The machining process remains relevant for manufacturing high-quality and high-precision parts,which can be found in industries such as aerospace and aeronautical,with many produced by turning,drilling,and milling pro...The machining process remains relevant for manufacturing high-quality and high-precision parts,which can be found in industries such as aerospace and aeronautical,with many produced by turning,drilling,and milling processes.Monitoring and analyzing tool wear during these processes is crucial to assess the tool’s life and optimize the tool’s performance under study;as such,standards detail procedures to measure and assess tool wear for various tools.Measuring wear in machining tools can be time-consuming,as the process is usually manual,requiring human interaction and judgment.In the present work,an automated offline flank wear measurement algorithm was developed in Python.The algorithm measures the flank wear of coated end-mills and slot drills from Scanning Electron Microscopy(SEM)images,according to the ISO 8688 standard,following the same wear measurement procedure.SEM images acquired with different magnifications and tools with varying machining parameters were analyzed using the developed algorithm.The flank wear measurements were then compared to the manually obtained,achieving relative errors for the most common magnifications of around 2.5%.Higher magnifications were also tested,yielding a maximum relative error of 13.4%.The algorithm can measure batches of images quickly on an ordinary personal computer,analyzing and measuring a 10-image batch in around 30 s,a process that would require around 30 min when performed manually by a skilled operator.Therefore,it can be a reliable alternative to measuring flank wear on many tools from SEM images,with the possibility of being adjusted for other wear measurements on different kinds of tools and different image types,for example,on images obtained by optical microscopy.展开更多
The presence of residual stresses in materials or engineering structures can significantly influence their mechanical per-formance.Accurate measurement of residual stresses is of great importance to ensure their in-se...The presence of residual stresses in materials or engineering structures can significantly influence their mechanical per-formance.Accurate measurement of residual stresses is of great importance to ensure their in-service reliability.Although numerous instrumented indentation methods have been proposed to evaluate residual stresses,the majority of them require a stress-free reference sample as a comparison benchmark,thereby limiting their applicability in scenarios where obtaining stress-free reference samples is challenging.In this work,through a number of finite element simulations,it was found that the loading exponent of the loading load-depth curve and the recovered depth during unloading are insensitive to residual stresses.The loading curve of the stress-free specimen was virtually reconstructed using such stress-insensitive parameters extracted from the load-depth curves of the stressed state,thus eliminating the requirement for stress-free reference samples.The residual stress was then correlated with the fractional change in loading work between stressed and stress-free loading curves through dimensional analysis and finite element simulations.Based on this correlation,an instrumented sharp indentation method for measuring equibiaxial residual stress without requiring a stress-free specimen was established.Both numerical and experimental verifications were carried out to demonstrate the accuracy and reliability of the newly proposed method.The maximum relative error and absolute error in measured residual stresses are typically within±20%and±20 MPa,respectively.展开更多
Traditional automated guided vehicle(AGV)primarily relies on scheduling systems to manage warehouse locations and execute picking or placing tasks on fixedheight pallets.However,these conventional systems are illsuite...Traditional automated guided vehicle(AGV)primarily relies on scheduling systems to manage warehouse locations and execute picking or placing tasks on fixedheight pallets.However,these conventional systems are illsuited for scenarios involving variable heights,such as vehicle loading and unloading or the complex stacking of soft packages.To address the challenges of AGV endeffector operations in nonfixed height scenarios,this paper proposes an innovative solution leveraging lowcost depth camera sensors.By capturing image and depth data,and integrating deep learning,image processing,and spatial attitude calculation techniques,the method accurately determines the position of the endeffector center point relative to the upper plane of the fork.The approach effectively resolves a key issue in AGV operations within intelligent logistics scenarios that lack fixed heights.The proposed algorithm is deployed on a domestic embedded,lowcost ARM chip controller,and extensive experiments are conducted on a real AGV equipped with multiple stacked vehicles and nonstandard vehicles.The experimental results demonstrate that for diverse vehicles with different heights,the measurement error can be maintained within±10 mm,satisfying the requirements for highprecision measurement.The height measurement method developed in the paper not only enhances the AGV’s adaptability in nonfixed height scenarios but also significantly broadens its application potential across various industries.展开更多
Rapid technological advancements drive miniaturization and high energy density in devices,thereby increasing nanoscale thermal management demands and urging development of higher spatial resolution technologies for th...Rapid technological advancements drive miniaturization and high energy density in devices,thereby increasing nanoscale thermal management demands and urging development of higher spatial resolution technologies for thermal imaging and transport research.Here,we introduce an approach to measure nanoscale thermal resistance using in situ inelastic scanning transmission electron microscopy.By constructing unidirectional heating flux with controlled temperature gradients and analyzing electron energy-loss/gain signals under optimized acquisition conditions,nanometer-resolution in mapping phonon apparent temperature is achieved.Thus,interfacial thermal resistance is determined by calculating the ratio of interfacial temperature difference to bulk temperature gradient.This methodology enables direct measurement of thermal transport properties for atomic-scale structural features(e.g.,defects and heterointerfaces),resolving critical structure-performance relationships,providing a useful tool for investigating thermal phenomena at the(sub-)nanoscale.展开更多
