,共10页
Navigation is a critical requirement for the operation of Autonomous Underwater Vehicles(AUVs).To estimate the vehicle position,we present an algorithm using an extended Kalman filter(EKF) to integrate dead-reckon... Navigation is a critical requirement for the operation of Autonomous Underwater Vehicles(AUVs).To estimate the vehicle position,we present an algorithm using an extended Kalman filter(EKF) to integrate dead-reckoning position with acoustic ranges from multiple beacons pre-deployed in the operating environment.Owing to high latency,variable sound speed multipath transmissions and unreliability in acoustic measurements,outlier recognition techniques are proposed as well.The navigation algorithm has been tested by the recorded data of deep sea AUV during field operations in a variety of environments.Our results show the improved performance over prior techniques based on position computation. 展开更多
关键词 deep sea AUV acoustic navigation range measurements multiple beacons outlier recognition
在线阅读 下载PDF
Feedforward Control for Wind Turbine Load Reduction with Pseudo-LIDAR Measurement 被引量:2
13
作者 Jie Bao Hong Yue +1 位作者 William E.Leithead Ji-Qiang Wang 《International Journal of Automation and computing》 EI CSCD 2018年第2期142-155,共14页
A gain-scheduled feedforward controller, based on pseudo-LIDAR (light detection and ranging) wind speed measurement, is designed to augment the baseline feedback controller for wind turbine's load reduction in abov... A gain-scheduled feedforward controller, based on pseudo-LIDAR (light detection and ranging) wind speed measurement, is designed to augment the baseline feedback controller for wind turbine's load reduction in above rated operation. The pseudo-LIDAR measurement data are generated from a commercial software- Bladed using a designed sampling strategy. The nonlinear wind turbine model has been simplified and linearised at a set of equilibrium operating points. The feedforward controller is firstly developed based on a linearised model at an above rated wind speed, and then expanded to the full above rated operational envelope by employing gain scheduling strategy. The combined feedforward and baseline feedback control is simulated on a 5MW industrial wind turbine model. Simulation studies demonstrate that the proposed control strategy can improve the rotor and tower load reduction performance for large wind turbines. 展开更多
关键词 Wind turbine control light detection and ranging (LIDAR) measurement feedforward control load reduction gainscheduling disturbance rejection.
原文传递
Measurement of Refractive Index Ranging from 1.42847 to 2.48272 at 1064 nm Using a Quasi-Common-Path Laser Feedback System 被引量:1
14
作者 徐玲 谈宜东 +1 位作者 张书练 孙利群 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第9期21-24,共4页
Wavelength 1064 nm is one of the most widely used laser wavelengths in industries and science. The high-precision measurement of the refractive index of optical materials at 1064 nm is significant for improving the op... Wavelength 1064 nm is one of the most widely used laser wavelengths in industries and science. The high-precision measurement of the refractive index of optical materials at 1064 nm is significant for improving the optical design. We study the direct measurement of refractive index at 1064nm of lasers, including cMcium fluoride (CaF2), fused silica and zinc selenide (ZnSe), whose refractive indices cover a large range from 1.42847 to 2.48272. The measurement system is built based on the quasi-common-path Nd:YAG laser feedback interferometry. The thickness can be measured simultaneously with the refractive index. The results demonstrate that the system has absolute uncertainties of ~10-5 and ~10-4 mm in refractive index and thickness measurement, respectively. 展开更多
关键词 In Measurement of Refractive Index Ranging from 1.42847 to 2.48272 at 1064 nm Using a Quasi-Common-Path Laser Feedback System AOM
原文传递
Multi-parameter identification of gratings measurement by Experimental Ray Tracing
15
作者 Li-Si Chen Zhong-Wen Hu +2 位作者 Hai-Jiao Jiang Hui-Min Kang Chen-Zhong Wang 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2021年第11期119-126,共8页