Crop water stress index(CWSI)is widely used for efficient irrigation management.Precise canopy temperature(T_(c))measurement is necessary to derive a reliable CWSI.The objective of this research was to investigate the...Crop water stress index(CWSI)is widely used for efficient irrigation management.Precise canopy temperature(T_(c))measurement is necessary to derive a reliable CWSI.The objective of this research was to investigate the influences of atmospheric conditions,settled height,view angle of infrared thermography,and investigating time of temperature measuring on the performance of the CWSI.Three irrigation treatments were used to create different soil water conditions during the 2020-2021 and 2021-2022 winter wheat-growing seasons.The CWSI was calculated using the CWSI-E(an empirical approach)and CWSI-T(a theoretical approach)based on the T_(c).Weather conditions were recorded continuously throughout the experimental period.The results showed that atmospheric conditions influenced the estimation of the CWSI;when the vapor pressure deficit(VPD)was>2000 Pa,the estimated CWSI was related to soil water conditions.The height of the installed infrared thermograph influenced the T_(c)values,and the differences among the T_(c)values measured at height of 3,5,and 10 m was smaller in the afternoon than in the morning.However,the lens of the thermometer facing south recorded a higher T_(c)than those facing east or north,especially at a low height,indicating that the direction of the thermometer had a significant influence on T_(c).There was a large variation in CWSI derived at different times of the day,and the midday measurements(12:00-15:00)were the most reliable for estimating CWSI.Negative linear relationships were found between the transpiration rate and CWSI-E(R^(2)of 0.3646-0.5725)and CWSI-T(R^(2)of 0.5407-0.7213).The relations between fraction of available soil water(FASW)with CWSI-T was higher than that with CWSI-E,indicating CWSI-T was more accurate for predicting crop water status.In addition,The R^(2)between CWSI-T and FASW at 14:00 was higher than that at other times,indicating that 14:00 was the optimal time for using the CWSI for crop water status monitoring.Relative higher yield of winter wheat was obtained with average seasonal values of CWSI-E and CWSI-T around 0.23 and 0.25-0.26,respectively.The CWSI-E values were more easily influenced by meteorological factors and the timing of the measurements,and using the theoretical approach to derive the CWSI was recommended for precise irrigation water management.展开更多
Geometric error,mainly due to imperfect geometry and dimensions of machine components,is one of the major error sources of machine tools.Considering that geometric error has significant effects on the machining qualit...Geometric error,mainly due to imperfect geometry and dimensions of machine components,is one of the major error sources of machine tools.Considering that geometric error has significant effects on the machining quality of manufactured parts,it has been a popular topic for academic and industrial research for many years.A great deal of research work has been carried out since the 1970s for solving the problem and improving the machining accuracy.Researchers have studied how to measure,detect,model,identify,reduce,and compensate the geometric errors.This paper presents a thorough review of the latest research activities and gives an overview of the state of the art in understanding changes in machine tool performance due to geometric errors.Recent advances in measuring the geometrical errors of machine tools are summarized,and different kinds of error identification methods of translational axes and rotation axes are illustrated respectively.Besides,volumetric geometric error modeling,tracing,and compensation techniques for five-axis machine tools are emphatically introduced.Finally,research challenges in order to improve the volumetric accuracy of machine tools are also highlighted.展开更多
The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(R...The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters.展开更多
Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted ...Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted into phase signals,it is interesting and important to consider measuring small longitudinal phase shifts by using weak measurement.Here,we propose and experimentally demonstrate a novel weak measurement amplification-based small longitudinal phase estimation,which is suitable for polarization interferometry.We realize one order of magnitude amplification measurement of a small phase signal directly introduced by a liquid crystal variable retarder and show that it is robust to the imperfection of interference.Besides,we analyze the effect of magnification error which is never considered in the previous works,and find the constraint on the magnification.Our results may find important applications in high-precision measurements,e.g.,gravitational wave detection.展开更多
The research on gas-liquid multiphase reactions using micro reactors is becoming increasingly widespread, given their excellent mass transfer performance. Establishing an accurate and reliable method to measure the ga...The research on gas-liquid multiphase reactions using micro reactors is becoming increasingly widespread, given their excellent mass transfer performance. Establishing an accurate and reliable method to measure the gas-liquid mass transfer performance of micro reactors is crucial for evaluating and optimizing the design of micro reactor structure. In this paper, the physical absorption method of aqueous solution-CO_(2) and the chemical absorption method of sodium carbonate solution-CO_(2) were proposed. By analyzing the chemical reaction equilibrium during the absorption process, the relationship between the mass transfer of CO_(2) and the solubility of hydroxide ions in the solution was established, and the total gas-liquid mass transfer coefficient was immediately obtained by measuring the p H value. The corresponding testing platform and process have been established based on the characteristics of the proposed method to ensure fast and accurate measurement. In addition, the chemical absorption method takes into account temperature factors that were not previously considered. The volumetric mass transfer coefficient measured by these two methods is in the same range as those measured by other methods using the same microchannel structure in previous literature. The methods have the advantages of low equipment cost, faster measurement speed, and simpler procedures, which can facilitate its wide application to the evaluation of the mass transfer performance and hence can guide the structure optimization of microchannel reactors.展开更多
BACKGROUND To avoid acute variceal bleeding in cirrhosis,current guidelines recommend screening for high-risk esophageal varices(EVs)by determining variceal size and identifying red wale markings.However,visual measur...BACKGROUND To avoid acute variceal bleeding in cirrhosis,current guidelines recommend screening for high-risk esophageal varices(EVs)by determining variceal size and identifying red wale markings.However,visual measurements of EV during routine endoscopy are often inaccurate.AIM To determine whether biopsy forceps(BF)could be used as a reference to improve the accuracy of binary classification of variceal size.METHODS An in vitro self-made EV model with sizes ranging from 2 to 12 mm in diameter was constructed.An online image-based survey comprising 11 endoscopic images of simulated EV without BF and 11 endoscopic images of EV with BF was assembled and sent to 84 endoscopists.The endoscopists were blinded to the actual EV size and evaluated the 22 images in random order.RESULTS The respondents included 48 academic and four private endoscopists.The accuracy of EV size estimation was low in both the visual(13.81%)and BF-based(20.28%)groups.The use of open forceps improved the ability of the endoscopists to correctly classify the varices by size(small≤5 mm,large>5 mm)from 71.85%to 82.17%(P<0.001).CONCLUSION BF may improve the accuracy of EV size assessment,and its use in clinical practice should be investigated.展开更多
The analysis and calculating method of dynamic errors of CMMs during probing are discussed.To relate the dynamic displacement errors with the dynamic rotational errors a method for obtaining the displacement errors at...The analysis and calculating method of dynamic errors of CMMs during probing are discussed.To relate the dynamic displacement errors with the dynamic rotational errors a method for obtaining the displacement errors at the probing position from dynamic rotational errors is presented.It is pointed out that the finite element method might be used for modeling dynamic errors.However,dynamic errors are difficult to be modeled so a combined practical and theoretical approach is needed.In addition,the dynamic errors are measured with inductive position sensors.展开更多
Dual-frequency and multi-polarization spaceborne rain and cloud measuring radar is the inevitable trend of remote sensing techniques.Techniques of new generation dual-frequency and multi-polarization spaceborne rain a...Dual-frequency and multi-polarization spaceborne rain and cloud measuring radar is the inevitable trend of remote sensing techniques.Techniques of new generation dual-frequency and multi-polarization spaceborne rain and cloud measuring radar are studied systematically.Radar block diagram and main parameters are presented.Antenna subsystem scheme is analyzed and antenna parameters are proposed.Central electronic device subsystem scheme is given and data rate of spaceborne radar is calculated.This paper is a meaningful try for carrying out spaceborne rain and cloud measuring radar design,acting as a reference to Chinese spaceborne rain and cloud measuring radar design and production in future.展开更多
The castings defects are affected by the melting volume change rate of material. The change rate has an important effect on running safety of the high temperature thermal storage chamber, too. But the characteristics ...The castings defects are affected by the melting volume change rate of material. The change rate has an important effect on running safety of the high temperature thermal storage chamber, too. But the characteristics of existing measuring installations are complex structure, troublesome operation and low precision. In order to measure the melting volume change rate of material accurately and conveniently, a self-designed measuring instrument, self-heating probe instrument, and measuring method are described. Temperature in heating cavity is controlled by PID temperature controller; melting volume change rate υ and molten density are calculated based on the melt volume which is measured by the instrument. Positive and negative υ represent expansion and shrinkage of the sample volume after melting, respectively. Taking eutectic LiF+CaF2 for example, its melting volume change rate and melting density at 1 123 K are -20.6% and 2 651 kg/m–3 measured by this instrument, which is only 0.71% smaller than literature value. Density and melting volume change rate of industry pure aluminum at 973 K and analysis pure NaCl at 1 123 K are detected by the instrument too. The measure results are agreed with report values. Measuring error sources are analyzed and several improving measures are proposed. In theory, the measuring errors of the change rate and molten density which are measured by the self-designed instrument is nearly 1/20-1/50 of that measured by the refitted mandril thermal expansion instrument. The self-designed instrument and method have the advantages of simple structure, being easy to operate, extensive applicability for material, relatively high accuracy, and most importantly, temperature and sample vapor pressure have little effect on the measurement accuracy. The presented instrument and method solve the problems of complicated structure and procedures, and large measuring errors for the samples with high vapor pressure by existing installations.展开更多