A simple method for measuring grating groove density as well as its position and orientation is proposed based on the idea of ERT(Experimental Ray Tracing).Conventional methods only measure grating groove density with... A simple method for measuring grating groove density as well as its position and orientation is proposed based on the idea of ERT(Experimental Ray Tracing).Conventional methods only measure grating groove density with accuracy limited by its rotary stage and goniometer.The method proposed in the paper utilizes linear guides which could be calibrated to much higher accuracy.It is applicable to gratings of arbitrary surface profile or mosaic of a group of various gratings.Various measurement error sources are simulated by the Monte Carlo method and the results show high accuracy capability of grating parameters identification.A verification testing is performed.The accuracy dependency on main configuration parameters is evaluated.A method to expand measurement range by double wavelength is also discussed. 展开更多
关键词 GRATING groove density position ORIENTATION measurement range
在线阅读 下载PDF
Fabrication of a Flexible Electric Skin Using a Bionic Cell and Study of Its Sensing Ability
16
作者 Yani Jiang Zhi Wang +4 位作者 Yuhang Chen Shien Lu Jiachen Wu Yixiang Bian Wenjia Chen 《Journal of Bionic Engineering》 SCIE EI CSCD 2022年第1期62-72,共11页
Imitating the structure and function of the Pacinian corpuscle in the human body,a Bionic Cell(BC)with a liquid core was designed and made with polyvinylidene fluoride(PVDF),and an Electronic Skin(ES)sensor was succes... Imitating the structure and function of the Pacinian corpuscle in the human body,a Bionic Cell(BC)with a liquid core was designed and made with polyvinylidene fluoride(PVDF),and an Electronic Skin(ES)sensor was successfully obtained by embedding the BCs into silicone rubber.The passive sensing ability of the ES for surface vibration pressure was measured.The results showed that the ES could detect waveform,frequency,amplitude and other parameters of the surface,and it exhibited not only a high sensitivity of 0.46563 fc/Pa,but also a large pressure measurement range of 0.6 Pa–6014 Pa.A falling real object impact experiment was carried out,and the results indicated that the ES output charge was linearly related to the falling height of the object and logarithmically related to the mass of the object.Then,a crawling insect experiment and human pulse experiment were performed to study the perception ability of the ES to irregular pressure.Due to its special structure,simple fabrication process,and high sensitivity wide measurement range,the ES fabricated in this paper is expected to be used as robot skin with tactile perception ability in the near future. 展开更多
关键词 Electronic skin(ES) Tactile sensor Bionic cell(BC) Sensitivity Pressure measurement range
在线阅读 下载PDF
Recent Development of Dielectric Elastomer Transducers and Potential Applications
17
作者 Seiki Chiba Mikio Waki 《Energy and Power Engineering》 CAS 2023年第2期105-126,共22页
Power generation using dielectric elastomer transducers is cheap, light, stackable, easy to install, and highly efficient. Also, since the dielectric elastomer transducer is an actuator developed into an artificial mu... Power generation using dielectric elastomer transducers is cheap, light, stackable, easy to install, and highly efficient. Also, since the dielectric elastomer transducer is an actuator developed into an artificial muscle, if the DE motor is further developed, it might be possibly be able to drive a vehicle. Efficient robot driving, various industrial machines and the use of dielectric elastomer sensors to optimize the driving may also help solve the above problems from the perspective of eco-driving. This paper describes the latest level of development of dielectric elastomers, their main problems and solutions to these problems, and their potential applications. The possibilities and concrete plans for building local global smart cities (including local generation power for local consumption), efficient transportation, and environmental monitoring systems utilizing dielectric elastomers are also discussed. 展开更多
关键词 High-Efficiency Power Generation Lightweight and High-Output Actuator Sensor with Wide Measurement range Flexible SWCNT Spray
在线阅读 下载PDF
Integrated Computer Aided Shoe-Making System
18