Comparing with the coordinates measuring machine (CMM),the theodolite industrial measuring system (TIMS) can be easily moved and it can measure large sized industrial targets contactlessly.But up to now the precision...Comparing with the coordinates measuring machine (CMM),the theodolite industrial measuring system (TIMS) can be easily moved and it can measure large sized industrial targets contactlessly.But up to now the precision of the TIMS has been considered so low that the TIMS isnt applied to some precise measurements.The error in self locating TIMS is a main factor which affects the precision of the TIMS.A new model of the TIMS is given out in this paper,and it can eliminate the error in self locating the TIMS.The new model is not only investigated and analyzed theoretically but also verified by the real measured data.展开更多
By using principal component analysis,this paper had modified and put forward a theoretical model of evaluation on tourist satisfaction degree with tourist perception quality and tourist satisfaction degree as structu...By using principal component analysis,this paper had modified and put forward a theoretical model of evaluation on tourist satisfaction degree with tourist perception quality and tourist satisfaction degree as structure variables and with thirty indexes like image of tourist area,tourists' expectation,infrastructure in tourist area,landscape features and ticket price as observed variables,based on random questionnaire survey of tourists of Zhenyuan ancient city in Guizhou Province and the existing evaluation models of tourist satisfaction degree at home and abroad.The survey result showed that tourist satisfaction degree was not high,that tourists were dissatisfied with observing facilities,transportation,accommodation and landscape features,and that the attraction power of tourist area was weak.The comprehensive tourist satisfaction degree of Zhenyuan ancient city was 77.653.Therefore,the government should enhance reconstruction of infrastructure and construction of landscape features,and improve tourist service quality level,so as to realize sustainable development of tourist economy in Zhenyuan ancient city.展开更多
According to the structural characteristics of gently inclined thin layer rock mass in which lots of weak interlayer existed,the concept of gently inclined thin layer weakness structure was proposed.If single-borehole...According to the structural characteristics of gently inclined thin layer rock mass in which lots of weak interlayer existed,the concept of gently inclined thin layer weakness structure was proposed.If single-borehole measuring method of the acoustic along the conventional arrangement mode was used in measuring the broken rock zone in this structure,the change of the relationship curves (Vp-L) between acoustic p-wave velocity (Vp) and borehole depth (L) would present the irregular feature due to the mechanical characteristics of layered rock mass and harmful effects of weak interlayers,and the scope of broken rock zone couldn't be defined quickly.Based on the analysis of the me- chanical characteristics of layered rock mass,the propagation rule of acoustic and distri- butions characteristics of plastic zone and slip zone in layered rock mass,new arrange- ment mode of acoustic measuring boreholes for broken rock zone in gently inclined thin layer weakness structure was proposed.Namely,the measuring boreholes in two sides were parallel to the strata,the measuring boreholes in the roof and floor perpendicular to the strata.Besides the controlling depth of the measuring boreholes in the scope of the large plastic zones or the large slip zones should be increased.Engineering example showed that new acoustic measuring boreholes arrangement mode had the better appli- cability and could determine the scope of the broken rock zone in the gently inclined thin layer weakness structure quickly.展开更多
The increase of quality consciousness brings about the growth of significance of metrological systems. Besides the significance, the level of automatization, flexibility, accuracy, et al. have advanced. The modern mea...The increase of quality consciousness brings about the growth of significance of metrological systems. Besides the significance, the level of automatization, flexibility, accuracy, et al. have advanced. The modern measuring systems are constructed so that nearly all necessary dimensional characteristics can be measured with them. However, conventional measuring systems are provided for particular mode measurements. This research paper presents and compares several conventional and modem measuring systems and methods. The measured value is roundness, one of the basic shapes of cross section in mechanical engineering. This paper arises in search of answers for the question whether conventional measuring techniques and equipments are made redundant because of the modern ones. In what segments and in which criterion are modem methods preferable?展开更多
In many situations such as the cores of a rotating electrical machine and the T joints of a multiphase transformer, the local flux density varies with time in terms of both magnitude and direction, i.e. the flux densi...In many situations such as the cores of a rotating electrical machine and the T joints of a multiphase transformer, the local flux density varies with time in terms of both magnitude and direction, i.e. the flux density vector is rotating. Therefore, the magnetic properties of the core materials under the rotating flux density vector excitation should be properly measured, modeled and applied in the design and analysis of these electromagnetic devices. This paper presents an extensive review on the development of techniques and apparatus for measuring the rotational core losses of soft magnetic materials based on the experiences of various researchers in the last hundred years.展开更多
A high precision, high antijamming multipoint infrared telemetry system was developed to measure the piston temperature in internal combustion engine. The temperature at the measuring point is converted into correspon...A high precision, high antijamming multipoint infrared telemetry system was developed to measure the piston temperature in internal combustion engine. The temperature at the measuring point is converted into corresponding voltage signal by the thermo-couple first. Then after the V/F stage, the voltage signal is converted into the frequency signal to drive the infrared light-emitting diode to transmit infrared pulses. At the receiver end, a photosensitive audion receives the infrared pulses. After conversion, the voltage recorded by the receiver stands for the magnitude of temperature at the measuring point. Test results of the system indicate that the system is practical and the system can perform multipoint looping temperature measurements for the piston.展开更多
文摘The machining process remains relevant for manufacturing high-quality and high-precision parts,which can be found in industries such as aerospace and aeronautical,with many produced by turning,drilling,and milling processes.Monitoring and analyzing tool wear during these processes is crucial to assess the tool’s life and optimize the tool’s performance under study;as such,standards detail procedures to measure and assess tool wear for various tools.Measuring wear in machining tools can be time-consuming,as the process is usually manual,requiring human interaction and judgment.In the present work,an automated offline flank wear measurement algorithm was developed in Python.The algorithm measures the flank wear of coated end-mills and slot drills from Scanning Electron Microscopy(SEM)images,according to the ISO 8688 standard,following the same wear measurement procedure.SEM images acquired with different magnifications and tools with varying machining parameters were analyzed using the developed algorithm.The flank wear measurements were then compared to the manually obtained,achieving relative errors for the most common magnifications of around 2.5%.Higher magnifications were also tested,yielding a maximum relative error of 13.4%.The algorithm can measure batches of images quickly on an ordinary personal computer,analyzing and measuring a 10-image batch in around 30 s,a process that would require around 30 min when performed manually by a skilled operator.Therefore,it can be a reliable alternative to measuring flank wear on many tools from SEM images,with the possibility of being adjusted for other wear measurements on different kinds of tools and different image types,for example,on images obtained by optical microscopy.
基金support from the National Natural Science Foundation of China(Grant Nos.12172332,11727803 and 12072009)the Zhejiang Provincial Natural Science Foundation of China(Grant No.LZ23A020007)the Fundamental Research Funds for the Provincial Universities of Zhejiang(Grant No.RF-C2022003).
文摘The presence of residual stresses in materials or engineering structures can significantly influence their mechanical per-formance.Accurate measurement of residual stresses is of great importance to ensure their in-service reliability.Although numerous instrumented indentation methods have been proposed to evaluate residual stresses,the majority of them require a stress-free reference sample as a comparison benchmark,thereby limiting their applicability in scenarios where obtaining stress-free reference samples is challenging.In this work,through a number of finite element simulations,it was found that the loading exponent of the loading load-depth curve and the recovered depth during unloading are insensitive to residual stresses.The loading curve of the stress-free specimen was virtually reconstructed using such stress-insensitive parameters extracted from the load-depth curves of the stressed state,thus eliminating the requirement for stress-free reference samples.The residual stress was then correlated with the fractional change in loading work between stressed and stress-free loading curves through dimensional analysis and finite element simulations.Based on this correlation,an instrumented sharp indentation method for measuring equibiaxial residual stress without requiring a stress-free specimen was established.Both numerical and experimental verifications were carried out to demonstrate the accuracy and reliability of the newly proposed method.The maximum relative error and absolute error in measured residual stresses are typically within±20%and±20 MPa,respectively.
基金Supported by the Key Research and Development Program of Anhui Province(No.201904a05020035)the Postdoctoral Research Initiative of Anhui Province(No.2024B804)the Hefei City Key Technology Research and Development‘Ranking’(No.2023SGJ017).
文摘Traditional automated guided vehicle(AGV)primarily relies on scheduling systems to manage warehouse locations and execute picking or placing tasks on fixedheight pallets.However,these conventional systems are illsuited for scenarios involving variable heights,such as vehicle loading and unloading or the complex stacking of soft packages.To address the challenges of AGV endeffector operations in nonfixed height scenarios,this paper proposes an innovative solution leveraging lowcost depth camera sensors.By capturing image and depth data,and integrating deep learning,image processing,and spatial attitude calculation techniques,the method accurately determines the position of the endeffector center point relative to the upper plane of the fork.The approach effectively resolves a key issue in AGV operations within intelligent logistics scenarios that lack fixed heights.The proposed algorithm is deployed on a domestic embedded,lowcost ARM chip controller,and extensive experiments are conducted on a real AGV equipped with multiple stacked vehicles and nonstandard vehicles.The experimental results demonstrate that for diverse vehicles with different heights,the measurement error can be maintained within±10 mm,satisfying the requirements for highprecision measurement.The height measurement method developed in the paper not only enhances the AGV’s adaptability in nonfixed height scenarios but also significantly broadens its application potential across various industries.