作者 ZHU Chuanxu LIU Yigong LIU Xiaochun 《Computer Aided Drafting,Design and Manufacturing》 1991年第1期63-72,6,共11页
Shoemaking is one of the areas where CAD/CAM application is rapidly increasing.This paper introduces an integrated computer aided shoemaking system including human foot measuring,last (wooden model)measuring,last CAD/... Shoemaking is one of the areas where CAD/CAM application is rapidly increasing.This paper introduces an integrated computer aided shoemaking system including human foot measuring,last (wooden model)measuring,last CAD/CAM and pattern CAD/CAM.The project was supported by the 7th national economical 5 year plan.High technologies,suh as digital image processing,pattern rcognition,advanced geometrical modeling and a series of sophisticated equipments and devices are ap- plied in this integrated system.Parts of the system have become commercial products. 展开更多
关键词 SHOE-MAKING Digital Photogrammetry Close range measuring Surface Modeling SKINNING Surface Trimming
在线阅读 下载PDF
Photonic-assisted approach for instantaneous microwave frequency measurement with tunable range by using Mach-Zehnder interferometers 被引量:5
19
作者 王大鹏 徐坤 +3 位作者 戴键 吴钟乐 纪越峰 林金桐 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第2期12-14,共3页
A novel photonic-assisted approach to microwave frequency measurement is proposed and experimentally demonstrated. The proposed scheme is based on the frequency-to-power mapping with different transmis- sion responses... A novel photonic-assisted approach to microwave frequency measurement is proposed and experimentally demonstrated. The proposed scheme is based on the frequency-to-power mapping with different transmis- sion responses. A polarizer is used in one output branch of a phase modulator to simultaneously implement phase modulation and intensity modulation. Owing to the complementary nature of the transmission re- sponses and the Mach-Zehnder interferometers (MZIs), this scheme theoretically provides high resolution and tunable measurement range. The measurement errors in the experimental results can be kept within 0.2 GHz over a freauencv ranee from 0.1 to 5.3 GHz. 展开更多
关键词 Photonic-assisted approach for instantaneous microwave frequency measurement with tunable range by using Mach-Zehnder interferometers ACF
原文传递
A Range Adjusted Measure of Super-Efficiency in Integer-Valued Data Envelopment Analysis with Undesirable Outputs 被引量:4
20
作者 Chunhua CHEN Haohua LIU +1 位作者 Lijun TANG Jianwei REN 《Journal of Systems Science and Information》 CSCD 2021年第4期378-398,共21页
DEA(data envelopment analysis) models can be divided into two groups: Radial DEA and non-radial DEA, and the latter has higher discriminatory power than the former. The range adjusted measure(RAM) is an effective and ... DEA(data envelopment analysis) models can be divided into two groups: Radial DEA and non-radial DEA, and the latter has higher discriminatory power than the former. The range adjusted measure(RAM) is an effective and widely used non-radial DEA approach. However, to the best of our knowledge, there is no literature on the integer-valued super-efficiency RAM-DEA model,especially when undesirable outputs are included. We first propose an integer-valued RAM-DEA mode with undesirable outputs and then extend this model to an integer-valued super-efficiency RAM-DEA model with undesirable outputs. Compared with other DEA models, the two novel models have many advantages: 1) They are non-oriented and non-radial DEA models, which enable decision makers to simultaneously and non-proportionally improve inputs and outputs;2) They can handle integer-valued variables and undesirable outputs, so the results obtained are more reliable;3) The results can be easily obtained as it is based on linear programming;4) The integer-valued super-efficiency RAM-DEA model with undesirable outputs can be used to accurately rank efficient DMUs. The proposed models are applied to evaluate the efficiency of China’s regional transportation systems(RTSs) considering the number of transport accidents(an undesirable output). The results help decision makers improve the performance of inefficient RTSs and analyze the strengths of efficient RTSs. 展开更多
关键词 DEA range adjusted measure(RAM) SUPER-EFFICIENCY undesirable outputs transport
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部