基金supported by the National Natural Science Foundation of China(Grant No.52125307)the National Key R&D Program of China(Grant No.2021YFB3501500)the support from the New Cornerstone Science Foundation through the XPLORER PRIZE。
文摘Rapid technological advancements drive miniaturization and high energy density in devices,thereby increasing nanoscale thermal management demands and urging development of higher spatial resolution technologies for thermal imaging and transport research.Here,we introduce an approach to measure nanoscale thermal resistance using in situ inelastic scanning transmission electron microscopy.By constructing unidirectional heating flux with controlled temperature gradients and analyzing electron energy-loss/gain signals under optimized acquisition conditions,nanometer-resolution in mapping phonon apparent temperature is achieved.Thus,interfacial thermal resistance is determined by calculating the ratio of interfacial temperature difference to bulk temperature gradient.This methodology enables direct measurement of thermal transport properties for atomic-scale structural features(e.g.,defects and heterointerfaces),resolving critical structure-performance relationships,providing a useful tool for investigating thermal phenomena at the(sub-)nanoscale.
基金supported by the Project of State Grid Hebei Electric Power Co.,Ltd.(SGHEYX00SCJS2100077).
文摘Crop water stress index(CWSI)is widely used for efficient irrigation management.Precise canopy temperature(T_(c))measurement is necessary to derive a reliable CWSI.The objective of this research was to investigate the influences of atmospheric conditions,settled height,view angle of infrared thermography,and investigating time of temperature measuring on the performance of the CWSI.Three irrigation treatments were used to create different soil water conditions during the 2020-2021 and 2021-2022 winter wheat-growing seasons.The CWSI was calculated using the CWSI-E(an empirical approach)and CWSI-T(a theoretical approach)based on the T_(c).Weather conditions were recorded continuously throughout the experimental period.The results showed that atmospheric conditions influenced the estimation of the CWSI;when the vapor pressure deficit(VPD)was>2000 Pa,the estimated CWSI was related to soil water conditions.The height of the installed infrared thermograph influenced the T_(c)values,and the differences among the T_(c)values measured at height of 3,5,and 10 m was smaller in the afternoon than in the morning.However,the lens of the thermometer facing south recorded a higher T_(c)than those facing east or north,especially at a low height,indicating that the direction of the thermometer had a significant influence on T_(c).There was a large variation in CWSI derived at different times of the day,and the midday measurements(12:00-15:00)were the most reliable for estimating CWSI.Negative linear relationships were found between the transpiration rate and CWSI-E(R^(2)of 0.3646-0.5725)and CWSI-T(R^(2)of 0.5407-0.7213).The relations between fraction of available soil water(FASW)with CWSI-T was higher than that with CWSI-E,indicating CWSI-T was more accurate for predicting crop water status.In addition,The R^(2)between CWSI-T and FASW at 14:00 was higher than that at other times,indicating that 14:00 was the optimal time for using the CWSI for crop water status monitoring.Relative higher yield of winter wheat was obtained with average seasonal values of CWSI-E and CWSI-T around 0.23 and 0.25-0.26,respectively.The CWSI-E values were more easily influenced by meteorological factors and the timing of the measurements,and using the theoretical approach to derive the CWSI was recommended for precise irrigation water management.
基金supported by the National Natural Science Foundation of China(Nos.52005413,52022082)Natural Science Basic Research Plan in Shaanxi Province of China(No.2021JM-054)the Fundamental Research Funds for the Central Universities(No.D5000220135)。
文摘Geometric error,mainly due to imperfect geometry and dimensions of machine components,is one of the major error sources of machine tools.Considering that geometric error has significant effects on the machining quality of manufactured parts,it has been a popular topic for academic and industrial research for many years.A great deal of research work has been carried out since the 1970s for solving the problem and improving the machining accuracy.Researchers have studied how to measure,detect,model,identify,reduce,and compensate the geometric errors.This paper presents a thorough review of the latest research activities and gives an overview of the state of the art in understanding changes in machine tool performance due to geometric errors.Recent advances in measuring the geometrical errors of machine tools are summarized,and different kinds of error identification methods of translational axes and rotation axes are illustrated respectively.Besides,volumetric geometric error modeling,tracing,and compensation techniques for five-axis machine tools are emphatically introduced.Finally,research challenges in order to improve the volumetric accuracy of machine tools are also highlighted.
基金supported by the National Key Research and Development Program of China(No.2023YFC2907600)the National Natural Science Foundation of China(Nos.42077267,42277174 and 52074164)+2 种基金the Natural Science Foundation of Shandong Province,China(No.ZR2020JQ23)the Opening Project of State Key Laboratory of Explosion Science and Technology,Beijing Institute of Technology(No.KFJJ21-02Z)the Fundamental Research Funds for the Central Universities,China(No.2022JCCXSB03).
文摘The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 92065113, 11904357, 62075208, and 12174367)the Innovation Programme for Quantum Science and Technology (Grant No. 2021ZD0301604)+1 种基金the National Key Research and Development Program of China (Grant No. 2021YFE0113100)supported by Beijing Academy of Quantum Information Sciences
文摘Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted into phase signals,it is interesting and important to consider measuring small longitudinal phase shifts by using weak measurement.Here,we propose and experimentally demonstrate a novel weak measurement amplification-based small longitudinal phase estimation,which is suitable for polarization interferometry.We realize one order of magnitude amplification measurement of a small phase signal directly introduced by a liquid crystal variable retarder and show that it is robust to the imperfection of interference.Besides,we analyze the effect of magnification error which is never considered in the previous works,and find the constraint on the magnification.Our results may find important applications in high-precision measurements,e.g.,gravitational wave detection.
文摘The research on gas-liquid multiphase reactions using micro reactors is becoming increasingly widespread, given their excellent mass transfer performance. Establishing an accurate and reliable method to measure the gas-liquid mass transfer performance of micro reactors is crucial for evaluating and optimizing the design of micro reactor structure. In this paper, the physical absorption method of aqueous solution-CO_(2) and the chemical absorption method of sodium carbonate solution-CO_(2) were proposed. By analyzing the chemical reaction equilibrium during the absorption process, the relationship between the mass transfer of CO_(2) and the solubility of hydroxide ions in the solution was established, and the total gas-liquid mass transfer coefficient was immediately obtained by measuring the p H value. The corresponding testing platform and process have been established based on the characteristics of the proposed method to ensure fast and accurate measurement. In addition, the chemical absorption method takes into account temperature factors that were not previously considered. The volumetric mass transfer coefficient measured by these two methods is in the same range as those measured by other methods using the same microchannel structure in previous literature. The methods have the advantages of low equipment cost, faster measurement speed, and simpler procedures, which can facilitate its wide application to the evaluation of the mass transfer performance and hence can guide the structure optimization of microchannel reactors.
文摘BACKGROUND To avoid acute variceal bleeding in cirrhosis,current guidelines recommend screening for high-risk esophageal varices(EVs)by determining variceal size and identifying red wale markings.However,visual measurements of EV during routine endoscopy are often inaccurate.AIM To determine whether biopsy forceps(BF)could be used as a reference to improve the accuracy of binary classification of variceal size.METHODS An in vitro self-made EV model with sizes ranging from 2 to 12 mm in diameter was constructed.An online image-based survey comprising 11 endoscopic images of simulated EV without BF and 11 endoscopic images of EV with BF was assembled and sent to 84 endoscopists.The endoscopists were blinded to the actual EV size and evaluated the 22 images in random order.RESULTS The respondents included 48 academic and four private endoscopists.The accuracy of EV size estimation was low in both the visual(13.81%)and BF-based(20.28%)groups.The use of open forceps improved the ability of the endoscopists to correctly classify the varices by size(small≤5 mm,large>5 mm)from 71.85%to 82.17%(P<0.001).CONCLUSION BF may improve the accuracy of EV size assessment,and its use in clinical practice should be investigated.
文摘The analysis and calculating method of dynamic errors of CMMs during probing are discussed.To relate the dynamic displacement errors with the dynamic rotational errors a method for obtaining the displacement errors at the probing position from dynamic rotational errors is presented.It is pointed out that the finite element method might be used for modeling dynamic errors.However,dynamic errors are difficult to be modeled so a combined practical and theoretical approach is needed.In addition,the dynamic errors are measured with inductive position sensors.
基金Supported by Horizontal Program of Space Long March Rocket Technology Co. Ltd (500036)
文摘Dual-frequency and multi-polarization spaceborne rain and cloud measuring radar is the inevitable trend of remote sensing techniques.Techniques of new generation dual-frequency and multi-polarization spaceborne rain and cloud measuring radar are studied systematically.Radar block diagram and main parameters are presented.Antenna subsystem scheme is analyzed and antenna parameters are proposed.Central electronic device subsystem scheme is given and data rate of spaceborne radar is calculated.This paper is a meaningful try for carrying out spaceborne rain and cloud measuring radar design,acting as a reference to Chinese spaceborne rain and cloud measuring radar design and production in future.
基金supported by Gansu Provincial Critical Patented Projects of China(Grant No. 1101ZSB117)Gansu Provincial Science and Technology Pillar Program of China(Grant No. 1002ZSB018)
文摘The castings defects are affected by the melting volume change rate of material. The change rate has an important effect on running safety of the high temperature thermal storage chamber, too. But the characteristics of existing measuring installations are complex structure, troublesome operation and low precision. In order to measure the melting volume change rate of material accurately and conveniently, a self-designed measuring instrument, self-heating probe instrument, and measuring method are described. Temperature in heating cavity is controlled by PID temperature controller; melting volume change rate υ and molten density are calculated based on the melt volume which is measured by the instrument. Positive and negative υ represent expansion and shrinkage of the sample volume after melting, respectively. Taking eutectic LiF+CaF2 for example, its melting volume change rate and melting density at 1 123 K are -20.6% and 2 651 kg/m–3 measured by this instrument, which is only 0.71% smaller than literature value. Density and melting volume change rate of industry pure aluminum at 973 K and analysis pure NaCl at 1 123 K are detected by the instrument too. The measure results are agreed with report values. Measuring error sources are analyzed and several improving measures are proposed. In theory, the measuring errors of the change rate and molten density which are measured by the self-designed instrument is nearly 1/20-1/50 of that measured by the refitted mandril thermal expansion instrument. The self-designed instrument and method have the advantages of simple structure, being easy to operate, extensive applicability for material, relatively high accuracy, and most importantly, temperature and sample vapor pressure have little effect on the measurement accuracy. The presented instrument and method solve the problems of complicated structure and procedures, and large measuring errors for the samples with high vapor pressure by existing installations.
文摘Comparing with the coordinates measuring machine (CMM),the theodolite industrial measuring system (TIMS) can be easily moved and it can measure large sized industrial targets contactlessly.But up to now the precision of the TIMS has been considered so low that the TIMS isnt applied to some precise measurements.The error in self locating TIMS is a main factor which affects the precision of the TIMS.A new model of the TIMS is given out in this paper,and it can eliminate the error in self locating the TIMS.The new model is not only investigated and analyzed theoretically but also verified by the real measured data.
基金Supported by Planning Project of Kaili Institute(Z1009)and Youth Foundation of Special Scientific Research Project of Key Discipline of Tourist Management of Kaili Institute(lgz200904)~~
文摘By using principal component analysis,this paper had modified and put forward a theoretical model of evaluation on tourist satisfaction degree with tourist perception quality and tourist satisfaction degree as structure variables and with thirty indexes like image of tourist area,tourists' expectation,infrastructure in tourist area,landscape features and ticket price as observed variables,based on random questionnaire survey of tourists of Zhenyuan ancient city in Guizhou Province and the existing evaluation models of tourist satisfaction degree at home and abroad.The survey result showed that tourist satisfaction degree was not high,that tourists were dissatisfied with observing facilities,transportation,accommodation and landscape features,and that the attraction power of tourist area was weak.The comprehensive tourist satisfaction degree of Zhenyuan ancient city was 77.653.Therefore,the government should enhance reconstruction of infrastructure and construction of landscape features,and improve tourist service quality level,so as to realize sustainable development of tourist economy in Zhenyuan ancient city.
基金the National Natural Science Foundation of China(50490274)National Key Project of Scientific and Technical Supporting Programs of China(2006BAB02A02)Guangxi University Research Foundation(X061068)
文摘According to the structural characteristics of gently inclined thin layer rock mass in which lots of weak interlayer existed,the concept of gently inclined thin layer weakness structure was proposed.If single-borehole measuring method of the acoustic along the conventional arrangement mode was used in measuring the broken rock zone in this structure,the change of the relationship curves (Vp-L) between acoustic p-wave velocity (Vp) and borehole depth (L) would present the irregular feature due to the mechanical characteristics of layered rock mass and harmful effects of weak interlayers,and the scope of broken rock zone couldn't be defined quickly.Based on the analysis of the me- chanical characteristics of layered rock mass,the propagation rule of acoustic and distri- butions characteristics of plastic zone and slip zone in layered rock mass,new arrange- ment mode of acoustic measuring boreholes for broken rock zone in gently inclined thin layer weakness structure was proposed.Namely,the measuring boreholes in two sides were parallel to the strata,the measuring boreholes in the roof and floor perpendicular to the strata.Besides the controlling depth of the measuring boreholes in the scope of the large plastic zones or the large slip zones should be increased.Engineering example showed that new acoustic measuring boreholes arrangement mode had the better appli- cability and could determine the scope of the broken rock zone in the gently inclined thin layer weakness structure quickly.
文摘The increase of quality consciousness brings about the growth of significance of metrological systems. Besides the significance, the level of automatization, flexibility, accuracy, et al. have advanced. The modern measuring systems are constructed so that nearly all necessary dimensional characteristics can be measured with them. However, conventional measuring systems are provided for particular mode measurements. This research paper presents and compares several conventional and modem measuring systems and methods. The measured value is roundness, one of the basic shapes of cross section in mechanical engineering. This paper arises in search of answers for the question whether conventional measuring techniques and equipments are made redundant because of the modern ones. In what segments and in which criterion are modem methods preferable?
文摘In many situations such as the cores of a rotating electrical machine and the T joints of a multiphase transformer, the local flux density varies with time in terms of both magnitude and direction, i.e. the flux density vector is rotating. Therefore, the magnetic properties of the core materials under the rotating flux density vector excitation should be properly measured, modeled and applied in the design and analysis of these electromagnetic devices. This paper presents an extensive review on the development of techniques and apparatus for measuring the rotational core losses of soft magnetic materials based on the experiences of various researchers in the last hundred years.
文摘A high precision, high antijamming multipoint infrared telemetry system was developed to measure the piston temperature in internal combustion engine. The temperature at the measuring point is converted into corresponding voltage signal by the thermo-couple first. Then after the V/F stage, the voltage signal is converted into the frequency signal to drive the infrared light-emitting diode to transmit infrared pulses. At the receiver end, a photosensitive audion receives the infrared pulses. After conversion, the voltage recorded by the receiver stands for the magnitude of temperature at the measuring point. Test results of the system indicate that the system is practical and the system can perform multipoint looping temperature measurements for the piston.